Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
LIMITED TWO-YEAR WARRANTY ............................................................................................................................ 2
NOTICES ..................................................................................................................................................................... 2
DECOMPRESSION MODEL ....................................................................................................................................... 2
FEATURES AND DISPLAYS............................................................................................. 7
INTERACTIVE CONTROL CONSOLE ....................................................................................................................... 8
BAR GRAPHS ............................................................................................................................................................. 9
Tissue Loading Bar Graph (TLBG)......................................................................................................................... 9
Oxygen Bar Graph (O2BG) .................................................................................................................................. 10
Variable Ascent Rate Indicator (VARI) .................................................................................................................. 10
Air Time Remaining Bar Graph (ATRBG) ............................................................................................................. 11
DIVE TIME REMAINING ........................................................................................................................................... 11
ALPHA / NUMERIC DISPLAYS ................................................................................................................................. 12
Cylinder Pressure ................................................................................................................................................. 12
Depth Displays ...................................................................................................................................................... 12
Time and Date Displays ....................................................................................................................................... 13
Temperature Display ............................................................................................................................................. 13
AUDIBLE ALARM ...................................................................................................................................................... 14
LED Warning Light ............................................................................................................................................... 14
SMARTGLO BACKLIGHT ........................................................................................................................................ 16
POWER SUPPLY ...................................................................................................................................................... 16
Battery Consumption Indicator ............................................................................................................................. 16
Low Battery Condition .......................................................................................................................................... 17
FO2 MODE ................................................................................................................................................................ 18
FO2 50% Default .................................................................................................................................................. 19
Download from Www.Somanuals.com. All Manuals Search And Download.
3
CONTENTS (continued)
ACTIVATIONAND SETUP .............................................................................................. 21
ACTIVATION .............................................................................................................................................................. 22
SURFACE MODE ...................................................................................................................................................... 23
Accessing Other Modes ....................................................................................................................................... 23
SET MODES .............................................................................................................................................................. 24
ENTERING SETTINGS -SET MODE #1 .............................................................................................................. 25
ENTERING SETTINGS -SET MODE #2 .............................................................................................................. 29
PLAN AND DIVE MODES ............................................................................................... 45
TM
PRE DIVE PLANNING SEQUENCE
.................................................................................................................... 46
TISSUE LOADING BAR GRAPH .............................................................................................................................. 48
OXYGEN ACCUMULATION BAR GRAPH ............................................................................................................... 49
VARIABLE ASCENT RATE INDICATOR .................................................................................................................. 49
AIR TIME REMAINING BAR GRAPH BAR GRAPH ................................................................................................ 50
CONTROL OF DISPLAYS ......................................................................................................................................... 50
NO DECOMPRESSION DIVE MODE ....................................................................................................................... 51
DECOMPRESSION DIVE MODE .............................................................................................................................. 54
VIOLATION MODES .................................................................................................................................................. 57
Conditional Violation Mode ................................................................................................................................... 57
Delayed Violation Modes ...................................................................................................................................... 59
Immediate Violation Mode and Gauge Mode ....................................................................................................... 60
HIGH PO2 DIVE MODE ............................................................................................................................................. 62
HIGH OXYGEN ACCUMULATION ............................................................................................................................ 63
USER SET DIGITAL GAUGE MODE ........................................................................................................................ 64
UNEXPECTED LOSS OF DISPLAYED INFORMATION .......................................................................................... 64
Download from Www.Somanuals.com. All Manuals Search And Download.
4
CONTENTS (continued)
POST DIVE MODES ....................................................................................................... 65
POST DIVE SURFACE MODE .................................................................................................................................. 66
TRANSITION PERIOD .............................................................................................................................................. 66
AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS) .................................................................................. 68
To activate the Backlight - .................................................................................................................................... 68
To access the Pre Dive Planning Sequence - ...................................................................................................... 68
To access the Time to Fly Countdown ................................................................................................................. 69
To access the Time to Desaturate Countdown .................................................................................................... 69
Log Mode .............................................................................................................................................................. 70
AFTER THE FIRST 2 HOURS .................................................................................................................................. 72
WET CONTACTS ....................................................................................................................................................... 73
DOWNLOADING DATA TO A PC .............................................................................................................................. 74
SIMULATOR (DEMO) MODE .......................................................................................... 75
GENERAL ....................................................................................................................... 83
CARE AND CLEANING ............................................................................................................................................. 84
INSPECTIONS AND SERVICE ................................................................................................................................. 84
BATTERY REPLACEMENT ...................................................................................................................................... 86
SPECIFICATIONS ..................................................................................................................................................... 90
OCEANIC WORLD WIDE ......................................................................................................................................... 96
SERVICE RECORD ................................................................................................................................................... 97
RESET PROCEDURE ............................................................................................................................................... 99
Pay special attention to items marked
with this Warning symbol.
