MADE IN
User’s Guide
Shop online at
omega.com
e-mail: [email protected]
For latest product manuals:
omegamanual.info
OS1592
Infrared Fiber Optic
Thermometer/Transmitter
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal two (2) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
FOR NON-WARRANTY REPAIRS, consult OMEGA
for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
1. Purchase Order number to cover the COST
of the repair,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of
Contents
OS1592 Infrared Fiber Optic Thermometer/Transmitter
TABLE OF CONTENTS
SECTION..................................................................PAGE
Section 1 Introduction ........................................................................ 1
Section 2 Installation ........................................................................... 1
2.1 Unpacking.............................................................................. 1
2.2 Electrical Connection............................................................ 3
Section 3 Operation .............................................................................. 4
3.1 Changing the Temperature from °F or °C (or vice versa) ... 5
3.2 Turning on the Display Backlight ...................................... 5
3.3 Using the Alarm Function .................................................. 5
3.4 Analog Output vs. Temperature ........................................ 5
3.5 Resetting Temperature Values ............................................ 6
Section 4 Specifications ....................................................................... 9
Section 5 Maintenance ....................................................................... 11
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of
Figures
OS1592 Infrared Fiber Optic Thermometer/Transmitter
TABLE OF FIGURES
FIGURE ..................................................................PAGE
1 OS1592 Main Unit ............................................................................ 3
2 Power Supply and Analog Output Connections........................... 3
3 Visual Functional Flow Chart .......................................................... 4
4 NEMA-4 Aluminum Enclosure ....................................................... 6
5 Optical Lens Assembly (L1) .25" @ 8" FOV .................................... 7
6 Optical Lens Assembly (L1) .19" @ 20" FOV .................................. 7
7 Optical Lens Assembly (L1) .076" @ 6" FOV .................................. 7
8 Ceramic Tip Assembly (L2) .............................................................. 7
9 Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting ...... 8
10 Optical Head, Mounting Bracket, OS1592-MB ............................. 8
11 Air Purge Collar, OS1592-AP ........................................................... 8
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
1
OS1592 Infrared Fiber Optic Thermometer/Transmitter
INTRODUCTION
The new OS1592 series Infrared Fiber Optic Thermometer/Transmitter
provides non-contact temperature measurement for industrial
applications. The unit measures temperature starting at 260°C (500°F)
and up to 2482°C (4500°F). It provides dual analog outputs (4-20 mA, 0-5
VDC, 0-10 VDC, 1 mV/Deg, J & K type T/Cs) electrically isolated from
the main input DC power supply. The 1 mV/Deg analog output is
standard on all units.
The main electronics is in a NEMA-4 rated Die cast Aluminum housing,
with a local backlit LCD, built-in Relay, Alarm LED, and a 4 position
programmable keypad.
The unit accommodates any of the following assembly types:
• Optical Assembly
• Ceramic Tip Assembly
• Polymer Bolt Assembly
INSTALLATION
2.1 Unpacking
Remove the packing list and verify that you have received all your
equipment. If you have any questions about the shipment, please call
Customer Service at
1-800-622-2378 or 203-359-1660. We can also be reached on the internet:
www.omega.com
e-mail: [email protected]
When you receive the shipment, inspect the container and equipment for
any signs of damage. Note any evidence of rough handling in transit.
Immediately report any damage to the shipping agent.
NOTE:
The carrier will not honor any damage claims unless all the shipping materials are saved for
inspection. After examination and removing contents, save packing material and carton in the
event reshipment is necessary.
The following items are supplied in the box:
• OS1592 Infrared Fiber Optic Thermometer/Transmitter
• The corresponding Optical Assembly
• User’s Manual
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2
OS1592 Infrared Fiber Optic Thermometer/Transmitter
The following describes the ordering information:
To Order ( Specify Model Number )
Model No.
