Nortel Networks Switch NN46205 310 User Manual

Nortel Ethernet Routing Switch 8600  
Quick Start  
Release: 5.0  
Document Revision: 02.01  
NN46205-310  
321749-B Rev 01  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
5
.
Regulatory Information and Safety  
Precautions  
Read the information in this section to learn about regulatory conformities  
and compliances.  
International Regulatory Statements of Conformity  
This is to certify that the Nortel 8000 Series chassis and components  
installed within the chassis were evaluated to the international regulatory  
standards for electromagnetic compliance (EMC) and safety and were  
found to have met the requirements for the following international  
standards:  
EMC—Electromagnetic Emissions—CISPR 22, Class A  
EMC—Electromagnetic Immunity—CISPR 24  
Electrical Safety—IEC 60950, with CB member national deviations  
Further, the equipment has been certified as compliant with the national  
standards as detailed in the following sections.  
National Electromagnetic Compliance (EMC) Statements of  
Compliance  
FCC Statement (USA only)  
This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to Part 15 of the Federal Communications  
Commission (FCC) rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can  
radiate radio frequency energy. If it is not installed and used in accordance  
with the instruction manual, it may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely  
to cause harmful interference, in which case users will be required to take  
whatever measures may be necessary to correct the interference at their  
own expense.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
6
Regulatory Information and Safety Precautions  
ICES Statement (Canada only)  
Canadian Department of Communications Radio Interference  
Regulations  
This digital apparatus (8000 Series chassis and installed components)  
does not exceed the Class A limits for radio-noise emissions from  
digital apparatus as set out in the Radio Interference Regulations of the  
Canadian Department of Communications.  
Règlement sur le brouillage radioélectrique du ministère des  
Communications  
Cet appareil numérique (8000 Series chassis) respecte les limites de bruits  
radioélectriques visant les appareils numériques de classe A prescrites  
dans le Règlement sur le brouillage radioélectrique du ministère des  
Communications du Canada.  
CE Marking Statement (Europe only)  
EN 55 022 Statements  
This is to certify that the Nortel 8000 Series chassis and components  
installed within the chassis are shielded against the generation of radio  
interference in accordance with the application of Council Directive  
2004/108/EC. Conformity is declared by the application of EN 55 022  
Class A (CISPR 22).  
CAUTION  
This device is a Class A product. Operation of this equipment  
in a residential area is likely to cause harmful interference, in  
which case users are required to take appropriate measures  
necessary to correct the interference at their own expense.  
EN 55 024 Statement  
This is to certify that the Nortel 8000 Series chassis is shielded against the  
susceptibility to radio interference in accordance with the application of  
Council Directive 2004/108/EC. Conformity is declared by the application  
of EN 55 024 (CISPR 24).  
EN 300386 Statement  
The Ethernet Routing Switch 8000 Series chassis complies with the  
requirements of EN 300386 V1.3.3 for emissions and for immunity for a  
Class A device intended for use in either Telecommunications centre or  
locations other than telecommunications centres given the performance  
criteria as specified by the manufacturer.  
EC Declaration of Conformity  
This product conforms to the provisions of the R&TTE Directive  
1999/5/EC.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
National Electromagnetic Compliance (EMC) Statements of Compliance  
7
European Union and European Free Trade Association (EFTA) Notice  
All products labeled with the CE marking comply with R&TTE Directive  
(1999/5/EEC) which includes the Electromagnetic Compliance (EMC)  
Directive (2004/108/EC) and the Low Voltage Directive (2006/95/EC)  
issued by the Commission of the European Community.  
Compliance with these directives implies conformity to the following  
European Norms (ENs). The equivalent international standards are listed  
in parenthesis.  
EN 55022 (CISPR 22)–Electromagnetic Interference  
EN 55024 (IEC 61000-4-2, -3, -4, -5, -6, -8, -11)–Electromagnetic  
Immunity  
EN 61000-3-2 (IEC 610000-3-2)–Power Line Harmonics  
EN 61000-3-3 (IEC 610000-3-3)–Power Line Flicker  
VCCI Statement (Japan/Nippon only)  
This is a Class A product based on the standard of the Voluntary Control  
Council for Interference (VCCI) for information technology equipment.  
If this equipment is used in a domestic environment, radio disturbance  
may arise. When such trouble occurs, the user may be required to take  
corrective actions.  
BSMI Statement for 8010, 8006 and 8003 Chassis (Taiwan only)  
This is a Class A product based on the standard of the Bureau of  
Standards, Metrology and Inspection (BSMI) CNS 13438, Class A.  
MIC Notice for 8010, 8006, 8003 Chassis (Republic of Korea only)  
This device has been approved for use in Business applications only per  
the Class A requirements of the Republic of Korea Ministry of Information  
and Communications (MIC). This device may not be sold for use in a  
non-business application.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
8
Regulatory Information and Safety Precautions  
National Safety Statements of Compliance  
CE Marking Statement (Europe only)  
EN 60 950 Statement  
This is to certify that the Nortel 8000 Series chassis and components  
installed within the chassis are in compliance with the requirements of EN  
60 950 in accordance with the Low Voltage Directive. Additional national  
differences for all European Union countries have been evaluated for  
compliance. Some components installed within the 8000 Series chassis  
may use a nickel-metal hydride (NiMH) and/or lithium-ion battery. The  
NiMH and lithium-ion batteries are long-life batteries, and it is very possible  
that you will never need to replace them. However, should you need to  
replace them, refer to the individual component manual for directions on  
replacement and disposal of the battery.  
NOM Statement 8010, 8006, and 8003 Chassis (Mexico only)  
The following information is provided on the devices described in this  
document in compliance with the safety requirements of the Norma Oficial  
Méxicana (NOM):  
Exporter:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara CA 95054 USA  
Importer:  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Piso 30, Oficina  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
National Safety Statements of Compliance  
9
México D.F. 03900  
52 5 480 2100  
52 5 480 2199  
Model 8003AC:  
Tel:  
Fax:  
Input:  
100-240 VAC, 50-60 Hz, 9 A maximum for each power  
supply  
Model 8004AC:  
100-240 VAC, 50-60 Hz, 12-6 A maximum for each  
power supply  
Model 8005AC:  
100-120 VAC, 50-60 Hz, 16 A maximum for each  
power supply  
200-240 VAC, 50-60 Hz, 8.5 A maximum for each  
power supply  
Model 8005DI AC:  
100-120 VAC, 50-60 Hz, 16 A maximum for each  
power supply  
200-240 VAC, 50-60 Hz, 9.3 A maximum for each  
power supply  
Model 8004DC:  
48-60 VDC, 29-23 A  
Model 8005DC:  
48-60 VDC, 42-34 A  
Información NOM (unicamente para México)  
La información siguiente se proporciona en el dispositivo o en los  
dispositivos descritos en este documento, en cumplimiento con los  
requisitos de la Norma Oficial Méxicana (NOM):  
Exportador:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara, CA 95054 USA  
Importador:  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Piso 30, Oficina  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
10 Regulatory Information and Safety Precautions  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
México D.F. 03900  
52 5 480 2100  
Tel:  
52 5 480 2199  
Fax:  
Embarcar a:  
Model 8003AC:  
100-240 VCA, 50-60 Hz, 9 A max. por fuente de poder  
Model 8004AC:  
100-240 VCA, 50-60 Hz, 12-6 A max. por fuente de  
poder  
Model 8005AC:  
100-120 VCA, 50-60 Hz, 16 A max. por fuente de  
poder  
200-240 VCA, 50-60 Hz, 9.5 A max. por fuente de  
poder  
Model 8005DI AC:  
100-120 VCA, 50-60 Hz, 16 A max por fuente de poder  
200-240 VCA, 50-60 Hz, 9.3 A max por fuente de  
poder  
Model 8004DC:  
-48 VCD, 29 A  
Model 8005DC:  
-48 VCD, 42 A  
Denan Statement (Japan/Nippon only)  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety Messages 11  
Safety Messages  
This section describes the different precautionary notices used in this  
document. This section also contains precautionary notices that you must  
read for safe operation of the Nortel Ethernet Routing Switch 8600.  
Notices  
Notice paragraphs alert you about issues that require your attention.  
The following sections describe the types of notices. For a list of safety  
messages used in this guide and their translations, see "Translations of  
safety messages".  
Attention Notice  
ATTENTION  
An attention notice provides important information regarding the installation and  
operation of Nortel products.  
Caution ESD Notice  
CAUTION  
ESD  
ESD notices provide information about how to avoid discharge  
of static electricity and subsequent damage to Nortel products.  
CAUTION  
ESD (décharge électrostatique)  
La mention ESD fournit des informations sur les moyens de  
prévenir une décharge électrostatique et d’éviter d’endommager  
les produits Nortel.  
CAUTION  
ACHTUNG ESD  
ESD-Hinweise bieten Information dazu, wie man die  
Entladung von statischer Elektrizität und Folgeschäden an  
Nortel-Produkten verhindert.  
CAUTION  
PRECAUCIÓN ESD (Descarga electrostática)  
El aviso de ESD brinda información acerca de cómo evitar  
una descarga de electricidad estática y el daño posterior a los  
productos Nortel.  
CAUTION  
CUIDADO ESD  
Os avisos do ESD oferecem informações sobre como evitar  
descarga de eletricidade estática e os conseqüentes danos aos  
produtos da Nortel.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
12 Regulatory Information and Safety Precautions  
CAUTION  
ATTENZIONE ESD  
Le indicazioni ESD forniscono informazioni per evitare scariche  
di elettricità statica e i danni correlati per i prodotti Nortel.  
Caution Notice  
CAUTION  
Caution notices provide information about how to avoid possible  
service disruption or damage to Nortel products.  
CAUTION  
ATTENTION  
La mention Attention fournit des informations sur les moyens  
de prévenir une perturbation possible du service et d’éviter  
d’endommager les produits Nortel.  
CAUTION  
ACHTUNG  
Achtungshinweise bieten Informationen dazu, wie man mögliche  
Dienstunterbrechungen oder Schäden an Nortel-Produkten  
verhindert.  
CAUTION  
PRECAUCIÓN  
Los avisos de Precaución brindan información acerca de  
cómo evitar posibles interrupciones del servicio o el daño a los  
productos Nortel.  