WARNING: Prior to diving with the Pro Plus 2, you must also read and
understand the Oceanic Dive Computer Safety and Reference Manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Components:
a. Select (right) Button
b. LED Warning Light
m
c. Smartglo Sensing Port
d. Advance (front) Button
e. Air Time Remaining Bar Graph
f. O2 (oxygen) Bar Graph
g. Icon - Descend Arrow
Icon - Decompression Ceiling
Icon - Ascend Arrow
h. Graphic - Maximum Depth
i. Tissue Loading Bar Graph
j. Battery Indicator
n
l
o
DECO
N
M
p
k
j
FEET
MAX
TOO
FAS T
q
DEMO
i
k. Icon - Alarm (Set Mode)
l. Icon - Log Mode
MAX
m. Graphic - Demo Mode
n. Graphic - Depth
h
r
o
Graphic - Ascent Too Fast
g
O2
p. Icon - Time
q. Variable Ascent Rate Indicator
r. Icon - Operating Mode
O2
O2
P SI
BAR
f
0
5
ATR
1 0
2 0
3 0 4 0
5 0 6 0
e
a
d
b
c
PRO PLUS 2
Download from Www.Somanuals.com. All Manuals Search And Download.
6
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
FEATURES and DISPLAYS
Download from Www.Somanuals.com. All Manuals Search And Download.
7
INTRODUCTION
INTERACTIVE CONTROL CONSOLE
DECO
N
M
FEET
MAX
TOO
FAS T
DEMO
MAX
O2
O2
O2
0
P SI
BAR
5
1
0
2
0
3
0
4
0
5
0
6
0
ATR
a
b
Fig. 1 - Interactive Control
Download from Www.Somanuals.com. All Manuals Search And Download.
8
BAR GRAPHS
Tissue Loading Bar Graph (TLBG)
DECO
N2
a
O2
NOTE: Displays associated with oxygen and the
O2 Bar Graph will only appear if FO2 has been set
at a value other than 'Air' (e.g., a numerical value).
ATR
Fig. 2 - TLBG
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Oxygen Accumulation Bar Graph (O2BG)
Variable Ascent Rate Indicator (VARI)
60 feet (18 m) & Shallower
Deeper than 60 feet (18 m)
Segments
Ascent Rate =
Segments
Ascent Rate =
DECO
N2
Displayed
FPM
0-10
11-15 3.5-4.5
16-20 5-6
21-25 6.5-7.5
26-30 8-9
>30
MPM
0 - 3
Displayed
FPM
0-20
21-30 6.5-9
31-40 9.5-12
41-50 12.5-15
51-60 15.5-18
MPM
0 - 6
b
0
1
2
3
4
5
0
1
2
3
4
5
TOO
FAS T
>9
>60
>18
a
Fig. 4 - VARI Values
WARNING: At depths greater than 60 FT (18 M),
ascent rates should not exceed 60 fpm (18 mpm). At
depths of 60 FT (18 M) and shallower, ascent rates
should not exceed 30 fpm (9 mpm).
O2
O2
0
5
1 0
2 0
3 0 4 0
5 0 6 0
ATR
Fig. 3 - O2BG and VARI
Download from Www.Somanuals.com. All Manuals Search And Download.
10
N2
Air Time Remaining Bar Graph (ATRBG)
FEET
b
O2
P SI
a
0
5
ATR
1 0
2 0
Fig. 5 - ATRBG
DIVE TIME REMAINING
Download from Www.Somanuals.com. All Manuals Search And Download.
11
ALPHA / NUMERIC DISPLAYS
Cylinder Pressure Display
Depth Displays
b
N2
FEET
MAX
c
O2
P SI
0
5
1 0
2 0
ATR
a
Fig. 6 - Cylinder Pressure
and Depth Displays
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Time and Date Displays
b
N2
FEET
Temperature Display
c
a
O2
P SI
0
5
1 0
2 0
ATR
Fig. 7 - Time and Temperature
Displays
Download from Www.Somanuals.com. All Manuals Search And Download.
13
NOTE: Each numeric and graphic display represents a unique piece of
information. It is imperative that you understand the formats, ranges, and
values of the information represented to avoid any possible misunderstand-
ing that could result in error. The Informational Displays are described in
detail as the various operating modes they appear in are presented through-
out this manual.
AUDIBLEALARM
LED Warning Light
A single short beep (which cannot be disabled) is emitted for the following -
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Situations that will sound the Alarm, if it is turned ON (a user setting), include -
During the following situations, the 10 second continuous tone will be followed by
a 5 second steady beep that will not turn off when acknowledged, even if it was
user Set OFF -
Download from Www.Somanuals.com. All Manuals Search And Download.
15
SMARTGLO® BACKLIGHT
NOTE: Extensive use of the Backlight reduces
estimated Battery life. Also, the Backlight does not
operate during a Low Battery Condition or when
downloading data to a PC.
a
POWER SUPPLY
N2
Battery Indicator
O2
ATR
Fig. 8 - Battery Indicator
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Low Battery Condition
N2
O2
P SI
ATR
Fig. 9 - Low Battery Condition
Download from Www.Somanuals.com. All Manuals Search And Download.
17
FO2 MODE
N2
O2
ATR
Fig. 10 - FO2 set for AIR
Download from Www.Somanuals.com. All Manuals Search And Download.
18
N2
MAX
O2
ATR
Fig. 11 - FO2 set for 21%
FO2 50% Default
N2
O2
ATR
Fig. 12 - FO2 Default ON
Download from Www.Somanuals.com. All Manuals Search And Download.
