NuTone Electric Heater 9422P User Manual

SPECIFICATION SHEET  
MODELS 9422P & 9427P  
INFRARED  
BULB HEATERS  
TYPICALSPECIFICATION  
Quick and efficient, these twin-bulb heaters provide  
the selective temperature control you need.  
FEATURES  
Bulb heater shall be NuTone Model 9422P (NuTone Model  
9427P).  
White-white polymeric grille  
Heater shall have corrosion resistant steel housing and  
adjustable mounting brackets.  
Sturdy steel housing  
Adjustable mounting brackets that span up to 24"  
Housing can be adjusted vertically after ceiling is finished  
Unit must use (2) 250W BR40-size infrared bulbs. Bulb  
Heater to be U.L. Listed. Suitable for use in insulated ceilings  
(Type I.C.)  
Uses (2) 250W BR40-size infrared bulbs (not included)  
Bulbs may be operated separately or in combination  
using the following controls:  
Model 59W/V, 60-Minute Time Control  
Model 61W/V, 15-Minute Time Control  
Model 62W/V, 60-Minute Time Control with 2 Toggle  
Switches (Model 9427P only)  
MODEL 9427P BULB HEATER/FAN ONLY:  
Motorassemblytoberemovableandpermanentlylubricated.  
Non-metallic damper/duct connector to be included.  
Model63W/V, 60-MinuteTimeControlw/ToggleSwitch  
Model66W/V,Heat/Fan/LightControl(Model9427Ponly)  
Model 68W/V, Two-Function Control  
Heaterandventilatortooperateseparately(orincombination).  
Air delivery shall be no less than 70 CFM and sound level no  
greater than 3.5 Sones. All air and sound ratings shall be  
certified by HVI.  
Suitable for use in insulated ceilings (Type I.C.)  
MODEL 9427P BULB HEATER/FAN ONLY:  
Plug-in, permanently lubricated motor  
Quiet, polymeric blower wheel  
Polymericdamper/ductconnectorwith1-5/8" longtapered  
sleeve and no metallic clatter  
Unit may function with bulbs and fan controlled together,  
bulbs and fan controlled separately, or EACH bulb and fan  
controlled separately  
SPECIFICATIONS  
MODEL VOLTS  
AMPS WATTS* SONES  
CFM  
DUCT  
9422P  
9427P  
120  
120  
4.3  
4.5  
505**  
545**  
----  
3.5  
----  
----  
70  
4" Round  
* Total Connected Load  
** BR40-size Infrared Bulbs. Use house wiring rated 60°C min.  
HVI-2100CERTIFIEDRATINGScomplywithnewtestingtechnologies  
and procedures prescribed by the Home Ventilating Institute, for off-  
the-shelf products, as they are available to consumers. Product  
performance is rated at 0.1 in. static pressure, based on tests  
conducted in AMCA’s state-of-the-art test laboratory. Sones are a  
measure of humanly-perceived loudness, based on laboratory  
measurements.  
Model  
9422P  
Model  
9427P  
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)  
Product specifications subject to change without notice  
REFERENCE  
QTY.  
REMARKS  
Project  
Location  
Architect  
Engineer  
Contractor  
Submitted by  
Date  
50G  
99042989E  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NEC Car Video System OL V423 User Manual
NETGEAR Home Security System AGM732F User Manual
Nikon Camcorder Coolpix 8800 User Manual
Nostalgia Electrics Popcorn Poppers MHP 310 User Manual
Olivetti Printer PG L2028 User Manual
Onkyo Stereo System HT S580 User Manual
Panasonic Answering Machine KX TG6700 User Manual
Panasonic Car Stereo System CQ DP151 User Manual
Panasonic Network Card BL PA100 User Manual
Panasonic Telephone KXTGM240S User Manual