North Star Portable Generator 10000 PPG User Manual

MODEL 10000 PPG, ITEM #165967  
Professional Portable Generator  
M165967A  
P r o v e n P e r f o r m a n c e  
OWNER’S MANUAL  
Any Questions, Comments, or Problems?  
Call Customer Service at 1-800-270-0810  
Hours: Monday - Friday 7:00 AM to 5:30 PM CST  
Saturdays 7:30 AM to 11:30 AM CST  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Item Number  
Maximum Output  
Continuous Output  
Voltage  
#165967  
10000 Watts (W)  
8500 Watts (W)  
120/240 Volt (V)  
Phase  
Frequency  
Single phase (4-wire)  
56.5 - 63.3 Hertz (Hz)  
Power Factor  
Total Harmonic Distortion  
Engine  
1.0 p.f.  
less than 5%  
18 HP Honda  
3390 - 3798 RPM  
Engine Speed  
Fuel Type  
Fuel Capacity  
Oil Capacity  
Unleaded gasoline  
10 gallons (38.0 L)  
1.6 US quarts  
Starting Method  
Electric start/Recoil  
120 V Receptacles  
2 - 20 Amp (A) duplex (NEMA 5-20R)  
30 Amp (A) locking receptacle (NEMA L5-30R)  
30 Amp (A) locking receptacle (NEMA L14-30R)  
50 Amp (A) straight blade (NEMA 14-50R)  
40 Amp (A) thermal magnetic  
30 Amp (A) thermal magnetic  
30 Amp (A) thermal, push to reset  
2 - 20 Amp (A) thermal, push to reset  
12 VDC, 18 Amp-Hour (minimum)  
Group Size U1-7  
120/240 V Receptacle  
Circuit Breakers  
Battery  
Dimensions  
Length  
Width  
Height  
Dry Weight  
35.75” (90.8 cm)  
24.25” (61.6 cm)  
26.25” (66.7 cm)  
320 lb. (136 kg)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
MACHINE COMPONENT IDENTIFICATION  
Ref. Description  
Ref. Description  
1
2
Air Cleaner  
11  
12  
13  
14  
15  
16  
17  
18  
10.0 Gallon Gas Tank  
Grounding Screw  
Circuit Breakers  
Recoil  
Muffler & Spark Arrestor  
Oil Filter  
Battery Box  
Gas Line Valve  
Generator Head  
Gas Cap with Gauge  
3
4
5
6
7
120/240V, 50A Receptacle  
120/240V, 30A Locking Rec.  
120V, 30A Locking Rec.  
120V, 20A Duplex Rec.  
Oil Drain Plug  
8
9
Vibration Isolation Mount  
10  
Wheel Kit (#165919)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERATOR FEATURES  
Reference 13 - Muffler and Spark Arrestor.  
Reference 14 - Oil Filter.  
Reference 1 - Air Cleaner. Refer to your Honda  
Engine Owner’s Manual for air cleaner care.  
Reference 2 - Grounding Screw. Ground the  
generator via the grounding screw, to a copper pipe or  
rod that is driven into moist soil.  
Reference 3 - Circuit Breakers. This portable  
single phase generator has 1 - 40 amp (A) thermal  
magnetic 2 pole breaker, 1 - 30 amp (A) thermal  
magnetic 2 pole breaker 1 - 30 amp (A) push to reset  
circuit breaker, and 2 - 20 amp (A) push to reset circuit  
breakers. Circuit breakers protect against electrical  
overloads.  
Reference 15 - Battery Box. Warning: Always  
wear safety glasses when working on or near the  
battery. The battery box provides protection for the  
battery and will accept the standard lawn tractor size  
battery (Group U1-7). The engine requires a 12 volts  
dc battery, with a minimum rating of 18 Amp-Hours.  
When installing the battery, always connect the red  
colored (“positive” or “+”) cable first. When  
disconnecting the battery, always remove the black  
colored (“negative” or “-”) cable first.  
WARNING Sulfuric acid is a corrosive  
poison. Avoid contact with skin, eyes or clothing.  
Always wear safety glasses.  
Reference 16 - Gas Line Valve. The generator  
tank has an ON-OFF valve mounted underneath the  
Reference 4 - 120/240V  
Receptacle. This  
receptacle is a 120/240V 50A NEMA 14-50R  
receptacle. This receptacle accepts a NEMA 14-50P  
plug. Use this receptacle if installing a transfer switch.  
Reference 5 - 120/240V Locking Receptacle.  