19
WARNING: When the unit shuts off, the FO2 set
point will default to AIR regardless if the 50%
Default is set ON or OFF. Always set, or verify, the
FO2 set point prior to each nitrox dive.
Setting FO2 for a nitrox dive is described on page
25.
N2
O2
ATR
Fig. 13 - FO2 Default OFF
Download from Www.Somanuals.com. All Manuals Search And Download.
20
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
ACTIVATION and SETUP
Download from Www.Somanuals.com. All Manuals Search And Download.
21
ACTIVATION
Backup Activation (only if Water Activation is set ON)
DECO
N2
M
FEET
MAX
TOO
FAS T
DEMO
MAX
WARNING: If the unit is manually activated at eleva-
tions higher than 14,000 feet (4,267 meters), it will
perform a diagnostic check followed by immediate
shutdown.
O2
O2
O2
P SI
BAR
0
5
1 0
2 0
3 0 4 0
5 0 6 0
ATR
Fig. 14 - Diagnostic Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
22
SURFACE MODE
N2
NOTE: If the wet contacts are bridged, the graphic
O2
P SI
'H2O' will appear in place of the dive number '0'
(Fig. 16). After the unit is rinsed and dried, '0' will
replace 'H2O'.
ATR
Fig. 15 - Surface Mode
N2
Accessing Other Modes
O2
P SI
ATR
Fig. 16 - Surface Mode
(rinse and dry the unit)
Download from Www.Somanuals.com. All Manuals Search And Download.
23
SET MODES
N2
O2
ATR
Fig. 17 - Set Mode 1
N2
O2
ATR
Fig. 18 - Set Mode 2
Download from Www.Somanuals.com. All Manuals Search And Download.
24
N2
ENTERING SETTINGS -SET MODE #1
O2
ATR
Fig. 19 - Set FO2
N2
MAX
a
O2
ATR
Fig. 20 - FO2 set for 32%
Download from Www.Somanuals.com. All Manuals Search And Download.
25
N2
FEET
MAX
O2
ATR
Fig. 21 - Set Max Depth Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
26
N2
O2
ATR
Fig. 22 - Set Elapsed Dive
Time Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
27
NOTE: For more
information
regarding PC
Interface, refer
to page 74 of
this manual and
to documents
provided with
the PC down-
load product.
N2
O2
ATR
Fig. 23 - PC Interface
Download from Www.Somanuals.com. All Manuals Search And Download.
28
ENTERING SETTINGS -SET MODE #2
N2
O2
ATR
Fig. 24 - Set Units of Measure
Download from Www.Somanuals.com. All Manuals Search And Download.
29
N2
O2
ATR
Fig. 25 - Set Hour Format
Download from Www.Somanuals.com. All Manuals Search And Download.
30
N2
O2
ATR
Fig. 26 - Set Hour
N2
O2
ATR
Fig. 27 - Set Minute
Download from Www.Somanuals.com. All Manuals Search And Download.
31
N2
Fig. 28 - Set Year
N2
Fig. 29 - Set Month
N2
Fig. 30 - Set Day
Download from Www.Somanuals.com. All Manuals Search And Download.
32
N2
O2
ATR
Fig. 31- Set Audible Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
33
DECO
N2
O2
ATR
Fig. 32 - Set Max TLBG Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
34
N2
O2
0
5
1 0
2 0
3 0 4 0
5 0 6 0
ATR
Fig. 33 - Set Air Time Remaining
Bar Graph Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
35
N2
O2
P SI
ATR
Fig. 34 - Set Turn Pressure Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
36
N2
O2
P SI
ATR
Fig. 35 - Set End Pressure Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
37
N2
O2
ATR
Fig. 36 - Set Dive Time
Remaining Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
38
N2
MAX
O2
ATR
Fig. 37 - Maximum PO2 Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
39
N2
O2
ATR
Fig. 38 - Set FO2 50% Default
Download from Www.Somanuals.com. All Manuals Search And Download.
40
N2
O2
ATR
Fig. 39 - Set Backlight Duration
Download from Www.Somanuals.com. All Manuals Search And Download.
41
NOTE: Sampling
Rate is the interval
at which data
samples are
recorded during a
dive for subse-
quent download to
the PC program.
This setting has
no effect on
displayed data or
data in the unit's
viewable Log.
N2
O2
ATR
Fig. 40 - Set PC Sampling Rate
Download from Www.Somanuals.com. All Manuals Search And Download.
42
NOTE: Once a dive
is made with this
feature set ON, the
setting will be
locked ON for 24
hours after the dive.
Set Digital Gauge
Mode will not
appear as a selec-
tion during that 24
hour period.
N2
O2
ATR
Fig. 41 - Set Digital Gauge Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
43
WARNING: If this
feature is set for
OFF, the Pro Plus 2
must be manually
activated prior to
commencing a dive.
N2
O2
ATR
Fig. 42 - Set Water Activation
Download from Www.Somanuals.com. All Manuals Search And Download.
44
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
PLAN and DIVE MODES
Download from Www.Somanuals.com. All Manuals Search And Download.
