Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
GENERAL DESCRIPTION.............................................................................................................. 2
OM5 SELECTION GUIDE ............................................................................................................... 2
ANALOG VOLTAGE INPUT MODULES, NARROW BANDWIDTH: OM5-IMV/IV ....................... 4
ANALOG CURRENT INPUT MODULES: OM5-II .......................................................................... 6
TRUE RMS INPUT MODULES: OM5-IAC ..................................................................................... 8
LINEARIZED 2- OR 3-WIRE RTD INPUT MODULES: OM5-IP/IC/IN ..............................................10
LINEARIZED 4-WIRE RTD INPUT MODULES: OM5-IP4/IC4/IN4.............................................. 12
POTENTIOMETER INPUT MODULES: OM5-PT......................................................................... 14
THERMOCOUPLE INPUT MODULES: OM5-ITC ........................................................................ 16
STRAIN GAGE INPUT MODULES, WIDE BANDWIDTH: OM5-WBS ....................................... 16
ANALOG CURRENT OUTPUT MODULES: OM5-IVI ................................................................. 20
ANALOG VOLTAGE INPUT MODULES, WIDE BANDWIDTH: OM5-WMV/WV ....................... 22
2-WIRE TRANSMITTER INTERFACE MODULES: OM5-TX ............................................................ 24
GENERAL PURPOSE INPUT MODULES, DC EXCITATION: OM5-DT .................................... 26
FREQUENCY INPUT MODULES: OM5-IFI ................................................................................ 28
LINEARIZED THERMOCOUPLE INPUT MODULES: OM5-LTC...................................................... 30
VOLTAGE OUTPUT MODULES, 50mA DRIVE CAPACITY: OM5-AV ...................................... 32
DIMENSIONS AND ACCESSORIES ............................................................................................ 34
1
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-WMV/WV
Analog Voltage Input Modules, Wide Bandwidth
DESCRIPTION
FEATURES
Each OM5 wide bandwidth voltage input module provides a single channel
of analog input which is amplified, isolated, and converted to a high level
analog voltage output (Figure 1). This voltage output is logic-switch
controlled, allowing these modules to share a common analog bus without
the requirement of external multiplexers.
● ACCEPTS MILLIVOLT AND VOLTAGE LEVEL SIGNALS
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
The OM5 modules are designed with a completely isolated computer side
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 100dB CMR
● 10kHz SIGNAL BANDWIDTH
●
●
●
0.05% ACCURACY
0.02% LINEARITY
1µV/°C DRIFT
The input signal is processed through a pre-amplifier on the field side of
the isolation barrier. This pre-amplifier has a gain-bandwidth product of
5MHz and is bandwidth limited to 10kHz. After amplification, the input
signal is chopped by a proprietary chopper circuit. Isolation is provided by
transformer coupling, again using a proprietary technique to suppress
transmission of common mode spikes or surges. The module is powered
from +5VDC, 5%.
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
A special input circuit provides protection against accidental connection of
power-line voltages up to 240VAC.
4
NC
Anti-Aliasing
Filter
Isochopper™
20
+EXC
+In
LPF
Amplifier
VOUT
4
3
2
1
Surge
Suppression
and
Pat Pending
6
VIN
19
22
5
3
I/O Common
RD EN\
Protection
+V
–V
–In
–EXC
NC
Isolated
Computer-Side
Power
Backpanel
Term Block
1
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-WMV/WV Block Diagram.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V Power.
Module
OM5-WMV
OM5-WV
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
10mV to 100mV
0.5nA
1V to 40V
0.05nA
200MΩ
40kΩ
40kΩ
650kΩ (minimum)
650kΩ (minimum)
650kΩ (minimum)
240Vrms Max
ANSI/IEEE C37.90.1-1989
*
*
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
NMR (–3dB at 10kHz)
1500Vrms max
ANSI/IEEE C37.90.1-1989
100dB
*
*
*
*
120dB per Decade above 10kHz
Accuracy(1)
0.05% Span 10µV RTI(2) 0.05%(VZ(3)
)
0.05% span 0.2mV RTI(2)
0.05% (VZ(3)
*
)
Nonlinearity
0.02% Span
Stability
Input Offset
Output Offset
Gain
1µV/°C
40µV/°C
25ppm/°C
20µV/°C
*
50ppm/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Rise Time, 10 to 90% Span
Settling Time, to 0.1%
0.4µVrms
10mVp-p
10kHz
35µs
250µs
2µVrms
*
*
*
*
Output Range
5V or 0V to +5V
50Ω
*
*
*
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
Output Current Limit
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
)
*
*
8mA
Output Enable Control
Max Logic “0”
+0.8V
+2.4V
+36V
*
*
*
*
Min Logic “1”
Max Logic “1”
Input Current, “0”, “1”
0.5µA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
*
*
2µV/% RTI(2)
200µV/% RTI(2)
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
*
* Same specification as OM5-
WMV.
NOTES: (1) Includes nonlinearity,
hysteresis and repeatability.
(2) RTI = Referenced to input.
(3) V is the input voltage
that rZesults in 0V output.
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
*
*
*
*
0 to 95% Noncondensing
EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
*
ORDERING
INFORMATION
MODEL
OM5-WMV-10A-C
OM5-WMV-50A-C
OM5-WMV-100A-C –100mV to +100mV
OM5-WMV-10B-C
OM5-WMV-50B-C
INPUTRANGE
–10mV to +10mV
–50mV to +50mV
OUTPUTRANGE
–5V to +5V
–5V to +5V
–5V to +5V
0V to +5V
0V to +5V
0V to +5V
–5V to +5V
–5V to +5V
–5V to +5V
0V to +5V
0V to +5V
0V to +5V
–5V to +5V
0V to +5V
–5V to +5V
0V to +5V
–10mV to +10mV
–50mV to +50mV
OM5-WMV-100B-C –100mV to +100mV
OM5-WV-1A-C
OM5-WV-5A-C
OM5-WV-10A-C
OM5-WV-1B-C
OM5-WV-5B-C
OM5-WV-10B-C
OM5-WV-20A-C
OM5-WV-20B-C
OM5-WV-40A-C
OM5-WV-40B-C
–1V to +1V
–5V to +5V
–10V to +10V
–1V to +1V
–5V to +5V
–10V to +10V
–20V to +20V
–20V to +20V
–40V to +40V
–40V to +40V
23
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-TX
2-Wire Transmitter Interface Modules
FEATURES
● ISOLATED +20VDC CURRENT LOOP SUPPLY
ter. This allows a 2-wire loop powered transmitter to be directly connected
to the module without requiring an external power supply. The regulated
supply will provide a nominal +20VDC at a loop current of 4mA to 20mA.
● PROVIDES ISOLATION FOR NON-ISOLATED 2-WIRE
The OM5-TX will provide a 1500V isolation barrier for non-isolated 2-wire
field transmitters. It can also be used when additional isolation is required
between an isolated 2-wire transmitter and the input stage of the control
room computer.
TRANSMITTERS
● HIGH LEVEL VOLTAGE OUTPUT: +1V to +5V or +2V to +10V
●
1500Vrms TRANSFORMER ISOLATION
The voltage output is logic switch controlled, which allows these modules
to share a common analog bus without the requirement of external
multiplexers.
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 100dB CMR
The modules are designed with a completely isolated computer side circuit
which can be floated to 50V from Power Common, pin 16. This complete
isolation means that no connection is required between I/O Common and
Power Common for proper operation of the output switch. If desired, the
output switch can be turned on continuously by simply connecting pin 22,
the Read-Enable pin to I/O Common, pin 19.
● 100Hz SIGNAL BANDWIDTH
●
●
0.05% ACCURACY
0.02% LINEARITY
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
A precision 20Ω current conversion resistor is supplied with the module.
Sockets are provided on the OM5-BP backpanels to allow installation of
this resistor. Extra resistors are available under part number OMX-1362-C.
All field inputs are fully protected from accidental connection of power-line
voltages up to 240VAC. The module has a 3dB bandwidth of 100Hz. Signal
filtering is accomplished with a six-pole filter, with two poles on the field
side of the isolation barrier, and the other four on the computer side.
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
Each OM5-TX 2-wire transmitter interface module provides a single chan-
nel which accepts a 4 to 20 mA process current input and provides a
standard +1 to +5V or +2 to +10V output signal (Figure 1). An isolated
+20VDC regulated power supply is provided to power the current transmit-
2-Wire
Transmitter
+EXC
+In
4
6
LPF
Isochopper™
20
4
3
2
1
LPF
Amplifier
VOUT
Surge
Suppression
and
Pat Pending
19
22
5
3
I/O Common
RD EN\
Protection
–In
+V
–V
Isolated
Excitation
Source
–EXC
Isolated
20
Ω
Computer-Side
Power
0.1% plug-in
OMX-1362-C
Backpanel
Term Block
1
NC
NC
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power
Common
FIGURE 1. OM5-TX Block Diagram.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Module
OM5-TX
Input Range
Input Resistor
Value
4mA to 20mA
20.00Ω
0.1%
Accuracy
Stability
Loop Supply Voltage
10ppm/°C
Nominal 20V at 4mA to 20mA
Isolated Excitation Protection
Continuous
Transient
240Vrms max
ANSI/IEEE C37.90.1-1989
Input Protection
Continuous
Transient
240Vrms max
ANSI/IEEE C37.90.1-1989
CMV, Input to Output
Continuous
Transient
1500Vrms max
ANSI/IEEE C37.90.1-1989
CMR (50 or 60Hz)
NMR (–3dB at 100Hz)
100dB
120dB per decade above 100Hz
Accuracy(1)
Nonlinearity
Stability
0.05% span 4µA RTI(2)
0.02% span
Input Offset
Output Offset
Gain
1µV/°C
40µV/°C
25ppm/°C of reading
Noise
Input, 0.1 to 10Hz
Output, 100KHz
Bandwidth, –3dB
Response Time, 90% span
10nArms
500µVrms
100Hz
4mS
Output Range
+1V to +5V or +2V to +10V
50Ω
Continuous short to gnd
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
+0.8V
+2.4V
+36V
Max Logic “1”
Input Current, “0, 1”
0.5µA
Power Supply Voltage
Power Supply Current
+5VDC 5%
180mA at transmitter load of 20mA
100mA at transmitter load of 4mA
10µV/% RTI(2)
Power Supply Sensitivity
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
0 to 95% noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.
(2) RTI = Referenced to input.
ORDERINGINFORMATION
MODEL
INPUTRANGE
OUTPUTRANGE
OM5-TX-1-C
OM5-TX-2-C
4mA to 20mA
4mA to 20mA
+1V to +5V
+2V to +10V
25
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-DT
General Purpose Input Modules, with DC Excitation
FEATURES
controlled, which allows these modules to share a common analog bus
without the requirement of external multiplexers.
● INTERFACES TO DC DISPLACEMENT TRANSDUCERS AND OTHER
DEVICES REQUIRING A STABLE DC SUPPLY
The modules are designed with a completely isolated computer side circuit
which can be floated to 50V from Power Common, pin 16. This complete
isolation means that no connection is required between I/O Common and
Power Common for proper operation of the output switch. If desired, the
output switch can be turned on continuously by simply connecting pin 22,
the Read-Enable pin to I/O Common, pin 19.
● HIGH LEVEL VOLTAGE OUTPUTS
●
1500Vrms TRANSFORMER ISOLATION
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● FULLY ISOLATED EXCITATION SUPPLY
● 100dB CMR
The OM5-DT can interface to devices which require a precision 10VDC
excitation supply. The 1kHz bandwidth significantly reduces ripple and
noise inherent in these devices.
Transducer excitation is provided from the module by a very stable 10V
source. The excitation supply is fully isolated, allowing the amplifier inputs
to operate over the full range of the excitation voltage. This feature offers
significant flexibility in real world applications. Eight full scale input ranges
are provided, from 1V to 10V, producing 5V full scale output.
● 1KHz SIGNAL BANDWIDTH
●
●
●
0.10% ACCURACY
0.02% LINEARITY
20µV/°C DRIFT
The input signal is processed through a pre-amplifier on the field side of
the isolation barrier. This pre-amplifier has a gain-bandwidth product of
5MHz and is bandwidth limited to 1kHz. After amplification, the input signal
is chopped by a proprietary chopper circuit. Isolation is provided by
transformer coupling, again using a proprietary technique to suppress
transmission of common mode spikes or surges. The module is powered
from +5VDC, 5%.
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
Each OM5-DT general purpose input module provides a single channel of
transducer input which is filtered, isolated, scaled, and converted to a high
level analog voltage output (Figure 1). This voltage output is logic switch
Special input circuits provide protection of the signal inputs and the
isolated excitation supply up to 240VAC.
+EXC
+In
4
LPF
Isochopper™
20
4
3
2
1
LPF
Amplifier
VOUT
Surge
Suppression
and
6
5
3
Pat Pending
DC LVDT
or Other
Transducer
19
22
Protection
I/O Common
RD EN\
+V
–V
–In
Isolated
Excitation
Source
Isolated
Computer-Side
Power
–EXC
Backpanel
Term Block
1
NC
2
NC
+V
17
16
+5V
Isolated
Field-Side
Power
Power
Oscillator
–V
Power
Common
FIGURE 1. OM5-DT Block Diagram.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Module
OM5-DT
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
1V to 10V
0.05nA
2MΩ (minimum)
2MΩ (minimum)
2MΩ (minimum)
240Vrms max
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)
Excitation Voltage, VEXC
Excitation current
Excitation Load Regulation
Excitation Stability
Isolated Excitation Protection
Continuous
+10.0VDC 2mV
40mA (maximum)
5ppm/mA
15ppm/°C
240Vrms max
Transient
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)
CMV, Input to Output
Continuous
Transient
CMR (50 or 60Hz)
NMR (–3dB at 1kHz)
1500Vrms max
ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)
100dB
120dB per decade above 1kHz
Accuracy(1)
Nonlinearity
0.1% span, 0.2mV RTI2
0.02% span
Stability
Input Offset
Output Offset
Gain
20µV/°C
40µV/°C
50ppm/°C
Noise
Input, 0.1 to 10Hz
Output, 100KHz
0.4µVrms
5mVpp
Bandwidth, –3dB
Response Time (to 90% final value)
1kHz
750µs
Output Range
5V
50Ω
Output Resistance
Output Protection
Output Selection Time
Continuous short to ground
6.0µs at Cload = 0 to 2000pF
(to 1mV of VOUT
)
Output Current Limit
8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
+0.8V
+2.4V
+36V
Max Logic “1”
Input Current, “0, 1”
0.5µA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
200mA @ Full Exc. load, 100mA @ No Exc. Load
200µV/% RTI(2)
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
0 to 95% noncondensing
ORDERINGINFORMATION
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
MODEL
MAXIMUM INPUT
OUTPUT
Immunity
OM5-DT-1-C
OM5-DT-2-C
OM5-DT-3-C
OM5-DT-4-C
OM5-DT-5-C
OM5-DT-6-C
OM5-DT-7-C
OM5-DT-8-C
OM5-DT-9-C
OM5-DT-10-C
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
5V
5V
5V
5V
5V
5V
5V
5V
5V
5V
NOTES:
(1) Includes excitation error, nonlinearity, hysteresis and repeatability.
(2) RTI = Referenced to input.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IFI
Frequency Input Modules
FEATURES
DESCRIPTION
● ACCEPTS FREQUENCY INPUTS OF 0 to 100kHz
● PROVIDES HIGH LEVEL VOLTAGE OUTPUTS
● TTL LEVEL INPUTS
Each OM5-IFI Frequency input module provides a single channel of fre-
quency input which is isolated and converted to a high level analog voltage
output. This voltage output is logic switch controlled, which allows these
modules to share a common analog bus without the requirement of external
multiplexers (Figure 1).
● 1500 VOLT TRANSFORMER ISOLATION
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 0.05% ACCURACY
The frequency input signal can be a TTL level signal or a zero-crossing signal.
Terminal 3 (+In) on the field-side terminal block is the “common” or ground
connection for input signals. A TTL signal is connected from terminal 2 (–In)
to terminal 3 (+In), while a zero-crossing signal is connected from terminal 4
(+EXC) to terminal 3 (+In). Input circuitry for each of the signal types has
hysteresis built in. An input signal must cross entirely through the hysteresis
region in order to trigger the threshold comparator.
