1. Hardware Checklist............................................................................3  
2. General Information...........................................................................4  
3. Communicating with your Logger ...................................................5  
4. Quick Start Example..........................................................................8  
5. Download Process Explained.........................................................12  
6. Menu and Navigation.......................................................................13  
7. Connections.....................................................................................15  
8. Accessories......................................................................................17  
9. Specifications...................................................................................19  
After reading this guide please re-  
fer to the Help contents within  
OMEGALOG® (press F1) for fur-  
ther details on your logger and  
how to use it with the software.  
28923  
Version 1.2 - October 08  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Hardware Checklist  
B
A
D
C
E
H
G
F
A) OM-SQ2020/2040 Logger  
B) CD containing software  
C) User’s Guide (this booklet)  
D) USB Cable (OM-SQ-USB-CABLE)  
E) Mounting bracket/stand for logger  
F) Batteries, 6 x AA  
G) Current shunt resistors for 4 to 20mA inputs, 10R x 4  
(OM-SQ-CS)  
H) Connectors: 6 way x 4 (OM-SQ-TB6), 4 way (OM-SQ-TB4),  
3 way (OM-SQ-TB3), with cable ties  
Note: OM-SQ2040 Logger is supplied with 4 extra 6 way  
connectors as above (OM-SQ-TB6).  
Version 1.2 - October 08  
Page 4  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. General Information  
2.1  
Installing the batteries  
The OM-SQ2020/2040 uses six AA size alkaline batteries located under the remov-  
able cover shown below. To insert new or change the existing batteries:  
1. Open the battery cover by pushing down and sliding as shown.  
2. Insert six AA* batteries, ensuring the correct polarity.  
3. Refit the battery cover  
* It is recommended that all replacement batteries are of the same manufacturer, type  
and condition.  
2.2  
Power indicator  
Battery indicator  
When logging please ensure that the batteries in the unit have sufficient capacity to  
complete the logging task. This can be checked via the battery indicator located in the  
top right of the display.  
HIGH  
LOW  
CAPACITY  
CAPACITY  
External power indicator  
The logger may be powered from an external source (10-18V DC)  
Important: To ensure data protection in the case of an unexpected  
power loss, please ensure that batteries are fitted whilst the unit is  
operational.  
28923  
Version 1.2 - October 08  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Communicating with your Logger  
3.1  
Installing the Software  
For detailed installation instructions please see the supplied ‘Software Installation Guide’  
supplement. For quick installation please see the steps below;  
1. Ensure you have administration rights on the PC you wish to install software on  
2. Ensure any current OMEGA applications are closed  
3. Insert the CD into the CD\DVD drive of your computer and wait for it to autorun*  
4. Follow the on screen installation wizard  
* If after a few minutes autorun has not occurred select the Run option from the Windows  
Start Menu. In the Command Line box, type d:\setup and press enter (where d:\ is your  
CD\DVD drive, modify if required)  
Important: Please ensure the software is installed before connecting the  
OM-SQ2020/2040 data logger.  
3.2  
Connecting your OM-SQ2020/2040 Data Logger  
You can connect to your logger by using one of the following methods;  
1. Serial (RS232), including serial adaptors  
2. USB  
3. Ethernet (where fitted)  
Please see below for more information.  
Serial (RS232)  
For information on using serial adaptors please see the OMEGALOG® help file. If using a  
straight serial (RS232) cable, connect one end to the serial port on the logger and the other  
end to the PC’s serial port. Once connected you are ready to begin communications.  
Version 1.2 - October 08  
Page 6  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USB  
Connect one end of the supplied USB lead to the USB port on the logger and the other end  
to a USB port on the PC.  
On detection of the logger the PC will launch the driver installation wizard.  
Win 2000/XP - During the installation the USB drivers were pre-installed so the wizard will  
automatically locate the driver. On the ‘Found New Hardware Wizard’ select ‘No, not this  
time’ and for all the other screens select ‘Next’ to complete the installation.  
