Oceanic Scuba Diving Equipment 04106107 User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
LIMITED TWO-YEAR WARRANTY ............................................................................................................................ 2  
NOTICES ..................................................................................................................................................................... 2  
DECOMPRESSION MODEL ....................................................................................................................................... 2  
FEATURES AND DISPLAYS............................................................................................. 7  
INTERACTIVE CONTROL CONSOLE ....................................................................................................................... 8  
BAR GRAPHS ............................................................................................................................................................. 9  
Tissue Loading Bar Graph (TLBG)......................................................................................................................... 9  
Oxygen Bar Graph (O2BG) .................................................................................................................................. 10  
Variable Ascent Rate Indicator (VARI) .................................................................................................................. 10  
Air Time Remaining Bar Graph (ATRBG) ............................................................................................................. 11  
DIVE TIME REMAINING ........................................................................................................................................... 11  
ALPHA / NUMERIC DISPLAYS ................................................................................................................................. 12  
Cylinder Pressure ................................................................................................................................................. 12  
Depth Displays ...................................................................................................................................................... 12  
Time and Date Displays ....................................................................................................................................... 13  
Temperature Display ............................................................................................................................................. 13  
AUDIBLE ALARM ...................................................................................................................................................... 14  
LED Warning Light ............................................................................................................................................... 14  
SMARTGLO BACKLIGHT ........................................................................................................................................ 16  
POWER SUPPLY ...................................................................................................................................................... 16  
Battery Consumption Indicator ............................................................................................................................. 16  
Low Battery Condition .......................................................................................................................................... 17  
FO2 MODE ................................................................................................................................................................ 18  
FO2 50% Default .................................................................................................................................................. 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
CONTENTS (continued)  
ACTIVATIONAND SETUP .............................................................................................. 21  
ACTIVATION .............................................................................................................................................................. 22  
SURFACE MODE ...................................................................................................................................................... 23  
Accessing Other Modes ....................................................................................................................................... 23  
SET MODES .............................................................................................................................................................. 24  
ENTERING SETTINGS -SET MODE #1 .............................................................................................................. 25  
ENTERING SETTINGS -SET MODE #2 .............................................................................................................. 29  
PLAN AND DIVE MODES ............................................................................................... 45  
TM  
PRE DIVE PLANNING SEQUENCE  
.................................................................................................................... 46  
TISSUE LOADING BAR GRAPH .............................................................................................................................. 48  
OXYGEN ACCUMULATION BAR GRAPH ............................................................................................................... 49  
VARIABLE ASCENT RATE INDICATOR .................................................................................................................. 49  
AIR TIME REMAINING BAR GRAPH BAR GRAPH ................................................................................................ 50  
CONTROL OF DISPLAYS ......................................................................................................................................... 50  
NO DECOMPRESSION DIVE MODE ....................................................................................................................... 51  
DECOMPRESSION DIVE MODE .............................................................................................................................. 54  
VIOLATION MODES .................................................................................................................................................. 57  
Conditional Violation Mode ................................................................................................................................... 57  
Delayed Violation Modes ...................................................................................................................................... 59  
Immediate Violation Mode and Gauge Mode ....................................................................................................... 60  
HIGH PO2 DIVE MODE ............................................................................................................................................. 62  
HIGH OXYGEN ACCUMULATION ............................................................................................................................ 63  
USER SET DIGITAL GAUGE MODE ........................................................................................................................ 64  
UNEXPECTED LOSS OF DISPLAYED INFORMATION .......................................................................................... 64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
CONTENTS (continued)  
POST DIVE MODES ....................................................................................................... 65  
POST DIVE SURFACE MODE .................................................................................................................................. 66  
TRANSITION PERIOD .............................................................................................................................................. 66  
AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS) .................................................................................. 68  
To activate the Backlight - .................................................................................................................................... 68  
To access the Pre Dive Planning Sequence - ...................................................................................................... 68  
To access the Time to Fly Countdown ................................................................................................................. 69  
To access the Time to Desaturate Countdown .................................................................................................... 69  
Log Mode .............................................................................................................................................................. 70  
AFTER THE FIRST 2 HOURS .................................................................................................................................. 72  
WET CONTACTS ....................................................................................................................................................... 73  
DOWNLOADING DATA TO A PC .............................................................................................................................. 74  
SIMULATOR (DEMO) MODE .......................................................................................... 75  
GENERAL ....................................................................................................................... 83  
CARE AND CLEANING ............................................................................................................................................. 84  
INSPECTIONS AND SERVICE ................................................................................................................................. 84  
BATTERY REPLACEMENT ...................................................................................................................................... 86  
SPECIFICATIONS ..................................................................................................................................................... 90  
OCEANIC WORLD WIDE ......................................................................................................................................... 96  
SERVICE RECORD ................................................................................................................................................... 97  
RESET PROCEDURE ............................................................................................................................................... 99  
Pay special attention to items marked  
with this Warning symbol.  
