Omega Vehicle Security Electric Heater OM5 C User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
GENERAL DESCRIPTION.............................................................................................................. 2  
OM5 SELECTION GUIDE ............................................................................................................... 2  
ANALOG VOLTAGE INPUT MODULES, NARROW BANDWIDTH: OM5-IMV/IV ....................... 4  
ANALOG CURRENT INPUT MODULES: OM5-II .......................................................................... 6  
TRUE RMS INPUT MODULES: OM5-IAC ..................................................................................... 8  
LINEARIZED 2- OR 3-WIRE RTD INPUT MODULES: OM5-IP/IC/IN ..............................................10  
LINEARIZED 4-WIRE RTD INPUT MODULES: OM5-IP4/IC4/IN4.............................................. 12  
POTENTIOMETER INPUT MODULES: OM5-PT......................................................................... 14  
THERMOCOUPLE INPUT MODULES: OM5-ITC ........................................................................ 16  
STRAIN GAGE INPUT MODULES, WIDE BANDWIDTH: OM5-WBS ....................................... 16  
ANALOG CURRENT OUTPUT MODULES: OM5-IVI ................................................................. 20  
ANALOG VOLTAGE INPUT MODULES, WIDE BANDWIDTH: OM5-WMV/WV ....................... 22  
2-WIRE TRANSMITTER INTERFACE MODULES: OM5-TX ............................................................ 24  
GENERAL PURPOSE INPUT MODULES, DC EXCITATION: OM5-DT .................................... 26  
FREQUENCY INPUT MODULES: OM5-IFI ................................................................................ 28  
LINEARIZED THERMOCOUPLE INPUT MODULES: OM5-LTC...................................................... 30  
VOLTAGE OUTPUT MODULES, 50mA DRIVE CAPACITY: OM5-AV ...................................... 32  
DIMENSIONS AND ACCESSORIES ............................................................................................ 34  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-WMV/WV  
Analog Voltage Input Modules, Wide Bandwidth  
DESCRIPTION  
FEATURES  
Each OM5 wide bandwidth voltage input module provides a single channel  
of analog input which is amplified, isolated, and converted to a high level  
analog voltage output (Figure 1). This voltage output is logic-switch  
controlled, allowing these modules to share a common analog bus without  
the requirement of external multiplexers.  
ACCEPTS MILLIVOLT AND VOLTAGE LEVEL SIGNALS  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
The OM5 modules are designed with a completely isolated computer side  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
INPUT PROTECTED TO 240VAC CONTINUOUS  
100dB CMR  
10kHz SIGNAL BANDWIDTH  
0.05% ACCURACY  
0.02% LINEARITY  
1µV/°C DRIFT  
The input signal is processed through a pre-amplifier on the field side of  
the isolation barrier. This pre-amplifier has a gain-bandwidth product of  
5MHz and is bandwidth limited to 10kHz. After amplification, the input  
signal is chopped by a proprietary chopper circuit. Isolation is provided by  
transformer coupling, again using a proprietary technique to suppress  
transmission of common mode spikes or surges. The module is powered  
from +5VDC, 5%.  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
A special input circuit provides protection against accidental connection of  
power-line voltages up to 240VAC.  
4
NC  
Anti-Aliasing  
Filter  
Isochopper™  
20  
+EXC  
+In  
LPF  
Amplifier  
VOUT  
4
3
2
1
Surge  
Suppression  
and  
Pat Pending  
6
VIN  
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
+V  
–V  
–In  
–EXC  
NC  
Isolated  
Computer-Side  
Power  
Backpanel  
Term Block  
1
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-WMV/WV Block Diagram.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V Power.  
Module  
OM5-WMV  
OM5-WV  
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
10mV to 100mV  
0.5nA  
1V to 40V  
0.05nA  
200MΩ  
40kΩ  
40kΩ  
650k(minimum)  
650k(minimum)  
650k(minimum)  
240Vrms Max  
ANSI/IEEE C37.90.1-1989  
*
*
CMV, Input to Output  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR (–3dB at 10kHz)  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
100dB  
*
*
*
*
120dB per Decade above 10kHz  
Accuracy(1)  
0.05% Span 10µV RTI(2) 0.05%(VZ(3)  
)
0.05% span 0.2mV RTI(2)  
0.05% (VZ(3)  
*
)
Nonlinearity  
0.02% Span  
Stability  
Input Offset  
Output Offset  
Gain  
1µV/°C  
40µV/°C  
25ppm/°C  
20µV/°C  
*
50ppm/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Rise Time, 10 to 90% Span  
Settling Time, to 0.1%  
0.4µVrms  
10mVp-p  
10kHz  
35µs  
250µs  
2µVrms  
*
*
*
*
Output Range  
5V or 0V to +5V  
50Ω  
*
*
*
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
Output Current Limit  
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
)
*
*
8mA  
Output Enable Control  
Max Logic “0”  
+0.8V  
+2.4V  
+36V  
*
*
*
*
Min Logic “1”  
Max Logic “1”  
Input Current, “0”, “1”  
0.5µA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
*
*
2µV/% RTI(2)  
200µV/% RTI(2)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
*
* Same specification as OM5-  
WMV.  
NOTES: (1) Includes nonlinearity,  
hysteresis and repeatability.  
(2) RTI = Referenced to input.  
(3) V is the input voltage  
that rZesults in 0V output.  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
*
*
*
*
0 to 95% Noncondensing  
EN50081-1, ISM Group 1,  
Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
*
ORDERING  
INFORMATION  
MODEL  
OM5-WMV-10A-C  
OM5-WMV-50A-C  
OM5-WMV-100A-C –100mV to +100mV  
OM5-WMV-10B-C  
OM5-WMV-50B-C  
INPUTRANGE  
–10mV to +10mV  
–50mV to +50mV  
OUTPUTRANGE  
–5V to +5V  
–5V to +5V  
–5V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
–5V to +5V  
–5V to +5V  
–5V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
–5V to +5V  
0V to +5V  
–5V to +5V  
0V to +5V  
–10mV to +10mV  
–50mV to +50mV  
OM5-WMV-100B-C –100mV to +100mV  
OM5-WV-1A-C  
OM5-WV-5A-C  
OM5-WV-10A-C  
OM5-WV-1B-C  
OM5-WV-5B-C  
OM5-WV-10B-C  
OM5-WV-20A-C  
OM5-WV-20B-C  
OM5-WV-40A-C  
OM5-WV-40B-C  
–1V to +1V  
–5V to +5V  
–10V to +10V  
–1V to +1V  
–5V to +5V  
–10V to +10V  
–20V to +20V  
–20V to +20V  
–40V to +40V  
–40V to +40V  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-TX  
2-Wire Transmitter Interface Modules  
FEATURES  
ISOLATED +20VDC CURRENT LOOP SUPPLY  
ter. This allows a 2-wire loop powered transmitter to be directly connected  
to the module without requiring an external power supply. The regulated  
supply will provide a nominal +20VDC at a loop current of 4mA to 20mA.  
PROVIDES ISOLATION FOR NON-ISOLATED 2-WIRE  
The OM5-TX will provide a 1500V isolation barrier for non-isolated 2-wire  
field transmitters. It can also be used when additional isolation is required  
between an isolated 2-wire transmitter and the input stage of the control  
room computer.  
TRANSMITTERS  
HIGH LEVEL VOLTAGE OUTPUT: +1V to +5V or +2V to +10V  
1500Vrms TRANSFORMER ISOLATION  
The voltage output is logic switch controlled, which allows these modules  
to share a common analog bus without the requirement of external  
multiplexers.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
100dB CMR  
The modules are designed with a completely isolated computer side circuit  
which can be floated to 50V from Power Common, pin 16. This complete  
isolation means that no connection is required between I/O Common and  
Power Common for proper operation of the output switch. If desired, the  
output switch can be turned on continuously by simply connecting pin 22,  
the Read-Enable pin to I/O Common, pin 19.  
100Hz SIGNAL BANDWIDTH  
0.05% ACCURACY  
0.02% LINEARITY  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
A precision 20current conversion resistor is supplied with the module.  
Sockets are provided on the OM5-BP backpanels to allow installation of  
this resistor. Extra resistors are available under part number OMX-1362-C.  
All field inputs are fully protected from accidental connection of power-line  
voltages up to 240VAC. The module has a 3dB bandwidth of 100Hz. Signal  
filtering is accomplished with a six-pole filter, with two poles on the field  
side of the isolation barrier, and the other four on the computer side.  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
DESCRIPTION  
Each OM5-TX 2-wire transmitter interface module provides a single chan-  
nel which accepts a 4 to 20 mA process current input and provides a  
standard +1 to +5V or +2 to +10V output signal (Figure 1). An isolated  
+20VDC regulated power supply is provided to power the current transmit-  
2-Wire  
Transmitter  
+EXC  
+In  
4
6
LPF  
Isochopper™  
20  
4
3
2
1
LPF  
Amplifier  
VOUT  
Surge  
Suppression  
and  
Pat Pending  
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
–In  
+V  
–V  
Isolated  
Excitation  
Source  
–EXC  
Isolated  
20  
Computer-Side  
Power  
0.1% plug-in  
OMX-1362-C  
Backpanel  
Term Block  
1
NC  
NC  
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power  
Common  
FIGURE 1. OM5-TX Block Diagram.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Module  
OM5-TX  
Input Range  
Input Resistor  
Value  
4mA to 20mA  
20.00Ω  
0.1%  
Accuracy  
Stability  
Loop Supply Voltage  
10ppm/°C  
Nominal 20V at 4mA to 20mA  
Isolated Excitation Protection  
Continuous  
Transient  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
Input Protection  
Continuous  
Transient  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
CMV, Input to Output  
Continuous  
Transient  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
CMR (50 or 60Hz)  
NMR (–3dB at 100Hz)  
100dB  
120dB per decade above 100Hz  
Accuracy(1)  
Nonlinearity  
Stability  
0.05% span 4µA RTI(2)  
0.02% span  
Input Offset  
Output Offset  
Gain  
1µV/°C  
40µV/°C  
25ppm/°C of reading  
Noise  
Input, 0.1 to 10Hz  
Output, 100KHz  
Bandwidth, –3dB  
Response Time, 90% span  
10nArms  
500µVrms  
100Hz  
4mS  
Output Range  
+1V to +5V or +2V to +10V  
50Ω  
Continuous short to gnd  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
+0.8V  
+2.4V  
+36V  
Max Logic “1”  
Input Current, “0, 1”  
0.5µA  
Power Supply Voltage  
Power Supply Current  
+5VDC 5%  
180mA at transmitter load of 20mA  
100mA at transmitter load of 4mA  
10µV/% RTI(2)  
Power Supply Sensitivity  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.  
(2) RTI = Referenced to input.  
ORDERINGINFORMATION  
MODEL  
INPUTRANGE  
OUTPUTRANGE  
OM5-TX-1-C  
OM5-TX-2-C  
4mA to 20mA  
4mA to 20mA  
+1V to +5V  
+2V to +10V  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-DT  
General Purpose Input Modules, with DC Excitation  
FEATURES  
controlled, which allows these modules to share a common analog bus  
without the requirement of external multiplexers.  
INTERFACES TO DC DISPLACEMENT TRANSDUCERS AND OTHER  
DEVICES REQUIRING A STABLE DC SUPPLY  
The modules are designed with a completely isolated computer side circuit  
which can be floated to 50V from Power Common, pin 16. This complete  
isolation means that no connection is required between I/O Common and  
Power Common for proper operation of the output switch. If desired, the  
output switch can be turned on continuously by simply connecting pin 22,  
the Read-Enable pin to I/O Common, pin 19.  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
FULLY ISOLATED EXCITATION SUPPLY  
100dB CMR  
The OM5-DT can interface to devices which require a precision 10VDC  
excitation supply. The 1kHz bandwidth significantly reduces ripple and  
noise inherent in these devices.  
Transducer excitation is provided from the module by a very stable 10V  
source. The excitation supply is fully isolated, allowing the amplifier inputs  
to operate over the full range of the excitation voltage. This feature offers  
significant flexibility in real world applications. Eight full scale input ranges  
are provided, from 1V to 10V, producing 5V full scale output.  
1KHz SIGNAL BANDWIDTH  
0.10% ACCURACY  
0.02% LINEARITY  
20µV/°C DRIFT  
The input signal is processed through a pre-amplifier on the field side of  
the isolation barrier. This pre-amplifier has a gain-bandwidth product of  
5MHz and is bandwidth limited to 1kHz. After amplification, the input signal  
is chopped by a proprietary chopper circuit. Isolation is provided by  
transformer coupling, again using a proprietary technique to suppress  
transmission of common mode spikes or surges. The module is powered  
from +5VDC, 5%.  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
DESCRIPTION  
Each OM5-DT general purpose input module provides a single channel of  
transducer input which is filtered, isolated, scaled, and converted to a high  
level analog voltage output (Figure 1). This voltage output is logic switch  
Special input circuits provide protection of the signal inputs and the  
isolated excitation supply up to 240VAC.  
+EXC  
+In  
4
LPF  
Isochopper™  
20  
4
3
2
1
LPF  
Amplifier  
VOUT  
Surge  
Suppression  
and  
6
5
3
Pat Pending  
DC LVDT  
or Other  
Transducer  
19  
22  
Protection  
I/O Common  
RD EN\  
+V  
–V  
–In  
Isolated  
Excitation  
Source  
Isolated  
Computer-Side  
Power  
–EXC  
Backpanel  
Term Block  
1
NC  
2
NC  
+V  
17  
16  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
–V  
Power  
Common  
FIGURE 1. OM5-DT Block Diagram.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Module  
OM5-DT  
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
1V to 10V  
0.05nA  
2M(minimum)  
2M(minimum)  
2M(minimum)  
240Vrms max  
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)  
Excitation Voltage, VEXC  
Excitation current  
Excitation Load Regulation  
Excitation Stability  
Isolated Excitation Protection  
Continuous  
+10.0VDC 2mV  
40mA (maximum)  
5ppm/mA  
15ppm/°C  
240Vrms max  
Transient  
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)  
CMV, Input to Output  
Continuous  
Transient  
CMR (50 or 60Hz)  
NMR (–3dB at 1kHz)  
1500Vrms max  
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)  
100dB  
120dB per decade above 1kHz  
Accuracy(1)  
Nonlinearity  
0.1% span, 0.2mV RTI2  
0.02% span  
Stability  
Input Offset  
Output Offset  
Gain  
20µV/°C  
40µV/°C  
50ppm/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100KHz  
0.4µVrms  
5mVpp  
Bandwidth, –3dB  
Response Time (to 90% final value)  
1kHz  
750µs  
Output Range  
5V  
50Ω  
Output Resistance  
Output Protection  
Output Selection Time  
Continuous short to ground  
6.0µs at Cload = 0 to 2000pF  
(to 1mV of VOUT  
)
Output Current Limit  
8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
+0.8V  
+2.4V  
+36V  
Max Logic “1”  
Input Current, “0, 1”  
0.5µA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
200mA @ Full Exc. load, 100mA @ No Exc. Load  
200µV/% RTI(2)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% noncondensing  
ORDERINGINFORMATION  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
MODEL  
MAXIMUM INPUT  
OUTPUT  
Immunity  
OM5-DT-1-C  
OM5-DT-2-C  
OM5-DT-3-C  
OM5-DT-4-C  
OM5-DT-5-C  
OM5-DT-6-C  
OM5-DT-7-C  
OM5-DT-8-C  
OM5-DT-9-C  
OM5-DT-10-C  
1V  
2V  
3V  
4V  
5V  
6V  
7V  
8V  
9V  
10V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
NOTES:  
(1) Includes excitation error, nonlinearity, hysteresis and repeatability.  
(2) RTI = Referenced to input.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IFI  
Frequency Input Modules  
FEATURES  
DESCRIPTION  
ACCEPTS FREQUENCY INPUTS OF 0 to 100kHz  
PROVIDES HIGH LEVEL VOLTAGE OUTPUTS  
TTL LEVEL INPUTS  
Each OM5-IFI Frequency input module provides a single channel of fre-  
quency input which is isolated and converted to a high level analog voltage  
output. This voltage output is logic switch controlled, which allows these  
modules to share a common analog bus without the requirement of external  
multiplexers (Figure 1).  
1500 VOLT TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
0.05% ACCURACY  
The frequency input signal can be a TTL level signal or a zero-crossing signal.  
Terminal 3 (+In) on the field-side terminal block is the “common” or ground  
connection for input signals. A TTL signal is connected from terminal 2 (–In)  
to terminal 3 (+In), while a zero-crossing signal is connected from terminal 4  
(+EXC) to terminal 3 (+In). Input circuitry for each of the signal types has  
hysteresis built in. An input signal must cross entirely through the hysteresis  
region in order to trigger the threshold comparator.  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
A 5.1V excitation is available for use with magnetic pick-up or contact-  
closure type sensors. The excitation is available on pin 1 (–EXC) and the  
excitation common is pin 3 (+In).  
The modules are designed with a completely isolated computer side circuit  
which can be floated to 50V from Power Common, pin 16. This complete  
isolation means that no connection is required between I/O Common and  
Power Common for proper operation of the output switch. If desired, the  
output switch can be turned on continuously by simply connecting pin 22,  
the Read-Enable pin to I/O Common, pin 19.  
A special circuit in the input stage of the module provides protection against  
accidental connection of power-line voltages up to 240VAC.  