45
PRE DIVE PLANNING SEQUENCETM
Depth
NDL
feet (meters)
hours:mins
30 (9)
4:20 (4:43)
2:17 (2:24)
1:21 (1:25)
40 (12)
50 (15)
60 (18)
70 (21)
80 (24)
90 (27)
100 (30)
110 (33)
120 (36)
130 (39)
140 (42)
150 (45)
160 (48)
170 (51)
180 (54)
190 (57)
:57
:40
:30
:24
:19
:16
:13
:11
:09
:08
:07
:07
:06
:05
(:59)
(:41)
(:32)
(:25)
(:20)
(:17)
(:14)
(:11)
(:09)
(:08)
(:07)
(:06)
(:06)
(:05)
No Decompression Limits
for an Air Dive
(no dive made yet)
Download from Www.Somanuals.com. All Manuals Search And Download.
46
N2
FEET
MAX
O2
ATR
Fig. 43 - Nitrogen Control
N2
FEET
MAX
O2
O2
ATR
Fig. 44 - Oxygen Control
Download from Www.Somanuals.com. All Manuals Search And Download.
47
NOTE: The Pro Plus 2 will store oxygen accumula-
tion calculations for up to 10 dives conducted
during a 24 hour period. If the maximum limit for
oxygen loading has been exceeded for that day (24
hour period), all of the segments of the O2 bar
graph will be displayed flashing .
Depth/Time values will not appear until the O2 bar
graph recedes into the green (normal) zone (i.e.,
your daily oxygen dosage decreases an amount
equivalent to the amount accumulated during the
latest dive completed).
a
TISSUE LOADING BAR GRAPH (Fig. 45a)
N2
FEET
O2
P SI
0
5
1 0
2 0
ATR
Fig. 45 - Tissue Loading Bar
Graph
Download from Www.Somanuals.com. All Manuals Search And Download.
48
N2
OXYGEN ACCUMULATION BAR GRAPH (Fig. 46a)
FEET
a
b
VARIABLE ASCENT RATE INDICATOR (Fig. 46b)
O2
P SI
0
5
1 0
2 0
ATR
Fig. 46 - O2 Bar Graph & VARI
N2
FEET
TOO
FAS T
O2
P SI
NOTE: Refer to page 10 for additional information
pertaining to the Variable Ascent Rate Indicator.
0
5
ATR
1 0
2 0
3 0
Fig. 47 - Ascent Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
49
AIR TIME REMAINING BAR GRAPH
N2
FEET
O2
P SI
0
5
1 0
2 0
ATR
a
Fig. 48 - Air Time Remaining
Bar Graph
CONTROL OF DISPLAYS
Download from Www.Somanuals.com. All Manuals Search And Download.
50
NO DECOMPRESSION DIVE MODE
No Deco
Mode icon
N2
FEET
No Deco Dive Mode - Display #1 (Fig. 49)
O2
P SI
0
5
1 0
2 0
ATR
Fig. 49 - No Deco #1
Download from Www.Somanuals.com. All Manuals Search And Download.
51
N2
No Deco Dive Mode - Display #2 (Fig. 50)
FEET
MAX
O2
P SI
No Deco Dive Mode - Display #3 (Fig. 51)
0
5
ATR
1 0
2 0
Fig. 50 - No Deco #2
N2
FEET
(lower portion same as Fig. 50)
Fig. 51 - No Deco #3
No Deco Dive Mode - Display #4 (Fig. 52)
N2
FEET
(lower portion same as Fig. 50)
Fig. 52 - No Deco #4
Download from Www.Somanuals.com. All Manuals Search And Download.
52
N2
No Deco Dive Mode - Secondary Display (Fig. 53)
FEET
O2
P SI
0
5
1 0
2 0
ATR
No Deco Dive Mode - SAFETY STOP (Fig. 54)
Fig. 53 - No Deco Secondary
N2
FEET
O2
P SI
0
5
1 0
2 0
3 0
ATR
Fig. 54 - No Deco Safety Stop
Download from Www.Somanuals.com. All Manuals Search And Download.
53
DECOMPRESSION DIVE MODE
Deco Mode icon
DECO
N2
FEET
Total Ascent Time
a
O2
P SI
0
5
1 0
ATR
Fig. 55 - Entry into Deco Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
54
Managing Decompression Stops
c
DECO
N2
FEET
b
Decompression Dive Mode - Main Display #1 (Fig. 56)
a
O2
P SI
0
5
1 0
2 0
ATR
Fig. 56 - Deco #1
Download from Www.Somanuals.com. All Manuals Search And Download.
55
DECO
N2
Decompression Dive Mode - Display #2 (Fig. 57)
Decompression Dive Mode - Display #3 (Fig. 58)
Decompression Dive Mode - Display #4 (Fig. 59)
FEET
MAX
O2
P SI
0
5
1 0
2 0
ATR
Fig. 57 - Deco #2
DECO
N2
FEET
(lower portion same as Fig. 57)
Fig. 58 - Deco #3
DECO
N2
FEET
(lower portion same as Fig. 57)
Fig. 59 - Deco #4
Download from Www.Somanuals.com. All Manuals Search And Download.