CAUTION  
CUIDADO  
Os avisos de cuidado oferecem informações sobre como evitar  
possíveis interrupções do serviço ou danos aos produtos da  
Nortel.  
CAUTION  
ATTENZIONE  
Le indicazioni di attenzione forniscono informazioni per evitare  
possibili interruzioni del servizio o danni ai prodotti Nortel.  
Warning Notice  
WARNING  
Warning notices provide information about how to avoid  
personal injury when working with Nortel products.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety Messages 13  
WARNING  
AVERTISSEMENT  
La mention Avertissement fournit des informations sur  
les moyens de prévenir les risques de blessure lors de la  
manipulation de produits Nortel.  
WARNING  
WARNUNG  
Warnhinweise bieten Informationen dazu, wie man  
Personenschäden bei der Arbeit mit Nortel-Produkten  
verhindert.  
WARNING  
ADVERTENCIA  
Los avisos de Advertencia brindan información acerca de cómo  
prevenir las lesiones a personas al trabajar con productos  
Nortel.  
WARNING  
AVISO  
Os avisos oferecem informações sobre como evitar ferimentos  
ao trabalhar com os produtos da Nortel.  
WARNING  
AVVISO  
Le indicazioni di avviso forniscono informazioni per evitare danni  
alle persone durante l’utilizzo dei prodotti Nortel.  
Danger High Voltage Notice  
DANGER  
Danger—High Voltage notices provide information about how to  
avoid a situation or condition that can cause serious personal  
injury or death from high voltage or electric shock.  
DANGER  
La mention Danger—Tension élevée fournit des informations  
sur les moyens de prévenir une situation ou une condition qui  
pourrait entraîner un risque de blessure grave ou mortelle à la  
suite d’une tension élevée ou d’un choc électrique.  
DANGER  
GEFAHR  
Hinweise mit Vorsicht – Hochspannung“ bieten Informationen  
dazu, wie man Situationen oder Umstände verhindert, die zu  
schweren Personenschäden oder Tod durch Hochspannung  
oder Stromschlag führen können.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
14 Regulatory Information and Safety Precautions  
DANGER  
PELIGRO  
Los avisos de Peligro-Alto voltaje brindan información acerca  
de cómo evitar una situación o condición que cause graves  
lesiones a personas o la muerte, a causa de una electrocución  
o de una descarga de alto voltaje.  
DANGER  
PERIGO  
Avisos de Perigo—Alta Tensão oferecem informações sobre  
como evitar uma situação ou condição que possa causar graves  
ferimentos ou morte devido a alta tensão ou choques elétricos.  
DANGER  
PERICOLO  
Le indicazioni Pericolo—Alta tensione forniscono informazioni  
per evitare situazioni o condizioni che potrebbero causare gravi  
danni alle persone o il decesso a causa dell’alta tensione o di  
scosse elettriche.  
Danger Notice  
DANGER  
Danger notices provide information about how to avoid a  
situation or condition that can cause serious personal injury or  
death.  
DANGER  
La mention Danger fournit des informations sur les moyens de  
prévenir une situation ou une condition qui pourrait entraîner un  
risque de blessure grave ou mortelle.  
DANGER  
GEFAHR  
Gefahrenhinweise stellen Informationen darüber bereit, wie  
man Situationen oder Umständen verhindert, die zu schweren  
Personenschäden oder Tod führen können.  
DANGER  
PELIGRO  
Los avisos de Peligro brindan información acerca de cómo  
evitar una situación o condición que pueda causar lesiones  
personales graves o la muerte.  
DANGER  
PERIGO  
Avisos de perigo oferecem informações sobre como evitar uma  
situação ou condição que possa causar graves ferimentos ou  
morte.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety Messages 15  
DANGER  
PERICOLO  
Le indicazioni di pericolo forniscono informazioni per evitare  
situazioni o condizioni che potrebbero causare gravi danni alle  
persone o il decesso.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
16 Regulatory Information and Safety Precautions  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
17  
.
Software license  
This section contains the Nortel Networks software license.  
Nortel Networks Inc. software license agreement  
This Software License Agreement ("License Agreement") is between  
you, the end-user ("Customer") and Nortel Networks Corporation and  
its subsidiaries and affiliates ("Nortel Networks"). PLEASE READ THE  
FOLLOWING CAREFULLY. YOU MUST ACCEPT THESE LICENSE  
TERMS IN ORDER TO DOWNLOAD AND/OR USE THE SOFTWARE.  
USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF  
THIS LICENSE AGREEMENT. If you do not accept these terms and  
conditions, return the Software, unused and in the original shipping  
container, within 30 days of purchase to obtain a credit for the full  
purchase price.  
"Software" is owned or licensed by Nortel Networks, its parent or one of  
its subsidiaries or affiliates, and is copyrighted and licensed, not sold.  
Software consists of machine-readable instructions, its components, data,  
audio-visual content (such as images, text, recordings or pictures) and  
related licensed materials including all whole or partial copies. Nortel  
Networks grants you a license to use the Software only in the country  
where you acquired the Software. You obtain no rights other than those  
granted to you under this License Agreement. You are responsible for the  
selection of the Software and for the installation of, use of, and results  
obtained from the Software.  
1. Licensed Use of Software. Nortel Networks grants Customer a  
nonexclusive license to use a copy of the Software on only one machine  
at any one time or to the extent of the activation or authorized usage level,  
whichever is applicable. To the extent Software is furnished for use with  
designated hardware or Customer furnished equipment ("CFE"), Customer  
is granted a nonexclusive license to use Software only on such hardware  
or CFE, as applicable. Software contains trade secrets and Customer  
agrees to treat Software as confidential information using the same care  
and discretion Customer uses with its own similar information that it does  
not wish to disclose, publish or disseminate. Customer will ensure that  
anyone who uses the Software does so only in compliance with the terms  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
18 Software license  
of this Agreement. Customer shall not a) use, copy, modify, transfer  
or distribute the Software except as expressly authorized; b) reverse  
assemble, reverse compile, reverse engineer or otherwise translate the  
Software; c) create derivative works or modifications unless expressly  
authorized; or d) sublicense, rent or lease the Software. Licensors of  
intellectual property to Nortel Networks are beneficiaries of this provision.  
Upon termination or breach of the license by Customer or in the event  
designated hardware or CFE is no longer in use, Customer will promptly  
return the Software to Nortel Networks or certify its destruction. Nortel  
Networks may audit by remote polling or other reasonable means to  
determine Customer’s Software activation or usage levels. If suppliers of  
third party software included in Software require Nortel Networks to include  
additional or different terms, Customer agrees to abide by such terms  
provided by Nortel Networks with respect to such third party software.  
2. Warranty. Except as may be otherwise expressly agreed to in  
writing between Nortel Networks and Customer, Software is provided  
"AS IS" without any warranties (conditions) of any kind. NORTEL  
NETWORKS DISCLAIMS ALL WARRANTIES (CONDITIONS) FOR THE  
SOFTWARE, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT  
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF  
NON-INFRINGEMENT. Nortel Networks is not obligated to provide support  
of any kind for the Software. Some jurisdictions do not allow exclusion  
of implied warranties, and, in such event, the above exclusions may not  
apply.  
3. Limitation of Remedies. IN NO EVENT SHALL NORTEL  
NETWORKS OR ITS AGENTS OR SUPPLIERS BE LIABLE FOR ANY  
OF THE FOLLOWING: a) DAMAGES BASED ON ANY THIRD PARTY  
CLAIM; b) LOSS OF, OR DAMAGE TO, CUSTOMER’S RECORDS,  
FILES OR DATA; OR c) DIRECT, INDIRECT, SPECIAL, INCIDENTAL,  
PUNITIVE, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST  
PROFITS OR SAVINGS), WHETHER IN CONTRACT, TORT OR  
OTHERWISE (INCLUDING NEGLIGENCE) ARISING OUT OF  
YOUR USE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS,  
ITS AGENTS OR SUPPLIERS HAVE BEEN ADVISED OF THEIR  
POSSIBILITY. The forgoing limitations of remedies also apply to any  
developer and/or supplier of the Software. Such developer and/or supplier  
is an intended beneficiary of this Section. Some jurisdictions do not allow  
these limitations or exclusions and, in such event, they may not apply.  
4. General  
1. If Customer is the United States Government, the following paragraph  
shall apply: All Nortel Networks Software available under this License  
Agreement is commercial computer software and commercial computer  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Nortel Networks Inc. software license agreement 19  
software documentation and, in the event Software is licensed for  
or on behalf of the United States Government, the respective rights  
to the software and software documentation are governed by Nortel  
Networks standard commercial license in accordance with U.S. Federal  
Regulations at 48 C.F.R. Sections 12.212 (for non-DoD entities) and  
48 C.F.R. 227.7202 (for DoD entities).  
2. Customer may terminate the license at any time. Nortel Networks  
may terminate the license if Customer fails to comply with the terms  
and conditions of this license. In either event, upon termination,  
Customer must either return the Software to Nortel Networks or certify  
its destruction.  
3. Customer is responsible for payment of any taxes, including personal  
property taxes, resulting from Customer’s use of the Software.  
Customer agrees to comply with all applicable laws including all  
applicable export and import laws and regulations.  
4. Neither party may bring an action, regardless of form, more than two  
years after the cause of the action arose.  
5. The terms and conditions of this License Agreement form the complete  
and exclusive agreement between Customer and Nortel Networks.  
6. This License Agreement is governed by the laws of the country in  
which Customer acquires the Software. If the Software is acquired in  
the United States, then this License Agreement is governed by the  
laws of the state of New York.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
20 Software license  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
21  
.
New in this release  
The following sections detail what’s new in Nortel Ethernet Routing Switch  
8600 Quick Start , (NN46205-310) for Release 5.0.  
Features  
See the following sections for information about changes that are feature  
related:  
Nortel Command Line Interface  
The Nortel Ethernet Routing Switch 8600 uses the Nortel Networks  
Command Line Interface (NNCLI). This document provides configuration  
instructions for existing features using the NNCLI.  
Other changes  
See the following sections for information about the changes that are not  
feature related:  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
       
22 New in this release  
Connecting the modem using the CLI  
This section describes how to connect a modem to the modem port on  
an SF/CPU module using the CLI command. You can access the CLI  
through a modem connection to the Ethernet Routing Switch 8690SF,  
8691SF/CPU, or 8692SF/CPU modules.  
