Omron Blood Pressure Monitor M3W User Manual

OMRON HEALTHCARE Co., Ltd.  
53, Kunotsubo, Terado-cho, Muko, Kyoto,  
617-0002 JAPAN  
Manufacturer  
Check following components!  
Vérifier les composants suivants !  
Controleer de volgende onderdelen!  
Prüfen Sie folgende Teile des Lieferumfangs! Проверьте следующие компоненты!  
Controllare i componenti indicati di seguito!  
¡Compruebe los siguientes componentes!  
EU-representative  
OMRON HEALTHCARE EUROPE B.V.  
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS  
Production facility  
Site de production  
Planta de producción  
Productiefaciliteit  
OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD.  
Binh Duong Province, VIETNAM  
Herstellungswerk  
Stabilimento di produzione  
Производственное подразделение  
English  
Français  
Deutsch  
Italiano  
Subsidiary  
Empresa filial  
Dochteronderneming  
Филиал  
OMRON HEALTHCARE UK LTD.  
Opal Drive  
Succursale  
Niederlassung  
Consociata  
Fox Milne, Milton Keynes, MK15 0DG, U.K.  
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH  
John-Deere-Str. 81a, 68163 Mannheim, GERMANY  
OMRON SANTÉ FRANCE SAS  
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE  
Uniquement pour le marché français:  
OMRON Service Après Vente  
N° Vert 0 800 91 43 14  
Español  
Nederlands  
Русский  
Digital Automatic Blood Pressure Monitor  
Model M3W  
Eng  
lish  
Français  
Dig  
Deu  
tsc  
ital  
A
h
utom  
atic  
Mo  
ct  
B
del  
io  
Italia  
loo  
M3W  
d
P
ress  
no  
ure  
Moni  
tor  
Esp  
Ned  
añ  
ol  
erland  
Ins  
tru  
n
Ma  
nu  
al  
s
Ру  
сский  
IM-HEM  
-7202  
-E(V)  
5334  
-02-0  
060-6  
1/2012  
B
Instruction Manual  
IM-HEM-7202-E(V)-02-01/2012  
5334060-6B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Information  
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis.  
Please read this section carefully before using the unit.  
Warning:  
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  
(General Usage)  
• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.  
• People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff  
inflation can cause internal bleeding.  
(AC Adapter Usage)  
• Never plug in or unplug the power cord from the electric outlet with wet hands.  
(Battery Usage)  
EN  
• If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.  
Caution:  
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user  
or patient or damage to the equipment or other property.  
(General Usage)  
• Do not leave the unit unattended with infants or persons who cannot express their consent.  
• Do not use the unit for any purpose other than measuring blood pressure.  
• Do not disassemble the unit or arm cuff.  
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.  
• Make sure that the air tube is not wrapped around other parts of your body when taking measurements. This could  
result in injury when the air pressure in the air tube is increased.  
• Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in injury.  
• Do not inflate the arm cuff over 299 mmHg.  
• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in  
incorrect operation of the unit.  
• Do not operate the unit in a moving vehicle (car, airplane).  
To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it can cause internal bleeding.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Information  
(AC Adapter Usage)  
• Use only the original AC adapter (optional) designed for this unit. Use of unsupported adapters may damage and/or  
may be hazardous to the unit.  
• Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap.  
• Do not use the AC adapter if the unit or the power cord is damaged. Turn off the power and unplug the power cord  
immediately.  
(Battery Usage)  
• If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.  
• Use only four “AA” alkaline or manganese batteries with this unit. Do not use other types of batteries.  
• Do not insert the batteries with their polarities incorrectly aligned.  
• Replace old batteries with new ones immediately. Replace all four batteries at the same time.  
• Remove the batteries if the unit will not be used for three months or more.  
• Do not use new and used batteries together.  
General Precautions  
• Do not apply strong shocks and vibrations to or drop the unit and arm cuff.  
• Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating.  
• Do not forcibly bend the arm cuff or bend the air tube excessively.  
• When removing the air tube, pull on the air plug at the connection with the main unit not the tube itself.  
• Do not inflate the arm cuff when it is not wrapped around your arm.  
• Do not wash the arm cuff or immerse it in water.  
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data  
Section.  
• Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device  
and any used accessories or optional parts.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Overview  
Open the rear cover page to read following:  
The alphabet in the rear cover page correspond to those in the body page.  
Main unit  
Display  
A
B
C
D
E
M
Display  
Systolic blood pressure  
N
O
O/I START ( ) button  
User A/B button  
Up/Down (  
Diastolic blood pressure  
Heartbeat symbol  
(Flashes during measurement)  
EN  
) buttons  
P
Q
R
S
T
Average value symbol  
Deflation symbol  
Buzzer and Date/Time setting  
( ) button  
Memory symbol  
F
G
H
Air Jack  
Irregular heartbeat symbol  
Movement error symbol  
Blood pressure level indicator  
Pulse display and Memory  
number  
Battery compartment  
AC adapter jack (for optional AC  
adapter)  
U
V
Arm cuff  
I
Arm cuff (Wide Range Cuff: arm  
W
X
Y
Z
AA  
Buzzer symbol  
circumference 22-42cm)  
Cuff wrapping guide  
USER ID symbol (A/B)  
Battery low symbol  
Date/Time display  
J
K
L
Marker  
Air tube  
Air plug  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Preparation  
2.1 Installing/Replacingthe  
Batteries  
1. Remove the battery cover.  
2. Insert four “AA” batteries as  
indicated in the battery  
compartment and then replace the battery cover.  
Notes:  
• If the battery low symbol (  
time.  
) appears on the display, turn the unit off then replace all batteries at the same  
• The measurement values continue to be stored in memory even after the batteries are replaced.  
Disposal of used batteries should be carried out in accordance with the national  
regulations for the disposal of batteries.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Preparation  
2.2 Setting the Buzzer/ Date and Time  
1. Press the button.  
2. Set the Buzzer.  
Push  
select On or Off.  
or  
buttons to  
1)  
2)  
EN  
Push the  
button to confirm.  
Off  
On  
3. Set the monitor to the correct date and time before  
taking a measurement for the first time.  
Push  
change.  
or  
buttons to  
1)  
Push the  
Next setting appears.  
button to confirm.  
2)  
Year  
Month  
Day  
Hour  
Minute  
4. Press the O/I START button to store the setting.  
Notes:  
• If the batteries have been removed for 30 seconds or more, the date and time setting will need to be reset.  
• If the date and time are not set, “-:--” appears during or after measurement.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
Open both the front and rear covers to read following:  
The alphabet and number in the cover page correspond to those in the body page.  
3.1 Applying the Arm Cuff  
Remove tight-fitting clothing or tight rolled up sleeve from your upper arm.  
Do not place the cuff over thick clothes.  
L
F
1. Insert the air plug into the air jack.  
2. Put your arm through the cuff loop.  
3. Position the arm correctly.  
J
a
The bottom edge of the cuff should be  
under tube) is centred on the middle of your inner arm. Close the fabric fastener FIRMLY.  
1 to 2 cm above the elbow.  
Marker (arrow  
Notes:  
• When you take a measurement on the right arm, air tube will be at the side of your elbow. Be careful not  
to rest your arm on the air tube. ---  
b
• The blood pressure can differ between the right arm and the left arm, and therefore also the measured  
blood pressure values can be different. OMRON recommends to always use the same arm for  
measurement. If the values between the two arms differ substantially, please check with your physician  
which arm to use for your measurement.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
3.2 How to Sit Correctly  
To take a measurement, you need to be relaxed and comfortably seated, under  
comfortable room temperature. No eating, smoking or exercising 30 minutes before  
taking a measurement.  