WARNING: Prior to diving with the Pro Plus 2, you must also read and  
understand the Oceanic Dive Computer Safety and Reference Manual.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Components:  
a. Select (right) Button  
b. LED Warning Light  
m
c. Smartglo Sensing Port  
d. Advance (front) Button  
e. Air Time Remaining Bar Graph  
f. O2 (oxygen) Bar Graph  
g. Icon - Descend Arrow  
Icon - Decompression Ceiling  
Icon - Ascend Arrow  
h. Graphic - Maximum Depth  
i. Tissue Loading Bar Graph  
j. Battery Indicator  
n
l
o
DECO  
N
M
p
k
j
FEET  
MAX  
TOO  
FAS T  
q
DEMO  
i
k. Icon - Alarm (Set Mode)  
l. Icon - Log Mode  
MAX  
m. Graphic - Demo Mode  
n. Graphic - Depth  
h
r
o
Graphic - Ascent Too Fast  
g
O2  
p. Icon - Time  
q. Variable Ascent Rate Indicator  
r. Icon - Operating Mode  
O2  
O2  
P SI  
BAR  
f
0
5
ATR  
1 0  
2 0  
3 0 4 0  
5 0 6 0  
e
a
d
b
c
PRO PLUS 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
FEATURES and DISPLAYS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INTRODUCTION  
INTERACTIVE CONTROL CONSOLE  
DECO  
N
M
FEET  
MAX  
TOO  
FAS T  
DEMO  
MAX  
O2  
O2  
O2  
0
P SI  
BAR  
5
1
0
2
0
3
0
4
0
5
0
6
0
ATR  
a
b
Fig. 1 - Interactive Control  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
BAR GRAPHS  
Tissue Loading Bar Graph (TLBG)  
DECO  
N2  
a
O2  
NOTE: Displays associated with oxygen and the  
O2 Bar Graph will only appear if FO2 has been set  
at a value other than 'Air' (e.g., a numerical value).  
ATR  
Fig. 2 - TLBG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Oxygen Accumulation Bar Graph (O2BG)  
Variable Ascent Rate Indicator (VARI)  
60 feet (18 m) & Shallower  
Deeper than 60 feet (18 m)  
Segments  
Ascent Rate =  
Segments  
Ascent Rate =  
DECO  
N2  
Displayed  
FPM  
0-10  
11-15 3.5-4.5  
16-20 5-6  
21-25 6.5-7.5  
26-30 8-9  
>30  
MPM  
0 - 3  
Displayed  
FPM  
0-20  
21-30 6.5-9  
31-40 9.5-12  
41-50 12.5-15  
51-60 15.5-18  
MPM  
0 - 6  
b
0
1
2
3
4
5
0
1
2
3
4
5
TOO  
FAS T  
>9  
>60  
>18  
a
Fig. 4 - VARI Values  
WARNING: At depths greater than 60 FT (18 M),  
ascent rates should not exceed 60 fpm (18 mpm). At  
depths of 60 FT (18 M) and shallower, ascent rates  
should not exceed 30 fpm (9 mpm).  
O2  
O2  
0
5
1 0  
2 0  
3 0 4 0  
5 0 6 0  
ATR  
Fig. 3 - O2BG and VARI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
N2  
Air Time Remaining Bar Graph (ATRBG)  
FEET  
b
O2  
P SI  
a
0
5
ATR  
1 0  
2 0  
Fig. 5 - ATRBG  
DIVE TIME REMAINING  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
ALPHA / NUMERIC DISPLAYS  
Cylinder Pressure Display  
Depth Displays  
b
N2  
FEET  
MAX  
c
O2  
P SI  
0
5
1 0  
2 0  
ATR  
a
Fig. 6 - Cylinder Pressure  
and Depth Displays  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Time and Date Displays  
b
N2  
FEET  
Temperature Display  
c
a
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 7 - Time and Temperature  
Displays  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
NOTE: Each numeric and graphic display represents a unique piece of  
information. It is imperative that you understand the formats, ranges, and  
values of the information represented to avoid any possible misunderstand-  
ing that could result in error. The Informational Displays are described in  
detail as the various operating modes they appear in are presented through-  
out this manual.  
AUDIBLEALARM  
LED Warning Light  
A single short beep (which cannot be disabled) is emitted for the following -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Situations that will sound the Alarm, if it is turned ON (a user setting), include -  
During the following situations, the 10 second continuous tone will be followed by  
a 5 second steady beep that will not turn off when acknowledged, even if it was  
user Set OFF -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
SMARTGLO® BACKLIGHT  
NOTE: Extensive use of the Backlight reduces  
estimated Battery life. Also, the Backlight does not  
operate during a Low Battery Condition or when  
downloading data to a PC.  
a
POWER SUPPLY  
N2  
Battery Indicator  
O2  
ATR  
Fig. 8 - Battery Indicator  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Low Battery Condition  
N2  
O2  
P SI  
ATR  
Fig. 9 - Low Battery Condition  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
FO2 MODE  
N2  
O2  
ATR  
Fig. 10 - FO2 set for AIR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
N2  
MAX  
O2  
ATR  
Fig. 11 - FO2 set for 21%  
FO2 50% Default  
N2  
O2  
ATR  
Fig. 12 - FO2 Default ON  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
WARNING: When the unit shuts off, the FO2 set  
point will default to AIR regardless if the 50%  
Default is set ON or OFF. Always set, or verify, the  
FO2 set point prior to each nitrox dive.  