Connecting the modem using the NNCLI  
This section describes how to connect a modem to the modem port on an  
SF/CPU module using the NNCLI command. You can access the NNCLI  
through a modem connection to the Ethernet Routing Switch 8690SF,  
8691SF/CPU, or 8692SF/CPU modules.  
56).  
Setting the system date and time using the CLI  
This section describes the instructions to set the system date and time  
using the CLI.  
Setting the system date and time using the NNCLI  
This section describes the instructions to set the system date and time  
using the NNCLI.  
Changing passwords using the CLI  
This section describes the instructions to set new passwords for each  
access level, or change the logon password for the different switch access  
using the CLI.  
Changing passwords using the NNCLI  
This section describes the instructions to set new passwords for each  
access level, or change the logon password for the different switch access  
using the NNCLI.  
63).  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
           
23  
.
Introduction  
The Nortel Ethernet Routing Switch 8600 Quick Start, NN46205-310  
provides basic instructions about installing the hardware and performing  
basic configuration of the Ethernet Routing Switch 8010, 8006, 8003, and  
8010co chassis and software.  
Navigation  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
24 Introduction  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
25  
.
Installation preparation  
This section provides basic information about the Ethernet Routing Switch  
8600 slots. It also include a checklist of the shipped accessories.  
Navigation  
Ethernet Routing Switch 8600 slots  
The Ethernet Routing Switch 8010co chassis provides eight slots for  
installing Ethernet Routing Switch 8600 interface modules and two slots  
for installing the Ethernet Routing Switch 8691SF/CPU and 8692SF/CPU  
(switch fabric) modules. Slots are numbered from left to right. Install  
Ethernet Routing Switch 8600 interface modules in slots 1 to 4 and 7  
to10. Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 Series  
SF/CPU modules.  
The 8010 chassis provides eight slots for installing Ethernet Routing  
Switch 8600 interface modules and two slots for installing Ethernet Routing  
Switch 8691SF/CPU or 8692SF/CPU modules. Slots are numbered from  
top to bottom. Install Ethernet Routing Switch 8600 interface modules in  
slots 1 to 4 and 7 to 10. Slots 5 and 6 are reserved for Ethernet Routing  
Switch 8600 SF/CPU modules.  
The 8006 chassis provides four slots for installing Ethernet Routing Switch  
8600 interface modules and two slots for installing Ethernet Routing Switch  
8691SF/CPU or 8692SF/CPU modules. Slots are numbered from top to  
bottom. Install Ethernet Routing Switch 8600 interface modules in slots 1  
to 4. Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 SF/CPU  
modules.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
26 Installation preparation  
The 8003 chassis provides two slots for installing Ethernet Routing Switch  
8600 interface modules and one slot for installing an Ethernet Routing  
Switch 8691/CPU Module. Slots are numbered from top to bottom.  
DC power supply accessories  
The DC power supply shipment contains hardware accessories. Use the  
following checklist to verify the contents of the 8004DC shipping container.  
Table 1  
8004DC power supply shipping accessories  
Check  
Accessory  
Use to  
Two 2-hole crimp  
lug terminals with  
attached tubing  
(8004)  
Connect the positive  
and negative power  
inputs  
One 1-hole crimp  
lug terminal with  
attached tubing  
Connect the ground  
stud  
5 nuts  
Connect all leads  
Connect all leads  
5 lock washers  
1 washer  
Connect the ground  
stud  
Use the following checklist to verify the contents of the 8005DC shipping  
container.  
Table 2  
8005DC power supply shipping accessories  
Check  
Accessory  
Use to  
Three 2-hole crimp  
lug terminals with  
attached tubing  
Connect the positive  
and negative power  
inputs  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Safety precautions 27  
Check  
Accessory  
Use to  
6 nuts  
Connect all leads  
Connect all leads  
6 lock washers  
2 washers  
Connect the ground  
stud  
Safety precautions  
This section describes the safety precautions which are vital for handling  
and installing the Ethernet Routing Switch 8600.  
Safety precautions navigation  
Personal safety  
For your safety, review the following personal safety warnings before  
working with the Ethernet Routing Switch 8600.  
DANGER  
Risk of injury by fan blades  
When removing the fan module, do not put your hands into the  
opening because of the spinning fan blades in the adjacent fan  
modules.  
WARNING  
Risk of personal injury  
Grasp the fan tray at the middle of the front panel, and be  
careful to keep your fingers out of the fan blades.  
DANGER  
Risk of injury by electric shock  
The electrical connector at the rear of the slot poses a risk of  
electrical shock.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
28 Installation preparation  
WARNING  
Risk of eye injury by laser  
Fiber optic equipment can emit laser or infrared light that can  
injure your eyes. Never look into an optical fiber or connector  
port. Always assume that fiber optic cables are connected to a  
light source.  
Module safety  
Use the following general practices to prevent the equipment damage  
when working with the Ethernet Routing Switch 8600.  
Always wear an antistatic wrist strap that is connected to an  
Electrostatic discharge (ESD) grounding jack when handling modules.  
Always set modules on appropriate antistatic material.  
Handle modules using the faceplate. Do not touch pins or electrical  
connections.  
Do not leave slots open. Fill all the slots with modules, or use slot  
covers to maintain safety compliance, proper cooling, and EMI  
containment in the chassis.  
Ensure your environment meets the requirements for temperature,  
humidity, and cleanliness.  
Replace the 8010co chassis air filter regularly (approximately every  
three months) to maintain proper cooling and airflow.  
For instructions to replace the 8010co chassis air filter, see Nortel  
Ethernet Routing Switch 8600 Routine Maintenance, NN46205-312.  
Do not overtighten thumb screws or lug nuts. Tighten screws and nuts  
until snug plus a quarter turn. If you use a power tool to tighten screws,  
use a low torque setting (2 to 3 inches per pound [in./lb]).  
Cable and connector safety  
Use the following instructions to safeguard cables and connectors while  
working with the Ethernet Routing Switch 8600.  
Support cables to prevent stress on connectors. If the Ethernet Routing  
Switch 8600 has a high cable-density configuration, install additional  
cable-management equipment.  
Do not exceed the bend radius recommended for the cable type  
installed.  
Fiber optic cables and connectors require special care.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Safety precautions 29  
Protect connectors with rubber safety plugs when cables are not  
inserted.  
Follow appropriate fiber-cleaning procedures to install or replace  
cables.  
Do not exceed the bend radius recommended for fiber optic cables.  
The acceptable bend radius for fiber optic cable is ten times  
its diameter, or 2.5 to 5 cm (1 to 2 in.). Anything less than the  
recommendation can cause a loss of integrity during data transmission.  
It is difficult to diagnose loss of integrity because of incorrect bend  
radius.  
Electrostatic discharge safety  
Electrostatic discharge (ESD) is the transfer of charge between objects at  
different electrical potentials. ESD can change the electrical characteristics  
and degrade or destroy a semiconductor device. ESD can also disrupt  
the normal operation of an electronic system by causing equipment  
malfunction or failure.  
To dissipate or neutralize electrostatic charges, use proper grounding and  
conductive or dissipative materials.  
CAUTION  
Risk of equipment damage  
To prevent damage from electrostatic discharge, always wear  
an antistatic wrist strap connected to an electrostatic discharge  
(ESD) jack.  
Proper antistatic packaging effectively shields products from electrostatic  
charges and reduces the charge generation caused by product movement  
within the container.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
30 Installation preparation  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
32 Installation  
Unpacking the chassis  
Unpack the shipping container to ensure the chassis and all accessories  
are included and undamaged.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Removing a power filler panel 33  
Procedure steps  
Step  
1
Action  
Remove the equipment from the shipping container and place  
the chassis on antistatic material.  
2
Check all items for damage.  
ATTENTION  
If the equipment is damaged, contact your Nortel sales  
representative.  
3
Use the following chassis shipping accessories checklist to verify  
that the shipping container includes all contents.  
Check  
Accessory  
Use to  
Bracket kit: two  
rack-mounting brackets  
and Phillips-head screws.  
Support the chassis in an  
equipment rack.  
Screw package  
Mount the chassis in an  
equipment rack.  
Side cable-management  
bracket: two brackets for  
the 8010 chassis and one  
bracket for the 8006 and  
8003 chassis  
Manage network interface  
cables.  
Rubber footpads  
Keep the chassis from  
slipping when mounting  
on a flat surface.  
Console cable with built-in Connect an optional  
adapter.  
management console to  
the chassis. Each cable  
end has a female DB9  
and a DB25 connector.  
Cable guide  
Keep cable clusters  
fastened and out of the  
way, but accessible for  
maintenance.  
--End--  
Removing a power filler panel  
A power filler panel maintains the proper cooling airflow in the Ethernet  
Routing Switch 8600 chassis. You must remove the power filler panel from  
the power bay when you install a power supply in a bay for the first time  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
34 Installation  
Procedure steps  
Step  
1
Action  
Use a Phillips screwdriver to loosen the two screws that fasten  
the filler panel to the chassis.  
2
Pull the filler panel away from the slot as shown in the following  
figure.  
--End--  
Installing an Ethernet Routing Switch 8003, 8006, or 8010 chassis  
into a rack  
Install an Ethernet Routing Switch 8003, 8006, or 8010 chassis in a  
standard equipment rack (19-inch).  
Prerequisites for installing an Ethernet Routing Switch 8003, 8006, or  
8010 chassis into a rack  
Remove any filler panels before you install the chassis to decrease the  
weight during installation.  
Procedure steps  
Step  
1
Action  
Hold each rack-mounting bracket to the sides of the chassis, and  
align the screw holes.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing an Ethernet Routing Switch 8003, 8006, or 8010 chassis into a rack 35  
2
Attach the brackets to the chassis using the supplied  
Phillips-head screws.  
WARNING  
Risk of personal injury  
It requires two people to lift a fully-loaded chassis. To  
prevent injury, keep your back straight and lift with  
your legs.  
An Ethernet Routing Switch 8010 chassis weighs  
approximately 101 kg (225 lbs).  
An Ethernet Routing Switch 8006 chassis weighs  
approximately 77 kg (170 lbs).  
An Ethernet Routing Switch 8003 chassis weighs  
approximately 49.5 kg (110 lbs).  
3
Hold the chassis in position and align the flanged end of each  
mounting rail with the two holes on each side of the vertical rack  
support.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
36 Installation  
4
Insert and tighten the rack-mounting screws with a Phillips  
screwdriver.  