This Locking is a 120/240V 30A NEMA L14-30R  
receptacle. This receptacle accepts a NEMA L14-30P  
plug.  
Reference 6 - 120V Locking Receptacle. This  
locking receptacle is a 120V 30A NEMA L5-30R  
receptacle. This receptacle accepts a NEMA L5-30P  
plug.  
Reference 7 - 120V Receptacle. The generator  
has a control panel with two duplex (two receptacles in  
a common housing) receptacles. Each duplex is a 120  
volt (V) 20 amp (A) straight blade receptacle, National  
Electrical Manufacturer’s Association (NEMA) number  
5-20R. This receptacle accepts NEMA plug numbers  
5-15P and 5-20P. Each duplex is capable of drawing  
20A at 120V.  
tank.  
Always keep this valve closed when the  
generator is not in use.  
Reference 17 - Generator Head. The electricity  
producing part of the generator.  
Reference 18 - Gas Cap with Gauge. The gas  
cap is extra large, creating a large hole for refilling and  
a comfortable grip. You can always monitor the fuel  
level without removing the cap by using the fuel level  
indicator built into the gas cap.  
Low Oil Shutdown.  
The Honda engine is  
protected against damage resulting from low engine  
oil. Always check your oil level daily.  
ALWAYS use grounded male plugs. The neutral  
line of the generator is mechanically grounded to the  
frame. Matching NEMA male plugs must always be  
used.  
WARNINGContact a licensed electrician  
to wire electrical plugs and/or cordsets. Improper  
wiring could result in a fire or electrical shock.  
Reference 8 - Oil Drain Plug. Refer to your  
Vanguard  
engine  
manual  
for  
oil  
change  
recommendations.  
Reference 9 - Vibration Isolation Mounts. The  
engine and generator head are mounted on rubber  
cylinders that absorb most of the engine vibration.  
This feature eliminates the tendency of the machine to  
“walk” which is common in engine powered equipment.  
Reference 10 - Wheel Kit. Heavy duty wheel kit  
(Item # 165919).  
Reference 11 - 10.0 Gallon Gas Tank. Large  
tank allows for extended run capabilities. Always  
allow room for gasoline expansion by not filling the gas  
tank completely  
Reference 12 - Recoil. Optional starting method.  
Grasp firmly when starting engine.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
ALWAYS use electrical cords that are in good  
condition. Worn, bare, frayed or otherwise damaged  
cords can cause electric shock.  
Before starting your generator, thoroughly study  
the instructions and cautions in this manual to assure  
you are fully acquainted with the operation of all  
components of this generator. Proper preparation,  
operation and maintenance will result in operator  
safety, best performance and long life of the generator.  
For detailed engine operation and maintenance always  
refer to the Vanguard engine owner’s manual  
furnished with the generator (Briggs and Stratton refer  
to the 18 HP engine as a 350447).  
NorthStar is constantly improving its products.  
The specifications outlined herein are subject to  
change without prior notice or obligation.  
purchaser and/or user assumes liability of any  
modification and/or alterations on this equipment from  
original design and manufacture.  
Before using, the user shall determine the  
suitability of this product for its intended use and  
assumes liability therein.  
NEVER operate the generator, or handle any  
electrical equipment while standing in water, while  
barefoot, while hands are wet or while in the rain or  
snow. Electric shock may result.  
ALWAYS use a ground fault circuit interrupter  
(GFCI) in damp or highly electrical conductive areas  
and on construction job-sites to prevent electric shock.  
ALWAYS remove the spark plug or spark plug  
wire before working on the engine or generator, to  
prevent accidental starting.  
The  
ALWAYS provide adequate ventilation. Do not  
operate generator in any enclosed or narrow space.  
Engines consume oxygen and give off deadly carbon  
monoxide poisonous gas. Improper ventilation will  
cause damage to generator and possible injury to  
people.  
ANSI SAFETY DEFINITIONS  
NEVER touch hot muffler, hot exhaust manifold or  
DANGER indicates an imminently hazardous  
situation which, if not avoided, will result in death or  
serious injury. This signal word is to be limited to the  
most extreme situations.  
engine cooling fins.  
ALWAYS remove all oil or gasoline deposits and  
accumulated dirt from generator and immediate area.  
Keep generator head and engine clean.  
WARNING indicates a potentially hazardous  
situation which, if not avoided, could result in a  
death or seri ous i nj ury.  
NEVER operate the generator under the following  
conditions:  
A. Excessive change in engine speed, slow or  
fast.  