Setting FO2 for a nitrox dive is described on page  
25.  
N2  
O2  
ATR  
Fig. 13 - FO2 Default OFF  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
ACTIVATION and SETUP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
ACTIVATION  
Backup Activation (only if Water Activation is set ON)  
DECO  
N2  
M
FEET  
MAX  
TOO  
FAS T  
DEMO  
MAX  
WARNING: If the unit is manually activated at eleva-  
tions higher than 14,000 feet (4,267 meters), it will  
perform a diagnostic check followed by immediate  
shutdown.  
O2  
O2  
O2  
P SI  
BAR  
0
5
1 0  
2 0  
3 0 4 0  
5 0 6 0  
ATR  
Fig. 14 - Diagnostic Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
SURFACE MODE  
N2  
NOTE: If the wet contacts are bridged, the graphic  
O2  
P SI  
'H2O' will appear in place of the dive number '0'  
(Fig. 16). After the unit is rinsed and dried, '0' will  
replace 'H2O'.  
ATR  
Fig. 15 - Surface Mode  
N2  
Accessing Other Modes  
O2  
P SI  
ATR  
Fig. 16 - Surface Mode  
(rinse and dry the unit)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
SET MODES  
N2  
O2  
ATR  
Fig. 17 - Set Mode 1  
N2  
O2  
ATR  
Fig. 18 - Set Mode 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
N2  
ENTERING SETTINGS -SET MODE #1  
O2  
ATR  
Fig. 19 - Set FO2  
N2  
MAX  
a
O2  
ATR  
Fig. 20 - FO2 set for 32%  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
N2  
FEET  
MAX  
O2  
ATR  
Fig. 21 - Set Max Depth Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
N2  
O2  
ATR  
Fig. 22 - Set Elapsed Dive  
Time Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
NOTE: For more  
information  
regarding PC  
Interface, refer  
to page 74 of  
this manual and  
to documents  
provided with  
the PC down-  
load product.  
N2  
O2  
ATR  
Fig. 23 - PC Interface  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
ENTERING SETTINGS -SET MODE #2  
N2  
O2  
ATR  
Fig. 24 - Set Units of Measure  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
N2  
O2  
ATR  
Fig. 25 - Set Hour Format  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
N2  
O2  
ATR  
Fig. 26 - Set Hour  
N2  
O2  
ATR  
Fig. 27 - Set Minute  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
N2  
Fig. 28 - Set Year  
N2  
Fig. 29 - Set Month  
N2  
Fig. 30 - Set Day  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32  
N2  
O2  
ATR  
Fig. 31- Set Audible Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
DECO  
N2  
O2  
ATR  
Fig. 32 - Set Max TLBG Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34  
N2  
O2  
0
5
1 0  
2 0  
3 0 4 0  
5 0 6 0  
ATR  
Fig. 33 - Set Air Time Remaining  
Bar Graph Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
N2  
O2  
P SI  
ATR  
Fig. 34 - Set Turn Pressure Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36  
N2  
O2  
P SI  
ATR  
Fig. 35 - Set End Pressure Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
37  
N2  
O2  
ATR  
Fig. 36 - Set Dive Time  
Remaining Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38  
N2  
MAX  
O2  
ATR  
Fig. 37 - Maximum PO2 Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
N2  
O2  
ATR  
Fig. 38 - Set FO2 50% Default  
Download from Www.Somanuals.com. All Manuals Search And Download.  
40  
N2  
O2  
ATR  
Fig. 39 - Set Backlight Duration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
NOTE: Sampling  
Rate is the interval  
at which data  
samples are  
recorded during a  
dive for subse-  
quent download to  
the PC program.  
This setting has  
no effect on  
displayed data or  
data in the unit's  
viewable Log.  
N2  
O2  
ATR  
Fig. 40 - Set PC Sampling Rate  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42  
NOTE: Once a dive  
is made with this  
feature set ON, the  
setting will be  
locked ON for 24  
hours after the dive.  
Set Digital Gauge  
Mode will not  
appear as a selec-  
tion during that 24  
hour period.  
N2  
O2  
ATR  
Fig. 41 - Set Digital Gauge Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
43  
WARNING: If this  
feature is set for  
OFF, the Pro Plus 2  
must be manually  
activated prior to  
commencing a dive.  
