PT-E06
取扱説明書
デジタルカメラ
用防水プロテクター
Instruction Manual
En
Underwater Case for digital camera
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
1 Keep this product out of the reach of babies, infants, and children. There is the possibility of
occurrence of the following types of accidents.
• Injury by dropping onto the body from heights.
• Injury from parts of the body getting caught in parts which open and close.
• Swallowing of small parts, O-ring, silicone grease and silica gel. Please consult a physician
immediately if any parts have been swallowed.
2 Do not store digital camera with batteries inserted in this product.
Storage with a battery inserted may lead to leakage of the battery liquid and fire hazard.
3 The Case must be used in combination with the Waterproof Port available separately. Remember
that the Case cannot be used without the Waterproof Port.
4 If leakage of water should occur with a camera installed in this product, quickly remove the battery
from the camera. There is the possibility of ignition and explosion from generation of hydrogen gas.
5 This product is made of resin. There is the possibility that injuries may be caused when it becomes
broken due to strong impact with a rock or other hard objects. Please handle it with sufficient care.
CAUTION
1 Do not disassemble or modify this product. This may cause water leakage or defect. In case of the
loss of image data caused by disassembly, repair or modification etc. by any party other than those
appointed by OLYMPUS IMAGING CORP., we shall bear no responsibility for damage.
2 Use or storage of the product at the following locations may cause defective operation, defects,
damage, fire, internal fogging, or water leakage. This should be avoided.
• Locations reaching high temperatures such as those under direct sunlight, in an automobile, etc.
• Locations close to fire
• A water depth in excess of 40 m
• Locations subject to vibrations
• Locations with high temperature and humidity or with extreme temperature changes
• Locations with volatile substances
3 Opening and closing at locations with much sand, dust, or dirt may impair the waterproof
characteristic and cause water leakage. This should be avoided.
4 This product is not a case to soften impacts to the camera inside the product. When this product with
a digital camera inside is subjected to impacts or heavy objects are placed onto it, the digital camera
may be damaged. Please handle it with sufficient care.
5 Do not use the following chemicals for cleaning, corrosion prevention, prevention of fogging, repair
or other purposes. When these are used for the Case directly or indirectly (with the chemicals in
vaporized state), they may cause cracking under high pressure or other problems.
En
Chemicals which cannot be
Explanation
used
Do not clean the Case with alcohol, gasoline, thinner or other volatile
Volatile organic solvents,
organic solvents or with chemical detergents etc. Pure water or
chemical detergents
lukewarm water is sufficient for cleaning.
Do not use anticorrosion agents. Pure water is sufficient when washing
Anticorrosion agent
the metal parts as stainless steel and brass are used.
Commercial defogging
agents
Do not use commercial defogging agents. Always use the specified
desiccant silica gel.
Use only the specified silicone grease for the silicon O-ring, as
otherwise the O-ring surface may deteriorate and water leakage may
occur.
Grease other than specified
silicone grease
Do not use adhesive for repairs or other purposes. When repair is
required, please contact a dealer or a service station of OLYMPUS
IMAGING CORP.
Adhesive
EN 2
Download from Www.Somanuals.com. All Manuals Search And Download.
6 Jumping into the water with the Case in your pocket or in your hand, throwing the Case from a boat
or ship into the water, and other rough handling may cause water leakage. Please handle with
sufficient care, when handing it over from hand to hand etc.
7 If the camera on the inside should become wet because of water leakage etc., immediately wipe off
all moisture and confirm the operation.
8 Be careful not to apply excessive force to the port connector, TTL cable connector, zoom dial or tripod
seat.
9 Do not push the air vent valve from inside.
0 Please remove the O-ring when traveling by air. Otherwise air pressure may make it impossible to
open the Case.
a For safe use of the digital camera in this product, please read the “Instruction Manual” for the digital
camera carefully.
b When sealing this product, take sufficient care that no foreign matter gets caught at the O-ring and
the contact surfaces.
c The camera’s built-in flash cannot be used when the Case is combined with an external Olympus
flash. Also, the camera’s built-in flash cannot be popped up if the hot shoe cable is connected to the
camera’s hot shoe. If the built-in flash is forcibly popped up, the connected flash will not work properly
and the hot shoe cable may be disconnected from the camera’s hot shoe. In this case, the camera
may also be damaged.
d The camera’s built-in flash cannot be used when the camera is in the Case.