Temperature Range
Optical Assy (Spot Size)
Length
Cable
OS1592-L1-R1-1-* 260/538°C (500 to 1000°F)
Lens Probe 6.3 mm (0.25") @ 20.3 cm (8") 1.52 m (5')
OS1592-L2-R1-*
OS1592-L3-R1-*
260/538°C (500 to 1000°F)
260/538°C (500 to 1000°F)
Ceramic Tip, 15.2 cm (6") Probe
Polymer Bolt, 10.2 cm (4") Probe
1.52 m (5')
1.52 m (5')
1.52 m (5')
OS1592-L1-R2-1-* 538/1093°C (1000 to 2000°F) Lens Probe 6.3 mm (0.25) @ 20.3 cm (8")
OS1592-L1-R2-2-* 538/1093°C (1000 to 2000°F) Lens Probe 4.8 mm (0.19") @ 50.8 cm (20") 1.52 m (5')
OS1592-L1-R2-3-* 538/1093°C (1000 to 2000°F) Lens Probe 1.9 mm (0.076") @ 15.2 cm (6") 1.52 m (5')
OS1592-L2-R2-*
OS1592-L3-R2-*
538/1093°C (1000 to 2000°F) Ceramic Tip, 15.2 cm (6") Probe
538/1093°C (1000 to 2000°F) Polymer Bolt, 10.2 cm (4") Probe
1.52 m (5')
1.52 m (5')
OS1592-L1-R3-2-* 1093/2482°C (2000 to 4500°F) Lens Probe 4.8 mm (0.19") @ 50.8 cm (20") 1.52 m (5')
OS1592-L1-R3-3-* 1093/2482°C (2000 to 4500°F) Lens Probe 1.9 mm (0.076") @ 15.2 cm (6") 1.52 m (5')
The unit provides two separate analog outputs. The first is 1mV/Deg
(Standard). The second analog output to be specified as follows :
- * , where,
- mA , 4-20 mA output
- V1, 0/5 VDC output
- V2, 0/10 VDC output
- K, Thermocouple output, K type (For R1 & R2 Temperature range only)
- J , Thermocouple output, J type (For R1 Temperature range only)
There are three temperature ranges:
R1 – 260 to 538 ºC (500 to 1000 ºF)
R2 – 538 to 1093 ºC (1000 to 2000 ºF)
R3 – 1093 to 2482 ºC (2000 to 4500 ºF)1
Accessories
Model No.
OS1500-BLS
OS1500-BLF
OS1500-RC
PSU-93
Description
Backlight Source
Backlight Fiber Assembly to use with OS1500-BLS
Replacement Bulb
Unregulated 24 VDC Power Supply
Mounting Bracket
Air Purge Collar for -1 & -2 Lens probe
6.3 mm (.25") @ 20.3 cm (8") (-1 probe)
4.8 mm (.19") @ 50.8 cm (20") (-2 probe)
OS1592-MB
OS1592-AP1
OS1592-AP2
Air Purge Collar for -3 Lens probe
1.9 mm (.076") @ 15.2 cm (6")
2
Download from Www.Somanuals.com. All Manuals Search And Download.
2
OS1592 Infrared Fiber Optic Thermometer/Transmitter
2.2 – Electrical Connection
Attach the optical assembly to the optical adapter located on the side of
the housing. Refer to Fig. 1 for the overall appearance of the unit.
Open the cover of the aluminum housing. Slide your cable through the
metal feed thru and connect the wires to the 9 position terminal block
(J101) as shown in Fig. 2. Depending on the type of the analog outputs,
you need to make the proper connection. Connect the shield of the cable
to the inside of the metal feed thru to minimize RF noise.
In order to use the Backlight source OS1500-BLS, disconnect the fiber
optic assembly from the main electronic unit and connect to the light
source. The focused light through the fiber optic assembly provides the
positioning of the optical assembly on the target. After the positioning,
reconnect the fiber optic assembly back to the main unit.
ALARM LED
INDICATION
FIBER OPTIC
THERMOMETER
®
MODE
SET
HAL
°F
ALARM
°F–°C
OS1590 SERIES
CURRENT
TEMPERATURE
4 POSITION
MEMBRANE
KEYPAD
MODEL & S/N
Figure 1 - OS1592 Main Unit
9
RELAY/NO
RELAY
RELAY/NC
CONTACTS
RELAY/COM
–
4/20mA
+
mA
ANALOG
OUTPUTS
1mV/Deg
+
mV
+
0/5VDC, 0/10VDC
J & K T/C
V/TC
–
+
POWER
SUPPLY
18-36VDC
1
J101
Figure 2 - Power Supply and Analog Output Connections
3
Download from Www.Somanuals.com. All Manuals Search And Download.
3
OS1592 Infrared Fiber Optic Thermometer/Transmitter
OPERATION
Table 1 shows all the display modes of the model OS1592, as well as all
the functions of the membrane keypad. Fig 3 shows the Visual Functional
flow chart of the display.
DISPLAY
MODE:
Display shows:
MODE
SET
Press
to...
Press
to...
Press
or
to...