28923  
Version 1.2 - October 08  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Win 98SE - Select Search for the best driver for your device (Recommended), Click  
Next and follow the instructions illustrated below.  
Select Continue Anyway on the Hardware Installation warning which refers to Windows  
Logo testing. Once the driver installation has completed you are ready to communicate to  
your logger.  
If you experience any problems refer to Troubleshooting->20XX USB Drivers in OMEGA-  
LOG® help.  
Ethernet  
Before using the Ethernet connection please read the configuration manual which can be  
found under ‘~\OMEGALOG\Manuals\OM-SQ20XX Inbuilt Ethernet Configuration.pdf’  
where ‘~\OMEGALOG’ is the installation directory of OMEGALOG®. Connect your Ethernet  
network to the Ethernet port on the logger.  
Ethernet is only available when the logger is connected via an external power  
supply.  
Version 1.2 - October 08  
Page 8  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Quick Start Example  
After installing OMEGALOG® an example setfile will be installed within the  
OMEGALOG® installation directory. The example file will log the internal temperature of  
the logger. In order to familiarise yourself with the logger the novice user may find this  
example Setup useful.  
4.1  
Startup OMEGALOG® and Select Logger Type  
Click on the shortcut icon on your desktop to launch OMEGALOG® or select it from  
your start menu. When the OMEGALOG® Assistant is loaded, ensure the correct logger  
Type and communication method is selected.  
Logger type can be viewed from the OMEGALOG® Assistant, if you need to make any  
changes select Logger Selection from the toolbar or run the Communication Wizard.  
(Note: the default communication method is USB and you will need to change this via  
the Communication Wizard if you are using any of the other communication methods).  
4.2  
Synchronise Logger & PC  
It is advisable to start by synchronising the Logger clock with the PC clock. See step 1  
and 2 below:  
Synchronise clocks:  
From the Logger  
Setup screen select  
the Logger Control  
tab.  
From  
OMEGALOG® Assistant  
click on Logger  
Setup.  
Click on Set  
Logger Time to PC  
Time, click OK on the  
confirmation screen.  
28923  
Version 1.2 - October 08  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.3  
Running Quick Start Demo  
®
In the OMEGALOG  
Assistant click ‘Logger  
Setup’ to enter the Logger Setup  
screen. From here open the  
demo setfile using File -> Open  
and select the appropriate file for  
your logger type.  
The Logger  
Setup screen  
is now visible,  
from here you  
will be able to  
set up your  
logging  
requirements.  
Within the  
Actual  
Channels tab  
scroll down the  
Sensor Type  
column to Ref.  
Junction 1.  
This is the  
input you will  
be reading in  
this example.  
The Job  
Description  
can be used to  
describe your  
setup.  
Version 1.2 - October 08  
Page 10  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Click  
Click for  
Click  
Click on  
to send  
setup to  
OMEGA-  
if you  
wish to  
Logger  
Control  
LOG®  
logger  
Assistant.  
meter  
icon to  
and start  
the input  
pause or stop the  
logging. Let the unit  
log for a few  
minutes.  
in Real Time.  
logging process.  
In the Logger  
Control window  
you can view  
relevant  
information on  
the state of the  
logger. To stop  
logging click on  
the stop button.  
To Download the logger  
click on the ‘Download Data’  
icon from the OMEGALOG®  
Assistant.  
28923  
Version 1.2 - October 08  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In this screen you can now download the Data File and invoke the Export Wizard or  
download the Data File via Analysis* (See page 10 for further information).  
The data File is given a unique name  
(e.g. 28162735.D20). An explanation of  
the file name is shown on the right; this  
shows the date and start time  
In this example you will download and view the Data in the Analysis* window. Start by  
selecting the Data File and Graph Data action, then click Download Selected File(s).  