En
EN 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Introduction ............................................................................................................................ 1
Please read the following items before use ........................................................................... 1
For safe use ........................................................................................................................... 1
1.Preparations.............................................................................................................6
Check the contents of the package........................................................................................ 6
Names of the parts........................................................................................................... 7
Install the Waterproof Port ..................................................................................................... 8
Attach the hand strap ............................................................................................................. 8
How to attach and detach the camera table........................................................................... 9
2.Advance check of the Case..................................................................................10
Advance check before use................................................................................................... 10
3.How to connect the electronic flash....................................................................11
Connecting the underwater optical fiber cable ..................................................................... 11
When using the TTL cable ................................................................................................... 12
4.Installing the digital camera .................................................................................14
Check the digital camera...................................................................................................... 14
Open the Case ..................................................................................................................... 15
Attach the digital camera to the camera table...................................................................... 15
Insert the digital camera in the Case.................................................................................... 16
Check the loading status...................................................................................................... 17
Seal the Case....................................................................................................................... 18
Check the operation of the loaded camera .......................................................................... 18
Perform the final checks....................................................................................................... 18
Visual Inspection............................................................................................................ 18
Water Leakage Test............................................................................................................. 19
En
5.Handling After Shooting .......................................................................................20
Wipe off any waterdrop ........................................................................................................ 20
Unload the digital camera .................................................................................................... 20
Wash the Case with pure water ........................................................................................... 20
Dry the Case ........................................................................................................................ 21
6.Maintaining the Waterproof Function..................................................................22
Remove the O-ring............................................................................................................... 22
Remove any sand, dirt, etc. ................................................................................................. 22
Install the O-ring................................................................................................................... 22
How to Apply Grease to the O-ring ...................................................................................... 23
Replace consumable products............................................................................................. 24
Maintenance of the threaded sections on the TTL cable and TTL cable connector............. 24
Maintenance of the TTL Connector Cap .............................................................................. 24
EN 4
Download from Www.Somanuals.com. All Manuals Search And Download.
7.Appendix ................................................................................................................25
Specifications ....................................................................................................................... 25
Supplied accessories for PT-E06................................................................................... 25
Waterproof Port.............................................................................................................. 26
Optional accessories...................................................................................................... 26
En
EN 5
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Preparations
Check the contents of the package
Check that all accessories are in the box.
Contact your dealer if accessories are missing or damaged.
•
Hand strap
•
Silica gel (2g)
•
Case body
(Check that the O-ring is installed on
both of rear case and front case.)
•
Silicone grease
•
O-ring remover
•
Maintenance adapter
•
•
Authorized distributors list/Authorized
service centres list
Instruction manual (this manual)
En
CAUTION:
After purchase, be sure to do maintenance even in brand-new condition. Neglecting the maintenance may
become the cause of water leakage.
For how to maintenance the case, refer to P.22.
EN 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Names of the parts
1 Palm grip
*e MENU button
*u
(Erase) button
*2 Shutter lever
3 Hand strap ring
*4 F (Exposure correction)
button
*5 Mode dial knob
6 Accessory mount
7 TTL cable connector
8 Optical fiber cable insertion
slot, cap
*f INFO (Info display) button
g Air vent valve
v LCD monitor window
w LCD hood
x Rear lid
y LCD hood strap
z Hot shoe cable connectors
(w/caps)
A Loading guide rails
B O-ring (POL-E06B)
C Tripod seat
h Pickup finder
*i AEL/AFL button
*j Control dial knob
*k Fn button
*l P (AF target) button
*m q (Play) button
*n u button
*9 Zoom dial
0 Body cap
*a Power switch lever
b Front lid
c Slide lock
D O-ring (POL-E06A)
E LCD inner hood
F Camera table lock
G Camera table
H Eyecup storage space
I Hot shoe cover storage
space
*o i button
*p Cross-cursor button S
*q Cross-cursor button X
*r Cross-cursor button T
*s IS button
En
d Open/close dial
*t Cross-cursor button W
Note:
Case operation parts marked by * corresponds to the operation parts of the digital camera. When the
operation parts of the Case are operated, the corresponding functions of the digital camera will operate. For
details of the functions, refer to the instruction manual for the digital camera.
