Nortel Networks Recording Equipment VSN04 User Manual

Network operations systems  
TOPS  
Voice service node  
Log and alarm messages  
Release: VSN04  
Status: Standard  
Version: 03.01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network operations systems  
TOPS  
Voice service node  
Log and alarm messages  
Publication number: 450-1301-511  
Document status: Standard  
Document version: 03.01  
Document release: VSN04  
Date: August 1995  
© Northern Telecom  
All rights reserved.  
TOPS is a trademark of Northern Telecom.  
TOPS VSN log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iii  
Contents  
1. Introduction  
1
Collection and printing log and alarm messages  
TOPS VSN log message format  
Change history  
1
1
4
BCS30  
BCS31  
BCS32  
VSN03  
VSN04  
4
4
4
4
4
2. TOPS VSN log messages  
5
7
13  
19  
39  
41  
47  
3. Common TOPS VSN log messages - 0200  
4. Common TOPS VSN log messages -0201  
5. Common TOPS VSN log messages - 0202  
6. Common TOPS VSN log messages - 0203  
7. Common TOPS VSN log messages - 020A  
8. Common TOPS VSN log messages - 0020  
9. Voice interface resource manager log messages -  
0220  
49  
51  
53  
57  
10. Alarm Subsystem - 8722  
11. ACPE resource manager log messages - 9440  
12. Control link log messages - 9441  
13. Application call processing engine log messages  
- 9442  
14. T1 resource manager log messages - 9443  
15. Locality database log messages - 944E  
16. ACPE Maintenance Position log messages -  
9445  
59  
65  
69  
73  
75  
77  
17. Prompt manager log messages - 9451  
18. Suppressed and Thresholded Logs  
Suppressed Logs  
Thresholding Logs  
19. DMS notices  
77  
79  
81  
83  
20. Abbreviations  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
1. Introduction  
Collection and printing log and alarm messages  
Logs and Alarms are collected for TOPS Voice Service Node (VSN) using the  
log and alarm subsystem installed in base TOPS VSN software. The same  
subsystem is responsible for creating log and alarm reports. These are stored  
temporarily on the TOPS VSN and can be sent to a printer or to a terminal for  
continuous display. TOPS VSN uses a dedicated printer to report its log  
messages.  
Predefined log and alarm configuration datafill is delivered to the operating  
company as part of the TOPS VSN installation tapes.  
TOPS VSN log message format  
A typical TOPS VSN log or alarm message is shown below in figure 1-1. Its  
identifying information is printed on one or two lines, and is followed by the  
message.  
Figure 1-1  
Sample TOPS VSN log/alarm message  
Severity of  
Occurrance  
Subsystem  
Number  
Report  
Number  
Log Message  
Number  
Date and Time of  
Generation Locally  
*Minor LAN_NAME Subsystem=8720, Report no=0003, Error no=0002, 88 03 22 13:36  
PRU state Change: Cabinet 1 Slot 14 Unit#85BC Configuration #0000 FAULTY  
Reporting PRU is Logger  
Other PRU is Unspecified RU.  
dwg 1301-511-1  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Introduction  
Header Information For TOPS VSN Log Messages.  
Identifying information, also known as header information, uniquely identifies  
each log and alarm message. The header of every log or alarm message  
generated by TOPS VSN contains the following:  
(a) Date and Time. The date and time are displayed in the upper left of the  
message. The format of the date is yymmdd, and the format of the time is  
hh:mm.  
(b) Severity. Each log message specifies the severity of the event it is  
reporting. The following terms or values are used to indicate severity:  
*C Critical  
Severity 1  
Severity 2  
Severity 3  
Logs with this severity generate critical  
alarms. These logs and alarms are the result  
of catastrophic failures such as power  
failures.  
**  
*
Major  
Minor  
Logs with this severity generate major  
alarms. These logs and alarms are the result  
serious failures such as PRUs being unable  
to initialize.  
Logs with this severity generate minor  
alarms. These alarms are used to flag  
problems that need either a visual or  
audible display at the TOPS VSN site. An  
example of a problem that would cause a  
minor alarm is an incorrect table entry.  
GEvent  
GError  
LEvent  
LError  
Severity 4  
Severity 5  
Severity 6  
Severity 7  
These are intermediate severity ratings. An  
event is a happening that does not effect  
service. The event is simply logged for the  
record. An error is also considered non-  
service affecting. It is an isolated error  
condition caused by the system, for  
example, a single lost call.  
Warning/  
Trouble  
Severity 8  
Severity 9  
This log severity indicates a warning.  
Status  
This log severity reports the status of a  
particular software or hardware unit. The  
percentage of disk space used is an  
example of a log with status severity.  
Progress  
Severity 10  
Log reports the progress of an event.  
Severity 11-13 These severity ratings are not defined for  
TOPS VSN.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction 3  
Status 14  
Status 14  
Used for login/logout security related  
events. This status is now used by all logs  
generated from two DVS subsystems  
(8029 System Administration (Report #1  
only, and 8039 Security Agent Sub-PRU).  
The logs produced from these two  
subsystems identify logins, logouts,  
changes to USERIDs and Admin objects.  
Information  
Status 15  
This log severity is used for informational  
purposes only.  
(c) Subsystem Number. The subsystem number is a four-digit hexadecimal  
number that identifies a message subsystem. For example, the subsystem  
number for TOPS VSN common logs is 0200 to 020A. Each program  
resource unit (PRU) that generates logs has its own subsystem; the common  
logs are shared by all TOPS VSN PRUs.  
The following list identifies the number associated with each PRU:  
0200 - Common Logs - Run Errors  
0201 - Common Logs - Tasking Errors  
0202 - Common Logs - I/O Errors  
0203 - Common Logs - VTP Errors  
020A - TOPS VSN Common Logs  
0220 - VI Resource Manager Logs  
8722 - Alarms PRU  
9440 - ACPE Resource Manager Logs  
9441 - Control Link Logs  
9442 - ACPE Logs + ACPE Executor  
9443 - T1 Resource Manager Logs  
9445 - ACPE Maintenance Position  
(d) Report Number. Report numbers are hexadecimal numbers. They identify  
the group or category within the subsystem file the message belongs to. For  
TOPS VSN common log messages, the following numbering convention  
applies:  
Number  
0000  
Type  
Nonspecified error types  
Run errors  
0001  
0002  
Tasking errors  
IO errors  
0003  
(e) Error Number. Error numbers are hexadecimal numbers. They identify the  
specific error condition within each report number grouping.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Introduction  
Change history  
This section summarizes the important changes that affect this publication.  
They are arranged under the heading of the appropriate Batch Change  
Supplement (BCS) release.  
BCS30  
The presentation of this publication has been changed.  
The following changes to the TOPS VSN application were made by BCS30:  
introduction of log messages for the locality database  
introduction of log messages for the prompt manager  
addition of an abbreviations list  
introduction of log messages for the support of locality call processing  
BCS31  
BCS32  
This Document has been reissued as part of the BCS31 release.  
This document has been revised to include several new alarms in the 8722  
subsystem and to include a list of suppressed and thresholded logs.  
VSN03 - Version 02.01  
This document has been revised to include several new alarm and log messages.  
VSN04 - Version 03.01  
This document has been revised to include a new log message.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
2. TOPS VSN log messages  
TOPS VSN log messages are separated into two groups: common logs, and  
PRU-specific logs. Each group generates logs from a single subsystem (in most  
cases a subsystem is defined by a PRU). This Publication uses separate tables for  
each subsystem that generates logs.  
The first six tables list logs that are common to TOPS VSN as a whole. These  
logs are generated from base software but have specific application to TOPS  
VSN. With these logs there is no one-to-one correspondence between subsystem  
and PRU. The remaining tables list logs by software (PRU) subsystem. A  
complete list of logs generated from base software is given in Publication  
450-1301-511.  
Accompanying each log entry is a definition and a description of the action the  
user must take to respond to the log. This Publication contains the following log  
sections:  
3. lists messages for base run errors.  
4. lists messages for base tasking errors.  
5. lists messages for base IO errors.  
6. lists messages for base VTP errors.  
7. lists messages for TOPS VSN common logs.  
8. lists base maintenance notices.  
9. lists messages for VI resource manager errors.  
10. lists messages for the Alars PRU.  
11. lists messages for ACPE resource manager errors.  
12. lists messages for datalink errors.  
13. lists messages for ACPE errors.  
14. lists messages for T1 resource manager errors.  
15. lists messages for the Locality Database.  
16. lists messages for the Prompt Manager.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 DNC Logs TOPS VSN Log Messages  
The following messages are the complete, or raw messages. The log service may  
select only certain items from the lists shown for each message, depending on  
the nature of the event.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
3. Common TOPS VSN log  
messages - 0200  
0001/0000  
0001/0001  
0001/0002  
0001/0003  
0001/0004  
Message: [PRU_name] has encountered a bus error. This is an  
unrecoverable error and the SRU where this PRU resides should be rebooted.  
Description: The software task failed because of a hardware error. If the  
PRU declares itself faulty then the log subsystem detects the faulty condition  
and raises an alarm.  
Action: Reboot the SRU. If the error occurs more than once a week replace  
the SRU. Record all action taken.  
Message: [PRU_name] has encountered a divided by zero run error. This is  
an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed because it encountered a divide by  
zero operation. The PRU may declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
Message: [PRU_name] has encountered a dereferencing of an odd address  
run error. This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is in  
a faulty state, document the problem, restart the PRU, and then contact NT.  
Message: [PRU_name] has encountered an illegal user instruction run error.  
This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is in  
the faulty state, document the problem, restart the PRU, and then contact NT.  
Message: [PRU_name] has encountered a value range error. This is an  
unrecoverable error and the PRU should be rebooted.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 Common TOPS VSN log messages (0200)  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0005  
0001/0006  
Message: [PRU_name] has encountered a stack overflow condition. This is  
an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is in  
the faulty state, document the problem, restart the PRU, and then contact NT.  
Message: [PRU_name] has encountered a privilege violation error. This is an  
unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0007  
0001/0008  
Message: [PRU_name], Filler log. This log should not occur as defined in  
Errordefs.  
Description: The software task failed due to a software error.  
Action: Retain all information regarding the problem, and then contact NT.  
Message: [PRU_name] has no buffer pools associated with the task. This is  
an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0009  
Message: [PRU_name] can not allocate control blocks. This is an  
unrecoverable error and the PRU should be rebooted. If rebooting the PRU  
does not solve the problem, reboot the SRU.  
Description: The software task failed because it could not allocate control  
blocks. Control blocks are required for communication between PRUs. The  
PRU may declare itself faulty or recreate the task. If the PRU declares itself  
faulty then the log subsystem detects the faulty condition and raises an alarm.  