56
VIOLATION MODES
Conditional Violation Mode (Fig. 60)
a
DECO
N2
FEET
b
O2
P SI
0
5
1 0
2 0
ATR
Fig. 60 - Conditional Violation
Download from Www.Somanuals.com. All Manuals Search And Download.
57
NOTE: Upon entry into the following 3 Delayed
Violation Modes, the red LED warning light will
light and the Audible Alarm will sound, even if Set
OFF. The Alarm cannot be acknowledged (si-
lenced) by pressing the Left (Advance) button.
Delayed Violation Mode #1 (Fig. 61)
DECO
N2
FEET
O2
P SI
0
5
1 0
2 0
ATR
Fig. 61 - Delayed Violation #1
Download from Www.Somanuals.com. All Manuals Search And Download.
58
DECO
N2
Delayed Violation Mode #2 (Fig. 62)
FEET
O2
P SI
0
5
1 0
2 0
3 0 4 0
5 0
ATR
Fig. 62 - Delayed Violation #2
N2
FEET
Delayed Violation Mode #3 (Fig. 63)
MAX
O2
P SI
0
5
1 0
2 0
ATR
Fig. 63 - Delayed Violation #3
Download from Www.Somanuals.com. All Manuals Search And Download.
59
Immediate Violation Mode and Gauge Mode
DECO
N2
FEET
MAX
O2
O2
P SI
0
5
1 0
ATR
Fig. 64 - Immediate Violation
Gauge Mode (underwater)
Download from Www.Somanuals.com. All Manuals Search And Download.
60
DECO
N2
O2
Responsible
O2
P SI
ATR
Fig. 65 - Immediate Violation
Gauge Mode (after surfacing)
Download from Www.Somanuals.com. All Manuals Search And Download.
61
N2
HIGH PO2 DIVE MODE
FEET
O2
O2
0
P SI
5
1 0
2 0
3 0
ATR
Fig. 66 - PO2 Warning
N2
FEET
O2
O2
0
P SI
5
1 0
2 0
3 0
ATR
Fig. 67 - PO2 Alarm
Download from Www.Somanuals.com. All Manuals Search And Download.
62
HIGH OXYGEN ACCUMULATION
N2
FEET
O2
O2
O2
0
P SI
5
1 0
ATR
Fig. 68 - High O2
Download from Www.Somanuals.com. All Manuals Search And Download.
63
N2
USER SET DIGITAL GAUGE MODE
FEET
MAX
O2
P SI
0
5
1 0
ATR
Fig. 69 - User Set Gauge Mode
UNEXPECTED LOSS OF DISPLAYED INFORMATION
N2
FEET
MAX
O2
P SI
0
5
1 0
ATR
Fig. 70 - User Set Gauge Mode
(Air Time Remaining)
Download from Www.Somanuals.com. All Manuals Search And Download.
64
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
POST DIVE MODES
Download from Www.Somanuals.com. All Manuals Search And Download.
65
POST DIVE SURFACE MODE
TRANSITION PERIOD
N2
O2
P SI
ATR
Fig. 71 - Transition Period
Download from Www.Somanuals.com. All Manuals Search And Download.
66
To view that dive's Log (Fig. 72) -
N2
O2
ATR
Fig. 72 - Log Mode
(during Transition Period)
Download from Www.Somanuals.com. All Manuals Search And Download.
67
N2
AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS)
To activate the Backlight -
O2
ATR
To access the Pre Dive Planning Sequence -
Fig. 73 - Surface Mode (>10 min)
N2
FEET
O2
ATR
Fig. 74 - Adjusted NDLs
Download from Www.Somanuals.com. All Manuals Search And Download.
68
N2
To access the Time to Fly Countdown (while in Surface
Mode)
O2
ATR
Fig. 75 - Time to Fly
To access the Time to Desaturation Countdown
(while in Surface Mode)
N2
O2
ATR
Fig. 76 - Time to Desaturate
Download from Www.Somanuals.com. All Manuals Search And Download.
69
LOG MODE
Download from Www.Somanuals.com. All Manuals Search And Download.
70
N2
O2
ATR
Fig. 77 - Log (Date / Time)
N2
FEET
MAX
O2
ATR
Fig. 78 - Log (Nitrogen Data)
Download from Www.Somanuals.com. All Manuals Search And Download.
71
N2
O2
ATR
Fig. 79 - Log (Oxygen Data)
AFTER THE FIRST 2 HOURS
N2
O2
ATR
Fig. 80 - Surface Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
72
N2
WET CONTACTS
O2
ATR
Fig. 81 - Fly Mode
(Activation Contacts Wet)
N2
O2
ATR
Fig. 82 - Desaturation Mode
(activation contacts wet)
Download from Www.Somanuals.com. All Manuals Search And Download.
73
DOWNLOADING DATA TO A PC
NOTE: Ensure that the download product that you
acquire is compatible with the Pro Plus 2 and the
PC equipment that you will be using.
N2
O2
ATR
Fig. 83 - PC Interface
Download from Www.Somanuals.com. All Manuals Search And Download.
74
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
SIMULATOR (DEMO) MODE
Download from Www.Somanuals.com. All Manuals Search And Download.
