Omega Vehicle Security Thermometer HH2100 Series User Manual |
THX-HH2146T
THX-HH2106T
TEST RESULTS
Type T to BS 4937/DIN 43710
Thermistor
GB
®
®
®
®
®
®
®
®
®
®
®
®
®
®
[
[
]
]
THERMISTOR PROBE
CONNECTION POINTS
(NO POLARITY)
HH-2100
SERIES
Some of the options described may not apply to this
instrument. Please check the functions of the
instrument you have purchased before proceeding.
Model: ........................ Serial No: ..........................................
This instrument has been calibrated in: ..................................
Tested by: ...............................................................................
THERMOMETER
TYPE ‘T’ THERMOCOUPLE
CONNECTION POINTS
Model
Sensor
C/F
HH2106T HH2146T
T
X
Y
Thermistor
BROWN +VE
THERMISTOR
WHITE -VE
THERMISTOR
X
Y
Hold
FANWAL PART No. 194-22-LNS-CO1
R.T. CURVE 2252 0Hms @ 25°C
This instrument has been designed to meet environmental
condition:
X
Y
Instrument supplied pre-set to either °C or °F
Function available
Refer to rear of instrument for the temperature ranges.
Norm IP67 [
]
WARNING - Do not bring probe into contact with any service
connected to a hazardous voltage (i.e. a voltage exceeding
30 volts RMS or 42.4 volts peak with respect to either earth
or ground). Ensure that the probe is suitable for the
application, paying particular attention to the temperature
range and type of thermocouple. Connect probe plug into
the socket at top of instrument.
INPUT
READING
INSTRUMENT OPERATION
BATTERIES
Two AA or equivalent cells. Follow instructions on reverse of
instrument for fitting/replacement.
NOTE: Only probe listed should be used with the HH2100
series thermometer range.
When
symbol appears on display, replace batteries.
IP67 RATING
BACKLIGHT
Press and hold ON key.
The waterproof rating for this product will not be maintained
unless the screws holding the battery compartment are firmly
tightened when inserting or replacing batteries.
®
An OMEGA Technologies Company
DISPLAY
Servicing USA and Canada: Call OMEGA Toll Free
MULTIFUNCTION
MULTIFUNCTION
MULTIFUNCTION
ON - OFF
Press ON key for on and OFF key for off. Automatic switch-
off after 12 minutes. If
on, automatic switch-off function will be disabled until the unit
is switched off.
USA
Canada
976 Bergar
Laval (Quebec) H7L 5A1
Telephone: (514) 856-6928
FAX: (514) 856-6886
TIME LOG
NUMERIC
N
S
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Telephone: (203) 359-1660
FAX: (203) 359-7700
FAST
HH:MM
ENTRY RANGE
key is held when unit is switched
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
NE A/R
OK? A-B
NS
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM
Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
°C°FCal
PROBE CONNECTION
The following probes should be used with the HH2100 Series
Thermometers.
Servicing Europe: United Kingdom Sales and Distribution Centre
25 Swannington Road, Broughton Astley,
Leicestershire LE9 6TU, England
BATTERY
YES
ENTER
CAL
CELSIUS
Telephone: 44 (1455) 285520 FAX: 44 (1455) 283912
CHANNEL
Probe Code
THX-HH2146T
Thermistor
THX-HH2106T
T
FAHRENHEIT
OPERATING
SELECTION
The OMEGA Complete Measurement and
Control Handbooks & Encyclopedias
Sensor Type
Tip Dimensions
Handle Length
DISPLAY HOLD
Pressing
the display. Press
4
4
4
4
4
INSTRUCTIONS
120mm x 3.3mm
143mm
90mm x 3.3mm
143mm
Temperature
Data Acquisition Systems
Electric Heaters
key freezes the display and will appear on
key again to return to normal display.
4
4
Pressure, Strain & Force
Flow and Level
Environmental Monitoring
and Control
Units used with
HH2146T
HH2106T
pH and Conductivity
Call for your FREE Handbook Request Form today: (203) 359-RUSH
®
M-4017
13373
rev.1
An OMEGA Technologies Company
SENSOR OPEN CIRCUIT OR
OVERRANGE/UNDERRANGE INDICATION
If the sensor is open circuit, the display will show O-C as
long as condition exists.
INSTRUMENT ACCURACIES
All 1 digit.
Model HH2106T
0.2°C/0.4°F over range -20°C to +70°C/-4°F to +158°F
0.1% rdg 0.2°C/0.4°F elsewhere
Model HH2146T
0.2% rdg 0.1°C/0.2°F over range -150°C to +800°C/
-238°F to +1472°F
COMMON SPECIFICATION
Dimensions: 155 x 67 x 40mm/6.1 x 2.6 x 1.6 inches
Weight: 180g/6.4 oz
INSTRUMENT CALIBRATION
Please note that the HH2100 series range of thermometers
can only be calibrated by an Omega Service Center. For
details of your nearest center please refer to the end of these
operating instructions.
The overall performance of the instrument is obtained by combining the stated accuracy
andanyuncertaintyduetothemeasurementprocess.
Download from Www.Somanuals.com. All Manuals Search And Download.
|