Action: Reboot the PRU. If this action does not correct the problem, then  
reboot the SRU. If the error occurs more than once a week replace the SRU.  
Document the problem and record all action taken.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0200)  
DNC Logs 9  
0001/000A  
Message: [PRU_name] encountered a segment or mapper error. This is an  
unrecoverable error and the PRU should be rebooted. If rebooting the PRU  
does not solve the problem, reboot the SRU.  
Description: The software task failed because it encountered a segment or  
mapping error. The PRU may declare itself faulty or recreate the task. If the  
PRU declares itself faulty then the log subsystem detects the faulty condition  
and raises an alarm.  
Action: Reboot the PRU. If this action does not correct the problem, then  
reboot the SRU. If the error occurs more than once a week replace the SRU.  
Document the problem and record all action taken.  
0001/000B  
Message: [PRU_name] has been in a critical region too long. This is an  
unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/000C  
Message: [PRU_name] has encountered a parity error. This is an  
unrecoverable error and the SRU should have diagnostics run.  
Description: The software task failed because of a parity error. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: Run diagnostics on the SRU containing the PRU. To do this take all  
other PRUs out of service first. If diagnostics fail, replace the SRU. If  
diagnostics do not detect an error but the problem persists, replace the SRU.  
Document the problem and record all action taken.  
0001/000D  
Message: [PRU_name] encountered a kernel error. This is an unrecoverable  
error and the SRU should be rebooted.  
Description: The software task failed because the kernel of the SRU in which  
the PRU is operating has encountered an unexpected state. The PRU may  
declare itself faulty or recreate the task. If the PRU declares itself faulty then the  
log subsystem detects the faulty condition and raises an alarm.  
Action: Reboot the SRU. If the error occurs more than once a week replace  
the SRU. Document the problem and record all action taken.  
0001/000E  
Message: [PRU_name] has encountered a floating point math error. This is  
an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a reference error. The PRU may  
declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 Common TOPS VSN log messages (0200)  
0001/000F  
0001/0010  
0001/0011  
Message: [PRU_name] has encountered a nil pointer reference run error.  
This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a reference error. The PRU may  
declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
Message: [PRU_name] has encountered a run error when performing a set  
operation. This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed during a set operation. The PRU may  
declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
Message: [PRU_name] has encountered a run error while performing a math  
operation. Specifically, the error occurred when performing a conversion of a  
long integer to a short integer. This is an unrecoverable error and the PRU  
should be rebooted.  
Description: The software task failed because the integer was to large to be  
converted to a short integer. The PRU may declare itself faulty or recreate the  
task. If the PRU declares itself faulty then the log subsystem detects the faulty  
condition and raises an alarm.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0012  
0001/0013  
Message: [PRU_name] has encountered a divide by zero run error. This is an  
unrecoverable error.  
Description: The software task failed because of a long divide by zero  
operation. The PRU may declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
Message: [PRU_name] has encountered an overflow run error when  
performing multiplication. This is an unrecoverable error and the PRU should  
be rebooted.  
Description: The software task failed because a multiplication operation was  
too large and overflowed. The PRU may declare itself faulty or recreate the  
task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0014  
Message: [PRU_name] has attempted to exit a procedure not directly called.  
This is an unrecoverable error and the PRU should be rebooted.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0200)  
DNC Logs 11  
Description: The software task failed because it tried to perform an exit  
command from a procedure it was not currently executing. The PRU may  
declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0015  
0001/0016  
Message: [PRU_name] encountered a mini-task error. This is an  
unrecoverable error and the PRU should be rebooted.  
Description: The software task failed due to a software error. The PRU may  
declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
Message: [PRU_name] was passed input to a transcendental function that  
was negative. This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed because a negative value was used for  
a transcendental function. Transcendental function values must be positive.  
The PRU may declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
0001/0017  
Message: [PRU_name] encountered an error associated with IEEE real  
numbers. This is an unrecoverable error and the PRU should be rebooted.  
Description: The software task failed because of an illegal IEEE real number  
operation. The PRU may declare itself faulty or recreate the task.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart the PRU, and then contact  
NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
4. Common TOPS VSN log  
messages -0201  
0002/0000  
Message: [PRU_name] has successfully communicated with [Other  
PRU_name]. (No error detected.)  
Description: The named PRUs are communicating.  
Action: No action is required.  
0002/0001  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. This means the message was not accepted after a  
timeout value.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message after a specified time interval. It is  
the responsibility of the sending PRU to recover from the error by resending  
the message, or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0002  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. This means the message was not accepted after a  
timeout value.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message after a specified time interval. It is  
the responsibility of the sending PRU to recover from the error by resending  
the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0003  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. This means the message was not accepted after a  
timeout value.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message after a specified time interval. It is  
the responsibility of the sending PRU to recover from the error by resending  
the message or to declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14 Common TOPS VSN log messages (0201)  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0004  
0002/0005  
0002/0006  
0002/0007  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. Either a bad control block handler or a bad taskID  
could cause such an error.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message. It is the responsibility of the  
sending PRU to recover from the error by resending the message or to declare  
itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The receiver of the message [Receiving_PRU_  
name] is probable cause of error.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message. It is the responsibility of the  
sending PRU to recover from the error by resending the message or to declare  
itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. This means the message was not accepted after a  
timeout value.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message after a specified time interval. It is  
the responsibility of the sending PRU to recover from the error by resending  
the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The sender encountered an invalid wait time.  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message after a specified time interval. It is  
the responsibility of the sending PRU to recover from the error by resending  
the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0201)  
DNC Logs 15  
0002/0008  
Message: [PRU_NAME] was trying to communicate with [PRU_NAME] but  
could not.  
->TaskResult=<task_result_num>  
"Diagnostic String1"  
"Diagnostic String2"  
Description: This log indicates that a communication error has occurred.  
Action may be required, depending on the state of the PRU(s). If the PRU(s) are  
in a "working" state, it can be assumed that the software recovered from the  
error and no further action is required. If one or both of the PRUs are "faulty" or if  
the problem persists, reboot the "faulty" PRU(s).  
Action: If the problem persists, retain all of the information regarding the  
problem and contact your NT representative.  
0002/0009  
Message: [Sending_PRU_name] was trying to initiate a task but could not.  
Description: The sending PRU could not initiate a task. It is the responsibility  
of this PRU to recover from the error by resending the message or to declare  
itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem and reboot the PRU. If the problem  
persists reboot the SRU in which the PRU resides. Document the problem,  
record all action taken , and then call NT.  
0002/000F  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The sender [Sending_PRU_name] did not have a  
communication pool available OR there was an invalid "MakePool".  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0011  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The sender [Sending_PRU_name] encountered  
an illegal operation in its mini task.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0015  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. Depending on the type of communication method  
used either [Receiving_PRU_ name] or [Sending_PRU_name] does not have  
enough communication buffers available.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16 Common TOPS VSN log messages (0201)  
Description: The sending PRU could not communicate with the receiving  
PRU. The latter did not accept the message. It is the responsibility of the  
sending PRU to recover from the error by resending the message or to declare  
itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0016  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The sender [Sending_PRU_ name] could not  
transmit to the network.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, restart the sending PRU. If the problem persists, then  
reboot the entire machine. Document the problem, record all action taken, and  
then contact NT.  
0002/0017  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The sender [Sending_PRU_ name] encountered a  
stack overflow.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then restart the sending PRU. If the problem persists, then  
reboot the SRU in which the PRU resides. Document the problem, record all  
action taken, and then contact NT.  
0002/0018  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The information being passed within the  
communication packet is invalid.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
0002/0019  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The entry definition in [Receiving_PRU_name]  
does not match what [Sending_PRU_ name] expects. User action is required.  
Description: The sending PRU could not communicate with the receiving  
PRU because the software version in each were not the same.  
Action: The user must reinstall both PRUs from the load tape. If the problem  
persists, then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0201)  
DNC Logs 17  
0002/001A  
0002/001B  
0002/001C  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The entry definition in [Sending_PRU_name] was  
not found, OR push/pull was invoked when not in entry. User action is  
required.  
Description: The sending PRU could not communicate with the receiving  
PRU because the software version in each were not the same.  
Action: The user must reinstall both PRUs from the load tape. If the problem  
persists, then contact NT.  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The result was a communication failure.  
Description: The sending PRU can not communicate with the receiving PRU  
because the receiving PRU is not there. It is the responsibility of the sending  
PRU to recover from the error or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, document the problem, restart both sending and receiving  
PRUs, and then contact NT.  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The result was that the location address of the  
receiver was invalid.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then document the problem, and restart both sending and  
receiving PRUs. If necessary, restart the SRUs in which both PRUs reside.  
Record all action taken, and then contact NT.  
0002/001D  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The result was an interval timer error.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then document the problem, and restart both sending and  
receiving PRUs. If necessary, restart the SRUs in which both PRUs reside.  
Record all action taken, and then contact NT.  
0002/001E  
Message: [Sending_PRU_name] was trying to communicate with [Receiving_  
PRU_name] but could not. The problem is the sender [Sending_PRU_name]  
could not obtain control blocks. User action is required.  
Description: The sending PRU could not communicate with the receiving  
PRU. It is the responsibility of the sending PRU to recover from the error by  
resending the message or to declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18 Common TOPS VSN log messages (0201)  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then document the problem, and restart both sending and  
receiving PRUs. If necessary, restart the SRUs in which both PRUs reside.  
Record all action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
5. Common TOPS VSN log  
messages - 0202  
0003/0000  
Message: [PRU_name] successfully performed an IO operation on pathname  
[file/directory_pathname].  
Description: The PRU successfully completed an IO operation.  
Action: No action required.  
0003/0001  
Message: [PRU_name] received an IO error (Mixed_Access) on path  
[file/directory_path name]. The "localized SRU" error was the result of mixing IO  
types, for example (Readln and blockreads).  
Description: The PRU encountered an error during an IO operation on the  
file or directory. It is the responsibility of the PRU performing the operation to  
recover from the error and to retry the operation. If it is unable to do so, then it  
can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, the  
corrective action taken, and then contact NT.  
0003/0002  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of reaching a resource limit.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. It is the responsibility of the PRU performing the operation to  
recover from the error and to retry the operation. If it is unable to do so, then it  
can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If the PRU is still faulty, then reboot  
the SRU in which the PRU resides. If all reboot operations are unsuccessful,  
then reboot the whole system. Document the problem, the corrective action  
taken, and then contact NT.  
0003/0014  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of trying to write an illegal character.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20 Common TOPS VSN log messages (0202)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. It is the responsibility of the PRU performing the operation to  
recover from the error and to retry the operation. If it is unable to do so, then it  
can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, the  
corrective action taken, and then contact NT.  
0003/001E  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of an out of bounds operation.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, the  
corrective action taken, and then contact NT.  