--End--  
Installing the 8010co chassis in a 19-inch two-post rack  
Install the 8010co chassis in a 19-inch two-post rack.  
Prerequisites  
Verify that you have the following tools and materials:  
12 Phillips-head screws  
1 Phillips screwdriver  
Procedure steps  
Step  
1
Action  
Place the installation shelf at the bottom of the rack and inside  
the rails.  
2
3
Hold the installation shelf in position and align the shelf mounting  
rail with the two holes on each side of the vertical rack support.  
Insert a Phillips-head screw through each installation shelf  
mounting hole and into the corresponding hole in the rack.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing the 8003, 8006, and 8010 chassis cable guides 37  
4
5
6
Add a hex nut to each screw and tighten using a hex wrench.  
Tighten each screw using a Phillips-head screwdriver.  
If the holes in the rack vertical supports require clip nuts, insert a  
clip nut into each of the 12 locations.  
7
Lift the 8010co chassis onto the installation shelf.  
WARNING  
Risk of personal injury  
It requires three people to lift the 8010co chassis. To  
make the chassis lighter, remove the modules and  
power supplies before you lift it.  
8
9
Hold the 8010co chassis in position and align the flanged end of  
the chassis mounting rail with the six holes on each side of the  
vertical rack support.  
Make sure the hole pairs on each side of the vertical support  
match horizontally.  
Tighten each screw using a Phillips-head screwdriver.  
--End--  
Installing the 8003, 8006, and 8010 chassis cable guides  
Install the 8003, 8006, and 8010 chassis cable guides to fasten the cable  
clusters and keep them out of the way.  
ATTENTION  
Ensure the cable clusters are accessible for maintenance.  
Procedure steps  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
38 Installation  
Step  
1
Action  
Loosen, but do not remove, the rack-mounting screws required  
to install a cable guide.  
2
Slide the cable guide onto the loosened screws.  
3
Tighten the screws to secure the cable guide to the chassis.  
--End--  
Installing the top cable-management bracket  
Install the top cable-management bracket to the 8010co chassis.  
Procedure steps  
Step  
1
Action  
Align the mounting retainers on the inside of the top  
cable-management bracket with the holes on the front of the  
chassis.  
2
3
Push the sides of the top cable-management bracket into place.  
Insert and tighten the eight screws using a Phillips screwdriver to  
secure the top cable-management bracket to the chassis.  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing the side cable-management brackets 39  
Procedure job aid: Installing the cable-management brackets  
Installing the side cable-management brackets  
Install the side cable-management brackets to each side of the 8010co  
chassis.  
Procedure steps  
Step  
1
Action  
Align the slots on the side cable-management bracket with the  
rods in the chassis.  
2
Push the bracket into place.  
For more information, see “Procedure job aid: Installing the  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
40 Installation  
Grounding the 8010co chassis  
Ground the 8010co chassis to avoid electrical hazard and ensure optimal  
performance.  
ATTENTION  
Nortel recommends grounding the 8010co chassis before you connect power  
cables or network cables to your switch.  
Prerequisites  
Verify that you have the following tools and materials:  
One single-hole cable lug that fits over one of the grounding studs.  
A nut and locking washer for the grounding stud  
A 6-AWG grounding wire long enough to connect to the ground  
point  
A 7/16-inch hex wrench to fasten the hardware in the correct order  
Procedure steps  
Step  
1
Action  
Locate the shelf grounding point on the rack.  
The rack grounding point is a grounding strip located on the  
back, base, top, or side.  
ATTENTION  
The rack grounding strip can look different than the one shown in  
procedure job aid.  
2
Attach the lug ends of the chassis ground cables to the rack  
grounding strip using a 7/16-inch hex wrench to fasten the  
hardware in the correct order.  
For more information, see “Procedure job aid: Grounding the  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing a module 41  
Procedure job aid: Grounding the 8010co chassis  
Figure 1  
Location of ground studs on a 8010co chassis rear panel  
Installing a module  
Install Ethernet Routing Switch 8600 modules to provide communications  
interfaces for switching and routing operations.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
42 Installation  
ATTENTION  
You can install an Ethernet Routing Switch 8600 module with the power on or  
off.  
Procedure steps  
Step  
Action  
1
2
Locate the slot where you want to install the module.  
Remove the power filler panel.  
3
4
5
6
Extend the insert and extract levers away from the front of the  
module.  
Slide the module into the slot, using the module guides, until the  
connector panel touches the chassis back panel.  
Rotate the insert and extract levers to seat the module  
backplane connectors.  
Tighten the two captive screws to secure the module to the  
chassis using a Phillips screwdriver.  
installing a module in various chassis.  
7
After you install the modules, you can connect console  
equipment and network cables.  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Installing AC power modules 43  
Procedure job aid: Installing a module  
Figure 2  
Installing a module in a 8010co chassis  
Figure 3  
Installing a module in a 8003, 8006, and 8010 chassis  
Installing AC power modules  
Install AC power modules in the left-most bay to supply AC power to the  
chassis.  
ATTENTION  
The 8006, 8010, and 8010co chassis have three power supply bays that are  
numbered 1, 2, and 3 from left to right as viewed from the front of the chassis.  
The 8003 chassis has 2 power supply bays that are numbered 1 and 2 from left  
to right.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
44 Installation  
Prerequisites  
Ensure the filler panel or cover from the power bay is removed. To remove  
Procedure steps  
Step  
1
Action  
Grasp the handle of the new power supply and push the power  
supply firmly into the bay.  
2
Tighten the retaining screws until the power supply is firmly  
seated.  
3
Connect the power cord to the power supply and to an AC power  
outlet that is connected to a circuit with no other equipment  
connections.  
--End--  
Installing DC power modules  
Install the DC power supply module in the leftmost bay to supply DC power  
to the chassis.  
ATTENTION  
The 8006 and 8010 chassis have three power supply bays that are numbered 1,  
2, and 3 from left to right as viewed from the front of the chassis.  
Prerequisites  
Verify that you have the following tools and materials:  
Cable  
Crimping tool for crimping the lugs onto the cable  
Heat gun to shrink the tubing around the cable (optional)  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing DC power modules 45  
A 7/16-inch hex wrench  
Phillips screwdriver  
Ensure the filler panel or cover is removed from the power bay. To  
remove the filler panel, see “Removing a power filler panel” (page 33).  
ATTENTION  
Nortel does not supply the cables for connecting the DC power supply to the DC  
input power source. Select cables that comply with the electrical code of the  
country where you use the DC power supply.  
Procedure steps  
Step  
Action  
1
2
Make sure that the power switch is turned off.  
Grasp the handle of the new power supply and push it partway  
into the bay, leaving the terminal block at the side of the power  
supply exposed.  
3
Remove the screw that secures the plastic safety cover to the  
power supply using a Phillips screwdriver.  
4
5
Remove the cover and set it aside.  
Record the positions of the ground stud and of the positive and  
negative power inputs.  
ATTENTION  
Make sure the +DC cable is always connected to the positive terminal  
and that the -DC cable is always connected to the negative terminal.  
DANGER  
Risk of injury by electric shock  
Make sure that the DC power source is off by  
switching off the circuit breaker or disconnecting at  
the remote end before you connect the terminal leads  
to the power supply.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
46 Installation  
6
Attach the earth ground lead to the ground stud on the power  
supply. Use the washers in the following order:  
flat washer  
crimp lug  
lock washer  
hex nut  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Installing DC power modules 47  
7
Attach the positive voltage lead to the positive terminal on the  
power supply, inserting a lock washer between the crimp lug and  
each hex nut.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
48 Installation  
8
Attach the negative voltage lead to the negative terminal on the  
power supply, inserting a lock washer between the crimp lug and  
each hex nut.  
9
Tighten the hex nut using a 7/16 in. hex wrench on each  
terminal.  
10  
11  
Attach the earth ground cable to the system or rack ground for  
the DC input power source.  
Attach the positive and negative terminal leads to the DC input  
power source according to the safety and technical specifications  
for your 48 V power distribution system.  
12  
Replace the plastic safety cover on the power supply using a  
Phillips screwdriver.  
13  
14  
Firmly slide the power supply all the way into the bay.  
Tighten the retaining screws until the power supply is firmly  
seated.  
15  
16  
Turn the DC input power source on, or reset the power source  
circuit breaker, to provide power to the power supply.  
Turn the power supply switch to the on position.  
ATTENTION  
If the chassis contains two or three non-redundant power supplies,  
turn on the power supplies simultaneously. If you wait longer to turn  
on the second power supply, one of the power supplies can turn  
off within 7 seconds. To correct this condition, turn off the power  
supplies for a short period of time and then simultaneously turn them  
on.  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Starting the system 49  
Cable preparation  
Prepare cables for connecting the DC power supply.  
Procedure steps  
Step  
Action  
1
2
Strip 0.81 in. (2.1 cm) of insulation from the ends of the cables.  
Crimp the lugs onto the cables using a standard crimping tool.  
WARNING  
Failure to properly crimp the lugs onto the cables  
constitutes a safety hazard.  
3
If necessary, use a heat gun to shrink the tubing around the  
cable.  
--End--  
Installing a breaker interface panel  
For more information on installing a breaker interface panel (BIP),  
see Installing the Breaker Interface Panel for the 8010co Chassis ,  
(NN46205-313).  
Installing a PCMCIA software card  
Insert the PCMCIA card into the PCMCIA slot of the CPU.  
Starting the system  
Start the system to run a set of internal self-diagnostic tests for all  
modules.  
Starting the system navigation  
Turning on AC power supplies  
Turn on an Ethernet Routing Switch 8000 Series chassis with an AC  
power supply.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
         
50 Installation  
Procedure steps  
Step  
Action  
1
2
Verify the AC power cords are connected to AC power outlets.  
Turn each AC power supply switch to the on position  
simultaneously. Do not operate the 8010co chassis with only one  
power supply.  
ATTENTION  
If the chassis contains two or three power supplies, turn on the  
power supplies simultaneously. If you wait longer to turn on the  
second power supply, one of the power supplies can turn off within 7  
seconds. To correct this condition, turn off the power supplies for a  
short period of time and then simultaneously turn them on.  
3
4
Verify that the power LED on each power supply turns green.  
