Nortel Networks Switch 8306 User Manual

Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
Release: 4.1  
Document Revision: 01.01  
NN46200-309  
324403-A Rev 01  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
.
Regulatory Information and Safety  
Precautions  
Read the information in this section to learn about regulatory conformities  
and compliances.  
International Regulatory Statements of Conformity  
This is to certify that the Nortel 8300 Series chassis and components  
installed within the chassis were evaluated to the international regulatory  
standards for electromagnetic compliance (EMC) and safety and were  
found to have met the requirements for the following international  
standards:  
EMC - Electromagnetic Emissions – CISPR 22, Class A  
EMC - Electromagnetic Immunity – CISPR 24  
Electrical Safety – IEC 60950, with CB member national deviations  
Further, the equipment has been certified as compliant with the national  
standards as detailed below.  
National Electromagnetic Compliance (EMC) Statements of  
Compliance  
FCC Statement (USA only)  
This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to Part 15 of the Federal Communications  
Commission (FCC) rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can  
radiate radio frequency energy. If it is not installed and used in accordance  
with the instruction manual, it may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely  
to cause harmful interference, in which case users will be required to take  
whatever measures may be necessary to correct the interference at their  
own expense.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
6
Regulatory Information and Safety Precautions  
ICES Statement (Canada only)  
Canadian Department of Communications Radio Interference  
Regulations  
This digital apparatus (8300 Series chassis and installed components)  
does not exceed the Class A limits for radio-noise emissions from  
digital apparatus as set out in the Radio Interference Regulations of the  
Canadian Department of Communications.  
Règlement sur le Brouillage Radioélectrique du Ministère des  
Communications  
Cet appareil numérique (8300 Series chassis) respecte les limites de bruits  
radioélectriques visant les appareils numériques de classe A prescrites  
dans le Règlement sur le brouillage radioélectrique du ministère des  
Communications du Canada.  
CE Marking Statement (Europe only)  
EN 55 022 Statements  
This is to certify that the Nortel 8300 Series chassis and components  
installed within the chassis are shielded against the generation of radio  
interference in accordance with the application of Council Directive  
2004/108/EC. Conformity is declared by the application of EN 55 022  
Class A (CISPR 22).  
CAUTION  
This device is a Class A product. Operation of this equipment  
in a residential area is likely to cause harmful interference, in  
which case users are required to take appropriate measures  
necessary to correct the interference at their own expense.  
EN 55 024 Statement  
This is to certify that the Nortel 8300 Series chassis is shielded against the  
susceptibility to radio interference in accordance with the application of  
Council Directive 2004/108/EC. Conformity is declared by the application  
of EN 55 024 (CISPR 24).  
EN 300386 Statement  
The Ethernet Routing Switch 8300 Series chassis complies with the  
requirements of EN 300386 V1.3.3 for emissions and for immunity for a  
Class A device intended for use in either Telecommunications centre or  
locations other than telecommunications centres given the performance  
criteria as specified by the manufacturer.  
EC Declaration of Conformity  
This product conforms to the provisions of the R&TTE Directive  
1999/5/EC.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
MIC notice for 8310, and 8306 chassis (Republic of Korea only)  
7
European Union and European Free Trade Association (EFTA) Notice  
All products labeled with the CE marking comply with R&TTE Directive  
(1999/5/EEC) which includes the Electromagnetic Compliance (EMC)  
Directive (2004/108/EC) and the Low Voltage Directive (2006/95/EC)  
issued by the Commission of the European Community.  
Compliance with these directives implies conformity to the following  
European Norms (ENs). The equivalent international standards are listed  
in parenthesis.  
EN 55022 (CISPR 22)–Electromagnetic Interference  
EN 55024 (IEC 61000-4-2, -3, -4, -5, -6, -8, -11)–Electromagnetic  
Immunity  
EN 61000-3-2 (IEC 610000-3-2)–Power Line Harmonics  
EN 61000-3-3 (IEC 610000-3-3)–Power Line Flicker  
VCCI Statement (Japan/Nippon only)  
This is a Class A product based on the standard of the Voluntary Control  
Council for Interference (VCCI) for information technology equipment.  
If this equipment is used in a domestic environment, radio disturbance  
may arise. When such trouble occurs, the user may be required to take  
corrective actions.  
BSMI Statement for 8310, and 8306 Chassis (Taiwan only)  
This is a Class A product based on the standard of the Bureau of  
Standards, Metrology and Inspection (BSMI) CNS 13438, Class A.  
MIC notice for 8310, and 8306 chassis (Republic of Korea only)  
This device has been approved for use in Business applications only per  
the Class A requirements of the Republic of Korea Ministry of Information  
and Communications (MIC). This device may not be sold for use in a  
non-business application.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
8
Regulatory Information and Safety Precautions  
National Safety Statements of Compliance  
CE Marking Statement (Europe only)  
EN 60 950 Statement  
This is to certify that the Nortel 8300 Series chassis and components  
installed within the chassis are in compliance with the requirements of EN  
60 950 in accordance with the Low Voltage Directive. Additional national  
differences for all European Union countries have been evaluated for  
compliance. Some components installed within the 8300 Series chassis  
may use a nickel-metal hydride (NiMH) and/or lithium-ion battery. The  
NiMH and lithium-ion batteries are long-life batteries, and it is very possible  
that you will never need to replace them. However, should you need to  
replace them, refer to the individual component manual for directions on  
replacement and disposal of the battery.  
NOM Statement 8310 and 8306 Chassis (Mexico only)  
The following information is provided on the devices described in this  
document in compliance with the safety requirements of the Norma Oficial  
Méxicana (NOM):  
Exporter:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara CA 95054 USA  
Importer:  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Piso 30, Oficina  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
México D.F. 03900  
52 5 480 2100  
Tel:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Información NOM (unicamente para México)  
9
52 5 480 2199  
Fax:  
Input:  
(8306 and 8310 Chassis only)  
8301AC: 100 to 240 VAC 16A 47 to 60 Hz per power supply  
8301AC: 200 to 240 VAC 12 A 47 to 60 Hz per power supply  
single supply, single supply + one redundant supply, two supplies, or two  
supplies + one redundant supply configurations  
8302AC: 100 to 240 VAC 12A 47 to 60 Hz per power supply  
8302AC: 200 to 240 VAC 10A 47 to 60 Hz per power supply  
single supply, single supply + one redundant supply, two supplies, or two  
supplies + one redundant supply configurations  
8005DIDC: 40 to 75 VDC, 48.75 to 32.5 A  
single supply, single supply + one redundant supply, two supplies, or two  
supplies + one redundant supply configurations  
8005DC: 48 to 60 VDC, 42 to 34 A  
single supply, single supply + one redundant supply, two supplies, or two  
supplies + one redundant supply configurations  
Información NOM (unicamente para México)  
La información siguiente se proporciona en el dispositivo o en los  
dispositivos descritos en este documento, en cumplimiento con los  
requisitos de la Norma Oficial Méxicana (NOM):  
Exportador:  
Importador:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara, CA 95054 USA  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Piso 30, Oficina  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
México D.F. 03900  
52 5 480 2100  
Tel:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
10 Regulatory Information and Safety Precautions  
52 5 480 2199  
Fax:  
Embarcar a:  
(8306 and 8310 Chassis)  
8301AC:100 to 240 VAC 16A 47 to 60 Hz por fuente de poder  
8301AC: 200 to 240 VAC 12 A 47 to 60 Hz por fuente de poder  
una fuente, una fuente + configuraciones de una fuente redundante, dos  
fuentes o dos + configuraciones de una fuente redundante  
8302AC:100 to 240 VAC 12A 47 to 60 Hz por fuente de poder  
8302AC: 200 to 240 VAC 10 A 47 to 60 Hz por fuente de poder  
una fuente, una fuente + configuraciones de una fuente redundante, dos  
fuentes o dos + configuraciones de una fuente redundante  
8005DIDC: 40 to 75 VDC, 48.75 to 32.5 A  
una fuente, una fuente + configuraciones de una fuente redundante, dos  
fuentes o dos + configuraciones de una fuente redundante  
8005DC: 48 to 60 VDC, 42 to 34 A  
una fuente, una fuente + configuraciones de una fuente redundante, dos  
fuentes o dos + configuraciones de una fuente redundante  
Denan Statement (Japan/Nippon only)  
Safety Messages  
This section describes the different precautionary notices used in this  
document. This section also contains precautionary notices that you must  
read for safe operation of the Nortel Ethernet Routing Switch 8300.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Safety Messages 11  
Notices  
Notice paragraphs alert you about issues that require your attention.  