0003/0028  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of performing an I/O operation on a file that was  
not opened.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, or if the problem persists, then reboot the PRU. If this action  
doesn't correct the problem, reboot the SRU. If the PRU is still faulty, then  
reboot the entire system. Document the problem, record all action taken, and  
then contact NT.  
0003/0029  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of performing an open operation on a file that  
was already opened.  
Description: The PRU encountered an error during an IO (open) operation  
on the file or directory. The operation was not performed because it did not  
make its way to the server. The error is in the SRU where the PRU resides. It is  
the responsibility of the PRU performing the operation to recover from the error  
and to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, the  
corrective action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 21  
0003/002A  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of trying to save the file to disk, but the file was  
not opened for "writable" access.  
Description: The PRU encountered an error during an IO operation such as,  
open, read, or write, on the file or directory. The operation was not performed  
because it did not make its way to the server. The error is in the SRU where the  
PRU resides. It is the responsibility of the PRU performing the operation to  
recover from the error and to retry the operation. If it is unable to do so, then it  
can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, the  
corrective action taken, and then contact NT.  
0003/002B  
0003/002C  
0003/002D  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of performing an illegal seek operation.  
Description: The PRU encountered an error during an IO operation such as,  
open, read or write, on the file or directory. The operation was not performed  
because it did not make its way to the server. The error is in the SRU where the  
PRU resides. It is the responsibility of the PRU performing the operation to  
recover from the error and to retry the operation. If it is unable to do so, then it  
can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of performing an operation on a file set using a  
bad identifier for the file set.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error on path [file/directory_path  
name]. The error was the result of performing an I/O operation, but the server  
that was referenced [first_component_of_pathname], was not found.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22 Common TOPS VSN log messages (0202)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/002E  
0003/002F  
0003/0030  
Message: [PRU_name] received an IO error (Across_File_System) on path  
[file/directory_path name]. The error was the result of performing an I/O  
operation across file systems. Some commands are not supported.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Already_Logged_On) on path  
[file/directory_path name]. The error was the result of logging into a server that  
is already logged into.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Client_Resource_Limit) on path  
[file/directory_path name]. The error was the result of reaching some limit local  
to the SRU where the PRU [PRU_name] resides.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. Probable cause is one or more open files. This error is in the  
SRU where the PRU resides. It is the responsibility of the PRU performing the  
operation to recover from the error and to retry the operation. If it is unable to  
do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 23  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0031  
Message: [PRU_name] received an IO error (Value_Overflow) on path  
[file/directory_path name]. The error was the result of overflowing a particular  
field.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0064  
Message: [PRU_name] received an IO error (Mismatch_In_Interface) on path  
[file/directory_path name]. The "server" error was the result of having old and  
new versions of kernel/file server code. User action is required.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed because it did not make its  
way to the server. This error is in the SRU where the PRU resides. It is the  
responsibility of the PRU performing the operation to recover from the error and  
to retry the operation. If it is unable to do so, then it can declare itself faulty.  
Action: Load compatible software loads on each SRU and the file server(s).  
Reboot the system. Document the problem, record all action taken, and then  
contact NT.  
0003/0065  
Message: [PRU_name] received an IO error (Bad_Pathname) on path  
[file/directory_path name]. The "server" error was the result of specific illegal  
characters, or bad length in the pathname.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/0066  
Message: [PRU_name] received an IO error (File_Not_Found) on path  
[file/directory_path name]. The "server" error was the result of not being able to  
find the specified file (or path) on the requested server.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24 Common TOPS VSN log messages (0202)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/0067  
0003/0068  
0003/0069  
Message: [PRU_name] received an IO error (Cannot_Create) on path  
[file/directory_path name]. The "server" error was the result of not being able to  
create the specified file (or path).  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Duplicate_Name) on path  
[file/directory_path name]. The "server" error was the result of attempting to  
create a file (or directory) when the entity already exits.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Address) on path  
[file/directory_path name]. The "server" error was the result of specifying a bad  
address.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 25  
0003/006A  
Message: [PRU_name] received an IO error (Outside_File_Boundaries) on  
path [file/directory_path name]. The "server" error was the result of attempting  
an IO operation outside the boundaries of the file. (Accessing beyond the end  
of file).  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/006B  
Message: [PRU_name] received an IO error (Mode_Conflict) on path  
[file/directory_path name]. The "server" error was the result of a mode conflict  
error. (i.e.. a file was opened for write mode and someone else already had the  
file opened in the write mode.)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/006C  
Message: [PRU_name] received an IO error (Bad_Obj_Type) on path  
[file/directory_path name]. The "server" error was the result of specifying a bad  
object type.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/006D  
Message: [PRU_name] received an IO error (Access_Denied) on path  
[file/directory_path name]. The "server" error was the result of an access  
denied operation. (i.e.. The user does not have access rights to the file.)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26 Common TOPS VSN log messages (0202)  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/006E  
0003/006F  
0003/0070  
Message: [PRU_name] received an IO error (Invalid_Password) on path  
[file/directory_path name]. The "server" error was the result of an invalid  
password specified.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Command_Not_Supported) on  
path [file/directory_path name]. The "server" error was the result of specifying a  
command that is not supported.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Device_Offline) on path  
[file/directory_path name]. The "server" error was the result of attempting to  
access a device that is offline.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: Put the required device on line or specify an alternate online  
device. If the PRU is in the working state, no action is required. If the PRU is in  
the faulty state, then reboot the PRU. If the problem persists, then reboot the  
server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/0071  
Message: [PRU_name] received an IO error (Server_Resource_Limit) on  
path [file/directory_path name]. The "server" error was the result of reaching a  
server resource limit, probably too many files open.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 27  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: Close all files that do not need to be open. If the PRU is in the  
working state, no action is required. If the PRU is in the faulty state, then reboot  
the PRU. If the problem persists, then reboot the server which handles the IO  
operation. If neither reboot operations are successful, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0072  
Message: [PRU_name] received an IO error (Parity_Error) on path  
[file/directory_path name]. The "server" error was the result of a parity error in  
reading data from the server.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU and the file server. If the problem  
persists, replace the file server SRU and if necessary, the disk. Document the  
problem, record all action taken, and then contact NT.  
0003/0073  
Message: [PRU_name] received an IO error (Disk_Write_Protected) on path  
[file/directory_path name]. The "server" error was the result of trying to write to  
a disk that is write protected. Access SAS utilities and unprotect the server. If it  
is the prime disk, use FSPATCH.  
Description: The PRU encountered an error during an IO (write) operation  
on the file or directory. The operation was not performed. It is the responsibility  
of the PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: Reset the write protect flag of the file server. If the PRU is in the  
working state, no further action is required. If the PRU is in the faulty state, then  
reboot the PRU and the file server. If the problem persists, replace the file  
server SRU and if necessary, the disk. Document the problem, record all action  
taken, and then contact NT.  
0003/0074  
Message: [PRU_name] received an IO error (No_Directory) on path  
[file/directory_path name]. The "server" error was the result of performing an  
operation on a directory that does not exit.  
Description: The PRU encountered an error during an IO operation trying to  
access a directory. The operation was not performed. It is the responsibility of  
the PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28 Common TOPS VSN log messages (0202)  
Message: [PRU_name] received an IO error (Object_Not_Writable) on path  
0003/0075  
0003/0076  
0003/0077  
0003/0078  
[file/directory_path name]. The "server" error was the result of performing a  
write operation on an object (or file) that can not be written to.  
Description: The PRU encountered an error during an IO (write) operation  
on the file or object. The operation was not performed. It is the responsibility of  
the PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Access_Mode) on path  
[file/directory_path name]. The "server" error was the result of an illegal access  
specification in pathname.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Remote_Pointer) on path  
[file/directory_path name]. The "server" error was the result of using a bad  
remote pointer.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Transaction_Timeout) on path  
[file/directory_path name]. The "server" error was the result of a timeout that  
occurred on a close/commit of a transactional file set.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 29  
Action:  
If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/0079  
0003/0082  
0003/0083  
0003/0084  
Message: [PRU_name] received an IO error (Date_Noset) on path  
[file/directory_path name]. The error was the result of attempting a file commit  
with no time server on node.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Directory) on path  
[file/directory_path name]. The error was the result of not being able to  
recognize the directory structure on the floppy.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Too_Many_Files_On_Dir) on  
path [file/directory_path name]. The error was the result of an overrun on UCSD  
limit of 77 files per floppy.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: Remove unwanted files from the floppy. If the PRU is in the working  
state, no action is required. If the PRU is in the faulty state, then reboot the  
PRU. If the problem persists, then reboot the server which handles the IO  
operation. If neither reboot operations are successful, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (No_Room_On_Vol) on path  
[file/directory_path name]. The error was the result of the disk being full.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 Common TOPS VSN log messages (0202)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
0003/0085  
0003/0086  
0003/008C  
Message: [PRU_name] received an IO error (New_Volume_Mounted) on  
path [file/directory_path name]. The error was the result of a new volume being  
mounted.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Timeout_On_Vol) on path  
[file/directory_path name]. The error was the result of a server communication  
problem.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Serious_Error_Level) on path  
[file/directory_path name].  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 31  
0003/0094  
0003/0095  
0003/0096  
0003/0097  
Message: [PRU_name] received an IO error (Bad_Comm_Addr) on path  
[file/directory_path name]. The error was the result of specifying an invalid site  
address.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If neither reboot operations are  
successful, then reboot the whole system. Document the problem, record all  
action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Comm_Msg) on path  
[file/directory_path name]. The error was the result of a protocol error between  
communication servers.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Comm_Link_Failure) on path  
[file/directory_path name]. The error was the result of failure in communications  
between sites.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Remote_Site_Failure) on path  
[file/directory_path name]. The error was the result of a failure of the server at  
the remote site.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32 Common TOPS VSN log messages (0202)  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0098  
Message: [PRU_name] received an IO error (Bad_File) on path  
[file/directory_path name]. The error was the result of file identifier not  
recognized by the server.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0099  
Message: [PRU_name] received an IO error (Consistency_Check) on path  
[file/directory_path name]. The error was the result of data on the disk is not  
what the file system thinks is on the disk.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: Reformat the disk. Document the problem, record all action taken,  
and then contact NT.  