B. Overheating in load connecting devices.  
C. Sparking or arcs from generator.  
D. Loss of electrical output.  
E. Damaged receptacles.  
CAUTION indicates a potentially hazardous  
situation, which if not avoided, may result in minor or  
moderate injury. It may also be used to alert against  
unsafe practices.  
F. Engine misfire.  
G. Excessive vibration.  
H. Enclosed compartments, or confined areas.  
I. Flame or smoke.  
RULES FOR SAFE OPERATIONS  
Safety precautions are essential when operating  
this generator. Respectful and cautious operation will  
considerably lessen the possibilities of a personal  
injury. This manual will warn of specific personal injury  
potential, and these will be designated by the symbol:  
J. Rain, snow or wet conditions.  
K. Operator non-attendance.  
WARNING Check fuel system on a  
regular basis. Look for signs of leaks, deterioration,  
chafed or spongy fuel hose, loose or missing fuel hose  
clamps, damaged fuel tank or a defective fuel shut-off  
valve. Correct any defects before operation.  
WARNING This generator is equipped  
WARNING Keep fire extinguisher close  
to your generator and be familiar with how to use it.  
Consult your local fire department for correct  
extinguisher type.  
with a grounding screw, located on the generator head  
for your protection. Always complete the grounding  
path from the generator to a copper pipe/rod that is  
driven into moist earth, to prevent electrical shock.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
tools, a capacity of up to the generator full rated  
wattage output can be used.  
OUTDOORS:  
Choose a location where the  
generator will not be exposed to rain, snow or direct  
sunlight. Position the generator on secure, level  
ground so it will not tip or slide down a hill. Place the  
generator so that the exhaust fumes will not be  
directed towards people.  
When connecting a resistive-inductive load such  
as a fluorescent or mercury light, transformers or  
inductive coils, a capacity of up to 0.6 times the  
generator’s full rated output can be used.  
Always allow the generator to reach operating  
speed before a load is applied.  
The installation site must be free from water,  
moisture, or dust. All electrical components should be  
protected from excessive moisture or the insulation  
system will deteriorate and result in grounding or  
shorting out the generating system.  
Foreign matters, such as dust, dirt, sand, lint, or  
abrasive materials can cause damage to the generator  
head and engine if allowed into its cooling system.  
NEVER install your generator inside confined  
areas. Inside installation can cause health hazards or  
death.  
STARTING ELECTRIC MOTORS  
Electric motors require much more current (amps)  
to start than to run. Some motors, particularly low cost  
split-phase motors, are very hard to start and require 5  
to 7 times more current to start than to run. Capacitor  
motors are easier to start and usually require 2 to 4  
times as much current to start as to run. Repulsion  
Induction motors are the easiest to start and require  
1.5 to 2.5 times as much to start as to run.  
Most fractional motors take about the same  
amount of current to run them whether they are of  
Repulsion-Induction (RI), Capacitor (Cap), or Split-  
Phase (SP) type. The following chart shows the  
approximate current required to start and run various  
types and sizes of 120 volt 60 cycle electric motors  
under various conditions.  
DANGER Remember, exhaust fumes are  
deadly carbon monoxide gas, and must be vented to  
the outside where there are no people. Cooling air of  
sufficient amounts must be allowed to flow in and  
exhausted out to ensure proper cooling of the engine  
and generator head.  
Starting Amps  
RI type Cap type SP type  
120V, 60 Hz Motors  
Hp motor Running  
Watts  
LOAD APPLICATION  
It is important to determine the total electrical load  
before it is connected to the generator. The two major  
factors in determining the life of a generator head are:  
heat build up, caused by overloading the generator;  
and corrosive contaminants that attack the wiring  
insulation. If the generator is overloaded, the wires  
become excessively hot and cause the insulation to  
break down, reducing its ability to resist corrosive  
contaminants. Over time the effectiveness of the  
insulation is eliminated and a dead short can result.  
Always compare the generator nameplate data  
with that of the equipment to be used to ensure that  
watts, volts, amperage, and frequency requirements  
are suitable for operating equipment. The wattage  
listed on the equipment nameplate is its rated output.  
