INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Radiant Ceiling Heater
(single-bulb heat lamp)
MODEL: H-910W
JUNCTION BOX
LOCATION
Heater is to be located in ceiling of bathroom, mounted to
junction box installed on a ceiling joist, or if necessary on a
header between joists.
BOX
CONNECTOR
CAUTION: Do not mount heater closer than 8" to a vertical
surface. Do not mount heater over tub or in shower stall
enclosure.
FIGURE 1
MOUNTING JUNCTION BOX
(refer to specific section below)
When Ceiling Is In Place (see Figure 1)
1. Check attic or crawl space for wiring or other possible
obstruction to junction box. Return to bathroom and drill a
pilot hole through ceiling at the proposed location.
2. Locate the pilot hole in attic. Position a standard 4" octagon
junction box over pilot hole and next to ceiling joist. If ceiling
joist is not adjacent to pilot hole, install a header between
joists for mounting the junction box.
3. Mark ceiling for cutout, using the junction box as a template.
Make cutout in ceiling along outline of junction box.
GROUND
WHITE
BLACK
4. Run wiring to junction box (see WIRING section), then
mount box to joist or header, keeping edge of box flush to
ceiling.
MOUNTING
PLATE
When Mounting To Open Joist (see Figure 1)
Mount standard 4" octagon junction box to ceiling joist, or to
header.
WIRING
CEILING
PLATE
1. Heater may be wired to an existing lighting circuit, or run a
120vAC, 60Hz, 15 Amp circuit through a wall switch to
ceiling junction box (switch not included, see
ACCESSORIES).
2. Remove wiring knockout from junction box and install a box
connector. Feed wires through box connector, leaving
about 6" of wire in box for connections.
CAUTION: Be sure heater is properly grounded and all wiring
complies with local electrical code.
FIGURE 2
Download from Www.Somanuals.com. All Manuals Search And Download.
|