“CLB” DIP-Switch - Local Coax Mode Operation (Coax Loopback):
T3/E3 MODEL NUMBER REFERENCE CHART:
“FAIS” Force AIS to Fiber (Force 1’s to Fiber):
When the “FAIS” dip-switch is in the right position, an “all
FRONT PANEL DIP-SWITCH SETTINGS:
This DIP-switch facilitates the testing of the coax cables. When the “CLB”
dip-switch is in the right position, it sets the coax port to a Local Coax
Loopback Mode (Figure 4) and the “CLB” LED is turned ON. When in this
mode, data received at the BNC-In is forwarded to the BNC-Out and the
Fiber-Out. If no data is received at BNC-In, an AIS pattern is transmitted
out both BNC-Out and Fiber-Out. By returning the DIP-switch to the left
position, the unit resumes normal operation.
The following DIP-switches are located on the front of the T3/E3 converter.
These switches provide data path control (normal operation and loop-
backs) and test patterns (all 1’s) that assist in installation and fault isolation.
ones” pattern is forced out the Fiber-Out port. The Coax-In
data is discarded and Fiber-In data is passed through to
BNC-Out. By returning the dip-switch to the left position,
the unit resumes normal operation.
iConverter T3/E3 Coax Dual Fiber Modules
iConverter® T3/E3 User Manual
Connector Type
Fiber Type Distance
ST
SC
MT-RJ
LC
SFP
“CAIS” Force AIS to Coax (Force 1’s to Coax):
8759-0*
-
-
-
-
-
-
-
When the “CAIS” dip-switch is in the right position, an “all
ones” pattern is forced out the BNC-Out port. The Fiber-In
data is discarded and BNC-In data is passed through to
Fiber-Out. By returning the dip-switch to the left position,
the unit resumes normal operation.
MM
SM
SM
5 km
30 km
60 km
8740-0 8742-0 8744-0
-
-
-
8741-1 8743-1 8745-1 8747-1
8741-2 8743-2
8743-3
8747-2
8747-3
-
-
Fig. 1 Front Panel DIP-Switches
SM
120 km
-
-
Normal Mode Operation (Straight Through):
iConverter T3/E3 Coax Single-Fiber Modules
ON BOARD DIP-SWITCH SETTINGS:
The default DIP-switch setting (all dip-switches to the left) sets the converter
to its Normal Mode and allows data to flow straight through between the
BNC and Fiber ports (Figure 2).
Fig. 4 Coax Loopback and DIP-Switch Settings
Remote Loopback Mode:
Fiber /
Connector Distance
Type
[Switch
Position]
Function
Tx: 1310 nm,
Rx: 1550 nm
Tx: 1550 nm,
Rx: 1310 nm
Left
Position
Right
Position
Left Function
Right Function
T3 Selected
When both the “FLB” and “CLB” DIP-switches are in the right position, they
force a remote unit to loop back its fiber and coax ports (Figure 5). This
facilitates test of the fiber cables and the remote unit without having to
physically set DIP-switches on the remote unit. While in this mode, the
local unit’s BNC is set to a local loopback, and its “FLB” and “CLB” LEDs
are turned ON.
OVERVIEW:
SM / SC
SM / SC
20 km
40 km
8750-1
8750-2
8751-1
8751-2
[1]
T3 Select
OFF
(default)
-
T3
E3
The iConverter T3/E3 managed media converter is a member of the
modular iConverter product family. The T3/E3 provides standard T3
(B3ZS line protocol, 44.763Mbps) or E3 (HDB3 line protocol, 34.368Mbps)
coax to fiber conversion and can be used by telco service providers
and enterprise users to connect devices such as PBXs, multiplexers,
routers and video servers via multimode (MM), single-mode (SM) or
single-mode single-fiber (SF) fiber.
E3 is selected
when T3 and
STS-1 are OFF
For wide temperature (-40 to 60º C), add a "W" to the end of the model number.
Consult factory for extended temperature (-40 to 75º C) models.
When using single-fiber (SF) media converter models, the TX wavelength on one end
has to match the RX wavelength on the other.
[2]
E3 Select
OFF
(default)
E3 Selected
While in the Remote Loopback Mode, the local unit sends a test pattern to
the remote unit. This pattern forces the remote unit into the loopback mode
and is also returned back to the local unit. When forced into the Remote
Loopback Mode, the remote unit’s “FLB” and “CLB” blink slowly (1Hz).
[3]
OFF
(default)
-
STS-1
>225
STS-1 Selected
*See SFP data sheet under Fast Ethernet for supported transceiver models.
Fig. 2 Normal Mode and DIP-Switch Settings
STS-1 Select
“FLB” Dip-Switch - Local Fiber Mode Operation (Fiber Loopback):
[4]
Long distance,
equal-to or
more than 225ft
<225
Short distance,
Coax build-out
distance selection
Designed to extend the standard T3/E3 Coax network distances over
fiber, this converter provides protection from environmental noise and
effectively increases high-speed network reliability.