75
N2
SIMULATOR MODE
DEMO
O2
ATR
Fig. 84 - Simulator Mode
Access and Setup (while in real Surface Mode)
N2
DEMO
O2
ATR
Fig. 85 - Set Demo Gauge
Download from Www.Somanuals.com. All Manuals Search And Download.
76
N2
DEMO
O2
ATR
Fig. 86 - Set Demo Calibration
N2
DEMO
O2
P SI
ATR
Fig. 87 - Set Pressure On/Off
Download from Www.Somanuals.com. All Manuals Search And Download.
77
N2
DEMO
O2
ATR
Fig. 88 - Set Demo FO2
N2
DEMO
Demo Dive Mode
O2
P SI
0
5
1 0
2 0
3 0 4 0
5 0 6 0
ATR
Fig. 89 - Demo Dive Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
78
N2
Descending
DEMO
O2
P SI
0
5
1 0
2 0
3 0 4 0
5 0 6 0
ATR
Fig. 90 - Dive Mode Setup
N2
FEET
MAX
DEMO
O2
P SI
0
5
1 0
2 0
ATR
Fig. 91 - Time Acceleration
Download from Www.Somanuals.com. All Manuals Search And Download.
79
N2
Ascending
FEET
DEMO
O2
P SI
0
5
1 0
ATR
Fig. 92 - Ascent set at 1 fps
N2
FEET
TOO
FAS T
DEMO
O2
P SI
0
5
1 0
2 0
ATR
Fig. 93 - Ascent set at 3 fps
Download from Www.Somanuals.com. All Manuals Search And Download.
80
Surfacing from a Simulated Dive
N2
DEMO
O2
P SI
ATR
Fig. 94 - Demo Surface Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
81
Download from Www.Somanuals.com. All Manuals Search And Download.
82
WARNING: Prior to diving with the Pro Plus 2, you
must also read and understand the Oceanic Dive
Computer Safety and Reference Manual which
provides Important Warnings and Safety Recom-
mendations as well as general product information.
GENERAL
Download from Www.Somanuals.com. All Manuals Search And Download.
83
CARE AND CLEANING
a
INSPECTIONS AND SERVICE
X
X
X
X
b
Fig. 95 - Case Back
Download from Www.Somanuals.com. All Manuals Search And Download.
84
To Obtain Service:
E
Download from Www.Somanuals.com. All Manuals Search And Download.
85
NOTE: The procedures that follow must be closely adhered to. Damage due
to improper Battery replacement is not covered by the unit's 2 year warranty.
BATTERYREPLACEMENT
Hot Swap
Download from Www.Somanuals.com. All Manuals Search And Download.
86
Battery Removal
X
X
X
X
a
Fig. 96 - Battery Hatch
Download from Www.Somanuals.com. All Manuals Search And Download.
87
Moisture in the Battery Compartment
+
a
Fig. 97 - O-ring Installation
Battery Installation
+
a
Fig. 98 - Battery Orientation
Download from Www.Somanuals.com. All Manuals Search And Download.
88
Battery Hatch Installation
Inspection
X
X
a
c
d
b
X
X
Fig. 99 - Hatch Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
89
SPECIFICATIONS
CAN BE USED AS
OPERATIONAL MODES (SURFACE)
Air Computer
Nitrox Computer
Digital Depth Gauge/Timer
Activation/Diagnostic
Surface
Pre Dive Planning Sequence
(30 to 190 feet / 9 to 57 meters)
Time to Fly Countdown
Desaturation Countdown
Dive Log (Date / Time, Nitrogen, and Oxygen)
Set Mode 1:
NO DECOMPRESSION MODEL
Basis:
Modified Haldanean Algorithm
12 tissue compartments
FO2 (Air, 21 to 50% O2)
Data Base:
Diving Science and Technology (DSAT) - Rogers/
Powell
Max Depth Alarm (30 to 300 FT /9 to 99 M)
Elapsed Dive Time Alarm (0:10 to 3:00 hr:min)
PC Interface (to Download data)
Set Mode 2:
Performance:
Units of Measure (Imperial / Metric)
Hour Format (12 / 24)
Tissue compartment halftimes (mins.) Spencers M
values
Time (Hour, Minute)
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
Reciprocal subsurface elimination
60 minute surface credit control for compartments
faster than 60 minutes
Tissue compartments tracked up to 24 hours after
last dive
Date (Year, Month, Day)
Audible Alarm / LED Warning (On/Off)
Max TLBG Alarm (1 to 12 segments)
Air Time Remaining BG Alarm (0 to 60 minutes)
Turn Press Alarm (1000 to 3000 PSI/69 to 205
BAR)
End Press Alarm (300 to 1500 PSI/20 to 104 BAR)
Dive Time Remaining Alarm (0:00 - 0:20 min)
Max PO2 Alarm (1.20 - 1.60 ATA)
Decompression Capabilities (stop ceilings):
10, 20, 30, 40, 50, and 60 FT
(3, 6, 9, 12, 15, and 18 M)
FO2 50% Default (On/Off)
Backlight Duration (:00 / :03 / :07 seconds)
Sampling Rate - memory storage for download
(2, 15, 30, 60 seconds; 2, 5, 10 FT, .5, 1.5, 3 M)
Digital Gauge Mode (On / Off)
Altitude Algorithm:
Based on NOAA tables
Oxygen Exposure Limits:
Water Activation (On / Off)
Based on NOAA tables
Simulator Mode
Download from Www.Somanuals.com. All Manuals Search And Download.
