Input Protection:
24V dc or 24V ac rms maximum input voltage on any
combination of input pins.
Reading Rate: 2.5 time per second.
INTRODUCTION
The instrument is a portable digital thermometer that
measures external thermocouples of type K, J, R, S, T, E,
N. The thermocouples types comply with the N.I.S.T. –
ITS 90 standard reference temperature/voltage tables.
The thermometer features a dual thermocouple input, an
adjustable T/C offset and an USB interface for uploading
data to a PC using optional software and cable.
OMEGAnet® On-Line Service
omega.com
Internet e-mail
HH806U/HH806AU
MULTILOGGER THERMOMETER
ENVIRONMENTAL
Ambient Operating Ranges:
0°C to 50°C (32°F to 122°F) <80% R.H.
Storage Temperature:
Servicing North America:
M4502/0707
U.S.A:
One Omega Drive, Box 4047
Stamford, CT 06907-0047
INSTRUCTION
SHEET
Shop online at: omega.com e-mail: [email protected]
For latest product manuals: omegamanual.info
ISO 9001 Tel: (203) 359-1660
Certified
FAX: (203) 359-7700
-20°C to 60°C (-4°F to 140°F) <70% R.H.
e-mail: [email protected]
SAFETY INFORMATION
Canada:
976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928
e-mail: [email protected]
GENERAL
WARNING
FAX: (514) 856-6886
Display:
To avoid electrical shock, do not use this instrument
when working voltages at the measurement surface
over 24V AC or DC.
There are three display areas on the HH806 series LCD
(liquid crystal display). The Main and Second displays
are 4 ½ digits with a maximum reading of 19999. These
are used for displaying the value of T1 or T2. The Third
display is for the date, time, or the differential value of
T1 to T2.
For immediate technical or application assistance:
U.S.A
and
Canada:
Sales Service: 1-800-826-6342/1-800-TC-OMEGA®
Customer Service: 1-800-622-2378/1-800-622-BEST®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
WARNING
To avoid damage or burns, do not make temperature
measurement in microwave ovens.
Overload: “----.-” or “OL” is display.
Mexico:
En Espanol: (001) 203-359-7803
e-mail: [email protected]
Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03.
Battery Life: 120 hours typical with carbon zinc battery.
Dimensions: 160mm(H) x 83mm(W) x 38mm(D).
Weight: Approx. 365g including batteries.
Supplied Thermocouple:
1 meter (40”) type K insulated beaded wire thermocouple.
Maximum insulation temperature is 482°C (900°F).
Thermocouple accuracy is ±1.1°C or 0.4% of reading
(whichever is greater) from 0°C to 1250°C.
Wire Communication Protocol:
CAUTION
Repeated sharp flexing can break the thermocouple
leads. To prolong lead life, avoid sharp bends in the
leads, especially near the connector.
Servicing Europe:
Benelux: Postbus 8034, 1180 LAAmstelveen, The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: [email protected]
SPECIFICATIONS
Czech
Frystatska 184, 733 01 Karviná, Czech Republic
Republic: Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114
ELECTRICAL
Temperature Scale: Celsius or Fahrenheit user-selectable
Measurement Range:
2400 baud rate. (HH806U)
19200 baud rate. (HH806A)
France:
11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427
Toll Free in France: 0800 466 342
K-TYPE (0.1°) -200°C to 1372°C (-328°F to 2501°F)
J-TYPE (0.1°) -210°C to 1200°C (-346°F to 2192°F)
T-TYPE (0.1°) -200°C to 400°C (-328°F to 752°F)
E-TYPE (0.1°) -210°C to 1000°C (-346°F to 1832°F)
e-mail: [email protected]
1
2
External Connections:
1. USB Port
2. DC power JACK(12V)
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Austria:
Tel: + 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: [email protected]
R-TYPE (1°)
S-TYPE (1°)
0°C to 1767°C (32°F to 3212°F)
0°C to 1767°C ( 32°F to 3212°F)
United
One Omega Drive, River Bend Technology Centre
N-TYPE (0.1°) -50°C to 1300°C ( -58°F to 2372°F)
*Based on the ITS-90 temperature standard.
According to temperature standard ITS-90.
Accuracy:
Kingdom: Northbank, Irlam, Manchester
ISO 9002 M44 5BD United Kingdom
Certified
Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]
K/J/T/E-TYPE
±(0.05% rdg + 0.3°C) on -50°C to 1372°C
±(0.05% rdg + 0.7°C) on -50°C to -210°C
±(0.05% rdg + 0.6°F) on -58°F to 2501°F
±(0.05% rdg + 1.4°F) on -58°F to -346°F
N-TYPE
±(0.05% rdg + 0.8°C) on -50°C to 0°C
±(0.05% rdg + 0.4°C) on 0°C to 1300°C
±(0.05% rdg + 1.6°F) on -58°F to 32°F
±(0.05% rdg + 0.8°F) on 32°F to 2372°F
R/S-TYPE
It is the policy of OMEGA Engineering, Inc. to comply with all
worldwide safety and EMC/EMI regulations that apply. OMEGA
is constantly pursuing certification of its products to the
European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be
correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without
notice.
±(0.05% rdg + 2°C) on 0°C to 1767°C
±(0.05% rdg + 4°F) on 32°F to 3212°F
Temperature Coefficient:
WARNING: These products are not designed for use in, and
should not be used for, human applications.
0.1 times the applicable accuracy specification per °C
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and
82°F to122°F).