EN 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the Waterproof Port
To enable the Case to be used underwater, the separately available Waterproof Port for the camera lens
must be installed on the Case. Align the Waterproof Port with the position where the camera lens will be
when the camera is loaded in the Case.
• Refer to the instruction manual provided with the Waterproof Port before attaching the Waterproof Port
to the Case.
• Apply the provided Silicon grease to the O-ring section of the Waterproof Port and the Waterproof Port
mounting thread on the Case.
• Screw the Waterproof Port into the Case by turning it clockwise all the way.
Waterproof Port mount thread
Silicon grease
CAUTION:
The Case should not be used underwater at depths that exceed 40 meters. Even when the attached
underwater lens port or other equipment is able to withstand depths exceeding 40 meters, the Case itself
cannot be used at depths of more than 40 meters.
Attach the hand strap
Attach the hand strap to the Case.
En
Hand strap ring
Hand strap
EN 8
Download from Www.Somanuals.com. All Manuals Search And Download.
How to attach and detach the camera table
The camera table inside the front lid of the Case is used to load the digital camera into the Case.
How to detach the camera table
1 Slide and hold the Case’s slide lock and open the open/
close dial, then open the rear lid.
2 Slide the camera table lock to the left to unlock the
camera table.
Slide the table towards the rear.
How to attach the camera table
1 Slide the camera table all the way into the camera table
loading grooves on the front-lid side of the Case.
Slide the camera table lock to the right to lock the camera
table.
2 Gently close the rear lid of the Case and close the open/
close dial firmly.
CAUTION:
Closing the rear lid of the Case before the camera table is inserted all the way (until it stops), into the camera
table loading grooves could damage the Case and the camera.
En
EN 9
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Advance check of the Case
Advance check before use
This Case has been the subject of thorough quality control for the parts during the manufacturing
process and thorough function inspections during the assembly. In addition, a water pressure test is
performed with a water pressure tester for all products to confirm that the performance conforms to the
specifications.
However, depending on the carrying and storage conditions, the maintenance status, etc., the
waterproof function may be damaged.
Before using, always perform the following advance checks.
Check the waterproof parts of the Case
Check the waterproof parts of the Case as described below.
1 Ensure that the Case’s O-rings are firmly attached and secured with the slide lock and the open/close
dial.
2 Ensure that the separately available Waterproof Port is installed correctly, and that the Waterproof
Port is attached firmly to the O-ring between the Waterproof Port and Case.
3 Ensure that the O-ring of the TTL connector is attached firmly and that the cap is screwed into the
connector without loosening.
Advance check
1 Before loading the digital camera in the Case, immerse the empty Case to confirm that there is no
water leakage. When it is difficult, water leakage can be checked by referring “Water Leakage Test”
(P.19).
2 Main causes of water leakage are as follows.
• Forgetting to install the O-ring
• Part of an O-ring or an entire O-ring is outside the specified groove.
• O-ring damage, cracks, deterioration or deformation
• Sand, fibers, hair or other foreign matter sticking to the O-ring, the O-ring groove or the O-ring
contact surface.
• Damage to an O-ring groove or O-ring contact surface.
• Attached strap or silica gel getting caught when closing the Case.
Perform the test after the above causes have been eliminated.
En
CAUTION:
If the advance test should show water leakage with normal handling, stop using the Case and contact your
dealer or an Olympus service station.
EN 10
Download from Www.Somanuals.com. All Manuals Search And Download.
3. How to connect the electronic flash
Connecting the underwater optical fiber cable
To connect the UFL-2 underwater flash (optional) to the Case using an underwater optical fiber cable
(optional), follow the procedures below.
How to connect the underwater optical fiber
cable
1 Remove the cap of the optical fiber cable
insertion slot.