0003/009A  
Message: [PRU_name] received an IO error (Bad_Transaction_ID) on path  
[file/directory_path name]. The error was the result of an invalid file set  
transaction identifier.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/009B  
Message: [PRU_name] received an IO error (Bad_Volume_ID) on path  
[file/directory_path name]. The error was the result of the specified volume  
identifier for the fid (file identifier) is for this server.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 33  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/009C  
0003/009D  
0003/009E  
0003/009F  
Message: [PRU_name] received an IO error (Spares_Not_Zero) on path  
[file/directory_path name]. The error was the result of the "spares" field input is  
not zero.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Uobj_Type) on path  
[file/directory_path name]. The error was the result of an invalid Unix Object  
type specified.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (File_Exists_Already) on path  
[file/directory_path name]. The error was the result of specifying an exclusive  
option set but the file already exists.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_SCR_Pathname) on path  
[file/directory_path name]. The error was the result of invalid source pathname  
specified.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34 Common TOPS VSN log messages (0202)  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0100  
0003/0101  
0003/0102  
Message: [PRU_name] received an IO error (Illegal_Parameter) on path  
[file/directory_path name]. The error was the result of an illegal parameter  
submitted to FileOperating System interface.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Dest_Pathname) on path  
[file/directory_path name]. The error was the result of specifying a bad  
destination pathname.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Dest_VolumeID) on path  
[file/directory_path name]. The error was the result of specifying a volume ID of  
the destination fid (file identifier) is not for this server.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 35  
0003/0103  
0003/0096  
0003/0105  
0003/0106  
Message: [PRU_name] received an IO error (Bad_Parameter) on path  
[file/directory_path name]. The error was the result of specifying an invalid input  
parameter.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (New_PSWD_Invalid) on path  
[file/directory_path name]. The error was the result of specifying a bad  
password.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Vol_Control_Param) on  
path [file/directory_path name]. The error was the result of specifying a bad  
volume control parameter.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Agent_ID) on path  
[file/directory_path name]. The error was the result of an agent_ID on logout  
being invalid.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36 Common TOPS VSN log messages (0202)  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0107  
0003/0108  
0003/0096  
0003/010A  
Message: [PRU_name] received an IO error (No_Dir_Blk_Delete) on path  
[file/directory_path name]. The error was the result of no standard delete of  
directory blocks.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_Key) on path  
[file/directory_path name]. The error was the result of the instance key handed  
in is invalid.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (FS_Read_Error) on path  
[file/directory_path name]. The error was the result of a Read Error occurring in  
user data.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (FS_Write_Error) on path  
[file/directory_path name]. The error was the result of a Write Error occurring in  
user data.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (0202)  
DNC Logs 37  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/010B  
0003/010C  
0003/010D  
Message: [PRU_name] received an IO error (Bad_SFS_Task_ID) on path  
[file/directory_path name]. The error was the result of the agent or object  
identifier which does not exist.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_CMD_Length) on path  
[file/directory_path name]. The error was the result of the length of the File  
Operating System command being incorrect.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
Message: [PRU_name] received an IO error (Bad_SRC_Volume_ID) on path  
[file/directory_path name]. The error was the result of specifying a volume_ID of  
source fid (file identifier) not for this server.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38 Common TOPS VSN log messages (0202)  
0003/010E Message: [PRU_name] received an IO error (PERM_Denied) on path  
[file/directory_path name]. The error was the result of permission denied.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
0003/0129  
Message: [PRU_name] received an IO error (Special_File) on path  
[file/directory_path name]. The error was the result of a SFS special file for  
UNIX.  
Description: The PRU encountered an error during an IO operation on the  
file or directory. The operation was not performed. It is the responsibility of the  
PRU performing the operation to recover from the error and to retry the  
operation. If it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. If the problem persists, then reboot  
the server which handles the IO operation. If this action doesn't correct the  
problem, then reboot the SRU. If the PRU is still faulty, then reboot the whole  
system. Document the problem, record all action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
6. Common TOPS VSN log  
messages - 0203  
0001/0000  
Message: [PRU_name] encountered a VTP error [decimal]. [Two 80 character  
lines of optional data.]  
Description: The PRU encountered an communication error. The  
communication operation was not performed. It is the responsibility of the PRU  
performing the operation to recover from the error and to retry the operation. If  
it is unable to do so, then it can declare itself faulty.  
Action: If the PRU is in the working state, no action is required. If the PRU is  
in the faulty state, then reboot the PRU. Document the problem, record all  
action taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
7. Common TOPS VSN log  
messages - 020A  
0001/0000  
Message: [PRU_name] could not obtain sufficient memory to operate. User  
action is required. [Two 80 character lines of optional data.]  
Description: The PRU could not find enough memory to perform a function  
or to initialize.  
Action: The user should make sure that there are no PRUs defined in the  
application processor that do not need to be there. Document the problem,  
record all action taken, and then contact NT.  
0001/0001  
Message: [PRU_name] could not obtained sufficient memory to obtain  
communication buffer pools. The number of buffers required = [decimal]. The  
size of buffers required = [decimal]. The buffer pool identifier = [name]. User  
action is required. [Two 80 character lines of optional data.]  
Description: The PRU could not find found enough memory to obtain  
communication buffers.  
Action: The user should make sure that there are no PRUs defined in the  
application processor that do not need to be there. Document the problem,  
record all action taken, and then contact NT.  
0001/0002  
0001/0003  
Message: [PRU_name] could not add buffer memory pools to task. [Two 80  
character lines of optional data.]  
Description: The PRU had trouble interacting with the memory manager.  
The PRU should declare itself faulty.  
Action: Document the problem, and then contact NT.  
Message: [PRU_name] tried to register [name] with the name server but  
failed. [Two 80 character lines of optional data.]  
Description: The PRU could not register its name with the name server  
facility. No other PRU will be able to find this PRU through the name server  
facility. The PRU does not necessarily have to declare itself faulty; it can  
communicate using other means. This log indicates trouble with the name  
server.  
Action: Reboot the PRU. If this action is unsuccessful, then reboot the SRU  
in which the name server resides. Document the problem, record all action  
taken, and then contact NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42 Common TOPS VSN log messages (020A)  
0001/0004  
Message: [PRU_name] tried to locate [name] with the name server but failed.  
[Two 80 character lines of optional data.]  
Description: The PRU could not find the name of the PRU or task it was  
trying to locate using the name server facility. The PRU does not necessarily  
have to declare itself faulty; it can communicate using other means. This log  
indicates one of two problems: trouble with the name server, or that the PRU or  
task does not exist.  
Action: If the entity exists make sure that it's state is "working". If the PRU or  
task does exist, reboot it. If this action is unsuccessful, then reboot the SRU in  
which the PRU resides. If the problem persists reboot the entire machine.  
Document the problem, record all action taken, and then contact NT.  
0001/0005  
Message: [PRU_name] tried to register with the DVS Resource Manager and  
failed. Return code = [defined_below]. [Two 80 character lines of optional  
data.]  
Description: When the PRU tries to register its name with the DVS Resource  
Manager, a return code indicates the nature of the failure. Return codes are:  
invalid address or not present, or Reg-Operation parameter is out of range.  
Action: When the return code indicates failure to communicate with the DVS  
Resource Manager, reboot the PRU. If this action is unsuccessful, then reboot  
the entire machine. Document the problem, and record all action taken. If the  
problem persists, then contact NT.  
0001/0006  
Message: [PRU_name] tried to perform an "rm_Request" with the DVS  
Resource Manager and failed. Return code = [DVS_code]. [Two 80 character  
lines of optional data.]  
Description: The PRU tried to perform a request with the DVS Resource  
Manager but failed. The return code indicates the reason.  
Action: When the return code indicates failure to communicate with the DVS  
Resource Manager, then reboot the PRU. If this action is unsuccessful, then  
reboot the entire machine. Document the problem, and record all action taken.  
If the problem persists, then contact NT.  
0001/0007  
0001/0020  
Message: [PRU_name] could not free memory. User action is required. [Two  
80 character lines of optional data.]  
Description: The PRU or task was unable to perform because it could not  
free enough memory.  
Action: Courtesy down the PRU, then return it to service. If this action does  
not solve the problem, then reboot the SRU. Document the problem, and  
record all action taken. If the problem persists, then contact NT.  
Message: [PRU_name] was attempting to perform an SDM "Init" and failed.  
Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of  
optional data.]  
Description: When the PRU tries to initialize the Service Data Manager it fails.  
Class error codes are: 1) run error, 2) task error, and 3) IO error.  
Action: This log should never occur. If it does, contact NT immediately.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (020A)  
DNC Logs 43  
0001/0021  
0001/0022  
Message: [PRU_name] was attempting to perform an SDM "Set Atomic  
Commit" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two  
80 character lines of optional data.]  
Description: The PRU tries to set the atomic commit for a Service Data  
Manager operation and fails. Class error codes are: 1) run error, 2) task error,  
and 3) IO error.  
Action: This log should never occur. If it does, contact NT immediately.  
Message: [PRU_name] was attempting to perform an SDM "Add table  
TransID" and failed. table Name = [SDM_table] Access Mode = [read only/read-  
write]. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character  
lines of optional data.]  
Description: When the PRU tries to add a table to the Service Data Manager,  
it fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The  
error may be caused by a full internal array or a duplication in table names.  
Action: Record all information for NT.  
0001/0023  
0001/0024  
0001/0025  
Message: [PRU_name] was attempting to perform an SDM "Set TNUM  
TransID" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two  
80 character lines of optional data.]  
Description: The PRU tries to set TNUM transID for a Service Data Manager  
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error.  
Action: This log should never occur. If it does, contact NT immediately.  
Message: [PRU_name] was attempting to perform an SDM "Get TNUM  
TransID" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two  
80 character lines of optional data.]  
Description: The PRU tries to get a TNUM transID for a Service Data Manager  
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error.  
Action: This log should never occur. If it does, contact NT immediately.  
Message: [PRU_name] was attempting to perform an SDM "Init TransID" and  
failed. table Name = [SDM_table] Access Mode = [read only/read-write]. Error  
Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of  
optional data.]  
Description: The PRU tries to initialize transID for a Service Data Manager  
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error.  
Action: This log should never occur. If it does, contact NT immediately.  
0001/0026  
Message: [PRU_name] was attempting to perform an SDM "Start Transaction"  
and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80  
character lines of optional data.]  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
44 Common TOPS VSN log messages (020A)  
Description: The PRU tries to start a transaction with the Service Data  
Manager and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error. This log indicates that another user has already opened some of the  
required files or tables.  
Action: Record all information for NT.  
0001/0027  
0001/0028  
Message: [PRU_name] was attempting to perform an SDM "End Transaction"  
and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80  
character lines of optional data.]  
Description: The PRU tries to end a transaction with the Service Data  
Manager and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error. The files or tables could not be committed.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Open table" and  
failed. table Name = [SDM_table] Access Mode = [read only/read-write]. Error  
Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of  
optional data.]  
Description: The PRU tries to open a Service Data Manager table and fails.  
Class error codes are: 1) run error, 2) task error, and 3) IO error. The error may  
be caused by a full internal array or when the table does not exist.  
Action: Record all information for NT.  