However, some equipment may require three to ten  
times more wattage than its rating on the nameplate,  
as the wattage is influenced by the equipment  
efficiency, power factor and starting system. NOTE: If  
wattage is not given on equipment nameplate,  
approximate wattage may be determined by  
1/6  
1/4  
1/3  
1/2  
1
1 1/2  
2
3
525  
700  
875  
1175  
1925  
2400  
2900  
4075  
6750  
7-11  
9-15  
9-18  
12-23  
14-29  
20-40  
32-64  
40-80  
48-96  
68-136  
112-224  
16-22  
22-32  
26-35  
NA  
NA  
NA  
NA  
NA  
NA  
11-18  
15-25  
24-40  
30-50  
36-60  
51-85  
84-140  
5
The figures given above are for an average load  
such as a blower or fan. If the electric motor is  
connected to a hard starting load, such as an air  
compressor, it will require more starting current. If it is  
connected to a light load, such as a power saw, it will  
require less starting current. The exact requirement  
will also vary with the brand or design of the motor.  
Generators respond to severe overloading  
differently than the power line. When overloaded, the  
engine is not able to supply enough power to bring the  
electric motor up to operating speed. The generator  
responds to the high initial starting current, but the  
engine speed drops sharply. The overload may stall  
the engine. If allowed to operate at very low speeds,  
the electric motor starting winding will burn out in a  
short time. The generator head winding might also be  
damaged.  
multiplying  
amperage.  
nameplate voltage by nameplate  
VOLTS X AMPS = WATTS  
Example: 120V X 5A  
= 600W  
When connecting a resistive load such as  
incandescent lights, heaters or common electric power  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Load Requirements, continued  
Impact Wrench  
Jet Pump  
Lawn Mower  
Light Bulb  
Running the generator under these conditions may  
result in damage to the generator stator as well as the  
motor windings. Because the heavy surge of current  
is required for only an instant, the generator will not be  
damaged if it can bring the motor up to speed in a few  
500  
800  
1200  
100  
700  
1100 (a)  
300  
400  
225  
150  
4500  
600 (a)  
150  
200  
600 (b)  
200  
2800 (a)  
2000 (a)  
1500 (a)  
2000 (a)  
500  
1000  
250  
70  
3000  
500  
Microwave Oven  
Milk Cooler  
seconds.  
If difficulties in starting a motor are  
experienced, turn off all other electrical loads and if  
possible reduce the load on the electric motor.  
Oil Burner on Furnace  
Oil Fired Space Htr (140,000 Btu)  
Oil Fired Space Htr (85,000 Btu)  
Oil Fired Space Htr (30,000 Btu)  
Oven  
Paint Sprayer, Airless (1/3 HP)  
Paint Sprayer, Airless (handheld)  
Radio  
Refrigerator  
Slow Cooker  
Submersible Pump (1-1/2 HP)  
Submersible Pump (1 HP)  
Submersible Pump (1/2 HP)  
Table Saw (10”)  
EXTENSION CORDS  
When electric power is to be provided to various  
loads at some distance from the generator, extension  
cords can be used. These cords should be sized to  
allow for distance in length and amperage so that the  
voltage drop between the set and point of use is held  
to a minimum.  
Current/Power Maximum Extension Cord Length  
Amps  
Load  
#10  
#12  
#14  
#16  
Television  
Toaster  
Vacuum cleaner  
VCR  
Water Heater  
at  
240V  
(watts)  
Ga.  
Cord  
Ga.  
Cord  
Ga.  
Cord  
Ga.  
Cord  
10  
20  
30  
40  
50  
2400  
4800  
7200  
9600  
12000  
250’  
125’  
60’  
30’  
15’  
150’  
75’  
35’  
15’  
*
100’  
50’  
25’  
10’  
*
75’  
25’  
10’  
*
Weed Trimmer  
*
(a) Hard-starting motors require 3 to 5 times the  
rated running watts.  
(b) These loads may require up to 15 minutes to  
restart due to their normal build up of compressor  
head pressure.  
*Not recommended  
CAUTION: Equipment damage may result from  
the low voltage caused by using an extension cord  
wi th a sm all wi re si ze.  
NOTE: For extremely hard to start loads such as  
air conditioners and air compressors, consult the  
equipment dealer to determine the maximum wattage.  
For Determining Generator Load Requirements  
Device  
Running Watts  
1700 (a)  
500  
Air Conditioner (12,000 Btu)  
Battery Charger (20 Amp)  
Belt Sander (3”)  
Chain Saw  
PRE-START PREPARATIONS  
1000  
1200  
Your generator has been thoroughly tested prior to  
shipment from the factory. A factory test report has  
been included with this manual. However, damage  
can occur during shipping, so be sure to check for  
damaged parts or loose or missing nuts and bolts. If  
the aforementioned problems occur, call Customer  
Service at 1-800-270-0810.  