2 Put the underwater optical fiber cable plug all the
way into the optical fiber cable insertion slot.
Setting of the digital camera
1 Set the RC mode of the camera to ON so that the camera's built-in flash is activated.
2 Load the camera in the Case with the camera's built-in flash popped up.
Refer to the UFL-2 instruction manual for the UFL-2 operation.
CAUTION:
When using a non-Olympus manufacturer's slave-type flash with underwater optical fiber cable, set the
camera's built-in flash to manual.
En
If the camera's built-in flash ratio is more than 1/64, the camera's built-in flash light may reflect in the lens port
and be taken into the picture.
EN 11
Download from Www.Somanuals.com. All Manuals Search And Download.
When using the TTL cable
When connecting the optional electronic flash with the underwater TTL cable (optional: PTCB-E01),
connect the hot shoe cable (optional: PHCB-01) to the camera and front cover of the Case.
Connecting the underwater TTL cable
1 Turn the TTL connector cap of the Case counter-
clockwise and remove it.
2 Connect the underwater TTL cable (optional:
PTCB-E01) to the TTL connector on the Case.
Underwater
TTL cable
Use this mark to
align the position.
Insert into the
connector.
Turn the threaded
section of the
connector clockwise
gently until it stops.
3 When not using the underwater TTL cable,
attach the TTL connector cap.
Make sure there is no foreign matter attached to the
O-rings inside the cap and on the TTL cable
connector. After that, gently turn it clockwise until it
stops.
Check O-rings
Cap
Connector
CAUTION:
If the TTL connector cap is loose, water leakage may result.
En
How to connect the hot shoe cable
1 Turn the hot shoe cable connector cap inside the Case counter-clockwise to remove it.
2 Insert the connector of the hot shoe cable into the Case's connector and turn the connector screws
all the way clockwise to connect them firmly.
3 Load the camera in the Case, and then connect the hot shoe cable to the camera.
EN 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting of the digital camera
1 Set the automatic pop-up setting of the camera to OFF. The camera’s built-in flash is designed to pop
up automatically when shooting under low light or against the sun in any scene mode other than the
AUTO or underwater modes. For details on camera function setup, refer to the camera’s instruction
manual.
2 Switch the electronic flash ON before switching the camera ON.
When using the electronic flash, be sure to turn it ON before turning the camera on.
If the automatic pop-up setting of the camera is ON and the camera is set to the scene mode other
than the AUTO or underwater modes, turning the camera ON before turning the electronic flash on
would cause the camera’s built-in flash to pop up automatically. Always be sure to turn the electronic
flash ON before turning the camera ON.
CAUTION:
• If the camera’s built-in flash pops up while the hot shoe cable is connected to the camera, it will interfere
with the hot shoe cable, either disconnecting it or causing a connection failure.
• When using a slave-type underwater flash from a non-Olympus manufacturer, pop the camera’s built-in
flash up before loading it in the Case.
• Once the Case has been sealed, the built-in flash cannot be popped up or stored.
En
EN 13
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Installing the digital camera
Check the digital camera
Check the digital camera before loading it in the Case.
1. Battery Confirmation
Underwater shooting can reduce battery life because the picture has to be checked on the LCD monitor
before and after shooting. Make sure that you have sufficient remaining battery capacity before use.
2. Check the remaining number of pictures
Check that the image storage medium has enough room for the number of pictures you want to take.
3. Remove the strap and lens cap from the camera.
If the digital camera is loaded without removing the strap and lens cap, the Case cannot be sealed
properly and may leak.
4. Remove the eyecup from the digital
camera.
To improve the view of the pickup viewfinder,
remove the camera’s eyecup before loading it in the
Case.
The eyecup removed from the camera can be
stored in the camera table.
En
CAUTION:
In case the digital camera is loaded in the Case without removing the eyecup and the rear lid of the Case is
closed, the pickup viewfinder pops out.
Remove the eyecup, then push in the pickup viewfinder.
5. Remove the filter from the digital camera
The digital camera cannot be loaded in the Case while the filter is attached to the lens.