The following sections describe the types of notices. For a list of safety  
messages used in this guide and their translations, see "Translations of  
safety messages".  
Attention Notice  
ATTENTION  
An attention notice provides important information regarding the installation and  
operation of Nortel products.  
Caution ESD Notice  
CAUTION  
ESD  
ESD notices provide information about how to avoid discharge  
of static electricity and subsequent damage to Nortel products.  
CAUTION  
ESD (décharge électrostatique)  
La mention ESD fournit des informations sur les moyens de  
prévenir une décharge électrostatique et d’éviter d’endommager  
les produits Nortel.  
CAUTION  
ACHTUNG ESD  
ESD-Hinweise bieten Information dazu, wie man die  
Entladung von statischer Elektrizität und Folgeschäden an  
Nortel-Produkten verhindert.  
CAUTION  
PRECAUCIÓN ESD (Descarga electrostática)  
El aviso de ESD brinda información acerca de cómo evitar  
una descarga de electricidad estática y el daño posterior a los  
productos Nortel.  
CAUTION  
CUIDADO ESD  
Os avisos do ESD oferecem informações sobre como evitar  
descarga de eletricidade estática e os conseqüentes danos aos  
produtos da Nortel.  
CAUTION  
ATTENZIONE ESD  
Le indicazioni ESD forniscono informazioni per evitare scariche  
di elettricità statica e i danni correlati per i prodotti Nortel.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
12 Regulatory Information and Safety Precautions  
Caution Notice  
CAUTION  
Caution notices provide information about how to avoid possible  
service disruption or damage to Nortel products.  
CAUTION  
ATTENTION  
La mention Attention fournit des informations sur les moyens  
de prévenir une perturbation possible du service et d’éviter  
d’endommager les produits Nortel.  
CAUTION  
ACHTUNG  
Achtungshinweise bieten Informationen dazu, wie man mögliche  
Dienstunterbrechungen oder Schäden an Nortel-Produkten  
verhindert.  
CAUTION  
PRECAUCIÓN  
Los avisos de Precaución brindan información acerca de  
cómo evitar posibles interrupciones del servicio o el daño a los  
productos Nortel.  
CAUTION  
CUIDADO  
Os avisos de cuidado oferecem informações sobre como evitar  
possíveis interrupções do serviço ou danos aos produtos da  
Nortel.  
CAUTION  
ATTENZIONE  
Le indicazioni di attenzione forniscono informazioni per evitare  
possibili interruzioni del servizio o danni ai prodotti Nortel.  
Warning Notice  
WARNING  
Warning notices provide information about how to avoid  
personal injury when working with Nortel products.  
WARNING  
AVERTISSEMENT  
La mention Avertissement fournit des informations sur  
les moyens de prévenir les risques de blessure lors de la  
manipulation de produits Nortel.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety Messages 13  
WARNING  
WARNUNG  
Warnhinweise bieten Informationen dazu, wie man  
Personenschäden bei der Arbeit mit Nortel-Produkten  
verhindert.  
WARNING  
ADVERTENCIA  
Los avisos de Advertencia brindan información acerca de cómo  
prevenir las lesiones a personas al trabajar con productos  
Nortel.  
WARNING  
AVISO  
Os avisos oferecem informações sobre como evitar ferimentos  
ao trabalhar com os produtos da Nortel.  
WARNING  
AVVISO  
Le indicazioni di avviso forniscono informazioni per evitare danni  
alle persone durante l’utilizzo dei prodotti Nortel.  
Danger High Voltage Notice  
DANGER  
Danger—High Voltage notices provide information about how to  
avoid a situation or condition that can cause serious personal  
injury or death from high voltage or electric shock.  
DANGER  
La mention Danger—Tension élevée fournit des informations  
sur les moyens de prévenir une situation ou une condition qui  
pourrait entraîner un risque de blessure grave ou mortelle à la  
suite d’une tension élevée ou d’un choc électrique.  
DANGER  
GEFAHR  
Hinweise mit Vorsicht – Hochspannung“ bieten Informationen  
dazu, wie man Situationen oder Umstände verhindert, die zu  
schweren Personenschäden oder Tod durch Hochspannung  
oder Stromschlag führen können.  
DANGER  
PELIGRO  
Los avisos de Peligro-Alto voltaje brindan información acerca  
de cómo evitar una situación o condición que cause graves  
lesiones a personas o la muerte, a causa de una electrocución  
o de una descarga de alto voltaje.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
14 Regulatory Information and Safety Precautions  
DANGER  
PERIGO  
Avisos de Perigo—Alta Tensão oferecem informações sobre  
como evitar uma situação ou condição que possa causar graves  
ferimentos ou morte devido a alta tensão ou choques elétricos.  
DANGER  
PERICOLO  
Le indicazioni Pericolo—Alta tensione forniscono informazioni  
per evitare situazioni o condizioni che potrebbero causare gravi  
danni alle persone o il decesso a causa dell’alta tensione o di  
scosse elettriche.  
Danger Notice  
DANGER  
Danger notices provide information about how to avoid a  
situation or condition that can cause serious personal injury or  
death.  
DANGER  
La mention Danger fournit des informations sur les moyens de  
prévenir une situation ou une condition qui pourrait entraîner un  
risque de blessure grave ou mortelle.  
DANGER  
GEFAHR  
Gefahrenhinweise stellen Informationen darüber bereit, wie  
man Situationen oder Umständen verhindert, die zu schweren  
Personenschäden oder Tod führen können.  
DANGER  
PELIGRO  
Los avisos de Peligro brindan información acerca de cómo  
evitar una situación o condición que pueda causar lesiones  
personales graves o la muerte.  
DANGER  
PERIGO  
Avisos de perigo oferecem informações sobre como evitar uma  
situação ou condição que possa causar graves ferimentos ou  
morte.  
DANGER  
PERICOLO  
Le indicazioni di pericolo forniscono informazioni per evitare  
situazioni o condizioni che potrebbero causare gravi danni alle  
persone o il decesso.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
15  
.
Software license  
This section contains the Nortel Networks software license.  
Nortel Networks Inc. software license agreement  
This Software License Agreement ("License Agreement") is between  
you, the end-user ("Customer") and Nortel Networks Corporation and  
its subsidiaries and affiliates ("Nortel Networks"). PLEASE READ THE  
FOLLOWING CAREFULLY. YOU MUST ACCEPT THESE LICENSE  
TERMS IN ORDER TO DOWNLOAD AND/OR USE THE SOFTWARE.  
USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF  
THIS LICENSE AGREEMENT. If you do not accept these terms and  
conditions, return the Software, unused and in the original shipping  
container, within 30 days of purchase to obtain a credit for the full  
purchase price.  
"Software" is owned or licensed by Nortel Networks, its parent or one of  
its subsidiaries or affiliates, and is copyrighted and licensed, not sold.  
Software consists of machine-readable instructions, its components, data,  
audio-visual content (such as images, text, recordings or pictures) and  
related licensed materials including all whole or partial copies. Nortel  
Networks grants you a license to use the Software only in the country  
where you acquired the Software. You obtain no rights other than those  
granted to you under this License Agreement. You are responsible for the  
selection of the Software and for the installation of, use of, and results  
obtained from the Software.  
1. Licensed Use of Software. Nortel Networks grants Customer a  
nonexclusive license to use a copy of the Software on only one machine  
at any one time or to the extent of the activation or authorized usage level,  
whichever is applicable. To the extent Software is furnished for use with  
designated hardware or Customer furnished equipment ("CFE"), Customer  
is granted a nonexclusive license to use Software only on such hardware  
or CFE, as applicable. Software contains trade secrets and Customer  
agrees to treat Software as confidential information using the same care  
and discretion Customer uses with its own similar information that it does  
not wish to disclose, publish or disseminate. Customer will ensure that  
anyone who uses the Software does so only in compliance with the terms  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
16 Software license  
of this Agreement. Customer shall not a) use, copy, modify, transfer  
or distribute the Software except as expressly authorized; b) reverse  
assemble, reverse compile, reverse engineer or otherwise translate the  
Software; c) create derivative works or modifications unless expressly  
authorized; or d) sublicense, rent or lease the Software. Licensors of  
intellectual property to Nortel Networks are beneficiaries of this provision.  