Threshold  
Comparator  
F to V  
Zero-Crossing  
4
6
Inputs  
+
+EXC  
+In  
Signal  
Isolation  
20  
4
3
2
1
LPF  
VOUT  
Surge  
Suppression  
and  
+
TTL  
Inputs  
–In  
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
+V  
–V  
–EXC  
Isolated  
Computer-Side  
Power  
5.1V  
Backpanel  
Term Block  
1
NC  
NC  
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-IFI Block Diagram.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at Ta = +25C and +5V Power  
Module  
OM5-IFI  
Input Range  
Input Threshold  
Minimum Input  
Maximum Input  
Minimum Pulse Width  
TTL Input Low  
TTL Input High  
Input Hysteresis  
Zero Crossing  
TTL  
0 to 100KHz  
Zero Crossing  
60mVp-p  
350Vp-p  
4µs  
0.8V max  
2.4V min  
0.04V  
1.5V  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
100KΩ  
100KΩ  
100KΩ  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
+5.1V @ 8mA max  
Transient  
Excitation  
CMV, Input to Output  
Continuous  
Transient  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
120dB  
CMR (50 or 60Hz)  
Accuracy(1)  
Nonlinearity  
0.05% span  
0.02% span  
Stability  
Offset  
Gain  
Noise  
40ppm/°C  
40ppm/°C  
Output Ripple  
Response Time (0 to 90%)  
OM5-IFI-500/1K-C  
OM5-IFI-3K-C  
OM5-IFI-5K/10K-C  
OM5-IFI-25K/50K/100K-C  
<10mVp-p @ Input >2% span  
300 ms  
170 ms  
90 ms  
20 ms  
Output Range  
0V to +5V  
50Ω  
Continuous short to ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
+0.8V  
+2.4V  
+36V  
Max Logic “1”  
Input Current, “0,1”  
0.5µA  
ORDERINGINFORMATION  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
110mA  
150µV/% RTO  
MODEL  
INPUTRANGE  
OUTPUTRANGE  
(2)  
OM5-IFI-500-C  
OM5-IFI-1K-C  
OM5-IFI-3K-C  
OM5-IFI-5K-C  
OM5-IFI-10K-C  
OM5-IFI-25K-C  
OM5-IFI-50K-C  
OM5-IFI-100K-C  
0 to 500Hz  
0 to 1kHz  
0 to 3kHz  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
-40°C to +85°C  
-40°C to +85°C  
0 to 95% noncondensing  
0 to 5kHz  
0 to 10kHz  
0 to 25kHz  
0 to 50kHz  
0 to 100kHz  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.  
(2) RTO = Referenced to Output.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-LTC  
Linearized Thermocouple Input Modules  
FEATURES  
INTERFACES TO TYPES J, K, T, E, R, S, N, AND B  
The OM5-LTC modules are designed with a completely isolated computer  
side circuit which can be floated to 50V from Power Common, pin 16.  
This complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
THERMOCOUPLES  
LINEARIZES THERMOCOUPLE SIGNAL  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
The OM5-LTC can interface to eight industry standard thermocouple types:  
J, K, T, E, R, S, N, and B. Its corresponding output signal operates over a  
0V to +5V range. Each module is cold-junction compensated to correct for  
parasitic thermocouples formed by the thermocouple wire and screw  
terminals on the mounting backpanel. Upscale open thermocouple detect  
is provided by an internal pull-up resistor. Downscale indication can be  
implemented by installing an external 47Mresistor, 20% tolerance,  
between screw terminals 1 and 3 on the OM5-BP backpanels.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
95dB NMR AT 60Hz, 90dB at 50Hz  
1µV/°C DRIFT  
Signal filtering is accomplished with a six-pole filter which provides 95dB  
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter  
are on the field side of the isolation barrier, and the other four are on the  
computer side.  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
After the initial field-side filtering, the input signal is chopped by a  
proprietary chopper circuit. Isolation is provided by transformer coupling,  
again using a proprietary technique to suppress transmission of common  
mode spikes or surges. The module is powered from +5VDC, 5%.  
DESCRIPTION  
Each OM5-LTC thermocouple input module provides a single channel of A special input circuit provides protection against accidental connection of  
thermocouple input which is filtered, isolated, amplified, linearized and power-line voltages up to 240VAC.  
converted to a high level analog voltage output (Figure 1). This voltage  
output is logic-switch controlled, allowing these modules to share a  
common analog bus without the requirement of external multiplexers.  
+2.5V  
100M  
20  
VOUT  
Linearizer  
LPF  
4
NC  
+EXC  
+In  
LPF  
Isochopper™  
Amplifier  
Pat Pending  
4
3
2
1
19  
22  
I/O Common  
RD EN\  
Surge  
Suppression  
and  
6
Thermocouple  
5
3
Protection  
+V  
–V  
–In  
–EXC  
Isolated  
Computer-Side  
Power  
Precision  
Reference  
Backpanel  
Term Block  
CJC  
1
2
17  
+V  
–V  
+5V  
Temp  
Sensor  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
16  
Power Common  
FIGURE 1. OM5-LTC Block Diagram.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Module  
OM5-LTC  
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
–0.1V to +0.5V  
–25nA  
50M  
40kΩ  
40kΩ  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
CMV, Input to Output  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
95dB at 60Hz, 90dB at 50Hz  
Accuracy  
See Ordering Information  
Stability  
Input Offset  
Output Offset  
Gain  
1µV/°C(1)  
20µV/°C  
25ppm/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% Span  
0.2µVrms  
300µVp-p, 150µVrms  
4Hz  
0.2s  
Output Range  
0V to +5V  
50Ω  
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
+0.8V  
+2.4V  
+36V  
Min Logic “1”  
Max Logic “1”  
Input Current, “0”, “1”  
Open Input Response  
Open Input Detection Time  
Cold Junction Compensation  
Accuracy, 25°C  
0.5µA  
Upscale  
10s  
0.25°C  
0.5°C  
1.25°C  
Accuracy, +5°C to +45°C  
Accuracy, –40°C to +85°C  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
2µV/% RTI(2)  
Mechanical Dimensions  
2.28" x 2.26" x 0.6"  
(58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
NOTES: (1) This is equivalent to °C as follows:  
Type J 0.020 °C/°C, Types K, T 0.025°C/°C,  
Type E 0.016°C/°C, Types R, S 0.168°C/°C,  
Type N 0.037°C/°C, Type C 0.072°C/°C.  
(2) Referenced to input.  
0 to 95% Noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
MODEL  
TYPE  
INPUT RANGE  
OUTPUT RANGE  
ACCURACY†  
ORDERING  
OM5-LTC-J1-C  
OM5-LTC-J2-C  
OM5-LTC-J3-C  
OM5-LTC-J4-C  
OM5-LTC-K1-C  
OM5-LTC-K2-C  
OM5-LTC-K3-C  
OM5-LTC-T1-C  
OM5-LTC-T2-C  
OM5-LTC-E-C  
OM5-LTC-R-C  
OM5-LTC-S-C  
OM5-LTC-B-C  
Type J  
Type J  
Type J  
Type J  
Type K  
Type K  
Type K  
Type T  
Type T  
Type E  
Type R  
Type S  
Type B  
0°C to +760°C (+32°F to +1400°F)  
-100°C to +300°C (-148°F to +572°F)  
0°C to +500°C (+32°F to 932°F)  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0.08%  
0.08%  
0.07%  
0.08%  
0.08%  
0.08%  
0.08%  
0.16%  
0.13%  
0.10%  
0.10%  
0.10%  
0.15%  
0.61°C  
0.32°C  
0.36°C  
0.70°C  
0.80°C  
0.38°C  
1.2°C  
INFORMATION  
-100°C to +760°C (-148°F to +1400°F)  
0°C to +1000°C (+32°F to +1832°F)  
0°C to +500°C (+32°F to +932°F)  
-100°C to +1350°C (-148°F to +2462°F)  
-100°C to +400°C (-148°F to +752°F)  
0°C to +200°C (+32°F to +392°F)  
0°C to +1000°C (+32°F to +1832°F)  
+500°C to +1750°C (+932°F to +3182°F)  
+500°C to +1750°C (+932°F to +3182°F)  
+500°C to +1800°C (+932°F to +3272°F)  
0.80°C  
0.25°C  
1.0°C  
1.3°C  
Includes conformity,  
hysteresis and  
1.3°C  
2.0°C  
repeatability. Does not  
include CJC accuracy.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-AV  
Voltage Output Modules  
FEATURES  
DESCRIPTION  
ACCEPTS HIGH LEVEL VOLTAGE INPUTS TO 10V  
PROVIDES HIGH LEVEL VOLTAGE OUTPUTS TO 10V  
1500 VOLT TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1e-1989 TRANSIENT PROTECTION  
5 POLES OF FILTERING  
Each OM5-AV voltage output module provides a single channel of analog  
output. Thetrack-and-holdcircuitintheinputstagecanbeoperatedinahold  
mode where one DAC can supply many output modules, or a track mode  
whereoneDACisdedicatedtoeachmodule. Inadditiontothetrack-and-hold  
circuit, each module provides signal buffering, isolation, filtering, and  
conversion to a high level voltage output.  
Setting of the track or hold mode is controlled by the logic state of WR EN\,  
module pin 23. When pin 23 is low, the track mode is enabled. If pin 23 is  
open or high, the hold mode is enabled. The module is designed with a  
completely isolated computer side circuit which can be floated to 50V from  
Power Common, pin 16. This complete isolation means that no connection  
is required between I/O Common and Power Common for proper operation  
of the track and hold circuit. For a low state, simply connect pin 23, the Write-  
Enable pin, to I/O Common, pin 19.  
110dB CMR  
400Hz SIGNAL BANDWIDTH  
0.05% ACCURACY  
0.02% LINEARITY  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
The OM5-BP-MUX-C backpanels allow host computer control of the WR EN\  
control line, which allows multiplexing of one host DAC to up to 64 OM5-AV  
output modules. During power up, the output remains 0V output for 100ms,  
which allows the track-and-hold circuit to be initialized.  
Isolation Barrier  
Track  
&
Hold  
18  
19  
23  
Range  
Select  
VIN  
+EXC  
4
NC  
4
+Out  
6
5
3
Surge  
Suppression  
and  
I/O Common  
WR EN\  
RLOAD  
3
2
1
Protection  
–Out  
+V  
–V  
NC  
–EXC  
Isolated  
Computer-Side  
Power  
Backpanel  
Term Block  
1
NC  
NC  
2
17  
16  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-AV Block Diagram.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA= +25C and +5V Power  
Module  
OM5-AV  
Input Voltage Range  
Input Voltage Maximum  
Input Resistance  
5V, 0 to +5V, 10V, 0 to +10V  
36V (no damage)  
50MΩ  
Output Voltage Range  
Over Range Capability  
Output Drive  
Output Resistance  
Output I Under Fault, Max  
Output Protection  
Transient  
5V, 0 to +5V, 10V, 0 to +10V  
5% @ 10V output  
50mA max  
0.5Ω  
75mA  
ANSI/IEEE C37.90.1-1989  
CMV, Output to Input  
Continuous  
Transient  
CMR (50 or 60Hz)  
NMR (–3dB at 400Hz)  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
110dB  
100dB per Decade above 400Hz  
Accuracy(1)  
Nonlinearity  
0.05% span (0-5mA load)  
0.02% span  
Stability  
Zero  
Span  
Noise  
25ppm/°C  
20ppm/°C  
Output Ripple, 1kHz bandwidth  
Bandwidth, -3dB  
2mVp-p  
400Hz  
Sample and Hold  
Output Droop Rate  
Acquisition Time  
0.2% Span/s  
50µs  
Track-and-Hold Enable Control  
Max Logic “0”  
Min Logic “1”  
+0.8V  
+2.4V  
+36V  
Max Logic “1”  
Input Current, “0”  
0.5µA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
350mA Full load, 135mA No load  
12.5ppm/%  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
RFI Susceptibility  
Emissions  
-40°C to +85°C  
-40°C to +85°C  
0 to 95% noncondensing  
0.5% Span error at 400MHz, 5W, 3ft  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.  
ORDERINGINFORMATION  
MODEL  
INPUTRANGE  
OUTPUTRANGE  
OM5-AV-1-C  
OM5-AV-2-C  
OM5-AV-3-C  
OM5-AV-4-C  
OM5-AV-5-C  
OM5-AV-6-C  
OM5-AV-7-C  
0V to +5V  
-5V to +5V  
-5V to +5V  
0V to +10V  
-10V to +10V  
-10V to +10V  
-5V to +5V  
-5V to +5V  
-5V to +5V  
0V to +5V  
-10V to +10V  
-10V to +10V  
0V to +10V  
-10V to +10V  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5  
Module Dimensions and Pinouts  
The following mechanical drawing is useful if designing circuit boards to  
mount the OM5 modules. Many sockets are available which accept the  
mounting pins. As an example, AMP Inc. provides a socket with part  
number 50865-5. The captive nut for the 3mm mounting screw can be  
obtained from PEM (Penn Engineering and Manufacturing), part number  
KFS2-M3.  
Top  
2.255" (57.3mm)  
[2.260" max (57.4mm)]  
0.585" (14.9mm)  
[0.590" max (15.0mm)]  
2.270" (57.7mm)  
[2.275" max (57.8mm)]  
Side  
0.20" (5.1mm)  
0.095" (2.4mm)  
0.375" (9.5mm)  
1.175" (29.8mm)  
1.650" (41.9mm)  
0.145" (3.7mm)  
0.345" (8.8mm)  
Pin Diameter = 0.040" (1.02mm)  
0.0750" (1.9mm)  
0.150" (3.8mm)  
Bottom  
0.345" (8.8mm)  
2.025" (51.4mm)  
1.650" (41.9mm)  
1.175" (29.8mm)  
0.900" (22.9mm)  
0.375" (9.5mm)  
0
NOTES: (1) All dimensions are “Typical” unless otherwise noted.  
(2) Mounting pin plating is 20µ in. gold.  
23  
17  
23  
22  
22  
WR EN\  
WR EN\  
RD EN\  
RD EN\  
Reserved  
VOUT  
Reserved  
VOUT  
VIN  
I/O Common  
+5V  
I/O Common  
VIN  
+5V  
Power Common Power Common  
17  
16  
6
16  
6
5
1
5
1
+In  
+In  
+EXC  
+SEN  
–In  
–EXC  
–SEN  
–In  
+EXC  
+SEN  
–EXC  
–SEN  
2
2
Top View  
Bottom View  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories  
for OM5 Analog Modules  
FEATURES  
SINGLE, DUAL, 8-, AND 16-POSITION BACKPANELS  
INTERFACE CABLES  
MODULE EVALUATION BOARD  
DIN RAIL MOUNT BACKPANELS  
CABLE-TO-SCREW-TERMINAL INTERFACE BOARD  
19-INCH MOUNTING RACK FOR BACKPANELS  
MULTIPLEXED AND NON-MULTIPLEXED BACKPANELS  
OM5-BP-16-C 16 POSITION ANALOG I/O BACKPANEL, NON-MULTIPLEXED  
DESCRIPTION  
Figure 2 for schematic). Field connections are terminated with four screw  
terminals at each module site. Use system interface cable OMX-1315-XX-  
C for connection to the host system.  
The OM5-BP-16-C 16 channel backpanel (Figure 1) can accept any of the  
OM5 analog modules in any mixture. It can be mounted on the OMX-1363-  
C 19-inch metal rack. The OM5-BP-16-C has 16 non-addressable analog I/  
O signal channels which provides each module with it’s own analog bus. The  
moduleoutputswitchiscontinuouslyonwhenusingthisbackpanelandall  
sixteen module outputs are simultaneously accessible to high-speed data  
acquisition (ADC) boards. A set of inter-channel bridge jumpers permits  
connecting an input module’s output to an output module’s input, providing  
two levels of isolation. A temperature sensor is mounted on each channel to  
provide cold junction compensation for thermocouple input modules (See  
SPECIFICATIONS  
Operating Temperature:  
–40°C to +85°C  
95% relative humidity, non-condensing  
Interface Connector:  
Field  
Logic  
High Density Screw Clamp, 14 AWG Max  
26-pin, male header connector  
Inter-channel  
Bridge Jumpers  
17.4" (442.0mm)  
17.1" (434.3mm)  
11.3" (287.0mm)  
7.6" (193.0mm)  
3.9" (99.1mm)  
0.15"  
(3.8mm)  
26 Conductor Male Pin  
Connectors P1, P2(1)  
P2P1  
1.275"  
(32.4mm)  
3.47"  
JP15  
E3  
E2  
E1  
(88.1mm)  
3.05"  
(77.5mm)  
JP1  
10.32 X 0.40  
Ground Lug, Including  
Nut and Lockwasher  
J4  
J1 J2 J3  
OMX-CJC-C  
Cold Junction  
Compensation Circuit  
Pin 2  
Pin 1  
Pin 1  
Pin 2  
+5VDC Supply  
Sockets for Current Conversion Resistors, OMX-1362-C  
0.08"  
16  
(2.0mm)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Channel  
Swaged Standoff  
Thru Hole 0.15" (3.8mm) Dia.  
2.27"  
(57.7mm)  
0.093"  
(2.4mm)  
0.75" (19.1mm)  
0.14" (3.6mm)  
inside diameter  
NOTES:  
1. Connector is Berg 65863-075 or equivalent.  
Mating Connector is Amp 49958-6 or equivalent.  