N2  
O2  
ATR  
Fig. 42 - Set Water Activation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
44  
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
PLAN and DIVE MODES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
45  
PRE DIVE PLANNING SEQUENCETM  
Depth  
NDL  
feet (meters)  
hours:mins  
30 (9)  
4:20 (4:43)  
2:17 (2:24)  
1:21 (1:25)  
40 (12)  
50 (15)  
60 (18)  
70 (21)  
80 (24)  
90 (27)  
100 (30)  
110 (33)  
120 (36)  
130 (39)  
140 (42)  
150 (45)  
160 (48)  
170 (51)  
180 (54)  
190 (57)  
:57  
:40  
:30  
:24  
:19  
:16  
:13  
:11  
:09  
:08  
:07  
:07  
:06  
:05  
(:59)  
(:41)  
(:32)  
(:25)  
(:20)  
(:17)  
(:14)  
(:11)  
(:09)  
(:08)  
(:07)  
(:06)  
(:06)  
(:05)  
No Decompression Limits  
for an Air Dive  
(no dive made yet)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
N2  
FEET  
MAX  
O2  
ATR  
Fig. 43 - Nitrogen Control  
N2  
FEET  
MAX  
O2  
O2  
ATR  
Fig. 44 - Oxygen Control  
Download from Www.Somanuals.com. All Manuals Search And Download.  
47  
NOTE: The Pro Plus 2 will store oxygen accumula-  
tion calculations for up to 10 dives conducted  
during a 24 hour period. If the maximum limit for  
oxygen loading has been exceeded for that day (24  
hour period), all of the segments of the O2 bar  
graph will be displayed flashing .  
Depth/Time values will not appear until the O2 bar  
graph recedes into the green (normal) zone (i.e.,  
your daily oxygen dosage decreases an amount  
equivalent to the amount accumulated during the  
latest dive completed).  
a
TISSUE LOADING BAR GRAPH (Fig. 45a)  
N2  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 45 - Tissue Loading Bar  
Graph  
Download from Www.Somanuals.com. All Manuals Search And Download.  
48  
N2  
OXYGEN ACCUMULATION BAR GRAPH (Fig. 46a)  
FEET  
a
b
VARIABLE ASCENT RATE INDICATOR (Fig. 46b)  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 46 - O2 Bar Graph & VARI  
N2  
FEET  
TOO  
FAS T  
O2  
P SI  
NOTE: Refer to page 10 for additional information  
pertaining to the Variable Ascent Rate Indicator.  
0
5
ATR  
1 0  
2 0  
3 0  
Fig. 47 - Ascent Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
49  
AIR TIME REMAINING BAR GRAPH  
N2  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
a
Fig. 48 - Air Time Remaining  
Bar Graph  
CONTROL OF DISPLAYS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
50  
NO DECOMPRESSION DIVE MODE  
No Deco  
Mode icon  
N2  
FEET  
No Deco Dive Mode - Display #1 (Fig. 49)  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 49 - No Deco #1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
51  
N2  
No Deco Dive Mode - Display #2 (Fig. 50)  
FEET  
MAX  
O2  
P SI  
No Deco Dive Mode - Display #3 (Fig. 51)  
0
5
ATR  
1 0  
2 0  
Fig. 50 - No Deco #2  
N2  
FEET  
(lower portion same as Fig. 50)  
Fig. 51 - No Deco #3  
No Deco Dive Mode - Display #4 (Fig. 52)  
N2  
FEET  
(lower portion same as Fig. 50)  
Fig. 52 - No Deco #4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
52  
N2  
No Deco Dive Mode - Secondary Display (Fig. 53)  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
No Deco Dive Mode - SAFETY STOP (Fig. 54)  
Fig. 53 - No Deco Secondary  
N2  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
3 0  
ATR  
Fig. 54 - No Deco Safety Stop  
Download from Www.Somanuals.com. All Manuals Search And Download.  
53  
DECOMPRESSION DIVE MODE  
Deco Mode icon  
DECO  
N2  
FEET  
Total Ascent Time  
a
O2  
P SI  
0
5
1 0  
ATR  
Fig. 55 - Entry into Deco Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
54  
Managing Decompression Stops  
c
DECO  
N2  
FEET  
b
Decompression Dive Mode - Main Display #1 (Fig. 56)  
a
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 56 - Deco #1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55  
DECO  
N2  
Decompression Dive Mode - Display #2 (Fig. 57)  
Decompression Dive Mode - Display #3 (Fig. 58)  
Decompression Dive Mode - Display #4 (Fig. 59)  
FEET  
MAX  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 57 - Deco #2  
DECO  
N2  
FEET  
(lower portion same as Fig. 57)  
Fig. 58 - Deco #3  
DECO  
N2  
FEET  
(lower portion same as Fig. 57)  
Fig. 59 - Deco #4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56  
VIOLATION MODES  
Conditional Violation Mode (Fig. 60)  
a
DECO  
N2  
FEET  
b
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 60 - Conditional Violation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
57  
NOTE: Upon entry into the following 3 Delayed  
Violation Modes, the red LED warning light will  
light and the Audible Alarm will sound, even if Set  
OFF. The Alarm cannot be acknowledged (si-  
lenced) by pressing the Left (Advance) button.  
