Download from Www.Somanuals.com. All Manuals Search And Download.
Owner's Guide
CONTENTS
WARNINGS ................................................................................................... 2
NOTICES AND WARRANTY......................................................................... 2
INTRODUCTION ........................................................................................... 4
STATEMENT FOR COMPATIBILITY AND USE WITH NITROX .................. 4
STATEMENT FOR COLD WATER DIVING.................................................. 5
REGULATOR FIRST STAGES...................................................................... 6
ATTACHMENT OF HOSES ......................................................................... 6
REMOVAL OF HOSES ................................................................................ 7
DATALINK ................................................................................................ 8
REGULATOR ATTACHMENT TO A TANK................................................... 8
ENVIRONMENTAL PROTECTION KIT ..................................................... 11
REGULATOR SECOND STAGES .............................................................. 11
FEATURES AND OPERATION ................................................................. 11
®
ALPHA 7 , GAMMA, PONY BOTTLE, AND EXPLORERS ................. 12
®
DELTA 3 AND GAMMA 2..................................................................... 12
OMEGA II AND OMEGA II WITH SWIVEL ........................................ 14
SECOND STAGE SWIVEL ........................................................................ 15
ZETA ...................................................................................................... 15
SLIMLINE OCTOPUS ............................................................................ 15
SWIVEL 180 OCTOPUS ........................................................................ 15
CARE AND MAINTENANCE ....................................................................... 16
ADDITIONAL SPECIFICATIONS ................................................................ 17
GUIDELINES FOR MINIMUM SERVICE INTERVALS ............................... 18
RECORDS ................................................................................................... 19
INSPECTIONS AND SERVICE ................................................................... 19
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Oceanic Regulator
INTRODUCTION
STATEMENT FOR
OCEANIC REGULATOR EQUIPMENT
COMPATIBILITY AND USE WITH NITROX
WARNINGS:
Oceanic Regulators are not intended to be used by untrained per-
sons who may not know the inherent risks and hazards of SCUBA
diving.
Prior to use of Oceanic Regulator equipment with nitrogen-oxygen
(Nitrox) breathing gas mixtures that contain a higher fraction of
oxygen than 21%, the user must have received, or must first ob-
tain, certification in diving with Nitrox from a recognized training
agency.
An Oceanic Regulator is not a medical device. It is not intended
and must not be used to supply treatment oxygen in a medical
emergency.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Owner's Guide
NOTE: The term breathing gas used throughout this owner's
guide applies to enriched nitrogen-oxygen (Nitrox) mixtures as
well as compressed Air.
When using Air with this regulator equipment, the Air used must
meet EN132 Annex A standards.
STATEMENT FOR
OCEANIC REGULATOR EQUIPMENT
COLD WATER DIVING
WARNING: Installation of an Environmental Protection Kit must
be performed by the Oceanic factory or an Authorized Oceanic
Dealer. Improper installation may cause First Stage failure while
underwater resulting in serious injury or death.
WARNING: Failure to obtain proper training in the specialized
techniques required for diving in cold water environments and
failure to apply such techniques to handle situations that could re-
sult in Regulator freezing will place you in risk of serious injury or
death.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Oceanic Regulator
REGULATOR FIRST STAGES
WARNING: Failure to prepare your First Stage properly for use in
harsh environmental conditions, such as being subjected to sedi-
ment or the possible buildup of ice, or salt crystals, may result
in serious injury or death.
WARNING: Under no circumstances should adjustment of an
Oceanic first stage regulator be performed by anyone other than
an Authorized Oceanic Dealer. Doing so may cause failure under-
water, resulting in serious injury or death.
ATTACHMENT OF HOSES
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Owner's Guide
REMOVAL OF HOSES
WARNING: At least one second stage must be connected to the
first stage to facilitate purging of breathing gas from the first
stage.
DATALINK
WARNING: Proper installation of the DataLink is essential for it to
function properly. It must be installed only by an Authorized Oce-
anic Dealer.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Oceanic Regulator
NOTE: Once the DataLink has been disconnected, the regulator
system can again be pressurized.
