Confocal Laser Scanning
Biological Microscope
FV1000
FLUOVIEW
FLUOVIEW—Always Evolving
Download from Www.Somanuals.com. All Manuals Search And Download.
Imaging to Analysis
ing up New Worlds
From Imaging to Analysis
FV1000
Advanced Deeper Imaging with High Resolution
FV1000MPE
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Advanced FLUOVIEW Systems Enhance the Power of
Your Research
Superb Optical Systems Set the Standard
for Accuracy and Sensitivity.
Two types of detectors deliver enhanced accuracy and sensitivity,
and are paired with a new objective with low chromatic aberration,
to deliver even better precision for colocalization analysis.
These optical advances boost the overall system capabilities and raise
performance to a new level.
Imaging, Stimulation and Measurement—
Advanced Analytical Methods for Quantification.
Now equipped to measure the diffusion coefficients of intracellular
molecules, for quantification of the dynamic interactions of molecules
inside live cell.
FLUOVIEW opens up new worlds of measurement.
Evolving Systems Meet the Demands of Your Application.
Upgradeable system with optional hardware and software to meet
the demands of your research.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Excellent Precision, Sensitivity and Stability.
FLUOVIEW Enables Precise, Bright Imaging with Minimum Phototox
Main scanner
Barrier filter
Grating
Grating
Laser combiner
LD635
LD559
LD473
LD405
Broadband fiber *
Confocal pinhole
AOTF
AOTF
Broadband fiber
Laser combiner/Fiber
Scanners/Detection
Laser Combiner
Diode Laser
High Sensitivity Detection System
Greater stability, longer service life and
lower operating cost are achieved using
diode lasers.
High-sensitivity and high S/N ratio optical
performance is achieved through the
integration of a pupil projection lens, use
of a high sensitivity photomultiplier tube
and an analog processing circuit with
minimal noise. Enables high S/N ratio
image acquisition with minimal laser power
to reduce phototoxicity.
Laser Feedback Control
Scanner unit is equipped with laser power
monitor for feedback control enhancing
stable laser output.
Two versions available.
•Single fiber-type combiner is used for
main scanner FV1000 with up to six lasers,
ranging from 405 to 635 nm.
•Dual fiber-type combiner is used for laser
light stimulation with main and SIM
scanner FV1000.
Laser Compatibility
Diode laser :
405 nm, 440 nm, 473 nm, 559 nm, 635 nm
Gas laser :
Multi-line Ar laser (458 nm, 488 nm, 515 nm)
HeNe(G) laser (543 nm)
Up to Four PMT Channels
Three integrated confocal PMT detectors,
and optional module with fourth confocal
PMT expandable up to four PMT channels.
Broadband Fiber
Broadband fiber connection for 405–635 nm
lasers, to achieve an ideal point light source
with minimal color shift and position shift
between images.
Spectral Scanning Unit
Filter Scanning Unit
Two Versions of Light Detection System
• Spectral detection for high-precision
spectroscopy with 2 nm resolution.
• Filter detection equipped with high
quality filter wheels.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Technology / Hardware
icity.
SIM Scanner *
* Option
Microscope
PMT
PMT
PMT
Specimen
Galvanometer
scanning mirrors
UIS2 objectives
Galvanometer
scanning mirrors
Pupil
projection
lens
Optical System
Samples and Specimens
Motorized Microscopes
UIS2 Objectives
Supports a Wide Range of Samples and
Specimens
Tissue culture dishes, slide chambers,
microplates and glass slides can be used
with live cells and fixed specimens.
Compatible with Olympus IX81 inverted
microscope, BX61WI focusing nosepiece
and fixed-stage upright microscope, and
BX61 upright microscope.
Olympus UIS2 objectives offer world-
leading, infinity-corrected optics that
deliver unsurpassed optical performance
over a wide range of wavelengths.
High S/N Ratio Objectives with
Suppressed Autofluorescence
Olympus offers a line of high numerical
aperture objectives with improved
fluorescence S/N ratio, including
objectives with exceptional correction for
chromatic aberration, oil- and water-
immersion objectives, and total internal
reflection fluorescence (TIRF) objectives.
IX81
BX61
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Two Versions of Light Detection System that Set New Standards
for Optical Performance.
Spectral Based Detection
Flexibility and High Sensitivity
Spectral detection using gratings
for 2 nm wavelength resolution
and image acquisition matched to
fluorescence wavelength peaks.
User adjustable bandwidth of
emission spectrum for acquiring
bright images with minimal cross-
talk.
EGFP–EYFP Fluorescence Separation
Precise Spectral Imaging
2,600
2,400
The spectral detection unit uses a grating method that offers
2,200
2,000
linear dispersion compared with prism dispersion. The unit
provides 2 nm wavelength resolution to high-sensitivity
1,800
EYFP
1,600
1,400
EGFP
photomultiplier tube detectors. Fluorescence separation can be
1,200
1,000
achieved through unmixing, even when cross-talk is generated
by multiple fluorescent dyes with similar peaks.
800
EGFP (dendrite) — EYFP (synapse)
600
XYλ
400
Wavelength detection range: 495 nm–561 nm in
2 nm steps
496
500
504
508
512
516
520
524
528
532
536
540
544
548
552
Wavelength
Excitation wavelength: 488 nm
Courtesy of: Dr. Shigeo Okabe
Department of Anatomy and Cell Biology,
Tokyo Medical and Dental University
Filter Based Detection
Enhanced Sensitivity
Three-channel scan unit with detection system featuring hard
coated filter base. High-transmittance and high S/N ratio optical
performance is achieved through integration of a pupil projection
lens within the optics, the use of a high sensitivity photomultiplier
and an analog processing circuit with minimal noise.
High-Performance Filters Deliver Outstanding Separation
Special coatings deliver exceptionally sharp transitions to a
degree never achieved before, for acquisition of brighter
fluorescence images.
DM488/543/633 Comparison
100
80
60
40
20
0
480
500
520
540
560
580
600
620
640
660
680
700
Wavelength (nm)
Conventional mirror unit
High-performance mirror unit
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Technology / Hardware
SIM Scanner Unit for Simultaneous Laser Light Stimulation and
Imaging.
SIM (Simultaneous) Scanner Unit
Combines the main scanner with a dedicated laser light
stimulation scanner for investigating the trafficking of fluorescent-
labeled molecules and marking of specific live cells.
Lasers are used for both imaging
and laser light stimulation.
Simultaneous Laser Light Stimulation and Imaging
Performs simultaneous laser light stimulation and imaging to
acquire images of immediate cell responses to
stimulation in photobleaching experiments.
Branching of laser in
laser combiner.