EN 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Open the Case
1 Slide and hold the slide lock towards the arrow direction (1) and turn the open/close dial counter
clockwise (2).
2 Turn the open/close dial to the position where it cannot be turned further.
3 Open the rear lid of the Case gently.
Slide lock
1
2
CAUTION:
Do not exert too much force while turning the open/close dial. Doing so may damage the dial.
Attach the digital camera to the camera table
In order to load the camera into the Case, attach the camera table (located on the front-lid side of the
Case) to the digital camera.
1 The eyecup and the hot shoe cover of the digital
camera can be stored in the camera table.
2 Attach the camera table to the tripod seat section on
the bottom of the digital camera. Use the camera’s
tripod screw hole for attaching.
En
Front
3 The camera table has fixed up-down and front-rear
orientations. To ensure that it is properly attached,
refer to the illustration on the right.
Up
Down
Rear
EN 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Insert the digital camera in the Case
1 Pull out the zoom dial and mode dial on the Case (pulling out the mode dial also pulls up the power
switch lever) so that they do not get in the way while loading the digital camera.
At this time, set the orientation of the power switch lever as shown below.
2 After attaching the camera table to the digital camera, slide the camera table into the Case’s camera
table-loading groove. Do not insert the camera table by force. Slide it in gently while checking that
the digital camera does not interfere with the internal parts of the Case.
En
3 Gently push the Case’s zoom dial and mode dial down and confirm that the zoom dial can smoothly
control zooming, the power switch lever can turn the digital camera ON/OFF, and that the mode dial
can control the mode dial of the camera.
EN 16
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION:
• Before loading the digital camera, attach the zoom and focus gears to the Case’s zoom and focus rings.
Refer to the instruction manual provided with the optional underwater lens port for details.
• If the zoom and focus gears on the lens are not properly meshed with the Case’s zoom dial gear, zooming
and focusing are not possible. Even when the gears are meshed, the zoom and focus control ranges may
be limited due to the positioning of the zoom and focus gears in the Case. Be sure to carefully follow the
instructions provided with optional underwater lens port to ensure that correctly position the gears.
4 Insert the silica gel
Before sealing the Case, be sure to insert the silica gel bag in the space between the bottom of the
camera table and the inner surface of the Case. This will prevent fogging. Inset the silica gel bag
laterally with the sides folded down.
Pay attention to the orientation.
CAUTION:
• If the bag is only inserted part of the way, it will get caught by the O-ring when you try to seal the Case and
water will leak into the Case.
• Once silica gel has been used, the moisture absorption performance will be impaired. Always change the
silica gel when you open or close the Case.
Check the loading status
En
Always perform the following checks before sealing the Case.
• Is the eyecup removed correctly?
• Does maintenance of the O-ring perform properly?
• Does the zoom dial operate properly?
• Is the silica gel inserted all the way at the specified position?
• Are the O-rings and the O-ring contact surfaces free of dirt and other foreign matter?
• Are the O-rings installed properly?
• When using an external electronic flash with a TTL cable, check that the hot shoe cable is connected
properly and that the camera’s automatic pop-up setting is set to OFF.
• When using the UFL-2 underwater electronic flash with the underwater optical fiber cable, or when
using a slave flash from a non-Olympus manufacture, check that the camera's built-in flash is popped
up.
EN 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Seal the Case
1 Close the rear lid gently (so that the O-rings do not slip
out of the grooves).
2 Turn the open/close dial clockwise.
• The Case is sealed when the position of the slide lock
is at the top.
CAUTION:
If the open/close dial is not fully turned, the Case will not be sealed airtight and water leakage may occur.
Check the operation of the loaded camera
After sealing the Case, check that the camera functions normally.
• Operate the power switch lever on the Case and confirm that the camera can be turned ON/OFF.
• Turn the mode dial knob on the Case and confirm that the camera mode switches properly.
• Operate the shutter lever on the Case and confirm that the camera shutter is released.
• Operate the zoom dial on the Case and confirm that the camera’s lens is controlled.
• Operate other control buttons on the Case and confirm that the camera functions properly as intended.