90
SPECIFICATIONS (CONTINUED)
OPERATIONAL MODES (DIVE)
No Decompression Dive:
#1 - Current Depth, Dive Time Remaining, Cylinder Pressure, Bar Graphs
#2 - Current Depth, Dive Time Remaining, Max Depth, Elapsed Dive Time, Cylinder Pressure, Bar Graphs
#3 - Current Depth, Dive Time Remaining, Temperature, Time of Day, Cylinder Pressure, Bar Graphs
#4 - if a nitrox dive - Current Depth, Dive Time Remaining, Current PO2, Cylinder Pressure, Bar Graphs
Secondary - Current Depth, Air Time Remaining, Cylinder Pressure, Bar Graphs
Safety Stop - Current Depth, Stop Depth (15 FT/5 M), Countdown Timer (3:00 to 0:00 min:sec), Dive Time
Remaining, Cylinder Pressure, Bar Graphs
Digital Gauge Mode:
Default - Current Depth, Max Depth, Time of Day, Elapsed Dive Time, Cylinder Pressure, Bar Graphs
Secondary - Current Depth, Air Time Remaining, Cylinder Pressure, Bar Graphs
Decompression Dive:
#1 - Default - Current Depth, Stop Depth / Time, Total Ascent Time, Cylinder Pressure, Bar Graphs
#2 - Current Depth, Stop Depth / Time, Total Ascent Time, Max Depth, Elapsed Dive Time, Cylinder Pressure,
Bar Graphs
#3 - Current Depth, Temperature, Time of Day, Total Ascent Time, Cylinder Pressure, Bar Graphs
#4 - if nitrox dive - Current Depth, Current PO2, Total Ascent Time, Cylinder Pressure, Bar Graphs
Violation - Conditional, Delayed, and Immediate/Gauge
High PO2 (1.20 to 1.60 ATA)
High Oxygen Accumulation (300 OTU per dive / 24 hr)
Download from Www.Somanuals.com. All Manuals Search And Download.
91
SPECIFICATIONS (CONTINUED)
DISPLAY RANGE/RESOLUTION
Numeric Displays:
Range:
Resolution:
Dive Number
Depth
0 to 24
1
0 to 330 FT (0 to 99.9 M)
330 FT (99.9 M)
Air, 21 to 50 %
0.00 to 5.00 ATA
0:00 to 9:59 hr:min
0:00 to 9:59 hr:min
0:00 to 9:59 hr:min
Time
0:00 to 9:59 hr:min
0:00 - 9:59 hr:min
0:00 - 23:59 hr:min
0:00 - 23:59 hr:min
23:50 - 0:00 hr:min*
1 FT (.1 M)
1 FT (.1 M)
1 %
.01 ATA
1 minute
1 minute
1 minute
Maximum Depth
FO2 Set Point
PO2 Value
Dive Time Remaining
Air Time Remaining
Total Ascent Time
Safety
Stop
3:00
to
0:00
min:sec1
Decompression Stop Time
Elapsed Dive Time
Surface Time
Dive Log Surface Interval
Time to Fly
1 minute
1 minute
1 minute
1 minute
1 minute
(* starting 10 min after the dive)
23:50 - 0:00 hr:min*
Time to Desaturate
1 minute
(* starting 10 min. after the dive)
0 to 99°F (-9 to 60°C)
0 to 5000 PSI (0 to 352 BAR)
Temperature
Cylinder Pressure
1°
10 PSI (.5 BAR)
Special Displays:
Occurrence
Diagnostic Display
Out of Range (- - -)
Gauge Mode Countdown Timer
After Manual Activation
>330 FT (>99.9 M)
23:50 to 0:00 hr:min (after violation)
Download from Www.Somanuals.com. All Manuals Search And Download.
92
SPECIFICATIONS (CONTINUED)
BAR GRAPHS
Tissue Loading Bar Graph:
segments
Oxygen (O2) Bar Graph:
segments
No Decompression zone (green)
No Deco Caution zone (yellow)
Decompression Warning zone (red)
9
2
1
Normal zone (green)
Caution zone (yellow)
Danger zone (red)
4
1
1
Variable Ascent Rate Indicator: 60 feet (18 m) & Shallower
Deeper than 60 feet (18 m)
segmentsfeet/min meters/min
segmentsfeet/min
meters/min
0 - 3
3.5 - 4.5
5 - 6
6.5 - 7.5
8 - 9
> 9
0
1
2
3
4
5
0 - 10
11 - 15
16 - 20
21 - 25
26 - 30
> 30
0
1
2
3
4
5
0 - 20
0 - 6
Normal Zone (Green)
Normal Zone (Green)
Normal Zone (Green)
Caution Zone (Yellow)
Too Fast Zone (Red - flashing)
21 - 30 6.5 - 9
31 - 40 9.5 - 12
41 - 50 12.5 - 15
51 - 60 15.5 - 18
> 60
> 18
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth
±1% of full scale
Timers
1 second per day
Dive Counter:
Displays Dives #1 to 24, 0 if no dive made yet
Resets to Dive #1, upon diving (new activation period)
Dive Log Mode:
Stores 24 most recent dives in memory for viewing
After 24 dives, adds 25th dive in memory and deletes the first dive
Download from Www.Somanuals.com. All Manuals Search And Download.