This DIP-switch facilitates the testing of the fiber cables. When the “FLB”
dip-switch is in the right position, it sets the fiber port to a Local Fiber
Loopback Mode (Figure 3) and the “FLB” LED is turned ON. When in this
mode, data received at the Fiber-In is forwarded to the BNC-out and the
Fiber-Out. If no data is received at Fiber-In, an AIS pattern is transmitted
out both BNC-Out and Fiber-Out. By returning the DIP-switch to the left
position, the unit resumes normal operation.
(default) less than 225ft.
When the test pattern is received successfully at the local unit’s Fiber-In,
the “TST” LED blinks rapidly (10Hz). Any other data causes slow “TST”
blinking (1Hz). If no data is returned to Fiber-In, the LED is turned OFF.
[5]
CEN
Coax port
enabled
Coax port
disabled [OFF]
CDIS
FDIS
Coax port control (default)
The T3/E3 module can be used in any of the iConverter chassis such
as the 1-Module, 2-Module, 5-Module and 19-Module chassis.
Returning both dip-switches to the left position, causes the local and
remote units to resume normal operation.
[6] FEN
Fiber port control (default)
Fiber port
enabled
Fiber port
disabled [OFF]
The T3/E3 can be used in a managed or unmanaged fashion. When
unmanaged, it can be installed in an iConverter chassis without a
Network Management Module (NMM). To be managed, a NMM module
must be installed in the same chassis as the T3/E3 module. To read
about specific management functionality, refer to the NetOutlook™
user manual T3/E3 section.
[7]
OFF
Force PRBS[1]
to BNC-Out
Force PRBS to
(default)
Normal data
PRBS
-
BNC-Out
8 = Reserved
-
-
-
Note: [1] Pseudo Random Bit Sequence [PRBS] is a data pattern
defined by ITU O.151 spec: E3: 2^23-1, T3: 2^15-1
This User Manual covers the models listed in the following table.
Fig. 5 Remote Loopback and DIP-Switch Settings
Fig. 3 Fiber Loopback and DIP-Switch Settings
Page 2
Page 1
Page 4
Page 5
Page 3
For warranty service, the product must be sent to an Omnitron desig-
nated facility, at Buyer’s expense. Omnitron will pay the shipping charge
to return the product to Buyer’s designated US address using Omnitron’s
standard shipping method.
The On Board DIP-switches facilitate the selection between T3, E3,
STS-1 protocols, the coax distance, fiber and coax port control and the
injection of pseudo random data patterns into the coax.
T3/E3 LED REFERENCE CHART:
T3/E3 SPECIFICATION CHART:
MOUNTING INSTRUCTIONS and CABLE ATTACHMENTS:
iConverter modules are hot-swappable and can be installed into any
chassis in the iConverter family.
Function
"Legend"
OFF
State
T3/E3
Model Type
Protocols
Color
ON / Blinking state
1. Carefully slide the iConverter module into the installation slot, aligning
the module with the installation guides. Ensure that module is firmly
seated against the backplane.
2. Secure the module by securing the panel fastener screw (attached to
module) to chassis front.
3. When using an SFP model (8759-0), insert the SFP Fiber transceiver
into the SFP receptacle on the module.
Note: The release latch of the SFP Fiber transceiver must be in
the closed position before insertion.
Power
"Pwr"
ANSI: T1.102, T1.107,
T1.404, T1-404a (T3),
Amber No Power On: Power available
No valid
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper
or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifica-
tions or tampering with equipment (including removal of equipment cover
by personnel not specifically authorized and certified by Omnitron), or mis-
use, or operating outside the environmental specification of the product
(including but not limited to voltage, ambient temperature, radiation, un-
usual dust, etc.), or improper site preparation or maintenance. No other
warranty is expressed or implied. Omnitron specifically disclaims the im-
plied warranties of merchantability and fitness for any particular purpose.
ITU: G.703, (E3), G.751, O.151
ETSI: EN 300 689, 300 686, 300 687
Fiber Activity
"Act"
Green
Fast blink (10Hz): Data Received
data
Fiber AIS
"AIS"
Amber
--
Fast blink (10Hz): AIS Received.
RG-59 Coax, 75 ohm, BNC
DS3: 380m, E3: 440m
Copper Connectors
Fiber Connectors
Local unit asserting Remote Loopback:
Fast blink (10Hz): Test pattern received.
Slow blink (1 Hz): Unexpected pattern
received.
Fiber Test
detected
"TST"
No Test
Amber Data
SC, ST, LC, MT-RJ, SFP
4. Connect the fiber cables between the T3/E3 converters. The Transmit
(TX) must attach to the Receive (RX) and the Receive must attach
to the Transmit.