● MIX AND MATCH OM5 TYPES ON BACKPANEL
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
A 5.1V excitation is available for use with magnetic pick-up or contact-
closure type sensors. The excitation is available on pin 1 (–EXC) and the
excitation common is pin 3 (+In).
The modules are designed with a completely isolated computer side circuit
which can be floated to 50V from Power Common, pin 16. This complete
isolation means that no connection is required between I/O Common and
Power Common for proper operation of the output switch. If desired, the
output switch can be turned on continuously by simply connecting pin 22,
the Read-Enable pin to I/O Common, pin 19.
A special circuit in the input stage of the module provides protection against
accidental connection of power-line voltages up to 240VAC.
Threshold
Comparator
F to V
Zero-Crossing
4
6
Inputs
+
+EXC
+In
Signal
Isolation
20
4
3
2
1
LPF
VOUT
Surge
Suppression
and
–
–
+
TTL
Inputs
–In
19
22
5
3
I/O Common
RD EN\
Protection
+V
–V
–EXC
Isolated
Computer-Side
Power
5.1V
Backpanel
Term Block
1
NC
NC
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-IFI Block Diagram.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at Ta = +25C and +5V Power
Module
OM5-IFI
Input Range
Input Threshold
Minimum Input
Maximum Input
Minimum Pulse Width
TTL Input Low
TTL Input High
Input Hysteresis
Zero Crossing
TTL
0 to 100KHz
Zero Crossing
60mVp-p
350Vp-p
4µs
0.8V max
2.4V min
0.04V
1.5V
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
100KΩ
100KΩ
100KΩ
240Vrms max
ANSI/IEEE C37.90.1-1989
+5.1V @ 8mA max
Transient
Excitation
CMV, Input to Output
Continuous
Transient
1500Vrms max
ANSI/IEEE C37.90.1-1989
120dB
CMR (50 or 60Hz)
Accuracy(1)
Nonlinearity
0.05% span
0.02% span
Stability
Offset
Gain
Noise
40ppm/°C
40ppm/°C
Output Ripple
Response Time (0 to 90%)
OM5-IFI-500/1K-C
OM5-IFI-3K-C
OM5-IFI-5K/10K-C
OM5-IFI-25K/50K/100K-C
<10mVp-p @ Input >2% span
300 ms
170 ms
90 ms
20 ms
Output Range
0V to +5V
50Ω
Continuous short to ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
+0.8V
+2.4V
+36V
Max Logic “1”
Input Current, “0,1”
0.5µA
ORDERINGINFORMATION
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
110mA
150µV/% RTO
MODEL
INPUTRANGE
OUTPUTRANGE
(2)
OM5-IFI-500-C
OM5-IFI-1K-C
OM5-IFI-3K-C
OM5-IFI-5K-C
OM5-IFI-10K-C
OM5-IFI-25K-C
OM5-IFI-50K-C
OM5-IFI-100K-C
0 to 500Hz
0 to 1kHz
0 to 3kHz
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
-40°C to +85°C
-40°C to +85°C
0 to 95% noncondensing
0 to 5kHz
0 to 10kHz
0 to 25kHz
0 to 50kHz
0 to 100kHz
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.
(2) RTO = Referenced to Output.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-LTC
Linearized Thermocouple Input Modules
FEATURES
● INTERFACES TO TYPES J, K, T, E, R, S, N, AND B
The OM5-LTC modules are designed with a completely isolated computer
side circuit which can be floated to 50V from Power Common, pin 16.
This complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
THERMOCOUPLES
● LINEARIZES THERMOCOUPLE SIGNAL
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
The OM5-LTC can interface to eight industry standard thermocouple types:
J, K, T, E, R, S, N, and B. Its corresponding output signal operates over a
0V to +5V range. Each module is cold-junction compensated to correct for
parasitic thermocouples formed by the thermocouple wire and screw
terminals on the mounting backpanel. Upscale open thermocouple detect
is provided by an internal pull-up resistor. Downscale indication can be
implemented by installing an external 47MΩ resistor, 20% tolerance,
between screw terminals 1 and 3 on the OM5-BP backpanels.
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
● 95dB NMR AT 60Hz, 90dB at 50Hz
●
1µV/°C DRIFT
Signal filtering is accomplished with a six-pole filter which provides 95dB
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter
are on the field side of the isolation barrier, and the other four are on the
computer side.
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
After the initial field-side filtering, the input signal is chopped by a
proprietary chopper circuit. Isolation is provided by transformer coupling,
again using a proprietary technique to suppress transmission of common
mode spikes or surges. The module is powered from +5VDC, 5%.
DESCRIPTION
Each OM5-LTC thermocouple input module provides a single channel of A special input circuit provides protection against accidental connection of
thermocouple input which is filtered, isolated, amplified, linearized and power-line voltages up to 240VAC.
converted to a high level analog voltage output (Figure 1). This voltage
output is logic-switch controlled, allowing these modules to share a
common analog bus without the requirement of external multiplexers.
+2.5V
100MΩ
20
VOUT
Linearizer
LPF
4
NC
+EXC
+In
LPF
Isochopper™
Amplifier
Pat Pending
4
3
2
1
19
22
I/O Common
RD EN\
Surge
Suppression
and
6
Thermocouple
5
3
Protection
+V
–V
–In
–EXC
Isolated
Computer-Side
Power
Precision
Reference
Backpanel
Term Block
CJC
1
2
17
+V
–V
+5V
Temp
Sensor
Isolated
Field-Side
Power
Power
Oscillator
16
Power Common
FIGURE 1. OM5-LTC Block Diagram.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Module
OM5-LTC
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
–0.1V to +0.5V
–25nA
50MΩ
40kΩ
40kΩ
240Vrms max
ANSI/IEEE C37.90.1-1989
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
95dB at 60Hz, 90dB at 50Hz
Accuracy
See Ordering Information
Stability
Input Offset
Output Offset
Gain
1µV/°C(1)
20µV/°C
25ppm/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% Span
0.2µVrms
300µVp-p, 150µVrms
4Hz
0.2s
Output Range
0V to +5V
50Ω
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
+0.8V
+2.4V
+36V
Min Logic “1”
Max Logic “1”
Input Current, “0”, “1”
Open Input Response
Open Input Detection Time
Cold Junction Compensation
Accuracy, 25°C
0.5µA
Upscale
10s
0.25°C
0.5°C
1.25°C
Accuracy, +5°C to +45°C
Accuracy, –40°C to +85°C
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
2µV/% RTI(2)
Mechanical Dimensions
2.28" x 2.26" x 0.6"
(58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
NOTES: (1) This is equivalent to °C as follows:
Type J 0.020 °C/°C, Types K, T 0.025°C/°C,
Type E 0.016°C/°C, Types R, S 0.168°C/°C,
Type N 0.037°C/°C, Type C 0.072°C/°C.
(2) Referenced to input.
0 to 95% Noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
MODEL
TYPE
INPUT RANGE
OUTPUT RANGE
ACCURACY†
ORDERING
OM5-LTC-J1-C
OM5-LTC-J2-C
OM5-LTC-J3-C
OM5-LTC-J4-C
OM5-LTC-K1-C
OM5-LTC-K2-C
OM5-LTC-K3-C
OM5-LTC-T1-C
OM5-LTC-T2-C
OM5-LTC-E-C
OM5-LTC-R-C
OM5-LTC-S-C
OM5-LTC-B-C
Type J
Type J
Type J
Type J
Type K
Type K
Type K
Type T
Type T
Type E
Type R
Type S
Type B
0°C to +760°C (+32°F to +1400°F)
-100°C to +300°C (-148°F to +572°F)
0°C to +500°C (+32°F to 932°F)
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0.08%
0.08%
0.07%
0.08%
0.08%
0.08%
0.08%
0.16%
0.13%
0.10%
0.10%
0.10%
0.15%
0.61°C
0.32°C
0.36°C
0.70°C
0.80°C
0.38°C
1.2°C
INFORMATION
-100°C to +760°C (-148°F to +1400°F)
0°C to +1000°C (+32°F to +1832°F)
0°C to +500°C (+32°F to +932°F)
-100°C to +1350°C (-148°F to +2462°F)
-100°C to +400°C (-148°F to +752°F)
0°C to +200°C (+32°F to +392°F)
0°C to +1000°C (+32°F to +1832°F)
+500°C to +1750°C (+932°F to +3182°F)
+500°C to +1750°C (+932°F to +3182°F)
+500°C to +1800°C (+932°F to +3272°F)
0.80°C
0.25°C
1.0°C
1.3°C
†Includes conformity,
hysteresis and
1.3°C
2.0°C
repeatability. Does not
include CJC accuracy.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-AV
Voltage Output Modules
FEATURES
DESCRIPTION
● ACCEPTS HIGH LEVEL VOLTAGE INPUTS TO 10V
● PROVIDES HIGH LEVEL VOLTAGE OUTPUTS TO 10V
● 1500 VOLT TRANSFORMER ISOLATION
● ANSI/IEEE C37.90.1e-1989 TRANSIENT PROTECTION
● 5 POLES OF FILTERING
Each OM5-AV voltage output module provides a single channel of analog
output. Thetrack-and-holdcircuitintheinputstagecanbeoperatedinahold
mode where one DAC can supply many output modules, or a track mode
whereoneDACisdedicatedtoeachmodule. Inadditiontothetrack-and-hold
circuit, each module provides signal buffering, isolation, filtering, and
conversion to a high level voltage output.
Setting of the track or hold mode is controlled by the logic state of WR EN\,
module pin 23. When pin 23 is low, the track mode is enabled. If pin 23 is
open or high, the hold mode is enabled. The module is designed with a
completely isolated computer side circuit which can be floated to 50V from
Power Common, pin 16. This complete isolation means that no connection
is required between I/O Common and Power Common for proper operation
of the track and hold circuit. For a low state, simply connect pin 23, the Write-
Enable pin, to I/O Common, pin 19.
● 110dB CMR
● 400Hz SIGNAL BANDWIDTH
● 0.05% ACCURACY
● 0.02% LINEARITY
● MIX AND MATCH OM5 TYPES ON BACKPANEL
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
The OM5-BP-MUX-C backpanels allow host computer control of the WR EN\
control line, which allows multiplexing of one host DAC to up to 64 OM5-AV
output modules. During power up, the output remains 0V output for 100ms,
which allows the track-and-hold circuit to be initialized.
Isolation Barrier
Track
&
Hold
18
19
23
Range
Select
VIN
+EXC
4
NC
4
+Out
6
5
3
Surge
Suppression
and
I/O Common
WR EN\
RLOAD
3
2
1
Protection
–Out
+V
–V
NC
–EXC
Isolated
Computer-Side
Power
Backpanel
Term Block
1
NC
NC
2
17
16
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-AV Block Diagram.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA= +25C and +5V Power
Module
OM5-AV
Input Voltage Range
Input Voltage Maximum
Input Resistance
5V, 0 to +5V, 10V, 0 to +10V
36V (no damage)
50MΩ
Output Voltage Range
Over Range Capability
Output Drive
Output Resistance
Output I Under Fault, Max
Output Protection
Transient
5V, 0 to +5V, 10V, 0 to +10V
5% @ 10V output
50mA max
0.5Ω
75mA
ANSI/IEEE C37.90.1-1989
CMV, Output to Input
Continuous
Transient
CMR (50 or 60Hz)
NMR (–3dB at 400Hz)
1500Vrms max
ANSI/IEEE C37.90.1-1989
110dB
100dB per Decade above 400Hz
Accuracy(1)
Nonlinearity
0.05% span (0-5mA load)
0.02% span
Stability
Zero
Span
Noise
25ppm/°C
20ppm/°C
Output Ripple, 1kHz bandwidth
Bandwidth, -3dB
2mVp-p
400Hz
Sample and Hold
Output Droop Rate
Acquisition Time
0.2% Span/s
50µs
Track-and-Hold Enable Control
Max Logic “0”
Min Logic “1”
+0.8V
+2.4V
+36V
Max Logic “1”
Input Current, “0”
0.5µA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
350mA Full load, 135mA No load
12.5ppm/%
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
RFI Susceptibility
Emissions
-40°C to +85°C
-40°C to +85°C
0 to 95% noncondensing
0.5% Span error at 400MHz, 5W, 3ft
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
NOTES: (1) Includes nonlinearity, hysteresis and repeatability.
ORDERINGINFORMATION
MODEL
INPUTRANGE
OUTPUTRANGE
OM5-AV-1-C
OM5-AV-2-C
OM5-AV-3-C
OM5-AV-4-C
OM5-AV-5-C
OM5-AV-6-C
OM5-AV-7-C
0V to +5V
-5V to +5V
-5V to +5V
0V to +10V
-10V to +10V
-10V to +10V
-5V to +5V
-5V to +5V
-5V to +5V
0V to +5V
-10V to +10V
-10V to +10V
0V to +10V
-10V to +10V
33
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5
Module Dimensions and Pinouts
The following mechanical drawing is useful if designing circuit boards to
mount the OM5 modules. Many sockets are available which accept the
mounting pins. As an example, AMP Inc. provides a socket with part
number 50865-5. The captive nut for the 3mm mounting screw can be
obtained from PEM (Penn Engineering and Manufacturing), part number
KFS2-M3.
Top
2.255" (57.3mm)
[2.260" max (57.4mm)]
0.585" (14.9mm)
[0.590" max (15.0mm)]
2.270" (57.7mm)
[2.275" max (57.8mm)]
Side
0.20" (5.1mm)
0.095" (2.4mm)
0.375" (9.5mm)
1.175" (29.8mm)
1.650" (41.9mm)
0.145" (3.7mm)
0.345" (8.8mm)
Pin Diameter = 0.040" (1.02mm)
0.0750" (1.9mm)
0.150" (3.8mm)
Bottom
0.345" (8.8mm)
2.025" (51.4mm)
1.650" (41.9mm)
1.175" (29.8mm)
0.900" (22.9mm)
0.375" (9.5mm)
0
NOTES: (1) All dimensions are “Typical” unless otherwise noted.
(2) Mounting pin plating is 20µ in. gold.
23
17
23
22
22
WR EN\
WR EN\
RD EN\
RD EN\
Reserved
VOUT
Reserved
VOUT
VIN
I/O Common
+5V
I/O Common
VIN
+5V
Power Common Power Common
17
16
6
16
6
5
1
5
1
+In
+In
+EXC
+SEN
–In
–EXC
–SEN
–In
+EXC
+SEN
–EXC
–SEN
2
2
Top View
Bottom View
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
for OM5 Analog Modules
FEATURES
● SINGLE, DUAL, 8-, AND 16-POSITION BACKPANELS
● INTERFACE CABLES
● MODULE EVALUATION BOARD
● DIN RAIL MOUNT BACKPANELS
● CABLE-TO-SCREW-TERMINAL INTERFACE BOARD
● 19-INCH MOUNTING RACK FOR BACKPANELS
● MULTIPLEXED AND NON-MULTIPLEXED BACKPANELS
OM5-BP-16-C 16 POSITION ANALOG I/O BACKPANEL, NON-MULTIPLEXED
DESCRIPTION
Figure 2 for schematic). Field connections are terminated with four screw
terminals at each module site. Use system interface cable OMX-1315-XX-
C for connection to the host system.