Connectors P1 and P2 are wired in parallel for “daisy chaining” up to 4 boards.  
FIGURE 1. OM5-BP-16-C Analog I/O Backpanel Dimensions.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 2. OM5-BP-16-C Schematic.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GROUNDING  
ELECTRICAL  
Figure 4 details the optional ground jumper configuration available on the  
OM5-BP-16-C backpanel. Jumpers J1, J3, and J4 are factory installed.  
P1 AND P2 CONNECTOR  
Connection to the host system is made at connectors P1 and P2. These  
connectors are electrically equivalent. Two connectors are provided to allow  
both analog input and analog output from host systems having individual  
input and output connectors.  
Jumper J1 connects the AGND shield wires (pins 3, 6, 9, 12, 15, 18, 21, and  
24) to the backpanel signal ground. This provides a ground connection  
between the host system and backpanel. Jumper J1 is required if output  
modules are used, or if there is no high impedance sense input (input low of  
a differential or pseudo-differential system) on the host measurement sys-  
tem.  
ADJACENT CHANNEL JUMPERS  
Adjacent channels may be connected together to provide an isolated output  
signal from an isolated input module, providing two levels of 1500V  
isolation. This capability is provided with the 15 jumpers labeled JP1  
through JP15 on headers E1, E2, and E3. A simplified drawing of the OM5-  
BP-16-C schematic for Channel 1 through 4 is shown in Figure 3.  
Jumper J3 connects the SENSE line (pin 25) to the backpanel signal ground.  
If the host system has the capability, this allows measuring the OM5-BP-16-  
C ground potential.  
For proper operation of the output switch or track-and-hold circuit when  
usingtheOM5backpanels, acurrentpathmustexistbetweenthehostcontrol  
logic power common and module I/O Common (module pin 19). This path  
can be established on the OM5-BP-16-C via jumper J4. If this connection  
exists elsewhere in the system, jumper J4 should be removed since possible  
ground loops could exist. Other connections of power ground and signal  
Example: Assume an OM5-IMV input module is installed in Channel 1  
position and an OM5-IVI output module is installed in Channel 2 position.  
IfJP1isinstalled,theoutputofChannel1isconnectedtotheinputofChannel  
2, which provides two levels of 1500V isolation.  
HD10, E1  
JP1  
JP2  
JP3  
JP4  
P2  
P1  
P2  
P1  
3
1
2
3
4
5
6
1
5
7
OM5 Module  
6
9
11  
13  
12  
15  
18  
21  
24  
25  
AGND  
I/O COM 19  
16 PWR COM  
20  
18  
20  
18  
20  
18  
20  
18  
VOUT  
VIN  
VOUT  
VIN  
VOUT  
VIN  
VOUT  
VIN  
J3  
J1  
J4  
Sense  
J2  
Power Common  
Signal Ground  
and  
Grounding Bolt  
CH 1  
CH 2  
CH 3  
CH 4  
R
1
FIGURE 3. OM5-BP-16-C Adjacent Channel Jumpers.  
POWER  
FIGURE 4. OM5-BP-16-C Grounding Diagram.  
The OM5-BP-16-C backpanel requires external +5VDC 5% power. The ground usually occur at the A/D or D/A converter of the host measurement  
chassis mounted OMX-976-C power supplies have adequate capacity to system.  
power any combination of modules.  
If the connection of power common and AGND shield wires exists in the host  
FUSING  
measurement system, an optional resistive connection between AGND and  
the backpanel signal ground can be made via R1. R1 can be as large as 10K  
ohms;100ohmsisarecommendedvalue. JumperJ2canbeusedtoconnect  
the SENSE line to R1 when this ground configuration is used.  
The OM5-BP-16-C backpanel power is fuse protected through F1. This is a  
Littlefuse type 252004, 4 amp fuse. Zener diode DZ1 provides extra  
protection by clamping the input power voltage to +5.6V. If the input supply  
voltage connection is reversed, this zener diode will be forward biased and Forfullprotectionagainstlargeelectricaldisturbancesonthefield-sideofthe  
fuse F1 will be blown.  
OM5 modules, a #10-32 ground stud is provided on the backpanel. An  
electricalconnectionbetweenthisgroundstudandsystemgroundshouldbe  
provided with a large gauge wire of the shortest possible length. When this  
connection is made, a possible ground loop could result through the AGND  
shield wires and backpanel signal ground. If the application involves only  
input modules and a differential input is used by the host measurement  
system, J1 should be removed. Remember that J1 is required if output  
modules are used or if the host system does not have differential inputs.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-16-MUX-C 16 POSITION ANALOG I/O BACKPANEL, MULTIPLEXED  
DESCRIPTION  
SPECIFICATIONS  
Operating Temperature:  
–40°C to +85°C  
The OM5-BP-16-MUX-C 16 channel backpanel (Figure 5) can accept any  
of the OM5 analog modules in any mixture. It can be mounted on the  
OMX-1363-C 19-inch metal rack. The OM5-BP-16-MUX-C has two  
analog buses; one for analog input and one for analog output. This two-  
bus configuration takes advantage of the switch controlled outputs on the  
input modules and the track-and-hold inputs on the output modules. A  
temperature sensor is mounted on each channel to provide cold junction  
compensation for thermocouple input modules (See Figure 6 for  
schematic). Field connections are terminated with four screw terminals at  
each module site. Up to four OM5-BP-16-MUX-C backpanels may be  
daisy-chained. Use OMX-CAB-01-C cable for daisy chaining and OMX-  
1315-XX-C cable for connecting to host computer.  
95% relative humidity, non-condensing  
Interface Connector:  
Field  
Logic  
High Density Screw Clamp, 14 AWG Max  
26-pin, male header connector  
Address Input Logic Levels:  
Max Logic “0”  
0.8V  
2.0V  
Min Logic “1”  
II Input Current, “0” or “1”  
0.1µA max at 25°C  
1.0µA max –25°C to +85°C  
RD EN\ or WR EN\ Signal Delay  
from Connector P1 to Channels 1-16  
Standalone (address 0-15)  
51ns at 25°C  
64ns at –25°C to +85°C  
100ns at 25°C  
Expanded (address 16-63)  
126ns at –25°C to +85°C  
17.4" (442.0mm)  
17.1" (434.3mm)  
11.3" (287.0mm)  
7.6" (193.0mm)  
3.9" (99.1mm)  
26 Conductor Male  
Pin Connector P1(1)  
0.15"  
(3.8mm)  
1.275"  
(32.4mm)  
3.47"  
P1  
(88.1mm)  
E2  
E1  
4
3
2
1
0
3.05"  
(77.5mm)  
10.32 X 0.40  
Ground Lug, Including  
Nut and Lockwasher  
OMX-CJC-C  
Cold Junction  
Compensation Circuit  
Write Address  
Selection Jumper  
Sockets for Current Conversion Resistors, OMX-1362-C  
Pin 2  
Pin 1  
+5VDC Supply  
Channel  
0.08"  
16  
(2.0mm)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Read Address  
Selection Jumper  
Swaged Standoff  
Thru Hole 0.15" (3.8mm) Dia.  
2.27"  
(57.7mm)  
0.093"  
(2.4mm)  
0.75" (19.1mm)  
0.14" (3.6mm)  
inside diameter  
NOTES:  
1. Connector is Berg 65863-075 or equivalent.  
Mating Connector is Amp 49958-6 or equivalent.  
FIGURE 5. OM5-BP-16-MUX-C Analog I/O Backpanel.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 6. OM5-BP-16-MUX-C Schematic.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GROUNDING  
ELECTRICAL  
Figure 7 below details the optional ground jumper configuration available on  
the OM5-BP-16-MUX-C backpanel. Jumpers J1, J2, and J4 are factory  
installed.  
P1 CONNECTOR  
The 26 pin P1 connector provides the signal interface between the OM5-BP-  
16-MUX-C backpanel and the host measurement system. Two separate  
analog bus connections are provided; one for analog input signals and one  
for analog output signals. Two sets of six address lines and an enable pin  
allow input and output modules to be independently multiplexed onto their  
respective analog signal bus. R0 thru R5 and RDENAB are used for input  
modules, and W0 thru W5 and WRENAB are used for output modules.  
Jumper J1 connects the SIG COM shield wires (pins 2, 5, and 6) to the  
backpanel signal ground. This provides a ground connection between the  
host system and backpanel. Jumper J1 is required if output modules are  
used, or if there is no high impedance sense input (input low of a differential  
or pseudo-differential system) on the host measurement system.  
Jumper J2 connects the SNS LO line (pin 4) to the backpanel signal ground.  
If the host system has the capability, this allows measuring the OM5-BP-16-  
MUX-C ground potential.  
ADDRESS SELECTION  
The OM5-BP-16-MUX-C backpanel has address decoding circuitry to allow  
multiplexinganycombinationofupto16inputoroutputmodules. Capability  
is also provided in the address decode circuitry to expand the system to 64  
channels (four OM5-BP-16-MUX-C backpanels) of multiplexed input or  
output. Jumpers on HD10 header, E1 and E2 group, select which set of 16  
addresses are assigned to a particular backpanel. The E1 group assigns a set  
of 16 addresses for input modules, and the E2 group assigns a set of 16  
addresses for output modules. The table below shows the correlation of  
jumper position to address range.  
For proper operation of the output switch or track-and-hold circuit when  
usingtheOM5-BP-16backpanels, acurrentpathmustexistbetweenthehost  
controllogicpowercommonandmoduleI/OCommon(modulepin19). This  
path can be established on the OM5-BP-16-MUX-C via jumper J4. If this  
connection exists elsewhere in the system, jumper J4 should be removed  
sincepossiblegroundloopscouldexist. Otherconnectionsofpowerground  
and signal ground usually occur at the A/D or D/A converter of the host  
measurement system.  
E1 Jumper Pos  
E2 Jumper Pos  
Address Range/Mode  
If the connection of power common and SIG COM shield wires exist in the  
host measurement system, a resistive connection between SIG COM and the  
backpanel signal ground can be made via R1. R1 can be aslargeas 10K ohms;  
100 ohms is a recommended value. Jumper J3 can be used to connect the  
SNS LO line to R1 when this ground configuration is used.  
4
3
2
1
0
4
3
2
1
0
0-15, STAND ALONE  
48-63, EXPANDED  
32-47, EXPANDED  
16-31, EXPANDED  
0-15, EXPANDED  
Forfullprotectionagainstlargeelectricaldisturbancesonthefield-sideofthe  
OM5 modules, a #10-32 ground stud is provided on the backpanel. An  
electricalconnectionbetweenthisgroundstudandsystemgroundshouldbe  
provided with a large gauge wire of the shortest possible length. When this  
connection is made, a possible ground loop could result through the SIG  
COM shield wires and backpanel signal ground. If the application involves  
only input modules and a differential input is used by the host measurement  
system, J1 should be removed. Remember that J1 is required if output  
modules are used or if the host system does not have differential inputs.  
To connect multiple OM5-BP-16-MUX-C backpanels in this expanded  
configuration, use interconnect cable OM5-CAB-01-C.  
POWER  
The OM5-BP-16-MUX-C backpanel requires external +5VDC 5% power.  
The chassis mounted OMX-976 power supplies have adequate capacity to  
power any combination of modules.  
FUSING  
The OM5-BP-16-MUX-C backpanel power is fuse protected through F1.  
This is a Littlefuse type 252004, 4 amp fuse. Zener diode DZ1 provides extra  
protection by clamping the input power voltage to +5.6V. If the input supply  
voltage connection is reversed, this zener diode will be forward biased and  
fuse F1 will be blown.  
P1  
OM5 Module  
2
5
6
4
SIG COM  
SIG COM  
SIG COM  
SIG COM  
I/O COM 19  
16 PWR COM  
J2  
J1  
J4  
J3  
Power Common  
Signal Ground  
R
1
and  
Grounding Bolt  
FIGURE 7. OM5-BP-16-MUX-C Grounding Diagram.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-SKT-C /-2-C ONE / TWO POSITION ANALOG I/O BACKPANELS  
DESCRIPTION  
SPECIFICATIONS  
Operating Temperature:  
–40°C to +85°C  
The OM5-BP-SKT-C is a single channel mounting panel for the OM5  
modules. The OM5-BP-2-C is a dual channel mounting panel for the OM5  
modules. They both are DIN rail compatible.  
95% relative humidity, non-condensing  
Interface Connector:  
Field  
Logic  
High Density Screw Clamp, 14 AWG Max  
High Density Screw Clamp, 14 AWG Max  
See Figures 9 and 10 for wiring diagrams, Figures 11 and 12 for schematics.  
The following accessories are required for mounting one OM5-BP-SKT- or  
-2-C panel (Figure 8):  
Qty  
Model  
Description  
1
2
OM7-DIN-SF  
OM7-DIN-SE  
Base element with snap foot  
Side element  
The following accessories are required for mounting two or more OM5-BP-  
SKT- or -2-C panels:  
DIN Rail  
mounts to DIN rails  
EN 50022-35x7.5  
EN 50022-35x15  
EN 50035-G32  
Qty  
Model  
Description  
2
2
OM7-DIN-SF  
OM7-DIN-SE  
Base element with snap foot  
Side element  
(# panels)-2  
(4 x (# panels))-4 OM7-DIN-CP  
OM7-DIN-WSF Base element without snap foot  
Connection pins  
OM7-DIN-SE  
OM7-DIN-SF  
OM7-DIN-CP  
OM7-DIN-WSF  
The following DIN rail styles are available. Specify length in meters (-XX)  
EN 50022-35x7.5 (slotted steel)  
EN 50035-G32 (slotted steel)  
EN 50022-35x15 (slotted steel)  
OM7-DIN-SE  
FIGURE 8. DIN Rail Mounting Elements.  
Sockets for Current Conversion Resistor, OMX-1362-C  
OMX-CJC-C Cold Junction  
Compensation Circuit  
J1  
–EXC  
–In/–Out  
Power Common  
+5V  
+In/+Out  
+EXC  
I/O COM/–IIN  
VIN/VOUT/+IIN  
TB1  
TB2  
Isolated I/O  
Local I/O  
4.25"  
(108mm)  
FIGURE 9. OM5-BP03-C Wiring Diagram.  
Sockets for Current Conversion Resistor, OMX-1362-C  
OMX-CJC-C Cold Junction  
Compensation Circuit  
TB1  
TB3  
3
4
1
2
Power Common  
+5V  
Channel A  
I/O COM/–IIN  
VIN/VOUT /+IIN CH A  
V
IN/VOUT /+IIN CH B  
Channel B  
1
2
3
4
Local I/O  
TB2  
TB4  
Isolated I/O  
4.25"  
(108mm)  
FIGURE 10. OM5-BP04-C Wiring Diagram.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I/O VIN  
/
COM/ VOUT/  
–IIN +IIN  
PCOM +5V  
TB2  
4
3
2
1
J1  
LED  
WR EN\ 23  
DATA 21  
I/O COM 19  
22 RD EN\  
20 VOUT  
18 VIN  
17  
+5V  
16 PCOM  
6
4
2
+In  
+EXC  
+SEN  
–In  
–EXC  
–SEN  
5
3
1
OMX-CJC-C  
OMX-1362-C  
TB1  
1
2
3
4
–EXC –In/ +In/ +EXC  
–Out +Out  
VIN  
/
VIN/  
VOUT/ VOUT  
/
I/O  
COM/  
–IIN  
–IIN –IIN  
CH A CH B  
FIGURE 11. OM5-BP-SKT-C Schematic.  
PCOM +5V  
TB3  
2
1
TB4  
3
2
1
J2  
LED  
WR EN\ 23  
DATA 21  
I/O COM 19  
WR EN\ 23  
DATA 21  
I/O COM 19  
+5V17  
22 RD EN\  
20 VOUT  
18 VIN  
22 RD EN\  
20 VOUT  
18 VIN  
17  
+5V  
16 PCOM  
16 PCOM  
6
4
2
+In  
+EXC  
+SEN  
6
4
2
+In  
+EXC  
+SEN  
–In  
–EXC  
–SEN  
5
3
1
–In  
–EXC  
–SEN  
5
3
1
OMX-CJC-C  
OMX-CJC-C  
OMX-1362-C  
OMX-1362-C  
*NOTE: OMX-1362-C resistors are  
not installed at factory.  
TB1  
1
2
3
4
TB2  
1
2
3
4
–EXC –In/ +In +EXC  
–Out +Out  
–EXC –In +In +EXC  
–Out +Out  
Channel A  
Channel B  
FIGURE 12. OM5-BP-2-C Schematic.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-8-C 8 POSITION ANALOG I/O BACKPANEL, NON-MULTIPLEXED  
A temperature sensor is mounted on each channel to provide cold junction  
compensationforthermocoupleinputmodules(SeeFigure14forSchematic-  
DESCRIPTION  
The OM5-BP-8-C analog module mounting board has a capacity of eight  
analog input and/or output modules in any combination. It can be mounted  
on the OMX-1363-C 19-inch metal rack. A separate analog signal path is  
provided for each channel and each channel’s signal is accessible at  
redundant 26-pin connectors. The module output switch is continuously  
“on” when using this backpanel and all eight module outputs are simulta-  
neously accessible to high-speed data acquistion (ADC) boards.  
SPECIFICATIONS  
On-board jumpers permit paralleling two OM5-BP-8-C boards to form a  
OM5-BP-16-C equivalent. An additional set of inter-channel bridge jumpers  
permits connecting an input module’s output to an output module’s input,  
providing two levels of isolation (Figures 13, 14).  