You will be prompted to save the Data file, then the data will be converted for viewing.  
Once the decoding has  
taken place the Analysis File  
Description window will be  
presented, click OK to view  
your Data.  
*Available with OMEGALOG® Plus only.  
Version 1.2 - October 08  
Page 12  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Download Process Explained  
Logger  
Data Files  
Microsoft Excel  
Analysis  
(.d20)  
(.xls)  
(.d20)  
Analysis File  
(Plus Only)  
Data File  
Reader  
in  
Export  
external  
MMC/SD  
card  
OMEGALOG®  
(.csv)  
Comma Separated Values  
The Diagram above shows the download process. Data in the logger is written to the internal  
memory and may be downloaded by OMEGALOG®.  
Before the data can be viewed it must be converted by OMEGALOG® for Analysis or exported  
to .csv or .xls format depending on the PC software being used.  
The conversion process can be performed in one of three ways within OMEGALOG®:  
from OMEGALOG® Assistant->Analysis->Export Data File  
automatically when using the download Data button from OMEGALOG®*  
or from the Logger Data Analysis screen by selecting File->Import Data menu*  
Once the file has been downloaded it can be double clicked to open it with the program specified  
under ‘Tools’, ‘Preferences’, ‘File Association Action’.  
*Available with OMEGALOG® Plus only.  
28923  
Version 1.2 - October 08  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Menu and Navigation  
6.1  
Control Panel  
The illustration below shows the navigation controls in more detail.  
RIGHT  
LEFT  
NAVIGATION  
NAVIGATION  
ENTER/CONFIRM &  
POWER ON  
ESCAPE/BACK  
(reverts to previous  
Menu)  
To use the OM-SQ2020/2040 control panel  
press  
, the opening display will be  
shown (see right). The display timeout is  
preset to 10 seconds, however this can  
be changed by selecting the  
Configuration tab within the Logger Setup  
window of OMEGALOG®.  
Version 1.2 - October 08  
Page 14  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2  
Control panel menu  
Detailed below is a basic explanation of the top menu structure. For more information on  
the whole menu structure please refer to the Help->Help Content->Loggers within  
OMEGALOG®.  
6.3.1 Log Control  
In this menu you can Arm (activate) or  
Disarm (deactivate) the logger.  
6.3.2 Meter  
Here you can view each channel in Real  
Time (at 1-2Hz). Use the enter key to auto  
scroll through the channels.  
6.3.3 Status  
The Status menu gives you access to  
information relating to the logger such as  
memory and power supply voltage. You  
can also override the alarm outputs in  
here.  
6.3.4 Setup  
This contains menus for setting up  
Language, Time & Date and the  
opportunity to store and recall Setups.  
6.3.5 Data Files  
This menu allows you to copy data files to  
an external memory card (if fitted) and  
delete the data files held within the  
loggers memory.  
6.3.6 Tools  
The Tools menu contains maintenance  
type functions such as querying the  
software version of the logger,  
performing a self test and resetting the  
logger.  
28923  
Version 1.2 - October 08  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Connections  
Analog Inputs  
Rear view of  
ANALOG  
Rear view of  
ANALOG  
connectors  
connectors  
NOTE: Blocks G to K as shown above are  
only available on OM-SQ2040 loggers.  
As the wiring configuration is dependant upon the sensor type used, it is displayed in OMEGALOG®  
during the setup. Follow the wiring diagram to attach the required sensor. If you would like to print  
the diagrams in more detail or view at a later stage select ‘File > Print from Logger Setup’.  
The example below shows the actual K type differential thermocouple sensor connected to the OM-  
SQ20XX logger from the wiring diagram to the left.  