Upon termination or breach of the license by Customer or in the event  
designated hardware or CFE is no longer in use, Customer will promptly  
return the Software to Nortel Networks or certify its destruction. Nortel  
Networks may audit by remote polling or other reasonable means to  
determine Customer’s Software activation or usage levels. If suppliers of  
third party software included in Software require Nortel Networks to include  
additional or different terms, Customer agrees to abide by such terms  
provided by Nortel Networks with respect to such third party software.  
2. Warranty. Except as may be otherwise expressly agreed to in  
writing between Nortel Networks and Customer, Software is provided  
"AS IS" without any warranties (conditions) of any kind. NORTEL  
NETWORKS DISCLAIMS ALL WARRANTIES (CONDITIONS) FOR THE  
SOFTWARE, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT  
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF  
NON-INFRINGEMENT. Nortel Networks is not obligated to provide support  
of any kind for the Software. Some jurisdictions do not allow exclusion  
of implied warranties, and, in such event, the above exclusions may not  
apply.  
3. Limitation of Remedies. IN NO EVENT SHALL NORTEL  
NETWORKS OR ITS AGENTS OR SUPPLIERS BE LIABLE FOR ANY  
OF THE FOLLOWING: a) DAMAGES BASED ON ANY THIRD PARTY  
CLAIM; b) LOSS OF, OR DAMAGE TO, CUSTOMER’S RECORDS,  
FILES OR DATA; OR c) DIRECT, INDIRECT, SPECIAL, INCIDENTAL,  
PUNITIVE, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST  
PROFITS OR SAVINGS), WHETHER IN CONTRACT, TORT OR  
OTHERWISE (INCLUDING NEGLIGENCE) ARISING OUT OF  
YOUR USE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS,  
ITS AGENTS OR SUPPLIERS HAVE BEEN ADVISED OF THEIR  
POSSIBILITY. The forgoing limitations of remedies also apply to any  
developer and/or supplier of the Software. Such developer and/or supplier  
is an intended beneficiary of this Section. Some jurisdictions do not allow  
these limitations or exclusions and, in such event, they may not apply.  
4. General  
1. If Customer is the United States Government, the following paragraph  
shall apply: All Nortel Networks Software available under this License  
Agreement is commercial computer software and commercial computer  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Nortel Networks Inc. software license agreement 17  
software documentation and, in the event Software is licensed for  
or on behalf of the United States Government, the respective rights  
to the software and software documentation are governed by Nortel  
Networks standard commercial license in accordance with U.S. Federal  
Regulations at 48 C.F.R. Sections 12.212 (for non-DoD entities) and  
48 C.F.R. 227.7202 (for DoD entities).  
2. Customer may terminate the license at any time. Nortel Networks  
may terminate the license if Customer fails to comply with the terms  
and conditions of this license. In either event, upon termination,  
Customer must either return the Software to Nortel Networks or certify  
its destruction.  
3. Customer is responsible for payment of any taxes, including personal  
property taxes, resulting from Customer’s use of the Software.  
Customer agrees to comply with all applicable laws including all  
applicable export and import laws and regulations.  
4. Neither party may bring an action, regardless of form, more than two  
years after the cause of the action arose.  
5. The terms and conditions of this License Agreement form the complete  
and exclusive agreement between Customer and Nortel Networks.  
6. This License Agreement is governed by the laws of the country in  
which Customer acquires the Software. If the Software is acquired in  
the United States, then this License Agreement is governed by the  
laws of the state of New York.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
18 Software license  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
19  
.
New in this release  
The following sections detail what’s new in Nortel Ethernet Routing Switch  
8300 Installation — Chassis Installation and Maintenance, NN46200-309  
for Release 4.1:  
Features  
See the following sections for information about feature changes:  
8005DC power supply  
Release 4.1 introduces the 8005DC power supply. For more information,  
61).  
Dual input DC-DC switching power supply  
Release 4.1 introduces a dual input DC-DC switching power supply—the  
8005DI DC. For more information, see “Ethernet Routing Switch 8005DI  
Other changes  
See the following sections for information about changes that are not  
feature-related:  
Document changes  
This document is restructured to align with Nortel Customer  
Documentation Standards.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
           
20 New in this release  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
21  
.
Introduction  
The Nortel Ethernet Routing Switch 8300 chassis provides the physical  
framework for the Nortel Ethernet Routing Switch 8300 modules.  
This document provides the instructions for installing the Nortel Ethernet  
Routing Switch 8300 chassis (8306 and 8310 chassis) in an equipment  
rack. This document also describes some of the routine tasks that you use  
to operate the Nortel Ethernet Routing Switch 8300 and includes technical  
specifications for the chassis and modules.  
Prerequisites  
Before you install the Ethernet Routing Switch 8300 chassis, ensure  
that you use standard cable-system practices to install all network  
wiring on the premises.  
Navigation  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
22 Introduction  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
23  
.
Chassis installation fundamentals  
This chapter describes fundamental information that you need for installing  
the Ethernet Routing Switch 8300 chassis (8306 and 8310 chassis) .  
Each Ethernet Routing Switch 8300 chassis consists of a sheet metal  
enclosure and a backplane. The number of bays for fan trays depends  
on the chassis type.  
For information about the minimum software versions required to support  
the hardware, see Nortel Ethernet Routing Switch 8300 Administration,  
NN46200-604.  
This section includes information about the following chassis types:  
Ethernet Routing Switch 8310 chassis  
Ethernet Routing Switch 8306 chassis  
Navigation  
Ethernet Routing Switch 8310 chassis  
The Ethernet Routing Switch 8310 chassis provides eight slots for  
installing Ethernet Routing Switch 8300 I/O modules and two slots for  
installing the Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
24 Chassis installation fundamentals  
modules. Slots are numbered from the top down. You can install 8300  
Series I/O switch modules in slots 1 through 4 and slots 7 through 10.  
Slots 5 and 6 are reserved for the 8393SF/CPU or 8394SF/CPU modules.  
The Ethernet Routing Switch 8310 chassis has three bays for either AC  
or DC power supplies and two fan trays for cooling. Figure 1 "Ethernet  
location of customer-replaceable components in the Ethernet Routing  
Switch 8310 chassis.  
The Ethernet Routing Switch 8310 chassis includes a Power over Ethernet  
(PoE) backplane that supports 802.3af PoE. The PoE feature requires the  
following components:  
Ethernet Routing Switch 8306 or 8310 chassis with PoE backplane  
Ethernet Routing Switch 8301AC or 8302AC power supply  
Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU module  
and a choice of either of the following:  
Ethernet Routing Switch 8348TX-PWR module  
Ethernet Routing Switch 8348GTX-PWR module  
CAUTION  
Risk of equipment damage  
Do not install Ethernet Routing Switch 8300 modules and  
Ethernet Routing Switch 8100 or 8600 modules within the same  
chassis. Ethernet Routing Switch 8300 Series software does  
not support mixed configurations. A mixed configuration can  
damage the modules and void your warranty.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Ethernet Routing Switch 8306 chassis 25  
Figure 1  
Ethernet Routing Switch 8310 chassis and components  
Ethernet Routing Switch 8306 chassis  
The Ethernet Routing Switch 8306 chassis provides four slots for  
installing I/O modules and two slots for installing Ethernet Routing Switch  
8393SF/CPU or 8394SF/CPU modules. See Figure 2 "8306 chassis and  
components" (page 26). You can use the top four slots to install 8300 I/O  
switch modules. Slots 5 and 6 are reserved for Ethernet Routing Switch  
8393SF/CPU or 8394SF/CPU modules.  
The Ethernet Routing Switch 8306 chassis has three bays for either  
AC or DC power supplies and a single fan tray for cooling. Figure 2  
"8306 chassis and components" (page 26) also shows the location of  
customer-replaceable components in the 8306 chassis.  