93
SPECIFICATIONS (CONTINUED)
OPERATIONAL PERFORMANCE (continued)
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation
Measures ambient pressure every 30 minutes and when manually activated (no when wet contacts are bridged)
Compensates for Altitude when manually activated (no compensation if activated by immersion in water)
Compensation begins at 2,000 feet (610 meters) elevation and every 1,000 feet (305 meters) higher
Power:
Battery
Shelf life
1 - 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
Up to 5 years
Replacement
Life expectancy
dive day)
User replaceable (annual recommended)
50 dive hours (if 1 - 1 hour dive per dive day) to over 150 dive hours (if 3 - 1 hour dives per
Battery Indicator:
segments displayed
all
estimated power remaining
25 to 100%
1 (inside)
< 25%
Activation:
Manual - push button (recommended)
Automatic - by immersion in water (as a backup if set ON)
H2O graphic indicates Wet Contacts are bridged (unit must be dried prior to transport or storage)
Cannot be manually activated deeper than 4 FT (1.2 M), if the Water Activation feature is set OFF.
Cannot be activated at elevations higher than 14,000 feet (4,270 meters)
Shutoff:
Automatically shuts off if no dive is made within 120 minutes after initial activation. Reactivation required.
Automatically shuts off 24 hours after last dive (will reactivate if the H2O graphic is displayed).
Cannot be shut off manually.
Download from Www.Somanuals.com. All Manuals Search And Download.
94
SPECIFICATIONS (CONTINUED)
OPERATIONAL PERFORMANCE (continued)
Setting FO2:
Automatically set for 'Air' upon activation
Remains set for Air unless an FO2 numerical value is set
Nitrox set points from 21 to 50 %
If set for 21%, remains set for 21% until changed
If set for >21%, it reverts to 50% 10 minutes after the dive, if the FO2 Default is ON. If the FO2 Default is OFF, the
value will remain at the value set.
Operating Temperature:
Out of the water - between 20 °F and 140 °F (-6 and 60 °C)
In the water - between 28 °F and 95 °F (-2 and 60 °C).
At extremely low temperatures, the LCD may become sluggish, but this will not affect it's accuracy. If stored or
transported in extremely low temperature areas (below freezing), you should warm the unit and its battery with
body heat before diving.
ACCESSORIES (optional items available from your Authorized Oceanic Dealer):
Lens Protector - adheres to lens face, prevents scratches
PC download package (hardware and software)
Battery Kit - includes 1 Battery, 1 Battery Hatch O-ring, Silicone Grease
Download from Www.Somanuals.com. All Manuals Search And Download.
95
OCEANIC WORLD WIDE
OCEANIC USA
2002 Davis Street
San Leandro, CA 94577
Tel: 510/562-0500
Fax: 510/569-5404
Web site: http://www.OceanicWorldwide.com
Oceanic Central/North Europe
Oceanic Diving Australia Pty. Ltd
Sorrento, Victoria, Australia
Tel: 61-3-5984-4770 Fax: 61-3-5984-4307
E-mail: [email protected]
Wendelstein, Germany
Tel: 09129-9099780 Fax: 09129-9099789
E-mail: [email protected]
Oceanic South Europe
Genova, Italy
Oceanic Asia-Pacific Pte. Ltd
Singapore
Tel: 0039-010-8382006 Fax: 0039-010-8365360
E-mail: [email protected]
Tel: 65-6391-1420 Fax: 65-6297-5424
E-mail: [email protected]
Oceanic SW, Ltd
Devon, United Kingdom
Oceanic Japan
Yokohama, Japan
Tel: 44-1-404-89-1819 Fax: 44-1-404-89-1909
E-mail: [email protected]
Tel: 045-575-6671 Fax: 045-575-6673
E-mail: [email protected]
Oceanic France
Marseille, France
Oceanic International (Pacific)
Kapolei, Hawaii
Tel: 0033.491.25.37.78 Fax: 0033.491.72.34.48
E-mail: [email protected]
Tel: 808-682-5488 Fax: 808-682-1068
E-mail: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
96
INSPECTION / SERVICE RECORD
Serial Number _______________________
Date of purchase _____________________
Purchased from ______________________
Below to be filled in by an Authorized Oceanic Dealer:
E
Date
Service Performed
Dealer / Technician
Download from Www.Somanuals.com. All Manuals Search And Download.
97
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
98
RESET FEATURE
WARNING: Reset after a dive and subsequent use for a repetitive dive con-
ducted by the same diver could result in serious injury to or death.
RESET PROCEDURE
Download from Www.Somanuals.com. All Manuals Search And Download.
99