Version 1.2 - October 08  
Page 16  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sensor Power Wiring  
High Voltage Input  
Block E  
Block F  
Unregulated Logger  
V1(+ve)  
V1(-ve)  
Negative  
V2(-ve)  
V2(+ve)  
Supply Output  
Regulated 5V Output  
I/O Socket Wiring  
Pin  
Connection  
ALARM  
O/P  
EVENT/STATE  
I/P 1-8  
PIN 1  
1
2
3
4
5
6
7
8
Event/State Input 1  
Event/State Input 2  
Event/State Input 3  
Event/State Input 4  
Event/State Input 5  
Event/State Input 6  
Event/State Input 7  
Event/State Input 8  
Ground  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Alarm Output A  
Alarm Output B  
Alarm Output C  
Alarm Output D  
Auxiliary Output +ve  
Auxiliary Output +ve  
Auxiliary Output -ve  
Auxiliary Output -ve  
Ground  
Ground  
Ground  
Fast Pulse Input 1  
Fast Pulse Input 2  
Slow Pulse Input 1  
Slow Pulse Input 2  
No Connection  
-ve  
+ve  
FAST PULSE  
I/P 1-2  
Auxiliary Output  
Max. 500mA  
SLOW PULSE  
I/P 1-2  
External Memory Card Reader  
The external MMC/SD card slot is located inside the  
battery compartment.  
28923  
Version 1.2 - October 08  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Accessories  
OMEGA Engineering supplies a wide range of accessories to compliment the range of  
OM-SQ2020\2040 data loggers. These include GSM Modem and Ethernet converters and wire-  
less adapter as shown below, all of which allow you to contact any OM-SQ2010 data logger re-  
motely or where no land line exists. All are very easy to install and connect directly to the logger  
via RS232. If you need any further details or wish to make a purchase please contact OMEGA  
Engineering.  
Ethernet  
GSM  
Wireless  
RS232 to Ethernet Converter consisting of adaptor box and modem setup  
Cable. Ethernet configuration software is suitable for Windows 2000 and XP  
only.  
Part No:  
OM-SQ-NET-ADAP  
GSM Modem kit comprising of modem, data logger connection cable, power  
lead and antenna with 3m lead. A data-enabled SIM card will also be required  
from your network service provider.  
OM-SQ-GSM-KIT  
OM-SQ-RF-ADAP  
Wireless Adaptor comprising of an RS232 adaptor for connecting the logger  
to the PC at baud rates up to 115K2 with a range of up to 200 metres using the  
2.4GHz frequency band. The kit is supplied with all connecting leads.  
Note: Power supplies (OM-SQ-UNIV-ADAP) need to be ordered separately  
Version 1.2 - October 08  
Page 18  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part No:  
Software packages for set-up, transfer and data analysis:  
OMEGALOG® Plus  
Provides full data analysis, on-line graphing, meter to Excel and  
export to Excel  
OM-SQ-SOFT-PLUS  
OMEGALOG® Plus Multi-User License  
Unlimited use of OMEGALOG® within a single organization.  
OM-SQ-SOFT-PLUS-LIC  
Calibration Certificates for OM-SQ2020/2040 series (all ranges)  
Note: Test and Calibration Certificates are traceable to National  
Standards  
OM-SQ2010  
OM-SQ2040  
OM-SQ2020-CAL  
OM-SQ2040-CAL  
Power supplies  
100-240V AC 50/60Hz supplied with 3-single fit mains plugs for UK,  
Euro, and US  
As OM-SQ-UNIV-ADAP but supplied with 1m flying lead  
OM-SQ-UNIV-ADAP  
OM-SQ-UNIV-ADAP-1  
Current Shunts  
Pack of 4 precision resistors for 4-20mA analog channels  
OM-SQ-CS  
Cables for connecting data loggers to computers/modems.  