Perform the final checks
Visual Inspection
After closing the case tightly, check the seal between the front and rear lids and the connection between
the port and case to make sure the O-rings are not twisted, that they sit properly in the grooves, and that
no foreign matter has been caught between the two parts.
En
CAUTION:
Hair, fiber, and other narrow items are not very apparent, but they may cause entry of water, therefore special
attention is required.
EN 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Leakage Test
The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. The required time is about five minutes.
Simple water leakage test
Explanatory image
Hints
As the rear lid of the Case is transparent,
waterdrops entering into it can be confirmed
easily.
1 Place the Case slowly into
the water.
In case of trouble with the O-ring, three
seconds is enough for water to enter. Are there
air bubbles coming out between the lids?
2 At first, immerse the Case
for only three seconds.
Remove the Case from the water and check
that no water has leaked at the inside of the
Case.
3 Check that no water has
entered the Case.
Check carefully for air bubbles!
Do not perform any operation yet, but just
observe.
4 Next, immerse the Case for
30 seconds.
Remove the Case from the water and check
that no water has leaked at the bottom of the
Case.
5 Check that no water has
entered the Case.
En
Check carefully for air bubbles!
Try operation of the buttons used frequently.
Check carefully for air bubbles!
6 Next, check by immersing
for three minutes.
7 This is the final check. Has
Has the silica gel become moist?
Please check carefully!
the silica gel become moist?
8 If there is no water leakage
and everything is functioning
correctly, you are ready to
start shooting underwater.
Now everything is all right!
EN 19
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Handling After Shooting
Wipe off any waterdrop
After underwater shooting, remove any drops of water from the case. Use pressurized air or a soft, lint-
free cloth to carefully wipe away any moisture from the hinge between the front and rear lids, the shutter
release lever, the handgrip and the open/close dial.
CAUTION:
Water left between the front and rear lids or between the case and port can get inside the case once it is
opened or the port is detached. Please dry these areas carefully.
Unload the digital camera
First, open the open/close dial of the Case and then open the rear lid carefully. Disconnect the hot shoe
cable if it is connected to the camera, then remove the Case’s zoom and mode dials so that they do not
interfere with removal of the camera. Gently remove the loaded digital camera, while holding it with both
hands.
CAUTION:
• When opening the case or removing the port, make sure no water from outside (e.g. drops from your hair
or the diving suit) gets inside the case and/or on the camera!
• Before opening the case or removing the port, ensure that your hands or gloves are completely clean (free
of sand, loose fibers, etc.).
• Never open the case or remove the port in areas where water could splash or spray or where sand or dust
could be blown in the air. When this cannot be avoided, for example if the battery or memory card needs to
be changed, the case and camera should be protected from the wind or spray with a plastic sheet or similar
object.)
• Never touch the digital camera and/or battery when your hands are wet with sea water.
Wash the Case with pure water
En
After use, seal the Case again after taking out the camera and wash it sufficiently in pure water as soon
as possible.
After use in sea water, it is effective to immerse it for a fixed time (30 minutes to 1 hour) in pure water to
remove any salt.
CAUTION:
• Water leakage may be caused when a high water pressure is applied locally. Before washing the Case with
water, remove the digital camera from it.
• Operate the shutter lever and various buttons of this product in pure water to remove salt adhering to the
shaft. Do not disassemble for cleaning.
• Letting salt dry on the case may impair the function. Always wash off any salt after use.
EN 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Dry the Case
After washing with pure water, use a lint-free soft cloth without any salt on it to wipe off any waterdrop
and dry the Case completely at a well ventilated location in the shade.
CAUTION:
Do not use hot air from a hair drier or the like for drying and do not expose the Case to direct sunlight, as this
may accelerate deterioration and deformation of the Case and deterioration of the O-ring, leading to leakage
of water.
When wiping the Case, take care not to cause scratches.
En
EN 21
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Maintaining the Waterproof Function
The O-ring is a consumable product. Before each use, perform proper maintenance. Always be sure to
perform the O-ring maintenance operation as described below. Neglecting this maintenance may
become the cause of water leakage.
Perform at the location without sand or dust, after washing and drying your hands.