Verify that the power supply status LEDs and the fan LED on the  
8691SF/CPU or 8692SF/CPU modules turn green.  
5
Verify that air flows from the cooling fans through the chassis  
vents.  
ATTENTION  
The red fan tray fail LED may light briefly while the fans power to  
operational speed.  
--End--  
Turning on DC power supplies  
Step  
1
Action  
Turn the power switch on each DC power supply to the on  
position. It is not necessary to remove the bezel to turn the  
switch on.  
ATTENTION  
If the chassis contains two or three power supplies, turn on the  
power supplies simultaneously. If you wait longer to turn on the  
second power supply, one of the power supplies can turn off within 7  
seconds. To correct this condition, turn off the power supplies for a  
short period of time and then simultaneously turn them on.  
2
3
Verify that the power output LED for each power supply turns  
green.  
Verify that the power supply status LEDs and the fan LED on the  
8691SF/CPU or 8692SF/CPU modules turn green.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Verifying a successful installation 51  
ATTENTION  
The red fan tray fail LED may light briefly while the fans power to  
operational speed.  
--End--  
LED power supply  
After you turn on the Ethernet Routing Switch 8000 Series, each module  
automatically initiates a diagnostic test to verify proper module function.  
If the power supply LED remains off, do the following:  
Procedure steps  
Step  
Action  
1
2
3
Turn the power switch on each power supply to the off position.  
Wait 1 minute.  
Turn the power switch on each power supply to the on position.  
--End--  
Verifying a successful installation  
The following list describes a successful starting sequence for an  
Ethernet Routing Switch.  
When power is applied to the Ethernet Routing Switch 8000, the  
green LED on each power supply and fan tray or cooling module  
turns on, and the Online LED for each module is amber.  
Each module initiates a self-test, during which time the port and  
module LEDs display various patterns to indicate the progress of  
the self-test.  
Upon successful completion of the self-test (within 2 or 3 minutes  
after power is applied to a fully loaded chassis), the module Online  
LED transitions from amber to green.  
After 1 minute of operation, the fan tray Pass LED lights remain  
green.  
If the LEDs on the modules light in this sequence, your installation  
is successful. Contact your network administrator to verify that the  
Ethernet Routing Switch 8000 is connected to the network.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
52 Installation  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
53  
.
Configuration  
This chapter contains configuration instructions for Ethernet Routing  
Switch 8600.  
Navigation  
Connecting a modem using the CLI  
This section describes how to connect a modem to the modem port on  
a module. You can access the CLI through a modem connection to the  
Ethernet Routing Switch 8690SF, 8691SF/CPU, or 8692SF/CPU modules.  
The modem port is a DTE device is operating at:  
9600 baud rate  
8 data bits  
no parity  
one stop bit  
ATTENTION  
Nortel recommends to use the default settings for the Modem port for most  
modem installations.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
54 Configuration  
Because the modem port will receive Data Set Ready (DSR) and Clear To  
Send (CTS) signals before transmitting, the DSR and CTS control lines are  
required in the cables. The modem port does not support inbound flow  
control; therefore, the port does not turn on and off control lines to indicate  
that the input buffer is full.  
Before connecting a modem to an Ethernet Routing Switch you may need  
to configure the modem port using another type of CLI connection.  
To configure the modem port using the Ethernet Routing Switch CLI,  
complete the steps in the following procedure.  
Prerequisites  
You need a DTE-to-DCE cable (straight or transmit cable) to connect  
the Nortel Ethernet Routing Switch 8600 to the modem.  
You must configure your client dial-up settings to establish the  
connection to the modem.  
Procedure steps  
Step  
1
Action  
Configure the modem using the following command:  
config bootconfig sio modem  
Now you can enter options for this command level without  
retyping the first part of the command.  
2
Configure port parameters based on the modem requirements:  
baud <rate>  
8databits <true|false>  
mode <ascii|slip|ppp>  
For information about the configuration requirements of your  
modem, see the documentation shipped with the modem.  
ATTENTION  
Nortel recommends that before you configure SLIP or PPP modes,  
you become familiar with these protocols.  
3
If you assign the port mode to slip, configure the following  
parameters:  
slip-compression <true|false>  
slip-rx-compression <true|false>  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Connecting a modem using the CLI 55  
4
If you assign the port mode to ppp, configure the following  
parameters:  
mtu <bytes>  
my-ip <ipaddr>  
peer-ip <ipaddr>  
pppfile <file>  
5
6
7
8
Turn off echo mode and return code messaging on the modem.  
Connect the modem to the modem port.  
Save the boot configuration.  
Reboot the switch.  
--End--  
Variable definitions  
Variable  
Value  
Specifies either 8 (true) or 7 (false) data bits  
for each byte for software to interpret. The  
default is false.  
8databits <true|false>  
baud<rate>  
Sets the baud rate for the modem. The  
default is 9600.  
True sets the value to 7.  
False sets the value to 8. This setting is  
default.  
enable <true|false>  
ascii  
Sets the default setting.  
This setting is recommended for most  
modem connections.  
slip  
ppp  
Sets the port for serial line IP (SLIP)  
operation.  
Sets the port for point-to-point protocol  
(PPP) operation.  
slip-compression  
<true|false>  
Enables or disables the TCP/IP header  
compression. The default is false.  
slip-rx-compression  
<true|false>  
Enables or disables the TCP/IP header  
compression on the receive packet. The  
default is false.  
mtu <bytes>  
Sets the maximum transmission unit for the  
point-to-point link (0–2048). The default is  
zero (0).  
my-ip <ipaddr>  
Sets the near-end IP address on the  
point-to-point link. The default is 0.0.0.0.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
56 Configuration  
Variable  
Value  
peer-ip <ipaddr>  
Sets the peer IP address on the  
point-to-point link. The default is 0.0.0.0.  
pppfile <file>  
Identifies the file to use for PPP initialization  
parameters.  
Procedure job aid: DTE-to-DCE straight-through pin assignments  
Table 3  
DTE-to-DCE straight-through pin assignments  
Switch  
Modem  
Signal  
Pin  
number  
DCE DB-9  
pin number  
DCE DB-25  
pin number  
2
3
4
5
6
7
8
2
3
4
5
6
7
8
3
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
CTS  
2
20  
7
6
4
5
Connecting a modem using the NNCLI  
Connect a modem to a Ethernet Routing Switch 8600 to establish a  
connection with the switch. To connect a modem to an Ethernet Routing  
Switch you may need to set up the modem port using another type of  
connection, such as a terminal connection, to the NNCLI.  
You can access the NNCLI through a modem connection to the Ethernet  
Routing Switch 8690SF, 8691SF/CPU, or 8692SF/CPU modules.  
ATTENTION  
Nortel recommends that you use the default settings for the modem port for  
most modem installations.  
Prerequisites  
You need a DTE-to-DCE cable (straight or transmit cable) to connect  
the Nortel Ethernet Routing Switch 8600 to the modem.  
You must configure your client dial-up settings to establish the  
connection to the modem.  
You must log on to the Global Configuration mode in the NNCLI.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Connecting a modem using the NNCLI 57  
Procedure steps  
Step  
1
Action  
Configure port parameters based on the requirements of the  
modem by using the following command:  
boot config sio modem  
For information about the configuration requirements of your  
modem, see the documentation shipped with the modem.  
ATTENTION  
Nortel recommends that before you configure Serial Line IP (SLIP) or  
PPP, you become familiar with these protocols.  
2
3
If you assign the port mode to slip, use the following command  
to configure other slip parameters:  
boot config sio modem [slip-compression]  
[slip-rx-compression]  
If you assign the port mode to ppp, use the following commands  
to configure other ppp parameters:  
boot config sio modem [mtu <bytes>] [my-ip  
<ipaddr>] [peer-ip <ipaddr>] [pppfile <file>]  
4
5
6
7
Turn off echo mode and return code messaging on the modem.  
Connect the modem to the modem port.  
Save the boot configuration.  
Optionally, shutdown and reinitialize the port by using the  
following command:  
boot config sio modem restart  
8
Reboot the switch.  
--End--  
Variable definitions  
Variable  
Value  
8databits  
Set number of data bits per byte for  
software to interpret.  
baud  
mode  
mtu  
Set baud rate for the modem.  
Set serial port mode.  
Sets point-to-point link maximum  
transmission unit.  
my-ip  
Sets my IP address on point-to-point link.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
58 Configuration  
Variable  
peer-ip  
pppfile  
Value  
Set peer IP address on point-to-point link.  
Use the file for PPP initialization  
parameters.  
restart  
Shutdown and re-initialize the port.  
Enable TCP/IP header compression.  
slip-compression  
slip-rx-compression  
Enable receive packet TCP/IP header  
compression.  
my-ip  
Sets my IP address on point-to-point link.  
Procedure job aid: DTE-to-DCE straight-through pin assignments  
Table 4  
DTE-to-DCE straight-through pin assignments  
Switch  
Modem  
Signal  
Pin  
number  
DCE DB-9  
pin number  
DCE DB-25  
pin number  
2
3
4
5
6
7
8
2
3
4
5
6
7
8
3
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
CTS  
2
20  
7
6
4
5
Connecting a VT-100 terminal or PC for local access  
Connect a VT-100 terminal or a personal computer to the console port on  
a 8691SF/CPU or 8692SF/CPU module to establish a local CLI, NNCLI  
or Device Manager session.  
Prerequisites  
A serial console cable with a nine-pin receptable connector.  
Procedure steps  
Step  
1
Action  
Connect an RS-232 cable to the console port on an  
8691SF/CPU or 8692SF/CPU module.  
2
Connect the other end of the RS-232 cable to a VT-100 terminal  
or PC serial port.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Setting system date and time using the NNCLI 59  
3
4
Turn on the terminal or PC.  
Log on to the CLI.  
--End--  
Setting system date and time using the CLI  
Set the system date and time using the CLI.  
Procedure steps  
Action  
Set the date of the system by using the following command:  
config setdate <MMddyyyyhhmmss>  
Procedure job aid: config setdate command sample output  
The following is a sample output to verify the config setdate command.  
Setting system date and time using the NNCLI  
Set the system date and time using the NNCLI.  
Prerequisites  
You must log on to the privExec mode.  