0001/0029  
0001/002A  
0001/002B  
Message: [PRU_name] was attempting to perform an SDM "Add table" and  
failed. SD table Name = [SDM_table], DD table Name = [data_dictionary_table],  
File Name = [Helix_filename]. Error Type = [Helix_IO_result], Error Class =  
[1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to add a Service Data Manager table and fails.  
Class error codes are: 1) run error, 2) task error, and 3) IO error. The error may  
be caused by a full internal array or when the table has already been added.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Change table"  
and failed. table Name = [SDM_table]. table change Type = [new_attribute/  
new name/new DD name]. Error Type = [Helix_IO_result], Error Class = [1,2,3].  
[Two 80 character lines of optional data.]  
Description: The PRU tries to change a Service Data Manager table and fails.  
Class error codes are: 1) run error, 2) task error, and 3) IO error. This log is  
generated when the table does not exist.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Delete table" and  
failed. table Name = [SDM_table]. Error Type = [Helix_IO_result], Error Class =  
[1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to end a transaction with the Service Data  
Manager and fails. Class error codes are: 1) run error, 2) task error, and 3) IO  
error. This log is generated when the table does not exist.  
Action: Record all information for NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Tops log messages (020A)  
DNC Logs 45  
0001/002C  
0001/002D  
Message: [PRU_name] was attempting to perform an SDM "Read table" and  
failed. table Name = [SDM_table]. Error Type = [Helix_IO_result], Error Class =  
[1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to read a Service Data Manager table and fails.  
Class error codes are: 1) run error, 2) task error, and 3) IO error. This log is  
generated when the table does not exist.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Add Tuple" and  
failed. table Name = [SDM_table]. Tuple ID = [tuple_name]. Error Type =  
[Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to add a tuple to a Service Data Manager table  
and fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The  
log may be generated when the tuple already exists in the table, or when the  
table does not exist.  
Action: Record all information for NT.  
0001/002E  
0001/002F  
0001/0030  
Message: [PRU_name] was attempting to perform an SDM "Change Tuple"  
and failed. table Name = [SDM_table]. Tuple ID = [tuple_name]. Error Type =  
[Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to change a tuple in a Service Data Manager table  
and fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The  
log may be generated when the tuple can not be found, or when the table does  
not exist.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Delete Tuple"  
and failed. table Name = [SDM_table]. Tuple ID = [tuple_name]. Error Type =  
[Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to delete a tuple in a Service Data Manager table  
and fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The  
log may be generated when the tuple can not be found, or when the table does  
not exist.  
Action: Record all information for NT.  
Message: [PRU_name] was attempting to perform an SDM "Read Tuple" and  
failed. table Name = [SDM_table]. Tuple ID = [tuple_name]. Error Type =  
[Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of optional data.]  
Description: The PRU tries to delete a tuple in a Service Data Manager table  
and fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The  
log may be generated when the tuple can not be found, because the table  
does not exits or when the table has been modified since the last transaction.  
Action: Record all information for NT.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46 Common TOPS VSN log messages (020A)  
0001/0031 Message: [PRU_NAME] could not interpret a triple read from the SDM.  
Table name = [table_name]  
Tuple ID = [tuple_name]  
"Diagnostic String1"  
"Diagnostic String2"  
Description: This log indicates an error in interpreting a field within the  
specified tuple.  
Action: Re-edit the tuple and verify that the fields are all of the correct type.  
0001/0032  
Message: [PRU_NAME] was attempting to perform an SDM "notification  
Registration" and failed.  
Table name = <table_name>  
"Diagnostic String1"  
"Diagnostic String2"  
Description: This log indicates the SDM Notification server may be down or  
faulty.  
Action: Ensure that the SDM Notification Server is in a working state. If the  
problem persists, retain all of the information regarding the problem and contact  
your NT representative.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
47  
8. Common TOPS VSN log  
messages - 0020  
0001/0000  
0001/0001  
0001/0002  
Message: [PRU_name] could not insert Control Link PRU in data structure. It  
is full. Maximum number of control links supported = [max_number]  
Description: The maximum number of controls links the system can support  
has been reached. The maintenance notice PRU is still working but will only  
send notices to the first [max_number] control links up.  
Action: No action  
Message: [PRU_name] could not insert a maintenance notice in data  
structure. Structure is full. Maximum number of notices supported =  
[max_number].  
Description: The maximum number of maintenance notices the system can  
support has been reached.  
Action: The user must delete some notices.  
Message: [PRU_name] could not insert a DMS-link tuple in data structure.  
Structure is full. Maximum number of links supported is [max_number].  
Description: The maximum number of DMS-links the system can support  
has been reached.  
Action: The user must delete some links.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
49  
9. Voice interface resource manager  
log messages - 0220  
0000/0000  
Message: Error encountered attempting to load DTMF patterns. The symbol  
[symbol] is referenced in the table [table_name] but not found in the table  
[table_name].  
Description: Applications can not access the VIs because of a reference  
error in an SDM table. This table can not be accessed by the user.  
Action: Contact NT to correct the problem.  
0000/0001  
Message: Error encountered attempting to load DTMF patterns.  
Description: Applications can not access the VIs because of a reference  
error in an SDM table. This table can not be accessed by the user.  
Action: Contact NT to correct the problem.  
0000/0002  
Major  
Message: VIRM has been unable to load DTMF patterns. The specific  
problem encountered is described in another log.  
Description: The Voice Interface Resource Manager could not load an SDM  
table. Either the previous, but usually the log immediately following this one,  
identifies the specific problem.  
Action: The problem identified in the qualifying log must be corrected.  
When corrected, the VIRM must be reload. The alarm clears once this is done.  
0000/0003  
Message: Any outstanding alarms generated by the VIRM have been cleared.  
Description: This log is generated every time the VIRM PRU is brought into  
service. There may not be any outstanding alarms when the VIRM is brought  
into service.  
Action: No action.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
51  
10. Alarm Subsystem - 8722  
0001/0001  
Message: Alarm Interface Unit has RECEIVED an external alarm.  
External ALIU input is: <string>.  
Explanation: The ALIU has sensed remote activation of an alarm condition.  
The string stating the error is one of the following:  
FAN 1 FAILURE  
POWER CONVERTER 1 FAILURE  
POWER CONVERTER 2 FAILURE  
FUSE FAILURE  
FAN 2 FAILURE  
POWER CONVERTER 3 FAILURE  
POWER CONVERTER 4 FAILURE  
USER 1 INPUT  
USER 2 INPUT  
USER 3 INPUT  
Action: The system should be serviced according to the troubleshooting  
procedures in NTP 450-1011-501. System troubleshooting should only be  
performed by qualified service personnel (that is, a system administrator or  
maintenance technician).  
0001/0002  
Message: Alarm Interface Unit has RECOVERED an external alarm.  
External ALIU input is: <string>.  
Explanation: The ALIU has sensed the clearing of the externally generated  
alarm. The string stating the error is one of the following:  
FAN 1  
POWER CONVERTER 1  
POWER CONVERTER 2  
FUSE  
FAN 2  
POWER CONVERTER 3  
POWER CONVERTER 4  
USER 1 INPUT  
USER 2 INPUT  
USER 3 INPUT  
Action: No action required by the user.  
Message: The alarm subsystem has lost communication with the APTIO  
port. Please check the status of the APTIO port <port-name>.  
Explanation: The link between the alarm subsystem and the "alarm box" has  
been disconnected. The alarm box is a separate visual indicator of alarms.  
0005/0001  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
52 Alarm Subsystem (8722)  
Action: The system administrator must check the status of the APTIO port  
according to NTP 450-1011-301. If the fault has not been detected at the  
port, the operation of the LIU must be checked. It must also be determined  
if the cabling from the DNC to the LIU is intact.  
0005/0002  
0020/0000  
Message: The alarm subsystem has recovered communication with the  
APTIO port. APTIO port <string>.  
Explanation: The alarm subsystem was able to reconnect with the APTIO  
port and is now functioning properly. The link between the alarm subsystem  
and the alarm box has been restored and is functioning normally.  
Action: No action required by the user.  
Message: Unable to access disk "LOCAL".  
Explanation: This log indicates that a communication error has occurred to  
the local system disk. Call processing will not be interrupted. Locality calls  
will be handled according to parameter LOC_DEFAULT_PROMPT in the  
user interaction table.  
Action: If the problem persists, retain all of the information regarding the  
problem and contact your NT representative.  
0020/0001  
0020/0002  
Message: I/O Error <I/O-error-number> saving log to disk.  
The new alarm subsystem history file was created successfully.  
Explanation: The alarm subsystem has recovered from the error situation by  
creating a new history file and starting fresh. The original history file was  
renamed from ALARMHIST to ALARMHIST.YY_MM_DD.  
Action: No action required by the user.  
Message: Unrecoverable I/O Error <I/O-error-number> saving log to disk.  
Action may be required by the system administrator.  
Explanation: The alarm subsystem could not recover from the error  
situation by creating a new history file and starting fresh.  
Action: A system administrator with superuser authority must remove the  
current alarm history file :LOCAL:PRU:LOGS:HISTORY:ALARMHIST and  
then reload the alarm subsystem PRU.  
0020/0003  
Message: The alarm subsystem disk task was unable to find its initialization  
file: :LOCAL:PRU:LOGS:AL:ALINIT.TEXT. Default values have been  
supplied.  
Explanation: The alarm system's initialization file is probably missing from  
the system. The alarm subsystem initializes itself using available default  
values.  
Action: A system administrator with superuser authority must check the load  
tape for the presence of the initialization file and replace this file if  
necessary.  
0020/0004  
Message: The Current Alarm Service history file is larger than that specified  
in the initialization file ':LOCAL:PRU:LOGS:AL:ALINIT'. A new alarm  
subsystem history file was created successfully.  
Explanation: The alarm subsystem has created a new history file and is  
starting fresh. The original history file was renamed from ALARMHIST to  
ALARMHIST.YY_MM_DD.  
Action: No action required by the user.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
53  
11. ACPE resource manager log  
messages - 9440  
0000/0000  
Message: [PRU_name] has detected the termination of an ACPE identified  
as [dead_PRU_name] [dead_PRU_number]. [Number_of_calls] will be  
terminated.  
Description: An ACPE PRU has died. All calls the ACPE was processing at  
the time the PRU died, are lost. If the ACPE died because of a fault, an alarm is  
sounded. If the ACPE died because it was courtesied down, then no alarm is  
generated.  
Action: Verify in SAS that the ACPEs go into service.  
0000/0001  
0000/0002  
Message: [PRU_name] has detected the activation of an ACPE identified as  
[act._PRU_name] [act._PRU_number].  
Description: An ACPE PRU has been brought into service.  
Action: No action.  