Delayed Violation Mode #1 (Fig. 61)  
DECO  
N2  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 61 - Delayed Violation #1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
58  
DECO  
N2  
Delayed Violation Mode #2 (Fig. 62)  
FEET  
O2  
P SI  
0
5
1 0  
2 0  
3 0 4 0  
5 0  
ATR  
Fig. 62 - Delayed Violation #2  
N2  
FEET  
Delayed Violation Mode #3 (Fig. 63)  
MAX  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 63 - Delayed Violation #3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
59  
Immediate Violation Mode and Gauge Mode  
DECO  
N2  
FEET  
MAX  
O2  
O2  
P SI  
0
5
1 0  
ATR  
Fig. 64 - Immediate Violation  
Gauge Mode (underwater)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
60  
DECO  
N2  
O2  
Responsible  
O2  
P SI  
ATR  
Fig. 65 - Immediate Violation  
Gauge Mode (after surfacing)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
61  
N2  
HIGH PO2 DIVE MODE  
FEET  
O2  
O2  
0
P SI  
5
1 0  
2 0  
3 0  
ATR  
Fig. 66 - PO2 Warning  
N2  
FEET  
O2  
O2  
0
P SI  
5
1 0  
2 0  
3 0  
ATR  
Fig. 67 - PO2 Alarm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
62  
HIGH OXYGEN ACCUMULATION  
N2  
FEET  
O2  
O2  
O2  
0
P SI  
5
1 0  
ATR  
Fig. 68 - High O2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
63  
N2  
USER SET DIGITAL GAUGE MODE  
FEET  
MAX  
O2  
P SI  
0
5
1 0  
ATR  
Fig. 69 - User Set Gauge Mode  
UNEXPECTED LOSS OF DISPLAYED INFORMATION  
N2  
FEET  
MAX  
O2  
P SI  
0
5
1 0  
ATR  
Fig. 70 - User Set Gauge Mode  
(Air Time Remaining)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
64  
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
POST DIVE MODES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
65  
POST DIVE SURFACE MODE  
TRANSITION PERIOD  
N2  
O2  
P SI  
ATR  
Fig. 71 - Transition Period  
Download from Www.Somanuals.com. All Manuals Search And Download.  
66  
To view that dive's Log (Fig. 72) -  
N2  
O2  
ATR  
Fig. 72 - Log Mode  
(during Transition Period)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
67  
N2  
AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS)  
To activate the Backlight -  
O2  
ATR  
To access the Pre Dive Planning Sequence -  
Fig. 73 - Surface Mode (>10 min)  
N2  
FEET  
O2  
ATR  
Fig. 74 - Adjusted NDLs  
Download from Www.Somanuals.com. All Manuals Search And Download.  
68  
N2  
To access the Time to Fly Countdown (while in Surface  
Mode)  
O2  
ATR  
Fig. 75 - Time to Fly  
To access the Time to Desaturation Countdown  
(while in Surface Mode)  
N2  
O2  
ATR  
Fig. 76 - Time to Desaturate  
Download from Www.Somanuals.com. All Manuals Search And Download.  
69  
LOG MODE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
70  
N2  
O2  
ATR  
Fig. 77 - Log (Date / Time)  
N2  
FEET  
MAX  
O2  
ATR  
Fig. 78 - Log (Nitrogen Data)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
71  
N2  
O2  
ATR  
Fig. 79 - Log (Oxygen Data)  
AFTER THE FIRST 2 HOURS  
N2  
O2  
ATR  
Fig. 80 - Surface Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
72  
N2  
WET CONTACTS  
O2  
ATR  
Fig. 81 - Fly Mode  
(Activation Contacts Wet)  
N2  
O2  
ATR  
Fig. 82 - Desaturation Mode  
(activation contacts wet)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
73  
DOWNLOADING DATA TO A PC  
NOTE: Ensure that the download product that you  
acquire is compatible with the Pro Plus 2 and the  
PC equipment that you will be using.  
N2  
O2  
ATR  
Fig. 83 - PC Interface  
Download from Www.Somanuals.com. All Manuals Search And Download.  
74  
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
SIMULATOR (DEMO) MODE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
75  
N2  
SIMULATOR MODE  
DEMO  
O2  
ATR  
Fig. 84 - Simulator Mode  
Access and Setup (while in real Surface Mode)  
N2  
DEMO  
O2  
ATR  
Fig. 85 - Set Demo Gauge  
Download from Www.Somanuals.com. All Manuals Search And Download.  
76  
N2  
DEMO  
O2  
ATR  
Fig. 86 - Set Demo Calibration  
N2  
DEMO  
O2  
P SI  
ATR  
Fig. 87 - Set Pressure On/Off  
Download from Www.Somanuals.com. All Manuals Search And Download.  
77  
N2  
DEMO  
O2  
ATR  
Fig. 88 - Set Demo FO2  
N2  
DEMO  
Demo Dive Mode  
O2  
P SI  
0
5
1 0  
2 0  
3 0 4 0  
5 0 6 0  
ATR  
Fig. 89 - Demo Dive Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
78  
N2  
Descending  
DEMO  
O2  
P SI  
0
5
1 0  
2 0  
3 0 4 0  
5 0 6 0  
ATR  
Fig. 90 - Dive Mode Setup  
N2  
FEET  
MAX  
DEMO  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 91 - Time Acceleration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
79  
N2  
Ascending  
FEET  
DEMO  
O2  
P SI  
0
5
1 0  
ATR  
Fig. 92 - Ascent set at 1 fps  
N2  
FEET  
TOO  
FAS T  
DEMO  
O2  
P SI  
0
5
1 0  
2 0  
ATR  
Fig. 93 - Ascent set at 3 fps  
Download from Www.Somanuals.com. All Manuals Search And Download.  