Procedure steps  
Action  
Set the system date by using the following command:  
clock set <MMddyyyyhhmmss>  
Procedure job aid: clock set command output  
The following is a sample output to verify the clock set command .  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
       
60 Configuration  
Changing passwords using the CLI  
Set new passwords for each access level, or change the logon password  
for the different switch access.  
The Ethernet Routing Switch Switch 8600 ships with default passwords  
configured for CLI access. When you use Simple Network Management  
Protocol version 3 (SNMPv3), you can change passwords that are in an  
encrypted format.  
Prerequisites  
You must have read-write-all privileges to change passwords.  
Passwords are saved to a hidden file to maintain security. The  
password associated with the user name or logon name is the optional  
password parameter.  
Procedure steps  
Action  
Change a password by using the following command:  
config cli password  
Variable definitions  
Use the data in the following table to use the config cli password  
command.  
Variable  
Value  
access level <access level>  
<enable|disable>  
Allows or blocks this access level.  
access level is an integer from  
2 to 8.  
enable|disable enables or  
disables the chosen access level.  
aging <days>  
Sets the password age-out time.  
days is the number of days until  
the password expires from 1 to  
365.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Changing passwords using the CLI 61  
default-lockout-time <secs>  
Changes the default lockout time after  
three invalid attempts.  
secs is the lockout time in seconds  
from 60 to 6500. The default is 60  
seconds.  
info  
Shows the current level parameter  
settings and the next level directories.  
l1 <username> [ <password> ]  
Changes the Layer 1 read and write  
logon name or password or both.  
username is the logon name  
password is the password  
associated with the logon name.  
l2 <username> [ <password> ]  
l3 <username> [ <password> ]  
Changes the Layer 2 read and write  
logon name or password or both.  
username is the logon name.  
password is the password  
associated with the logon name.  
Changes the Layer 3 read and write  
logon name or password or both  
(applies only to the Ethernet Routing  
Switch 8600).  
username is the logon name.  
password is the password  
associated with the logon name.  
l4admin <username>  
l4oper <username>  
Sets the Layer 4 Administrator logon  
to connect to the WSM.1  
Sets the Layer 4 Operator logon to  
connect to the WSM.1  
lockout-time <HostAddress>  
<secs>  
Sets the Host lockout time.  
HostAddress is the Host IP  
address in the format a.b.c.d.  
secs is the lockout-out time in  
seconds for passwords from 60 to  
65000. The default is 60 seconds.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
62 Configuration  
min-passwd-len <integer>  
Sets the minimum length for  
passwords in high-secure mode.  
integer is a range from a  
minimum of 10 to 20.  
oper <username>  
Sets the Operator logon to connect to  
the WSM.1  
password-history <number>  
Specifies the number of previous  
passwords to remember.  
number uses a configurable range  
of 3 to 32.  
The default is 3.  
ro <username> [ <password> ]  
rw <username> [ <password> ]  
rwa <username> [ <password> ]  
slboper <username>  
Changes the read-only logon and/or  
password.  
username is the logon name.  
password is the password  
associated with the logon name.  
Changes the read and write logon  
name or password or both.  
username is the logon name.  
password is the password  
associated with the logon name.  
Changes the read and write all logon  
name or password or both.  
username is the logon name.  
password is the password  
associated with the logon name.  
Sets the server load balancing (SLB)  
Operator login to connect to the Web  
Switch Module (WSM).1  
slbadmin <username>  
ssladmin <username>  
Sets the SLB Administrator logon to  
connect to the WSM.1  
Sets the ssladmin logon to connect to  
and configure the SSL acceleration  
module (SAM).  
1 For more information about the WSM, see Nortel Ethernet Routing Switch  
8600 Web Switching Module Fundamentals, (NN46205-314).  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Changing passwords using the NNCLI 63  
Changing passwords using the NNCLI  
Set new passwords for each access level, or change the logon or  
password for various access levels of the switch.  
The Ethernet Routing Switch 8600 ships with default passwords set for  
access to the NNCLI. When using Simple Network Management Protocol  
version 3 (SNMPv3), you can change passwords that are in encrypted  
format.  
Prerequisites  
You must have read-write-all privileges to change passwords. For  
security, passwords are saved to a hidden file.  
You must log on to the global configuration mode.  
Procedure steps  
Step  
1
Action  
Change a password by using the following command:  
cli password <word> <access-level>  
2
Configure password options by using the following command:  
password aging-time [day <1-365>] [default-lockout-time  
<60-65 000>] [min-passwd-len <10-20>] [password-history  
<3-32>]  
--End--  
Variable definition  
Use the data in the following table to use the password commands.  
Variable  
Value  
access level  
Allows or blocks this access level. The  
available access levels are:  
l4admin 1  
l4oper1  
layer1 <word>  
layer2  
layer3 <word>  
oper1  
read-only <word>  
read-write <word>  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
64 Configuration  
read-write-all <word>  
slbadmin1  
slboper1  
ssladmin  
<word> represents the new password  
with 0 to 20 characters.  
aging-time <1-365>  
Sets the age-out time for passwords,  
in days.  
default-lockout-time <60-65  
000>  
Changes the default lockout time after  
three invalid attempts. Sets the lockout  
time in seconds and is in the range  
of 60 to 65 000. The default is 60  
seconds.  
To set this option to the default value,  
use the default operator with the  
command.  
lockout <WORD 0-64> time  
<60-65000>  
Sets the Host lockout time.  
word is the Host Internet Protocol  
(IP) address in the format a.b.c.d.  
time is the lockout-out time in  
seconds for passwords from 60 to  
65 000. The default is 60 seconds.  
min-passwd-len <10-20>  
password-history <3-32>  
Sets the minimum length for  
passwords in high-secure mode.  
To set this option to the default value,  
use the default operator with the  
command.  
Specifies the number of previous  
passwords to remember. The default  
is 3.  
To set this option to the default value,  
use the default operator with the  
command.  
1 For more information about the WSM, see Nortel Ethernet Routing Switch  
8600 Web Switching Module Fundamentals, (NN46205-314).  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Configuring the system using the setup utility 65  
Configuring the system using the setup utility  
Use the setup utility for the initial configuration of the switch. The setup  
utility uses a series of questions to guide you through the configuration  
process.  
ATTENTION  
Answer each question, or accept the default by pressing Enter. Each question  
includes the default value in brackets and the acceptable parameter options in  
parenthesis.  
Procedure steps  
Step  
Action  
1
2
Power up the system.  
Connect through the console and logon as a default user using  
the following command:  
install  
ATTENTION  
You must connect to the master CPU to use the install script.After  
running the setup utility, remember to reboot the switch.  
A Welcome to the Ethernet Routing Switch 8000 Setup Utility  
message appears stating you are starting initial configuration of  
the switch. The data is stored in the /flash/boot.cfg and runtime  
configuration flash/config.config files.  
3
4
If you want to continue, type  
y.  
Follow the setup utility prompts.  
66).  
5
Restart the switch.  
ATTENTION  
You can use a default password to log on if the switch reboots  
without any previously configured password, and the high secure  
(hsecure) mode is enabled. however, you will be prompted to change  
the password  
For more information about the secure mode, see Security,  
NN46205-601.  
--End--  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
66 Configuration  
Procedure job aid: Setup Utility prompt descriptions  
Prompt  
Action  
Please provide primary  
config-file path  
[/flash/config.cfg]:  
Press Enter to accept the default (/flash/config.cfg),  
or enter a different file location for the primary  
configuration file. To store the configuration file  
on the PCMCIA card, use /pcmcia/config.cfg.  
Specifying the path to the file is optional.  
Please provide  
primary image-file path  
[flash/p80a41xx.img]:  
Press Enter to accept the default (/flash/p80a4  
1xx.img), or enter a different file location for the  
primary image file. Specifying the path to the  
file is optional. If the runtime image resides on  
a PCMCIA card, you must specify the path (for  
example /pcmcia/filename).  
Please add system  
prompt [Ethernet Routing  
Switch-8606]:  
Press Enter to accept the default (Ethernet Routing  
Switch-8606), or enter a different string of up to 20  
characters.  
Press Enter to accept the default (5), or specify 6  
for the master CPU slot.  
Please select CPU  
Master slot (5/6) [5]:  
Master CPU mgmt port:  
autonegotiation [n] (y/n)?  
Press Enter to accept the default(n), or enter  
y to indicate that you want the master CPU  
management port to use autonegotiation.  
speed (10/100) [10]:  
Press Enter to accept the default (10 Mbps), or  
specify 100 Mbps.  
Do you want to enable  
automatic savetostandby  
mode [n] (y/n)?  
Press Enter y if you want the boot and runtime  
configuration files to be saved on the backup  
CPU.Press Enter to accept the default (n), if you  
want the boot and runtime configuration files to be  
saved only on the primary CPU.  
Do you want to enable  
m-mode support [n] (y/n)?  
Press Enter y if you want the chassis to run in 128  
K or M mode. Press Enter to accept the default  
(n), if you want it to run in 32 K mode only.  
To run in 128 K mode, the CPU module must be  
an 8691 or higher and the switch must have at  
least one 8600 module (128 K module).  
If you enable m-mode support and you have a  
mixed configuration of modules, the E-modules  
and classic modules are disabled.  
Do you want to enable  
enhanced operation mode  
support [n] (y/n)?  
Enter y if you want to enable enhanced operation  
mode. Accept the default (n), if you do not want to  
enable enhanced operation mode. If you enable  
enhanced operation mode and you have a mixed  
configuration of modules, the classic modules (E-  
or M-modules) are disabled.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Configuring the system using the setup utility 67  
Prompt  
Action  
Do you want to enable  
CPU High Availability  
mode [n] (y/n)?  
Specify y if you want to enable CPU high  
availability (HA) mode. Accept the default (n), if  
you do not want to enable CPU HA mode.  
Do you want to enable  
vlan-optimization-mode  
support [n] (y/n) ?  
Specify y if you want to enable vlan-optimization-  
mode support. Accept the default (n) if you do not  
want to enable vlan-optimization-mode support.  
Do you want to enable  
Specify y if you want to enable r-mode support.  
r-mode support [n] (y/n) ? Accept the default (n) if you do not want to enable  
r-mode support.  
Do you want to enable  
FTP [n] (y/n)?  
Enter y if you want to enable FTP for remote  
users. Accept the default (n), if you do not want to  
enable FTP.  
Do you want to enable  
RLOGIN [n] (y/n)?  