Message: Invalid call reference returned from the ACPE. Call returned: Tag =  
[sent (ACPE-RM)_id_number], CallID = [returned_id_number], DMSref =  
[DMS_CLLI], DMSID = [DMS_id], Voice Channel = [voice_channel_id].  
Description: The ACPE-RM made a request to the ACPE. When a  
response was made by the ACPE, the identifying parameters did not match  
those sent. The ACPE-RM ignored the response from the ACPE.  
Action: No action.  
0000/0003  
Message: An illegal state transition occurred. Call affected was: Tag = [sent  
(ACPE-RM)_id_number], CallID = [returned_id_number], DMSref =  
[DMS_CLLI], DMSID = [DMS_id], Voice Channel = [voice_channel_id], Current  
State = [current_call_state], Next State = [next_call_state].  
Description: This error should never occur.  
Action: No action.  
0000/000A  
0000/000B  
Message: SET entry invoked - Aborting a call. Call aborted is: CallID =  
[returned_id_number], DMSref = [DMS_CLLI], DMSID = [DMS_id], Voice  
Channel = [voice_channel_id].  
Description: The call has been manually aborted.  
Action: No action.  
Message: SET entry invoked - Making an ACPE inactive. The ACPE made  
inactive was: [PRU_name] [PRU_number]. New load is: [load_id].  
Description: The ACPE PRU has been made inactive manually.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
54 ACPE Resource Manager Log Messages (9440)  
Action: No action.  
0000/000C  
Message: SET entry invoked - Changing the load on an ACPE. The ACPE  
was: [PRU_name] [PRU_number].  
Description: The ACPE load has been set manually. This value is reset by  
the next interaction with the ACPE.  
Action: No action.  
0000/000F  
0000/0010  
0000/0011  
0000/0012  
0000/0013  
0000/0014  
0000/0015  
0000/0027  
Message: SET entry invoked - The ObjectID passed is not supported. Object  
Type was: [object_type]. Object Index was: [object_index].  
Description: The object is not curently supported.  
Action: No action.  
Message: SET entry invoked - Set on "call" failed. Call reference did not  
match an active call.  
Description: The "set" did not operate properly. Invalid data was sent.  
Action: No action.  
Message: SET entry invoked - Set on "de-activating an ACPE" failed. PRU  
number did not match an active ACPE.  
Description: The "set" did not operate properly. Invalid data was sent.  
Action: No action.  
Message: SET entry invoked - Set on "setting load" failed. PRU number did  
not match an active ACPE.  
Description: The "set" did not operate properly. Invalid data was sent.  
Action: No action  
Message: SET entry invoked - Set on "setting load" failed. The load value  
must be between 0 ..100.  
Description: The "set" did not operate properly. Invalid data was sent.  
Action: No action.  
Message: SET entry invoked - Set on "algorithm selection" failed. PRU  
number did not match an active ACPE.  
Description: The "set" did not operate properly. Invalid data was sent.  
Action: No action.  
Message: SET entry invoked making an ACPE ACTIVE. The ACPE made  
active was :[PRU_NAME], <ACPE_location>  
Description: This log indicates that an ACPE has been manually set to active.  
Action: No action required.  
Message: <PRU_name> (Tokenizer) Disk status over threshold. Stopping  
collection.  
Description: Sample data collected is not written to disk because it is full.  
The daily audit cleans the disk of sample data, at which time sample data is  
written to disk again. Call processing continues as usual and no effect to  
service is seen.  
Action: No action.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACPE Resource Manager Log Messages (9440) 55  
0000/0028  
Message: <PRU_name> (Tokenizer) Disk status is now lower than threshold.  
Will start collection.  
Description: Sample data collected is now written to disk. The daily audit  
has made room for new sample data. Call processing continues as usual and  
no effect to service is seen.  
Action: No action.  
0000/002A  
0000/002B  
Message: <PRU_name> Tokenizer logged into server. Collection will start.  
Server name = <server_id>.  
Description: Sample data is collected via server. Call processing continues  
as usual and no effect to service is seen.  
Action: No action.  
Message: <PRU_name> Tokenizer located file server. Collection will start.  
Server name = <server_id>.  
Description: File server has been located. File server is required for the  
collection of sample data. Call processing continues as usual and no effect to  
service is seen.  
Action: No action.  
0001/0004  
0001/0005  
0001/0006  
Message: [PRU_name] could not query the ACPE [queried_PRU_name], for  
its loading. The length of data returned did not match the length requested.  
Description: There has been a data mismatch between the ACPE-RM and  
the ACPE. This mismatch is probably the result of incompatible PRU versions.  
Action: Both the ACPE-RM and the ACPE should be reloaded from tape,  
and then brought back into service. Keep a record of the error for NT.  
Message: [PRU_name] could not query the ACPE [queried_PRU_name], for  
its calls. The length of data returned did not match the length requested.  
Description: There has been a data mismatch between the ACPE-RM and  
the ACPE. This mismatch is probably the result of incompatible PRU versions.  
Action: Both the ACPE-RM and the ACPE should be reloaded from tape,  
and then brought back into service. Keep a record of the error for NT.  
Message: [PRU_name] has filled up it's table for handling ACPEs.  
[PRU_name_2] will not be added. The maximum number of supported ACPEs  
is <number>.  
Description: A maximum number of ACPEs are supported. The maximum  
number has been reached and all others brought into service are ignored.  
Action: No action.  
0001/0007  
0001/0020  
Message: [PRU_name] has filled up it's table for handling calls. The maximum  
number of supported calls is <number>.  
Description: A maximum number of calls are supported. The maximum  
number has been reached and all others presented to the PRU are ignored.  
Action: No action.  
Message: [PRU_name] could not get a heap for the tokenizer task. No token  
could be issued. [Two 80 character lines of optional data.]  
Description: Unable to issue tokens. Call processing continues as usual  
and no effect to service is seen.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56 ACPE Resource Manager Log Messages (9440)  
Action: No action.  
0001/0021  
Message: [PRU_name] Non success return from tokenizer task, from INIT  
entry. No tokens will be issued. [Two 80 character lines of optional data.]  
Description: Unable to issue tokens because of unsuccessful return code  
from tokenizer. Call processing continues as usual and no effect to service is  
seen.  
Action: No action.  
0001/0022  
Message: [PRU_name] Exception entry invoked. All tokens will be turned  
off. [Two 80 character lines of optional data.] Error Class = <class_id>. Error  
Type = <type_id>.  
Description: Unable to issue tokens and all issued tokens are stopped  
because of exceptional entry. Call processing continues as usual and no effect  
to service is seen.  
Action: No action.  
0001/0023  
0001/0024  
0001/0025  
0001/0026  
0001/0029  
Message: [PRU_name] Tokenizer read an invalid server name. table =  
TOKEN CONTROL. Server name = <server_id>.  
Description: Unable to issue tokens because of an invalid server name was  
read. Call processing continues as usual and no effect to service is seen.  
Action: No action.  
Message: [PRU_name] Tokenizer read an invalid entry in a table. table =  
TOKEN SCHEDULE. Key = <key_id>.  
Description: Unable to issue tokens because an invalid table entry was read.  
Call processing continues as usual and no effect to service is seen.  
Action: No action.  
Message: [PRU_name] Tokenizer obtained a zero volume size from the  
server name.  
Description: The tokenizer encountered an invalid volume size. Call  
processing continues as usual and no effect to service is seen.  
Action: No action.  
Message: [PRU_name] Tokenizer encountered an invalid directory name.  
Directory name = <directory_id>.  
Description: The tokenizer encountered an invalid directory name. Call  
processing continues as usual and no effect to service is seen.  
Action: No action.  
Message: [PRU_name] Tokenizer could not log into server. Server name =  
<server_id>.  
Description: The tokenizer had problems logging into the server. Call  
processing continues as usual and no effect to service is seen.  
Action: No action.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
57  
12. Control link log messages - 9441  
0000/0000  
Message: Data Link [link_identifier] to DMS [common_language_location  
_identifier] is in service.  
Description: This log is generated when the X.25 Control Link has been  
reset. At initialization time this log is considered a normal occurrence. At any  
other time it is not. Data may have been lost depending on the activity in  
progress at the time of the reset.  
Action: No action is required. The condition indicates that a link is now  
available. If data was lost, if cannot be recovered.  
0000/0001  
Message: Data Link [link_identifier] to DMS [common _language_location  
_identifier] is out of service. Reason = [reason].  
Description: This log is generated when the X.25 Control Link is no longer  
available for use. Data may have been lost depending on the activity in  
progress at the time of the reset. The reason may be one of the following: 1)  
X.25 PRU managing link is down ( The X.25 PRU is out of service), or 2) Link is  
down (X.25 service associated with the physical link has been reset and is no  
longer available).  
Action: No action is required if within 30 seconds a log is generated  
indicating that the specified data link is now available. If this log does not follow,  
check all physical connections. If all are in good order, the problem is likely  
associated with a DMS failure (i.e.. MPC card). If the reason given is X.25 PRU  
Failure, the PRU must be returned to service. If a return to service does not  
happen automatically, it means the maximum fault count limit has been  
exceeded. This indicates that the processor is in trouble.  
0000/0002  
4
Message: Data Link PRU has bad initialization data.  
Reason = [reason].  
Description: This log is generated when invalid data has been found in  
"Datalink_Config" or "VSN_System" tables for a particular Data Link (DL) PRU.  
The reason given may be one of the following: 1) too many links (more than 4  
links have been configured for each DL PRU), 2) Data Link tables are missing 3)  
no links defined in tables (no links are defined in Datalink_Config table), 4) X.25  
PRU referenced in table does not exist (the X.25 PRU number in Datalink  
Config table does not exist), 5) no call sanity timeout parameter defined in  
VSN_System table, 6) No maximum calls allowed parameter defined in  
VSN_System table, 7) no VSN identifier defined in VSN_System table, 8) two  
different DMS CLLIs defined for one Data Link PRU.  
Action: Modify data entry in Datalink_Config or VSN_System tables, then  
reinitialize the failed DL PRU.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
58 Control Link Log Messages (9441)  
0000/0003  
Message: A Datalink message was discarded. Destination = [DMS_or_VSN].  
Reason = [reason].  
Message Type = [message_type].  
Description: This log is generated when the X.25 Datalink software  
encounters a problem sending a message. The reason is one of the following:  
1) Message type received from application is not supported, 2) Message type  
received on link is not supported, 3) problem relaying message to X.25  
(outgoing message could not be sent to X.25 for transmission), 4) too many  
messages for Datalink PRU to manage (PRU has received more messages than  
it can send out), 5) problem relaying message to VSN application (message  
received by AABS could not be relayed to VSN), 6) attempt to send message to  
a DMS that is not supported, 7) attempt to send message with invalid callID.  