The Ethernet Routing Switch 8306 chassis includes a PoE backplane that  
supports 802.3af PoE. The PoE feature requires the following components:  
Ethernet Routing Switch 8306 or 8310 chassis with PoE backplane  
Ethernet Routing Switch 8301AC or 8302AC power supply  
Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU module  
and a choice of either of the following:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
26 Chassis installation fundamentals  
Ethernet Routing Switch 8348TX-PWR module or  
Ethernet Routing Switch 8348GTX-PWR module  
CAUTION  
Risk of equipment damage  
Do not install Ethernet Routing Switch 8300 modules and  
Ethernet Routing Switch 8100 or 8600 modules within the same  
chassis. Ethernet Routing Switch 8300 Series software does  
not support mixed configurations. A mixed configuration can  
damage the modules and void your warranty.  
Figure 2  
8306 chassis and components  
Power supplies  
The Ethernet Routing Switch 8306 and 8310 chassis each provide three  
bays for either AC or DC power supplies.  
The Ethernet Routing Switch 8306 and 8310 chassis supports the  
following AC power supplies:  
8301AC  
8302AC  
The Ethernet Routing Switch 8306 and 8310 chassis supports the  
following DC power supplies:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Site requirements 27  
8005DC  
8005DI DC,  
The PoE feature requires the following components:  
Ethernet Routing Switch 8306 or 8310 chassis with PoE backplane  
Ethernet Routing Switch 8301AC or 8302AC power supply  
Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU module  
and a choice of either of the following:  
Ethernet Routing Switch 8348TX-PWR module  
Ethernet Routing Switch 8348GTX-PWR module  
Fan trays  
the number of fan trays for the Ethernet Routing Switch 8310 and 8306  
chassis.  
Table 1  
Number of fan trays installed for each chassis  
Chassis  
8310  
Fan tray  
Two fan trays; each fan tray contains eight high-capacity fans.  
One fan tray containing six high-capacity fans.  
8306  
A control/monitor circuit board in the fan tray reports temperature and  
fan operating status to the network management software. A green light  
emitting diode (LED) indicates that the fan tray is operating correctly. For  
information about installing the fan, see Nortel Ethernet Routing Switch  
8300 Installation — Fan Tray, (NN46200-302).  
Site requirements  
Ensure that the installation site meets the space, electrical, and  
environmental requirements listed in this section. For more information  
Space requirements  
The installation site must provide sufficient free space around the chassis  
to ensure proper ventilation and access for servicing.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
     
28 Chassis installation fundamentals  
Use the following guidelines to plan front and rear access:  
The maintenance aisle in front of the frame requires a clearance of  
76.2 centimeters (cm) (30 inches).  
The wiring aisle at the back of the frame requires a clearance of 61 cm  
(24 inches).  
AC input electrical requirements  
Refer to the power specifications for the power supply in “Technical  
For AC input power specifications for each of the modules, see Nortel  
Ethernet Routing Switch 8300 Installation — Modules, (NN46205-305).  
Environmental requirements  
The installation site must meet the following environmental requirements  
for 8300 chassis operation. For more information, see the following table.  
Table 2  
Environmental requirements  
Altitude  
Humidity  
Temperature  
0-10 000 feet (ft)  
(0-3 048 meters [m])  
5%-85%, noncondensing  
32 F-104 F (0 C-40 C),  
stable  
Hardware requirements  
This section includes information about the hardware shipped with the  
8306 and 8310 chassis.  
Shipment contents  
In addition to the Ethernet Routing Switch 8310 or 8306 chassis, your  
shipping container contains several hardware accessories. Verify that the  
items in the shipping container match those on the shipment packing list.  
The following table is a checklist of items included in the shipment  
container. For information about ordering replacement parts, see “Part  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Hardware requirements 29  
Table 3  
Chassis shipping accessories: Ethernet Routing Switch 8310 and 8306  
chassis  
Accessory  
Use to  
Check  
Prepare the chassis for installation  
in an equipment rack.  
Bracket kit containing the  
following:  
two rack mounting brackets  
bracket- mounting machine  
screws, each being 0.164  
inches wide, 32 threads to  
the inch and 0.250 inches  
long  
— The 8310 chassis ships  
with 24 of these screws.  
— The 8306 chassis ships  
with 14 of these screws.  
Mount the chassis in an equipment  
rack.  
Screw package containing  
wafer head screws each being  
0.190 inches wide, 32 threads  
to the inch and 0.75 inches long  
with flat nylon washers:  
The 8310 chassis ships with  
14 of each.  
The 8306 chassis ships with  
10 of each.  
2 side cable management  
brackets  
Manage network interface cables.  
Rubber footpads  
Keep the chassis from slipping  
when mounting it on a flat surface.  
Console cable  
Connect an optional management  
console to the chassis.  
The following figures illustrate the items included in the chassis shipping  
container.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
30 Chassis installation fundamentals  
Figure 3  
Items in the Ethernet Routing Switch 8310 chassis shipping container  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Hardware requirements 31  
Figure 4  
Items in the Ethernet Routing Switch 8306 chassis shipping container  
Other equipment  
In addition to the items that are included in the Ethernet Routing Switch  
8310 and 8306 chassis accessory package you must also supply other  
items. Before you install the hardware, ensure that you have all the cables,  
tools, and other equipment that you need. The following sections describe  
the equipment you must supply:  
Management console  
To configure startup options and to monitor the results of startup  
diagnostics, you can attach an optional PC, or laptop, VT-100 console or  
an equivalent, such as a PC terminal emulator.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
32 Chassis installation fundamentals  
Cables  
Unless you specifically order them, the cables required for your network  
configuration are not included in the chassis accessory package. If you do  
not have the proper cables, contact your network administrator.  
Mounting hardware for the 8310, 8306 chassis  
To install the Ethernet Routing Switch 8310 or 8306 chassis in an  
equipment rack, you require a Phillips screwdriver and an equipment rack  
that meets the following specifications:  
heavy-duty steel construction  
Electronic Industries Association (EIA) standard hole-spacing  
width of 19 inches (in.) (48.26 centimeters [cm]) and depth of 24 in.  
(60.96 cm)  
For information about chassis weight including components, see  
Successful installation verification  
In a normal power-up sequence, the LEDs light as follows:  
1. When power is applied to the Ethernet Routing Switch 8300 Series, the  
green LED on each power supply and fan tray turns on, and the Online  
LED for each module lights amber.  
2. Each module initiates a self-test, during which the port and module  
LEDs display various patterns to indicate the progress of the self-test.  
3. On successful completion of the self-test (within two or three minutes  
after power is applied for a fully loaded chassis), the module Online  
LED transitions from amber to green.  
If the LEDs on the modules light in this sequence, your installation is  
successful. Contact your network administrator to verify that the Ethernet  
Routing Switch 8300 Series is now connected to the network.  
If the LEDs do not light in this sequence, contact your local Nortel  
Technical Solutions Center.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
     
33  
.
Ethernet Routing Switch 8310 and 8306  
chassis installation  
This section describes how to install the Ethernet Routing Switch 8310  
and 8306 chassis.  
CAUTION  
ESD  
To prevent damage from electrostatic discharge, always wear  
an antistatic wrist strap connected to an electrostatic discharge  
(ESD) jack when performing maintenance on this product.  
Ensure that the wrist strap makes contact with your skin.  
Prerequisites  
Inspect all items for shipping damage. If you detect damage, do not  
install the chassis. Call the Nortel Technical Solutions Center in your  
area.  
Verify that the items in the shipping container match those on the  
checklist when verifying the contents of the shipping container.  
Verify that you have supplied all the other required hardware.  
Ensure that your installation site meets the physical, electrical, and  
environmental requirements described in “Site requirements” (page  
27).  
Chassis installation procedures  
This task flow shows you the sequence of procedures you perform to  
install the chassis. To link to a procedure, click the procedure title in  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
34 Ethernet Routing Switch 8310 and 8306 chassis installation  
Navigation  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing the chassis on a flat surface 35  
Chassis installation time requirements  
The following table lists procedures you must use to install the Nortel  
Ethernet Routing Switch 8300 chassis and the estimated time you need  
to complete each procedure. Not all procedures are required for every  
Ethernet Routing Switch 8300 system.  