• Sit on a chair with your feet flat on the floor.  
c
• Sit upright with your back straight. ---  
d
• The cuff should be at the same level as your heart. ---  
EN  
Cuff wrapping guide  
The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around  
the arm. Even when the  
is displayed, a blood pressure reading will be taken.  
Note:  
This reading is NOT reliable due to the incorrect wrapping of the cuff. Please wrap the cuff again, taking  
care to wrap it correctly and take the measurement again.  
When the  
is displayed, the cuff is correctly wrapped tightly enough on the arm and the reading is  
accurate and reliable.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
3.3 Taking a Reading  
Notes:  
To cancel a measurement, press the O/I START button to turn off the unit and to release the air in the arm cuff.  
• Remain still while taking a measurement.  
The monitor is designed to take measurements and store the measurement values in  
the memory for two people using USER ID A and USER ID B.  
1. Press the O/I START button.  
2. Select your USER ID (A or B).  
3. Press the O/I START button again.  
The cuff will start to inflate automatically.  
The buzzer will sound when measurement is completed.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
If your systolic pressure is  
more than 220 mmHg  
START  
INFLATE  
DEFLATE  
END  
COMPLETE  
After the cuff starts to inflate, press and hold  
the O/I START button until the monitor  
inflates 30 to 40 mmHg higher than your  
expected systolic pressure.  
Notes:  
EN  
• The monitor will not inflate above 299 mmHg.  
• Do not apply more pressure than necessary.  
Notes:  
• During measurement, the buzzer (if set to “on”) will beep in rhythm with your heartbeat.  
• Wait 2-3 minutes before taking another blood pressure measurement. Waiting between readings allows the  
arteries to return to the condition prior to taking the blood pressure measurement.  
Warning:  
Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of  
your doctor.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
4. Remove the arm cuff.  
5. Press the O/I START button to turn off the monitor.  
The monitor automatically stores the measurement in its memory.  
It will automatically turn off after five minutes.  
Important:  
• Recent research suggests that the following values can be used as a guide to  
high blood pressure for measurements taken at home.  
Systolic Blood Pressure  
Above 135 mmHg  
Diastolic Blood Pressure Above 85 mmHg  
This criteria is for home blood pressure measurement.  
For professional office blood pressure measurement criteria, please refer to  
Chapter 7.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
• Your blood pressure monitor includes an irregular heartbeat feature. Irregular heartbeats  
can influence the results of the measurement. The irregular heartbeat algorithm  
automatically determines if the measurement is usable or needs to be repeated. If the  
measurement results are affected by irregular heartbeats but the result is valid, the result is  
shown together with the irregular heartbeat symbol (  
). If the irregular heartbeats cause  
the measurement to be invalid, no result is shown. If the irregular heartbeat symbol (  
is shown after you have taken a measurement, repeat the measurement. If the irregular  
)
heartbeat symbol (  
) is shown frequently, please make your doctor aware of it.  
• If you move during measurement, the movement error symbol ( ) will appear on the  
display. Keep still and repeat the measurement.  
EN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
3.4 Using the Memory Function  
The monitor automatically stores the result up to 60 sets for each user (A and B). It  
can also calculate an average reading based on the measurements from the last  
three readings taken within 10 minutes. If there are only two readings in memory for  
that period, the average will be based on two readings. If there is one reading in  
memory for that period, the average will be based on one reading.  
Notes:  
• If the memory is full, the monitor will delete the oldest readings.  
• When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date  
and time.  
To View the Average Value  
1. Press the or button.  
2. Select your USER ID (A or B).  
Note: If there are no measurements results stored in the memory, the  
screen to the right is displayed.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the Unit  
To View the Readings Stored in Memory  
1. Press the button, while the average value is displayed.  
The Memory number appears for a second  
before the pulse rate is displayed. The newest  
set is numbered “1”.  
Alternating date/  
time display  
EN  
2. Press the or button to view the readings stored in  
memory.  