The OM5-BP-16-C 16 channel backpanel (Figure 1) can accept any of the
OM5 analog modules in any mixture. It can be mounted on the OMX-1363-
C 19-inch metal rack. The OM5-BP-16-C has 16 non-addressable analog I/
O signal channels which provides each module with it’s own analog bus. The
moduleoutputswitchiscontinuously“on”whenusingthisbackpanelandall
sixteen module outputs are simultaneously accessible to high-speed data
acquisition (ADC) boards. A set of inter-channel bridge jumpers permits
connecting an input module’s output to an output module’s input, providing
two levels of isolation. A temperature sensor is mounted on each channel to
provide cold junction compensation for thermocouple input modules (See
SPECIFICATIONS
Operating Temperature:
–40°C to +85°C
95% relative humidity, non-condensing
Interface Connector:
Field
Logic
High Density Screw Clamp, 14 AWG Max
26-pin, male header connector
Inter-channel
Bridge Jumpers
17.4" (442.0mm)
17.1" (434.3mm)
11.3" (287.0mm)
7.6" (193.0mm)
3.9" (99.1mm)
0.15"
(3.8mm)
26 Conductor Male Pin
Connectors P1, P2(1)
P2P1
1.275"
(32.4mm)
3.47"
JP15
E3
E2
E1
(88.1mm)
3.05"
(77.5mm)
JP1
10.32 X 0.40
Ground Lug, Including
Nut and Lockwasher
J4
J1 J2 J3
OMX-CJC-C
Cold Junction
Compensation Circuit
Pin 2
Pin 1
Pin 1
Pin 2
+5VDC Supply
Sockets for Current Conversion Resistors, OMX-1362-C
0.08"
16
(2.0mm)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Channel
Swaged Standoff
Thru Hole 0.15" (3.8mm) Dia.
2.27"
(57.7mm)
0.093"
(2.4mm)
0.75" (19.1mm)
0.14" (3.6mm)
inside diameter
NOTES:
1. Connector is Berg 65863-075 or equivalent.
Mating Connector is Amp 49958-6 or equivalent.
Connectors P1 and P2 are wired in parallel for “daisy chaining” up to 4 boards.
FIGURE 1. OM5-BP-16-C Analog I/O Backpanel Dimensions.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2. OM5-BP-16-C Schematic.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
GROUNDING
ELECTRICAL
Figure 4 details the optional ground jumper configuration available on the
OM5-BP-16-C backpanel. Jumpers J1, J3, and J4 are factory installed.
P1 AND P2 CONNECTOR
Connection to the host system is made at connectors P1 and P2. These
connectors are electrically equivalent. Two connectors are provided to allow
both analog input and analog output from host systems having individual
input and output connectors.
Jumper J1 connects the AGND shield wires (pins 3, 6, 9, 12, 15, 18, 21, and
24) to the backpanel signal ground. This provides a ground connection
between the host system and backpanel. Jumper J1 is required if output
modules are used, or if there is no high impedance sense input (input low of
a differential or pseudo-differential system) on the host measurement sys-
tem.
ADJACENT CHANNEL JUMPERS
Adjacent channels may be connected together to provide an isolated output
signal from an isolated input module, providing two levels of 1500V
isolation. This capability is provided with the 15 jumpers labeled JP1
through JP15 on headers E1, E2, and E3. A simplified drawing of the OM5-
BP-16-C schematic for Channel 1 through 4 is shown in Figure 3.
Jumper J3 connects the SENSE line (pin 25) to the backpanel signal ground.
If the host system has the capability, this allows measuring the OM5-BP-16-
C ground potential.
For proper operation of the output switch or track-and-hold circuit when
usingtheOM5backpanels, acurrentpathmustexistbetweenthehostcontrol
logic power common and module I/O Common (module pin 19). This path
can be established on the OM5-BP-16-C via jumper J4. If this connection
exists elsewhere in the system, jumper J4 should be removed since possible
ground loops could exist. Other connections of power ground and signal
Example: Assume an OM5-IMV input module is installed in Channel 1
position and an OM5-IVI output module is installed in Channel 2 position.
IfJP1isinstalled,theoutputofChannel1isconnectedtotheinputofChannel
2, which provides two levels of 1500V isolation.
HD10, E1
JP1
JP2
JP3
JP4
P2
P1
P2
P1
3
1
2
3
4
5
6
1
5
7
OM5 Module
6
9
11
13
12
15
18
21
24
25
AGND
I/O COM 19
16 PWR COM
20
18
20
18
20
18
20
18
VOUT
VIN
VOUT
VIN
VOUT
VIN
VOUT
VIN
J3
J1
J4
Sense
J2
Power Common
Signal Ground
and
Grounding Bolt
CH 1
CH 2
CH 3
CH 4
R
1
FIGURE 3. OM5-BP-16-C Adjacent Channel Jumpers.
POWER
FIGURE 4. OM5-BP-16-C Grounding Diagram.
The OM5-BP-16-C backpanel requires external +5VDC 5% power. The ground usually occur at the A/D or D/A converter of the host measurement
chassis mounted OMX-976-C power supplies have adequate capacity to system.
power any combination of modules.
If the connection of power common and AGND shield wires exists in the host
FUSING
measurement system, an optional resistive connection between AGND and
the backpanel signal ground can be made via R1. R1 can be as large as 10K
ohms;100ohmsisarecommendedvalue. JumperJ2canbeusedtoconnect
the SENSE line to R1 when this ground configuration is used.
The OM5-BP-16-C backpanel power is fuse protected through F1. This is a
Littlefuse type 252004, 4 amp fuse. Zener diode DZ1 provides extra
protection by clamping the input power voltage to +5.6V. If the input supply
voltage connection is reversed, this zener diode will be forward biased and Forfullprotectionagainstlargeelectricaldisturbancesonthefield-sideofthe
fuse F1 will be blown.
OM5 modules, a #10-32 ground stud is provided on the backpanel. An
electricalconnectionbetweenthisgroundstudandsystemgroundshouldbe
provided with a large gauge wire of the shortest possible length. When this
connection is made, a possible ground loop could result through the AGND
shield wires and backpanel signal ground. If the application involves only
input modules and a differential input is used by the host measurement
system, J1 should be removed. Remember that J1 is required if output
modules are used or if the host system does not have differential inputs.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-16-MUX-C 16 POSITION ANALOG I/O BACKPANEL, MULTIPLEXED
DESCRIPTION
SPECIFICATIONS
Operating Temperature:
–40°C to +85°C
The OM5-BP-16-MUX-C 16 channel backpanel (Figure 5) can accept any
of the OM5 analog modules in any mixture. It can be mounted on the
OMX-1363-C 19-inch metal rack. The OM5-BP-16-MUX-C has two
analog buses; one for analog input and one for analog output. This two-
bus configuration takes advantage of the switch controlled outputs on the
input modules and the track-and-hold inputs on the output modules. A
temperature sensor is mounted on each channel to provide cold junction
compensation for thermocouple input modules (See Figure 6 for
schematic). Field connections are terminated with four screw terminals at
each module site. Up to four OM5-BP-16-MUX-C backpanels may be
daisy-chained. Use OMX-CAB-01-C cable for daisy chaining and OMX-
1315-XX-C cable for connecting to host computer.
95% relative humidity, non-condensing
Interface Connector:
Field
Logic
High Density Screw Clamp, 14 AWG Max
26-pin, male header connector
Address Input Logic Levels:
Max Logic “0”
0.8V
2.0V
Min Logic “1”
II Input Current, “0” or “1”
0.1µA max at 25°C
1.0µA max –25°C to +85°C
RD EN\ or WR EN\ Signal Delay
from Connector P1 to Channels 1-16
Standalone (address 0-15)
51ns at 25°C
64ns at –25°C to +85°C
100ns at 25°C
Expanded (address 16-63)
126ns at –25°C to +85°C
17.4" (442.0mm)
17.1" (434.3mm)
11.3" (287.0mm)
7.6" (193.0mm)
3.9" (99.1mm)
26 Conductor Male
Pin Connector P1(1)
0.15"
(3.8mm)
1.275"
(32.4mm)
3.47"
P1
(88.1mm)
E2
E1
4
3
2
1
0
3.05"
(77.5mm)
10.32 X 0.40
Ground Lug, Including
Nut and Lockwasher
OMX-CJC-C
Cold Junction
Compensation Circuit
Write Address
Selection Jumper
Sockets for Current Conversion Resistors, OMX-1362-C
Pin 2
Pin 1
+5VDC Supply
Channel
0.08"
16
(2.0mm)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Read Address
Selection Jumper
Swaged Standoff
Thru Hole 0.15" (3.8mm) Dia.
2.27"
(57.7mm)
0.093"
(2.4mm)
0.75" (19.1mm)
0.14" (3.6mm)
inside diameter
NOTES:
1. Connector is Berg 65863-075 or equivalent.
Mating Connector is Amp 49958-6 or equivalent.
FIGURE 5. OM5-BP-16-MUX-C Analog I/O Backpanel.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 6. OM5-BP-16-MUX-C Schematic.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
GROUNDING
ELECTRICAL
Figure 7 below details the optional ground jumper configuration available on
the OM5-BP-16-MUX-C backpanel. Jumpers J1, J2, and J4 are factory
installed.
P1 CONNECTOR
The 26 pin P1 connector provides the signal interface between the OM5-BP-
16-MUX-C backpanel and the host measurement system. Two separate
analog bus connections are provided; one for analog input signals and one
for analog output signals. Two sets of six address lines and an enable pin
allow input and output modules to be independently multiplexed onto their
respective analog signal bus. R0 thru R5 and RDENAB are used for input
modules, and W0 thru W5 and WRENAB are used for output modules.
Jumper J1 connects the SIG COM shield wires (pins 2, 5, and 6) to the
backpanel signal ground. This provides a ground connection between the
host system and backpanel. Jumper J1 is required if output modules are
used, or if there is no high impedance sense input (input low of a differential
or pseudo-differential system) on the host measurement system.
Jumper J2 connects the SNS LO line (pin 4) to the backpanel signal ground.
If the host system has the capability, this allows measuring the OM5-BP-16-
MUX-C ground potential.
ADDRESS SELECTION
The OM5-BP-16-MUX-C backpanel has address decoding circuitry to allow
multiplexinganycombinationofupto16inputoroutputmodules. Capability
is also provided in the address decode circuitry to expand the system to 64
channels (four OM5-BP-16-MUX-C backpanels) of multiplexed input or
output. Jumpers on HD10 header, E1 and E2 group, select which set of 16
addresses are assigned to a particular backpanel. The E1 group assigns a set
of 16 addresses for input modules, and the E2 group assigns a set of 16
addresses for output modules. The table below shows the correlation of
jumper position to address range.
For proper operation of the output switch or track-and-hold circuit when
usingtheOM5-BP-16backpanels, acurrentpathmustexistbetweenthehost
controllogicpowercommonandmoduleI/OCommon(modulepin19). This
path can be established on the OM5-BP-16-MUX-C via jumper J4. If this
connection exists elsewhere in the system, jumper J4 should be removed
sincepossiblegroundloopscouldexist. Otherconnectionsofpowerground
and signal ground usually occur at the A/D or D/A converter of the host
measurement system.
E1 Jumper Pos
E2 Jumper Pos
Address Range/Mode
If the connection of power common and SIG COM shield wires exist in the
host measurement system, a resistive connection between SIG COM and the
backpanel signal ground can be made via R1. R1 can be aslargeas 10K ohms;
100 ohms is a recommended value. Jumper J3 can be used to connect the
SNS LO line to R1 when this ground configuration is used.
4
3
2
1
0
4
3
2
1
0
0-15, STAND ALONE
48-63, EXPANDED
32-47, EXPANDED
16-31, EXPANDED
0-15, EXPANDED
Forfullprotectionagainstlargeelectricaldisturbancesonthefield-sideofthe
OM5 modules, a #10-32 ground stud is provided on the backpanel. An
electricalconnectionbetweenthisgroundstudandsystemgroundshouldbe
provided with a large gauge wire of the shortest possible length. When this
connection is made, a possible ground loop could result through the SIG
COM shield wires and backpanel signal ground. If the application involves
only input modules and a differential input is used by the host measurement
system, J1 should be removed. Remember that J1 is required if output
modules are used or if the host system does not have differential inputs.
To connect multiple OM5-BP-16-MUX-C backpanels in this expanded
configuration, use interconnect cable OM5-CAB-01-C.
POWER
The OM5-BP-16-MUX-C backpanel requires external +5VDC 5% power.
The chassis mounted OMX-976 power supplies have adequate capacity to
power any combination of modules.
FUSING
The OM5-BP-16-MUX-C backpanel power is fuse protected through F1.
This is a Littlefuse type 252004, 4 amp fuse. Zener diode DZ1 provides extra
protection by clamping the input power voltage to +5.6V. If the input supply
voltage connection is reversed, this zener diode will be forward biased and
fuse F1 will be blown.
P1
OM5 Module
2
5
6
4
SIG COM
SIG COM
SIG COM
SIG COM
I/O COM 19
16 PWR COM
J2
J1
J4
J3
Power Common
Signal Ground
R
1
and
Grounding Bolt
FIGURE 7. OM5-BP-16-MUX-C Grounding Diagram.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-SKT-C /-2-C ONE / TWO POSITION ANALOG I/O BACKPANELS
DESCRIPTION
SPECIFICATIONS
Operating Temperature:
–40°C to +85°C
The OM5-BP-SKT-C is a single channel mounting panel for the OM5
modules. The OM5-BP-2-C is a dual channel mounting panel for the OM5
modules. They both are DIN rail compatible.
95% relative humidity, non-condensing
Interface Connector:
Field
Logic
High Density Screw Clamp, 14 AWG Max
High Density Screw Clamp, 14 AWG Max
See Figures 9 and 10 for wiring diagrams, Figures 11 and 12 for schematics.
The following accessories are required for mounting one OM5-BP-SKT- or
-2-C panel (Figure 8):
Qty
Model
Description
1
2
OM7-DIN-SF
OM7-DIN-SE
Base element with snap foot
Side element
The following accessories are required for mounting two or more OM5-BP-
SKT- or -2-C panels:
DIN Rail
mounts to DIN rails
EN 50022-35x7.5
EN 50022-35x15
EN 50035-G32
Qty
Model
Description
2
2
OM7-DIN-SF
OM7-DIN-SE
Base element with snap foot
Side element
(# panels)-2
(4 x (# panels))-4 OM7-DIN-CP
OM7-DIN-WSF Base element without snap foot
Connection pins
OM7-DIN-SE
OM7-DIN-SF
OM7-DIN-CP
OM7-DIN-WSF
The following DIN rail styles are available. Specify length in meters (-XX)
EN 50022-35x7.5 (slotted steel)
EN 50035-G32 (slotted steel)
EN 50022-35x15 (slotted steel)
OM7-DIN-SE
FIGURE 8. DIN Rail Mounting Elements.
Sockets for Current Conversion Resistor, OMX-1362-C
OMX-CJC-C Cold Junction
Compensation Circuit
J1
–EXC
–In/–Out
Power Common
+5V
+In/+Out
+EXC
I/O COM/–IIN
VIN/VOUT/+IIN
TB1
TB2
Isolated I/O
Local I/O
4.25"
(108mm)
FIGURE 9. OM5-BP03-C Wiring Diagram.
Sockets for Current Conversion Resistor, OMX-1362-C
OMX-CJC-C Cold Junction
Compensation Circuit
TB1
TB3
3
4
1
2
Power Common
+5V
Channel A
I/O COM/–IIN
VIN/VOUT /+IIN CH A
V
IN/VOUT /+IIN CH B
Channel B
1
2
3
4
Local I/O
TB2
TB4
Isolated I/O
4.25"
(108mm)
FIGURE 10. OM5-BP04-C Wiring Diagram.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
I/O VIN
/
COM/ VOUT/
–IIN +IIN
PCOM +5V
TB2
4
3
2
1
J1
LED
WR EN\ 23
DATA 21
I/O COM 19
22 RD EN\
20 VOUT
18 VIN
17
+5V
16 PCOM
6
4
2
+In
+EXC
+SEN
–In
–EXC
–SEN
5
3
1
OMX-CJC-C
OMX-1362-C
TB1
1
2
3
4
–EXC –In/ +In/ +EXC
–Out +Out
VIN
/
VIN/
VOUT/ VOUT
/
I/O
COM/
–IIN
–IIN –IIN
CH A CH B
FIGURE 11. OM5-BP-SKT-C Schematic.
PCOM +5V
TB3
2
1
TB4
3
2
1
J2
LED
WR EN\ 23
DATA 21
I/O COM 19
WR EN\ 23
DATA 21
I/O COM 19
+5V17
22 RD EN\
20 VOUT
18 VIN
22 RD EN\
20 VOUT
18 VIN
17
+5V
16 PCOM
16 PCOM
6
4
2
+In
+EXC
+SEN
6
4
2
+In
+EXC
+SEN
–In
–EXC
–SEN
5
3
1
–In
–EXC
–SEN
5
3
1
OMX-CJC-C
OMX-CJC-C
OMX-1362-C
OMX-1362-C
*NOTE: OMX-1362-C resistors are
not installed at factory.
