SM
Extended Warranty
Program
Shop online at
®
omega.com
e-mail: [email protected]
For latest product manuals:
omegamanual.info
OM-EL-ENVIROPAD-TC
Thermometer With Built-in
Data Logging and Graphing
Download from Www.Somanuals.com. All Manuals Search And Download.
ORDERING INFORMATION
OM-EL-ENVIROPAD-TC
Thermometer with built-in
Data Logging & Graphing
Thermometer with
Built-in Data Logging
& Graphing
OM-EL-ENVIROPAD-TC
FEATURES
• User selectable temperature °C or °F
• Supplied with K-type probe
• On-screen graphing
• Two modes: data logging or spot measurement
• User selectable high & low alarms
• 2.8” color touch screen
• Compatible with thermocouples type J, K, N, & T via mini
thermocouple connection
• Downloadable saved data via USB and viewed using
Excel or similar spreadsheet packages
• Internal rechargeable lithium polymer battery
• Date & time function
• Audible alarm
• Removable protective boot for increased durability
This robust easy to use handheld device takes and records temperature readings via the attached K--type probe supplied with the unit. A
large touch screen, color display indicates temperature, maximum and minimum readings and will produce a graph of the data.
It has two functions - Data Logging and Spot Measurement;
1. When in Data Logging mode, it can be set up and left to take temperature readings at pre-determined intervals for a desired length of
time. All readings are saved to a file with a date and time stamp in CSV format for up to 65,536 readings.
2. When in Spot Measurement mode, the unit can be used as a thermometer to capture one-off temperature readings displayed on
screen. This can be repeated for up to 65,536 readings per file.
®
Data can be downloaded to PC via a USB connection and opened with Microsoft Excel .
The unit is compatible with any J, K, N and T type thermocouple probes. The protective boot can be removed for cleaning and is dishwasher
safe.
Specifications
Minimum
Typical
Maximum
Unit
V d.c.
°C
USB supply voltage
4.5v
-
5.5v
Internal resolution
-
0.1
-
Data recording capacity (per recording)
Hand unit operating temperature range
Operating time (on a single charge)
Displayable temperature (dependant on probe)
Storage capacity
-
65536
+50 (+122)
**
readings
°C (°F)
hrs
0 (+32)
-
8
-100
-
24*
-80 to +1200
+9999
100
°C
-
files
* Typical use: 1min recording rate & power-save
** Depends on recording settings
Warning - Do not exceed operating temperatures
omega.com
Specifications liable to change without prior warning
Issue 01
12/2012
S.L
Applies to OM-EL-EnviroPad-TC
Page 1 of 2
Download from Www.Somanuals.com. All Manuals Search And Download.
OM-EL-ENVIROPAD-TC
Thermometer with Built-in Data Logging & Graphing
HARDWARE
UNIT
• Battery: rechargeable via USB connection
• LCD: color TFT touch-screen
• Integrated memory for logged data
• Single front-panel push-button used for power-switch. Single press=ON, press & hold=OFF.
• 1x thermocouple connector (top of unit)
• 1x micro USB Type B (bottom of unit) for connection of unit to PC via USB cable supplied.
PROBE
• Thermocouple probe: class 1 tolerance, 316 stainless steel probe
• Sealed to IP66
• Themocouple Type: K
Specifications
Minimum
Typical
Maximum
Unit
°C
Probe Temperature Accuracy
Probe Temperature Range*
Handle Temperature Range
-
+/- 1.5
-
-180
-10
-
-
+1300
+125
°C
°C
* Short term measurement
N.B. Any of the above hardware specifications may change without prior warning if new/suitable alternatives become available.
DIMENSIONS
All dimensions in mm (inches)
(2.68)
(0.75)
omega.com
Specifications liable to change without prior warning
Issue 01
10/2012
S.L
Applies to OM-EL-EnviroPad-TC
Page 2 of 2
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC., warrents this unit to be free of defects in materials and workmanship for
a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence
of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or
other operating conditions outside of OMEGA’s control. Components in which wear is not warranted,
include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result
from the use of its products in accordance with information provided by OMEGA, either verbal or
written. OMEGA warrants only that the parts manufactured by the company will be as specified and
free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are
exclusive, and the total liability of OMEGA with respect to this order, whether based on contract,
warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price
of the component upon which liability is based. In no event shall OMEGA be liable for consequential,
incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a
“Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2)
in medical applications or used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes
no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally,
purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever
arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESS-
ING DELAYS). The assigned AR number should then be marked on the outside of the return package and
on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have
the following information available BEFORE
contacting OMEGA.
1. Purchase order number which the product
was PURCHASED,
2. Model and serial number of the product
under warranty, and
FOR NON-WARRANTY RETURNS, consult
OMEGA for current repair charges. Have the
following information available BEFORE contacting
OMEGA.
1. Purchase Order number to cover the COST of
the repair,
2. Model and serial number of the product and
3. Repair instructions and/or specific problems
relative to the product.
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an iimprovement is possible. This
affords customers the latest technoogy and engineering.
OMEGA is a registered tradrmark of OMEGA ENGINEERING, INC.
© COPYRIGHT 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,
photocopied, translated, or reduced to any electronic medium-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Download from Www.Somanuals.com. All Manuals Search And Download.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA... Of Course!
SM
Shop online at omega.com
TEMPERATURE
Thermocouple RTD & Thermister Probes Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermister
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instumentation & Accessories
FLOW/LEVEL
Rotameters Gas Mass Flowmeters & FlowComputers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
PH/CONDUCTIVITY
pH Electrodes Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISTION
Data Acquistion & Engineering Software
Communications-Based Acquistion Systems
Plug-in Cards for Apple, IBM, & Compatibles
Data Logging Systems
Recorders, Printers, & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH Conductivity & Dissolved Oxygen Instruments
M5238/0113
Download from Www.Somanuals.com. All Manuals Search And Download.
|