Architectural & Engineering Specifications
February 2006
DESCRIPTION
QTXEN Series
BLOWER:
•
•
•
Plug-in, permanently lubricated motor - engineered for
continuous operation
Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
Maintains a high percentage of rated CFM in less than ideal
installations
Fan/Light/Night Lights
MODELS QTXEN080FL,
•
•
Low RPM for quiet operation
Resilient anti-vibration motor mounts
QTXEN110FL, QTXEN150FL
HOUSING:
•
•
•
Rugged, 26 gauge, galvanized steel construction
6” round ducting for superior performance
Polymeric duct connector with tapered sleeve and no metallic
clatter
•
•
•
7-5/8” height allows for 2” x 8” (nominal) joist installations
Sturdy, easy, four-point mounting directly to joist
Includes unique spacer (patent pending) for mounting to
engineered “I” joists
•
Can be mounted in ceilings up to 12/12 pitch
GRILLE:
•
•
Polymeric construction
Innovative design - the result of extensive research with
designers and consumers
26W fluorescent lamp * (bulb included) and 4W night light
(bulb not included)
Durable steel reflector with white enamel finish
•
•
CONTROLS (Purchase separately):
•
Refer to NuTone’s catalog for a complete line of accessories
to effectively adapt these fans to your construction
requirements.
ARCHITECT’S SPECIFICATION
• Ceiling Ventilator shall be NuTone Model QTXEN080FL
(QTXEN110FL) (QTXEN150FL).
• Ceiling Ventilator shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be ducted to
a roof or wall cap using 6” round ductwork.
• Blower assembly shall be removable, have a centrifugal-type
blower wheel and a permanently lubricated motor designed for
continuous operation and mounted with resilient anti-vibration
mounts.
U.L. Listed for use over bathtubs and showers when connected
to a GFCI protected branch circuit (ceiling mount only).
U.L. Listed for use in insulated ceilings (TYPE I.C.)
3-Year Warranty
• Non-metallic damper/duct connector shall be included.
• Lamp shall be 26W fluorescent * with separate 4W night light.
• Air delivery shall be no less than 80 (110) (150) CFM and sound
level no greater than 0.3 (0.9) (1.4) Sones. All air and sound
ratings shall be certified by HVI.
• Ceiling ventilator shall be Energy Star® qualified and have an
energy efficient permanent split capacitor motor.
• Ceiling Ventilator shall be U.L. Listed for use in insulated ceilings
(TypeI.C.)andforuseoverbathtubsandshowerswhenconnected
to a GFCI protected branch circuit.
* Use only one of the following 26W fluorescent lamps:
G.E. F26DBXT4/E/827
G.E. F26DBXT4/SPX27
PANASONIC FQ26E27/2
PHILIPS PL-26W/827/ALTO
OSRAM/SYLVANIA CF26DD/827
NEMA Type CFQ26W/G24D/827
NuTone 99271311
INSTALLATION
Complete installation instructions are included with each Fan /
Light / Night Light.
NuTone, Inc., 4820 Red Bank Road, Cincinnai, OH 45227 (1-800-543-8687)
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
60B
99043400E
Download from Www.Somanuals.com. All Manuals Search And Download.
|