Operating Temperature:  
–40°C to +85°C  
95% relative humidity, non-condensing  
Interface Connector:  
Field  
Logic  
High Density Screw Clamp, 14 AWG Max  
26-pin, male header connector  
Jumpers on the OM5-BP-8-C permit user selection of low (i.e. channels 0-  
7) or high (i.e. channels 8-15) addresses.  
10.0"  
Tolerance: 0.020" ( 0.50mm)  
(254.0mm)  
9.7"  
(246.3mm)  
9.5"  
(241.3mm)  
26 Conductor  
Male Pin  
5.8"  
(147.3mm)  
Connectors P1, P2(1)  
0.15"  
(3.8mm)  
10.32 X 0.40  
Ground Lug, Including  
Nut and Lockwasher  
L H  
J12  
P1 P2  
JP7  
JP1  
Swaged  
Standoff  
Thru Hole  
0.15" (3.8mm) Dia.  
(6)  
J5  
J4  
J1 J2 J3  
OMX-CJC-C  
Cold Junction  
Compensation Circuit  
0.75"  
(19.1mm)  
+5VDC Supply  
Pin 2  
Sockets for Current  
Conversion Resistors, OMX-1362-C  
Barrier Strips for  
Field Analog Signal  
I/O Termination. (8)  
Pin 1  
Pin 2  
Pin 1  
2.25"  
(57.2mm)  
3.15"  
(80.2mm)  
NOTES: (1) Connector is Berg 65863-075 or equivalent.  
Mating connector is AMP 49958-6 or equivalent.  
Connectors P1 and P2 are wired in parallel for  
“Daisy Chaining” up to 8 boards.  
FIGURE 13. OM5-BP-8-C Analog I/O Backpanel.  
ELECTRICAL  
ADDRESS SELECTION  
ADJACENT CHANNEL JUMPERS  
Module addresses may be selected as low (channels 0-7) or high (channels Adjacent channels may be connected together to provide an isolated output  
8-15) using the sets of 3 pins labeled J5 through J12. Place a jumper over signal from an isolated input module, providing two levels of 1500V  
thetwopinsclosesttotheribboncableconnectors, P1andP2, toselectalow isolation. This capability is provided with the seven jumpers labeled JP1–  
address (factory configuration) or over the two pins furthest from the ribbon JP7.  
cable connectors, P1 and P2, to select a high address.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE14.OM5-BP-8-CSchematic.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-8-MUX-C 8 POSITION ANALOG I/O BACKPANEL, MULTIPLEXED  
DESCRIPTION  
SPECIFICATIONS  
Operating Temperature:  
–40°C to +85°C  
The OM5-BP-8-MUX-C backpanel (Figure 15) can accept up to eight OM5  
modulesinanycombination. ItcanbemountedontheOMX-1363-C19-inch  
metal rack. The OM5-BP-8-MUX-C has two analog buses; one for analog  
input and one for analog output. This two-bus configuration takes advantage  
of the switch controlled outputs on the input modules and the track-and-hold  
inputs on the output modules. A temperature sensor is mounted on each  
channel to provide cold junction compensation for thermocouple input  
modules (See Figure 16 for schematic). Field connections are terminated  
with four screw terminals at each module site. Up to eight OM5-BP-8-MUX-  
C backpanels may be daisy-chained. Use OMX-CAB-01-C cable for daisy  
chaining and OMX-1315-xx-C cable for connecting to host computer.  
95% relative humidity, non-condensing  
Interface Connector:  
Field  
Logic  
High Density Screw Clamp, 14 AWG Max  
26-pin, male header connector  
Address Input Logic Levels:  
Max Logic “0”  
0.8V  
2.0V  
Min Logic “1”  
II Input Current, “0” or “1”  
0.1µA max at 25°C  
1.0µA max –25°C to +85°C  
Jumpers on the OM5-BP-8-MUX-C permit user selection of low (i.e.  
channels 0-7) or high (i.e. channels 8-15) addresses.  
RD EN\ or WR EN\ Signal Delay  
from Connector P1 to Channels 0-7  
Standalone (address 0-7)  
51ns at 25°C  
64ns at –25°C to +85°C  
100ns at 25°C  
126ns at –25°C to +85°C  
Expanded (address 8-63)  
10.0"  
(254.0mm)  
Tolerance: 0.020" ( 0.50mm)  
9.7"  
(246.3mm)  
9.5"  
(241.3mm)  
5.8"  
(147.3mm)  
26 Conductor  
Male Pin Connector P1(1)  
0.15"  
(3.8mm)  
P2  
1
P3  
6
J7  
10.32 X 0.40  
Ground Lug, Including  
Nut and Lockwasher  
P1  
J8  
J6  
L
H
J5  
J4  
Swaged  
Standoff  
L
H
J1 J2 J3  
Thru Hole  
0.15" (3.8mm) Dia.  
(6)  
OMX-CJC-C  
Cold Junction  
Compensation Circuit  
0.75"  
(19.1mm)  
Pin 2  
Pin 1  
+5VDC Supply  
Sockets for Current  
Conversion Resistors, OMX-1362-C  
Barrier Strips for  
Field Analog Signal  
I/O Termination. (8)  
Read Address  
Selection Jumper  
2.25"  
(57.2mm)  
Write Address  
Selection Jumper  
NOTES: (1) Connector is Berg 65863-075 or equivalent.  
Mating connector is AMP 49958-6 or equivalent.  
3.15"  
(80.2mm)  
FIGURE 15. OM5-BP-8-MUX-C Analog I/O Backpanel.  
backpanel. The Read Address group assigns a set of 16 addresses for input  
modules, and the Write Address group assigns a set of 16 addresses for  
output modules. The table below shows the correlation of jumper position to  
address range.  
ELECTRICAL  
ADDRESS SELECTION  
Module read and write addresses may be selected as low (channels 0-7) or  
high (channels 8-15) using the four sets of 3 position jumpers labeled J5  
through J8. Place a jumper over the two pins furthest from the field I/O  
termination blocks on all four sets to select a low address (factory configu-  
ration) or over the two pins closest to the field I/O termination blocks on all  
four sets to select a high address.  
Address Selection Jumpers  
Read Address  
Jumper(P2)  
Write Address  
Jumper(P3)  
Address  
Range  
1
2
3
4
5
6
7
8
9
10  
0-15 Stand alone  
48-63 Expanded  
32-47 Expanded  
16-31 Expanded  
0-15 Expanded  
The OM5-BP-8-MUX-C backpanel has address decoding circuitry to allow  
multiplexing any combination of up to 8 input or output modules. Capability  
is also provided in the address decode circuitry to expand the system to 64  
channels (eight OM5-BP-8-MUX-C backpanels) of multiplexed input or  
output. Jumpers select which set of 16 addresses are assigned to a particular  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 16. OM5-BP-8-MUX-C Schematic.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-16-DIN-C, OM5-BP-16-MUX-DIN-C, OM5-BP-8-DIN-C,  
OM5-BP-8-MUX-DIN-C  
SCMXSE DIN rail mounting elements. The SCMPB0X-2 comes fully as-  
sembled.  
DESCRIPTION  
The SCMPB0X-2 is the SCMPB0X backpanel with a DIN rail mounting  
option. The SCMPB0X backpanel is attached to a 0.062" thick piece of black  
anodized aluminum, which in turn is captured using the SCMXBEFE and  
OMX-1363-C 19 INCH METAL MOUNTING RACK  
DESCRIPTION  
The OMX-1363-C is a 19-inch metal rack for mounting the OM5-BP backpanels. It also provides capability to mount the PMX-976-C power supplies, and  
the OMX-1324-C interface board (See Figure 17 for dimensions).  
17.60" (447.04mm)  
3.62" (91.95mm)  
3.12" (79.25mm)  
0.31" (7.87mm)  
1.375" (34.93mm) 2 PL  
0.125" (3.17mm) 2 PL  
0.062" (1.57mm)  
0
0.63" 0  
(16.00mm)  
17.29" 18.23"  
(439.16mm) (463.04mm)  
Cable Access Cutout  
Left Side Only  
3.480" (88.39mm)  
3.378" (85.80mm)  
3.103" (78.82mm)  
3.265  
(82.93mm)  
3.00"  
(76.2mm)  
0.141" (3.58mm) Dia 8 PL  
3mm metric  
PEM nut 7 PL  
0.50"  
(12.7mm)  
0.378" (9.60mm)  
0.103" (2.62mm)  
0
0.215"  
(5.46mm)  
0
0
1.10"  
2.60"  
(27.94mm) (66.04mm)  
FIGURE 17. OMX-1363-C Analog Rack Dimensions.  
OMX-1324-C UNIVERSAL INTERFACE BOARD  
DESCRIPTION  
The OMX-1324-C is a universal interface board which converts a 26-pin ribbon cable input to 26 screw terminals for discrete wire. It can be mounted on  
the back of the OMX-1363-C mounting rack or on a DIN rail. Required mounting hardware is included. Use OMX-1315-xx-C cable (See Figure 18 for  
dimensions).  
4.00"  
(101.6mm)  
2
4
6
8
10 12 14 16 18 20 22 24 26  
2
2.20"  
(55.9mm)  
1
1
3
5
7
9
11 13 15 17 19 21 23 25  
1.90"  
(48.3mm)  
FIGURE 18. OMX-1324-C Universal Interface Board Dimensions.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-BP-SKT-C ANALOG MODULE EVALUATION BOARD  
DESCRIPTION  
2.85"  
The OM5-BP-SKT-C is a single channel board with a test socket for OM5  
module evaluation (Figure 19). All signal input/output, control, and power  
connections are connected to terminal blocks for ease of user access. A cold  
junction temperature sensor circuit is included for evaluation of thermo-  
couple modules. (See Figure 20 for schematic).  
(72.4mm)  
0.25" (6.4mm) Typical  
0.25"  
(6.4mm)  
Typical  
Control  
Local I/O  
RD EN\  
VOUT  
The OM5-BP-SKT-C is mechanically compatible with DIN rail mounting  
using the following elements:  
WR EN\  
Reserved  
PCOM  
I/O COM  
VIN  
2 OM7-DIN-SF base elements with snap foot  
2 OM7-DIN-SE side elements  
4 OM7-DIN-CP connection pins  
I/O COM  
TB1  
TB3  
TB2  
J1  
+5V  
4.25"  
(108mm)  
PCOM  
+
Two jumpers are provided for customer use. The first, J1, provides a current  
path between +5V Power Common (module pin 16) and I/O Common  
(module pin 19). A path must exist between the host control logic power  
common and module I/O Common for proper operation of the module output  
switch or track-and-hold circuit. If this connection exists elsewhere in the  
system, jumper J1 should be removed since possible ground loops could  
exist. Other connections of power ground and signal ground usually occur  
at the A/D or D/A converter of the host measurement system.  
CJC  
J2  
OMX-1362-C  
OMX-CJC-C  
TB4  
Jumper J2 is used in the cold junction compensation circuit. If it is installed,  
the compensation circuit is enabled and will provide the proper compensa-  
tion voltage to correct for the thermoelectric effect at the +In and –In screw  
terminals. If an external simulation voltage is desired for cold junction  
compensation, J2 should be removed. The external voltage is applied at the  
socketslabledCJC+andCJC–.Anexternalvoltageof510.0mVcorresponds  
to an ambient temperature of +25 °C. The transfer function of the onboard  
compensation circuit is VCJC = 0.510 –0.0025(T–25)V.  
–EXC  
–In  
+EXC  
+In  
FIGURE 19. OM5-BP-SKT-C Evaluation Board Dimensions And Pin Layout.  
23  
21  
19  
17  
TB1  
RD EN\  
WR EN\  
Reserved  
PCOM  
TB2  
22  
20  
18  
16  
VOUT  
I/O COM  
VIN  
I/O COM  
OM5  
PCOM  
I/O COM  
6 +In  
4 +EXC  
2 +SEN  
PCOM  
–In 5  
–EXC 3  
–SEN 1  
J1  
+5  
PCOM  
I/O COM  
TB3  
J2  
+
CJC  
PCOM  
DZ1  
LED  
OMX-CJC-C  
PCOM  
OMX-1362-C  
NOTES:  
1. J1 and J2 are factory installed.  
2. SCMXCJC is a CJC temperature sensor.  
3. Resistor SCMXR1 is an optional I/V conversion  
resistor for current inputs, not factory installed.  
TB4  
–EXC –In +In +EXC  
FIGURE 20. OM5-BP-SKT-C Evaluation Board Schematic.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-1315-XX-C, OMX-CAB-01-C INTERFACE CABLES  
DESCRIPTION  
OM5-1315-XX-C  
OMX-CAB-01-C  
System interface cable for the SCMPB01/02/05/06 backpanels. This is a 26  
conductorribboncablewithamass-terminatedsocketconnectorinstalledon  
each end. It can be ordered in any length; -xx denotes required length in  
meters (Figure 21).  
Daisy-chain cable provides interconnection between a maximum of four  
OM5-BP-16-MUX-C and eight OM5-BP-8-MUX-C backpanels (See Figure  
22).  
Colored Stripe on  
Cable is Assembled to  
Pin 1 of Connectors  
Colored Stripe on  
Cable is Assembled to  
Pin 1 of Connectors  
Socket  
Connector  
Socket  
Connector  
Socket  
Connector  
Socket  
Connector  
Pin Connector  
Pin 1  
Pin 1  
Cable  
Pin 1  
Cable  
Pin 1  
Pin 1  
–XX, Lenglth in Meters  
1 Meter (3.3 feet)  
FIGURE 21. OMX-1315-XX-C System Interface Cable.  
FIGURE 22. OMX-CAB-01-C Daisy-Chain Cable.  
OMX-CAB-01-C  
OM5-BP-8 or 16-MUX-C  
OM5-BP-8 or 16-MUX-C  
OM5-BP-8 or 16-MUX-C  
OMX-CAB-01-C  
OMX-CAB-01-C  
OM5-BP-8 or 16-MUX-C  
TO HOST  
SYSTEM  
OMX-1315-XX-C  
Up to eight OM5-BP-8-MUX-C backpanels  
FIGURE 23. Application Of OMX-CAB-01-C Daisy-Chain Cable.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OMX-CJC-C ENCAPSULATED COLD JUNCTION COMPENSATION  
0.60"  
(15.2mm)  
0.30"  
(7.6mm)  
DESCRIPTION  
The OMX-CJC-C is the identical circuit used on the OM5-BP backpanels  
except it is packaged as a component for use in customer designed mounting  
boards(Figure24).WheninterfacedtoanOM5-ITCorOM5-LTCmodule,the  
transferfunctionofthevoltageacrossthe+SENandSENpinsisVCJC =0.510  
–0.0025(T –25)V.  
0.50"  
(12.7mm)  
Side  
Side  
0.10" – 0.15"  
(2.5 – 3.8mm)  
0.15" (3.8mm)  
0.03" (0.76mm)  
0.35" (8.9mm)  
0.45" (11.4mm)  
SPECIFICATIONS  
Accuracy +25°C  
+5°C to +45°C  
–40°C to +85°C  
0.25°C  
0.5°C  
1.25°C  
Pin Width = 0.020" (0.51mm)  
(Recommended PCB  
hole size of 0.031")  
–EXC  
–SEN +SEN  
Bottom  
FIGURE 24. OMX-CJC-C Physical Dimensions And Pin Layout.  
OMX-1344 JUMPERS  
DESCRIPTION  
Package of 10 jumpers for connecting adjacent input/output modules on the OM5-BP-16-C backpanel. This connection is made if it is desired to direct  
the output of any input module to the input of an adjacent output module. The jumpers can also be used for configuring I/O addresses on the OM5-BP-  
16-MUX-C backpanel.  
OMX1362-C CURRENT CONVERSION RESISTOR  
0.50"  
(12.7mm)  
0.15"  
(3.8mm)  
DESCRIPTION  
A precision 20Ω, 0.1%, 10ppm/°C resistor used with the OM5-II current  
input module or OM5-TX two-wire transmitter interface module (Figure 25).  
Sockets are provided on all backpanels to allow installation of this resistor.  
One OMX-1362-C is shipped with each module.  
0.50"  
(12.7mm)  
Side  
Side  
0.075"  
(1.9mm)  
0.05" (1.3mm)  
0.45" (10.2mm)  
Pin Width = 0.040" (1.02mm)  
Bottom  
FIGURE 25. OMX-1362-C Physical Dimensions.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OMX-955-C, OMX-955-220-C POWER SUPPLIES  
DESCRIPTION  
The OMX-955-C encapsulated power supplies are available in 120VAC or  
220VAC input voltage ranges and provide 5VDC outputs suitable for all OM5  
modules. They are designed to mount on the OMX-1363-C metal rack. The  
supplies are UL-recognized and CSA certified. Their compact size and low  
weight are ideal for high-density applications (see Figure 25.)  
SPECIFICATIONS  
OMX-955-C  
OMX-955-220-C  
Input Voltage Range  
Output Voltage  
Output Current, +50°C  
(derate 2.5%/°C above +50°C)  
Operating Temp  
Dielectric Withstand Voltage (Input to Ground)  
Line Regulation  
105-125VAC  
5VDC  
200-240VAC  
5VDC  
1A  
1A  
-25°C to +71°C  
2500VRMS  
0.05%  
-25°C to +71°C  
2500VRMS  
0.05%  
Load Regulation  
Output Ripple, max  
0.15%  
2mVRMS  
0.15%  
2mVRMS  
Overvoltage Protection, nominal  
Weight  
6.2V  
6.2V  
1.25 lbs (567 grams)  
1.25 lbs (567 grams)  
Supplies are UL recognized, File No. E65890, and CSA certified, File No. LR59996.  