AOTF
LD635
LD559
AOTF
LD473
LD405
Modifiable Stimulation Area During Imaging
Unique "Tornado" Scanning for Efficient Bleaching
The stimulation area can be moved to a different position on the
cell during imaging, providing a powerful tool for photoactivation
and photoconversion experiments.
Conventional raster scanning does not always complete
photobleaching quickly. Tornado scanning greatly improves
bleaching efficiency by significantly reducing unnecessary
scanning.
*Tornado scanning only available for SIM scanner.
Tornado scanning
ROI (region of interest)
scanning
Superfluous scanning areas.
ROI (region of interest) scanning.
Tornado scanning.
Cell membrane stained with DIO, and subjected to both
conventional ROI and tornado scanning.
Wide Choice of Bleaching Modes
Multi-Purpose Laser Combiner
Various scan modes can be used for both the observation area
and stimulation area. Enables free-form bleaching of designated
points, lines, free-lines, rectangles and circles.
All lasers can be used for both Imaging and laser light stimulation.
LD405 / LD635 / AOTF / AOTF / LD473 / LD559
Laser Sharing with Main Scanner
Dual fiber laser combiner provides laser sharing between the SIM
scanner and main scanner, eliminating the need to add a
separate laser for stimulation.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
New Objective with Low Chromatic Aberration Delivers
World-Leading Imaging Performance.
NEW
Low Chromatic Aberration Objective
Best Reliability for Colocalization Analysis
A new high NA oil-immersion objective minimizes chromatic
aberration in the 405–650 nm region for enhanced imaging
performance and image resolution at 405 nm. Delivers a high
degree of correction for both lateral and axial chromatic
aberration, for acquisition of 2D and 3D images with excellent
and reliable accuracy, and improved colocalization analysis. The
objective also compensates for chromatic aberration in the near
infrared up to 850 nm.
Lateral and Axial Chromatic Aberration
Small Degree of
Chromatic Aberration
Large Degree of
Chromatic Aberration
Low Chromatic
PLAPON60xOSC
Aberration Objective Magnification: 60x
NA: 1.4 (oil immersion)
W.D.: 0.12 mm
Chromatic aberration compensation range: 405–650 nm
Optical data provided for each objective.
Objective
Chromatic Aberration Comparison for PLAPON 60xOSC and
UPLSAPO 60xO
Lateral Chromatic Aberration
0.5
Axial chromatic
aberration
(Z direction).
UPLSAPO60xO
Lateral chromatic
aberration (X-Y
direction at FN6).
0.0
PLAPON 60xOSC
Performance Comparison of PLAPON 60xOSC and UPLSAPO 60xO
PLAPON60xOSC
UPLSAPO60xO
-0.5
400
450
650
500
550
600
Axial chromatic
aberration (Z direction)
Wavelength (nm)
*Chromatic aberration values are design values and are not guaranteed values.
Compared for PSF fluorescent
beads (405 nm, 633 nm).
Approx.
0 µm
Approx.
0.5 µm
Lateral chromatic
aberration (X-Y direction)
Improved Flatness and Resolution at 405 nm
Better flatness reduces the number of images for tiling.
Compared for PSF fluorescent
beads (405 nm, 488 nm, 633
nm).
Approx. 0.1 µm
Approx. 0.2 µm
Flatness Comparison Image at 1x Zoom
PLAPON60xOSC
UPLSAPO60xO
3D image
Tubulin in Ptk2 cells labeled with
two colors (405 nm, 635 nm) and
compared.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Technology / Hardware
Exceptional Resolution for Imaging of Cytoplasmic Membrane
and Areas Deep Within Living Specimen.
TIRFM (Total Internal Reflection Fluorescence Microscope) System
Switchable between Confocal and TIRFM Imaging
Switchable between confocal and TIRFM imaging for localization
of proteins on the cytoplasmic membrane surface and acquisition
of sectioning images within cells.
Software Control of TIRF Illumination
Built-in laser provides TIRF illumination. Software can be used to
tune the angle of incidence of excitation light and calculates the
penetration depth of the evanescent wave based on the TIRF
objective used.
High-Numerical Aperture Objectives for TIRF Illumination
A line of high-numerical aperture (NA) objectives is available for
TIRF illumination.
TIRFM
LSM
GFP—Pak—K298A in HeLa cells.
Courtesy of Dr.J M Dong of sGSK-NRP laboratory, Singapore
NEW
NEW
NEW
APON60xOTIRF
NA : 1.49 (oil immersion)
WD: 0.1 mm
UAPON100xOTIRF
NA : 1.49 (oil immersion)
WD: 0.1 mm
UAPON150xOTIRF
NA : 1.45 (oil immersion)
WD: 0.08 mm
Apo100xOHR
NA : 1.65 (oil immersion)
WD: 0.1 mm
(Customized cover glass and
immersion oil)
FV1000MPE Multiphoton Excitation System
Brighter and Deeper Imaging with Finer Resolution
The FV1000 is upgradeable to multiphoton excitation capability
by adding a dedicated laser and multiphoton optical system.
Optical design is optimized for multiphoton principles for brighter
imaging of features deep within living specimens, at higher
resolutions than previously possible.
Special Multiphoton Objective with Outstanding
Brightness and Resolution
Olympus offers a high NA water-immersion objective designed
for a wide field of view, with improved transmittance at near-
infrared wavelengths. A correction collar compensates for
spherical aberration caused by differences between the refractive
indices of water and specimens, forming the optimal focal spot
even in deep areas, without loss of energy density. The objective
is designed to collect scattered light over a wide field of view for
maximum image brightness.
3-dimensionally constructed images of neurons expressing EYFP in the cerebral neocortex of a
mouse under anesthesia.
Courtesy of:
Hiroaki Waki, Tomomi Nemoto, and Junichi Nabekura
National Institute for Physiological Sciences, National Institutes of Natural Sciences, Japan
XLPLN25xWMP
Magnifications : 25x
NA
W.D.
: 1.05 (water immersion)
: 2.0 mm
Multiphoton Laser Light Stimulation
Adding a multiphoton laser to the SIM scanner enables
multiphoton laser light stimulation or uncaging confined to the
focal volume.
* The FLUOVIEW FV1000MPE is a class 4 laser product.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
User-Friendly Software to Support Your Research.
Configurable Emission
Wavelength
Select the dye name to set the optimal
filters and laser lines.
Wide Choice of Scanning Modes
Several available scanning modes
including ROI, point and high-speed
bidirectional scanning.
Image Acquisition by Application
User-friendly icons offer quick access to
functions, for image acquisition according
to the application (XYZ, XYT, XYZT, XYλ,
XYλT).
Time Controller
Precisely synchronizes different
experimental protocols including FRAP,
FLIP and FRET by acceptor photo-
bleaching and time-lapse. Save and open
settings for later use.