°F–°C
Current temperature
Emissivity
__ __ __
Go to
Set emissivity
Current temperature
Maximum temperature
Go to
Go to
Press to change
°F–°C
Reset
Max, Min, Dif,
temperatures
between °F/°C
Current temperature
Minimum temperature
Press to turn LCD
Current temperature
Differential temperature
Go to
Go to
backlighting ON and OFF
Activate/Deactivate
Set
Current temperature
High alarm setpoint
High alarm value
Table 1 - Functional Flow Chart
DISPLAY MODES
°F
MODE
☞
°F
MODE
☞
°F
MODE
☞
°F
MODE
☞
HAL
°F
MODE
☞
Figure 3 - Visual Functional Flow Chart
4
Download from Www.Somanuals.com. All Manuals Search And Download.
3
OS1592 Infrared Fiber Optic Thermometer/Transmitter
NOTE:
The Emissivity setting as well as the temperature Engineering unit (°F or °C) are
stored in the non-volatile memory. Removing the main power will not erase or
change these settings.
3.1 - Changing the Temperature from °F to °C (or vice versa)
MODE
Press the
Press the
key to go to either the MAX , MIN, or DIF display mode.
key to change the temperature display from °F to °C or vice
°C
versa. The°Fa– nalog output 1 (1 mV/Deg) also follows the temperature
display unit.
3.2 - Turning on the Display Backlight
MODE
Press the
Press the
key to go to either the MAX, MIN, or DIF display mode.
key to turn the display backlight ON or OFF.
3.3 - Using the Alarm Function
MODE
1. Press the
key to go to the HAL display mode.
2. Press either the
or
keys to set the high alarm value.
SET
3. Press the
key to enable the high alarm function. The
icon
appears on the display.
If the temperature exceeds the high alarm set point, the unit goes into
an alarm condition. The
icon on the display flashes, the alarm red
LED turns on, and the internal relay energizes. The relay contacts are
brought out to the terminal block J101 for ease of access.
SET
4. To disable the high alarm function, press the
key again, and the
icon disappears.
NOTE:
1- The alarm temperature value as well as the alarm status are stored in the non-
volatile memory. As a result, removing main power will not erase or change these
settings.
2- The alarm deadband is 10°C or 18°F.
3.4 - Analog Output vs. Temperature
The following equations relate the analog outputs of 4-20mA, 0/5VDC,
0/10VDC to measured temperature:
mA Output – 4
16
4-20mA:
Measured Temperature = (
) x (T2 - T1) + T1
[
]
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3
OS1592 Infrared Fiber Optic Thermometer/Transmitter
Voltage Output
5
0-5VDC:
Measured Temp = (
) x (T2 - T1) + T1
[
]
Voltage Output
0-10VDC: Measured Temp = (
) x (T2 - T1) + T1
[
]
10
Where,
T1 is the minimum temperature range
T2 is the maximum temperature range
3.5 - Resetting Temperature Values
The calculated temperature values (Min, Max, and Diff) can be reset at
SET
any time by pressing the
key in either the MAX, MIN, or DIF display
modes. This will reset the calculated temperatures as follows:
MAX = Current Temperature
MIN = Current Temperature
DIF = 0
After the reset, the unit starts to keep track of the Maximum, Minimum,
and Differential temperatures.
The following figures show the Main Housing, Optical Assemblies,
Mounting Bracket, and Air purge Collar.
89.99
(3.543)
Dimensions mm (in.)
77.90
5.72 (0.225) DIA.
(3.067)
(4) HOLES
71.93
(2.832)
5.08 (0.20)
77.09
(3.035)
115
(4.535)
103
(4.057)
59.72
(2.351)
51.31
(2.020)
9.78 (0.385) DIA. x
47.50 (1.870) DEEP
(2) PLACES
COVER
MAIN HOUSING
Figure 4 - NEMA-4 Aluminum Enclosure
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3
OS1592 Infrared Fiber Optic Thermometer/Transmitter
FIBER
19 (.75) DIA.
Dimensions mm (in.)
25.4
(1.00)
DIA.
111
(4.38)
159
(6.25)
Figure 5 - Optical Lens Assembly (L1) .25" @ 8" FOV
FIBER
19 (.75) DIA.
25.4
(1.00)
DIA.
111
(4.38)
Dimensions mm (in.)
149
(5.87)
Figure 6 - Optical Lens Assembly (L1) .19" @ 20" FOV
FIBER
19 (.75) DIA.
25.4
(1.00)
DIA.
183
(7.22)
Dimensions mm (in.)
264
(10.38)
Figure 7 - Optical Lens Assembly (L1) .076" @ 6" FOV
FIBER
6.35 (.250) DIA.
4.8
(.190)
DIA.
12.7
(.50)
Dimensions mm (in.)
