Architectural & Engineering Specifications
August 2005
DESCRIPTION
Infinite speed fan control
Polymeric blade and light lens (accepts up to 75W bulb)
Washable aluminum filter
Converts to non-ducted by removing cover plate from control
panel and installing the non-ducted filter (purchase separately)
Mitered sides and hemmed bottom for safety and good looks
Damper/duct connector included
•
•
•
•
4-Way Convertible
Range Hood
•
•
•
•
SM6500 SERIES
7" round plate included
Contemporary styling in White, Black, Almond and
Stainless Steel (with black trim). Also available in White (with
white trim) and Biscuit (with biscuit trim).
Available in 30", 36" and 42" widths
•
INSTALLATION
Complete installation instructions are included with each Range
Hood.
ARCHITECT’S SPECIFICATION
• Range hood shall be NuTone Model SM6500.
SPECIFICATIONS
VOLTS
AMPS
CFM
190
190
220
-
SONES
7.5
DUCT
• Unit shall be convertible between ducted (using a washable
aluminum filter) and non-ducted (using a non-ducted filter -
purchase separately).
120
2.5
3¼" X 10" (H)
3¼" X 10" (V)
7" Round (V)
Non-Ducted
120
2.5
7.5
120
2.5
7.5
• Motor to be permanently lubricated. RPM not to exceed 3250.
120
2.5
-
• Unit shall have infinite speed fan control with separate light/night
light switch.
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed by
the Home Ventilating Institute, for off-the-shelf
products,astheyareavailabletoconsumers.Product
performanceisratedat0.1in. staticpressure, based
on tests conducted in AMCA’s state-of-the-art test
laboratory. Sones are a measure of humanly-
perceived loudness, based on laboratory
measurements.
• Sides shall be mitered and bottom edge hemmed - with no sharp
edges.
• Air delivery shall be no less than 190 CFM (3¼ x 10 discharge)
and 220 CFM (7" round discharge) and sound levels no greater
than 7.5 Sones. All air and sound ratings shall be certified by HVI.
Unit shall be U.L. listed.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
50H
99043308B