: To the older readings  
: To the more recent readings  
To Delete All the Values Stored in Memory  
The values stored in the memory are deleted by USER ID.  
When the memory symbol ( ) appears, first press  
the  
button. Then while holding it down, press  
the O/I START button simultaneously for about 2-3  
seconds.  
Note: You cannot partially delete values stored in the memory.  
All values for the user you select will be deleted.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Troubleshooting and Maintenance  
4.1 The Icons and Error Messages  
Error Display  
Cause  
Remedy  
Remove the arm cuff. Wait 2-3 minutes and then  
take another measurement.  
Irregular or weak pulses are detected.  
Repeat the steps in section 3.3. If this error  
continues to appear, contact your doctor.  
Movement during measurement.  
Cuff is not applied correctly.  
Carefully read and repeat the steps in section 3.3.  
Apply the arm cuff correctly. Refer to section 3.1.  
You should replace them with new ones ahead of  
time.  
Refer to section 2.1.  
The batteries are low.  
Blink  
Lit  
You should replace them with new ones at once.  
Refer to section 2.1.  
The batteries are exhausted.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Troubleshooting and Maintenance  
Error Display  
Cause  
Remedy  
Carefully read and repeat the steps listed under  
section 3.3.  
Cuff is under inflated.  
Repeat measurement. Remain still and do not  
talk during measurement.  
Refer to section 3.3.  
Movement during measurement.  
Insert the air plug securely.  
Refer to section 3.1.  
EN  
Air plug disconnected.  
Apply the arm cuff correctly.  
Refer to section 3.1.  
Arm cuff not applied correctly.  
Clothing is interfering with the arm cuff.  
Air is leaking from the arm cuff.  
Remove any clothing interfering with the arm cuff.  
Refer to section 3.1.  
Replace cuff with new one.  
Refer to Chapter 5.  
Do not inflate the arm cuff above 299 mmHg.  
Refer to section 3.3.  
The arm cuff was inflated above 299  
mmHg when inflating the cuff manually.  
Device error.  
Contact your OMRON retail outlet or distributor.  
Note:  
The irregular heartbeat symbol (  
) may also be displayed with error messages.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Troubleshooting and Maintenance  
4.2 Troubleshooting  
Problem  
Cause  
Remedy  
Apply the arm cuff correctly.  
Refer to section 3.1.  
Arm cuff not applied correctly.  
Remain still and do not talk during  
measurement.  
Refer to section 3.3.  
Movement or talking during  
measurement.  
The reading is extremely low (or  
high).  
Remove any clothing interfering  
with the arm cuff.  
Refer to section 3.2.  
Clothing is interfering with the arm  
cuff.  
Make sure that the air tube is  
connected securely.  
Refer to section 3.1.  
The air tube is not securely  
connected into the main unit.  
Arm cuff pressure does not rise.  
Arm cuff deflates too soon.  
Replace the arm cuff with a new  
one.  
Refer to Chapter 5.  
Air is leaking from the arm cuff.  
The arm cuff is loose.  
Apply the cuff correctly so that it is  
firmly wrapped around the arm.  
Refer to section 3.1.  
Inflate the cuff so that it is 30 to  
40 mmHg above your previous  
measurement result.  
Cannot measure or readings are too  
low or too high.  
The arm cuff has not been inflated  
sufficiently.  
Refer to section 3.3.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Nikon Webcam NX D User Manual
Nintendo Video Games 45496902933 User Manual
Nokia Cell Phone NSD1 User Manual
Novatel Radio Antenna SMART V1 User Manual
NuTone Intercom System IA 28 User Manual
NuTone Ventilation Hood NP629004 User Manual
Oceanic Watch ATOM 20 User Manual
Omron Network Card CJ1W ETN11 User Manual
Opticon Scanner CRD972X User Manual
Panamax Car Stereo System M5300 EX User Manual