46
(1.812)
152
(6.00)
Figure 8 - Ceramic Tip Assembly (L2)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
3
OS1592 Infrared Fiber Optic Thermometer/Transmitter
72
(2.84)
7.8 (0.307)
7.7 (0.305)
11 (0.414)
10 (0.412)
FIBER
45°
12.7
5.3 (0.209)
(0.50)
15.7 (0.62)
ACROSS FLATS
1/2-20 UNF-2A
5.6 (0.219)
25.4 1.5
(1.00 .06)
11 (0.438)
12.7 1.5
(.50 0.06)
FULL THREAD
53 1.5
102 1.5
4.00 0.06
(2.10 0.06)
Dimensions mm (in.)
AIR PURGE FITTING
6.35
(0.25)
Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting
o
o
.156 TOP LIP
6-32 UNC
25.4 (1.00)
44.5
(1.75)
12.7 (1/2) DEEP FROM
3.3 (0.13) SLOT
15.7
(0.62)
6.35
(0.25)
7.62 (0.30)
44.5
(1.75)
25.4
(1.00)
3.3 (0.13)
44.5
(1.75)
19
(0.75)
35
(1.38)
30°
44.5 (0.75)
Dimensions mm (in.)
R 17.0 (0.67)
24.6 (0.97)
6.35 (0.25)
4.8 (0.19)
17.5
(0.69)
Figure 10 - Optical Head, Mounting Bracket OS1592-MB
AIR PURGE INLET (1/8 NPT)
31.8
(1.25) DIA.
L
Dimensions mm (in.)
MODEL
L
OS1592-AP1
OS1592-AP2
114.3 mm (4.5")
185.4 mm (7.3")
Figure 11 - Air Purge Collar
8
Download from Www.Somanuals.com. All Manuals Search And Download.
4
OS1592 Infrared Fiber Optic Thermometer/Transmitter
SPECIFICATIONS
Temperature Range
R1
R2
R3
260 to 538°C (500 to 1000°F)
538 to 1093°C (1000 to 2000°F)
1093 to 2482°C (2000 to 4500°F)
1% of Rdg.
Accuracy at 22°C (72 °F)
ambient temperature
and at Emissivity of
0.95 or greater
Repeatability
Resolution
0.5% of Rdg
1°C or 1°F
Response Time
Spectral Response
Emissivity
25 msec (0 to 63% of Final value)
0.8 to 1.8 microns
0.05 to 1.00 in 0.01 increments
Set via Keypad
Optical Assemblies
1- Lens Probe (L1-1)
Spot Size (D:S)
Fiber Bundle
6.3 mm @ 203 mm (0.25" @ 8"), (32:1)
1.8 mm (0.070")
Dimensions
25.4 mm (1") OD. x 159 mm (6.25") L
2- Lens Probe (L1-3)
Spot Size (D:S)
Fiber Bundle
1.9 mm @ 152 mm (0.076" @ 6"), (79:1)
1.8 mm (0.070")
Dimensions
25.4 mm (1") OD. x 264 mm (10.38") L
3- Lens Probe (L1-2)
Spot Size (D:S)
Fiber Bundle
4.8 mm @ 508 mm (0.19" @ 20"), (105:1)
0.5 mm (0.020")
Dimensions
25.4 mm (1") OD. x 149 mm (5.87") L
4- Ceramic Tip (L2)
152.4 mm (6") Probe
Fiber Bundle
1.8 mm (0.070")
Dimensions
.48 mm (0.190") OD. x 152.4 mm (6") L
5- Polymer Bolt (L3)
101.6 mm (4") Probe with air purge fitting
Fiber Bundle
1.8 mm (0.070")
Dimensions
12.7 mm (0.5") OD. x 101.6 (4") L
Included at 90° Angle
Air Purge Fitting
Fiber Optic Cable
Power
152.4 cm (5 Feet) Long, Standard
18 to 36 VDC
Operating Ambient Temperature
Electronic Unit
0 to 50°C (32 to 122°F)
0 to 150°C (32 to 302°F)
Optical Assembly
Operating Relative Humidity Less than 95% without condensation
9
Download from Www.Somanuals.com. All Manuals Search And Download.
