Architectural & Engineering Specifications
February 2006
DESCRIPTION
QTRN Series
BLOWER:
•
Plug-in, permanently lubricated motor - engineered for
continuous operation
Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
Low RPM for quiet operation
Resilient anti-vibration motor mounts
•
Fan/Light/Night Lights
•
•
MODELS QTRN080L, QTRN110L
HOUSING:
•
•
Rugged, 26 gauge, galvanized steel construction
Polymeric, 4” duct connector with tapered sleeve and no
metallic clatter
•
•
•
7-5/8” height allows for 2” x 8” (nominal) joist installations
Sturdy, easy, four-point mounting directly to joist
Includes unique spacer (patent pending) for mounting to
engineered “I” joists
•
Can be mounted in ceilings up to 7/12 pitch
GRILLE:
•
•
Polymeric construction
Innovative design - the result of extensive research with
designers and consumers
•
•
•
100W incandescent lamp (bulb not included)
4W night light (bulb not included)
Durable steel reflector with white enamel finish
CONTROLS (Purchase separately):
ARCHITECT’S SPECIFICATION
•
Refer to NuTone’s catalog for a complete line of accessories
to effectively adapt these fans to your construction
requirements.
• CeilingVentilator shallbeNuToneModelQTRN080L(QTRN110L).
• Ceiling Ventilator shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be ducted to
a roof or wall cap using 4” round ductwork.
U.L. Listed for use over bathtubs and showers when connected
to a GFCI protected branch circuit (ceiling mount only).
U.L. Listed for use in insulated ceilings (TYPE I.C.)
3-Year Warranty
• Blower assembly shall be removable, have a centrifugal-type
blower wheel and a permanently lubricated motor designed for
continuous operation and mounted with resilient anti-vibration
mounts.
• Non-metallic damper/duct connector shall be included.
• Lamp shall be 100W incandescent with separate 4W night light.
• Air delivery shall be no less than 80 (110) CFM and sound level
no greater than 1.0 (1.5) Sones. All air and sound ratings shall be
certified by HVI.
• Ceiling Ventilator shall be U.L. Listed for use in insulated ceilings
(TypeI.C.)andforuseoverbathtubsandshowerswhenconnected
to a GFCI protected branch circuit.
INSTALLATION
Complete installation instructions are included with each Fan /
Light / Night Light.
NuTone, Inc., 4820 Red Bank Road, Cincinnai, OH 45227 (1-800-543-8687)
REFERENCE