Procedure  
Time requirement  
Positioning the chassis on a flat surface  
Mounting the chassis in an equipment rack  
Installing the cable management brackets  
5 minutes  
9–17 minutes depending on the chassis  
5 minutes  
Reducing the chassis weight  
Reduce the chassis weight to make the chassis easier to lift, and thus  
you can reduce the risk of personal injury or equipment damage. This  
procedure requires approximately 5 minutes to complete.  
Procedure steps  
Step Action  
1
2
3
Remove the power supply filler panels.  
For more information, see Nortel Ethernet Routing Switch 8300  
Installation — AC Power Supply, NN46200-301.  
Remove the module filler panels.  
For more information, see Nortel Ethernet Routing Switch 8300  
Installation — Modules, NN46200-305.  
Remove the fan trays.  
For more information see Nortel Ethernet Routing Switch 8300  
Installation — Fan Tray, NN46200-302.  
--End--  
Installing the chassis on a flat surface  
Mount the Ethernet Routing Switch 8310 and 8306 chassis on any flat,  
level surface, such as a tabletop or shelf, that can safely support the  
weight of the chassis, its components, and its attached cables to provide a  
convenient location for the safe operation of the switch.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
     
36 Ethernet Routing Switch 8310 and 8306 chassis installation  
Prerequisites  
Provide adequate space around the unit for access to cable  
connectors.  
Ensure that the surface can safely support the weight of the chassis,  
its components, and its attached cables. See “Chassis installation time  
Procedure steps  
Step  
1
Action  
Set the switch on the flat surface and check for proper  
ventilation.  
Allow at least 2 inches 5.1 cm) on each side for proper  
ventilation and 5 inches (12.7 cm) at the front for power cord  
clearance.  
2
3
Attach rubber feet to each marked location on the bottom of the  
chassis.  
The rubber feet are optional but recommended to keep the unit  
from slipping.  
Attach all devices to the ports.  
--End--  
Procedure job aid: Chassis weight including components  
The following table shows the weight of each chassis including the  
components.  
Chassis  
8310  
Maximum weight (chassis and components)  
225 pounds (lb) (102 kilograms [kg])  
140 lb (63 kg)  
8306  
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in  
an equipment rack  
Install the Ethernet Routing Switch 8310 and 8306 chassis in a standard  
19-inch equipment rack to provide a convenient location for the safe  
operation of the switch.  
ATTENTION  
If you are mounting the chassis in a 23-inch equipment rack, see the rack  
manufacturer’s 23-inch-to-19-inch rack adapter installation instructions.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack 37  
Prerequisites  
To mount the chassis in an equipment rack, you need the following  
equipment:  
standard 19 in. (48.2 cm) equipment rack  
two rack mounting brackets  
14 Machine screws for the mounting brackets on the 8306 chassis  
(22 Machine screws for the brackets on the 8310 chassis)  
10 WAFER head screws and washers for the 8306 chassis (14  
WAFER head screws and washers for the 8310 chassis)  
a Phillips screwdriver  
CAUTION  
in 7-foot rack” (page 40) for the maximum number of chassis  
that you can install in a 7-foot rack.  
Procedure steps  
Step  
1
Action  
Hold each rack-mounting bracket against one side of the  
chassis. Make sure that the attachment holes in the bracket  
match the holes in the chassis.  
Each bracket fits only one side of the chassis. The brackets are  
labeled R (right) and L (left). If the mounting holes do not line up  
between a bracket and the chassis, try that bracket on the other  
side of the chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
38 Ethernet Routing Switch 8310 and 8306 chassis installation  
2
Insert and tighten the supplied flat-head screws to fasten each  
bracket to the chassis.  
3
Measure the appropriate number of rack units of free vertical  
space inside the rack and mark the spot.  
The following table shows the number of rack units you can  
allocate for each chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack 39  
Chassis  
8310  
Rack units  
13.2  
Inches  
23.06  
16.9  
8306  
9.7  
4
Holding the chassis in position, align the flanged end of each  
mounting rail with two holes on each side of the vertical rack  
support.  
It is easier to complete this step with two people. Make sure  
that the hole pairs on either side of the vertical support match  
horizontally.  
5
Insert and tighten the rack-mounting screws with a Phillips  
screwdriver.  
Do not overtighten the rack-mounting screws.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
40 Ethernet Routing Switch 8310 and 8306 chassis installation  
--End--  
Procedure job aid: Maximum number of chassis installed in 7-foot rack  
The following table shows the maximum number of chassis that you can  
install in a 7-foot rack.  
Chassis  
8310  
Maximum number of chassis installed in 7-foot rack  
3
4
8306  
Installing the cable guides  
Install the cable guides to keep cable clusters fastened and out of the way,  
but still accessible for maintenance.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Installing the cable guides 41  
Procedure steps  
Step  
1
Action  
Loosen, but do not remove, the rack-mounting screws needed to  
install one cable guide.  
2
Slide the guide onto the loosened screws.  
3
Tighten the screws to secure the guide to the chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
42 Ethernet Routing Switch 8310 and 8306 chassis installation  
--End--  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
43  
.
Switch operations  
This chapter describes some of the procedures that you perform to  
operate the Ethernet Routing Switch 8300 and provides troubleshooting  
information.  
Navigation  
Powering on DC power supplies  
Power on the DC power supplies to provide power to the switch.  
Prerequisites  
Ensure that the power supply is seated properly.  
Procedure steps  
Step  
1
Action  
On each DC power supply, turn the power switch to the On  
position.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
44 Switch operations  
ATTENTION  
When you first install a chassis that contains two or three  
power supplies, you must turn on two of the power supply units  
simultaneously. If you wait longer to turn on the second power  
supply, one of the power supplies could shut down. To correct this  
condition, turn off both power supplies, wait at least 30 seconds, and  
then turn on both power supplies again simultaneously.  
For more information about the power switch locations, see the  
following figure.  
2
3
Verify that the power output LED for each power supply lights  
green.  
Verify that the power supply status LEDs and the fan LED on the  
8393SF/CPU or 8394SF/CPU module light green.  
After you turn on the switch, each module automatically  
initiates a diagnostic test to verify proper module function. See  
4
5
Verify that air is flowing from the cooling fans out through the  
vents of the chassis.  
If the power supply LED remains off, or if you cannot feel air flow  
from the chassis vents, turn the DC power supplies off, and then  
turn them on again.  
6
If the problem persists, contact the Nortel Technical Solutions  
Center.  
--End--  
Powering on AC power supplies  
Power on the AC power supplies to provide power to the switch.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Resetting the switch 45  
The number of supported Power over Ethernet (PoE) modules depends on  
the power supply rating (110 volts [V]AC nominal or 220 VAC nominal),  
the power supply model, and the number of power supplies. For more  
information, see Ethernet Routing Switch 8300 Planning — Power  
Considerations, (NN46200-511).  
Prerequisites  
Ensure that the power supply is seated properly.  
Verify that the AC power cords are connected to the power supplies  
and connected to AC power outlets.  
Procedure steps  
Step  
1
Action  
On each AC power supply, turn the power switch to the on  
position.  
ATTENTION  
When you first install a chassis that contains two or three  
power supplies, you must turn on two of the power supply units  
simultaneously. If you wait longer to turn on the second power  
supply, one of the power supplies could shut down. To correct this  
condition, turn off both power supplies, wait at least 30 seconds, and  
then turn on both power supplies again simultaneously.  
2
3
Verify that the power LED on each power supply lights green.  
Verify that the power supply status LEDs and the fan LED on the  
8393SF/CPU or 8394SF/CPU module light green.  
After you turn on the switch, each module automatically  
initiates a diagnostic test to verify proper module function. See  
4
5
Verify that air is flowing from the cooling fans out through the  
vents of the chassis.  
If the power supply LED remains off, or if you cannot feel air flow  
from the chassis vents, turn the DC power supplies off, and then  
turn them on again.  
6
If the problem persists, contact the Nortel Technical Solutions  
Center.  
--End--  
Resetting the switch  
Reset the switch to reboot the switch hardware without cycling power.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
46 Switch operations  
Procedure steps  
Action  
To warm-start the Ethernet Routing Switch 8300 Series (no  
diagnostic tests are run), press the Reset button for less than 5  
seconds.  