TB1
1
2
3
4
TB2
1
2
3
4
–EXC –In/ +In +EXC
–Out +Out
–EXC –In +In +EXC
–Out +Out
Channel A
Channel B
FIGURE 12. OM5-BP-2-C Schematic.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-8-C 8 POSITION ANALOG I/O BACKPANEL, NON-MULTIPLEXED
A temperature sensor is mounted on each channel to provide cold junction
compensationforthermocoupleinputmodules(SeeFigure14forSchematic-
DESCRIPTION
The OM5-BP-8-C analog module mounting board has a capacity of eight
analog input and/or output modules in any combination. It can be mounted
on the OMX-1363-C 19-inch metal rack. A separate analog signal path is
provided for each channel and each channel’s signal is accessible at
redundant 26-pin connectors. The module output switch is continuously
“on” when using this backpanel and all eight module outputs are simulta-
neously accessible to high-speed data acquistion (ADC) boards.
SPECIFICATIONS
On-board jumpers permit paralleling two OM5-BP-8-C boards to form a
OM5-BP-16-C equivalent. An additional set of inter-channel bridge jumpers
permits connecting an input module’s output to an output module’s input,
providing two levels of isolation (Figures 13, 14).
Operating Temperature:
–40°C to +85°C
95% relative humidity, non-condensing
Interface Connector:
Field
Logic
High Density Screw Clamp, 14 AWG Max
26-pin, male header connector
Jumpers on the OM5-BP-8-C permit user selection of low (i.e. channels 0-
7) or high (i.e. channels 8-15) addresses.
10.0"
Tolerance: 0.020" ( 0.50mm)
(254.0mm)
9.7"
(246.3mm)
9.5"
(241.3mm)
26 Conductor
Male Pin
5.8"
(147.3mm)
Connectors P1, P2(1)
0.15"
(3.8mm)
10.32 X 0.40
Ground Lug, Including
Nut and Lockwasher
L H
J12
P1 P2
JP7
JP1
Swaged
Standoff
Thru Hole
0.15" (3.8mm) Dia.
(6)
J5
J4
J1 J2 J3
OMX-CJC-C
Cold Junction
Compensation Circuit
0.75"
(19.1mm)
+5VDC Supply
Pin 2
Sockets for Current
Conversion Resistors, OMX-1362-C
Barrier Strips for
Field Analog Signal
I/O Termination. (8)
Pin 1
Pin 2
Pin 1
2.25"
(57.2mm)
3.15"
(80.2mm)
NOTES: (1) Connector is Berg 65863-075 or equivalent.
Mating connector is AMP 49958-6 or equivalent.
Connectors P1 and P2 are wired in parallel for
“Daisy Chaining” up to 8 boards.
FIGURE 13. OM5-BP-8-C Analog I/O Backpanel.
ELECTRICAL
ADDRESS SELECTION
ADJACENT CHANNEL JUMPERS
Module addresses may be selected as low (channels 0-7) or high (channels Adjacent channels may be connected together to provide an isolated output
8-15) using the sets of 3 pins labeled J5 through J12. Place a jumper over signal from an isolated input module, providing two levels of 1500V
thetwopinsclosesttotheribboncableconnectors, P1andP2, toselectalow isolation. This capability is provided with the seven jumpers labeled JP1–
address (factory configuration) or over the two pins furthest from the ribbon JP7.
cable connectors, P1 and P2, to select a high address.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE14.OM5-BP-8-CSchematic.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-8-MUX-C 8 POSITION ANALOG I/O BACKPANEL, MULTIPLEXED
DESCRIPTION
SPECIFICATIONS
Operating Temperature:
–40°C to +85°C
The OM5-BP-8-MUX-C backpanel (Figure 15) can accept up to eight OM5
modulesinanycombination. ItcanbemountedontheOMX-1363-C19-inch
metal rack. The OM5-BP-8-MUX-C has two analog buses; one for analog
input and one for analog output. This two-bus configuration takes advantage
of the switch controlled outputs on the input modules and the track-and-hold
inputs on the output modules. A temperature sensor is mounted on each
channel to provide cold junction compensation for thermocouple input
modules (See Figure 16 for schematic). Field connections are terminated
with four screw terminals at each module site. Up to eight OM5-BP-8-MUX-
C backpanels may be daisy-chained. Use OMX-CAB-01-C cable for daisy
chaining and OMX-1315-xx-C cable for connecting to host computer.
95% relative humidity, non-condensing
Interface Connector:
Field
Logic
High Density Screw Clamp, 14 AWG Max
26-pin, male header connector
Address Input Logic Levels:
Max Logic “0”
0.8V
2.0V
Min Logic “1”
II Input Current, “0” or “1”
0.1µA max at 25°C
1.0µA max –25°C to +85°C
Jumpers on the OM5-BP-8-MUX-C permit user selection of low (i.e.
channels 0-7) or high (i.e. channels 8-15) addresses.
RD EN\ or WR EN\ Signal Delay
from Connector P1 to Channels 0-7
Standalone (address 0-7)
51ns at 25°C
64ns at –25°C to +85°C
100ns at 25°C
126ns at –25°C to +85°C
Expanded (address 8-63)
10.0"
(254.0mm)
Tolerance: 0.020" ( 0.50mm)
9.7"
(246.3mm)
9.5"
(241.3mm)
5.8"
(147.3mm)
26 Conductor
Male Pin Connector P1(1)
0.15"
(3.8mm)
P2
1
P3
6
J7
10.32 X 0.40
Ground Lug, Including
Nut and Lockwasher
P1
J8
J6
L
H
J5
J4
Swaged
Standoff
L
H
J1 J2 J3
Thru Hole
0.15" (3.8mm) Dia.
(6)
OMX-CJC-C
Cold Junction
Compensation Circuit
0.75"
(19.1mm)
Pin 2
Pin 1
+5VDC Supply
Sockets for Current
Conversion Resistors, OMX-1362-C
Barrier Strips for
Field Analog Signal
I/O Termination. (8)
Read Address
Selection Jumper
2.25"
(57.2mm)
Write Address
Selection Jumper
NOTES: (1) Connector is Berg 65863-075 or equivalent.
Mating connector is AMP 49958-6 or equivalent.
3.15"
(80.2mm)
FIGURE 15. OM5-BP-8-MUX-C Analog I/O Backpanel.
backpanel. The Read Address group assigns a set of 16 addresses for input
modules, and the Write Address group assigns a set of 16 addresses for
output modules. The table below shows the correlation of jumper position to
address range.
ELECTRICAL
ADDRESS SELECTION
Module read and write addresses may be selected as low (channels 0-7) or
high (channels 8-15) using the four sets of 3 position jumpers labeled J5
through J8. Place a jumper over the two pins furthest from the field I/O
termination blocks on all four sets to select a low address (factory configu-
ration) or over the two pins closest to the field I/O termination blocks on all
four sets to select a high address.
Address Selection Jumpers
Read Address
Jumper(P2)
Write Address
Jumper(P3)
Address
Range
1
2
3
4
5
6
7
8
9
10
0-15 Stand alone
48-63 Expanded
32-47 Expanded
16-31 Expanded
0-15 Expanded
The OM5-BP-8-MUX-C backpanel has address decoding circuitry to allow
multiplexing any combination of up to 8 input or output modules. Capability
is also provided in the address decode circuitry to expand the system to 64
channels (eight OM5-BP-8-MUX-C backpanels) of multiplexed input or
output. Jumpers select which set of 16 addresses are assigned to a particular
45
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 16. OM5-BP-8-MUX-C Schematic.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-16-DIN-C, OM5-BP-16-MUX-DIN-C, OM5-BP-8-DIN-C,
OM5-BP-8-MUX-DIN-C
SCMXSE DIN rail mounting elements. The SCMPB0X-2 comes fully as-
sembled.
DESCRIPTION
The SCMPB0X-2 is the SCMPB0X backpanel with a DIN rail mounting
option. The SCMPB0X backpanel is attached to a 0.062" thick piece of black
anodized aluminum, which in turn is captured using the SCMXBEFE and
OMX-1363-C 19 INCH METAL MOUNTING RACK
DESCRIPTION
The OMX-1363-C is a 19-inch metal rack for mounting the OM5-BP backpanels. It also provides capability to mount the PMX-976-C power supplies, and
the OMX-1324-C interface board (See Figure 17 for dimensions).
17.60" (447.04mm)
3.62" (91.95mm)
3.12" (79.25mm)
0.31" (7.87mm)
1.375" (34.93mm) 2 PL
0.125" (3.17mm) 2 PL
0.062" (1.57mm)
0
0.63" 0
(16.00mm)
17.29" 18.23"
(439.16mm) (463.04mm)
Cable Access Cutout
Left Side Only
3.480" (88.39mm)
3.378" (85.80mm)
3.103" (78.82mm)
3.265
(82.93mm)
3.00"
(76.2mm)
0.141" (3.58mm) Dia 8 PL
3mm metric
PEM nut 7 PL
0.50"
(12.7mm)
0.378" (9.60mm)
0.103" (2.62mm)
0
0.215"
(5.46mm)
0
0
1.10"
2.60"
(27.94mm) (66.04mm)
FIGURE 17. OMX-1363-C Analog Rack Dimensions.
OMX-1324-C UNIVERSAL INTERFACE BOARD
DESCRIPTION
The OMX-1324-C is a universal interface board which converts a 26-pin ribbon cable input to 26 screw terminals for discrete wire. It can be mounted on
the back of the OMX-1363-C mounting rack or on a DIN rail. Required mounting hardware is included. Use OMX-1315-xx-C cable (See Figure 18 for
dimensions).
4.00"
(101.6mm)
2
4
6
8
10 12 14 16 18 20 22 24 26
2
2.20"
(55.9mm)
1
1
3
5
7
9
11 13 15 17 19 21 23 25
1.90"
(48.3mm)
FIGURE 18. OMX-1324-C Universal Interface Board Dimensions.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-BP-SKT-C ANALOG MODULE EVALUATION BOARD
DESCRIPTION
2.85"
The OM5-BP-SKT-C is a single channel board with a test socket for OM5
module evaluation (Figure 19). All signal input/output, control, and power
connections are connected to terminal blocks for ease of user access. A cold
junction temperature sensor circuit is included for evaluation of thermo-
couple modules. (See Figure 20 for schematic).
(72.4mm)
0.25" (6.4mm) Typical
0.25"
(6.4mm)
Typical
Control
Local I/O
RD EN\
VOUT
The OM5-BP-SKT-C is mechanically compatible with DIN rail mounting
using the following elements:
WR EN\
Reserved
PCOM
I/O COM
VIN
2 OM7-DIN-SF base elements with snap foot
2 OM7-DIN-SE side elements
4 OM7-DIN-CP connection pins
I/O COM
TB1
TB3
TB2
J1
+5V
4.25"
(108mm)
PCOM
+
Two jumpers are provided for customer use. The first, J1, provides a current
path between +5V Power Common (module pin 16) and I/O Common
(module pin 19). A path must exist between the host control logic power
common and module I/O Common for proper operation of the module output
switch or track-and-hold circuit. If this connection exists elsewhere in the
system, jumper J1 should be removed since possible ground loops could
exist. Other connections of power ground and signal ground usually occur
at the A/D or D/A converter of the host measurement system.
CJC
–
J2
OMX-1362-C
OMX-CJC-C
TB4
Jumper J2 is used in the cold junction compensation circuit. If it is installed,
the compensation circuit is enabled and will provide the proper compensa-
tion voltage to correct for the thermoelectric effect at the +In and –In screw
terminals. If an external simulation voltage is desired for cold junction
compensation, J2 should be removed. The external voltage is applied at the
socketslabledCJC+andCJC–.Anexternalvoltageof510.0mVcorresponds
to an ambient temperature of +25 °C. The transfer function of the onboard
compensation circuit is VCJC = 0.510 –0.0025(T–25)V.
–EXC
–In
+EXC
+In
FIGURE 19. OM5-BP-SKT-C Evaluation Board Dimensions And Pin Layout.
23
21
19
17
TB1
RD EN\
WR EN\
Reserved
PCOM
TB2
22
20
18
16
VOUT
I/O COM
VIN
I/O COM
OM5
PCOM
I/O COM
6 +In
4 +EXC
2 +SEN
PCOM
–In 5
–EXC 3
–SEN 1
J1
+5
PCOM
I/O COM
TB3
J2
+
CJC
–
PCOM
DZ1
LED
OMX-CJC-C
PCOM
OMX-1362-C
NOTES:
1. J1 and J2 are factory installed.
2. SCMXCJC is a CJC temperature sensor.
3. Resistor SCMXR1 is an optional I/V conversion
resistor for current inputs, not factory installed.
TB4
–EXC –In +In +EXC
FIGURE 20. OM5-BP-SKT-C Evaluation Board Schematic.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-1315-XX-C, OMX-CAB-01-C INTERFACE CABLES
DESCRIPTION
OM5-1315-XX-C
OMX-CAB-01-C
System interface cable for the SCMPB01/02/05/06 backpanels. This is a 26
conductorribboncablewithamass-terminatedsocketconnectorinstalledon
each end. It can be ordered in any length; -xx denotes required length in
meters (Figure 21).
Daisy-chain cable provides interconnection between a maximum of four
OM5-BP-16-MUX-C and eight OM5-BP-8-MUX-C backpanels (See Figure
22).
Colored Stripe on
Cable is Assembled to
Pin 1 of Connectors
Colored Stripe on
Cable is Assembled to
Pin 1 of Connectors
Socket
Connector
Socket
Connector
Socket
Connector
Socket
Connector
Pin Connector
Pin 1
Pin 1
Cable
Pin 1
Cable
Pin 1
Pin 1
–XX, Lenglth in Meters
1 Meter (3.3 feet)
FIGURE 21. OMX-1315-XX-C System Interface Cable.
FIGURE 22. OMX-CAB-01-C Daisy-Chain Cable.
OMX-CAB-01-C
OM5-BP-8 or 16-MUX-C
OM5-BP-8 or 16-MUX-C
OM5-BP-8 or 16-MUX-C
OMX-CAB-01-C
OMX-CAB-01-C
OM5-BP-8 or 16-MUX-C
TO HOST
SYSTEM
OMX-1315-XX-C
Up to eight OM5-BP-8-MUX-C backpanels
FIGURE 23. Application Of OMX-CAB-01-C Daisy-Chain Cable.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
OMX-CJC-C ENCAPSULATED COLD JUNCTION COMPENSATION
0.60"
(15.2mm)
0.30"
(7.6mm)
DESCRIPTION
The OMX-CJC-C is the identical circuit used on the OM5-BP backpanels
except it is packaged as a component for use in customer designed mounting
boards(Figure24).WheninterfacedtoanOM5-ITCorOM5-LTCmodule,the
transferfunctionofthevoltageacrossthe+SENand–SENpinsisVCJC =0.510
–0.0025(T –25)V.
0.50"
(12.7mm)
Side
Side
0.10" – 0.15"
(2.5 – 3.8mm)
0.15" (3.8mm)
0.03" (0.76mm)
0.35" (8.9mm)
0.45" (11.4mm)
SPECIFICATIONS
Accuracy +25°C
+5°C to +45°C
–40°C to +85°C
0.25°C
0.5°C
1.25°C
Pin Width = 0.020" (0.51mm)
(Recommended PCB
hole size of 0.031")
–EXC
–SEN +SEN
Bottom
FIGURE 24. OMX-CJC-C Physical Dimensions And Pin Layout.
OMX-1344 JUMPERS
DESCRIPTION
Package of 10 jumpers for connecting adjacent input/output modules on the OM5-BP-16-C backpanel. This connection is made if it is desired to direct
the output of any input module to the input of an adjacent output module. The jumpers can also be used for configuring I/O addresses on the OM5-BP-
16-MUX-C backpanel.
OMX1362-C CURRENT CONVERSION RESISTOR
0.50"
(12.7mm)
0.15"
(3.8mm)
DESCRIPTION
A precision 20Ω, 0.1%, 10ppm/°C resistor used with the OM5-II current
input module or OM5-TX two-wire transmitter interface module (Figure 25).