Enter y if you want to enable Rlogin for remote  
users. Press Enter to accept the default (n), if you  
do not want to enable Rlogin.  
Do you want to enable  
TELNET [n] (y/n)?  
Enter y if you want to enable Telnet. Press Enter  
to accept the default (n), if you do not want to  
enable Telnet.  
Do you want to enable  
TFTP [n] (y/n)?  
Enter y if you want to enable TFTP. Press Enter to  
accept the default (n), if you do not want to enable  
TFTP.  
Do you want to enable  
WEB server service [n]  
(y/n)?  
Enter y if you want to enable WEB server service.  
Press Enter to accept the default (n), if you do not  
want to enable WEB server service.  
IP Address for mgmt port  
Enter the IP address of the management port in  
in first CPU Slot [192.168. the first CPU slot.  
168.168/255.255.255.0]:  
IP Address for mgmt  
port in second CPU Slot  
[192.168.168.169/255.255  
.255.0]:  
Enter the IP address of the management port in  
the second CPU slot.  
IP Address for  
mgmt-virtual-ip  
[0.0.0.0/0.0.0.0]:  
Enter the IP address of the virtual management  
port. Press Enter to accept the default  
(0.0.0.0/0.0.0.0) if you do not want to specify  
an IP address.  
First net mgmt route  
[0.0.0.0:0.0.0.0]:  
Enter the IP address of the first network  
management route.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
68 Configuration  
Prompt  
Action  
Second net mgmt route  
[0.0.0.0:0.0.0.0]:  
Enter the IP address of the second network  
management route (static route from the network  
management port to a device in the network).  
For security reasons, the system does not accept  
a route to a network that conflicts with the main  
nonmanagement routing table, and, therefore,  
does not accept a default route of 0.0.0.0.  
Third net mgmt route  
[0.0.0.0:0.0.0.0]:  
Enter the IP address of the third network  
management route (static route from the network  
management port to a device in the network).  
Fourth net mgmt route  
[0.0.0.0:0.0.0.0]:  
Enter an IP address of the fourth network  
management route (static route from the network  
management port to a device in the network).  
IP address of the default  
VLAN  
Enter the IP address of the default virtual LAN  
(VLAN).  
[0.0.0.0/0.0.0.0]:  
Enter y to save the boot and runtime configuration  
files. Press Enter n if you do not want to save your  
changes.  
Do you want to save the  
changes  
[Saving the parameters  
will update the files  
/flash/boot.cfg and  
/flash/config.cfg] (y/n)?  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
69  
.
Translation of safety messages  
Fan tray safety warning message  
WARNING  
Risk of personal injury  
Grasp the fan tray at the middle of the front panel, and be  
careful to keep your fingers out of the fan blades.  
WARNING  
AVERTISSEMENT  
Risques de blessure corporelle  
Saisissez le boîtier du ventilateur au milieu du panneau avant  
en veillant à maintenir vos doigts éloignés des pales.  
WARNING  
WARNUNG  
Verletzungsrisiko  
Greifen Sie das Gehäuse des Lüfters vorne in der Mitte, und  
achten Sie darauf, dass Ihre Finger nicht zwischen die Blätter  
des Lüfters geraten.  
WARNING  
ADVERTENCIA  
Riesgo de lesiones  
Sostenga la bandeja del ventilador en la mitad del panel  
delantero y tenga cuidado de mantener los dedos alejados de  
las aspas.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
70 Translation of safety messages  
WARNING  
AVISO  
Risco de ferimento  
Segure a bandeja do ventilador no meio do painel frontal e  
tenha cuidado para não colocar os dedos nas lâminas do  
ventilador.  
WARNING  
AVVISO  
Rischio di lesioni personali  
Afferrare il vassoio del ventilatore nella parte centrale del  
pannello frontale e prestare attenzione a non toccare le lame.  
Preventing back injury warning statement  
WARNING  
Risk of personal injury  
It requires two people to lift a fully-loaded chassis. To prevent  
injury, keep your back straight and lift with your legs. An  
Ethernet Routing Switch 8010 chassis weighs approximately  
101 kg (225 lbs). An Ethernet Routing Switch 8006 chassis  
weighs approximately 77 kg (170 lbs). An Ethernet Routing  
Switch 8003 chassis weighs approximately 49.5 kg (110 lbs).  
WARNING  
AVERTISSEMENT  
Risques de blessure corporelle  
Deux personnes sont nécessaires pour soulever un châssis  
rempli. Pour éviter tout risque de blessure, gardez le dos droit  
et utilisez l’appui de vos jambes pour soulever la charge. Le  
châssis d’un commutateur-routeur Ethernet 8010 pèse environ  
101 kg. Le châssis d’un commutateur-routeur Ethernet 8006  
pèse environ 77 kg. Le châssis d’un commutateur-routeur  
Ethernet 8003 pèse environ 49,5 kg.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Preventing back injury warning statement 71  
WARNING  
WARNUNG  
Verletzungsrisiko  
Es sind 2 Personen notwendig, um ein voll besetztes Chassis  
anzuheben. Zur Vermeidung von Verletzungen halten Sie  
beim Heben Ihren Rücken gerade, und heben Sie das Gewicht  
aus den Beinen heraus. Das Chassis des Ethernet Routing  
Switch 8010 wiegt ungefähr 101 kg (225 lbs). Das Chassis des  
Ethernet Routing Switch 8006 wiegt ungefähr 77 kg (170 lbs).  
Das Chassis des Ethernet Routing Switch 8003 wiegt ungefähr  
49,5 kg (110 lbs).  
WARNING  
ADVERTENCIA  
Riesgo de lesiones  
Se necesitan dos personas para levantar un chasis  
completamente cargado. Para evitar lesiones, mantenga la  
espalda recta y realice la fuerza con las piernas. El chasis de  
Ethernet Routing Switch 8010 pesa aproximadamente 101  
kg (225 lb). El chasis de Ethernet Routing Switch 8006 pesa  
aproximadamente 77 kg (170 lb). El chasis de Ethernet Routing  
Switch 8003 pesa aproximadamente 49,5 kg (110 lb).  
WARNING  
AVISO  
Risco de ferimento  
Para erguer um chassi totalmente carregado, são necessárias  
duas pessoas. Para evitar ferimentos, mantenha sua coluna  
reta e erga suas pernas. Um chassi Ethernet Routing Switch  
8010 pesa aproximadamente 101 kg (225 lbs). Um chassi  
Ethernet Routing Switch 8006 pesa aproximadamente 77  
kg (170 lbs). Um chassi Ethernet Routing Switch 8003 pesa  
aproximadamente 49,5 kg (110 lbs).  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
72 Translation of safety messages  
WARNING  
AVVISO  
Rischio di lesioni personali  
Sono necessarie due persone per sollevare uno chassis a  
pieno carico. Per evitare lesioni, mantenere la schiena dritta e  
sollevarsi con le gambe. Uno chassis Ethernet Routing Switch  
8010 pesa circa 101 kg (225 libbre). Uno chassis Ethernet  
Routing Switch 8006 pesa circa 77 kg (170 libbre). Uno chassis  
Ethernet Routing Switch 8003 pesa circa 49,5 kg (110 libbre).  
Preventing electrical shock warning statement  
WARNING  
Risk of injury by electric shock  
To avoid the danger of electrical shock, be careful when working  
with power equipment and connections.  
WARNING  
AVERTISSEMENT  
Risques de blessure par choc électrique  
Pour prévenir les risques de choc électrique, soyez vigilants  
lorsque vous manipulez des équipements et des connexions  
électriques.  
WARNING  
WARNUNG  
Verletzungsrisiko durch  
Stromschlag Zur Vermeidung eines Stromschlages gehen Sie  
beim Umgang mit stromführenden Geräten und Anschlüssen  
sorgfältig vor.  
WARNING  
ADVERTENCIA  
Riesgo de lesiones por choques eléctricos  
Para evitar choques eléctricos, maneje los equipos y  
conexiones eléctricas con cuidado.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Preventing hand injury warning statement 73  
WARNING  
AVISO  
Risco de ferimento por choque elétrico  
Para evitar o perigo do choque elétrico, tenha cuidado ao  
trabalhar com equipamentos e conexões elétricos.  
WARNING  
AVVISO  
Rischio di lesioni per shock elettrico  
Per evitare il pericolo di shock elettrico, prestare attenzione  
quando si lavora con l’alimentatore e i collegamenti.  
Preventing hand injury warning statement  
WARNING  
Risk of injury by fan blades  
When removing the fan module, do not put your hands into the  
opening because of the spinning fan blades in the adjacent fan  
modules.  
WARNING  
AVERTISSEMENT  
Risques de blessure provoquée par les pales du ventilateur  
Lorsque vous retirez le module du ventilateur, ne mettez pas  
vos mains dans l’ouverture car les pales des modules adjacents  
en fonctionnement risqueraient de vous blesser.  
WARNING  
WARNUNG  
Verletzungsrisiko durch Lüfter-Blätter  
Greifen Sie beim Entfernen des Lüftungsmoduls, wegen der  
rotierenden Blätter des sich in der Nähe befindlichen Lüfters,  
nicht in die Öffnung.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
74 Translation of safety messages  
WARNING  
ADVERTENCIA  
Riesgo de lesiones por las aspas del ventilador  
Cuando deba retirar el módulo del ventilador, no coloque las  
manos en la abertura para evitar accidentes con las aspas de  
los ventiladores adyacentes.  
WARNING  
AVISO  
Risco de ferimento com lâmina do ventilador  
Ao remover o módulo do ventilador, não coloque as mãos  
na abertura porque existem lâminas que giram nos módulos  
adjacentes.  
WARNING  
AVVISO  
Rischio di lesioni causate dalle lame del ventilatore  
Quando si rimuove il modulo del ventilatore, non inserire le mani  
nell’apertura, data la presenza delle lame rotanti del ventilatore  
nei moduli adiacenti.  
Safety danger statement  
DANGER  
Risk of injury by electric shock  
Failure to properly crimp the lugs onto the cables constitutes a  
safety hazard  
DANGER  
DANGER  
Risques de blessure par choc électrique  
Pour votre sécurité, vérifiez que les cosses sont correctement  
serties sur les câbles.  