0.75"  
(19.1mm)  
5.40 BH  
Screws  
0.75"  
(19.1mm)  
AC  
AC  
NC  
2.50"  
4.00"  
NC  
Inserts  
4.40 Thread  
(63.5mm) (101.6mm)  
.125" (3.2mm) deep  
COM  
+OUT  
1.45" (36.8mm)  
2.00" (50.8mm)  
2.70" (68.6mm)  
0.35"  
(8.9mm)  
FIGURE 25. OMX-955/955-220-C Physical Dimensions.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OMX-977-C, OMX-977-220-C POWER SUPPLIES  
DESCRIPTION  
The OMX-977 Linear Power Supplies are available in 120VAC or 220VAC  
input. Theyhavesufficientoutputcurrentcapacitytosupplyanycombination  
ofOM5modules. TheOMX-1363-Cmetalrackprovidesmountingcapability  
for the power supplies (See Figure 26).  
SPECIFICATIONS  
OMX-977-C  
OMX-977-220-C  
Input Voltage Range  
Output Voltage  
104-132VAC  
5VDC 1%  
3A  
207-265VAC  
5VDC 1%  
3A  
Output Current (at +70°C)  
Output Current (at +50°C)  
Operating Temp  
Dielectric Withstand Voltage (input to ground)  
Line Regulation (10% line change)  
Load Regulation (50% load change)  
Output Ripple (max)  
6A  
6A  
0 to +70°C  
3750VAC  
0.05%  
0.05%  
5 mVP-P  
0 to +70°C  
3750VAC  
0.05%  
0.05%  
5 mVP-P  
Overvoltage Protection (factory set)  
6.2 V 0.4V  
6.2 V 0.4V  
Both supplies are tested and certified by TUV to VDE 0806 and IEC 380. They are UL Recognized (File Number E55974) and CSA Certified  
(CSA File Number LR38879).  
0.50"  
(12.7mm)  
0.15"  
(3.8mm)  
0.50"  
(12.7mm)  
Side  
Side  
0.075"  
(1.9mm)  
0.05" (1.3mm)  
0.45" (10.2mm)  
Pin Width = 0.040" (1.02mm)  
Bottom  
FIGURE 26. OMX-977/977-220-C Physical Dimensions.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTION GUIDE FOR OM5 ISOLATED  
SIGNAL CONDITIONING PRODUCTS  
General Description  
ANALOG VOLTAGE INPUT MODULES, NARROW BANDWIDTH (4Hz BW)  
OMEGA® OM5 Series Isolated Signal Conditioning Modules are low cost,  
high performance, plug-in signal conditioners. Each OM5 module provides  
a single channel of isolated analog input or output. Input modules interface  
to all types of external sensors. The modules filter, isolate, amplify, and  
convert the input signal to a high-level analog voltage output. The output  
modules accept a high-level analog voltage signal from a host system, then  
buffer, isolate, and amplify before providing a process current or voltage  
output to field devices. Over 115 different OM5 modules are available  
encompassingawideselectionofisolatedanaloginputandoutputfunctions.  
Analog inputs include voltage and current in narrow and wide bandwidths,  
Thermocouple, RTD, Potentiometer, Strain Gage, Frequency, and 2-Wire  
Transmitter. Custom I/O ranges are also available. All modules are CSA  
certified and FM approved for safe operation in Class I, Division 2, Groups  
A, B, C, and D hazardous environments.  
MODEL INPUT RANGE  
OUTPUT RANGE*  
OM5-IMV-10A-C 10mV  
OM5-IMV-50A-C 50mV  
OM5-IMV-100A-C 100mV  
OM5-IMV-10B-C 10mV  
OM5-IMV-50B-C 50mV  
OM5-IMV-100B-C 100mV  
5V  
5V  
5V  
0 to +5V  
0 to +5V  
0 to +5V  
OM5-IV-1A-C  
OM5-IV-5A-C  
OM5-IV-10A-C  
OM5-IV-1B-C  
OM5-IV-5B-C  
OM5-IV-10B-C  
OM5-IV-20A-C  
OM5-IV-20B-C  
OM5-IV-40A-C  
OM5-IV-40B-C  
1V  
5V  
5V  
5V  
10V  
1V  
5V  
10V  
20V  
20V  
40V  
40V  
5V  
0 to +5V  
0 to +5V  
0 to +5V  
5V  
0 to +5V  
5V  
0 to +5V  
ANALOG CURRENT INPUT MODULES, 4Hz AND 1kHz BANDWIDTH  
MODEL  
INPUT RANGE  
OUTPUT RANGE*  
BW  
Accessories include: addressable and non-addressable single, dual, eight  
and 16 channel backpanels, available with on-board temperature sensors  
and cold junction thermocouple compensation; power supplies; mounting  
racks; interface cables, and evaluation boards.  
OM5-II-4/20-C  
OM5-II-0/20-C  
4 to 20mA  
0 to 20mA  
0 to +5V  
0 to +5V  
4Hz  
4Hz  
TRUE RMS INPUT MODULES  
MODEL  
INPUT RANGE (rms)  
OUTPUT RANGE (dc)  
OM5-IAC-100B-C  
OM5-IAC-1B-C  
OM5-IAC-10B-C  
0 to 100mV  
0 to 1V  
0 to 10V  
0 to +5V  
0 to +5V  
0 to +5V  
OM5 modules offer several advantages when compared with competitive  
parts, while maintaining equivalent price:  
LINEARIZED 2- OR 3-WIRE RTD INPUT MODULES (0 to +5V OUTPUT*,  
4Hz BW)  
50 times better noise rejection by using a 6-pole filter with 95dB  
NMR, versus a three-pole filter with 60dB NMR; • Lower output noise  
• True 3-way isolation • CMR of noise spikes measures 20dB better  
than competing models.  
MODEL  
TYPE***  
INPUT RANGE  
OM5-IP-N100-C  
OM5-IP-100-C  
OM5-IP-200-C  
OM5-IP-600-C  
100Pt  
100Pt  
100Pt  
100Pt  
–100°C to +100°C (–148°F to +212°F)  
0°C to +100°C (+32°F to +212°F)  
0°C to +200°C (+32°F to +392°F)  
0°C to +600°C (+32°F to +1112°F)  
Key Specifications  
• 1500V Isolation  
OM5-IC-120-01-C 10Cu at 0°C  
0°C to +120°C (+32°F to +248°F)  
OM5-IC-120-02-C 10Cu at 25°C 0°C to +120°C (+32°F to +248°F)  
OM5-IN-300-C  
120Ni  
0°C to +300°C (+32°F to +572°F)  
• Accuracy, 0.05%  
• CMR, 160dB  
• NMR, 95dB  
• Transient Protection, ANSI/IEEE C37.90.1-1989  
LINEARIZED 4-WIRE RTD INPUT MODULES (0 to +5V OUTPUT*, 4Hz BW)  
MODEL  
TYPE***  
INPUT RANGE  
OM5-IP4-N100-C 100Pt  
–100°C to +100°C (–148°F to +212°F)  
0°C to +100°C (+32°F to +212°F)  
0°C to +200°C (+32°F to +392°F)  
0°C to +600°C (+32°F to +1112°F)  
0°C to +120°C (+32°F to +248°F)  
OM5-IP4-100-C  
OM5-IP4-200-C  
OM5-IP4-600-C  
100Pt  
100Pt  
100Pt  
OM5-IC4-120-01-C 10Cu at 0°C  
1µV/°C Drift  
OM5-IC4-120-02-C 10Cu at 25°C 0°C to +120°C (+32°F to +248°F)  
OM5-IN4-300-C 120Ni 0°C to +300°C (+32°F to +572°F)  
• Output noise as low as 150µVrms  
• 240VAC Protection for field I/O  
• Operating temp range, –40°C/+85°C  
• CSA CERTIFIED (Class  
• FM APPROVED (Class  
POTENTIOMETER INPUT MODULES (4Hz BW)  
MODEL INPUT RANGE OUTPUT RANGE*  
OM5-PT-100-C 0 to 100Ω  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
OM5-PT-500-C 0 to 500Ω  
I
, Division 2, Groups A, B, C, D)  
OM5-PT-1K-C  
0 to 1KΩ  
I, Division 2, Groups A, B, C, D)  
OM5-PT-10K-C 0 to 10KΩ  
THERMOCOUPLE INPUT MODULES (0 to +5V OUTPUT*, 4Hz BW)  
• EUROPEAN EMC DIRECTIVE COMPLIANT  
• CE APPROVAL for low voltage directive not applicable.  
Products comply with ENG1010-1 (IEC1010)  
MODEL  
TYPE**  
INPUT RANGE  
OM5-ITC-J-C  
OM5-ITC-K-C  
OM5-ITC-T-C  
OM5-ITC-E-C  
OM5-ITC-R-C  
OM5-ITC-S-C  
OM5-ITC-B-C  
OM5-ITC-C1-C  
OM5-ITC-N1-C  
J
–100°C to +760°C (–148°F to +1400°F)  
–100°C to +1350°C (–148°F to +2462°F)  
–100°C to +400°C (–148°F to +752°F)  
0°C to +900°C (+32°F to +1652°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1800°C (+32°F to +3272°F)  
+350°C to +1300°C (+662°F to +2372°F)  
-100°C to +1300°C (-148°F to +2372°F)  
K
T
E
R
S
B
C
N
Applications  
• DESIGNED FOR INDUSTRIAL PLANT ENVIRONMENTS  
• PROTECTS USER EQUIPMENT FROM LIGHTNING AND HEAVY  
EQUIPMENT POWER-LINE VOLTAGE  
• REDUCES ELECTRICAL NOISE IN MEASURED SIGNALS  
• CONVENIENT SYSTEM EXPANSION AND REPAIR  
STRAIN GAGE INPUT MODULES ( 5V OUTPUT*, 10kHz BW)  
MODEL INPUT  
EXCITATION  
OM5-WBS38-01-C 10mV Full Bridge Input, (3mV/V) 100 to 10kΩ  
OM5-WBS-1-C 30mV Full Bridge Input, (3mV/V) 300 to 10KΩ  
3.333V  
10.000V  
3.333V  
OM5-WBS38-03-C 10mV Half Bridge Input, (3mV/V) 100 to 10kΩ  
OM5-WBS-3-C  
OM5-WBS-2-C  
OM5-WBS-4-C  
OM5-WBS-5-C  
30mV Half Bridge Input, (3mV/V) 300 to 10KΩ  
10.000V  
10.000V  
20mV Full Bridge Input, (2mV/V) 300 to 10KΩ  
33.3mV Full Bridge Input, (10mV/V) 100 to 10K3.333V  
100mV Full Bridge Input, (10mV/V) 300 to 10K10.000V  
ANALOG CURRENT OUTPUT MODULES, 400Hz AND 1kHz BANDWIDTH  
MODEL  
INPUT RANGE  
OUTPUT RANGE  
BW  
OM5-IVI-B4-C  
OM5-IVI-A4-C  
OM5-IVI-B0-C  
OM5-IVI-A0-C  
0 to +5V  
5V  
0 to +5V  
5V  
4 to 20mA  
4 to 20mA  
0 to 20mA  
0 to 20mA  
400Hz  
400Hz  
400Hz  
400Hz  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTION GUIDE FOR OM5 ISOLATED SIGNAL CONDITIONING PRODUCTS  
ANALOG VOLTAGE INPUT MODULES, WIDE BANDWIDTH (10kHz BW)  
VOLTAGE OUTPUT MODULES, 50mA DRIVE CAPACITY (400 Hz BW)  
MODEL  
INPUT RANGE  
OUTPUT RANGE*  
MODEL INPUT RANGE  
OUTPUT RANGE  
OM5-WMV-10A-C 10mV  
OM5-WMV-50A-C 50mV  
OM5-WMV-100A-C 100mV  
OM5-WMV-10B-C 10mV  
OM5-WMV-50B-C 50mV  
OM5-WMV-100B-C 100mV  
5V  
OM5-AV-1-C  
OM5-AV-2-C  
OM5-AV-3-C  
OM5-AV-4-C  
OM5-AV-5-C  
OM5-AV-6-C  
OM5-AV-7-C  
0 to +5V  
5V  
5V  
5
5V  
5V  
5V  
0 to +5V  
10V  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +10V  
10V  
10V  
5V  
10V  
0 to +10V  
10V  
OM5-WV-1A-C  
OM5-WV-5A-C  
OM5-WV-10A-C  
OM5-WV-1B-C  
OM5-WV-5B-C  
OM5-WV-10B-C  
OM5-WV-20A-C  
OM5-WV-20B-C  
OM5-WV-40A-C  
OM5-WV-40B-C  
1V  
5V  
5V  
5V  
ACCESSORIES  
MODEL  
10V  
1V  
5V  
10V  
20V  
20V  
40V  
40V  
5V  
DESCRIPTION  
0 to +5V  
0 to +5V  
0 to +5V  
5V  
OM5-BP-16-C  
OM5-BP-16-DIN-C  
OM5-BP-16-MUX-C  
Non-multiplexed, 16 channel backpanel  
OM5-BP-16-C with DIN rail mounting option  
Multiplexed, 16 channel backpanel  
OM5-BP-16-MUX-DIN-C OM5-BP-16-MUX-C with DIN rail mounting option  
0 to +5V  
5V  
0 to +5V  
OM5-BP-8-C  
OM5-BP-8-DIN-C  
OM5-BP-8-MUX-C  
Non-multiplexed, 8 channel backpanel  
OM5-BP-8-C with DIN rail mounting option  
Multiplexed, 8 channel backpanel  
2-WIRE TRANSMITTER INTERFACE MODULES (100Hz BW)  
OM5-BP-8-MUX-DIN-C OM5-BP-8-MUX-C with DIN rail mounting option  
MODEL  
INPUT RANGE OUTPUT RANGE  
OM5-BP-SKT-C  
OM5-BP-2-C  
Single channel backpanel, DIN rail mount  
Dual channel backpanel, DIN rail mount  
Base element without snap foot  
Base element with snap foot  
System interface cable for analog backpanels  
xx = length in meters  
Daisy chain cable for OM5-BP-16-MUX-C  
Ribbon cable to screw interface board  
Package of 10 jumpers  
OM5-TX-1-C  
OM5-TX-2-C  
4 to 20mA  
4 to 20mA  
+1 to +5V  
+2 to +10V  
OM7-DIN-WSF  
OM7-DIN-SF  
GENERAL PURPOSE INPUT MODULES, DC EXCITATION  
MODEL MAXIMUM INPUT  
OMX-1315-xx-C  
OUTPUT*  
OMX-CAB-01-C  
OMX-1324-C  
OMX-1344-C  
OMX-955-C  
OM5-DT-1-C  
OM5-DT-2-C  
OM5-DT-3-C  
OM5-DT-4-C  
OM5-DT-5-C  
OM5-DT-6-C  
OM5-DT-7-C  
OM5-DT-8-C  
OM5-DT-9-C  
OM5-DT-10-C  
1V  
2V  
3V  
4V  
5V  
6V  
7V  
8V  
9V  
10V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
Power supply, 1A, 5VDC, 120VAC U.S.  
Power supply, 3A, 5VDC, 120VAC U.S.  
Power supply, 3A, 5VDC, 220VAC U.S.  
Precision 20resistor for OM5-II and OM5-TX  
Encapsulated cold junction circuit  
19 inch metal rack for mounting backpanels  
Side element  
OMX-977-C  
OMX-977-220-C  
OMX-1362-C  
OMX-CJC-C  
OMX-1363-C  
OM7-DIN-SE  
OM7-DIN-CP  
Connection pins  
FREQUENCY INPUT MODULES  
MODEL INPUT RANGE  
OUTPUT RANGE*  
OM5-IFI-500-C 0 to 500Hz  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
0 to +5V  
*Note:  
OM5-IFI-1K-C  
OM5-IFI-3K-C  
OM5-IFI-5K-C  
0 to 1kHz  
0 to 3kHz  
0 to 5kHz  
Any module not shown with a 10V output can be specified with 10V output.  
Consult factory for minimum quantity and pricing details and module  
specifications.  