4
OS1592 Infrared Fiber Optic Thermometer/Transmitter
Display
Backlit LCD dual display
Keypad switch
Electrical Isolation
4 position, tactile feed back membrane
Between Input supply and Analog
outputs, 1000 VAC
Calculated Temperature
values
Maximum (MAX), Minimum (MIN)
and Differential (DIF), Reset via keypad
High Alarm
LED & Display Icon indication
Set & enabled via Keypad
Alarm set point
0 to 100%, set via keypad
10°C or 18°F
5A @ 28 VDC
Alarm Deadband
Relay Contact rating
Analog Outputs
1-1 mV/°F or °C
Standard
6 mV
Accuracy
2-4/20 mA
Accuracy
Optional, -mA
0.25% of Full Scale
350 Ohms
Max. Load
3-0/5 VDC
Accuracy
Min. Load
Optional, -V1
0.25% of Full Scale
250 Ohms
4-0/10 VDC
Optional, -V2
0.25% of Full Scale
750 Ohms
Accuracy
Min. Load
5-J type Thermocouple
500 to 1000°F Range (R1)
Accuracy
6-K type Thermocouple
500 to 1000 °F Range (R1)
1000 to 2000 °F range (R2)
Accuracy
Optional, -J
7°F, Cold Junction compensated
Optional, -K
7°F , Cold Junction compensated
Air Purge Collar
OS1592-AP1
For -1 & -2 Lens Probes
6.3 mm (0.25") @ 203 mm (8") and
4.8 mm (0.19") @ 508 mm (20") FOVs
For -3 Lens Probe
OS1592-AP2
1.9 mm (0.076") @ 152 mm (6") FOV
Main Housing
Dimensions
Die cast Aluminum, NEMA-4 & IP-68
89 W x 114.3 L x 56 mm H
(3.5" W x 4.5" L x 2.2" H)
Weight
500 g (1.1 lbs)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
5
OS1592 Infrared Fiber Optic Thermometer/Transmitter
MAINTENANCE
Routine maintenance is not required except for periodic re-calibration,
occasional inspection of the input and output ends of the fiber assembly
for cleanliness, and a check for broken fibers if damage is suspected.
The optical fibers will provide satisfactory service indefinitely if handled
with normal care. Although the fibers are protected by a steel jacket, they
can be damaged if the jacket is stretched, twisted, shocked or tightly bent
to a small radius. The ends should be protected from damage,
contaminants, and temperatures above 371°C (700°F). OMEGA does not
warrant broken or damaged fibers due to mishandling.
Fiber or lens damage or contamination should be suspected if there is a
sudden change in the calibration of the unit.
Dust and particles on the lens or on the output end of the fiber bundle
may be removed by use of an air jet or a soft brush. Dirt films and other
accumulations should be removed by the use of soft cotton or a Q-tip
moistened with Windex, triple-distilled alcohol or other grease-free and
solids-free solvent. A final wiping with dry cotton is recommended.
If the fiber bundles are to be removed from the detector head assemblies
for extended periods, the fiber bundle receptacles in the head should be
taped or capped to prevent the entry of foreign matter.
A periodic check of the electrical ground connection can be helpful in
preventing RF-pickup problems.
Fiber cables are not interchangeable, as a fiber optic cable assembly is
calibrated with the electronic unit as a system.
There is a gain adjustment for the fiber optic cable assembly inside the
electronic box. This gain adjustment will compensate for any small shift in
temperature reading due to aging of the fiber optic cable over time. Open
the front cover of the Electronic Box. There is a small plug-in PC board
with a potentiometer on one side. This potentiometer provides the gain
adjustment for the fiber optic cable.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum
Safety Warnings and IEC Symbols
This device is marked with international safety and hazardous symbols in
accordance with IEC1010. It is important to read and follow all the precautions
and instructions in this manual before operating or commissioning this device as
it contains important information relating to safety and EMC. Failure to follow
all the safety precautions may result in injury and or damage to your equipment.
IEC Symbol
Description
Caution - Refer to the accompanying
document(s).
Direct Current
Frame or Chassis
Caution and Safety Information
• If the equipment is used in a manner not specified in this manual, the
protection provided by the equipment may be impaired.
• The installation category is one (1).
• There are no user replaceable fuses in this product.
• The output terminals of this product are for use with equipment (digital
meters, chart recorders, etc,) which have no accessible live parts. Such
equipment should comply with all the applicable safety requirements.
• Do not operate the equipment in flammable or explosive environments.
• All connections to the thermometer should be made via a shielded cable, 24
AWG stranded wire with the following ratings: 300V, 105°C (221°F), PVC
insulation.
• Power must be disconnected before making any electrical connections.
• The power supply used to power the thermometer should be VDE or UL
approved with the following ratings: 12 to 24vdc @150mA with overload
protection of 500mA.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Ⅺ
ߜ Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Ⅺ
ߜ Recorders, Printers & Plotters
HEATERS
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Ⅺ
ߜ Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M3672/0905
Download from Www.Somanuals.com. All Manuals Search And Download.
|