Configurable Excitation Laser
Power
Easily adjust the optimum laser power for
each specimen (live cells and fixed
specimens).
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Technology / Hardware
Optional Software with Broad Functionality.
Diffusion Measurement Package
For analysis of intracellular molecular
interactions, signal transduction and other
processes, by determining standard
diffusion coefficients. Supports a wide
range of diffusion analysis using point
FCS, RICS and FRAP.
Multi Stimulation Software
Configure multiple stimulation points and
conditions for laser light stimulation
synchronized with imaging, for detailed
analysis of the connectivity of cells within
the stimulation area.
Re-Use Function
Open previously configured scanning
conditions and apply them to new or
subsequent experiments.
Multi-Area Time-Lapse Software
Multi-Area Time-Lapse
Software control of the motorized XY
stage enables multiple measurement
points in glass slides, 35 mm dishes or
individual microplate wells. Repeated
imaging of multiple cells improves the
statistical power of time-lapse
experiments.
Help Guide
Comprehensive help guide describes the
functions and usage for each command,
and overall sequence of operations.
Mosaic Imaging
A motorized XY stage is programmed with
the use of a high-magnification objective
to acquire continuous images from
adjacent fields of view, to assemble a
single, high resolution image covering a
wide area. Three-dimensional images can
also be assembled using XYZ acquisition.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Broad Application Support and Sophisticated Experiment
Control.
Multi-Color
Imaging
Measurement
3D/4D
Light Stimulation
Volume
Rendering
Multi-
Dimensional
Time-Lapse
Colocalization
FRET
3D Mosaic
Imaging
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Application
Measurement
Diffusion measurement and molecular interaction
analysis.
Light Stimulation
FRAP/FLIP/Photoactivation/Photoconversion/Uncaging.
Multi-Dimensional Time-Lapse
Long-term and multiple point.
3D Mosaic Imaging
High resolution images stitched to cover a large area.
Multi-Color Imaging
Full range of laser wavelengths for imaging of diverse
fluorescent dyes and proteins.
3D/4D Volume Rendering
One-click 3D/4D image construction from acquired
XYZ/T images.
Change the angle of 3D image with a single click.
Colocalization
Configurable threshold values for fluorescence
intensities on the scatterplot.
Accurate colocalization statistics and visualization of
colocalized area on image.
FRET
Configuration wizard simplifies the setting of FRET
experimental procedures.
Optimal laser excitation wavelengths for CFP/YFP
FRET.
2,400
2,200
2,000
1,800
1,600
1,400
1,200
1,000
800
CH1
CH2
CH1
CH2
600
400
200
15,000
20,000
25,000
30,000
Time (ms)
35,000
40,000
Image of variations in calcium concentration of HeLa cells
expressing YC3.60 when stimulated with histamine.
Reference:
Takeharu Nagai, Shuichi Yamada, Takashi Tominaga, Michinori
Ichikawa, and Atsushi Miyawaki 10554-10559, PNAS, July 20,
2004, vol. 101, no.29
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Diffusion Measurement Package
This optional software module enables data acquisition and analysis to investigate the molecular interaction
and concentrations by calculating the diffusion coefficients of molecules within the cell.
Diverse analysis methods (RICS/ccRICS, point FCS/point FCCS and FRAP) cover a wide range of molecular
sizes and speeds.
1.5
1
130
0.5
0
125 Pixels
105
125
105
130
Pixels
RICS—Raster Imaging Correlation Spectroscopy
Raster image correlation spectroscopy (RICS) is a new method for analyzing the diffusion
and binding dynamics of molecules in an entire, single image. RICS uses a spatial
correlation algorithm to calculate diffusion coefficients and the number of molecules in
specified regions.
Cross correlation RICS (ccRICS) characterizes molecular interactions using fluorescent-
labeled molecules in two colors.
point FCS—Point scan Fluorescence Correlation Spectroscopy
point scan fluorescence correlation spectroscopy (point FCS) analyzes intensity
fluctuations caused by diffusion or binding/unbinding interactions of a protein complex.
point FCS uses an auto correlation function to carry out operations on fluorescence
signals obtained by continuous scanning of a single pixel on the screen.
point scan fluorescence cross-correlation spectroscopy (point FCCS) analyzes the
fluctuation of fluorescent-labeled molecules in two colors. The coincidence of fluctuations
occurring in two detection channels shows that the two proteins are part of the same
complex.
point FCS and point FCCS can now be performed with a standard detector, eliminating
the need for a special high-sensitivity detector.
FRAP Analysis
The Axelrod analytical algorithm is installed as a FRAP analysis method. The algorithm is used to calculate diffusion coefficients and the
proportions of diffusing molecules.
Analytical methods
according to molecule
diffusion speeds
Small molecules
in solution
Proteins
in solution
Diffusion of
proteins
in cell
Lateral diffusion
in cell membrane
Protein
trafficking
Molecular complex
formation,
aggregation
> 100
~ 100
1 ~ 100
< 0.1
< 0.01
<< 0.001
point FCS
RICS
Capable range
of measurement
FRAP
Download from Www.Somanuals.com. All Manuals Search And Download.
15
Application/ Molecular Interaction Analysis
RICS Application and Principles
Comparison of Diffusion Coefficients for EGFP Fusion Proteins Near to Cell Membranes and In Cytoplasm
At cytoplasmic membrane
Diffusion coefficient D =0.98 µm /s
In cytoplasm
Diffusion coefficient D =3.37 µm /s
RICS can be used to designate and analyze regions of interest
based on acquired images.
2
2
EGFP is fused at protein kinase C (PKC) for visualization, using
live cells to analyze the translocation with RICS. The diffusion
coefficient close to cell membranes was confirmed to be lower
than in cytoplasm, after stimulation with phorbol myristate
acetate (PMA). This is thought to be from the mutual interaction
between PKC and cell membrane molecules in cell membranes.
In addition to localization of molecules, RICS analysis can
simultaneously determine changes in diffusion coefficient, for
detailed analysis of various intracellular signaling proteins.
Sample image:
HeLa cells expressing EGFP fusion PKC (after PMA stimulation)
RICS Principle
Scan in X-Axis Direction
Molecules of different sizes diffuse at different speeds within
cells. Small molecules move faster, compared with large
molecules that move relatively slowly. The FV1000 acquires
information on the movement of these diffusing fluorescent-
labeled molecules as image data, together with morphological
information about the cell. The image data obtained for each
pixel was sampled at different times, so the data for each pixel is
affected by the passage of time, in addition to its spatial XY
information. By analyzing this image data with a new statistical
algorithm for spatial correlation, the diffusion coefficients and
molecule counts can be calculated for molecules moving within
the cell.