Action: If both data links have failed, then reboot the PRUs involved. If the  
problem is not failed data links, contact NT for support.  
0000/0004  
4
Message: Datalink PRU received a message from an unknown link. Software  
location = [message_received_by].  
Description: This log indicates a serious internal problem. The location  
given may be either 1) xmtHandler (Datalink's transmit handler), or 2) nData  
Reply (Datalink's X.25 data acknowledgement entry).  
Action: Contact NT immediately.  
0000/0005  
Message: Data Link PRU encountered an event while in an incorrect internal  
state.  
Event = @ & 27* current state = @ & 27*  
Description: This log indicates that a Datalink PRU encountered an event  
that should not have happened while in its current internal state. This may  
indicate an internal problem.  
Run Time Parameters (RTP)  
First RTP is a string indicating what the new event is.  
Second RTP is a string indicating what the current state is.  
Action: If the problem persists, retain all of the information regarding the  
problem and contact your NT representative.  
0000/0006  
4
Message: Datalink PRU's outgoing message queue reached a module 10  
length. Number of messages in queue = [num_message].  
Description: The Datalink PRU maintains a queue of messages that are  
outbound, that is destined for the DMS. When this queue grow large, some  
delays may occur in user interaction. This log indicates how large this queue  
has grown when it reaches a size which is a multiple of 10.  
Action: No action required. This message is for informational purposes only.  
0000/0007  
4
Message: An outgoing message was in the Data Link PRU's queue for an  
abnormally long time. Time in milliseconds = [time].  
Description: The Datalink PRU maintains a queue of messages that are  
outbound, that is destined for the DMS. When this queue grow large, some  
delays may occur in user interaction. This log indicates how long a message has  
been in the queue before it was transmitted if the time is greater than 3  
seconds.  
Action: No action required. This message is for informational purposes only.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
59  
13. Application call processing  
engine log messages - 9442  
0000/0000  
Message: <PRU_name>, has just become operational. Call processing  
capacity of this ACPE is now 24 out of 24 calls. All pending minor alarms against  
this ACPE PRU will be cleared. [Two 80 character lines of optional data.]  
Description: This log is generated each time the ACPE is rebooted. If there  
were alarms pending against the PRU they are cleared.  
Action: No action.  
0000/0001  
Message:<PRU_name>, Initialization sequence aborted. Error or  
inconsistency encountered while loading ACPE initialization data. [Two 80  
character lines of optional data.]  
Description: An error or inconsistency was found in ACPE datafill. The  
additional information is provided for NT, not operating company personnel.  
Action: Contact NT immediately.  
0000/0002  
0000/0100  
Message: <PRU_name>, Initialization error occurred; ACPE PRU initialization  
sequence aborted. [Two 80 character lines of optional data.]  
Description: An error occurred while initializing the ACPE PRU. The  
additional information is provided for NT, not operating company personnel.  
Action: Contact NT immediately.  
Message: <PRU_name>, encountered a call error. Automatic recovery will be  
initiated. Other calls being processed by this ACPE should not be affected.  
[Two 80 character lines of optional data.]  
Description: The error has only affected a single subscriber call. The ACPE  
should recover itself. If this log is generated many times in a short period of  
time, the ACPE has encountered a serious error and can not recover  
automatically.  
Action: No action is required if this event occurs periodically. If this log  
occurs often over a short period of time, take the ACPE PRU out of service, and  
then return it to service.  
0000/0102  
0000/0103  
Message: <PRU_name>, has noted a call event. Calls in progress and new  
calls should not be affected. [Two 80 character lines of optional data.]  
Description: The ACPE is simply reporting an anomaly.  
Action: No action.  
Message: <PRU_name>. Automatic recovery of a failed call has been  
initiated. The call will be aborted/rejected as appropriate. [Two 80 character  
lines of optional data.]  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
60 Application Call Processing Engine Log Messages (9442)  
Description: The ACPE is beginning automatic recovery. The failure has  
only affected one subscriber call. If this log is generated many times in a short  
period of time, the ACPE has encountered a serious error and can not recover  
automatically.  
Action: No action is required if this event occurs periodically. If this log  
occurs often over a short period of time, take the ACPE PRU out of service, and  
then return it to service.  
0000/0104  
Message: <PRU_name>, has encountered a serious error. The ACPE has  
encountered a serious error which it cannot recover from. It will continue to  
process calls, but at a diminished capacity. A minor alarm will be generated,  
which can be cleared by rebooting this ACPE PRU. [Two 80 character lines of  
optional data.]  
Minor  
Description: The ACPE has encountered problems that have affected its  
capacity to process calls.  
Action: No immediate action is required since the ACPE is still capable of  
processing calls. When capacity is too low, reboot the PRU.  
0000/0105  
Message: <PRU_name>, has detected a fatal error. This ACPE PRU has  
detected a serious problem which prevents it from continuing to operate. Any  
calls being processed will be aborted. [Two 80 character lines of optional data.]  
Description: The ACPE has encountered a serious problem. All calls being  
processed at the time of the problem have been aborted. The ACPE PRU is  
automatically rebooted by the system.  
Action: No immediate action is required because the PRU is rebooted  
automatically. If the problem persists contact NT with a record each time the  
problem occurred.  
0000/0106  
Message: <PRU_name>, has encountered a serious error.  
Description: The ACPE has detected that the locality database is no longer  
in service. All calls will continue to be processed; locality calls will be handled  
according to the datafill of parameters of the field Locality_Check and  
Loc_Default_Prompt in table User Interaction. [Two 80 character lines of  
optional data]  
Action: No immediate action is required because the ACPE continues to  
process calls, but at a reduced capacity.  
0000/0107  
0000/0108  
Message: <PRU_name>, Event  
Description: The ACPE has detected that the locality database is returning  
to service. The ACPE will process locality calls when the Locality Database is in  
the Working state.  
Action: No action is required.  
Message: <PRU_name>,Locality Prompt Too Long.  
Description: The ACPE could not play the locality prompt for this call  
because it exceeds the maximum length that is currently handled (16,000  
bytes, approximately 7.5 seconds). This call is handled according to the datafill  
of parameter Loc_Default_Prompt in table User Interaction.  
Action: Shorten the prompt by using the Prompt Manager to eliminate the  
pre-prompt silence or the post-prompt silence. If this procedure is not  
adequate, a different prompt should be created.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Call Processing Engine Log Messages (9442) 61  
0003/0001  
Message: ACPE error. Unable to initialize; duplicate datafill detected during  
executor initialization: [duplicate_data_string] reading SDM table:  
[table_name].  
Description: This log is generated if a duplicate string is detected by the  
ACPE when reading an SDM table. This means there is ambiguous reference  
in the datafill. The ACPE can not go into a working state.  
Action: Change the datafill for one of the entries. (The location of the  
duplicate data is given. The first occurrence of the data string is not specified.)  
0003/0002  
Message: ACPE error. Unable to initialize; unresolved reference:  
[offending_reference] in SDM table: [table_name].  
Description: This log is generated when datafill in the specified table  
references a symbol that cannot be found. The ACPE cannot go into a working  
state.  
Action: The unresolved reference must be corrected. (The locations in  
which the search took place are unspecified.)  
0003/0003  
0003/0004  
Message: ACPE error. Unable to initialize SDM table: [table name] is too  
large. Maximum size is [number_of_entries].  
Description: This log is generated when the number of entries in a table  
exceeds the maximum. The existing data structure is unable to hold all the data.  
Action: Reduce the size of the table. The maximum table size is hard coded  
and cannot be changed.  
Message: ACPE detected Voice Interface error. [Error_type_detected].  
Source of error was Voice Interface SRU located at cabinet [number], slot  
[number], channel [number]. VI error code: [decimal], Executor Involved:  
[executor_name].  
Description: This log is generated when the Voice Interface (VI) returns an  
error condition that is not caused by user interaction. The call is usually aborted.  
The [error_type_detected] gives a brief description of the error.  
Action: No action. If the problem persists, it may be necessary to change the  
specified voice channel or the whole SRU.  
0003/0005  
0003/0006  
Message: ACPE error. A parameter error was detected by the executor  
[executor_name]. Debugging Information: [parameter/value].  
Description: This log is generated when an executor detects an error in an  
input parameter.  
Action: Contact NT  
Message: ACPE error. An attempt was made to concatenate two different  
coding methods. The prompts were: [segment_file_1] and [segment_file_2].  
Debugging Information: [parameter/value].  
Description: This log is generated when a MPLPC-coded prompt is  
concatenated with a prompt coded in PCM.  
Action: Record all information and report the problem to NT.  
0003/0008  
Message: ACPE error. An attempt has been made to allocate more  
[procedure_variable_type] procedures than the associated data structure can  
hold. This indicates that there was an error while creating the ACPE. The  
maximum number of provars permitted in the structure is [number].  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
62 Application Call Processing Engine Log Messages (9442)  
Description: This log is generated when to many procedure variables have  
been added to the ACPE data structure. The ACPE will not load.  
Action: Record all information and report the problem to NT.  
0003/0009  
0003/000A  
Message: ACPE error. A software error has been detected. See the debug  
information for details. Debugging Information: [parameter/value].  
Description: This log is generated when there is an error in the code.  
Action: Record all information and report the problem to NT.  
Message: ACPE error. The maximum number of OMs, [number], which may  
be declared in the SDM table [table_name] has been exceeded.  
Description: This log is generated when there are too many entries in a  
specific table.  
Action: Record all information and report the problem to NT.  
0003/000B  
0003/000C  
0003/000D  
Message: ACPE error. An unknown action string [offending_string] has been  
found in the SDM table [table_name]. As a result the ACPE will not load.  
Description: This log is generated when an unknown screening code action  
has been specified in an SDM table. The ACPE will not load.  
Action: Correct the screening code error using the help information in the  
table editor.  
Message: ACPE error. An invalid screening code [offending_code] has  
been found in the SDM table [table_name]. As a result the ACPE will not load.  
Description: This log is generated when an invalid screening code action  
has been specified in an SDM table. The ACPE will not load.  
Action: Correct the screening code error using the help information in the  
table editor.  
Message: ACPE error. The silence prompt for PCM/MPLPC was not loaded  
but was referenced.  
Description: This log is generated when a silence should be played  
between concatenated prompts but has not been loaded. The ACPE will not  
load.  
Action: Record all information and report the problem to NT. The silence  
must be loaded or all references to the silence must be deleted.  
0003/000E  
Message: ACPE error. Unable to allocate VI channel for call. Call was  
rejected. The template set requested was [template_name]. Debugging  
Information: VIRM code: [decimal].  
Description: This log is generated when there are no VI channels available  
to handle the call. Typically this log means that some channels are out of  
service.  
NOTE: This log occurs very often when channels are out of service, therefore  
thresholding has been set at 100 over a period of two minutes. Thresholding  
can be changed to suit the conditions.  