80  
Surfacing from a Simulated Dive  
N2  
DEMO  
O2  
P SI  
ATR  
Fig. 94 - Demo Surface Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
82  
WARNING: Prior to diving with the Pro Plus 2, you  
must also read and understand the Oceanic Dive  
Computer Safety and Reference Manual which  
provides Important Warnings and Safety Recom-  
mendations as well as general product information.  
GENERAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
83  
CARE AND CLEANING  
a
INSPECTIONS AND SERVICE  
X
X
X
X
b
Fig. 95 - Case Back  
Download from Www.Somanuals.com. All Manuals Search And Download.  
84  
To Obtain Service:  
E
Download from Www.Somanuals.com. All Manuals Search And Download.  
85  
NOTE: The procedures that follow must be closely adhered to. Damage due  
to improper Battery replacement is not covered by the unit's 2 year warranty.  
BATTERYREPLACEMENT  
Hot Swap  
Download from Www.Somanuals.com. All Manuals Search And Download.  
86  
Battery Removal  
X
X
X
X
a
Fig. 96 - Battery Hatch  
Download from Www.Somanuals.com. All Manuals Search And Download.  
87  
Moisture in the Battery Compartment  
+
a
Fig. 97 - O-ring Installation  
Battery Installation  
+
a
Fig. 98 - Battery Orientation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
88  
Battery Hatch Installation  
Inspection  
X
X
a
c
d
b
X
X
Fig. 99 - Hatch Installation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
89  
SPECIFICATIONS  
CAN BE USED AS  
OPERATIONAL MODES (SURFACE)  
Air Computer  
Nitrox Computer  
Digital Depth Gauge/Timer  
Activation/Diagnostic  
Surface  
Pre Dive Planning Sequence  
(30 to 190 feet / 9 to 57 meters)  
Time to Fly Countdown  
Desaturation Countdown  
Dive Log (Date / Time, Nitrogen, and Oxygen)  
Set Mode 1:  
NO DECOMPRESSION MODEL  
Basis:  
Modified Haldanean Algorithm  
12 tissue compartments  
• FO2 (Air, 21 to 50% O2)  
Data Base:  
Diving Science and Technology (DSAT) - Rogers/  
Powell  
• Max Depth Alarm (30 to 300 FT /9 to 99 M)  
• Elapsed Dive Time Alarm (0:10 to 3:00 hr:min)  
• PC Interface (to Download data)  
Set Mode 2:  
Performance:  
• Units of Measure (Imperial / Metric)  
• Hour Format (12 / 24)  
Tissue compartment halftimes (mins.) Spencer’s “M”  
values  
• Time (Hour, Minute)  
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480  
Reciprocal subsurface elimination  
60 minute surface credit control for compartments  
faster than 60 minutes  
Tissue compartments tracked up to 24 hours after  
last dive  
• Date (Year, Month, Day)  
• Audible Alarm / LED Warning (On/Off)  
• Max TLBG Alarm (1 to 12 segments)  
• Air Time Remaining BG Alarm (0 to 60 minutes)  
• Turn Press Alarm (1000 to 3000 PSI/69 to 205  
BAR)  
• End Press Alarm (300 to 1500 PSI/20 to 104 BAR)  
• Dive Time Remaining Alarm (0:00 - 0:20 min)  
• Max PO2 Alarm (1.20 - 1.60 ATA)  
Decompression Capabilities (stop ceilings):  
10, 20, 30, 40, 50, and 60 FT  
(3, 6, 9, 12, 15, and 18 M)  
FO2 50% Default (On/Off)  
• Backlight Duration (:00 / :03 / :07 seconds)  
• Sampling Rate - memory storage for download  
(2, 15, 30, 60 seconds; 2, 5, 10 FT, .5, 1.5, 3 M)  
• Digital Gauge Mode (On / Off)  
Altitude Algorithm:  
Based on NOAA tables  
Oxygen Exposure Limits:  
• Water Activation (On / Off)  
Based on NOAA tables  
Simulator Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
90  
SPECIFICATIONS (CONTINUED)  
OPERATIONAL MODES (DIVE)  
No Decompression Dive:  
#1 - Current Depth, Dive Time Remaining, Cylinder Pressure, Bar Graphs  
#2 - Current Depth, Dive Time Remaining, Max Depth, Elapsed Dive Time, Cylinder Pressure, Bar Graphs  
#3 - Current Depth, Dive Time Remaining, Temperature, Time of Day, Cylinder Pressure, Bar Graphs  