0 µs
10 µs
20 µs
30 µs
40 µs
50 µs
n µs
0 ms
Scan in Y-Axis Direction
0 ms
1 ms
2 ms
3 ms
4 ms
Spatial Correlation Algorithm
When the spatial correlation algorithm is applied between pixels, a higher correlation
is obtained as the speed of movement of the molecule nears the scanning speed.
When calculating the spatial correlation in the X-direction, because the scanning
speed in the X-direction is fast, a higher correlation is obtained for fast-moving
molecules than for slow-moving molecules. When the scanning speed in the Y-
direction is slow, a higher correlation is obtained for slow-moving molecules. RICS
using LSM images scans in both X- and Y-directions, so it can be used to analyze
the movements of a wide range of molecules, both fast and slow.
n ms
Small
Large
Molecule size
RICS Analysis Method
Results of Analysis
(diffusion coefficient and
molecule count)
LSM Image
Spatial Correlation
Theoretical Formula Used
for Fitting Calculation
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Laser Light Stimulation
The SIM scanner system combines the main scanner with a laser light stimulation scanner.
Control of the two independent beams enables simultaneous stimulation and imaging, to capture reactions
during stimulation.
Multi-stimulation software is used to continuously stimulate multiple points with laser light for simultaneous
imaging of the effects of stimulation on the cell.
FLIP—Fluorescence Loss in Photobleaching
Fluorescence loss in photobleaching (FLIP) combines imaging with continuous bleaching of a specific region to observe the diffusion of a
target protein within a cell. The changes in the image over time make it possible to observe the location of structural bodies that inhibit
the diffusion of the molecule.
3,000
2,800
2,600
2,400
2,200
2,000
1,800
1,600
1,400
1,200
1,000
800
600
400
200
0
0
10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
Time (ms)
Specimen: HeLa cell, GFP (free), 488 nm excitation (multi-argon laser)
Image acquisition time: 100 ms/ bleach time: 100 s continuously, 405 nm bleaching
FRAP—Fluorescence Recovery after Photobleaching
Exposure of fluorescent-labeled target proteins to strong laser light causes their fluorescence to fade locally. Fluorescence recovery after
photobleaching (FRAP) is used to observe the gradual recovery of fluorescence intensity caused by protein diffusion from the area
surrounding the bleached region. By examining the resulting images, it is possible to characterize the diffusion speed of the molecule,
and the speed of binding and release between the molecule and cell structures.
Example: Fluorescence recovery without interactions
Example: Fluorescence recovery with interactions
If the protein can freely diffuse, the bleached region recovers
its fluorescence at a high speed due to Brownian motion.
If the protein is strongly bound to a structure or forms part of a
large protein complex, the bleached region recovers its
fluorescence at a slower rate relative to the unbound state.
Time
Time
750
700
650
600
550
500
450
400
350
300
250
Specimen: Hippocampal neurons, Shank-GFP stain, 488 nm excitation (multi-argon laser)
Image acquisition time: 100 ms Bleach time: 80 ms, 488 nm excitation (Sapphire 488 laser)
0
10,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
Time (ms)
Data courtesy of: Dr. Shigeo Okabe
Department of Anatomy and Cell Biology, Tokyo Medical and Dental University
Download from Www.Somanuals.com. All Manuals Search And Download.
17
Application/ Molecular Interaction Analysis
Photoconversion
The Kaede protein is a typical photoconvertible protein, which is a specialized fluorescent protein that changes color when exposed to
light of a specific wavelength. When the Kaede protein is exposed to laser light, its fluorescence changes from green to red. This
phenomenon can be used to mark individual Kaede-expressing target cells among a group of cells, by exposing them to laser light.
450 nm laser light
405 nm
405 nm
Before Stimulation
After Stimulation
Kaede-expressing astroglia cells are stacked on the Kaede-expressing neurons. By illuminating two colonies with a 405 nm laser, the Kaede color can
be photoconverted from green to red. The glial cells in contact with the neurons are observed while they are forming colonies and extending their
processes, and the nuclei of these colonies can also be observed. The SIM scanner FV1000 makes it easy to change cell colors from green to red while
conducting an observation, and to control neutral colors between red and green.
Data courtesy of: Dr. Hiroshi Hama, Ms. Ryoko Ando and Dr. Atsushi Miyawaki, RIKEN Brain Science Institute Laboratory for Cell Function Dynamics
Uncaging
A 405nm laser is optional for uncaging with the SIM scanner system. Caged compounds can be uncaged point-by-point or within a
region of interest, while the main scanner of the FV1000 captures images of the response with no time delay.
2,000
1,900
1,800
1,700
1,600
1,500
1,400
1,300
1,200
1,100
1,000
900
800
700
600
500
0
5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 50,000 55,000
Time (ms)
Caged-Glutamate
Fluorescent calcium indicator Fluo-3 in HeLa cells. Image acquisition at 1-second intervals
Using the caged compound Bhcmoc-Glutamate, an increase in calcium ion concentration inside the cell can be observed in response to
glutamate stimulation, released via 405 nm laser illumination.
Data courtesy of:
Dr. Hiroshi Hama, Dr. Atsushi Miyawaki, RIKEN Brain Science Institute Laboratory for Cell Function Dynamics
Caged compound Bhcmoc-Glutamate presented by Dr. Toshiaki Furuta, Department of Science, Toho University
Multi-Point Laser Light Stimulation
Using multi-stimulation software, the user can configure continuous laser light stimulation of multiple points with simultaneous imaging,
which is effective for applications such as uncaging experiments involving laser light stimulation of several spines in neurons.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
P2
Multi-Dimensional Time-Lapse
P3
P1
The FV1000 can be used for ideal multi-dimensional time-lapse imaging during confocal observation,
using multi-area time-lapse software to control the motorized XY stage and focus compensation.
P4
P5
Significantly Improved Long Time-Lapse Throughput
Equipped with motorized XY stage for repeated image acquisition from multiple points scattered across a wide area. The system
efficiently analyzes changes over time of cells in several different areas capturing, large amounts of data during a single experiment to
increase the efficiency of experiments. Microplates can be used to run parallel experiments, which significantly improves throughput for
experiments that require long-term observation.
Point 2
Point 3
Point 1
Focal Plane 4
Focal Plane 3
Focal Plane 2
Focal Plane 1
Supports repeated image
acquisition from multiple areas in
a single microplate well.
Point 4
Point 5
Multi-Point Time-Lapse Software
Point 6
Focal Drift Compensation for Long Time-Lapse Imaging
The IX81-ZDC Zero Drift Compensation system corrects loss of focus caused by temperature changes around the microscope and other
factors during long time-lapse observation. The thermal drift compensation eliminates the need to take images at several Z planes,
minimizing live cell exposure to irradiation.