Circular Saw (6-1/2”)  
Coffee Maker  
900  
1000  
Compressor (1 HP)  
Compressor (3/4 HP)  
Compressor (1/2 HP)  
Curling Iron  
2000 (a)  
1800 (a)  
1400 (a)  
700  
Dishwasher  
1200  
Edge Trimmer  
500  
1200  
1500  
1250  
1200 (a)  
800 (b)  
1200  
1100  
875  
500  
250  
450  
150  
GROUNDING - All units must be grounded. Drive  
a 3/4” or 1” copper pipe or rod into the ground close to  
the machine. The pipe/rod must penetrate moist earth.  
Connect an approved ground clamp to the pipe. Run  
a 10 Ga. wire from the clamp to the generator  
grounding screw located on the generator head. Do  
not connect to a water pipe or a ground used by a  
radio system.  
Electric Nail Gun  
Electric Range (one element)  
Electric Skillet  
Furnace Fan (1/3 HP)  
Freezer  
Hair Dryer  
Hand Drill (1”)  
Hand Drill (1/2”)  
Hand Drill (3/8”)  
Hand Drill (1/4”)  
Hedge Trimmer  
Home Computer  
CAUTION: The engine has been shipped without  
oil. Fill the crankcase with oil before trying to start.  
Low oil shutdown prevents your generator from  
starting without sufficient oil.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING SPEED  
STARTING - MANUAL  
The generator must be run at the correct speed in  
order to produce the proper electrical voltage and  
frequency. The speed of the engine was carefully  
adjusted at the factory so that the generator produces  
the proper voltage and frequency.  
The output voltage should be checked to ensure  
the generator is working properly before connecting a  
load to the generator. Failure to do so could result in  
damage to equipment plugged into the unit and  
possible injury to the individual.  
All engines have a tendency to slow down when a  
load is applied. When the electrical load is connected  
to the generator, the engine is more heavily loaded,  
and as a result the speed drops slightly. This slight  
decrease in speed, together with the voltage drop  
within the generator itself, results in a slightly lower  
voltage when the generator is loaded to its full capacity  
than when it is running with no load. The slight  
variation has no appreciable effect in the operation of  
motors, lights and most appliances. Electronic  
equipment and clocks will be affected if correct RPM is  
not maintained. See Load vs. Output chart.  
1. Disconnect all loads to generator.  
2. Turn gas line valve to ON position.  
3. Turn key to the ON position.  
4. For cold engine, move choke lever to full choke  
position, for warm engine, move choke lever to half  
choke or to RUN position.  
5. Firmly grasp recoil handle and pull.  
6. When engine starts, move choke lever to RUN  
position.  
7. Loads may now be connected to generator.  
STARTING - ELECTRIC  
1. Disconnect all loads to generator.  
2. Turn gas line valve to ON position.  
3. For cold engine, move choke lever to full choke  
position, for warm engine, move choke lever to half  
choke or to RUN position.  
4. Turn key to start position.  
5. When engine starts, move choke lever to RUN  
position.  
6. Loads may now be connected to generator.  
Load  
Output  
Frequency  
Percent of  
Generator  
Output  
Speed  
(RPM)  
Generator  
Voltage at 120V  
Receptacle  
STOPPING  
(Hz)  
1. Disconnect all loads to generator.  
2. Turn engine key switch to OFF position.  
3. Turn gas line valve to OFF position.  
0 %  
50 %  
100 %  
3750  
3600  
3540  
62.5  
60.0  
59.0  
129V  
120V  
112V  
Output voltage should be checked periodically to  
ensure continued proper operation of the generating  
plant and appliances. It can be checked with a  
portable meter. Frequency can be checked by using  
an electric clock with a sweep second hand. Timed  
against a wristwatch or a stopwatch, the clock should  
be correct within +/- 2 seconds per minute. All speed  
setting adjustments should be done by a qualified  
technician.  
ENGINE CARE  
Refer to your Engine Owner’s Manual for proper  
care and maintenance.  
NOTE: When changing the oil on a hot engine, the  
oil might overshoot the oil drain hole on the generator  
base. Use a deflector (piece of cardboard or paper) to  
direct the oil down the hole.  
BEFORE STARTING  
1. Make sure the generator is positioned on firm  
l evel surface.  
2. Check the crankcase for oil and maintain at a  
proper level.  