Sockets are provided on all backpanels to allow installation of this resistor.
One OMX-1362-C is shipped with each module.
0.50"
(12.7mm)
Side
Side
0.075"
(1.9mm)
0.05" (1.3mm)
0.45" (10.2mm)
Pin Width = 0.040" (1.02mm)
Bottom
FIGURE 25. OMX-1362-C Physical Dimensions.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
OMX-955-C, OMX-955-220-C POWER SUPPLIES
DESCRIPTION
The OMX-955-C encapsulated power supplies are available in 120VAC or
220VAC input voltage ranges and provide 5VDC outputs suitable for all OM5
modules. They are designed to mount on the OMX-1363-C metal rack. The
supplies are UL-recognized and CSA certified. Their compact size and low
weight are ideal for high-density applications (see Figure 25.)
SPECIFICATIONS
OMX-955-C
OMX-955-220-C
Input Voltage Range
Output Voltage
Output Current, +50°C
(derate 2.5%/°C above +50°C)
Operating Temp
Dielectric Withstand Voltage (Input to Ground)
Line Regulation
105-125VAC
5VDC
200-240VAC
5VDC
1A
1A
-25°C to +71°C
2500VRMS
0.05%
-25°C to +71°C
2500VRMS
0.05%
Load Regulation
Output Ripple, max
0.15%
2mVRMS
0.15%
2mVRMS
Overvoltage Protection, nominal
Weight
6.2V
6.2V
1.25 lbs (567 grams)
1.25 lbs (567 grams)
Supplies are UL recognized, File No. E65890, and CSA certified, File No. LR59996.
0.75"
(19.1mm)
5.40 BH
Screws
0.75"
(19.1mm)
AC
AC
NC
2.50"
4.00"
NC
Inserts
4.40 Thread
(63.5mm) (101.6mm)
.125" (3.2mm) deep
COM
+OUT
1.45" (36.8mm)
2.00" (50.8mm)
2.70" (68.6mm)
0.35"
(8.9mm)
FIGURE 25. OMX-955/955-220-C Physical Dimensions.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
OMX-977-C, OMX-977-220-C POWER SUPPLIES
DESCRIPTION
The OMX-977 Linear Power Supplies are available in 120VAC or 220VAC
input. Theyhavesufficientoutputcurrentcapacitytosupplyanycombination
ofOM5modules. TheOMX-1363-Cmetalrackprovidesmountingcapability
for the power supplies (See Figure 26).
SPECIFICATIONS
OMX-977-C
OMX-977-220-C
Input Voltage Range
Output Voltage
104-132VAC
5VDC 1%
3A
207-265VAC
5VDC 1%
3A
Output Current (at +70°C)
Output Current (at +50°C)
Operating Temp
Dielectric Withstand Voltage (input to ground)
Line Regulation (10% line change)
Load Regulation (50% load change)
Output Ripple (max)
6A
6A
0 to +70°C
3750VAC
0.05%
0.05%
5 mVP-P
0 to +70°C
3750VAC
0.05%
0.05%
5 mVP-P
Overvoltage Protection (factory set)
6.2 V 0.4V
6.2 V 0.4V
Both supplies are tested and certified by TUV to VDE 0806 and IEC 380. They are UL Recognized (File Number E55974) and CSA Certified
(CSA File Number LR38879).
0.50"
(12.7mm)
0.15"
(3.8mm)
0.50"
(12.7mm)
Side
Side
0.075"
(1.9mm)
0.05" (1.3mm)
0.45" (10.2mm)
Pin Width = 0.040" (1.02mm)
Bottom
FIGURE 26. OMX-977/977-220-C Physical Dimensions.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTION GUIDE FOR OM5 ISOLATED
SIGNAL CONDITIONING PRODUCTS
General Description
ANALOG VOLTAGE INPUT MODULES, NARROW BANDWIDTH (4Hz BW)
OMEGA® OM5 Series Isolated Signal Conditioning Modules are low cost,
high performance, plug-in signal conditioners. Each OM5 module provides
a single channel of isolated analog input or output. Input modules interface
to all types of external sensors. The modules filter, isolate, amplify, and
convert the input signal to a high-level analog voltage output. The output
modules accept a high-level analog voltage signal from a host system, then
buffer, isolate, and amplify before providing a process current or voltage
output to field devices. Over 115 different OM5 modules are available
encompassingawideselectionofisolatedanaloginputandoutputfunctions.
Analog inputs include voltage and current in narrow and wide bandwidths,
Thermocouple, RTD, Potentiometer, Strain Gage, Frequency, and 2-Wire
Transmitter. Custom I/O ranges are also available. All modules are CSA
certified and FM approved for safe operation in Class I, Division 2, Groups
A, B, C, and D hazardous environments.
MODEL INPUT RANGE
OUTPUT RANGE*
OM5-IMV-10A-C 10mV
OM5-IMV-50A-C 50mV
OM5-IMV-100A-C 100mV
OM5-IMV-10B-C 10mV
OM5-IMV-50B-C 50mV
OM5-IMV-100B-C 100mV
5V
5V
5V
0 to +5V
0 to +5V
0 to +5V
OM5-IV-1A-C
OM5-IV-5A-C
OM5-IV-10A-C
OM5-IV-1B-C
OM5-IV-5B-C
OM5-IV-10B-C
OM5-IV-20A-C
OM5-IV-20B-C
OM5-IV-40A-C
OM5-IV-40B-C
1V
5V
5V
5V
10V
1V
5V
10V
20V
20V
40V
40V
5V
0 to +5V
0 to +5V
0 to +5V
5V
0 to +5V
5V
0 to +5V
ANALOG CURRENT INPUT MODULES, 4Hz AND 1kHz BANDWIDTH
MODEL
INPUT RANGE
OUTPUT RANGE*
BW
Accessories include: addressable and non-addressable single, dual, eight
and 16 channel backpanels, available with on-board temperature sensors
and cold junction thermocouple compensation; power supplies; mounting
racks; interface cables, and evaluation boards.
OM5-II-4/20-C
OM5-II-0/20-C
4 to 20mA
0 to 20mA
0 to +5V
0 to +5V
4Hz
4Hz
TRUE RMS INPUT MODULES
MODEL
INPUT RANGE (rms)
OUTPUT RANGE (dc)
OM5-IAC-100B-C
OM5-IAC-1B-C
OM5-IAC-10B-C
0 to 100mV
0 to 1V
0 to 10V
0 to +5V
0 to +5V
0 to +5V
OM5 modules offer several advantages when compared with competitive
parts, while maintaining equivalent price:
LINEARIZED 2- OR 3-WIRE RTD INPUT MODULES (0 to +5V OUTPUT*,
4Hz BW)
• 50 times better noise rejection by using a 6-pole filter with 95dB
NMR, versus a three-pole filter with 60dB NMR; • Lower output noise
• True 3-way isolation • CMR of noise spikes measures 20dB better
than competing models.
MODEL
TYPE***
INPUT RANGE
OM5-IP-N100-C
OM5-IP-100-C
OM5-IP-200-C
OM5-IP-600-C
100Ω Pt
100Ω Pt
100Ω Pt
100Ω Pt
–100°C to +100°C (–148°F to +212°F)
0°C to +100°C (+32°F to +212°F)
0°C to +200°C (+32°F to +392°F)
0°C to +600°C (+32°F to +1112°F)
Key Specifications
• 1500V Isolation
OM5-IC-120-01-C 10Ω Cu at 0°C
0°C to +120°C (+32°F to +248°F)
OM5-IC-120-02-C 10Ω Cu at 25°C 0°C to +120°C (+32°F to +248°F)
OM5-IN-300-C
120Ω Ni
0°C to +300°C (+32°F to +572°F)
• Accuracy, 0.05%
• CMR, 160dB
• NMR, 95dB
• Transient Protection, ANSI/IEEE C37.90.1-1989
LINEARIZED 4-WIRE RTD INPUT MODULES (0 to +5V OUTPUT*, 4Hz BW)
MODEL
TYPE***
INPUT RANGE
OM5-IP4-N100-C 100Ω Pt
–100°C to +100°C (–148°F to +212°F)
0°C to +100°C (+32°F to +212°F)
0°C to +200°C (+32°F to +392°F)
0°C to +600°C (+32°F to +1112°F)
0°C to +120°C (+32°F to +248°F)
OM5-IP4-100-C
OM5-IP4-200-C
OM5-IP4-600-C
100Ω Pt
100Ω Pt
100Ω Pt
OM5-IC4-120-01-C 10Ω Cu at 0°C
•
1µV/°C Drift
OM5-IC4-120-02-C 10Ω Cu at 25°C 0°C to +120°C (+32°F to +248°F)
OM5-IN4-300-C 120Ω Ni 0°C to +300°C (+32°F to +572°F)
• Output noise as low as 150µVrms
• 240VAC Protection for field I/O
• Operating temp range, –40°C/+85°C
• CSA CERTIFIED (Class
• FM APPROVED (Class
POTENTIOMETER INPUT MODULES (4Hz BW)
MODEL INPUT RANGE OUTPUT RANGE*
OM5-PT-100-C 0 to 100Ω
0 to +5V
0 to +5V
0 to +5V
0 to +5V
OM5-PT-500-C 0 to 500Ω
I
, Division 2, Groups A, B, C, D)
OM5-PT-1K-C
0 to 1KΩ
I, Division 2, Groups A, B, C, D)
OM5-PT-10K-C 0 to 10KΩ
THERMOCOUPLE INPUT MODULES (0 to +5V OUTPUT*, 4Hz BW)
• EUROPEAN EMC DIRECTIVE COMPLIANT
• CE APPROVAL for low voltage directive not applicable.
Products comply with ENG1010-1 (IEC1010)
MODEL
TYPE**
INPUT RANGE
OM5-ITC-J-C
OM5-ITC-K-C
OM5-ITC-T-C
OM5-ITC-E-C
OM5-ITC-R-C
OM5-ITC-S-C
OM5-ITC-B-C
OM5-ITC-C1-C
OM5-ITC-N1-C
J
–100°C to +760°C (–148°F to +1400°F)
–100°C to +1350°C (–148°F to +2462°F)
–100°C to +400°C (–148°F to +752°F)
0°C to +900°C (+32°F to +1652°F)
0°C to +1750°C (+32°F to +3182°F)
0°C to +1750°C (+32°F to +3182°F)
0°C to +1800°C (+32°F to +3272°F)
+350°C to +1300°C (+662°F to +2372°F)
-100°C to +1300°C (-148°F to +2372°F)
K
T
E
R
S
B
C
N
Applications
• DESIGNED FOR INDUSTRIAL PLANT ENVIRONMENTS
• PROTECTS USER EQUIPMENT FROM LIGHTNING AND HEAVY
EQUIPMENT POWER-LINE VOLTAGE
• REDUCES ELECTRICAL NOISE IN MEASURED SIGNALS
• CONVENIENT SYSTEM EXPANSION AND REPAIR
STRAIN GAGE INPUT MODULES ( 5V OUTPUT*, 10kHz BW)
MODEL INPUT
EXCITATION
OM5-WBS38-01-C 10mV Full Bridge Input, (3mV/V) 100 to 10kΩ
OM5-WBS-1-C 30mV Full Bridge Input, (3mV/V) 300 to 10KΩ
3.333V
10.000V
3.333V
OM5-WBS38-03-C 10mV Half Bridge Input, (3mV/V) 100 to 10kΩ
OM5-WBS-3-C
OM5-WBS-2-C
OM5-WBS-4-C
OM5-WBS-5-C
30mV Half Bridge Input, (3mV/V) 300 to 10KΩ
10.000V
10.000V
20mV Full Bridge Input, (2mV/V) 300 to 10KΩ
33.3mV Full Bridge Input, (10mV/V) 100 to 10KΩ 3.333V
100mV Full Bridge Input, (10mV/V) 300 to 10KΩ 10.000V
ANALOG CURRENT OUTPUT MODULES, 400Hz AND 1kHz BANDWIDTH
MODEL
INPUT RANGE
OUTPUT RANGE
BW
OM5-IVI-B4-C
OM5-IVI-A4-C
OM5-IVI-B0-C
OM5-IVI-A0-C
0 to +5V
5V
0 to +5V
5V
4 to 20mA
4 to 20mA
0 to 20mA
0 to 20mA
400Hz
400Hz
400Hz
400Hz
2
Download from Www.Somanuals.com. All Manuals Search And Download.
SELECTION GUIDE FOR OM5 ISOLATED SIGNAL CONDITIONING PRODUCTS
ANALOG VOLTAGE INPUT MODULES, WIDE BANDWIDTH (10kHz BW)
VOLTAGE OUTPUT MODULES, 50mA DRIVE CAPACITY (400 Hz BW)
MODEL
INPUT RANGE
OUTPUT RANGE*
MODEL INPUT RANGE
OUTPUT RANGE
OM5-WMV-10A-C 10mV
OM5-WMV-50A-C 50mV
OM5-WMV-100A-C 100mV
OM5-WMV-10B-C 10mV
OM5-WMV-50B-C 50mV
OM5-WMV-100B-C 100mV
5V
OM5-AV-1-C
OM5-AV-2-C
OM5-AV-3-C
OM5-AV-4-C
OM5-AV-5-C
OM5-AV-6-C
OM5-AV-7-C
0 to +5V
5V
5V
5
5V
5V
5V
0 to +5V
10V
0 to +5V
0 to +5V
0 to +5V
0 to +10V
10V
10V
5V
10V
0 to +10V
10V
OM5-WV-1A-C
OM5-WV-5A-C
OM5-WV-10A-C
OM5-WV-1B-C
OM5-WV-5B-C
OM5-WV-10B-C
OM5-WV-20A-C
OM5-WV-20B-C
OM5-WV-40A-C
OM5-WV-40B-C
1V
5V
5V
5V
ACCESSORIES
MODEL
10V
1V
5V
10V
20V
20V
40V
40V
5V
DESCRIPTION
0 to +5V
0 to +5V
0 to +5V
5V
OM5-BP-16-C
OM5-BP-16-DIN-C
OM5-BP-16-MUX-C
Non-multiplexed, 16 channel backpanel
OM5-BP-16-C with DIN rail mounting option
Multiplexed, 16 channel backpanel
OM5-BP-16-MUX-DIN-C OM5-BP-16-MUX-C with DIN rail mounting option
0 to +5V
5V
0 to +5V
OM5-BP-8-C
OM5-BP-8-DIN-C
OM5-BP-8-MUX-C
Non-multiplexed, 8 channel backpanel
OM5-BP-8-C with DIN rail mounting option
Multiplexed, 8 channel backpanel
2-WIRE TRANSMITTER INTERFACE MODULES (100Hz BW)
OM5-BP-8-MUX-DIN-C OM5-BP-8-MUX-C with DIN rail mounting option
MODEL
INPUT RANGE OUTPUT RANGE
OM5-BP-SKT-C
OM5-BP-2-C
Single channel backpanel, DIN rail mount
Dual channel backpanel, DIN rail mount
Base element without snap foot
Base element with snap foot
System interface cable for analog backpanels
xx = length in meters
Daisy chain cable for OM5-BP-16-MUX-C
Ribbon cable to screw interface board
Package of 10 jumpers
OM5-TX-1-C
OM5-TX-2-C
4 to 20mA
4 to 20mA
+1 to +5V
+2 to +10V
OM7-DIN-WSF
OM7-DIN-SF
GENERAL PURPOSE INPUT MODULES, DC EXCITATION
MODEL MAXIMUM INPUT
OMX-1315-xx-C
OUTPUT*
OMX-CAB-01-C
OMX-1324-C
OMX-1344-C
OMX-955-C
OM5-DT-1-C
OM5-DT-2-C
OM5-DT-3-C
OM5-DT-4-C
OM5-DT-5-C
OM5-DT-6-C
OM5-DT-7-C
OM5-DT-8-C
OM5-DT-9-C
OM5-DT-10-C
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
5V
5V
5V
5V
5V
5V
5V
5V
5V
5V
Power supply, 1A, 5VDC, 120VAC U.S.
Power supply, 3A, 5VDC, 120VAC U.S.
Power supply, 3A, 5VDC, 220VAC U.S.