Offset
IR Laser for focal
plane detection
Baseline focal plane
Objective
focal
plane
Set target
observation
plane
Over time, the
objective focal
plane drifts from
the observation
plane.
Laser detects
the glass
surface before
imaging.
Immediately
returns to initial
offset plane,
for focal drift
compensation.
ZDC
as offset.
Scanning
unit
Maintain Cell Activity Over A Long Period
Proprietary CO2 incubator control keeps the environment inside the tissue culture dish completely stable. The environment is precisely
maintained at 37°C with 90% humidity and 5% CO2 concentration.
0 s
1000 s
2000 s
3000 s
4000 s
5000 s
6000 s
7000 s
Human lymphoblast cells TK6
Courtesy of: Masamitsu Honma, Dir.
Biological Safety Research Center Div. of Genetics and Mutagenesis I, National Institute of Health Sciences
Download from Www.Somanuals.com. All Manuals Search And Download.
19
Application/ Molecular Interaction Analysis
3D Mosaic Imaging
Mosaic imaging is performed using a high-magnification objective to acquire continuous 3D (XYZ) images
of adjacent fields of view using the motorized stage, utilizing proprietary software to assemble the
images. The entire process from image acquisition to tiling can be fully automated.
Mosaic Imaging for 3D XYZ Construction
Composite images are quickly and easily prepared using the stitching function, to form an image over a wide area. 3D construction can
also be performed by acquiring images in the X, Y and Z directions. Tiled images can be enlarged in sections without losing resolution.
CNS markers in normal mice
Objective
Zoom
: PLAPON60x
: 2x
Image acquisition numbers (XY): 32 x 38, 48 slices for each image
Courtesy of: Dr. Mark Ellisman PhD, Hiroyuki Hakozaki, MS Mark Ellisman
National Center for Microscopy and Imaging Research (NCMIR),
University of California, San Diego
Automated from 3D Image Acquisition to Mosaic Imaging
Multi-area time-lapse software automates the process
from 3D image acquisition (using the motorized XY
stage) to stitching. The software can be used to easily
register wide areas, and the thumbnail display
provides a view of the entire image acquired during
the mosaic imaging process.
Coordinate Information
Thumbnail
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Expandability to Support Diverse Application.
Application
Standard Functions
Optional Functions
Intracellular diffusion measurement
Calculation of diffusion coefficients for intracellular molecules, and analysis of
molecular binding and changes in molecular density.
Supports a wide range of methods (RICS/ccRICS, point FCS/point FCCS and
FRAP).
Molecular interaction and
molecular concentration
analysis
—
1.5
1
130
0.5
Software Required: Diffusion measurement package
125 Pixels
0
105
125
105
130
Pixels
Laser Light stimulation
Acquires images while rapidly switching SIM scanner system
the built-in laser between imaging and Performs simultaneous imaging and laser light stimulation. Provides detailed
laser light stimulation.
settings for laser light stimulation including position and timing.
Features tornado scanning for high-efficiency bleaching using laser light
stimulation.
Features tornado scanning for high-
efficiency bleaching using laser light
stimulation.
Equipment Required: SIM scanner, laser combiner (dual fiber version)
Multi-point laser light stimulation system
Register multiple points for laser light stimulation, and program the respective
stimulation order, stimulation time and type of stimulation (continuous laser light
or pulse laser light).
Software Required: Multi-stimulation software
Multi-dimensional
Long time-lapse system
time-lapse imaging
Microscopes equipped with zero drift compensation (ZDC) acquire each image at
a set focus plane. The microscope CO2 incubator maintains cell activity for a long
period for continuous imaging.
P2
P3
P1
—
Equipment Required: IX81-ZDC microscope, CO2 incubator
P4
P5
Multi-point scanning system
Register multiple points for repeated image acquisition. Efficiently observe multiple
cells in parallel on 35-mm dishes, microplates or chamber slides.
Software and Equipment Required:
Multi-area time-lapse software, motorized XY stage**
3D mosaic imaging
3D mosaic imaging system
Continuous imaging of adjacent fields of view and mosaic imaging to form a
composite image.
—
Acquisition of adjacent Z-series images for 3D mosaic imaging.
Software and Equipment Required:
Multipoint time-lapse software, motorized XY stage**
TIRFM
TIRFM imaging
Uses the laser from the laser combiner to provide evanescent illumination, for
imaging the movement of molecules near the glass surface, such as cell
membranes and adhesion factors.
—
Software and Equipment Required: TIRFM unit*, TIRF objective, high-
sensitivity CCD camera**, CCD camera control software**
FRET
Provides FRET analysis functions.
Diode laser offers exceptional stability Ratio imaging and sensitized emission.
CFP-YFP FRET
and long life.
Available 440 nm diode laser is optimized for CFP-YFP FRET experiments
methods.
Diode laser offers exceptional stability and long life.
Equipment Required: LD 440 nm Laser
Supports FRET efficiency
measurements using acceptor
photobleach method.
Multi-color imaging
Three-channel detector for
simultaneous acquisition of
fluorescence images from three
different dyes.
Imaging blue dyes
Available 405-nm laser for image acquisition of multi-stained samples labeled with
V-excitation fluorescent dyes such as DAPI, Hoechst and Alexa 405.
Equipment Required: LD 405 nm laser
Sequential mode for acquisition of
fluorescence images without cross-talk.
Fluorescence can also be separated
using unmixing (only available on
spectral scan unit).
Simultaneous four-color imaging
Fourth channel detector can be easily added to simultaneously acquire images of
four colors.
Equipment Required: 4-channel detector
Colocalization analysis
Easily determine if labeled substances High-accuracy colocalization analysis
are present locally in the same
locations.
New 60x oil-immersion objective offers image acquisition with exceptional
positional accuracy coefficient.
Calculate of Pearson coefficients,
overlap coefficients and colocalization
indices.
Equipment Required: PLAPON 60xOSC
* SIM scanner and TIRFM scanner cannot be installed on the same system.
** For more information about peripheral equipment, contact your Olympus dealer.
Download from Www.Somanuals.com. All Manuals Search And Download.
21
Expandability
HeNe
Argon
Argon
n
e
ulti
ulti
re
M
9
LD
35 LD
6
440 LD458
M
473 LD
515
543
G
55
488 Argon
405 LD
300
350
400
450
500
550
600
650
700
750
800
mCherry
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Scanning Units
Two types of scanning units, filter-based
and spectral detection, are provided. The
design is all-in-one, integrating the
scanning unit, tube lens and pupil
projection lens. Use of the microscope
fluorescence illuminator light path ensures
that expandability of the microscope itself
is not limited. Visible, UV and IR laser
introduction ports are provided, as well as
a feedback control system.
Scanning Unit for IX81 Inverted Microscope
Scanning Unit for BX61/BX61WI Upright Microscopes
Dedicated mirror unit cassette is required.