To press the Reset button, insert a small pointed object (for  
example, an unbent paper clip) into the Reset button hole.  
The following figure shows the location of the Reset button on  
the Ethernet Routing Switch 8393SF/CPU module.  
Figure 5  
Reset button on the 8393SF/CPU module  
The following figure shows the location of the Reset button on  
the Ethernet Routing Switch 8394SF/CPU module.  
Figure 6  
Reset button on the 8394SF/CPU module  
Installing removable flash memory cards  
Install a removable flash memory card in an Ethernet Routing Switch  
8393SF/CPU module to provide alternative storage media.  
Procedure steps  
Step Action  
1
Position the card with the label facing up and the insert arrow  
pointing toward the card receptacle.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Removing removable flash memory cards 47  
2
3
Insert the card into the card receptacle.  
Gently push the card in until it fits snugly in place.  
--End--  
Removing removable flash memory cards  
Remove a removable flash memory card from the Ethernet Routing  
Switch 8393SF/CPU or 8394SF/CPU module to stop using it as a storage  
medium.  
Procedure steps  
Step Action  
1
Press the eject button to the side of the memory card receptacle  
on the Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU  
module.  
The card pops out slightly.  
2
Pull the flash memory card out of the card receptacle.  
--End--  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
48 Switch operations  
Protecting memory card files  
Write-protect the memory card for backup purposes after you successfully  
load the configuration file and save your configuration because Nortel  
ships each memory card with the read-write protect switch in the  
unprotected position.  
Typically, you do not operate the switch with a write-protected memory  
card. Make a copy of your configuration on another memory card,  
write-protect that card, and store it in a safe place. If you do not have a  
second memory card, you can copy your configuration to a File Transfer  
Protocol (FTP) or Trivial FTP (TFTP) server.  
Prerequisites  
Remove the card from the Ethernet Routing Switch 8393SF/CPU or  
8394SF/CPU module before changing the read-write protection.  
ATTENTION  
You must remove the card from the Ethernet Routing Switch 8393SF/CPU  
or 8394SF/CPU module before changing the read-write protection. Failure to  
remove the card can result in improper write protection.  
Procedure steps  
Step  
1
Action  
Remove the memory card from the Ethernet Routing Switch  
8393SF/CPU or 8394SF/CPU module.  
2
Locate the read-write protect switch on the edge opposite the  
arrow on the memory card.  
3
Adjust the read-write protect switch.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Protecting memory card files 49  
4
Reinsert the memory card into the card receptacle.  
--End--  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
50 Switch operations  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
51  
.
Part Numbers  
This chapter provides a list of Nortel Ethernet Routing Switch 8300  
hardware and part numbers.  
The following table lists Ethernet Routing Switch 8300 hardware and part  
numbers.  
Table 4  
Ethernet Routing Switch 8300 hardware part numbers  
Part number  
Item  
Additional details  
DS1402007-E5  
8310 10 slot Power over  
Ethernet (PoE) chassis  
Includes chassis, dual  
backplane, two fan trays,  
RS232 cable the for the  
management console, rack  
mount kit, and cable guide kit.  
Requires at least one 83XX  
power supply, and up to three  
power supplies are supported.  
DS1402008-E5  
8306 6 slot PoE chassis  
Includes chassis, dual  
backplane, two fan trays,  
RS232 cable the for the  
management console, rack  
mount kit, and cable guide kit.  
Requires at least one 83XX  
power supply, and up to three  
power supplies are supported.  
DS1404076-E5  
Ethernet Routing Switch  
8393SF CPU/Switch Fabric  
Includes Personal Computer  
Memory Card International  
module with 8 Gigabit Ethernet Association (PCMCIA) flash  
SFP slots  
memory card.  
One switch fabric module is  
required for each Ethernet  
Routing Switch 8300 chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
52 Part Numbers  
Table 4  
Ethernet Routing Switch 8300 hardware part numbers (cont’d.)  
Part number  
Item  
Additional details  
DS1404099-E5  
Ethernet Routing Switch  
8394SF CPU/Switch Fabric  
module with 2 - 10 Gigabit  
Ethernet XFP slots  
Includes PCMCIA flash  
memory card.  
One switch fabric module is  
required for each Ethernet  
Routing Switch 8300 chassis.  
DS1404077-E5  
Ethernet Routing Switch  
8348TX module. 48 port  
autosensing 10BASET/  
100BASE-TX Ethernet  
interface module  
Ethernet Routing Switch  
8348TX-PWR module, 48  
10BASE-T/100BASE-TX ports  
Ethernet interface module  
DS1404078  
Ethernet Routing Switch  
DS1404079-E5  
8324GTX module, 24 port  
autonegotiating (10BASE-T,  
100BASE-TX, or 1000BASE-T)  
Ethernet interface module  
DS1404098-E5  
DS1404093-E5  
Ethernet Routing Switch  
8324FX. 24 Port 100Base-FX  
Ethernet interface module  
Ethernet Routing Switch  
8348GTX module. 48  
port Autosensing 10Base-  
T/100Base-TX/1000Base-T  
Ethernet interface module  
Ethernet Routing Switch  
DS1404094-E5  
8348GTX-PWR module, 48  
port Autonegotiating 10BASE-T  
/100BASE-TX / 1000BASE-T,  
Ethernet interface module  
DS1404095-E5  
DS1404100-E6  
Ethernet Routing Switch  
8348GB module. 48 port SFP  
interface module  
Ethernet Routing Switch  
8308XL module 8 port 10  
GBase XFP Ethernet interface  
module  
The 10GBASE-R ports on this  
module are LAN-capable and  
operate in full-duplex mode.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Protecting memory card files 53  
Table 4  
Ethernet Routing Switch 8300 hardware part numbers (cont’d.)  
Part number  
Item  
Additional details  
DS1405A14-E5  
8301AC 100-240 volts (V) AC  
Power Supply. At least one  
power supply is required for  
each 83xx chassis.  
Provides up to 800W of PoE.  
Does not include a power cord.  
DS1405x16-E5  
DS1405011-E5  
DS1405017-E6  
8302AC 100-240 V AC Power  
Supply. At least one power  
supply is required for each  
83xx chassis.  
Provides up to 400W of PoE.  
Does not include a power cord.  
8005DC 48-60 V DC Power  
Supply. At least one power  
supply is required for each  
83xx chassis.  
8005DI DC 40-70 V DC Power  
Supply. At least one power  
supply is required for each  
83xx chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
54 Part Numbers  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
55  
.
Technical specifications  
This chapter lists the physical, environmental, and electrical specifications  
for the Ethernet Routing Switch 8310 and 8306 chassis and the available  
power supplies.  
Navigation  
Ethernet Routing Switch 8310 chassis specifications  
The following sections describe the specifications of the Ethernet Routing  
Switch 8310 chassis.  
Physical specifications  
The following table lists the physical specifications of the Ethernet Routing  
Switch 8310 chassis.  
Table 5  
Ethernet Routing Switch 8310 chassis physical specifications  
Physical specifications  
Height:  
22.9 inches (in.) (58.2 centimeters  
[cm])  
Width:  
17.5 in. (44.5 cm)  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
     
56 Technical specifications  
Table 5  
Ethernet Routing Switch 8310 chassis physical specifications (cont’d.)  
Physical specifications  
Depth:  
19.9 in. (50.5 cm)  
Weight (empty):  
Weight (fully loaded):  
Cooling system:  
Fan trays:  
85 pounds (lb) (39 kilograms [kg])  
225 lb (102 kg)  
2 per chassis  
8 per fan tray  
1 per fan tray  
Fans:  
Thermal sensors:  
Environmental specifications  
The following table lists the environmental specifications of the Ethernet  
Routing Switch 8310 chassis.  
Table 6  
Ethernet Routing Switch 8310 chassis environmental specifications  
Environmental specifications  
Operating temperature:  
0 degrees Celcius( C) to 40 C (32 degrees  
Fahrenheit [ F] to 104 F)  
Storage temperature:  
Operating humidity:  
Storage humidity:  
Operating altitude:  
Storage altitude:  
Free fall/drop:  
–25 C to 70 C (–13 F to 158 F)  
85% maximum relative humidity, noncondensing  
95% maximum relative humidity, noncondensing  
3 048 meters (m) (10 000feet [ft]) maximum  
3 048 m (10 000 ft) maximum  
ISO 4180-s, NSTA 1A  
Vibration:  
IEC 68-2-6/34  
Shock/bump:  
IEC 68-2-27-29  
International regulatory requirements  
The following table lists the international regulatory requirements of the  
Ethernet Routing Switch 8310 chassis.  