DANGER  
GEFAHR  
Verletzungsrisiko durch Stromschlag  
Es besteht ein Sicherheitsrisiko, wenn die Anschlussstücke nicht  
ordnungsgemäß auf die Kabel geklemmt werden.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Injury to eye warning statement 75  
DANGER  
PELIGRO  
Riesgo de lesiones por choques eléctricos  
Para evitar riesgos, pliegue correctamente hacia adentro los  
terminales de los cables.  
DANGER  
PERIGO  
Risco de ferimento por choque elétrico  
Enrolar os suportes aos cabos de maneira incorreta implica em  
um risco de segurança.  
WARNING  
PERICOLO  
Rischio di lesioni per shock elettrico  
Il piegamento non corretto delle linguette nei cavi costituisce un  
rischio per la sicurezza.  
Injury to eye warning statement  
WARNING  
Risk of eye injury by laser  
Fiber optic equipment can emit laser or infrared light that can  
injure your eyes. Never look into an optical fiber or connector  
port. Always assume that fiber optic cables are connected to a  
light source.  
WARNING  
AVERTISSEMENT  
Risques de blessure oculaire par lumière laser  
L’équipement de fibres optiques peut émettre une lumière  
laser ou infrarouge nuisible à vos yeux. Ne regardez jamais en  
direction de fibres optiques ou d’un port connecteur. Supposez  
toujours que les câbles de fibres optiques sont connectés à une  
source de lumière.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
76 Translation of safety messages  
WARNING  
WARNUNG  
Risiko einer Augenverletzung durch  
Laser Glasfasergeräte können Laserstrahlen oder ultraviolettes  
Licht aussenden, das Ihre Augen verletzen kann. Schauen Sie  
nie direkt in einen Glasfaserleiter oder Verbindungsanschluss.  
Gehen Sie immer davon aus, dass Glasfaserkabel mit einer  
Lichtquelle verbunden sind.  
WARNING  
ADVERTENCIA  
Riesgo de lesión en los ojos por láser  
El equipo de fibra óptica puede emitir una luz láser o infrarroja  
que dañe sus ojos. Nunca mire un puerto de fibra óptica o  
conector. Siempre asuma que los cables de fibra óptica están  
conectados a una fuente de luz.  
WARNING  
AVISO  
O laser pode causar ferimentos no olho  
O equipamento de fibra ótica pode emitir laser ou luz  
infravermelha que pode causar danos a sua vista. Nunca olhe  
para dentro da fibra ótica ou da porta do conector. Tenha  
sempre em mente que os cabos de fibra ótica estão ligados a  
uma fonte de luz.  
WARNING  
AVVISO  
Rischio di ustioni agli occhi dovute al laser  
Le apparecchiature con fibre ottiche possono emettere raggi  
laser o infrarossi in grado di provocare ferite agli occhi. Non  
guardare mai all’interno di una porta di connessione o una fibra  
ottica. Tenere sempre presente che i cavi a fibra ottica sono  
collegati a una sorgente luminosa.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety practices and the hazards danger statement 77  
Safety practices and the hazards danger statement  
DANGER  
Risk of injury by electric shock  
Before working on this equipment, be aware of proper safety  
practices and the hazards involved with electrical circuits. Use  
only power cords that have a grounding path. Ensure the switch  
is properly grounded before powering on the unit.  
DANGER  
DANGER  
Risques de blessure par choc électrique  
Avant de manipuler cet équipement, vous devez prendre  
connaissance des pratiques de sécurité appropriées et des  
risques associés aux circuits électriques. Utilisez uniquement  
des cordons d’alimentation possédant un conducteur de terre.  
Assurez-vous que le commutateur est correctement relié à la  
terre avant de mettre l’unité sous tension.  
DANGER  
GEFAHR  
Verletzungsrisiko durch  
Stromschlag Informieren Sie sich über entsprechende  
Sicherheitsmaßnahmen und die mit Stromkreisen verbundenen  
Gefahren, bevor Sie mit diesem Gerät arbeiten. Verwenden  
Sie nur Netzkabel mit Erdungspfad. Stellen Sie sicher, dass  
der Schalter ordnungsgemäß geerdet ist, bevor Sie das Gerät  
einschalten.  
DANGER  
PELIGRO  
Riesgo de lesión por electrocución  
Antes de trabajar con este equipo, infórmese acerca de las  
medidas de seguridad adecuadas y de los peligros relacionados  
con los circuitos eléctricos. Utilice sólo cables de corriente que  
tengan puesta a tierra. Asegúrese de que el interruptor tenga  
puesta a tierra antes de encender la unidad.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
78 Translation of safety messages  
DANGER  
PERIGO  
Risco de ferimentos por choque elétrico  
Antes de começar a trabalhar com o equipamento, esteja ciente  
das práticas de segurança adequadas e dos perigos inerentes  
a circuitos elétricos. Use apenas cabos de alimentação que  
tenham ligação à terra. Certifique-se de que o switch esteja  
devidamente aterrado antes de ligar o aparelho.  
DANGER  
PERICOLO  
Rischio di scosse elettriche  
Prima di utilizzare questa apparecchiatura, considerare le  
appropriate pratiche di sicurezza e i pericoli correlati ai circuiti  
elettrici. Utilizzare esclusivamente cavi di alimentazione dotati  
di un percorso per il collegamento a terra. Prima di attivare  
l’alimentazione dell’unità, accertarsi che l’interruttore sia  
adeguatamente collegato alla messa a terra.  
Safety practices and the hazards danger statement  
DANGER  
Risk of injury by electric shock  
Before working on this equipment, be aware of proper safety  
practices and the hazards involved with electrical circuits. Use  
only power cords that have a grounding path. Ensure the switch  
is properly grounded before powering on the unit.  
DANGER  
Risques de blessure par choc électrique  
Avant de manipuler cet équipement, vous devez prendre  
connaissance des pratiques de sécurité appropriées et des  
risques associés aux circuits électriques. Utilisez uniquement  
des cordons d’alimentation possédant un conducteur de terre.  
Assurez-vous que le commutateur est correctement relié à la  
terre avant de mettre l’unité sous tension.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Safety practices and the hazards danger statement 79  
DANGER  
GEFAHR  
Verletzungsrisiko durch Stromschlag  
Informieren Sie sich über entsprechende Sicherheitsmaßnah  
men und die mit Stromkreisen verbundenen Gefahren, bevor  
Sie mit diesem Gerät arbeiten. Verwenden Sie nur Netzkabel  
mit Erdungspfad. Stellen Sie sicher, dass der Schalter  
ordnungsgemäß geerdet ist, bevor Sie das Gerät einschalten.  
DANGER  
PELIGRO  
Riesgo de lesión por electrocución  
Antes de trabajar con este equipo, infórmese acerca de las  
medidas de seguridad adecuadas y de los peligros relacionados  
con los circuitos eléctricos. Utilice sólo cables de corriente que  
tengan puesta a tierra. Asegúrese de que el interruptor tenga  
puesta a tierra antes de encender la unidad.  
DANGER  
PERIGO  
Risco de ferimentos por choque elétrico  
Antes de começar a trabalhar com o equipamento, esteja ciente  
das práticas de segurança adequadas e dos perigos inerentes  
a circuitos elétricos. Use apenas cabos de alimentação que  
tenham ligação à terra. Certifique-se de que o switch esteja  
devidamente aterrado antes de ligar o aparelho.  
DANGER  
PERICOLO  
PERICOLO Rischio di scosse elettriche  
Prima di utilizzare questa apparecchiatura, considerare le  
appropriate pratiche di sicurezza e i pericoli correlati ai circuiti  
elettrici. Utilizzare esclusivamente cavi di alimentazione dotati  
di un percorso per il collegamento a terra. Prima di attivare  
l’alimentazione dell’unità, accertarsi che l’interruttore sia  
adeguatamente collegato alla messa a terra.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
80 Translation of safety messages  
Preventing electric shock danger statement  
DANGER  
Risk of injury by electric shock  
Before you continue with this procedure, ensure that the DC  
power source is switched off.  
DANGER  
Risques de blessure par choc électrique  
Avant de poursuivre cette procédure, assurez-vous que la  
source d’alimentation en courant continu est éteinte.  
DANGER  
GEFAHR  
Verletzungsrisiko durch  
Stromschlag Bevor Sie dieses Verfahren fortsetzen, stellen Sie  
sicher, dass die Stromquelle für Wechselstrom ausgeschaltet  
ist.  
DANGER  
PELIGRO  
Riesgo de lesión por electrocución  
Antes de continuar con este proceso, asegúrese de que la  
fuente de alimentación de CC esté apagada.  
DANGER  
PERIGO  
Risco de ferimentos por choque elétrico  
Antes de continuar este procedimento, certifique-se de que a  
fonte de energia DC está desligada.  
DANGER  
PERICOLO  
Rischio di scosse elettriche  
Prima di continuare questa procedura, accertarsi che la fonte di  
alimentazione CC sia disattivata.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
NN46205-310 02.01 Standard  
30 May 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
Nortel Ethernet Routing Switch 8600  
Quick Start  
Copyright © 2008 Nortel Networks  
All Rights Reserved.  
Printed in Canada, India, and the United States of America  
Release: 5.0  
Publication: NN46205-310  
Document status: Standard  
Document revision: 02.01  
Document release date: 30 May 2008  
To provide feedback or to report a problem in this document, go to www.nortel.com/documentfeedback.  
LEGAL NOTICE  
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing  
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS  
OR IMPLIED. The information and/or products described in this document are subject to change without notice.  
Nortel, the Nortel logo, the Globemark, and Passport are trademarks of Nortel Networks.  
All other trademarks are the property of their respective owners.  
ATTENTION  
For information about the regulatory and safety precautions, read "Regulatory messages and safety  
precautions" in this guide.  
For information about the software license, read "Software license" in this guide.  
For a list of safety messages used in this guide and their translations, see "Translations of safety  
messages".  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Ventilation Hood 10 096 570 User Manual
MTD Snow Blower 317 140 000 User Manual
MTX Audio Stereo Amplifier TA7402 User Manual
Mustang Survival Life Jacket MD3081 User Manual
Network Technologies Switch ST C5KVM2ARS 1000S User Manual
Nikon Binoculars Monarch Gold E User Manual
Niles Audio Speaker CM4PR User Manual
Onkyo Speaker System Ls 3100 User Manual
Oregon Scientific Clock RRM612PA User Manual
Panasonic Vacuum Cleaner MC CG663 User Manual