Fluorescence illuminator integrated with scanning unit.
Laser Systems
The multi-combiner enables combinations
with all of the following diode lasers: 405
nm, 440 nm, 473 nm, 559 nm and 635 nm.
The system can also be equipped with
conventional Multi-line Ar laser and
HeNe(G) laser.
Dual Type
Single Type
The multi-combiner outputs laser light with two fibers.
Light can be used both for observation and laser light
stimulation.
Single channel laser output. AOTF is standard
equipment.
Illumination Units
Conventional illumination modules are
designed for long-duration time-lapse
experiments. Since light is introduced
through fiber delivery systems, no heat is
transferred to the microscope.
Fluorescence Illumination Unit
Transmitted Light Detection Unit
Stand with Mercury lamp house, motorized shutter,
and fiber delivery system for conventional fluorescence
observation. Light introduction via fiber optic port.
External transmitted light photomultiplier detector and
100 W Halogen conventional illumination, integrated
for both laser scanning and conventional transmitted
light Nomarski DIC observation. Motorized exchange
between transmitted light illumination and laser
detection. Simultaneous multi-channel confocal
fluorescence image and transmitted DIC acquisition
enabled.
Optional Upgrade Equipments for FV1000
4th Channel Detector Unit
SIM Scanner
TIRFM Unit
Fiber Port for Fluorescence Output
Attaches to the optional port of either
the filter or spectral type scanning unit
and is used as a 4th confocal fluo-
rescence detection channel. This is a
filter-based fluorescence detection unit.
Second scanner dedicated for laser light
stimulation, synchronized to the FV1000
main scanner for simultaneous laser
light stimulation and confocal image
acquisition. Independent fiber optic laser
introduction port. Dichromatic mirror
within motorized optical port of the scan
unit required for introduction of laser
into main scanner.
Enables control of the necessary volume
Confocal fluorescence emission can be
introduced via fiber delivery system into
external device. Fiber port equipped
with FC connector (fiber delivery system
not included).
of excitation light using FV1000 soft-
ware. This unit enables TIRF imaging
using the laser light source used with
Confocal.
Download from Www.Somanuals.com. All Manuals Search And Download.
23
Expandability
FV1000 System Diagram
Fluorescence illumination unit
CO2 incubator *
E
Scanning unit for IX81
(Spectral type or Filter type
detector system )
Motorized XY stage *
F
G
A
LD635 laser
AOTF Laser combiner
(Single-fiber type)
635 nm
LD559 laser
559 nm
B
D
B
A
IX81
HeNeG laser
543 nm
Select either laser
IX81-ZDC
Cover *
Inverted motorized microscope
Multi Ar laser
458, 488, 515 nm
AOTF Laser combiner
(Dual-fiber type)
LD473 laser
473 nm
Select either laser
B
C
TIRFM unit *
Scanning unit for BX61WI, BX61
(Spectral type or Filter type detector system)
G
LD440 laser*
440 nm
G
F
SIM Scanner*
LD405 laser*
405 nm
D
IR laser*
D
B
A
C
Transmitted light detection unit
E
E
F
BX61WI
BX61
Upright motorized microscope
Fiber port for
fluorescence
output*
FV Power supply *
Microscope
control unit
4th channel
detector unit*
Software
Basic software
Review station software *
Diffusion Measurement Package *
Multi Stimulation Software *
FV control unit
Monitor
FV power
supply unit
Multi Area Time Lapse Software *
*Optional unit
IX81-ZDC
Focal drift compensation for long time-
lapse imaging.
* Requires IX81 microscope. For information about ZDC-
compatible objectives, contact your Olympus dealer.
CO2 Incubator/
High-Precision Motorized Stage/
MIU-IBC-IF-2, MIU-IBC-I-2
PRIOR H117
Highly precise incubator control keeps
the environment inside a laboratory dish
completely stable, at just below 37°C
temperature, 90% moisture and 5%
CO2 concentration; in this way, live cell
activity can be maintained for
Multi-point time-lapse photography
using a 35 mm glass-bottom dish is
easy to perform with this motorized
stage, which can reproduce previously-
set positions with extreme precision. It
also allows efficient photographing of
multiple cells and detection of individual
cells showing expected reactions.
approximately two days.
* Not available in some areas
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Main Specifications
Spectral Version
Filter Version
Laser Light
Ultraviolet/Visible Light Laser LD lasers: 405 nm: 50 mW, 440 nm: 25 mW, 473 nm: 15 mW, 559 nm: 15 mW, 635 nm, 20 mW
Multi-line Ar laser (458 nm, 488 nm, 515 nm, Total 30 mW), HeNe(G) laser (543 nm, 1 mW)
AOTF Laser Combiner
Visible light laser platform with implemented AOTF system, Ultra-fast intensity modulation with individual laser lines, additional shutter control
Continuously variable (0.1%–100%, 0.1% increment), REX: Capable of laser intensity adjustment and laser wavelength selection for each region
Fiber
Broadband type (400 nm–650 nm)
Scanning and
Detection
Scanner Module
Standard 3 laser ports, VIS – UV – IR
Excitation dichromatic mirror turret, 6 position (High performance DMs and 20/80 half mirror), Dual galvanometer mirror scanner (X, Y)
Motorized optical port for fluorescence illumination and optional module adaptation, Adaptation to microscope fluorescence condenser
Detector Module
Standard 3 confocal Channels (3 photomultiplier detectors)
Additional optional output port light path available for optional units
6 position beamsplitter turrets with CH1 and CH2
CH1 and CH2 equipped with independent grating and slit for fast and
flexible spectral detection
Standard 3 confocal Channels (3 photomultiplier detectors)
Additional optional output port light path available for optional units
6 position beamsplitter turrets with CH1 and CH2
CH1 to CH3 each with 6 position barrier filter turret
(High performance filters)
Selectable wavelength bandwidth: 1–100 nm
Wavelength resolution: 2 nm
Wavelength switching speed: 100 nm/msec
CH3 with 6 position barrier filter turret
Filters
Scanning Method
Scanning Modes
High performance sputtered filters, dichromatic mirrors and barrier filters
2 galvanometer scanning mirrors
Scanning speed: 512 x 512 (1.1 sec., 1.6 sec., 2.7 sec., 3.3 sec., 3.9 sec., 5.9 sec., 11.3 sec., 27.4 sec., 54.0 sec.)
256 x 256 bidirectional scanning (0.064 sec., 0.129 sec.)