3. Check fuel level and fill tank 7/8 full with fresh  
unleaded automotive gasoline. Never fill fuel tank  
completely to the top. Always wipe up and remove  
any spilled gasoline.  
4. Make sure that the exhaust fumes are directed  
away from people.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERATOR CARE  
The generator head is a two pole, 3600 RPM, 60  
Hz, brushless, revolving field and synchronous type  
with one sealed radial roller bearing. The rotor of the  
generator head is directly connected to the engine  
crankshaft and the stator is rigidly coupled to the  
engine casting via the generator head casting.  
Exercising the Generator - The generator  
should be operated every four weeks. Warm the  
unit up by starting the engine and letting it run for 10 to  
15 minutes. This will dry out any moisture that has  
accumulated in the windings. If left, this moisture can  
cause corrosion in the winding. Frequent operation of  
the engine/generator will also ensure that the set is  
operating properly should it be needed in an  
emergency.  
Generator Maintenance - The generator head is  
brushless and maintenance free. Any major generator  
service, including the installation or replacement of  
parts, should be performed by a qualified electrical  
service technician.  
USE ONLY FACTORY  
APPROVED REPAIR PARTS. Obtain factory parts  
from Customer Service at 1-800-270-0810.  
A. Bearing - The bearing used in these generators  
is a heavy duty sealed roller bearing. They require no  
maintenance or lubrication.  
B. Receptacles - Quality receptacles have been  
utilized. If a receptacle should become cracked or  
otherwise damaged, replace it. Using cracked or  
damaged receptacles can be both dangerous to the  
operator and destructive to the equipment.  
WARNING, Stand-by Operation  
If your generator is to be used as a standby  
electric power source in case of utility failure, it must  
be installed by a registered and licensed electrician  
and in compliance with all applicable state and local  
electrical codes. Also, local Fire Departments must be  
consulted concerning proper and safe handling  
procedures for gasoline. NEVER connect any  
generator to any existing electrical system without an  
isolating, UL approved transfer switch installed by a  
licensed electrician.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Problem  
Possible Causes  
Possible Remedies  
Engine will not start.  
a) Low oil level.  
b) Fouled spark plug.  
c) Out of fuel.  
a) Fill crankcase to proper oil level.  
b) Clean or replace spark plug.  
c) Fill fuel tank.  
d) Stop switch in OFF position.  
a) Engine speed too slow.  
d) Place switch in ON position.  
a) Bring generator to a qualified  
technician for adjustment.  
Voltage too low.  
b) Generator is overloaded.  
b) Reduce the load. (See Load  
Application section of this manual.)  
a) Disconnect load.  
Circuit breaker trips.  
Voltage too high.  
a) Defective load connected to generator.  
b) Defective receptacle.  
b) Replace receptacle.  
c) Generator overloaded.  
c) Reduce the load. (See Load  
Application section of this manual.)  
a) Bring generator to a qualified  
technician for adjustment.  
a) Engine speed too high.  
Generator overheating. a) Generator is overloaded.  
b) Insufficient ventilation.  
a) Reduce the load. (See Load  
Application section of this manual.)  
b) Make sure there is at least 3 feet of  
clearance on all sides of generator.  
a) Disconnect load.  
No output voltage.  
a) Defective load connected to generator.  
b) Broken or loose wire.  
b) Bring generator to a qualified  
technician for repair.  
c) Defective receptacle.  
d) Defective stator.  
c) Replace receptacle.  
d) Bring generator to a qualified  
technician for repair.  
e) Bring generator to a qualified  
technician for repair.  
e) Defective rotor.  
f) Defective capacitor.  
a) Generator is overloaded.  
f) Bring generator to a qualified  
technician for repair.  
a) Reduce the load. (See Load  
Application section of this manual.)  
b) Clean or replace air filter.  
a) Fill fuel tank.  
Engine lacks power.  
b) Dirty air filter.  
a) Out of fuel.  
b) Low oil level.  
Engine shuts down  
during operation.  
b) Fill crankcase to proper oil level.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miller Electric Welding System Regency 250 User Manual
Napoleon Fireplaces Indoor Fireplace EPA 1450 User Manual
NEC Projector V230 User Manual
Nextar GPS Receiver X3B User Manual
Omron Printer NT631 User Manual
One for All Universal Remote URC 7542 User Manual
Palsonic CRT Television 5169P User Manual
Panasonic Answering Machine KX TG5838AL User Manual
Panasonic DVD Player DMR EH535 User Manual
Panasonic Switch KX T61610 User Manual