OM5-IFI-10K-C 0 to 10kHz  
OM5-IFI-25K-C 0 to 25kHz  
OM5-IFI-50K-C 0 to 50kHz  
OM5-IFI-100K-C 0 to 100kHz  
**THERMOCOUPLE ALLOY COMBINATIONS  
TYPE  
MATERIAL  
J
Iron vs. Copper-Nickel  
Nickel-Chromium vs. Nickel-Aluminum  
Copper vs. Copper-Nickel  
Nickel-Chromium vs. Copper-Nickel  
Platinum-13% Rhodium vs. Platinum  
Platinum-10% Rhodium vs. Platinum  
Platinum-30% Rhodium vs.Platinum-6%Rhodium  
Tungsten-5% Rhenium vs. Tungsten-26% Rhenium  
Nickel-14.2% Chromium-1.4% Silicon vs. Nickel-4.4%  
Silicon-0.1% Magnesium  
LINEARIZED THERMOCOUPLE INPUT MODULES (0 to +5V OUTPUT*,  
4Hz BW)  
K
T
E
R
S
B
C
N
MODEL  
TYPE**  
INPUT RANGE  
OM5-LTC-J1-C  
OM5-LTC-J2-C  
OM5-LTC-J3-C  
OM5-LTC-J4-C  
OM5-LTC-K1-C  
OM5-LTC-K2-C  
OM5-LTC-K3-C  
OM5-LTC-K4-C  
OM5-LTC-T1-C  
OM5-LTC-T2-C  
OM5-LTC-E-C  
OM5-LTC-R-C  
OM5-LTC-S-C  
OM5-LTC-B-C  
J
J
0°C to +760°C (+32°F to +1400°F)  
–100°C to +300°C (–148°F to +572°F)  
0°C to +500°C (+32°F to +932°F)  
J
J
–100°C to +760°C (–148°F to +1400°F)  
0°C to +1000°C (+32°F to +1832°F)  
0°C to +500°C (+32°F to +932°F)  
K
K
K
K
T
T
E
R
S
B
–100°C to +1350°C (–148°F to +2462°F)  
0°C to +1200°C (+32°F to +2192°F)  
–100°C to +400°C (–148°F to +752°F)  
0°C to +200°C (+32°F to +392°F)  
***RTD ALPHA COEFFICIENTS  
TYPE  
ALPHA COEFFICIENT  
100Pt  
120Ni  
10Cu  
0.00385  
0.00672  
0.004274  
0°C to +1000°C (+32°F to +1832°F)  
+500°C to +1750°C (+932°F to +3182°F)  
+500°C to +1750°C (+932°F to +3182°F)  
+500°C to +1800°C (+932°F to +3272°F)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IMV/IV  
Analog Voltage Input Modules, Narrow Bandwidth  
FEATURES  
ACCEPTS MILLIVOLT AND VOLTAGE LEVEL SIGNALS  
DESCRIPTION  
Each OM5-IMV and OM5-IV voltage input module provides a single  
channel of analog input which is filtered, isolated, amplified, and converted  
to a high level analog voltage output (Figure 1). This voltage output is  
logic-switch controlled, allowing these modules to share a common analog  
bus without the requirement of external multiplexers.  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
The OM5 modules are designed with a completely isolated computer side  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
95dB NMR AT 60Hz, 90dB at 50Hz  
0.05% ACCURACY  
0.02% LINEARITY  
1µV/°C DRIFT  
Signal filtering is accomplished with a six-pole filter which provides 95dB  
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter  
are on the field side of the isolation barrier, and the other four are on the  
computer side.  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
After the initial field-side filtering, the input signal is chopped by a  
proprietary chopper circuit. Isolation is provided by transformer coupling,  
again using a proprietary technique to suppress transmission of common  
mode spikes or surges. The module is powered from +5VDC, 5%.  
MIX AND MATCH OM5 TYPES ON BACKPANELS  
A special input circuit on the OM5-IMV and OM5-IV modules provides  
protection against accidental connection of power-line voltages up to  
240VAC.  
4
NC  
+EXC  
+In  
LPF  
Isochopper™  
20  
4
3
2
1
Amplifier  
LPF  
VOUT  
Surge  
Suppression  
and  
6
Pat Pending  
VIN  
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
+V  
–V  
–In  
–EXC  
NC  
Isolated  
Computer-Side  
Power  
Backpanel  
Term Block  
1
NC  
NC  
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-IMV/IV Block Diagram.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Module  
OM5-IMV  
OM5-IV  
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
10mV to 100mV  
0.5nA  
1V to 40V  
0.05nA  
50MΩ  
40kΩ  
40kΩ  
650k(minimum)  
650k(minimum)  
650k(minimum)  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
*
*
Transient  
CMV, Input to Output  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
*
*
*
*
95dB at 60Hz, 90dB at 50Hz  
Accuracy(1)  
Nonlinearity  
Stability  
0.05% Span 10µV RTI(2) 0.05%(VZ(3)  
)
0.05% Span 0.2mV RTI(2) 0.05%(VZ(3)  
*
)
0.02% Span  
Input Offset  
Output Offset  
Gain  
1µV/°C  
20µV/°C  
25ppm/°C  
20µV/°C  
*
50ppm/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% Span  
0.2µVrms  
200µVrms  
4Hz  
2µVrms  
*
*
*
0.2s  
Output Range  
5V, 0V to +5V  
50Ω  
*
*
*
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
Output Current Limit  
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
)
*
*
8mA  
Output Enable Control  
Max Logic “0”  
+0.8V  
+2.4V  
+36V  
0.5µA  
*
*
*
*
Min Logic “1”  
Max Logic “1”  
Input Current, “0”, “1”  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
*
*
2µV/% RTI(2)  
200µV/% RTI(2)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
*
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
*
*
*
*
*
0 to 95% Noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
MODEL  
INPUT RANGE  
OUTPUT RANGE  
OM5-IMV-10A-C  
OM5-IMV-50A-C  
OM5-IMV-100A-C  
OM5-IMV-10B-C  
OM5-IMV-50B-C  
OM5-IMV-100B-C  
–10mV to +10mV  
–50mV to +50mV  
–100mV to +100mV  
–10mV to +10mV  
–50mV to +50mV  
–100mV to +100mV  
–5V to +5V  
–5V to +5V  
–5V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
* Same specification as OM5-IMV.  
NOTES: (1) Includes nonlinearity,  
hysteresis and repeatability.  
(2) RTI = Referenced to input.  
(3) VZ is the input voltage that results  
in 0V output.  
ORDERING  
INFORMATION  
OM5-IV-1A-C  
OM5-IV-5A-C  
OM5-IV-10A-C  
OM5-IV-1B-C  
OM5-IV-5B-C  
OM5-IV-10B-C  
OM5-IV-20A-C  
OM5-IV-20B-C  
OM5-IV-40A-C  
OM5-IV-40B-C  
–1V to +1V  
–5V to +5V  
–10V to +10V  
–1V to +1V  
–5V to +5V  
–5V to +5V  
–5V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
–5V to +5V  
0V to +5V  
–5V to +5V  
0V to +5V  
–5V to +5V  
–10V to +10V  
–20V to +20V  
–20V to +20V  
–40V to +40V  
–40V to +40V  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-II  
Analog Current Input Modules  
FEATURES  
DESCRIPTION  
ACCEPTS MILLIAMP LEVEL SIGNALS  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
Each OM5-II current input module provides a single channel of analog input  
which is filtered, isolated, amplified, and converted to a high level analog  
voltage output (Figure 1). This voltage output is logic switch controlled,  
which allows these modules to share a common analog bus without the  
requirement of external multiplexers.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
The OM5-II modules are designed with a completely isolated computer side  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply connect-  
ing pin 22, the Read-Enable pin to I/O Common, pin 19.  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
95dB NMR AT 60Hz, 90dB AT 50Hz  
0.05% ACCURACY  
A precision 20current conversion resistor is supplied with the OM5-II  
module. Sockets are provided on the OM5-BP backpanels to allow installa-  
tion of this resistor. Extra resistors are available under part number OMX-  
1362-C.  
0.02% LINEARITY  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANELS  
Signal filtering is accomplished with a six-pole filter which provides 95dB of  
normal-mode rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are  
onthefieldsideoftheisolationbarrier, andtheotherfourareonthecomputer  
side.  
Aftertheinitialfield-sidefiltering, theinputsignalischoppedbyaproprietary  
chopper circuit. Isolation is provided by transformer coupling, again using  
aproprietarytechniquetosuppresstransmissionofcommonmodespikesor  
surges. The module is powered from +5VDC, 5%.  
A special input circuit on the OM5-II modules provides protection against  
accidental connection of power-line voltages up to 240VAC.  
4
NC  
+EXC  
+In  
LPF  
Isochopper™  
20  
4
3
2
1
LPF  
VOUT  
Amplifier  
Surge  
Suppression  
and  
6
Pat Pending  
IIN  
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
+V  
–V  
–In  
–EXC  
NC  
Isolated  
Computer-Side  
Power  
20  
0.1% plug-in  
Backpanel  
Term Block  
1
NC  
2
NC  
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-II Block Diagram.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA = +25°C and +5V power.  
OM5-II  
Module  
Input Range  
Input Resistor  
Value  
0mA to 20mA or 4mA to 20mA  
20.00Ω  
0.1%  
Accuracy  
Stability  
10ppm/°C  
Input Protection  
Continuous  
Transient  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
CMV, Input to Output  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
95dB at 60Hz, 90dB at 50Hz  
(2)  
Accuracy(1)  
Nonlinearity  
0.05% span 0.05% (IZ  
0.02% Span  
)
Stability  
Input Offset  
Output Offset  
Gain  
Noise  
50nA/°C  
20µV/°C  
25ppm/°C  
Input, 0.1Hz to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% Span  
10nArms  
200µVrms  
4Hz  
0.2s  
Output Range  
0 to +5V  
50Ω  
Output Resistance  
Output Protection  
Output Selection Time  
Continuous Short to Gnd  
6µs at Cload = 0 to 2000pF  
(to 1mV of V  
)
Output Current LOimUTit  
+8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
Max Logic “1”  
Input Current, “0,1”  
+0.8V  
+2.4V  
+36V  
0.5µA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
20µV/% RTI(3)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60"  
(58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
-40°C to +85°C  
-40°C to +85°C  
0 to 95% Noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
NOTE: (1) Includes nonlinearity, hysteresis and repeatability. (2) IZ is the input current that  
results in 0V output. (3) RTI = Referenced to input.  
ORDERING INFORMATION  
MODEL  
INPUT RANGE  
OUTPUT RANGE  
BANDWIDTH  
OM5-II-4/20-C  
OM5-II-0/20-C  
4mA to 20mA  
0mA to 20mA  
0V to +5V  
0V to +5V  
4Hz  
4Hz  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IAC  
Isolated True RMS Input Modules  
FEATURES  
DESCRIPTION  
INTERFACES RMS VOLTAGE (0 – 300V) OR RMS CURRENT (0 – 5A)  
EachOM5-IACTrueRMSinputmoduleprovidesasinglechannelofACinput  
which is converted to its True RMS dc value, filtered, isolated, amplified, and  
converted to a standard process voltage or current output (Figure 1).  
DESIGNED FOR STANDARD OPERATION WITH FREQUENCIES OF  
45HZ TO 1000HZ (EXTENDED RANGE TO 20Khz)  
The OM5-IAC modules are designed with a completely isolated computer  
side circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired,theoutputswitchcanbeturnedoncontinuouslybysimplyconnecting  
pin 22, the Read-Enable pin to I/O Common, pin 19.  
COMPATIBLE WITH STANDARD CURRENT AND POTENTIAL  
TRANSFORMERS  
INDUSTRY STANDARD 0-5V OUTPUT  
0.25% FACTORY CALIBRATED ACCURACY (ACCURACY CLASS  
0.2)  
The field voltage or current input signal is processed through a pre-amplifier  
and RMS converter on the field side of the isolation barrier. The converted dc  
signalisthenchoppedbyaproprietarychoppercircuitandtransferredacross  
the transformer isolation barrier, suppressing transmission of common  
modespikesandsurges. Thecomputersidecircuitryreconstructs, filtersand  
converts the signal to a 0-5VDC output. Modules are powered from +5VDC,  
5%.  
1500 VRMS CONTINUOUS TRANSFORMER BASED ISOLATION  
INPUT OVERLOAD PROTECTED TO 480V MAX (PEAK AC & DC) OR  
10A RMS CONTINUOUS  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
4
Pre-Amp,  
Conversion  
+EXC  
Isochopper™  
20  
4
LPF  
VOUT or IOUT  
Amplifier  
Surge  
Suppression  
and  
AC Source +In  
6
Pat Pending  
3
2
1
IIN  
*
19  
22  
5
3
I/O Common  
RD EN\  
Protection  
+V  
–V  
–In  
–EXC  
Isolated  
Computer-Side  
Power  
Backpanel  
Term Block  
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
* Current Input Models Only  
FIGURE 1. OM5-IAC Block Diagram.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA = +25°C and +5V power.  
OM5-IAC  
Module  
Input  
Signal Range  
Standard Frequency Range  
Extended Frequency Range  
Impedance  
100mV to 10V rms, 0 to 5A rms  
45Hz to 1000Hz  
1kHz to 20kHz  
1 M1% shunted by 100pF (-01 thru -05),  
0.051% (-06, -07)  
AC  
Coupling  
Protection(1)  
Continuous  
480V (Peak AC & DC)  
Transient  
ANSI/IEEE C37.90.1-1989  
Output  
Signal Range  
0-5V  
Current Limit  
Voltage Limit  
8mA  
18V  
Resistance  
Protection  
Ripple and Noise (100Khz)  
50Ω  
Continuous Short to Ground  
0.025% Span rms  
Accuracy(2)(3)  
Sinusoid  
50/60 Hz  
0.25% Span  
45Hz to 1kHz  
1kHz to 20kHz  
Non-Sinusoid  
0.25% Reading Additional Factor  
0.75% Reading Additional Factor  
Crest Factor = 1 to 2  
Crest Factor = 2 to 3  
Crest Factor = 3 to 4  
Crest Factor = 4 to 5  
Vs. Temperature  
0.05% Reading Additional Error  
0.15% Reading Additional Error  
0.30% Reading Additional Error  
0.40% Reading Additional Error  
100ppm/°C  
ORDERING INFORMATION  
MODEL  
INPUT* (rms)  
OUTPUT* (dc)  
Isolation (Common Mode)  
Input to Output, Input to Power  
Continuous  
Transient  
Output to Power  
Continuous  
OM5-IAC-100B-C  
OM5-IAC-1B-C  
OM5-IAC-10B-C  
0-100mV  
0-1V  
0-10V  
0-5V  
0-5V  
0-5V  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
50Vdc max  
100dB  
Rejection (50-60Hz Common Mode)  
Response Time (0 to 99%)  
<400ms  
* Modules can be ordered with other input/output ranges. Consult factory for  
ordering details and specifications.  
Output Enable Control  
Selection Time  
Voltage  
6.0µS @ CLOAD = 0 to 2000pF  
Max Logic “0”  
Min / Max Logic “1”  
Current, “0,1”  
+0.8V  
+2.4V / +36V  
0.5µA  
Loop Voltage  
Load Resistance (maximum)  
+7.5Vdc min, +26Vdc max  
(Loop Voltage - 14) / (Loop Current)  
Supply Voltage  
Current  
Sensitivity  
+5VDC 5%  
30mA  
200ppm/%  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
Immunity  
Dimensions  
-40˚ C to +85˚ C  
-40˚ C to +85˚ C  
0 to 90% noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
NOTE:  
(1) Module rating only. Backpanel connector rating may differ — use the lowest of the two in  
accordance with required safety requirements.  
(2) At standard 60Hz factory calibration. Consult factory for calibration at other frequencies.  
(3) For 10-100% rated span. Add an additional 0.25% error for 0-10% Span measurements.  
Accuracy includes nonlinearity, hysteresis and repeatability but not source or external shunt  
inaccuracy (if used).  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IP/IC/IN  
Linearized 2- or 3-Wire RTD Input Modules  
FEATURES  
INTERFACES TO 100PLATINUM, 10COPPER,  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
OR 120NICKEL RTDs  
LINEARIZES RTD SIGNAL  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
RTD excitation is provided from the module by two matched current  
sources. When using a three-wire RTD, this method allows an equal current  
to flow in each RTD lead, which cancels the effects of lead resistances. The  
excitation currents are very small (0.25mA for 100Pt and 120Ni, and  
1.0mA for 10Cu) which minimizes self-heating of the RTD.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
Signal filtering is accomplished with a six-pole filter which provides 95dB  
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter  
are on the field side of the isolation barrier, and the other four are on the  
computer side. After the initial field-side filtering, the input signal is  
chopped by a proprietary chopper circuit. Isolation is provided by trans-  
former coupling, again using a proprietary technique to suppress transmis-  
sion of common mode spikes or surges. The module is powered from  
+5VDC, 5%.  
95dB NMR AT 60Hz, 90dB AT 50Hz  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
DESCRIPTION  
Each OM5 RTD input module provides a single channel of RTD input which  
is filtered, isolated, amplified, linearized, and converted to a high level  
analog voltage output (Figure 1). This voltage output is logic switch  
controlled, which allows these modules to share a common analog bus  
without the requirement of external multiplexers.  
A special input circuit on the OM5 modules provides protection against  
accidental connection of power-line voltages up to 240VAC.  
The OM5 modules are designed with a completely isolated computer side  
3 and 4 Wire(1)  
2 Wire  
20  
VOUT  
Linearizer  
LPF  
+EXC  
4
6
LPF  
Isochopper™  
Amplifier  
Pat Pending  
4
3
2
1
19  
22  
I/O Common  
RD EN\  
Surge  
Suppression  
and  
+In  
RZ  
RTD  
5
3
Protection  
+V  
–V  
–In  
NC  
Isolated  
–EXC  
Computer-Side  
Power  
4 Wire(1)  
Backpanel  
Term Block  
1
–V  
–V  
NC  
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
NOTE: (1) 4-wire sensors may be  
used with this module. However,  
for true 4-wire measurement,  
use OM5-IP4/IC4/IN4.  
Power Common  
FIGURE 1. OM5-IP/IC/IN Block Diagram.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA= +25°C and +5V Power.  