#4 - if a nitrox dive - Current Depth, Dive Time Remaining, Current PO2, Cylinder Pressure, Bar Graphs  
Secondary - Current Depth, Air Time Remaining, Cylinder Pressure, Bar Graphs  
Safety Stop - Current Depth, Stop Depth (15 FT/5 M), Countdown Timer (3:00 to 0:00 min:sec), Dive Time  
Remaining, Cylinder Pressure, Bar Graphs  
Digital Gauge Mode:  
Default - Current Depth, Max Depth, Time of Day, Elapsed Dive Time, Cylinder Pressure, Bar Graphs  
Secondary - Current Depth, Air Time Remaining, Cylinder Pressure, Bar Graphs  
Decompression Dive:  
#1 - Default - Current Depth, Stop Depth / Time, Total Ascent Time, Cylinder Pressure, Bar Graphs  
#2 - Current Depth, Stop Depth / Time, Total Ascent Time, Max Depth, Elapsed Dive Time, Cylinder Pressure,  
Bar Graphs  
#3 - Current Depth, Temperature, Time of Day, Total Ascent Time, Cylinder Pressure, Bar Graphs  
#4 - if nitrox dive - Current Depth, Current PO2, Total Ascent Time, Cylinder Pressure, Bar Graphs  
Violation - Conditional, Delayed, and Immediate/Gauge  
High PO2 (1.20 to 1.60 ATA)  
High Oxygen Accumulation (300 OTU per dive / 24 hr)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
91  
SPECIFICATIONS (CONTINUED)  
DISPLAY RANGE/RESOLUTION  
Numeric Displays:  
Range:  
Resolution:  
Dive Number  
Depth  
0 to 24  
1
0 to 330 FT (0 to 99.9 M)  
330 FT (99.9 M)  
Air, 21 to 50 %  
0.00 to 5.00 ATA  
0:00 to 9:59 hr:min  
0:00 to 9:59 hr:min  
0:00 to 9:59 hr:min  
Time  
0:00 to 9:59 hr:min  
0:00 - 9:59 hr:min  
0:00 - 23:59 hr:min  
0:00 - 23:59 hr:min  
23:50 - 0:00 hr:min*  
1 FT (.1 M)  
1 FT (.1 M)  
1 %  
.01 ATA  
1 minute  
1 minute  
1 minute  
Maximum Depth  
FO2 Set Point  
PO2 Value  
Dive Time Remaining  
Air Time Remaining  
Total Ascent Time  
Safety  
Stop  
3:00  
to  
0:00  
min:sec1  
Decompression Stop Time  
Elapsed Dive Time  
Surface Time  
Dive Log Surface Interval  
Time to Fly  
1 minute  
1 minute  
1 minute  
1 minute  
1 minute  
(* starting 10 min after the dive)  
23:50 - 0:00 hr:min*  
Time to Desaturate  
1 minute  
(* starting 10 min. after the dive)  
0 to 99°F (-9 to 60°C)  
0 to 5000 PSI (0 to 352 BAR)  
Temperature  
Cylinder Pressure  
1°  
10 PSI (.5 BAR)  
Special Displays:  
Occurrence  
Diagnostic Display  
Out of Range (- - -)  
Gauge Mode Countdown Timer  
After Manual Activation  
>330 FT (>99.9 M)  
23:50 to 0:00 hr:min (after violation)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
92  
SPECIFICATIONS (CONTINUED)  
BAR GRAPHS  
Tissue Loading Bar Graph:  
segments  
Oxygen (O2) Bar Graph:  
segments  
No Decompression zone (green)  
No Deco Caution zone (yellow)  
Decompression Warning zone (red)  
9
2
1
Normal zone (green)  
Caution zone (yellow)  
Danger zone (red)  
4
1
1
Variable Ascent Rate Indicator: 60 feet (18 m) & Shallower  
Deeper than 60 feet (18 m)  
segmentsfeet/min meters/min  
segmentsfeet/min  
meters/min  
0 - 3  
3.5 - 4.5  
5 - 6  
6.5 - 7.5  
8 - 9  
> 9  
0
1
2
3
4
5
0 - 10  
11 - 15  
16 - 20  
21 - 25  
26 - 30  
> 30  
0
1
2
3
4
5
0 - 20  
0 - 6  
Normal Zone (Green)  
Normal Zone (Green)  
Normal Zone (Green)  
Caution Zone (Yellow)  
Too Fast Zone (Red - flashing)  
21 - 30 6.5 - 9  
31 - 40 9.5 - 12  
41 - 50 12.5 - 15  
51 - 60 15.5 - 18  
> 60  
> 18  
OPERATIONAL PERFORMANCE  
Function: Accuracy:  
Depth  
±1% of full scale  
Timers  
1 second per day  
Dive Counter:  
Displays Dives #1 to 24, 0 if no dive made yet  
Resets to Dive #1, upon diving (new activation period)  
Dive Log Mode:  
Stores 24 most recent dives in memory for viewing  
After 24 dives, adds 25th dive in memory and deletes the first dive  
Download from Www.Somanuals.com. All Manuals Search And Download.  