X,Y,T,Z,λ
X,Y,T,Z
Line scanning: Straight line with free orientation, free line, Point scanning
Line scanning: Straight line with free orientation, free line, Point scanning
Photo Detection Method
Pinhole
2 detection modes: Analog integration and hybrid photon counting
Single motorized pinhole
pinhole diameter ø50–300 µm (1 µm step)
Single motorized pinhole
pinhole diameter ø50–800 µm (1 µm step)
Field Number (NA)
Optical Zoom
Z-drive
18
1x–50x in 0.1x increment
Integrated motorized focus module of the microscope, minimum increment 0.01 µm or 10 nm
Transmitted Light
Detector unit
Module with integrated external transmitted light photomultiplier detector and 100 W Halogen lamp, motorized switching, fiber adaptation to microscope
frame
Microscope
Motorized Microscope
Inverted IX81, Upright BX61, Upright focusing nosepiece & fixed stage BX61WI
Fluorescence Illumination
Unit
External fluorescence light source with motorized shutter, fiber adaptation to optical port of scan unit
Motorized switching between LSM light path and fluorescence illumination
System Control PC
PC-AT compatible, OS: Windows XP Professional (English version), Windows Vista (English version), Memory: 2.0 GB or larger, CPU:Core2Duo 3.0 GHz,
Hard disk: 500 GB or larger, Media: DVD Super Multi Drive, FV1000 Special I/F board (built-in PC), Graphic board: conformity with Open GL
Power Supply Unit
Galvo control boards, scanning mirrors and gratings, Real time controller
Galvo control boards, scanning mirrors
Display
SXGA 1280X1024, dual 19 inch (or larger) monitors or WQUXGA 2560 x 1600, 29.8 inch monitor
Optional Unit
SIM Scanner
2 galvanometer scanning mirrors, pupil projection lens, built-in laser shutter, 1 laser port, Fiber introduction of near UV diode laser or visible light laser,
Optional: 2nd AOTF laser combiner
TIRFM Unit
4th CH Detector
Fiber Port for Fluorescence
Available laser: 405–633 nm. Motorized penetration ratio adjustment. Automatic optical setting for TIRFM objectives
Module with photomultiplier detector, barrier filter turret, beamsplitter turret mounted with 3rd CH light path
Output port equipped with FC fiber connector (compatible fiber core 100–125 µm)
Software
Image Acquisition
Normal scan: 64 x 64, 128 x 128, 256 x 256, 320 x 320, 512 x 512, 640 x 640, 800 x 800, 1024 x 1024, 1600 x 1600, 2048 x 2048, 4096 x 4096
Clip rectangle scan ,Clip ellipse scan ,Polygon clip scan,line scan ,free line scan,Point scan, Real-time image
2-dimension: XY, XZ, XT and Xλ
3-dimension: XYZ, XYT, XYλ, XZT, XTλ and XZλ
4-dimension: XYZT, XZTλ and XYTλ
5−dimension: XYZTλ
Programmable Scan Controller
2D Image Display
Time Controller function
Each image display: Single-channel side-by-side, merge, cropping, live tiling, live tile, series (Z/T/λ),
LUT: individual color setting, pseudo-color, comment: graphic and text input
3D Visualization and Observation
Interactive volume rendering: volume rendering display, projection display, animation displayed (save as OIF, AVI or MOV format)
Free orientation of cross section display
3D animation (maximum intensity projection method, SUM method)
3D and 2D sequential operation function
Image Format
OIB/ OIF image format
8/ 16 bit gray scale/index color, 24/ 32/ 48 bit color,
JPEG/ BMP/ TIFF/ AVI/ MOV image functions
Olympus multi-tif format
Spectral Unmixing
Image Processing
2 Fluorescence spectral unmixing modes (normal and blind mode)
Filter type: Sharpen, Average, DIC Sobel, Median, Shading, Laplacian
Calculations: inter-image, mathematical and logical, DIC background leveling
Image Analysis
Statistical Processing
Optional Software
Fluorescence intensity, area and perimeter measurement, time-lapse measurement
2D data histogram display, colocalization
Review station software, Off-line FLUOVIEW software for date analysis.
Motorized stage control software, Diffusion measurement package, Multi stimulation software, Multi area time-lapse software
Objectives for BX2 and IX2
(using U-UCD8A-2, IX2-LWUCDA2 and U-DICTS)
Objectives for fixed stage upright microscope
(using WI-UCD, WI-DICTHRA2)
Objectives
NA
W.D. (mm)
DIC prism
Revolving
nosepiece
Cover glass
W.D.
(mm)
Condenser for BX2
U-UCD8A-2
optical element
Condenser for IX2
IX2-LWUCDA2
optical element
Correction
ring
U-DICTS
position
Description
NA
thickness
(mm)
Immersion
WI-SSNP,
WI-SRE3
MPLN5X
0.10
0.30
20.00
3.50
–
UPLSAPO4X
0.16
0.40
0.75
0.85
0.95
1.35
1.20
1.40
1.42
1.40
1.30
1.49
1.49
1.45
1.65
13
—
0.17
WI-SSNP,
WI-SRE3
UMPLFLN10XW
UMPLFLN20XW
LUMPLFLN40XW
LUMPLFLN60XW
WI-DIC10HR
UPLSAPO10X2
UPLSAPO20X
3.1
U-DIC10
U-DIC20
U-DIC20
U-DIC40
U-DIC60
U-DIC60
U-DIC100
U-DIC60
U-DIC60
U-DIC40
U-DIC60
U-DIC100
U-DIC100
U-DIC100
IX2-DIC10
IX2-DIC20
IX2-DIC20
IX2-DIC40
IX2-DIC60
IX2-DIC60
IX2-DIC100
IX2-DIC60
IX2-DIC60
IX2-DIC40
IX2-DIC60
IX2-DIC100
IX2-DIC100
IX2-DIC100
normal
normal
normal
normal
BFP1
WI-SSNP,
WI-SRE3
0.6
0.17
0.50
0.80
1.00
3.50
3.30
2.00
WI-DIC20HR
WI-DIC40HR
WI-DIC60HR
WI-DIC60HR
UPLSAPO20XO
UPLSAPO40X2
UPLSAPO60XO
UPLSAPO60XW
UPLSAPO100XO
PLAPON60XO
PLAPON60XOSC
UPLFLN40XO
0.17
0.18
0.15
0.28
0.12
0.15
0.12
0.2
—
Oil
WI-SSNP,
WI-SRE3
0.11-0.23
0.17
_
_
Oil
Water
Oil
WI-SSNP,
WI-SRE3
0.13-0.21
0.17
normal
normal
BFP1
WI-SSNP,
WI-SRE3
LUMFLN60XW
1.10
1.5
2.0
0.17
Oil
XLUMPLFLN20XW
1.00 *
WI-DICXLU20HR WI-SNPXLU2
0.17
Oil
BFP1
0.17
Oil
BFP1
* Note: These conditions are not met in confocal microscopy
APON60XOTIRF
UAPON100XOTIRF
UAPON150XOTIRF
Apo100XOHR
0.1
0.13-0.19
0.13-0.19
0.13-0.19
0.15
Oil
_
_
_
BFP1
0.1
Oil
normal
normal
normal
0.08
0.1
Oil
Oil
Download from Www.Somanuals.com. All Manuals Search And Download.