Remove the O-ring
Open the Case and remove the O-ring.
Procedure
1 Insert the O-ring remover into the gap between the O-ring and O-ring groove wall.
2 Bring the tip of the inserted O-ring remover below the O-ring. (Be careful not to damage the groove
with the tip of the O-ring remover.)
3 Lift the O-ring, pinch it with your fingertips and pull it out of the Case.
Remove any sand, dirt, etc.
After visually checking that dirt has been removed from the O-ring, check for attached sand and other
foreign matter, as well as for damage and cracks by squeezing the entire circumference of the O-ring
lightly with your fingertips.
Remove attached foreign matter from the O-ring groove with a clean cloth or a cotton swab. Also remove
any sand or dirt attached to any part of the Case that comes into contact with the O-ring.
CAUTION:
• When a sharp object is used to remove the O-ring or to clean the inside of the O-ring groove, the Case and
the O-ring may be damaged and water leakage may be caused.
• When the O-ring is checked with the fingertips, take care not to stretch the O-ring.
• Never use alcohol, thinner, benzene or similar solvents or chemicals detergents to clean the O-ring. When
such chemicals are used, it is likely that the O-ring will be damaged or that its deterioration will be
accelerated.
En
Install the O-ring
Confirm that no foreign matter is attached, apply a thin coat of the accessory grease to the O-ring, and
fit the O-ring into the groove. At this time, confirm that the O-ring does not stick out from the groove.
EN 22
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Apply Grease to the O-ring
Make sure that your fingers and the O-ring are
free of dirt, and squeeze about 5 mm of
lubricant onto a finger. (5 mm is the most
appropriate amount.)
1 Apply only Olympus
exclusive lubricant to each
O-ring.
Spread the grease onto the entire
circumference of the O-ring using 3 fingers.
Be careful not to use excessive force as this
may stretch the O-ring.
2 Spread the lubricant onto
the entire circumference of
the O-ring.
After spreading the lubricant, check visually
and by touch that the O-ring is not scratched
and that its surface is flat. If it is damaged in
any way, replace it with a brand-new O-ring.
3 Check that the O-ring is free
of scratches or unevenness.
4 Apply lubricant on the O-ring
Use the lubricant remaining on the fingers to
clean and lubricate the case’s contact surface.
contact surface.
CAUTION:
• Always perform maintenance of the waterproof function even when the Case has been opened every
shooting. Neglecting this maintenance may become the cause of water leakage.
• When the Case is not to be used for a long time, remove the O-ring from the groove to prevent deformation
of the O-ring, apply a thin coat of silicone grease, and store it in a clean plastic bag or the like.
Examples of foreign matter sticking to the O-ring
En
Hair
Fibers
Grains of sand
EN 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Replace consumable products
• The O-ring is a consumable product. Independent of the number of times the Case is used, it is
recommended that the O-ring should be replaced by a new piece at least once a year.
• Deterioration of the O-ring is accelerated by the usage conditions and the storage conditions. Replace
the O-ring even before a year has passed if it shows signs of damage, cracking or loss of elasticity.
CAUTION:
• Please use genuine Olympus silicone grease, silica gel and O-ring.
• Do not try to replace the O-ring by yourself.
• We recommend to perform the check periodically.
Maintenance of the threaded sections on the TTL cable and TTL
cable connector
If the threaded sections used to connect the TTL cable to the TTL cable connector are not maintained
properly, salt and other seawater residue may adhere to the TTL cable and prevent it from being
disconnected.
After use in seawater, clean off any salt, sand, or other residue as soon as possible, then dry the
equipment thoroughly. Clean the threaded sections with a cotton swab and apply a thin, uniform layer of
silicone grease (provided with this case).
Clean and apply silicone grease to these
sections.
Maintenance of the TTL Connector Cap
After removing the TTL connector cap from the Underwater Case, be sure to clean and grease the O-
ring.
Use the maintenance adapter to remove the O-ring unit from the TTL connector cap.
En
TTL connector cap
Maintenance adapter
1 Insert the adapter by aligning its pin with the hole on
the cap.