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY / DISCLAIMER
the top-right of the LCD and the previous interval is
displayed. Press the number buttons printed in white
on the overlay to change the time interval. Setting is
from left to right of the following format (HH:MM:SS).
Press the overlay “ENTER” button to confirm. To exit
this function, press the ESC button.
Where Do I Find Everything I Need
for Process Measurement
and Control?
OPERATOR MAINTENANCE
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in
materials and workmanship for a period of 13 months from date of purchase.
OMEGA’s WARRANTY adds an additional one (1) month grace period to the
normal one (1) year product warranty to cover handling and shipping time.
This ensures that OMEGA’s customers receive maximum coverage on each
product.
WARNING
To avoid possible electrical shock, disconnect the
thermocouple connectors from the thermometer before
removing the cover.
OMEGA…Of Course!
Shop online at omega.com
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return
(AR) number immediately upon phone or written request. Upon examination
by OMEGA, if the unit is found to be defective, it will be repaired or replaced
at no charge. OMEGA’s WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling,
improper interfacing, operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the unit shows
evidence of having been tampered with or shows evidence of having been
damaged as a result of excessive corrosion; or current, heat, moisture or
vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear is not
warranted, include but are not limited to contact points, fuses, and triacs.
HH: interval Hour (0~23)
MM: interval Minute (0~59)
SS: interval Second (0~59)
MAX: 23:59:59
Battery Replacement
1. Power is supplied by 4pcs 1.5V (AAA SIZE) UM-4
R03.
2. The “ ” appears on the LCD display when replace-
ment is needed. To replace battery remove screw from
back of meter and lift off the battery cover.
3. Remove the battery from battery contacts and replace.
4. When not in use for long periods remove battery.
5. Do not store in locations with high temperatures, or
high humidity.
TEMPERATURE
Thermocouple, RTD & Thermistor Probes,
Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
MIN: 00:00:01
(8) “APO” Button (Auto power off time setting,
min. 1 minute)
Use this function to change the time for the auto power
off (APO) function. Press the APO button in setup
mode, and the indicator “APO” and the current time
will flash on the LCD. The default time for APO is 5
minutes. Press the number button printed in white on
the overlay to set the APO time. Press the overlay
“ENTER” button to confirm. To exit this function
without changing the setting, press the ESC button.
MAX: 19999 minutes
OMEGA is pleased to offer suggestions on the use of its various
products. However, OMEGA neither assumes responsibility for any
omissions or errors nor assumes liability for any damages that result
from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the
parts manufactured by it will be as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF
ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies
of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not
exceed the purchase price of the component upon which liability is
based. In no event shall OMEGA be liable for consequential, incidental
or special damages.
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Cleaning
Periodically wipe the case with a damp cloth and deter-
gent, do not use abrasives or solvents.
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow
Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
*Software Operation manual is in the Software disk.
MIN: 0001 minutes
(9) “[OFS]” Button (Thermocouple offset ad-
just)
When the main display input is T1 and a thermocouple
is connected, the instrument can adjust the offset of the
thermocouple. The same can be done for T2 when on
the main display. In the setup mode, press this button
to enter the thermocouple Offset Setup Function (OFS)
and the indicator CAL should be displayed on the
top-right of the LCD and the current setting is also
shown. Press the number buttons printed in white on
the overlay to change the offset of the thermocouple.
The resolution of the setup is 0.1°. Press the “-” button
to set a negative value. Press the overlay “ENTER”
button to confirm. MAX: ±1999.9 °C/°F.
(12) “[TIME]” Button (System time setting)
To set the system time, press the [TIME] button in the
setup mode. The third display should show the current
date and time with the year flashing. Enter the new
value from left to right in the following format
YY:MM:DD and HH:MM:SS. Press the number but-
tons printed in white on the overlay to set the system
date and time. Press the “ENTER” button to confirm.
Exit this function by pressing ESC button.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor
shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used
in or with any nuclear installation or activity; or (2) in medical applications or
used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in
any way, OMEGA assumes no responsibility as set forth in our basic
DISCLAIMER language, and, additionally, purchaser will
indemnify OMEGA and hold OMEGA harmless from any liability or damage
whatsoever arising out of the use of the Product(s) in such a manner.
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
WARRANTY
/
DATA ACQUISITION
RETURN REQUESTS / INQUIRIES
Data Acquisition & Engineering Software
Communications‐Based Acquisition Systems
Plug‐in Cards for Apple, IBM & Compatibles
Datalogging Systems
Direct all warranty and repair requests / inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO
OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN
ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any
correspondence.
Recorders, Printers & Plotters
The purchaser is responsible for shipping charges, freight, insurance and
proper packaging to prevent breakage in transit.
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
FOR WARRANTY RETURNS,
please have the following
information available BEFORE
contacting OMEGA:
1. Purchase Order number under
which the product was
FOR NON-WARRANTY
REPAIRS, consult OMEGA for
current repair charges. Have the
following information available
BEFORE contacting OMEGA:
1. Purchase Order number to cover
the COST of the repair,
Laboratory Heaters
PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific 3. Repair instructions and/or specific
problems relative to the product. problems relative to the product.
2. Model and serial number of the
product, and
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
OMEGA’s policy is to make running changes, not model changes, whenever
an improvement is possible. This affords our customers the latest in tech-
nology and engineering.
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen
Instruments
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2007 OMEGA ENGINEERING, INC. All rights reserved. This
document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in
part, without the prior written consent of OMEGA ENGINEERING, INC.
Made in Taiwan
Download from Www.Somanuals.com. All Manuals Search And Download.
|