Precision 20Ω resistor for OM5-II and OM5-TX
Encapsulated cold junction circuit
19 inch metal rack for mounting backpanels
Side element
OMX-977-C
OMX-977-220-C
OMX-1362-C
OMX-CJC-C
OMX-1363-C
OM7-DIN-SE
OM7-DIN-CP
Connection pins
FREQUENCY INPUT MODULES
MODEL INPUT RANGE
OUTPUT RANGE*
OM5-IFI-500-C 0 to 500Hz
0 to +5V
0 to +5V
0 to +5V
0 to +5V
0 to +5V
0 to +5V
0 to +5V
0 to +5V
*Note:
OM5-IFI-1K-C
OM5-IFI-3K-C
OM5-IFI-5K-C
0 to 1kHz
0 to 3kHz
0 to 5kHz
Any module not shown with a 10V output can be specified with 10V output.
Consult factory for minimum quantity and pricing details and module
specifications.
OM5-IFI-10K-C 0 to 10kHz
OM5-IFI-25K-C 0 to 25kHz
OM5-IFI-50K-C 0 to 50kHz
OM5-IFI-100K-C 0 to 100kHz
**THERMOCOUPLE ALLOY COMBINATIONS
TYPE
MATERIAL
J
Iron vs. Copper-Nickel
Nickel-Chromium vs. Nickel-Aluminum
Copper vs. Copper-Nickel
Nickel-Chromium vs. Copper-Nickel
Platinum-13% Rhodium vs. Platinum
Platinum-10% Rhodium vs. Platinum
Platinum-30% Rhodium vs.Platinum-6%Rhodium
Tungsten-5% Rhenium vs. Tungsten-26% Rhenium
Nickel-14.2% Chromium-1.4% Silicon vs. Nickel-4.4%
Silicon-0.1% Magnesium
LINEARIZED THERMOCOUPLE INPUT MODULES (0 to +5V OUTPUT*,
4Hz BW)
K
T
E
R
S
B
C
N
MODEL
TYPE**
INPUT RANGE
OM5-LTC-J1-C
OM5-LTC-J2-C
OM5-LTC-J3-C
OM5-LTC-J4-C
OM5-LTC-K1-C
OM5-LTC-K2-C
OM5-LTC-K3-C
OM5-LTC-K4-C
OM5-LTC-T1-C
OM5-LTC-T2-C
OM5-LTC-E-C
OM5-LTC-R-C
OM5-LTC-S-C
OM5-LTC-B-C
J
J
0°C to +760°C (+32°F to +1400°F)
–100°C to +300°C (–148°F to +572°F)
0°C to +500°C (+32°F to +932°F)
J
J
–100°C to +760°C (–148°F to +1400°F)
0°C to +1000°C (+32°F to +1832°F)
0°C to +500°C (+32°F to +932°F)
K
K
K
K
T
T
E
R
S
B
–100°C to +1350°C (–148°F to +2462°F)
0°C to +1200°C (+32°F to +2192°F)
–100°C to +400°C (–148°F to +752°F)
0°C to +200°C (+32°F to +392°F)
***RTD ALPHA COEFFICIENTS
TYPE
ALPHA COEFFICIENT
100Ω Pt
120Ω Ni
10Ω Cu
0.00385
0.00672
0.004274
0°C to +1000°C (+32°F to +1832°F)
+500°C to +1750°C (+932°F to +3182°F)
+500°C to +1750°C (+932°F to +3182°F)
+500°C to +1800°C (+932°F to +3272°F)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IMV/IV
Analog Voltage Input Modules, Narrow Bandwidth
FEATURES
● ACCEPTS MILLIVOLT AND VOLTAGE LEVEL SIGNALS
DESCRIPTION
Each OM5-IMV and OM5-IV voltage input module provides a single
channel of analog input which is filtered, isolated, amplified, and converted
to a high level analog voltage output (Figure 1). This voltage output is
logic-switch controlled, allowing these modules to share a common analog
bus without the requirement of external multiplexers.
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
The OM5 modules are designed with a completely isolated computer side
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
● 95dB NMR AT 60Hz, 90dB at 50Hz
●
●
●
0.05% ACCURACY
0.02% LINEARITY
1µV/°C DRIFT
Signal filtering is accomplished with a six-pole filter which provides 95dB
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter
are on the field side of the isolation barrier, and the other four are on the
computer side.
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
After the initial field-side filtering, the input signal is chopped by a
proprietary chopper circuit. Isolation is provided by transformer coupling,
again using a proprietary technique to suppress transmission of common
mode spikes or surges. The module is powered from +5VDC, 5%.
● MIX AND MATCH OM5 TYPES ON BACKPANELS
A special input circuit on the OM5-IMV and OM5-IV modules provides
protection against accidental connection of power-line voltages up to
240VAC.
4
NC
+EXC
+In
LPF
Isochopper™
20
4
3
2
1
Amplifier
LPF
VOUT
Surge
Suppression
and
6
Pat Pending
VIN
19
22
5
3
I/O Common
RD EN\
Protection
+V
–V
–In
–EXC
NC
Isolated
Computer-Side
Power
Backpanel
Term Block
1
NC
NC
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-IMV/IV Block Diagram.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Module
OM5-IMV
OM5-IV
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
10mV to 100mV
0.5nA
1V to 40V
0.05nA
50MΩ
40kΩ
40kΩ
650kΩ (minimum)
650kΩ (minimum)
650kΩ (minimum)
240Vrms max
ANSI/IEEE C37.90.1-1989
*
*
Transient
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
*
*
*
*
95dB at 60Hz, 90dB at 50Hz
Accuracy(1)
Nonlinearity
Stability
0.05% Span 10µV RTI(2) 0.05%(VZ(3)
)
0.05% Span 0.2mV RTI(2) 0.05%(VZ(3)
*
)
0.02% Span
Input Offset
Output Offset
Gain
1µV/°C
20µV/°C
25ppm/°C
20µV/°C
*
50ppm/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% Span
0.2µVrms
200µVrms
4Hz
2µVrms
*
*
*
0.2s
Output Range
5V, 0V to +5V
50Ω
*
*
*
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
Output Current Limit
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
)
*
*
8mA
Output Enable Control
Max Logic “0”
+0.8V
+2.4V
+36V
0.5µA
*
*
*
*
Min Logic “1”
Max Logic “1”
Input Current, “0”, “1”
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
*
*
2µV/% RTI(2)
200µV/% RTI(2)
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
*
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
*
*
*
*
*
0 to 95% Noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
MODEL
INPUT RANGE
OUTPUT RANGE
OM5-IMV-10A-C
OM5-IMV-50A-C
OM5-IMV-100A-C
OM5-IMV-10B-C
OM5-IMV-50B-C
OM5-IMV-100B-C
–10mV to +10mV
–50mV to +50mV
–100mV to +100mV
–10mV to +10mV
–50mV to +50mV
–100mV to +100mV
–5V to +5V
–5V to +5V
–5V to +5V
0V to +5V
0V to +5V
0V to +5V
* Same specification as OM5-IMV.
NOTES: (1) Includes nonlinearity,
hysteresis and repeatability.
(2) RTI = Referenced to input.
(3) VZ is the input voltage that results
in 0V output.
ORDERING
INFORMATION
OM5-IV-1A-C
OM5-IV-5A-C
OM5-IV-10A-C
OM5-IV-1B-C
OM5-IV-5B-C
OM5-IV-10B-C
OM5-IV-20A-C
OM5-IV-20B-C
OM5-IV-40A-C
OM5-IV-40B-C
–1V to +1V
–5V to +5V
–10V to +10V
–1V to +1V
–5V to +5V
–5V to +5V
–5V to +5V
0V to +5V
0V to +5V
0V to +5V
–5V to +5V
0V to +5V
–5V to +5V
0V to +5V
–5V to +5V
–10V to +10V
–20V to +20V
–20V to +20V
–40V to +40V
–40V to +40V
5
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-II
Analog Current Input Modules
FEATURES
DESCRIPTION
● ACCEPTS MILLIAMP LEVEL SIGNALS
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
Each OM5-II current input module provides a single channel of analog input
which is filtered, isolated, amplified, and converted to a high level analog
voltage output (Figure 1). This voltage output is logic switch controlled,
which allows these modules to share a common analog bus without the
requirement of external multiplexers.
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
The OM5-II modules are designed with a completely isolated computer side
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply connect-
ing pin 22, the Read-Enable pin to I/O Common, pin 19.
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
● 95dB NMR AT 60Hz, 90dB AT 50Hz
● 0.05% ACCURACY
A precision 20Ω current conversion resistor is supplied with the OM5-II
module. Sockets are provided on the OM5-BP backpanels to allow installa-
tion of this resistor. Extra resistors are available under part number OMX-
1362-C.
● 0.02% LINEARITY
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANELS
Signal filtering is accomplished with a six-pole filter which provides 95dB of
normal-mode rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are
onthefieldsideoftheisolationbarrier, andtheotherfourareonthecomputer
side.
Aftertheinitialfield-sidefiltering, theinputsignalischoppedbyaproprietary
chopper circuit. Isolation is provided by transformer coupling, again using
aproprietarytechniquetosuppresstransmissionofcommonmodespikesor
surges. The module is powered from +5VDC, 5%.
A special input circuit on the OM5-II modules provides protection against
accidental connection of power-line voltages up to 240VAC.
4
NC
+EXC
+In
LPF
Isochopper™
20
4
3
2
1
LPF
VOUT
Amplifier
Surge
Suppression
and
6
Pat Pending
IIN
19
22
5
3
I/O Common
RD EN\
Protection
+V
–V
–In
–EXC
NC
Isolated
Computer-Side
Power
20
Ω
0.1% plug-in
Backpanel
Term Block
1
NC
2
NC
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-II Block Diagram.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA = +25°C and +5V power.
OM5-II
Module
Input Range
Input Resistor
Value
0mA to 20mA or 4mA to 20mA
20.00Ω
0.1%
Accuracy
Stability
10ppm/°C
Input Protection
Continuous
Transient
240Vrms max
ANSI/IEEE C37.90.1-1989
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
95dB at 60Hz, 90dB at 50Hz
(2)
Accuracy(1)
Nonlinearity
0.05% span 0.05% (IZ
0.02% Span
)
Stability
Input Offset
Output Offset
Gain
Noise
50nA/°C
20µV/°C
25ppm/°C
Input, 0.1Hz to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% Span
10nArms
200µVrms
4Hz
0.2s
Output Range
0 to +5V
50Ω
Output Resistance
Output Protection
Output Selection Time
Continuous Short to Gnd
6µs at Cload = 0 to 2000pF
(to 1mV of V
)
Output Current LOimUTit
+8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
Max Logic “1”
Input Current, “0,1”
+0.8V
+2.4V
+36V
0.5µA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
20µV/% RTI(3)
Mechanical Dimensions
2.28" x 2.26" x 0.60"
(58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
-40°C to +85°C
-40°C to +85°C
0 to 95% Noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
NOTE: (1) Includes nonlinearity, hysteresis and repeatability. (2) IZ is the input current that
results in 0V output. (3) RTI = Referenced to input.
ORDERING INFORMATION
MODEL
INPUT RANGE
OUTPUT RANGE
BANDWIDTH
OM5-II-4/20-C
OM5-II-0/20-C
4mA to 20mA
0mA to 20mA
0V to +5V
0V to +5V
4Hz
4Hz
7
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IAC
Isolated True RMS Input Modules
FEATURES
DESCRIPTION
● INTERFACES RMS VOLTAGE (0 – 300V) OR RMS CURRENT (0 – 5A)
EachOM5-IACTrueRMSinputmoduleprovidesasinglechannelofACinput
which is converted to its True RMS dc value, filtered, isolated, amplified, and
converted to a standard process voltage or current output (Figure 1).
● DESIGNED FOR STANDARD OPERATION WITH FREQUENCIES OF
45HZ TO 1000HZ (EXTENDED RANGE TO 20Khz)
The OM5-IAC modules are designed with a completely isolated computer
side circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired,theoutputswitchcanbeturnedoncontinuouslybysimplyconnecting
pin 22, the Read-Enable pin to I/O Common, pin 19.
● COMPATIBLE WITH STANDARD CURRENT AND POTENTIAL
TRANSFORMERS
● INDUSTRY STANDARD 0-5V OUTPUT
● 0.25% FACTORY CALIBRATED ACCURACY (ACCURACY CLASS
0.2)
The field voltage or current input signal is processed through a pre-amplifier
and RMS converter on the field side of the isolation barrier. The converted dc
signalisthenchoppedbyaproprietarychoppercircuitandtransferredacross
the transformer isolation barrier, suppressing transmission of common
modespikesandsurges. Thecomputersidecircuitryreconstructs, filtersand
converts the signal to a 0-5VDC output. Modules are powered from +5VDC,
5%.
● 1500 VRMS CONTINUOUS TRANSFORMER BASED ISOLATION
● INPUT OVERLOAD PROTECTED TO 480V MAX (PEAK AC & DC) OR
10A RMS CONTINUOUS
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
4
Pre-Amp,
Conversion
+EXC
Isochopper™
20
4
LPF
VOUT or IOUT
Amplifier
Surge
Suppression
and
AC Source +In
6
Pat Pending
3
2
1
IIN
*
19
22
5
3
I/O Common
RD EN\
Protection
+V
–V
–In
–EXC
Isolated
Computer-Side
Power
Backpanel
Term Block
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
* Current Input Models Only
FIGURE 1. OM5-IAC Block Diagram.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA = +25°C and +5V power.
OM5-IAC
Module
Input
Signal Range
Standard Frequency Range
Extended Frequency Range
Impedance
100mV to 10V rms, 0 to 5A rms
45Hz to 1000Hz
1kHz to 20kHz
1 MΩ 1% shunted by 100pF (-01 thru -05),
0.05Ω 1% (-06, -07)
AC
Coupling
Protection(1)
Continuous
480V (Peak AC & DC)
Transient
ANSI/IEEE C37.90.1-1989
Output
Signal Range
0-5V
Current Limit
Voltage Limit
8mA
18V
Resistance
Protection
Ripple and Noise (100Khz)
50Ω
Continuous Short to Ground
0.025% Span rms
Accuracy(2)(3)
Sinusoid
50/60 Hz
0.25% Span
45Hz to 1kHz
1kHz to 20kHz
Non-Sinusoid
0.25% Reading Additional Factor
0.75% Reading Additional Factor
Crest Factor = 1 to 2
Crest Factor = 2 to 3
Crest Factor = 3 to 4
Crest Factor = 4 to 5
Vs. Temperature
0.05% Reading Additional Error
0.15% Reading Additional Error
0.30% Reading Additional Error
0.40% Reading Additional Error
100ppm/°C
ORDERING INFORMATION
MODEL
INPUT* (rms)
OUTPUT* (dc)
Isolation (Common Mode)
Input to Output, Input to Power
Continuous
Transient
Output to Power
Continuous
OM5-IAC-100B-C
OM5-IAC-1B-C
OM5-IAC-10B-C
0-100mV
0-1V
0-10V
0-5V
0-5V
0-5V
1500Vrms max
ANSI/IEEE C37.90.1-1989
50Vdc max
100dB
Rejection (50-60Hz Common Mode)
Response Time (0 to 99%)
<400ms
* Modules can be ordered with other input/output ranges. Consult factory for
ordering details and specifications.
Output Enable Control
Selection Time
Voltage
6.0µS @ CLOAD = 0 to 2000pF
Max Logic “0”
Min / Max Logic “1”
Current, “0,1”
+0.8V
+2.4V / +36V
0.5µA
Loop Voltage
Load Resistance (maximum)
+7.5Vdc min, +26Vdc max
(Loop Voltage - 14) / (Loop Current)
Supply Voltage
Current
Sensitivity
+5VDC 5%
30mA
200ppm/%
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
Immunity
Dimensions
-40˚ C to +85˚ C
-40˚ C to +85˚ C
0 to 90% noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
NOTE:
(1) Module rating only. Backpanel connector rating may differ — use the lowest of the two in
accordance with required safety requirements.
(2) At standard 60Hz factory calibration. Consult factory for calibration at other frequencies.
(3) For 10-100% rated span. Add an additional 0.25% error for 0-10% Span measurements.