2 Turn the adapter counterclockwise to remove the O-
ring unit.
3 After removing the O-ring attached to the O-ring unit,
clean the O-ring groove and apply silicone grease to
the O-ring. Then, re-attach the O-ring to the O-ring
unit.
O-ring
*
Reverse the removal procedure to re-attach the O-ring unit to the TTL connector cap.
EN 24
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Appendix
Specifications
Available models
Olympus Digital Camera E-620
Pressure
Depth of down to 40 m (130 feet)
resistance
Main materials
Main body: Polycarbonate resin.
Open/close dial/release lever/power switch dial/mode dial/control dial/zoom dial/
camera table: Polycarbonate resin.
Port mount/pickup viewfinder frame/optional bracket mount/zoom dial gear/TTL
connector cap: Aluminum.
Axis of operation buttons/hand strap ring: Stainless steel.
Body cap: ABS resin.
O-rings/LCD inner hood: Silicone rubber.
LCD hood: NBR rubber.
Dimensions
Weight
Width 208.0 mm x height 169.0 mm x depth 144.0 mm
1,340 g (camera and accessories not included)
*
We reserve the right to change the external appearance and the specifications without notice.
Supplied accessories for PT-E06
O-ring (for back lid): POL-E06A
O-ring (for front lid): POL-E06B
Silicone grease: PSOLG-2
Silica gel: SILCA-5S
LCD hood: PFUD-E06
Camera stand: PTMO-E05
Hand strap: PST-E02
Body cap: PBC-E02
TTL connector cap: PTAC-E04
En
EN 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Waterproof Port
Waterproof
Port
Withstanding
depth
Applicable Lens
14-45 mm
Note
Packaged with the PPZR-E01 underwater zoom
gear for 14-45 mm lens.
The provided PPZR-E01 zoom gear cannot be used.
The focus ring rotation angle can be increased to
360° by using the optional PPZR-E04 underwater
focus gear. The magnification immediately in front of
the objective is about x0.6.
PPO-E01
60 m
35 mm Macro
14-54 mm
14-54 mm II
Packaged with the PPZR-E02 underwater zoom
gear for 14-54 mm, 14-54 mm II or 11-22 mm lens.
PPO-E02
PPO-E03
60 m
60 m
11-22 mm
Manual focusing is possible using the provided
PPZR-E01, but the focus ring rotation angle is
limited to 180°.
The focus ring rotation angle can be increased to
360° by using the optional PPZR-E04 underwater
focus gear.
50 mm Macro
When using the EC-14, attach it between the
underwater lens port and PT-E series case.
Zooming of the lens and manual focus cannot be
operated when using EC-14.
PER-E01
60 m
60 m
EC-14
PPO-E04
+PER-E02
The PPZR-E03 underwater zoom gear for 7-14 mm
lens is provided with the PER-E02.
7-14 mm
The focus ring angle can be rotated by 360° by using
the optional PPZR-E05 underwater focus gear.
8 mm Fisheye
9-18 mm Fisheye
14-42 mm
PPO-E04
60 m
40 m
The zoom can be operated by using the optional
PPZR-E07 dedicated gear.
Packaged with the PPZR-E06 underwater zoom
gear for 14-42 mm lens.
PPO-E05
When the waterproof port is used in combination with a PT-E06, the maximum depth that the combination can
be used at is 40 m, as specified for the waterproof port. This is true even when the PT-E06 is specified for use
at depths up to 60 m.
En
Optional accessories
Silicone grease: PSOLG-3
Underwater optical fiber cable: PTCB-E02
TTL cable: PTCB-E01
Hot shoe cable: PHCB-01
Bracket: PTBK-E01, PTBK-E02
* When use combining PTBK-E01 and the Case, the dedicated washers are necessary in the screw part.
If you have PTBK-E01 to which dedicated washers are not bundled, please contact to customer support
center.
Accessories can be purchased. Products of other model types than those describing above cannot be used.
EN 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
Download from Www.Somanuals.com. All Manuals Search And Download.
©2009
Printed in China
VN212101
Download from Www.Somanuals.com. All Manuals Search And Download.
|