25
Expandability
Dimensions, Weight and Power Consumption
Dimensions (mm)
Weight (kg)
Power consumption
Microscope with scan unit
BX61/BX61WI
IX81
320 (W) x 580 (D) x 565 (H)
350 (W) x 750 (D) x 640 (H)
41
51
—
Fluorescence illumination unit
Lamp
Power supply
180 (W) x 320 (D) x 235 (H)
90 (W) x 270 (D) x 180 (H)
6.7
3.0
AC 100-240 V 50/60 Hz 1.6 A
—
Transmitted light detection unit
Microscope control unit
FV Power supply unit
170 (W) x 330 (D) x 130 (H)
125 (W) x 332 (D) x 216 (H)
180 (W) x 328 (D) x 424 (H)
180 (W) x 420 (D) x 360 (H)
363 (W) x 216 (D) x 389.5–489.5 (H)
689 (W) x 254.7 (D) x 511.5–629.5(H)
210 (W) x 300(D) x 100 (H)
514 (W) x 504 (D) x 236 (H)
514 (W) x 364 (D) x 236 (H)
200 (W) x 330 (D) x 52 (H)
162 (W) x 287 (D) x 91 (H)
130 (W) x 224 (D) x 62 (H)
5.9
5.2
7.5
10.5
5.9
15.7
4.0
45
AC 100-120/220-240 V 50/60 Hz 3.5 A/1.5 A
AC 100-120/220-240 V 50/60 Hz 4.0 A/2.0 A
AC 100/240 V 50/60 Hz 497.5 W
AC100-120/200-240 V 50/60 Hz 0.65 A/0.4 A
AC100-120/200-240 V 50/60Hz 1.8 A/0.8 A
AC 100-120/200-240 V 50/60 Hz 2.0 A/1.0 A
—
FV control unit (PC)
19 inch, dual (value per monitor)
29.8 inch
Display
Power supply unit for laser combiner
Laser combiner (with Ar laser heads)
Laser combiner (without Ar laser heads)
LD559 laser power supply
40
—
1.2
4.4
1.8
AC 100-240 V 50/60 Hz 30 W
AC 100-240 V 50/60 Hz 20 A
AC 100-120 V 50/60 Hz 0.45 A
Multi Ar laser power supply
HeNe(G) laser power supply
Recommended FV1000 system setup
(IX81, BX61, BX61WI)
(unit: mm)
*1 This product corresponds to regulated goods as stipulated in the "Foreign Exchange and Foreign Trade Control Law".
An export license from the Japanese government is required when exporting or leaving Japan with this product.
*2 The performance and safety of this device is not guaranteed if it is disassembled or modified.
*3 This device is designed for use in industrial environments for the EMC performance. (IEC61326-1 Class A device)
Using it in a residential environment may affect other equipment in the environment.
680
1200
1880
Depth: 990
Images are courtesy of the following institutions:
"Brainbow" mouse brain stem
Mouse brain section
Osteoclast induced from rat monocyte in rat kidney
Courtesy of Dr. Keiko Suzuki,
Department of Pharmacology, Showa University School of
Dentistry
Courtesy of the laboratories of Jeff W. Lichtman and Joshua R.
Sanes Harvard University MCB Department and the Center for
Brain Science
Courtesy of Mr. Masayuki Sekiguchi (Section Chief)
Department of Degenerative Neurological Diseases,
National Institute of Neuroscience, National Center of
Neurology and Psychiatry
Hippocampal neurons
Courtesy of Dr. Shigeo Okabe
Department of Cellular Neurobiology, Graduate School of
Medicine, The University of Tokyo
Rudimentary limbs of larva in latter part of 3rd instar
Courtesy of Dr. Tetsuya Kojima
Laboratory of Innovational Biology, Department of Integrated
Biosciences, Graduate School of Frontier Sciences, University
of Tokyo
Fucci–Sliced mouse brain, expressing S/G2/M phases
Courtesy of Dr. Hiroshi Kurokawa, Ms. Asako Sakaue-Sawano
and Dr. Atsushi Miyawaki
RIKEN Brain Science Institute Laboratory for Cell Function
Dynamics
Cultured nerve cells derived from the mouse hippocampus
Courtesy of Dr. Koji Ikegami, Dr. Mitsutoshi Setou
Molecular Geriatric Medicine, Mitsubishi Kagaku Institute of Life
Sciences
Zebrafish
Courtesy of Dr. Toru Murakami,
Department of Neuromuscular & Developmental Anatomy,
Gunma University Graduate School of Medicine
Immunolabeling of a transgenic mouse retina showing the
major retinal cells types
Courtesy of Dr. Rachel Wong, Mr. Josh Morgan
Dept. Biological Structure, University of Washington, Seattle.
Cerebellum Purkinje cell
Courtesy of Dr. Tetsuro Kashiwabara, Assistant Professor; and
Dr. Akira Mizoguchi, Professor;
Neuroregenerative medicine course, Mie University School of
Medicine
Medaka embryogenesis (somite stage)
Courtesy of Minoru Tanaka, Hiromi Kurokawa
National Institute for Basic Biology Laboratory of Molecular
Genetics for Reproduction
Wild-type embryo in stage 17 of drosophila
Courtesy of Dr. Tetsuya Kojima
Laboratory of Innovational Biology, Department of Integrated
Biosciences
Graduate School of Frontier Sciences, University of Tokyo
Drosophila, Stage 14
Courtesy of Dr. Tetsuya Kojima
Laboratory of Innovational Biology, Department of Integrated
Biosciences Graduate School of Frontier Sciences, University
of Tokyo
Pilidium larva of Micrura alaskensis
Alpha Blend method (Cultured nerve cells derived from the
mouse hippocampus)
Courtesy of Dr. Koji Ikegami, Dr. Mitsutoshi Setou
Molecular Geriatric Medicine, Mitsubishi Kagaku Institute of Life
Sciences
Courtesy of Dr. Svetlana Maslakova of the University of
Washington and Dr. Mikhail V Matz of the Whitney Laboratory
for Marine Bioscience, University of Florida.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
FLUOVIEW website
• OLYMPUS CORPOARATION is ISO9001/ISO14001 certified.
• Illumination devices for microscope have suggested lifetimes.
Periodic inspections are required. Please visit our web site for details.
• Windows is a registered trademark of Microsoft Corporation in the United States and other
countries. All other company and product names are registered trademarks and/or trademarks of
their respective owners.