Accuracy includes nonlinearity, hysteresis and repeatability but not source or external shunt
inaccuracy (if used).
9
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IP/IC/IN
Linearized 2- or 3-Wire RTD Input Modules
FEATURES
● INTERFACES TO 100Ω PLATINUM, 10Ω COPPER,
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
OR 120Ω NICKEL RTDs
● LINEARIZES RTD SIGNAL
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
RTD excitation is provided from the module by two matched current
sources. When using a three-wire RTD, this method allows an equal current
to flow in each RTD lead, which cancels the effects of lead resistances. The
excitation currents are very small (0.25mA for 100Ω Pt and 120Ω Ni, and
1.0mA for 10Ω Cu) which minimizes self-heating of the RTD.
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
Signal filtering is accomplished with a six-pole filter which provides 95dB
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter
are on the field side of the isolation barrier, and the other four are on the
computer side. After the initial field-side filtering, the input signal is
chopped by a proprietary chopper circuit. Isolation is provided by trans-
former coupling, again using a proprietary technique to suppress transmis-
sion of common mode spikes or surges. The module is powered from
+5VDC, 5%.
● 95dB NMR AT 60Hz, 90dB AT 50Hz
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
Each OM5 RTD input module provides a single channel of RTD input which
is filtered, isolated, amplified, linearized, and converted to a high level
analog voltage output (Figure 1). This voltage output is logic switch
controlled, which allows these modules to share a common analog bus
without the requirement of external multiplexers.
A special input circuit on the OM5 modules provides protection against
accidental connection of power-line voltages up to 240VAC.
The OM5 modules are designed with a completely isolated computer side
3 and 4 Wire(1)
2 Wire
20
VOUT
Linearizer
LPF
+EXC
4
6
LPF
Isochopper™
Amplifier
Pat Pending
4
3
2
1
19
22
I/O Common
RD EN\
Surge
Suppression
and
+In
RZ
RTD
5
3
Protection
+V
–V
–In
NC
Isolated
–EXC
Computer-Side
Power
4 Wire(1)
Backpanel
Term Block
1
–V
–V
NC
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
NOTE: (1) 4-wire sensors may be
used with this module. However,
for true 4-wire measurement,
use OM5-IP4/IC4/IN4.
Power Common
FIGURE 1. OM5-IP/IC/IN Block Diagram.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA= +25°C and +5V Power.
Module
OM5-IP/IC/IN
Input Range Limits
–200°C to +850°C (100Ω Pt)
–80°C to 320°C (120Ω Ni)
–100°C to 260°C (10Ω Cu)
Input Resistance
Normal
Power Off
50MΩ
40kΩ
40kΩ
Overload
Input Protection
Continuous
Transient
240Vrms max
ANSI/IEEE C37.90.1-1989
Sensor Excitation Current
100Ω Pt, 120Ω Ni
10Ω Cu
0.25mA
1.0mA
Lead Resistance Effect
100Ω Pt, 120Ω Ni
10Ω Cu
(1)
0.02°C/Ω
0.2°C/Ω
(1)
CMV, Input to Output
Continuous
Transient
CMR (50 or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
95dB at 60Hz, 90dB at 50Hz
Accuracy
Conformity Error
Stability
See Ordering Information
0.05% Span
Input Offset
Output Offset
Gain
0.02°C/°C
20µV/°C
50ppm of reading/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% Span
0.2µVrms
200µVrms
4Hz
0.2s
Output Range
0V to +5V
50Ω
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
ORDERING INFORMATION
MODEL
INPUT RANGE
OUTPUT RANGE ACCURACY†
(to 1mV of VOUT
)
100Ω Pt,
Output Current Limit
+8mA
α = 0.00385
OM5-IP-N100-C
–100°C to +100°C
(–148°F to +212°F)
0°C to +100°C
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0.32°C
0.13°C
0.26°C
0.78°C
Output Enable Control
Max Logic “0”
Min Logic “1”
Max Logic “1”
Input Current, “0,1”
+0.8V
+2.4V
+36V
0.5µA
OM5-IP-100-C
OM5-IP-200-C
OM5-IP-600-C
(+32°F to 212°F)
0°C to +200°C
(+32°F to 392°F)
0°C to +600°C
(+32°F to 1112°F)
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
100Ω Pt, 120Ω Ni
10Ω Cu
+5VDC 5%
30mA
10Ω Cu,
α = 0.004274
0.2°C/V
0.5°C/V
OM5-IC-120-01-C 0°C to +120°C (10Ω at 0°C)
(+32°F to +248°F)
0V to +5V
0V to +5V
0.23°C
Mechanical Dimensions
2.28" x 2.26" x 0.60" ( 58mm x 57mm x 15mm )
OM5-IC-120-02-C 0°C to +120°C (10Ω at 25°C)
(+32°F to +248°F)
0.23°C
Environmental
Operating Temperature Range
Storage Temperature Range
Relative Humidity
–40°C to +85°C
–40°C to +85°C
0 to 95% noncondensing
EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
EN50082-1, ISM Group 1,
Class A (ESD, RF, EFT)
Emissions
120Ω Ni,
α = 0.00672
OM5-IN-300-C
Immunity
0°C to +300°C
(+32°F to +572°F)
0V to +5V
0.40°C
†Includes conformity, hysteresis and repeatability.
NOTES: (1) "Ω" refers to the resistance in one lead.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IP4/IC4/IN4
Linearized 4-Wire RTD Input Modules
Each OM5 4-wire RTD input module provides a single channel of RTD input
FEATURES
which is filtered, isolated, amplified, linearized, and converted to a high
level analog voltage output. This voltage output is logic switch controlled,
which allows these modules to share a common analog bus without the
requirement of external multiplexers.
●
INTERFACES TO 100Ω PLATINUM, 10Ω COPPER,
OR 120Ω NICKEL RTDs
● TRUE 4-WIRE INPUT
The OM5 modules are designed with a completely isolated computer side
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
● LINEARIZES RTD SIGNAL
● HIGH LEVEL VOLTAGE OUTPUT
● 1500Vrms TRANSFORMER ISOLATION
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
RTD excitation is provided from the module by a precision current source.
The excitation current is available on two leads which are separate from the
two input signal measuring leads. The excitation current does not flow in
the input signal leads, which allows RTD measurement to be totally
independent of lead resistance. The excitation current is very small (0.25mA
for 100 Ω Pt and 120 Ω Ni and 1.0 mA for 10Ω Cu) which minimizes self-
heating of the RTD.
● 95dB NMR AT 60HZ, 90dB AT 50HZ
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
Signal filtering is accomplished with a six-pole filter which provides 95dB
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter
are on the field side of the isolation barrier, and the other four are on the
computer side. After the initial field-side filtering, the input signal is
chopped by a proprietary chopper circuit. Isolation is provided by trans-
former coupling, again using a proprietary technique to suppress transmis-
sion of common mode spikes or surges. The module is powered from
+5VDC, 5%.
DESCRIPTION
In RTD temperature measurement applications requiring a very high level
of accuracy, the OM5 4-Wire RTD input module offers a significant
advantage over 3-wire measurement techniques (Figure 1). The OM5
measures only the voltage dropped across the RTD and almost completely
ignores the resistance or length of the RTD lead wires. The OM5
3-Wire RTD module provides lead resistance compensation, but requires
equal lead resistances, while the 4-wire modules do not require matched
lead resistances.
A special input circuit provides protection against accidental connection of
power-line voltages up to 240VAC.
20
VOUT
Linearizer
LPF
+EXC
+In
4
6
LPF
Isochopper™
Amplifier
Pat Pending
4
3
2
1
19
22
I/O Common
RD EN\
Surge
Suppression
and
RTD
5
3
Protection
+V
–V
–In
4 Wire
RTD
Isolated
Computer-Side
Power
–EXC
Backpanel
Term Block
1
–V
NC
2
NC
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-IP4/IC4/IN4 Block Diagram.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA = +25°C and +5V Power.
Module
OM5-IP4/IC4/IN4
Input Range Limits
–200°C to +850°C (100Ω Pt)
–80°C to +320°C (120Ω Ni)
–100°C to +260°C (10Ω Cu)
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
50MΩ
40kΩ
40kΩ
240Vrms max
ANSI/IEEE C37.90.1-1989
Sensor Excitation Current
100Ω Pt, 120Ω Ni
10Ω Cu
0.25mA
1.0mA
Lead Resistance Effect
100Ω Pt, 120Ω Ni
10Ω Cu
(1)
0.0005 °C/Ω
(1)
0.005 °C/Ω
CMV, Input to Output
Continuous
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
Transient
CMR (50Hz or 60Hz)
NMR
95dB at 60Hz, 90dB at 50Hz
Accuracy
Conformity Error
Stability
See Ordering Information
0.05% Span
Input Offset
Output Offset
Gain
0.02°C/°C
20µV/°C
50ppm of reading/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% span
0.2µVrms
200µVrms
4Hz
0.2s
Output Range
0V to +5V
50Ω
Continuous short to ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
+0.8V
+2.4V
+36V
0.5µA
Min Logic “1”
Max Logic “1”
Input Current, “0,1”
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
100Ω Pt, 120Ω Ni
10Ω Cu
+5VDC 5%
30mA
0.2°C/V
0.5°C/V
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
0 to 95% noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
NOTES: (1) “Ω” refers to the resistance
in one lead.
Immunity
ORDERING
INFORMATION
MODEL
INPUT RANGE
OUTPUT RANGE
0V to +5V
ACCURACY†
100 Ω Pt, α = 0.00385
OM5-IP4-N100-C
OM5-IP4-100-C
OM5-IP4-200-C
OM5-IP4-600-C
–100°C to +100°C (–148°F to +212°F)
0°C to +100°C (+32°F to 212°F)
0°C to +200°C (+32°F to 392°F)
0°C to +600°C (+32°F to 1112°F)
0.32°C
0.13°C
0.26°C
0.78°C
0V to +5V
0V to +5V
0V to +5V
10 Ω Cu, α = 0.004274
OM5-IC4-120-01-C
OM5-IC4-120-02-C
†Includes conformity,
hysteresis and repeatability.
0°C to +120°C (10Ω at 0°C) (+32°F to +248°F)
0°C to +120°C (10Ω at 25°C) (+32°F to +248°F)
0V to +5V
0V to +5V
0.23°C
0.23°C
120 Ω Ni, α = 0.00672
OM5-IN4-300-C
0°C to +300°C (+32°F to +572°F)
0V to +5V
0.40°C
13
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-PT
Potentiometer Input Modules
FEATURES
DESCRIPTION
● INTERFACES TO POTENTIOMETERS UP TO 10,000 OHMS
Each OM5-PT Potentiometer input module provides a single channel of
potentiometer input which is filtered, isolated, amplified, and converted to a
high level analog voltage output (Figure 1). This voltage output is logic
switch controlled, which allows these modules to share a common analog
bus without the requirement of external multiplexers.
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500 VOLT TRANSFORMER ISOLATION
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
The OM5 modules are designed with a completely isolated computer side
circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
● 95dB NMR AT 60HZ, 90dB AT 50HZ
● MIX AND MATCH OM5 TYPES ON BACKPANEL
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
Excitation for the potentiometer is provided from the module by two matched
current sources. When using a three-wire potentiometer, this method allows
cancellationoftheeffectsofleadresistances. Theexcitationcurrentsarevery
small (less than 1.0mA) which minimizes self-heating of the potentiometer.
Signal filtering is accomplished with a six-pole filter which provides 95dB of
normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are
on the field side of the isolation barrier, and the other four are in the output
stage. After the initial field-side filtering, the input signal is chopped by a
proprietary chopper circuit. Isolation is provided by transformer coupling,
again using a proprietary technique to suppress transmission of common
mode spikes or surges. The module is powered from +5VDC, 5%.
A special input circuit provides protection against accidental connection of
power-line voltages up to 240VAC.
3-Wire
Potentiometer
+EXC
+In
4
6
LPF
Isochopper™
20
4
3
2
4
3
2
1
Amplifier
LPF
VOUT
Surge
Suppression
and
Pat Pending
19
22
5
3
Protection
I/O Common
RD EN\
+V
–V
–In
2-Wire
Slidewire
NC
Isolated
–EXC
Computer-Side
Power
Backpanel
Term Block
1
–V
–V
NC
2
17
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
16
Power Common
FIGURE 1. OM5-PT Block Diagram.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at Ta = +25˚C and +5V Power
Module
OM5-PT
Input Range
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
0 to 10KΩ
50MΩ
40KΩ
40KΩ
240Vrms max
ANSI/IEEE C37.90.1-1989
Sensor Excitation Current
0.25mA; 100Ω, 500Ω, 1KΩ sensor
0.10mA; 10KΩ sensor
0.01Ω/Ω; 100Ω, 500Ω, 1KΩ sensor
0.02Ω/Ω; 10KΩ sensor
Lead Resistance Effect
CMV, Input to Output
Continuous
Transient
CMR (50 or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
95dB @ 60Hz, 90dB @ 50Hz
Accuracy(2)
Stability
0.08% Span
Input Offset
0.004Ω/°C; 100Ω, 500Ω, 1KΩ sensor
0.010Ω/°C; 10KΩ sensor
Output Offset
Gain
20µV/°C
50ppm of reading/°C
Noise
Input, 0.1 to 10Hz
Output, 100KHz
Bandwidth, -3dB
Response Time, 90% span
0.2µVrms
200µVrms
4Hz
0.2s
Output Range
0 to +5V
50Ω
Continuous short to ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
+0.8V
+2.4V
+36V
0.5µA
Min Logic “1”
Max Logic “1”
Input Current, “0,1”
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
2µV/% RTI(1)
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
-40°C to +85°C
-40°C to +85°C
0 to 95% noncondensing
EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
EN50082-1, ISM Group 1,
Class A (ESD, RF, EFT)
Immunity
NOTES: (1) Referenced to input. (2) Includes nonlinearity, hysteresis and repeatability.
ORDERING INFORMATION
MODEL
INPUT RANGE
OUTPUT RANGE
OM5-PT-100-C
OM5-PT-500-C
OM5-PT-1K-C
OM5-PT-10K-C
0 to 100Ω
0 to 500Ω
0 to 1KΩ
0 to 10KΩ
0V to +5V
0V to +5V
0V to +5V
0V to +5V
15
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-ITC
Thermocouple Input Modules
The OM5-ITC modules are designed with a completely isolated computer
FEATURES
● INTERFACES TO TYPES J, K, T, E, R, S, C, N AND B
side circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
THERMOCOUPLES
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
The OM5-ITC can interface to nine industry standard thermocouple types:
J, K, T, E, R, S, C, N, and B. Its corresponding output signal operates over
a 0V to +5V range. Each module is cold-junction compensated to correct
for parasitic thermocouples formed by the thermocouple wire and screw
terminals on the mounting backpanel. Upscale open thermocouple detect
is provided by an internal pull-up resistor. Downscale indication can be
implemented by installing an external 47MΩ resistor, 20% tolerance,
between screw terminals 1 and 3 on the OM5-BP backpanels.
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● 160dB CMR
● 95dB NMR AT 60Hz, 90dB at 50Hz
● 0.05% ACCURACY
Signal filtering is accomplished with a six-pole filter which provides 95dB
of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter
are on the field side of the isolation barrier, and the other four are on the
computer side.
● 0.02% LINEARITY
●
1µV/°C DRIFT
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
After the initial field-side filtering, the input signal is chopped by a
proprietary chopper circuit. Isolation is provided by transformer coupling,
again using a proprietary technique to suppress transmission of common
mode spikes or surges. The module is powered from +5VDC, 5%.
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
A special input circuit provides protection against accidental connection of
power-line voltages up to 240VAC.
Each OM5-ITC Thermocouple input module provides a single channel of
thermocouple input which is filtered, isolated, amplified, and converted to
a high level analog voltage output (Figure 1). This voltage output is logic-
switch controlled, allowing these modules to share a common analog bus
without the requirement of external multiplexers.
+2.5V
100MΩ
4
NC
+EXC
+In
LPF
Isochopper™
20
4
3
2
1
LPF
Amplifier
VOUT
Surge
Suppression
and
6
Pat Pending
Thermocouple
19
22
5
3
Protection
I/O Common
RD EN\
+V
–V
–In
–EXC
Isolated
Precision
Computer-Side
Power
Reference
Backpanel
Term Block
CJC
1
2
17
16
+V
–V
+5V
Temp
Sensor
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-ITC Block Diagram.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS Typical at TA = +25°C and +5V power.