93  
SPECIFICATIONS (CONTINUED)  
OPERATIONAL PERFORMANCE (continued)  
Altitude:  
Operational from sea level to 14,000 feet (4,270 meters) elevation  
Measures ambient pressure every 30 minutes and when manually activated (no when wet contacts are bridged)  
Compensates for Altitude when manually activated (no compensation if activated by immersion in water)  
Compensation begins at 2,000 feet (610 meters) elevation and every 1,000 feet (305 meters) higher  
Power:  
Battery  
• Shelf life  
1 - 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)  
Up to 5 years  
• Replacement  
• Life expectancy  
dive day)  
User replaceable (annual recommended)  
50 dive hours (if 1 - 1 hour dive per dive day) to over 150 dive hours (if 3 - 1 hour dives per  
Battery Indicator:  
segments displayed  
all  
estimated power remaining  
25 to 100%  
1 (inside)  
< 25%  
Activation:  
Manual - push button (recommended)  
Automatic - by immersion in water (as a backup if set ON)  
H2O graphic indicates Wet Contacts are bridged (unit must be dried prior to transport or storage)  
Cannot be manually activated deeper than 4 FT (1.2 M), if the Water Activation feature is set OFF.  
Cannot be activated at elevations higher than 14,000 feet (4,270 meters)  
Shutoff:  
Automatically shuts off if no dive is made within 120 minutes after initial activation. Reactivation required.  
Automatically shuts off 24 hours after last dive (will reactivate if the H2O graphic is displayed).  
Cannot be shut off manually.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
94  
SPECIFICATIONS (CONTINUED)  
OPERATIONAL PERFORMANCE (continued)  
Setting FO2:  
Automatically set for 'Air' upon activation  
Remains set for Air unless an FO2 numerical value is set  
Nitrox set points from 21 to 50 %  
If set for 21%, remains set for 21% until changed  
If set for >21%, it reverts to 50% 10 minutes after the dive, if the FO2 Default is ON. If the FO2 Default is OFF, the  
value will remain at the value set.  
Operating Temperature:  
Out of the water - between 20 °F and 140 °F (-6 and 60 °C)  
In the water - between 28 °F and 95 °F (-2 and 60 °C).  
At extremely low temperatures, the LCD may become sluggish, but this will not affect it's accuracy. If stored or  
transported in extremely low temperature areas (below freezing), you should warm the unit and its battery with  
body heat before diving.  
ACCESSORIES (optional items available from your Authorized Oceanic Dealer):  
• Lens Protector - adheres to lens face, prevents scratches  
• PC download package (hardware and software)  
• Battery Kit - includes 1 Battery, 1 Battery Hatch O-ring, Silicone Grease  
Download from Www.Somanuals.com. All Manuals Search And Download.  
95  
OCEANIC WORLD WIDE  
OCEANIC USA  
2002 Davis Street  
San Leandro, CA 94577  
Tel: 510/562-0500  
Fax: 510/569-5404  
Web site: http://www.OceanicWorldwide.com  
Oceanic Central/North Europe  
Oceanic Diving Australia Pty. Ltd  
Sorrento, Victoria, Australia  
Tel: 61-3-5984-4770 Fax: 61-3-5984-4307  
Wendelstein, Germany  
Tel: 09129-9099780 Fax: 09129-9099789  
Oceanic South Europe  
Genova, Italy  
Oceanic Asia-Pacific Pte. Ltd  
Singapore  
Tel: 0039-010-8382006 Fax: 0039-010-8365360  
Tel: 65-6391-1420 Fax: 65-6297-5424  
Oceanic SW, Ltd  
Devon, United Kingdom  
Oceanic Japan  
Yokohama, Japan  
Tel: 44-1-404-89-1819 Fax: 44-1-404-89-1909  
Tel: 045-575-6671 Fax: 045-575-6673  
Oceanic France  
Marseille, France  
Oceanic International (Pacific)  
Kapolei, Hawaii  
Tel: 0033.491.25.37.78 Fax: 0033.491.72.34.48  
Tel: 808-682-5488 Fax: 808-682-1068  
Download from Www.Somanuals.com. All Manuals Search And Download.  
96  
INSPECTION / SERVICE RECORD  
Serial Number _______________________  
Date of purchase _____________________  
Purchased from ______________________  
Below to be filled in by an Authorized Oceanic Dealer:  
E
Date  
Service Performed  
Dealer / Technician  
Download from Www.Somanuals.com. All Manuals Search And Download.  
97  
NOTES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
98  
RESET FEATURE  
WARNING: Reset after a dive and subsequent use for a repetitive dive con-  
ducted by the same diver could result in serious injury to or death.  
RESET PROCEDURE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Snow Blower 769 03250 User Manual
NEC Car Video System 2190UXp User Manual
NEC Projector MultiSync MT600 User Manual
Nintendo Video Games 45496902971 User Manual
Omnimount TV Mount 10041 User Manual
Omnimount TV Mount OM10324 User Manual
Panasonic Garage Door Opener CZ RTC2 User Manual
Panasonic Switch EVQ11 User Manual
Panasonic TV Mount ETPKE200H User Manual
ParaBody Home Gym 093 User Manual