Module  
OM5-IP/IC/IN  
Input Range Limits  
–200°C to +850°C (100Pt)  
–80°C to 320°C (120Ni)  
–100°C to 260°C (10Cu)  
Input Resistance  
Normal  
Power Off  
50MΩ  
40kΩ  
40kΩ  
Overload  
Input Protection  
Continuous  
Transient  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
Sensor Excitation Current  
100Pt, 120Ni  
10Cu  
0.25mA  
1.0mA  
Lead Resistance Effect  
100Pt, 120Ni  
10Cu  
(1)  
0.02°C/Ω  
0.2°C/Ω  
(1)  
CMV, Input to Output  
Continuous  
Transient  
CMR (50 or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
95dB at 60Hz, 90dB at 50Hz  
Accuracy  
Conformity Error  
Stability  
See Ordering Information  
0.05% Span  
Input Offset  
Output Offset  
Gain  
0.02°C/°C  
20µV/°C  
50ppm of reading/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% Span  
0.2µVrms  
200µVrms  
4Hz  
0.2s  
Output Range  
0V to +5V  
50Ω  
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
ORDERING INFORMATION  
MODEL  
INPUT RANGE  
OUTPUT RANGE ACCURACY†  
(to 1mV of VOUT  
)
100Pt,  
Output Current Limit  
+8mA  
α = 0.00385  
OM5-IP-N100-C  
–100°C to +100°C  
(–148°F to +212°F)  
0°C to +100°C  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0.32°C  
0.13°C  
0.26°C  
0.78°C  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
Max Logic “1”  
Input Current, “0,1”  
+0.8V  
+2.4V  
+36V  
0.5µA  
OM5-IP-100-C  
OM5-IP-200-C  
OM5-IP-600-C  
(+32°F to 212°F)  
0°C to +200°C  
(+32°F to 392°F)  
0°C to +600°C  
(+32°F to 1112°F)  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
100Pt, 120Ni  
10Cu  
+5VDC 5%  
30mA  
10Cu,  
α = 0.004274  
0.2°C/V  
0.5°C/V  
OM5-IC-120-01-C 0°C to +120°C (10at 0°C)  
(+32°F to +248°F)  
0V to +5V  
0V to +5V  
0.23°C  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" ( 58mm x 57mm x 15mm )  
OM5-IC-120-02-C 0°C to +120°C (10at 25°C)  
(+32°F to +248°F)  
0.23°C  
Environmental  
Operating Temperature Range  
Storage Temperature Range  
Relative Humidity  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% noncondensing  
EN50081-1, ISM Group 1,  
Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1,  
Class A (ESD, RF, EFT)  
Emissions  
120Ni,  
α = 0.00672  
OM5-IN-300-C  
Immunity  
0°C to +300°C  
(+32°F to +572°F)  
0V to +5V  
0.40°C  
Includes conformity, hysteresis and repeatability.  
NOTES: (1) "" refers to the resistance in one lead.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IP4/IC4/IN4  
Linearized 4-Wire RTD Input Modules  
Each OM5 4-wire RTD input module provides a single channel of RTD input  
FEATURES  
which is filtered, isolated, amplified, linearized, and converted to a high  
level analog voltage output. This voltage output is logic switch controlled,  
which allows these modules to share a common analog bus without the  
requirement of external multiplexers.  
INTERFACES TO 100PLATINUM, 10COPPER,  
OR 120NICKEL RTDs  
TRUE 4-WIRE INPUT  
The OM5 modules are designed with a completely isolated computer side  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
LINEARIZES RTD SIGNAL  
HIGH LEVEL VOLTAGE OUTPUT  
1500Vrms TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
RTD excitation is provided from the module by a precision current source.  
The excitation current is available on two leads which are separate from the  
two input signal measuring leads. The excitation current does not flow in  
the input signal leads, which allows RTD measurement to be totally  
independent of lead resistance. The excitation current is very small (0.25mA  
for 100 Pt and 120 Ni and 1.0 mA for 10Cu) which minimizes self-  
heating of the RTD.  
95dB NMR AT 60HZ, 90dB AT 50HZ  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
Signal filtering is accomplished with a six-pole filter which provides 95dB  
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter  
are on the field side of the isolation barrier, and the other four are on the  
computer side. After the initial field-side filtering, the input signal is  
chopped by a proprietary chopper circuit. Isolation is provided by trans-  
former coupling, again using a proprietary technique to suppress transmis-  
sion of common mode spikes or surges. The module is powered from  
+5VDC, 5%.  
DESCRIPTION  
In RTD temperature measurement applications requiring a very high level  
of accuracy, the OM5 4-Wire RTD input module offers a significant  
advantage over 3-wire measurement techniques (Figure 1). The OM5  
measures only the voltage dropped across the RTD and almost completely  
ignores the resistance or length of the RTD lead wires. The OM5  
3-Wire RTD module provides lead resistance compensation, but requires  
equal lead resistances, while the 4-wire modules do not require matched  
lead resistances.  
A special input circuit provides protection against accidental connection of  
power-line voltages up to 240VAC.  
20  
VOUT  
Linearizer  
LPF  
+EXC  
+In  
4
6
LPF  
Isochopper™  
Amplifier  
Pat Pending  
4
3
2
1
19  
22  
I/O Common  
RD EN\  
Surge  
Suppression  
and  
RTD  
5
3
Protection  
+V  
–V  
–In  
4 Wire  
RTD  
Isolated  
Computer-Side  
Power  
–EXC  
Backpanel  
Term Block  
1
–V  
NC  
2
NC  
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-IP4/IC4/IN4 Block Diagram.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA = +25°C and +5V Power.  
Module  
OM5-IP4/IC4/IN4  
Input Range Limits  
–200°C to +850°C (100Pt)  
–80°C to +320°C (120Ni)  
–100°C to +260°C (10Cu)  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
50MΩ  
40kΩ  
40kΩ  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
Sensor Excitation Current  
100Pt, 120Ni  
10Cu  
0.25mA  
1.0mA  
Lead Resistance Effect  
100Pt, 120Ni  
10Cu  
(1)  
0.0005 °C/Ω  
(1)  
0.005 °C/Ω  
CMV, Input to Output  
Continuous  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
Transient  
CMR (50Hz or 60Hz)  
NMR  
95dB at 60Hz, 90dB at 50Hz  
Accuracy  
Conformity Error  
Stability  
See Ordering Information  
0.05% Span  
Input Offset  
Output Offset  
Gain  
0.02°C/°C  
20µV/°C  
50ppm of reading/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% span  
0.2µVrms  
200µVrms  
4Hz  
0.2s  
Output Range  
0V to +5V  
50Ω  
Continuous short to ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
+0.8V  
+2.4V  
+36V  
0.5µA  
Min Logic “1”  
Max Logic “1”  
Input Current, “0,1”  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
100Pt, 120Ni  
10Cu  
+5VDC 5%  
30mA  
0.2°C/V  
0.5°C/V  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
NOTES: (1) ” refers to the resistance  
in one lead.  
Immunity  
ORDERING  
INFORMATION  
MODEL  
INPUT RANGE  
OUTPUT RANGE  
0V to +5V  
ACCURACY†  
100 Pt, α = 0.00385  
OM5-IP4-N100-C  
OM5-IP4-100-C  
OM5-IP4-200-C  
OM5-IP4-600-C  
–100°C to +100°C (–148°F to +212°F)  
0°C to +100°C (+32°F to 212°F)  
0°C to +200°C (+32°F to 392°F)  
0°C to +600°C (+32°F to 1112°F)  
0.32°C  
0.13°C  
0.26°C  
0.78°C  
0V to +5V  
0V to +5V  
0V to +5V  
10 Cu, α = 0.004274  
OM5-IC4-120-01-C  
OM5-IC4-120-02-C  
Includes conformity,  
hysteresis and repeatability.  
0°C to +120°C (10at 0°C) (+32°F to +248°F)  
0°C to +120°C (10at 25°C) (+32°F to +248°F)  
0V to +5V  
0V to +5V  
0.23°C  
0.23°C  
120 Ni, α = 0.00672  
OM5-IN4-300-C  
0°C to +300°C (+32°F to +572°F)  
0V to +5V  
0.40°C  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-PT  
Potentiometer Input Modules  
FEATURES  
DESCRIPTION  
INTERFACES TO POTENTIOMETERS UP TO 10,000 OHMS  
Each OM5-PT Potentiometer input module provides a single channel of  
potentiometer input which is filtered, isolated, amplified, and converted to a  
high level analog voltage output (Figure 1). This voltage output is logic  
switch controlled, which allows these modules to share a common analog  
bus without the requirement of external multiplexers.  
HIGH LEVEL VOLTAGE OUTPUTS  
1500 VOLT TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
The OM5 modules are designed with a completely isolated computer side  
circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
95dB NMR AT 60HZ, 90dB AT 50HZ  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
Excitation for the potentiometer is provided from the module by two matched  
current sources. When using a three-wire potentiometer, this method allows  
cancellationoftheeffectsofleadresistances. Theexcitationcurrentsarevery  
small (less than 1.0mA) which minimizes self-heating of the potentiometer.  
Signal filtering is accomplished with a six-pole filter which provides 95dB of  
normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are  
on the field side of the isolation barrier, and the other four are in the output  
stage. After the initial field-side filtering, the input signal is chopped by a  
proprietary chopper circuit. Isolation is provided by transformer coupling,  
again using a proprietary technique to suppress transmission of common  
mode spikes or surges. The module is powered from +5VDC, 5%.  
A special input circuit provides protection against accidental connection of  
power-line voltages up to 240VAC.  
3-Wire  
Potentiometer  
+EXC  
+In  
4
6
LPF  
Isochopper™  
20  
4
3
2
4
3
2
1
Amplifier  
LPF  
VOUT  
Surge  
Suppression  
and  
Pat Pending  
19  
22  
5
3
Protection  
I/O Common  
RD EN\  
+V  
–V  
–In  
2-Wire  
Slidewire  
NC  
Isolated  
–EXC  
Computer-Side  
Power  
Backpanel  
Term Block  
1
–V  
–V  
NC  
2
17  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
16  
Power Common  
FIGURE 1. OM5-PT Block Diagram.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at Ta = +25˚C and +5V Power  
Module  
OM5-PT  
Input Range  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
0 to 10KΩ  
50MΩ  
40KΩ  
40KΩ  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
Sensor Excitation Current  
0.25mA; 100, 500, 1Ksensor  
0.10mA; 10Ksensor  
0.01/; 100, 500, 1Ksensor  
0.02/; 10Ksensor  
Lead Resistance Effect  
CMV, Input to Output  
Continuous  
Transient  
CMR (50 or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
95dB @ 60Hz, 90dB @ 50Hz  
Accuracy(2)  
Stability  
0.08% Span  
Input Offset  
0.004/°C; 100, 500, 1Ksensor  
0.010/°C; 10Ksensor  
Output Offset  
Gain  
20µV/°C  
50ppm of reading/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100KHz  
Bandwidth, -3dB  
Response Time, 90% span  
0.2µVrms  
200µVrms  
4Hz  
0.2s  
Output Range  
0 to +5V  
50Ω  
Continuous short to ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
+0.8V  
+2.4V  
+36V  
0.5µA  
Min Logic “1”  
Max Logic “1”  
Input Current, “0,1”  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
2µV/% RTI(1)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
-40°C to +85°C  
-40°C to +85°C  
0 to 95% noncondensing  
EN50081-1, ISM Group 1,  
Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1,  
Class A (ESD, RF, EFT)  
Immunity  
NOTES: (1) Referenced to input. (2) Includes nonlinearity, hysteresis and repeatability.  
ORDERING INFORMATION  
MODEL  
INPUT RANGE  
OUTPUT RANGE  
OM5-PT-100-C  
OM5-PT-500-C  
OM5-PT-1K-C  
OM5-PT-10K-C  
0 to 100Ω  
0 to 500Ω  
0 to 1KΩ  
0 to 10KΩ  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-ITC  
Thermocouple Input Modules  
The OM5-ITC modules are designed with a completely isolated computer  
FEATURES  
INTERFACES TO TYPES J, K, T, E, R, S, C, N AND B  
side circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
THERMOCOUPLES  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
The OM5-ITC can interface to nine industry standard thermocouple types:  
J, K, T, E, R, S, C, N, and B. Its corresponding output signal operates over  
a 0V to +5V range. Each module is cold-junction compensated to correct  
for parasitic thermocouples formed by the thermocouple wire and screw  
terminals on the mounting backpanel. Upscale open thermocouple detect  
is provided by an internal pull-up resistor. Downscale indication can be  
implemented by installing an external 47Mresistor, 20% tolerance,  
between screw terminals 1 and 3 on the OM5-BP backpanels.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
160dB CMR  
95dB NMR AT 60Hz, 90dB at 50Hz  
0.05% ACCURACY  
Signal filtering is accomplished with a six-pole filter which provides 95dB  
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter  
are on the field side of the isolation barrier, and the other four are on the  
computer side.  
0.02% LINEARITY  
1µV/°C DRIFT  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
After the initial field-side filtering, the input signal is chopped by a  
proprietary chopper circuit. Isolation is provided by transformer coupling,  
again using a proprietary technique to suppress transmission of common  
mode spikes or surges. The module is powered from +5VDC, 5%.  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
DESCRIPTION  
A special input circuit provides protection against accidental connection of  
power-line voltages up to 240VAC.  
Each OM5-ITC Thermocouple input module provides a single channel of  
thermocouple input which is filtered, isolated, amplified, and converted to  
a high level analog voltage output (Figure 1). This voltage output is logic-  
switch controlled, allowing these modules to share a common analog bus  
without the requirement of external multiplexers.  
+2.5V  
100M  
4
NC  
+EXC  
+In  
LPF  
Isochopper™  
20  
4
3
2
1
LPF  
Amplifier  
VOUT  
Surge  
Suppression  
and  
6
Pat Pending  
Thermocouple  
19  
22  
5
3
Protection  
I/O Common  
RD EN\  
+V  
–V  
–In  
–EXC  
Isolated  
Precision  
Computer-Side  
Power  
Reference  
Backpanel  
Term Block  
CJC  
1
2
17  
16  
+V  
–V  
+5V  
Temp  
Sensor  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-ITC Block Diagram.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS Typical at TA = +25°C and +5V power.  
Module  
OM5-ITC  
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Input Protection  
Continuous  
Transient  
-0.1V to +0.5V  
-25nA  
50MΩ  
40kΩ  
40kΩ  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
CMV, Input to Output  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
160dB  
95dB at 60Hz, 90dB at 50Hz  
Accuracy  
Nonlinearity  
Stability  
Input Offset  
Output Offset  
Gain  
See Ordering Information  
0.02% Span  
1µV/°C(3)  
20µV/°C  
25ppm/°C  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
Bandwidth, –3dB  
Response Time, 90% Span  
0.2µVrms  
200µVrms  
4Hz  
0.2s  
Output Range  
0V to +5V  
50Ω  
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
)
Output Current Limit  
+8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
+0.8V  
+2.4V  
+36V  
Max Logic “1”  
Input Current, “0”, “1”  
Open Input Response  
Open Input Detection Time  
Cold Junction Compensation  
Accuracy, 25°C  
Accuracy, +5°C to +45°C  
Accuracy, –40°C to +85°C  
0.5µA  
Upscale  
10s  
0.25°C  
0.5°C  
1.25°C  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
30mA  
2µV/% RTI(2)  
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
Environmental  
NOTES: (1) Includes nonlinearity, hysteresis  
and repeatability. Does not include CJC  
accuracy. (2) RTI = Referenced to input.  
(3)This is equivalent to °C as follows: Type J  
0.020 °C/°C, Types K, T 0.025°C/°C,  
Type E 0.016°C/°C, Types R, S 0.168°C/°C.  
Type N 0.037°C/°C, Type C, 0.072°C/°C.  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% Noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
ORDERING  
INFORMATION  
MODEL  
TYPE  
INPUT RANGE  
OUTPUT RANGE  
ACCURACY(1)  
OM5-ITC-J-C  
OM5-ITC-K-C  
OM5-ITC-T-C  
OM5-ITC-E-C  
OM5-ITC-R-C  
OM5-ITC-S-C  
OM5-ITC-B-C  
OM5-ITC-C1-C  
OM5-ITC-N1-C  
Type J  
Type K  
Type T  
Type E  
Type R  
Type S  
Type B  
Type C  
Type N  
–100°C to +760°C (–148°F to +1400°F)  
–100°C to +1350°C (–148°F to +2462°F)  
–100°C to +400°C (–148°F to +752°F)  
0°C to +900°C (+32°F to +1652°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1800°C (+32°F to +3272°F)  
+350°C to +1300°C (+662°F to +2372°F)  
–100°C to +1300°C (–148°F to +2372°F)  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
0V to +5V  
OV to +5V  
0V to +5V  
0.07%  
0.07%  
0.09%  
0.07%  
0.10%  
0.10%  
0.12%  
0.11%  
0.70%  
0.61˚C  
0.97˚C  
0.46˚C  
0.59˚C  
1.72˚C  
1.82˚C  
2.21˚C  
1.01˚C  
0.98˚C  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-WBS  
Strain Gage Input Modules, Wide Bandwidth  
FEATURES  
The OM5-WBS modules are designed with a completely isolated computer  
side circuit which can be floated to 50V from Power Common, pin 16. This  
complete isolation means that no connection is required between I/O  
Common and Power Common for proper operation of the output switch. If  
desired, the output switch can be turned on continuously by simply  
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.  