Module
OM5-ITC
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous
Transient
-0.1V to +0.5V
-25nA
50MΩ
40kΩ
40kΩ
240Vrms max
ANSI/IEEE C37.90.1-1989
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1-1989
160dB
95dB at 60Hz, 90dB at 50Hz
Accuracy
Nonlinearity
Stability
Input Offset
Output Offset
Gain
See Ordering Information
0.02% Span
1µV/°C(3)
20µV/°C
25ppm/°C
Noise
Input, 0.1 to 10Hz
Output, 100kHz
Bandwidth, –3dB
Response Time, 90% Span
0.2µVrms
200µVrms
4Hz
0.2s
Output Range
0V to +5V
50Ω
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
)
Output Current Limit
+8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
+0.8V
+2.4V
+36V
Max Logic “1”
Input Current, “0”, “1”
Open Input Response
Open Input Detection Time
Cold Junction Compensation
Accuracy, 25°C
Accuracy, +5°C to +45°C
Accuracy, –40°C to +85°C
0.5µA
Upscale
10s
0.25°C
0.5°C
1.25°C
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
30mA
2µV/% RTI(2)
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
Environmental
NOTES: (1) Includes nonlinearity, hysteresis
and repeatability. Does not include CJC
accuracy. (2) RTI = Referenced to input.
(3)This is equivalent to °C as follows: Type J
0.020 °C/°C, Types K, T 0.025°C/°C,
Type E 0.016°C/°C, Types R, S 0.168°C/°C.
Type N 0.037°C/°C, Type C, 0.072°C/°C.
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
0 to 95% Noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
ORDERING
INFORMATION
MODEL
TYPE
INPUT RANGE
OUTPUT RANGE
ACCURACY(1)
OM5-ITC-J-C
OM5-ITC-K-C
OM5-ITC-T-C
OM5-ITC-E-C
OM5-ITC-R-C
OM5-ITC-S-C
OM5-ITC-B-C
OM5-ITC-C1-C
OM5-ITC-N1-C
Type J
Type K
Type T
Type E
Type R
Type S
Type B
Type C
Type N
–100°C to +760°C (–148°F to +1400°F)
–100°C to +1350°C (–148°F to +2462°F)
–100°C to +400°C (–148°F to +752°F)
0°C to +900°C (+32°F to +1652°F)
0°C to +1750°C (+32°F to +3182°F)
0°C to +1750°C (+32°F to +3182°F)
0°C to +1800°C (+32°F to +3272°F)
+350°C to +1300°C (+662°F to +2372°F)
–100°C to +1300°C (–148°F to +2372°F)
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
0V to +5V
OV to +5V
0V to +5V
0.07%
0.07%
0.09%
0.07%
0.10%
0.10%
0.12%
0.11%
0.70%
0.61˚C
0.97˚C
0.46˚C
0.59˚C
1.72˚C
1.82˚C
2.21˚C
1.01˚C
0.98˚C
17
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-WBS
Strain Gage Input Modules, Wide Bandwidth
FEATURES
The OM5-WBS modules are designed with a completely isolated computer
side circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
● INTERFACES TO 100Ω THRU 10kΩ, FULL-BRIDGE, HALF-BRIDGE,
OR QUARTER-BRIDGE STRAIN GAGES
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
The OM5-WBS can interface to full-bridge or half-bridge transducers with
a nominal resistance of 100Ω to 10kΩ. A matched pair of bridge-
completion resistors (to 1mV at +10V excitation) allows use of low cost
half-bridge or quarter-bridge transducers (Figures 2, 3, 4). The 10kHz
bandwidth allows measurement of high speed processes such as vibration
analysis.
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● FULLY ISOLATED EXCITATION SUPPLY
● 100dB CMR
Strain Gage excitation is provided from the module by a very stable 10V
or 3.333V source. The excitation supply is fully isolated, allowing the
amplifier inputs to operate over the full range of the excitation voltage. This
feature offers significant flexibility in real world applications. Full scale
sensitivities of 2mV/V, 3mV/V or 10mV/V are offered as standard. With 10V
excitation, this results in 20mV, 30mV or 100mV full scale input range
producing 5V full scale output.
● 10kHz SIGNAL BANDWIDTH
●
●
●
0.08% ACCURACY
0.02% LINEARITY
1µV/°C DRIFT
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
The input signal is processed through a pre-amplifier on the field side of
the isolation barrier. This pre-amplifier has a gain-bandwidth product of
5MHz and is bandwidth limited to 10kHz. After amplification, the input
signal is chopped by a proprietary chopper circuit. Isolation is provided by
transformer coupling, again using a proprietary technique to suppress
transmission of common mode spikes or surges. The module is powered
from +5VDC, 5%.
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
Each OM5-WBS Strain Gage input module provides a single channel of
strain gage input which is filtered, isolated, amplified, and converted to a
high level analog voltage output (Figure 1). This voltage output is logic
switch controlled, which allows these modules to share a common analog
bus without the requirement of external multiplexers.
Special input circuits provide protection of the signal inputs and the
isolated excitation supply up to 240VAC.
+EXC
+In
4
LPF
Isochopper™
20
Strain
Gage
4
3
2
1
LPF
Amplifier
VOUT
Surge
Suppression
and
6
5
3
Pat Pending
19
22
Protection
I/O Common
RD EN\
+V
–V
–In
Isolated
Excitation
Source
Isolated
Computer-Side
Power
–EXC
Backpanel
Term Block
1
2
17
16
+V
–V
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power
Common
FIGURE 1. OM5-WBS Block Diagram.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 2. Full Bridge Connection.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Full Bridge
OM5-WBS38-01-C, -WBS-1/-2/-4/-5-C
Half Bridge
OM5-WBS38-03-C,-WBS-3-C
Module
4
+EXC
+In
4
6
5
3
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Signal Input Protection
Continuous
Transient
10mV to 100mV
0.3nA
*
*
V
EXC
3
2
1
(1)
R
(1)
g
R
g
50MΩ
40kΩ
40kΩ
*
*
*
–In
(1)
R
(1)
g
R
g
240Vrms max
ANSI/IEEE C37.90.1-1989
*
*
–EXC
OM5-WBS38-01-C
OM5-WBS-1-C
OM5-WBS-2-C
OM5-WBS-4-C
OM5-WBS-5-C
Backpanel
Terminal Block
Excitation Output (-1/-2/-3/-5-C)
Excitation Output (-4-C,-01/-03-C)
Excitation Load Regulation
Excitation Stability
Half Bridge Voltage Level (-3-C)
Half Bridge Voltage Level (-03-C)
Isolated Excitation Protection
Continuous
+10V 3mV
+3.333V 2mV
5ppm/mA
15ppm/°C
NA
*
*
*
*
+5V 1mV
+1.667V 1mV
NA
FIGURE 3. Half Bridge Connection.
240Vrms max
ANSI/IEEE C37.90.1-1989
*
*
Transient
CMV, Input to Output
Continuous
Transient
CMR (50 or 60Hz)
NMR (–3dB at 10kHz)
Accuracy(2)
Nonlinearity
Stability
Input Offset
Output Offset
Gain
4
+EXC
+In
4
6
5
3
1500Vrms max
ANSI/IEEE C37.90.1-1989
100dB
*
*
*
*
(1)
R
V
R
g
EXC
1
3
2
1
120dB per Decade above 10kHz
0.08% Span 10µV RTI(3)
*
*
–In
0.02% Span
NC
(1)
R
R
2
g
1µV/°C
40µV/°C
25ppm of Reading/°C
*
*
*
OM5-WBS38-03-C
OM5-WBS-3-C
–EXC
R
= R
2
1
Backpanel
Terminal Block
Noise
Input, 0.1 to 10Hz
Output, 100kHz
0.4µVrms
10mVp-p
2µVrms
*
Bandwidth, –3dB
Rise Time, 10 to 90% span
Setting Time, to 0.1%
10kHz
35µs
250µs
*
*
*
FIGURE 4. Quarter Bridge Connection.
Output Range
5V
50Ω
*
*
*
*
Output Resistance
Output Protection
Output Selection Time
(to 1mV of VOUT
Output Current Limit
4
Continuous Short to Ground
6µs at Cload = 0 to 2000pF
+EXC
+In
4
6
5
3
(1)
V
R
R
EXC
g
1
)
3
2
1
8mA
Output Enable Control
Max Logic “0”
Min Logic “1”
Max Logic “1”
Input Current, “0,1”
–In
+0.8V
+2.4V
+36V
0.5µA
*
*
*
*
NC
R
R
3
2
OM5-WBS38-03-C
OM5-WBS-3-C
–EXC
R
= R
2
1
Customer
Supplied
Backpanel
Terminal Block
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
170mA Full Exc. Load, 70mA No Exc. Load
2µV/% RTI(3)
*
*
*
Mechanical Dimensions
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
*
Environmental
* Same as Full Bridge modules.
NOTES: (1) Strain element. (2) Includes excitation error, nonlinearity,
hysteresis and repeatability. (3) Referenced to input.
Operating Temperature Range
Storage Temperature Range
Relative Humidity
–40°C to +85°C
–40°C to +85°C
*
*
*
*
0 to 95% Noncondensing
Emissions
EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
*
ORDERING
INFORMATION
MODEL (10kHz) INPUT BRIDGE TYPE
INPUT RANGE
EXCITATION
OUTPUT RANGE
OM5-WBS38-01-C
OM5-WBS-1-C
OM5-WBS38-03-C
OM5-WBS-3-C
OM5-WBS-2-C
OM5-WBS-4-C
OM5-WBS-5-C
Full Bridge
Full Bridge
Half Bridge
Half Bridge
Full Bridge
Full Bridge
Full Bridge
100Ω to 10kΩ
300Ω to 10kΩ
100Ω to 10kΩ
300Ω to 10kΩ
300Ω to 10kΩ
100Ω to 10kΩ
300Ω to 10kΩ
3.333V at 3mV/V Sensitivity
10.0V at 3mV/V Sensitivity
3.333V at 3mV/V Sensitivity
10.0V at 3mV/V Sensitivity
10.0V at 2mV/V Sensitivity
3.333V at 10mV/V Sensitivity
10.0V at 10mV/V Sensitivity
-5V to +5V
–5V to +5V
-5V to +5V
–5V to +5V
–5V to +5V
–5V to +5V
–5V to +5V
19
Download from Www.Somanuals.com. All Manuals Search And Download.
OM5-IVI
Current Output Modules
DESCRIPTION
FEATURES
Each OM5-IVI current output module provides a single channel of analog
output. The track-and-hold circuit in the input stage can be operated in a
hold mode where one DAC can supply many output modules, or a track
mode where one DAC is dedicated to each module. In addition to the track-
and-hold circuit, each module provides signal buffering, isolation, filtering,
and conversion to a high level current output (Figure 1).
● ACCEPTS HIGH LEVEL VOLTAGE OR PROCESS CURRENT INPUT
● UNIPOLAR OR BIPOLAR CURRENT OUTPUT
● 1500Vrms TRANSFORMER ISOLATION
●
ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● OUTPUT PROTECTED TO 240VAC CONTINUOUS
● 110dB CMR
Setting of the track or hold mode is controlled by the logic state of WR EN\,
module pin 23. When pin 23 is low, the track mode is enabled. If pin 23
is open or high, the hold mode is enabled. The module is designed with a
completely isolated computer side circuit which can be floated to 50V
from Power Common, pin 16. This complete isolation means that no
connection is required between I/O Common and Power Common for
proper operation of the track and hold circuit. For a low state, simply
connect pin 23, the Write-Enable pin, to I/O Common, pin 19.
● 400Hz SIGNAL BANDWIDTH
● 0.05% ACCURACY
● 0.02% LINEARITY
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
The OM5-BP-16-MUX backpanels allow host computer control of the WR
EN\ control line, which allows multiplexing of one host DAC to up to 64
OM5-IVI output modules. During power-up, the output remains at 0mA for
100ms on all models, which allows the track-and-hold circuit to be
initialized.
A special circuit in the output stage of the module provides protection
against accidental connection of power-line voltages up to 240VAC.
Isolation Barrier
Track
&
Hold
18
19
23
Range
Select
VIN / +IIN
+EXC
4
NC
4
+Out
6
5
3
I/O Common / –IIN
WR EN\
Surge
Suppression
and
RLOAD
3
2
1
Protection
–Out
+V
–V
NC
–EXC
Isolated
Computer-Side
Power
Backpanel
Term Block
1
NC
NC
2
17
16
+5V
Isolated
Field-Side
Power
Power
Oscillator
Power Common
FIGURE 1. OM5-IVI Block Diagram.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONSTypical at TA = +25°C and +5V power.
Unipolar Output Current
OM5-IVI
Module
Input Voltage Range
5V or 0V to +5V
0 to 20mA
Input Current Range (–05)
Input Voltage Maximum
Input Current, Maximum (–05)
Input Resistance
36V (no damage)
75mA (no damage)
50MΩ
Input Resistance (–05)
20Ω
Output Current Range
Over Range Capability
Output Compliance Voltage
(Open Circuit)
0 to 20mA or 4 to 20mA
10%
22VDC
0 to 650Ω
Load Resistance Range
(0 to 750Ω for Power Supply Voltage
greater than 4.95VDC)
26mA
Output I Under Fault, max
Output Protection
Continuous
240Vrms max
Transient
ANSI/IEEE C37.90.1-1989
CMV, Output to Input
Continuous
Transient
CMR (50Hz or 60Hz)
NMR (–3dB at 400 Hz)
1500Vrms max
ANSI/IEEE C37.90.1-1989
110dB
40dB per Decade above 400Hz
Accuracy
Nonlinearity
0.05% Span
0.02% Span
Stability
Zero
Span
Noise
0.5µA/°C
20ppm/°C
Output Ripple, 1kHz bandwidth
Bandwidth, –3dB
Rise Time, 10 to 90% Span
10µAp-p
400Hz
0.75ms
Sample and Hold
Output Droop Rate
Acquisition Time
40µA/s
50µs
Track-and-Hold Enable Control
Max Logic “0”
Min Logic “1”
Max Logic “1”
Input Current, “0”
+0.8V
+2.4V
+36V
0.5µA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
+5VDC 5%
170mA
0.5µA/% typ
Mechanical Dimensions
2.28" x 2.26" x 0.6" (58mm x 57mm x 15mm)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions
–40°C to +85°C
–40°C to +85°C
0 to 95% Noncondensing
EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Immunity
* same specification
ORDERING INFORMATION
MODEL
INPUT RANGE OUTPUT RANGE BANDWIDTH
OM5-IVI-B4-C
OM5-IVI-A4-C
OM5-IVI-B0-C
OM5-IVI-A0-C
0V to +5V
–5V to +5V
0V to +5V
–5V to +5V
4mA to 20mA
4mA to 20mA
0mA to 20mA
0mA to 20mA
400Hz
400Hz
400Hz
400Hz
21
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace
period to the normal one (1) year product warranty to cover handling and shipping time.
This
ensures that OMEGA's customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer
Service Department will issue an Authorized Return (AR) number immediately upon phone or written
request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at
no charge. OMEGA's WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or
current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA's control. Components which wear are not warranted, including but not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be
as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based.
consequential, incidental or special damages.
In no event shall OMEGA be liable for
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic
Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
FOR NON-WARRANTY REPAIRS, consult OMEGA
for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1. P.O. number under which the product was
PURCHASED,
1. P.O. number to cover the COST
of the repair,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior
written consent of OMEGA ENGINEERING, INC.
Download from Www.Somanuals.com. All Manuals Search And Download.
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
þ
þ
þ
þ
þ
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gauges
Load Cells & Pressure Gauges
Displacement Transducers
þ
þ
þ
þ
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
þ
þ
þ
þ
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
þ
þ
þ
þ
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
þ
þ
þ
þ
þ
Recorders, Printers & Plotters
HEATERS
Heating Cable
þ
þ
þ
þ
þ
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
þ
þ
þ
þ
þ
þ
M1516