REGULATOR ATTACHMENT TO A TANK
WARNING: Maximum working pressure for an Oceanic Yoke style
connector is 3500 PSI / 232 BAR and for a DIN style connector is
4500 PSI / 300 BAR
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Owner's Guide
DIN WHEEL STYLE CONNECTOR
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Oceanic Regulator
DIN TO USA CONVERTER YOKE
WARNING: The DIN to USA Converter is specifically designed for
use with Oceanic brand first stages. Although it may fit other
brand first stages, it was not designed to do so or tested for use
with other brands. Under no circumstances should the Oceanic
DIN to USA Converter be used with any other first stage than an
Oceanic model.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Owner's Guide
ENVIRONMENTAL PROTECTION KIT
WARNING: Installation of an Environmental Kit must be per-
formed by an Authorized Oceanic Dealer. Improper installation
may cause first stage failure while underwater resulting in serious
injury or death.
REGULATOR SECOND STAGES
WARNING: Even if your First Stage is properly prepared for use
in harsh environmental conditions, only proper training will pro-
tect your Second Stage from the effects of the environment.
FEATURES AND OPERATION
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Oceanic Regulator
Alpha 7, Gamma, Pony Bottle, and Explorers (Primary and Octopus)
NOTE: If these second stages are shipped from the factory spe-
cifically as an Octopus, the inhalation effort is set slightly higher
to reduce sensitivity.
Delta 3 and Gamma 2 (Primary and Octopus)
Pre-Dive/Dive Switch (on top):
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Owner's Guide
Delta 3 Adjustment Knob (on side):
Guidelines for Delta 3adjustments (knob on side):
NOTE: Rotation of the Delta 3 adjustment knob does not rotate
the poppet seat against the sealing orifice.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Oceanic Regulator
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Owner's Guide
NOTE: Due to the Zeta's servo design, a hiss may be heard upon
being pressurized. This is normal for the Zeta.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
Oceanic Regulator
CARE AND MAINTENANCE
TRANSPORT and STORAGE
POST DIVE CARE
REPAIRS and SERVICE
WARNING: DO NOT attempt to disassemble or repair the first or
second stages, or to adjust the first stage. Doing so could cause
malfunction while underwater resulting in serious injury or death.
It will also void the regulator's limited warranty.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Owner's Guide
ADDITIONALSPECIFICATIONS
FOR CONNECTING COMPONENTS TO
OCEANIC REGULATOR FIRST STAGES
Second Stage (Primary or Octopus):
Pressure Gauge or Pressure Transmitter:
Download from Www.Somanuals.com. All Manuals Search And Download.
17
Oceanic Regulator
GUIDELINE FOR
OCEANIC REGULATOR EQUIPMENT
MINIMUM SERVICE INTERVALS
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Owner's Guide
RECORDS
First Stage Model
First Stage Serial#
Second Stage Model
Second Stage Serial#
Octopus Model
________________________________
________________________________
________________________________
________________________________
________________________________
________________________________
________________________________
________________________________
________________________________
Octopus Serial#
Date of Purchase
Oceanic Dealer
Dealer Phone No.
INSPECTIONS / SERVICE
Date
Service
Authorized Dealer / Technician
Download from Www.Somanuals.com. All Manuals Search And Download.
19
OCEANIC WORLD WIDE
OCEANIC USA
2002 Davis Street
San Leandro, CA 94577
Tel: 510/562-0500
Fax: 510/569-5404
Oceanic Central/North Europe
Wendelstein, Germany
Tel: 09129-9099780 Fax: 09129-9099789
E-mail: [email protected]
Oceanic South Europe
Genova, Italy
Tel: 0039-010-8382006 Fax: 0039-010-8365360
E-mail: [email protected]
Oceanic SW, Ltd
Devon, United Kingdom
Tel: 44-1-404-89-1819 Fax: 44-1-404-89-1909
E-mail: [email protected]
Oceanic France
Marseille, France
Tel: 0033.491.25.37.78 Fax: 0033.491.72.34.48
E-mail: [email protected]
Oceanic Diving Australia Pty. Ltd
Sorrento, Victoria, Australia
Tel: 61-3-5984-4770 Fax: 61-3-5984-4307
E-mail: [email protected]
Oceanic Asia-Pacific Pte. Ltd
Singapore
Tel: 65-6391-1420 Fax: 65-6297-5424
E-mail: [email protected]
Oceanic Japan
Yokohama, Japan
Tel: 045-575-6671 Fax: 045-575-6673
E-mail: [email protected]
Oceanic International (Pacific)
Kapolei, Hawaii
Tel: 808-682-5488 Fax: 808-682-1068
E-mail: [email protected]
© 2002 Design, 1996
Doc. No. 12-2018-r08 (6/22/06)
Download from Www.Somanuals.com. All Manuals Search And Download.
|