Table 7  
Ethernet Routing Switch 8310 international regulatory requirements  
International regulatory requirements  
Electromagnetic emissions  
regulatory requirements:  
Global basis for certification:  
CISPR 22-1997 Class A  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Ethernet Routing Switch 8306 chassis specifications 57  
Table 7  
Ethernet Routing Switch 8310 international regulatory requirements (cont’d.)  
International regulatory requirements  
U.S.:  
FCC CFR47 Part 15, Subpart B, Class  
A
Canada:  
Europe:  
ICES-003, Issue-2, Class A  
EN 55022-1998 Class A; EN  
61000-3-2/A14, EN 61000-3-3 (CE  
Marking  
Australia/New Zealand:  
Japan:  
AS/NZS 3548:1995, Class A  
VCCI-V3/97.04, Class A  
CNS 13438, Class A  
Taiwan:  
Electromagnetic immunity regulatory requirements:  
Global basis for certification:  
Europe:  
CISPR 24:1997  
EN 55024:1998  
Safety regulatory requirements:  
Global basis for certification:  
IEC 60950 current edition with all CB  
member deviations  
U.S.:  
UL60950  
Canada:  
CSA 22.2 No. 60950  
EN60950 (CE Marking)  
AS/NZS 3260  
Europe:  
Australia/New Zealand:  
Mexico:  
NOM-019-SCFI-1998  
Ethernet Routing Switch 8306 chassis specifications  
The following sections describe the specifications of the Ethernet Routing  
Switch 8306 chassis.  
Physical specifications  
The following table lists the physical specifications of the Ethernet Routing  
Switch 8306 chassis.  
Table 8  
Ethernet Routing Switch 8306 physical specifications  
Physical specifications  
Height:  
15.8 in. (40.1 cm)  
17.5 in. (44.5 cm)  
19.9 in. (50.5 cm)  
49 lb (22 kg)  
Width:  
Depth:  
Weight (empty):  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
58 Technical specifications  
Table 8  
Ethernet Routing Switch 8306 physical specifications (cont’d.)  
Physical specifications  
Weight (fully loaded):  
Cooling system:  
Fan tray:  
140 lb (63 kg)  
1 per chassis  
6 per fan tray  
1 per fan tray  
Fans:  
Thermal sensors:  
Environmental specifications  
The following table lists the environmental specifications of the Ethernet  
Routing Switch 8306 chassis.  
Table 9  
Ethernet Routing Switch 8306 environmental specifications  
Environmental specifications  
Operating temperature:  
Storage temperature:  
Operating humidity:  
Storage humidity:  
Operating altitude:  
Storage altitude:  
Free fall/drop:  
0 C to 40 C (32 F to 104 F)  
–25 C to 70 C (–13 F to 158 F)  
85% maximum relative humidity, noncondensing  
95% maximum relative humidity, noncondensing  
3048 m (10,000 ft) maximum  
3048 m (10,000 ft) maximum  
ISO 4180-s, NSTA 1A  
Vibration:  
IEC 68-2-6/34  
Shock/bump:  
IEC 68-2-27-29  
International regulatory requirements  
The following table lists the international regulatory requirements of the  
Ethernet Routing Switch 8306 chassis.  
Table 10  
Ethernet Routing Switch 8306 international regulatory requirements  
International regulatory requirements  
Electromagnetic emissions regulatory requirements:  
Global basis for  
certification:  
CISPR 22-1997 Class A  
U.S.:  
FCC CFR47 Part 15, Subpart B, Class A  
ICES-003, Issue-2, Class A  
Canada:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Ethernet Routing Switch 8301 AC power supply specifications 59  
Table 10  
Ethernet Routing Switch 8306 international regulatory requirements (cont’d.)  
International regulatory requirements  
Europe:  
EN 55022-1998 Class A; EN 61000-3-2/A14,  
EN 61000-3-3 (CE Marking)  
Australia/New  
Zealand:  
AS/NZS 3548:1995, Class A  
Japan:  
VCCI-V3/97.04, Class A  
CNS 13438, Class A  
Taiwan:  
Electromagnetic immunity regulatory requirements:  
Global basis for  
certification:  
CISPR 24:1997  
Europe:  
EN 55024:1998  
Safety regulatory requirements:  
Global basis for  
certification:  
IEC 60950 current edition with all CB member  
deviations  
U.S.:  
UL60950  
Canada:  
Europe:  
CSA 22.2 No. 60950  
EN60950 (CE Marking)  
AS/NZS 3260  
Australia/New  
Zealand:  
Mexico:  
NOM-019-SCFI-1998  
Ethernet Routing Switch 8301 AC power supply specifications  
The following table lists the power specifications for the 8301 AC power  
supply.  
Table 11  
Ethernet Routing Switch 8301 AC power specifications  
AC Input Power Ratings  
Input voltage range (nominal): 100-120 VAC  
200-240 VAC  
12 A  
Input current (nominal):  
Frequency range (nominal):  
Input VA  
16 amperes (A)  
50-60 Hertz (Hz)  
50-60 Hz  
1600 volt-amperes VA 2234 VA  
Input power consumption:  
1584 watts (W)  
2212 W  
Heat dissipation  
(thermal/output):  
1515 British Thermal  
Units (BTU)/hour (hr)  
1508 BTU/hr  
20 ms  
Hold-up time:  
20 milliseconds (ms)  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
60 Technical specifications  
Table 11  
Ethernet Routing Switch 8301 AC power specifications (cont’d.)  
DC Output Power Ratings  
Max. output power  
(combined):  
1140 W (1050 W + 90 1770 W (1680 W + 90  
W fans)  
W fans)  
Non-PoE:  
3.3 VDC @ 150 A  
12 VDC @ 65 A  
50 VDC @ 18 A  
3.3 VDC @ 150 A  
12 VDC @ 65 A  
50 VDC @ 18 A  
PoE:  
Fans:  
12 volts (V)DC @ 7.5 12VDC @ 7.5 A  
A
Note the following information:  
The maximum steady-state output power is limited to a total of 1140  
W for any combination of output voltages/currents at low-line 100-120  
VAC nominal input voltage conditions.  
The maximum steady-state output power is limited to a total of 690 W  
for any combination of output voltages/currents, excluding the 50 VDC  
source at low-line 100-120 VAC nominal input voltage conditions. This  
limitation is required to ensure that there is sufficient PoE power or 450  
W total at this input voltage condition.  
The maximum steady-state output power is limited to a total of 870 W  
for any combination of output voltages/currents, excluding the 50 VDC  
source at high-line 200-240 VAC nominal input voltage conditions. This  
limitation is required to ensure maximum PoE power or 900 W total for  
the 50 VDC source at this input voltage condition.  
To obtain the full output power rating of 1770 W, you must connect the  
power supply to a nominal (200-240 VAC) input voltage source  
Ethernet Routing Switch 8302 AC power supply specifications  
The following table lists the power specifications for the 8302 AC power  
supply.  
Table 12  
Ethernet Routing Switch 8302 AC power specifications  
AC Input Power Ratings  
Input voltage range (nominal):  
Input current (nominal):  
Frequency range (nominal):  
Input VA  
100-120 VAC  
12 A  
200-240 VAC  
9 A  
50-60 Hz  
1192 VA  
1180 W  
50-60 Hz  
1768 VA  
1750 W  
Input power consumption:  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Ethernet Routing Switch 8005DC power supply specifications 61  
Table 12  
Ethernet Routing Switch 8302 AC power specifications (cont’d.)  