5. When using a single-fiber models, you must use mating converters.
For example, if one converter is the model 8750-1 (TX=1310nm,
RX= 1550nm), the other converter must be model 8751-1 (TX=1550nm,
RX=1310nm).
6. Attach the BNC cables to the T3/E3 converter and attach the other
end of the cables to appropriate network equipment. The Transmit must
attach to the Receive and the Receive must attach to the Transmit.
T3/E3 Sel, Coax Build-Out, Coax En/Dis,
Fiber En/Dis, AIS to Fiber, AIS to Coax,
PRBS to Coax, Loop-Bk Coax,
Received Special Case:
Three quick blinks (2Hz) and pause (1sec.):
Illegal dip-switch selection.
Controls
Fig. 6 Board Mounted DIP-Switches
Exclusive Remedies
Loop-Bk Fiber, Loop-Bk Remote
ON: Local Fiber Loopback.
“T3” “E3” and “STS-1” DIP-Switches - Select Protocol:
The remedies provided herein are the Buyer’s sole and exclusive
remedies. Omnitron shall not be liable for any direct, indirect, special,
incidental, or consequential damages, whether based on contract, tort, or
any legal theory.
If "CLB" also "ON" indicates that the unit is
the Local Unit in Remote Loopback Mode.
Slow blink (1Hz) and also "CLB" in slow
blink: indicates that the unit is the Remote
Unit in Remote Loopback Mode.
Fiber
Loopback
"FLB"
Power, Fiber Act, Coax Act, Fiber AIS Det,
Coax AIS Det, Coax PRBS Det,
When the “T3” DIP-switch is in the right position, the T3 protocol is
selected. When the “E3” DIP-switch is in the right position, the E3 protocol
is selected. When the “STS-1” DIP-switch is in the right position, the STS-1
protocol is selected. Only one of the three DIP-switches may be in the
right position at any one time. The default setting of the module has no
mode selected (the module will default to E3 mode with no switches set).
Amber Normal
Amber Normal
LED Displays
Fiber Test, Fiber Loop-Bk, Coax Loop-Bk
Dimensions
Weight
W:0.85" x D:4.5" x H:2.8"
8 oz.
ON: Local Coax Loopback.
If "FLB" also "ON" indicates that the unit is
the Local Unit in Remote Loopback Mode.
Slow blink (1Hz) and also "FLB" in slow
blink: indicates that the unit is the Remote
Unit in Remote Loopback Mode.
Coax
Loopback
"CLB"
“<225/>225” Coax Build-Out Distance selection:
Warning
Compliance
Power Requirement
UL, CE, FCC Class A
0.7A @ 3.3VDC (typical)
When this DIP-switch is in the left position, a distance of less than 225 ft.
is selected. When in the right position, a distance of 225 ft. or higher is
selected. Select the appropriate distance for your application.
TECHNICAL SUPPORT:
The operating description in this Instruction Manual is for use by qualified
personnel only. To avoid electrical shock, do not perform any servicing of
this unit other than that contained in the operating instructions, unless you
are qualified and certified to do so by Omnitron Systems Technology, Inc.
For help with this product, contact our Technical Support:
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Phone:
Fax:
(949) 250-6510
(949) 250-6514
Coax Activity
"ACT"
No valid
Green
Fast blink (10Hz): Data Received
“CEN/CDIS” and “FEN/FDIS” Port Control DIP-Switches:
Temperature
data
When both DIP-switches are in the left position, the ports are enabled.
When the “CEN/CDIS” is in the right position, the coax port is disabled.
When the “FEN/FDIS” is in the right position, the fiber port is disabled.
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Coax AIS
detected
"AIS"
Warranty
Amber
Amber
--
--
Fast blink (10Hz): AIS Received.
Humidity
Altitude
5 to 95% (non-condensing)
-100m to 4000m
510,000
This product is warranted to the original purchaser against defects in
material and workmanship for a period of TWO YEARS from the date of
shipment. A LIFETIME warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days from the date of
shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED
REGISTRATION FORM. Or you may register your product on the Internet
at its option, repair or replace a product which is proven to be defective.
Irvine, CA 92618 USA
“PRBS” Pseudo Random Pattern Generator Control DIP-Switch:
When in the right position, the converter forces Pseudo Random pattern
out of the Coax-Out port. The data received at Fiber-In is discarded and
the data at Coax-In is passed through to Fiber-Out.
Coax PRBS
detected
"PRBS"
E-mail:
URL:
Blink 10 Hz: PRBS Received.
Blink 1 Hz: Forcing PRBS onto BNC-Out.
MTBF (hrs)
Note: Some combinations of DIP-switch settings are illegal, and
will be indicated by the Fiber Test “TST” LED blinking quickly three
times followed by a pause.