Data Logger to PC serial port  
Data Logger to PC USB port  
OM-SQ-SER-CABLE  
OM-SQ-USB-CABLE  
Terminal blocks  
Plug-in terminal blocks with cable restraint  
3-way  
4-way  
6-way  
OM-SQ-TB3  
OM-SQ-TB4  
OM-SQ-TB6  
28923  
Version 1.2 - October 08  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Specifications  
ANALOG INPUTS  
Basic accuracy (5-45°C): ..............................................± (0.05% readings + 0.025% range)  
Common mode rejection: ...........................................................................................100dB  
Input impedance: ...................................................................................................> 1MOHM  
Linearity: ..................................................................................................................0.0015%  
Series mode line rejection:...........................................................................50/60Hz 100dB  
DIGITAL INPUTS  
Zero input voltage....................................................................... 0 to 0.5V (or shorted input)  
One input voltage..................................................................2.7 to 5V (or open circuit input)  
Input protection......................................will turn on below about -0.5V and above about 6V  
ANALOG-DIGITAL CONVERSION  
Type: ....................................................................................................................Sigma-Delta  
Resolution: .....................................................................................................................24bit  
Sampling rate: ..................................................................Up to 20/100 readings per second  
Note: 100Hz Mode not available on 1F8 models  
ALARM OUTPUTS.......................................................................4 x open drain FET (18V 0.1A Max)  
SENSOR POWER SUPPLY..............................Regulated 5 VDC (50mA) or supply voltage (100mA)  
TIME AND DATE...........................................................................................In built clock in 3 formats  
SCALING DATA.......................................................Displays readings in preferred engineering units  
MEMORY  
Internal: ...............................................................................16Mb (Up to 1,800,000 readings)  
External:....................................................... Up to 256Mb removable MMC/SD memory card  
RESOLUTION.................................................................................................Up to 6 significant digits  
PROGRAMMING/LOGGER SET-UP..................... ..........OMEGALOG® or OMEGALOG® Plus software  
COMMUNICATION.......................................................................................USB 1.1 and 2.0 / RS232  
External options: .......................................................................GSM, Ethernet and wireless  
POWER SUPPLY  
Internal:............................................................................................6*x AA Alkaline batteries  
External: ..........................................10-18VDC Reverse polarity and over-voltage protected  
* Maximum operating temperature for supplied alkaline batteries is 50°C  
Version 1.2 - October 08  
Page 20  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
POWER CONSUMPTION @ 9V  
Sleep mode: ..............................................................................................................<600µA  
Logging: ..............................................................................................................40 - 120mA  
DIMENSIONS AND WEIGHT  
2020 Logger  
Dimensions: ...................................................................................W235 x D175 x H55 mm  
Weight: ............................................................................................................Approx 1.2kgs  
Enclosure material: ...................................................................................................... ABS  
2040 Logger  
Dimensions: ...................................................................................W235 x D175 x H92 mm  
Weight: .............................................................................................................Approx1.5kgs  
Enclosure material:........................................................................................................ABS  
MEMORY MODES (internal only)............................................................Stop when full or overwrite  
DISPLAY AND KEYPAD  
2 line x 20 character LCD  
OPERATING ENVIRONMENT ...................................................................................-30°C to +65°C  
Windows is a registered trademark of Microsoft  
Corporation in the United States and other countries.  
Due to our policy of continuous improvements, specifications may change  
without prior notice.  
OMEGA Engineering believe that all information declared is correct at the time of issue.  
No liability is accepted for errors and omissions.  
28923  
Version 1.2 - October 08  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Personal Notes:  
Version 1.2 - October 08  
Page 22  
28923  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Lawn Mower 82 0632 User Manual
Multiquip Saw TP7X User Manual
Napoleon Fireplaces Indoor Fireplace BGDV42N User Manual
Nilfisk ALTO Carpet Cleaner 571 User Manual
Novatel Wireless Network Router CC208 User Manual
Oki Printer Accessories 41515205 User Manual
Palm PDAs Smartphones IIIc User Manual
Panasonic Computer Monitor AG DVX100B User Manual
Panasonic Network Card 2SA2009G User Manual
Paradyne Network Card 3920PLUS User Manual