Omega Marine Instruments DP18 RT1 User Manual

An OMEGA Te ch n o lo gie s Co m p a n y  
DP18 Series  
Model DP18-RT1  
True RMS Ammeter  
INSTRUCTION  
SHEET  
M2107/1294  
True RMS Ammeter for current transformer X/5  
3½DIGITSACAMMETER,TRUE-RMSVALUES,WITHSELECTABLERANGESONTHESIGNALCONDITIONERBYPLUG-INJUMPERS.THE  
READINGCANNOTBEMODIFIEDINENGINEERINGUNITS,UNLESSTHEAMPLIFIERISMODIFIED.THEREFOREUSINGTHESTANDARD  
AMPLIFIERTHEDISPLAYWILLSHOWTHEVALUESINDICATEDONTHETABLE.THEINPUTALLOWSDIRECTCONNECTIONTOACURRENT  
TRANSFORMER(CT)WITHA5Aac.SECONDARY,WITHOUTNEEDFORANINTERMEDIATESTEPDOWN.  
FRONTVIEW  
FIG. 1  
SPECIFICATIONS  
½
DISPLAYS . . . . . . . . . . . . . . . . . . . . . .  
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . 0.56" (14.2 mm.)  
SYMBOLS . . . . . . . . . . . . . . . . . . . . . . 1.8.8.8  
3
digits, 7 segment, red LED  
DECIMALPOINTS . . . . . . . . . . . . . . . . Selectable by jumpers  
OVERRANGEINDICATION . . . . . . . . . Display flashes 1999  
SPAN  
OFFSET  
INPUTCONFIGURATION . . . . . . . . . . . Bipolar single  
ZERO . . . . . . . . . . . . . . . . . . . . . . . . . Automatic  
SPANADJUSTMENT . . . . . . . . . . . . . . ± 5 %  
SPAN:ADJUSTTHEMAXIMUMREADING.  
OFFSET:NOTINSERVICE  
SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR.  
CONVERTER . . . . . . . . . . . . . . . . . . . . Dual-slope, average value  
SIGNALINTEGRATIONPERIOD . . . . . 80 ms.  
REARVIEW  
READRATE . . . . . . . . . . . . . . . . . . . . 3.12 / sec.  
RANGES . . . . . . . . . . . . . . . . . . . . . . . See table selection fig. 3  
HOLD . . . . . . . . . . . . . . . . . . . . . . . . . Optional  
Setpoint R1  
(option)  
Setpoint R2  
(option)  
FIG. 2  
Isolated digital output  
(option)  
NOISEREJECTIONNMR . . . . . . . . . . . 50 dB. 50/60 Hz.  
ACCURACY . . . . . . . . . . . . . . . . . . . . 0.2 % ± 1 count  
WARMUPTORATEDACCURACY . . . 2 minutes  
SPANTEMPCO . . . . . . . . . . . . . . . . . . 150 ppm.  
ZEROTEMPCO . . . . . . . . . . . . . . . . . . 2.5 µV/°C.  
D
C
B
A
SIGNAL  
INPUT  
1
10  
OPERATINGTEMPERATURE . . . . . . . 0 to 50 °C (32 to 122 °F)  
STORAGETEMPERATURE . . . . . . . . . -40 to 80 °C (-40 to 176 °F)  
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . 310 gr. (0.68 lb)  
CASEMATERIAL . . . . . . . . . . . . . . . . ABS, DIN 43700, black color  
STANDARDPOWER . . . . . . . . . . . . . . 115 Vac. ± 10 %, 50/60 Hz.  
POWERCONSUMPTION . . . . . . . . . . . 5.5 VA for AC.  
+
ANALOG OUTPUT  
(OPTION)  
-
HOLD, latch the reading  
display, while these pins  
are linked  
POWERSUPPLY  
see instrument label  
ELECTRICALCONNECTIONS . . . . . . . Push-in cable connectors  
BURN-IN . . . . . . . . . . . . . . . . . . . . . . . 24 h.  
RANGESELECTION  
FIG. 3  
D
F
B
IC2  
A
C
E
G
C
B
A
SIGNALINPUT  
5 Aac.  
SIGNALCONDITIONER  
COMPONENTSVIEW  
S1SELECTOR  
I NOMINAL  
Amp.AC  
READING  
Amp.AC  
RESOLUTION  
Amp.AC  
I NOMINAL  
READING  
RESOLUTION  
CLOSE  
CLOSE  
PLACETHEPLUG-INJUMPERONTHE  
SELECTOR S1, IN FUNCTION OF THE  
Amp.AC  
Amp.AC  
JUMPER  
Amp.AC  
JUMPER  
NOMINAL  
TRANSFORMER, AND THE DECIMAL  
POINT JUMPER ON THE  
CORRESPONDINGPOSITION(FIG. 5).  
TO OBTAIN THE INDICATED PERFOR-  
CURRENT  
0.1  
5
5.00  
F
150  
400  
150.0  
400  
B
0.01  
10  
10.00  
C
G
15  
40  
15.0  
40.0  
50.0  
60.0  
75.0  
100.0  
B
G
F
500  
600  
500  
600  
F
E
D
C
B
A
MANCE,  
USE  
CURRENT  
TRANSFORMERS CLASS 0.5 OR  
BETTER  
50  
750  
750  
0.1  
1
60  
E
D
C
1000  
1500  
2000  
1000  
1500  
1999  
75  
100  
CCD1294APC2BA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Ventilation Hood DA 400 User Manual
Milwaukee Sander 48 09 0300 User Manual
Oki Printer 8c Plus User Manual
Oki Printer 8w Lite User Manual
Omega Vehicle Security Switch PSW141 series User Manual
Palsonic Stereo System PMCL 521 User Manual
Panasonic Cordless Telephone KX TG2570B User Manual
Panasonic Digital Camera AJ HC1500G User Manual
Panasonic Ventilation Hood FV 11VH2 User Manual
Paradyne Network Card 916x User Manual