INTERFACES TO 100THRU 10k, FULL-BRIDGE, HALF-BRIDGE,  
OR QUARTER-BRIDGE STRAIN GAGES  
HIGH LEVEL VOLTAGE OUTPUTS  
1500Vrms TRANSFORMER ISOLATION  
The OM5-WBS can interface to full-bridge or half-bridge transducers with  
a nominal resistance of 100to 10k. A matched pair of bridge-  
completion resistors (to 1mV at +10V excitation) allows use of low cost  
half-bridge or quarter-bridge transducers (Figures 2, 3, 4). The 10kHz  
bandwidth allows measurement of high speed processes such as vibration  
analysis.  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
INPUT PROTECTED TO 240VAC CONTINUOUS  
FULLY ISOLATED EXCITATION SUPPLY  
100dB CMR  
Strain Gage excitation is provided from the module by a very stable 10V  
or 3.333V source. The excitation supply is fully isolated, allowing the  
amplifier inputs to operate over the full range of the excitation voltage. This  
feature offers significant flexibility in real world applications. Full scale  
sensitivities of 2mV/V, 3mV/V or 10mV/V are offered as standard. With 10V  
excitation, this results in 20mV, 30mV or 100mV full scale input range  
producing 5V full scale output.  
10kHz SIGNAL BANDWIDTH  
0.08% ACCURACY  
0.02% LINEARITY  
1µV/°C DRIFT  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
The input signal is processed through a pre-amplifier on the field side of  
the isolation barrier. This pre-amplifier has a gain-bandwidth product of  
5MHz and is bandwidth limited to 10kHz. After amplification, the input  
signal is chopped by a proprietary chopper circuit. Isolation is provided by  
transformer coupling, again using a proprietary technique to suppress  
transmission of common mode spikes or surges. The module is powered  
from +5VDC, 5%.  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
DESCRIPTION  
Each OM5-WBS Strain Gage input module provides a single channel of  
strain gage input which is filtered, isolated, amplified, and converted to a  
high level analog voltage output (Figure 1). This voltage output is logic  
switch controlled, which allows these modules to share a common analog  
bus without the requirement of external multiplexers.  
Special input circuits provide protection of the signal inputs and the  
isolated excitation supply up to 240VAC.  
+EXC  
+In  
4
LPF  
Isochopper™  
20  
Strain  
Gage  
4
3
2
1
LPF  
Amplifier  
VOUT  
Surge  
Suppression  
and  
6
5
3
Pat Pending  
19  
22  
Protection  
I/O Common  
RD EN\  
+V  
–V  
–In  
Isolated  
Excitation  
Source  
Isolated  
Computer-Side  
Power  
–EXC  
Backpanel  
Term Block  
1
2
17  
16  
+V  
–V  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power  
Common  
FIGURE 1. OM5-WBS Block Diagram.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 2. Full Bridge Connection.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Full Bridge  
OM5-WBS38-01-C, -WBS-1/-2/-4/-5-C  
Half Bridge  
OM5-WBS38-03-C,-WBS-3-C  
Module  
4
+EXC  
+In  
4
6
5
3
Input Range  
Input Bias Current  
Input Resistance  
Normal  
Power Off  
Overload  
Signal Input Protection  
Continuous  
Transient  
10mV to 100mV  
0.3nA  
*
*
V
EXC  
3
2
1
(1)  
R
(1)  
g
R
g
50MΩ  
40kΩ  
40kΩ  
*
*
*
–In  
(1)  
R
(1)  
g
R
g
240Vrms max  
ANSI/IEEE C37.90.1-1989  
*
*
–EXC  
OM5-WBS38-01-C  
OM5-WBS-1-C  
OM5-WBS-2-C  
OM5-WBS-4-C  
OM5-WBS-5-C  
Backpanel  
Terminal Block  
Excitation Output (-1/-2/-3/-5-C)  
Excitation Output (-4-C,-01/-03-C)  
Excitation Load Regulation  
Excitation Stability  
Half Bridge Voltage Level (-3-C)  
Half Bridge Voltage Level (-03-C)  
Isolated Excitation Protection  
Continuous  
+10V 3mV  
+3.333V 2mV  
5ppm/mA  
15ppm/°C  
NA  
*
*
*
*
+5V 1mV  
+1.667V 1mV  
NA  
FIGURE 3. Half Bridge Connection.  
240Vrms max  
ANSI/IEEE C37.90.1-1989  
*
*
Transient  
CMV, Input to Output  
Continuous  
Transient  
CMR (50 or 60Hz)  
NMR (–3dB at 10kHz)  
Accuracy(2)  
Nonlinearity  
Stability  
Input Offset  
Output Offset  
Gain  
4
+EXC  
+In  
4
6
5
3
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
100dB  
*
*
*
*
(1)  
R
V
R
g
EXC  
1
3
2
1
120dB per Decade above 10kHz  
0.08% Span 10µV RTI(3)  
*
*
–In  
0.02% Span  
NC  
(1)  
R
R
2
g
1µV/°C  
40µV/°C  
25ppm of Reading/°C  
*
*
*
OM5-WBS38-03-C  
OM5-WBS-3-C  
–EXC  
R
= R  
2
1
Backpanel  
Terminal Block  
Noise  
Input, 0.1 to 10Hz  
Output, 100kHz  
0.4µVrms  
10mVp-p  
2µVrms  
*
Bandwidth, –3dB  
Rise Time, 10 to 90% span  
Setting Time, to 0.1%  
10kHz  
35µs  
250µs  
*
*
*
FIGURE 4. Quarter Bridge Connection.  
Output Range  
5V  
50Ω  
*
*
*
*
Output Resistance  
Output Protection  
Output Selection Time  
(to 1mV of VOUT  
Output Current Limit  
4
Continuous Short to Ground  
6µs at Cload = 0 to 2000pF  
+EXC  
+In  
4
6
5
3
(1)  
V
R
R
EXC  
g
1
)
3
2
1
8mA  
Output Enable Control  
Max Logic “0”  
Min Logic “1”  
Max Logic “1”  
Input Current, “0,1”  
–In  
+0.8V  
+2.4V  
+36V  
0.5µA  
*
*
*
*
NC  
R
R
3
2
OM5-WBS38-03-C  
OM5-WBS-3-C  
–EXC  
R
= R  
2
1
Customer  
Supplied  
Backpanel  
Terminal Block  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
170mA Full Exc. Load, 70mA No Exc. Load  
2µV/% RTI(3)  
*
*
*
Mechanical Dimensions  
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)  
*
Environmental  
* Same as Full Bridge modules.  
NOTES: (1) Strain element. (2) Includes excitation error, nonlinearity,  
hysteresis and repeatability. (3) Referenced to input.  
Operating Temperature Range  
Storage Temperature Range  
Relative Humidity  
–40°C to +85°C  
–40°C to +85°C  
*
*
*
*
0 to 95% Noncondensing  
Emissions  
EN50081-1, ISM Group 1,  
Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
*
ORDERING  
INFORMATION  
MODEL (10kHz) INPUT BRIDGE TYPE  
INPUT RANGE  
EXCITATION  
OUTPUT RANGE  
OM5-WBS38-01-C  
OM5-WBS-1-C  
OM5-WBS38-03-C  
OM5-WBS-3-C  
OM5-WBS-2-C  
OM5-WBS-4-C  
OM5-WBS-5-C  
Full Bridge  
Full Bridge  
Half Bridge  
Half Bridge  
Full Bridge  
Full Bridge  
Full Bridge  
100to 10kΩ  
300to 10kΩ  
100to 10kΩ  
300to 10kΩ  
300to 10kΩ  
100to 10kΩ  
300to 10kΩ  
3.333V at 3mV/V Sensitivity  
10.0V at 3mV/V Sensitivity  
3.333V at 3mV/V Sensitivity  
10.0V at 3mV/V Sensitivity  
10.0V at 2mV/V Sensitivity  
3.333V at 10mV/V Sensitivity  
10.0V at 10mV/V Sensitivity  
-5V to +5V  
–5V to +5V  
-5V to +5V  
–5V to +5V  
–5V to +5V  
–5V to +5V  
–5V to +5V  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OM5-IVI  
Current Output Modules  
DESCRIPTION  
FEATURES  
Each OM5-IVI current output module provides a single channel of analog  
output. The track-and-hold circuit in the input stage can be operated in a  
hold mode where one DAC can supply many output modules, or a track  
mode where one DAC is dedicated to each module. In addition to the track-  
and-hold circuit, each module provides signal buffering, isolation, filtering,  
and conversion to a high level current output (Figure 1).  
ACCEPTS HIGH LEVEL VOLTAGE OR PROCESS CURRENT INPUT  
UNIPOLAR OR BIPOLAR CURRENT OUTPUT  
1500Vrms TRANSFORMER ISOLATION  
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION  
OUTPUT PROTECTED TO 240VAC CONTINUOUS  
110dB CMR  
Setting of the track or hold mode is controlled by the logic state of WR EN\,  
module pin 23. When pin 23 is low, the track mode is enabled. If pin 23  
is open or high, the hold mode is enabled. The module is designed with a  
completely isolated computer side circuit which can be floated to 50V  
from Power Common, pin 16. This complete isolation means that no  
connection is required between I/O Common and Power Common for  
proper operation of the track and hold circuit. For a low state, simply  
connect pin 23, the Write-Enable pin, to I/O Common, pin 19.  
400Hz SIGNAL BANDWIDTH  
0.05% ACCURACY  
0.02% LINEARITY  
CSA CERTIFIED, FM APPROVED, CE COMPLIANT  
MIX AND MATCH OM5 TYPES ON BACKPANEL  
The OM5-BP-16-MUX backpanels allow host computer control of the WR  
EN\ control line, which allows multiplexing of one host DAC to up to 64  
OM5-IVI output modules. During power-up, the output remains at 0mA for  
100ms on all models, which allows the track-and-hold circuit to be  
initialized.  
A special circuit in the output stage of the module provides protection  
against accidental connection of power-line voltages up to 240VAC.  
Isolation Barrier  
Track  
&
Hold  
18  
19  
23  
Range  
Select  
VIN / +IIN  
+EXC  
4
NC  
4
+Out  
6
5
3
I/O Common / –IIN  
WR EN\  
Surge  
Suppression  
and  
RLOAD  
3
2
1
Protection  
–Out  
+V  
–V  
NC  
–EXC  
Isolated  
Computer-Side  
Power  
Backpanel  
Term Block  
1
NC  
NC  
2
17  
16  
+5V  
Isolated  
Field-Side  
Power  
Power  
Oscillator  
Power Common  
FIGURE 1. OM5-IVI Block Diagram.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONSTypical at TA = +25°C and +5V power.  
Unipolar Output Current  
OM5-IVI  
Module  
Input Voltage Range  
5V or 0V to +5V  
0 to 20mA  
Input Current Range (–05)  
Input Voltage Maximum  
Input Current, Maximum (–05)  
Input Resistance  
36V (no damage)  
75mA (no damage)  
50MΩ  
Input Resistance (–05)  
20Ω  
Output Current Range  
Over Range Capability  
Output Compliance Voltage  
(Open Circuit)  
0 to 20mA or 4 to 20mA  
10%  
22VDC  
0 to 650Ω  
Load Resistance Range  
(0 to 750for Power Supply Voltage  
greater than 4.95VDC)  
26mA  
Output I Under Fault, max  
Output Protection  
Continuous  
240Vrms max  
Transient  
ANSI/IEEE C37.90.1-1989  
CMV, Output to Input  
Continuous  
Transient  
CMR (50Hz or 60Hz)  
NMR (–3dB at 400 Hz)  
1500Vrms max  
ANSI/IEEE C37.90.1-1989  
110dB  
40dB per Decade above 400Hz  
Accuracy  
Nonlinearity  
0.05% Span  
0.02% Span  
Stability  
Zero  
Span  
Noise  
0.5µA/°C  
20ppm/°C  
Output Ripple, 1kHz bandwidth  
Bandwidth, –3dB  
Rise Time, 10 to 90% Span  
10µAp-p  
400Hz  
0.75ms  
Sample and Hold  
Output Droop Rate  
Acquisition Time  
40µA/s  
50µs  
Track-and-Hold Enable Control  
Max Logic “0”  
Min Logic “1”  
Max Logic “1”  
Input Current, “0”  
+0.8V  
+2.4V  
+36V  
0.5µA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
+5VDC 5%  
170mA  
0.5µA/% typ  
Mechanical Dimensions  
2.28" x 2.26" x 0.6" (58mm x 57mm x 15mm)  
Environmental  
Operating Temp. Range  
Storage Temp. Range  
Relative Humidity  
Emissions  
–40°C to +85°C  
–40°C to +85°C  
0 to 95% Noncondensing  
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)  
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)  
Immunity  
* same specification  
ORDERING INFORMATION  
MODEL  
INPUT RANGE OUTPUT RANGE BANDWIDTH  
OM5-IVI-B4-C  
OM5-IVI-A4-C  
OM5-IVI-B0-C  
OM5-IVI-A0-C  
0V to +5V  
–5V to +5V  
0V to +5V  
–5V to +5V  
4mA to 20mA  
4mA to 20mA  
0mA to 20mA  
0mA to 20mA  
400Hz  
400Hz  
400Hz  
400Hz  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY/DISCLAIMER  
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a  
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace  
period to the normal one (1) year product warranty to cover handling and shipping time.  
This  
ensures that OMEGA's customers receive maximum coverage on each product.  
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer  
Service Department will issue an Authorized Return (AR) number immediately upon phone or written  
request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at  
no charge. OMEGA's WARRANTY does not apply to defects resulting from any action of the purchaser,  
including but not limited to mishandling, improper interfacing, operation outside of design limits,  
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  
having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or  
current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating  
conditions outside of OMEGA's control. Components which wear are not warranted, including but not  
limited to contact points, fuses, and triacs.  
OMEGA is pleased to offer suggestions on the use of its various products.  
However,  
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any  
damages that result from the use of its products in accordance with information provided by  
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be  
as specified and free of defects.  
OMEGA MAKES NO OTHER WARRANTIES OR  
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF  
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.  
LIMITATION OF  
LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of  
OMEGA with respect to this order, whether based on contract, warranty, negligence,  
indemnification, strict liability or otherwise, shall not exceed the purchase price of the  
component upon which liability is based.  
consequential, incidental or special damages.  
In no event shall OMEGA be liable for  
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic  
Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical  
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or  
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility  
as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify  
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the  
Product(s) in such a manner.  
RETURN REQUESTS/INQUIRIES  
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE  
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN  
(AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID  
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return  
package and on any correspondence.  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent  
breakage in transit.  
FOR WARRANTY RETURNS, please have the  
following information available BEFORE  
contacting OMEGA:  
FOR NON-WARRANTY REPAIRS, consult OMEGA  
for current repair charges. Have the following  
information available BEFORE contacting OMEGA:  
1. P.O. number under which the product was  
PURCHASED,  
1. P.O. number to cover the COST  
of the repair,  
2. Model and serial number of the product under  
warranty, and  
3. Repair instructions and/or specific problems  
relative to the product.  
2. Model and serial number of the product, and  
3. Repair instructions and/or specific problems  
relative to the product.  
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords  
our customers the latest in technology and engineering.  
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.  
© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,  
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior  
written consent of OMEGA ENGINEERING, INC.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEMPERATURE  
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies  
Wire: Thermocouple, RTD & Thermistor  
Calibrators & Ice Point References  
Recorders, Controllers & Process Monitors  
Infrared Pyrometers  
þ
þ
þ
þ
þ
PRESSURE, STRAIN AND FORCE  
Transducers & Strain Gauges  
Load Cells & Pressure Gauges  
Displacement Transducers  
þ
þ
þ
þ
Instrumentation & Accessories  
FLOW/LEVEL  
Rotameters, Gas Mass Flowmeters & Flow Computers  
Air Velocity Indicators  
Turbine/Paddlewheel Systems  
þ
þ
þ
þ
Totalizers & Batch Controllers  
pH/CONDUCTIVITY  
pH Electrodes, Testers & Accessories  
Benchtop/Laboratory Meters  
Controllers, Calibrators, Simulators & Pumps  
Industrial pH & Conductivity Equipment  
þ
þ
þ
þ
DATA ACQUISITION  
Data Acquisition & Engineering Software  
Communications-Based Acquisition Systems  
Plug-in Cards for Apple, IBM & Compatibles  
Datalogging Systems  
þ
þ
þ
þ
þ
Recorders, Printers & Plotters  
HEATERS  
Heating Cable  
þ
þ
þ
þ
þ
Cartridge & Strip Heaters  
Immersion & Band Heaters  
Flexible Heaters  
Laboratory Heaters  
ENVIRONMENTAL  
MONITORING AND CONTROL  
Metering & Control Instrumentation  
Refractometers  
Pumps & Tubing  
Air, Soil & Water Monitors  
Industrial Water & Wastewater Treatment  
pH, Conductivity & Dissolved Oxygen Instruments  
þ
þ
þ
þ
þ
þ
M1516  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Refrigerator F 1471 User Manual
Miele Washer W 844 User Manual
Multiquip Portable Generator ga6HB User Manual
Murphy Switch MDTM89 User Manual
NAD CD Player C521i User Manual
NAD Stereo Receiver 7020i User Manual
NETGEAR Security Camera VZCN2060 100NAS User Manual
Nokia Portable Speaker MD 6 User Manual
NuTone Ventilation Hood NP50000 User Manual
Omega Thermostat DP25B TC User Manual