Heat dissipation (thermal/output):  
Hold-up time:  
1126 BTU/hr  
20 ms  
1195 BTU/hr  
20 ms  
DC Output Power Ratings  
Max. output power (combined):  
Non-PoE:  
850 W (760 W + 90 W fans) 1400 W (1310 W + 90 W  
fans)  
3.3 VDC @ 150 A  
12 VDC @ 65 A  
50 VDC @ 18 A  
12 VDC @ 7.5 A  
3.3 VDC @ 150 A  
12 VDC @ 65 A  
50 VDC @ 18 A  
12VDC @ 7.5 A  
PoE:  
Fans:  
Note the following information:  
The maximum steady-state output power is limited to a total of 850 W  
for any combination of output voltages/currents at low-line 100-120  
VAC nominal input voltage conditions.  
The maximum steady-state output power is limited to a total of 625 W  
for any combination of output voltages/currents, excluding the 50 VDC  
source at low-line 100-120VAC nominal input voltage conditions. This  
limitation is required to ensure that there is sufficient PoE power or 225  
W total at this input voltage condition.  
The maximum steady-state output power is limited to a total of 950 W  
for any combination of output voltages/currents, excluding the 50 VDC  
source at high-line 200-240VAC nominal input voltage conditions. This  
limitation is required to ensure maximum PoE power or 450 W total for  
the 50 VDC source at this input voltage condition.  
To obtain the full output power rating of 1400 W, you must connect the  
power supply to a nominal (200-240VAC) input voltage source.  
Ethernet Routing Switch 8005DC power supply specifications  
This section provides power ratings for the 8005DC power supply.  
The following table lists the DC input power specifications.  
Parameter  
Specifications  
–48Vdc/–60Vdc  
42 A /34 A  
Input voltage  
Input current (nominal)  
Input VA (maximum)  
Input power consumption  
Heat dissipation (thermal/output)  
1.95 kVA  
1950 W  
1666 Btu/hr  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
62 Technical specifications  
The following table lists the DC output power specifications.  
Parameter  
Specifications  
Output power (maximum)  
Modules  
1462 W (1372 W + 90 W fans)  
3.3 V @ 150 A  
12 V @ 72 A  
Fans  
12 VDC @ 7.5 A/ 24 A peak  
Mean time before failure (MTBF)  
108 803 hr  
(Bellcore TR–332 standard)  
Ethernet Routing Switch 8005DI DC power supply specifications  
This section provides power ratings for the 8005DI DC power supply.  
The following table lists the DC input power specifications.  
Parameter  
Specifications  
–40Vdc/–75Vdc  
48.75A /32.5A  
1.95 kVA  
Input voltage  
Input current  
Input VA (maximum)  
Input power consumption  
Heat dissipation (thermal/output)  
1950 W  
1666 Btu/hr  
The following table lists the DC output power specifications.  
Parameter  
Specifications  
Output power (maximum)  
1462 W continuous, 1660 W peak with forced  
air cooling  
Modules  
3.3 V @ 150 A  
12 V @ 72 A  
Fans  
12 VDC @ 7.5 A/ 24 A peak  
Mean time before failure (MTBF)  
108 803 hr  
(Bellcore TR–332 standard)  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
63  
.
Translations of safety messages  
Class A device caution statement  
CAUTION  
This device is a Class A product. Operation of this equipment  
in a residential area is likely to cause harmful interference, in  
which case users are required to take appropriate measures  
necessary to correct the interference at their own expense.  
CAUTION  
ATTENTION  
Le périphérique est un produit de Classe A. Le fonctionnement  
de cet équipement dans une zone résidentielle risque de causer  
des interférences nuisibles, auquel cas l’utilisateur devra y  
remédier à ses propres frais.  
CAUTION  
ACHTUNG  
Dies ist ein Gerät der Klasse A. Bei Einsatz des Geräts  
in Wohngebieten kann es Störungen des Radio- und  
Fernsehempfangs verursachen. In diesem Fall muss der  
Benutzer alle notwendigen Maßnahmen ergreifen, die  
möglicherweise nötig sind, um die Störungen auf eigene  
Rechnung zu beheben.  
CAUTION  
PRECAUCIÓN  
Este es un producto clase A. El uso de este equipo en áreas  
residenciales puede causar interferencias nocivas, en cuyo  
caso, se requerirá que los usuarios tomen cualquier medida  
necesaria para corregir la interferencia por cuenta propia.  
CAUTION  
CUIDADO  
Este dispositivo é um produto Classe A. Operar este  
equipamento em uma área residencial provavelmente causará  
interferência prejudicial; neste caso, espera-se que os usuários  
tomem as medidas necessárias para corrigir a interferência por  
sua própria conta.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
64 Translations of safety messages  
CAUTION  
ATTENZIONE  
Questo dispositivo è un prodotto di Classe A. Il funzionamento  
di questo apparecchio in aree residenziali potrebbe causare  
interferenze dannose, nel cui caso agli utenti verrà richiesto  
di adottare tutte le misure necessarie per porre rimedio alle  
interferenze a proprie spese.  
Electrostatic discharge caution statement  
CAUTION  
ESD  
To prevent damage from electrostatic discharge, always wear  
an antistatic wrist strap connected to an electrostatic discharge  
(ESD) jack when performing maintenance on this product.  
Ensure that the wrist strap makes contact with your skin.  
CAUTION  
ATTENTION ESD (décharge électrostatique)  
Pour prévenir tout dommage dû à une décharge électrostatique,  
vous devez toujours porter un un bracelet antistatique connecté  
à une prise pour décharge électrostatique (ESD) lors de  
l’exécution d’opérations de maintenance sur ce produit.  
Assurez-vous que le bracelet antistatique est en contact avec  
votre peau.  
CAUTION  
ACHTUNG ESD  
Um Schäden durch elektrostatische Entladung zu verhindern,  
tragen Sie bei der Instandhaltung dieses Produkts immer  
ein antistatisches Band am Handgelenk, das mit einer  
ESD-Buchse verbunden ist. Stellen Sie sicher, dass das Band  
am Handgelenk Kontakt zur Haut hat.  
CAUTION  
PRECAUCIÓN ESD (Descarga electrostática)  
Para prevenir el daño producido por una descarga  
electrostática, use siempre una pulsera antiestática conectada  
a un enchufe de descarga electrostática (ESD) al realizar el  
mantenimiento de este producto. Asegúrese de que la pulsera  
antiestática haga contacto con su piel.  
CAUTION  
CUIDADO ESD  
Para evitar danos com descarga eletrostática, sempre use  
uma pulseira antiestática que esteja conectada a uma tomada  
de descarga eletrostática (ESD) quando estiver realizando a  
manutenção deste produto. Certifique-se de que a pulseira  
esteja em contato com sua pele.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Electrostatic discharge caution statement 65  
CAUTION  
ATTENZIONE ESD  
Per evitare danni derivanti da scariche elettrostatiche, indossare  
sempre un polsino antistatico collegato a una presa di scarico  
elettrostatico (ESD) durante la manutenzione del prodotto.  
Accertarsi che il polsino sia a contatto con la pelle.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
66 Translations of safety messages  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
NN46200-309 01.01 Standard  
16 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Nortel Ethernet Routing Switch 8300  
Installation — Chassis  
Copyright © 2008 Nortel Networks  
All Rights Reserved.  
Printed in Canada and the United States of America  
Release: 4.1  
Publication: NN46200-309  
Document status: Standard  
Document revision: 01.01  
Document release date: 16 June 2008  
To provide feedback or to report a problem in this document, go to www.nortel.com/documentfeedback.  
LEGAL NOTICE  
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing  
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS  
OR IMPLIED. The information and/or products described in this document are subject to change without notice.  
Nortel, the Nortel logo, the Globemark, and Passport are trademarks of Nortel Networks.  
All other trademarks are the property of their respective owners.  
ATTENTION  
For information about the regulatory message, read "Regulatory Information and Safety Precautions"  
in this guide.  
For information about the software license, read "Software license" in this guide.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Dishwasher G 818 SCVI User Manual
Multi Tech Systems Network Router MTCBA C User Manual
NEC Calculator NDA 30103 004 User Manual
NEC Projector LT150 User Manual
Nortec Industries Humidifier GSP Indoor User Manual
OEM Systems Speaker C 10SW User Manual
Onkyo Stereo Receiver TXNR828 User Manual
Oricom Cordless Telephone eco50 User Manual
Oricom Cordless Telephone M120 User Manual
Panasonic Universal Remote EUR511155 User Manual