Action: Restore the VI channels that are down. If more than eight channels  
are down, the SRU may be faulty. If the SRU is faulty replace it with the spare. If  
the channels will be down for an extended period, the thresholding can be  
changed or the whole log suppressed.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Call Processing Engine Log Messages (9442) 63  
0003/000F  
Message: ACPE error. Unable to allocate T1 channel for call. Call was  
rejected. The CLLI of the DMS from which the call originated was [DMS_CLLI].  
The voice channel on which the call was received was [channel_id]. Debugging  
Information: T1RM code: [decimal].  
Description: This log is generated by the T1 Resource Manager when it is  
unable to allocate T1 resources for the call. The T1RM return code is given.  
Action: No action is required.  
0003/0010  
0003/0011  
Message: ACPE error. Unable to connect VI channel to voice channel via the  
VNM. Debugging Information: VNM code: [decimal].  
Description: This log is generated by the Voice Network Manager when it is  
unable to connect the T1 to the VI. The VNM return code is given.  
Action: No action is required, but the error should be reported to NT.  
Message: ACPE error. Unable to release VI speech slave in cabinet  
[cabinet_number], slot [slot_number] and channel [channel_id]. Debugging  
Information: VI code: [decimal].  
Description: This log is generated by the VI. It is automatically reported to  
the VI Resource Manager. It may indicate problems with the VI channel.  
Action: No action is required.  
0003/0012  
Message: ACPE error. Error encountered while attempting to release the  
voice bus slots being used by both the VI channel at cabinet [cabinet_number],  
slot [slot_number] and channel [channel_id] and a T1 channel. Debugging  
Information: VNM error code: [decimal].  
Description: This log is generated by the Voice Network Manager (VNM)  
when it determines that slots have not been allocated for the T1 and VI. This  
assessment by the VNM may not be accurate. The log indicates that the  
release of the voice bus slots failed.  
Action: No action is required.  
0003/0013  
Message: ACPE error. Error encountered while attempting to release a T1  
channel. Debugging Information: T1RM error code: [decimal].  
Description: This log is generated when unexpected code is received by  
the T1 Resource Manager during a release attempt.  
Action: No action is required.  
0003/0014  
Status  
Message: ACPE error. Error encountered while attempting to release THE VI  
channel at cabinet [cabinet_number], slot [slot_number], channel [channel_id].  
VIRM error code: [decimal].  
Description: This log is generated when unexpected code is received by  
the AudToMem routine. This error may indicate a memory problem.  
Action: No action is required.  
0003/0015  
Status  
Message: ACPE error. Unable to load prompts from audio files. The error  
was not an I/O error. Error code from routine AudToMem: [decimal].  
Description: This log is generated when unexpected code is received by  
the VI Resource Manager during a release attempt.  
Action: Contact NT immediately.  
0003/0016  
Message: no locality processing available for current call  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
64 Application Call Processing Engine Log Messages (9442)  
Description: The ACPE could not determine the locality treatment for the  
current call because the Locality Database is either a new set of locality prompts,  
or a new set of locality prompts is being saved. This call will be handled  
according to the datafill of parameters Locality_Check and Loc_Default_Prompt  
in table User Interaction.  
Action: No immediate action is required because the ACPE continues to  
process calls,(at a diminished capacity).  
0003/0017  
Message: no locality call processing for current call.  
Description: The ACPE could not determine the locality treatment for the  
current call because the Locality Database is not in the Working state. This call  
will be handled according to the datafill of parameters Locality_Check and  
Loc_Default_Prompt in table User Interaction.  
Action: No action is required because the ACPE continues to process  
calls,(at a diminished capacity).  
0003/001A  
0003/0018  
0003/0200  
Message: [PRU_NAME], error. An invalid name plus locality mode, <invalid  
mode>, has been found in table "LOC_SCREEN_CODES". As a result ACPEs  
will not load.  
Description: This log indicates that the valid values for the name plus locality  
mode field are given in the help information in the table editor.  
Action: The table must be corrected before the ACPEs will load.  
Message: ACPE failed to communicate with the Locality Database.  
Description: This call will be handled according to datafill of the parameters  
Locality_Check and Loc_Default_Prompt in table User Interaction. Debugging  
information is provided.  
Action: No action is required because the ACPE continues to process  
calls,(at a diminished capacity).  
Message: State table log  
Description: This is a log that is generated by the state table for application  
TABS. Two lines of state data are provided.  
Action: Action as indicated in the message.  
0003/0201  
Status  
Message: Log generated by state table for application <TABS>. [Call  
abnormally terminated. See trace back for detail.]  
Current state : <state code>  
Called from : <state code>  
via input: <event #>  
via input: <event #>  
Description: This log is generated by the state table when it encounters an  
error during an event sequence.  
Action: Contact NT immediately. Record the state and event codes listed in  
the log and report them to the NT representative.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
65  
14. T1 resource manager log  
messages - 9443  
0000/0000  
Message: [PRU_name] reports internal software error. [Two 80 character  
lines of optional data.]  
Description: The identified PRU is reporting a fatal internal error. The  
reason for the error may one of many (too many to list) but is clearly identified in  
the body of the message.  
Action: Document the error and message precisely, and then contact NT.  
The PRU must be reloaded.  
0000/0001  
Message: [PRU_name] reports administration error. Error = [string]. [Two 80  
character lines of optional data].  
Description: The identified PRU is reporting an administration error. The  
reason for the error is one of the following: 1) Operation successful, 2) Bad  
parameter used, 3) Object versions do not match, 4) Object already exists, 5)  
Object not marked, 6) Object marked by another session, 7) Object marked by  
user profile editor, 8) File contains maximum number of objects, 9) Failed to  
apply an update session, 10) Object name not found, 11-14) Obsolete, 15)  
Administration is busy notifying registered tasks, 16) Administration cannot get  
sufficient memory space.  
Action: Make sure that T1 SRU configuration data is initialized.  
Configuration data is accessed from Digital Trunk Link under SAS configuration.  
(When attempting to save configuration data from T1 Maintenance the Digital  
Trunk Link configuration agent must not be active.)  
0000/0002  
Message: [PRU_name] reports software error for T1 SRU in Cabinet  
[ID_number], Slot [Id_number]. [Two 80 character lines of optional data.]  
Description: The identified PRU is reporting a software error in the T1 SRU.  
The reason for the error is one of the following: 1) Failed to locate configuration  
data for T1 SRU, 2) Failed to locate trunk mapping data for T1 SRU, 3) Fatal error  
detected in the T1 audit task. Task exiting, 4) Fatal error in call processing task.  
Task exiting, 5) Call Processing task for T1 SRU has exited. Task restarting, 6)  
Call processing task for T1 SRU has exited. Task cannot be restarted, 7) Audit  
task for T1 SRU has exited. Task restarting, 8) Audit task for T1 SRU has exited.  
Task cannot be restarted, 9) Failure in trunk status query to T1 SRU, 10) Failure  
in trunk timeslot query to T1 SRU.  
Action: Make sure that T1 configuration data has been initialized. Record all  
information and report it to NT,  
0000/0003  
Message: [PRU_name] reports a T1 maintenance error. [Two eighty  
character lines of system generated information.]  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
66 T1 Resource Manager Log Messages (9443)  
Description: A T1 Maintenance error has been reported.  
Action: Exit, then re-access T1 Maintenance.  
0001/0000  
Message: T1 Link Error for T1 SRU in Cabinet [cabinet_id], Slot [slot_id].  
Condition = [string]. Error Level = [string].  
Description: There is a link error for the T1 SRU at the specified location.  
The reason (condition) for the error is one of the following: 1) Bipolar violation,  
2) Frame slip, 3) Frame loss, 4) Frequency converter unlock, 5) VBus collision,  
6) Line fail, 7) Transmit clock fail, 8) 5ms clock, 9) Peripheral loopback, 10)  
Yellow alarm, 11) Red alarm, 12) A/B buffer overrun.  
The error level is one of the following: 1) Error Cleared, 2) Maintenance Limit  
Attained, 3) Out-of-service limit attained. If the maintenance level is reached,  
the link is still operational. If the out-of-service limit is reached, the T1 link is  
taken out of service.  
Action: Adjust thresholds using digitial trunk link configuration service.  
Make sure that the synchronization manager is operational, and that the T1 link  
is connected properly.  
0001/0001  
Message: T1 Link Event for T1 SRU in Cabinet [cabinet_id], Slot [slot_id].  
Event = [string].  
Description: There is a link event for the T1 SRU at the specified location.  
The event is either of the following: 1) Channels reconnected for T1 link, or 2)  
Channels disconnected for T1 link. When the channels have been  
disconnected all voice channels have been taken out of service. When the  
channels have been reconnected, the number of voice channels specified by  
the maintenance limit are available for use.  
Action: Refer to previous log for direction.  
0002/0000  
Message: Voice Link Event for T1 SRU. Event = Link placed in Standby  
BusiedOut\Standby Inservice\\state.  
Global Event  
Description: One of the T1 links has experienced a change in state. If a link  
is placed “StandBy BusiedOut” or “Standby InService”, the state change is  
normal and has been made either by program control or as requested through  
T1 Maintenance.  
Action: First RTP is an integer (decimal) indicating the cabinet number of the  
T1. Next RTP is an integer (decimal) indicating the slot number of the T1. Next  
number is an integer (selector) specifying the event.  
0002/0001  
Message: Voice Trunk Event for T1 SRU in Cabinet [cabinet_id], Slot  
[slot_id]. Channel = [channel#_id]. Event = [string]. DMS CLLI = [DMS_id],  
Trunk ID = [trunk_id].  
Description: One of the following voice trunk events occurred for the T1  
SRU at the specified location: 1) Trunk placed in remote answer state, 2) Trunk  
placed in remote seized state, 3) Trunk placed in seize failure state, 4) Trunk  
placed in trunk failure state, 5) Channel allocation failure. Trunk not found in T1  
configuration, 6) Channel allocation failure. Trunk not available (not inservice),  
7) Call aborted on trunk due to T1 failure or T1 maintenance action,  
Action: If trunk state is remote answer or remote seized, clear condition by  
making the far-end go on-hook. If trunk state is seize failure or trunk failure,  
clear error through T1 maintenance. If trunk state indicates an allocation  
problem, make sure that the DMS CLLI and TrunkID are correctly datafilled  
under the Digital Trunk Link configuration service.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
T1 Resource Manager Log Messages (9443) 67  
0003/0000  
Message: [PRU_name] has cleared any outstanding T1 Voice Link Alarms.  
Description: This log is generated each time the PRU is rebooted. If there  
were alarms pending against the PRU they are cleared.  
Action: No action.  
0003/0001  
Major  
Message: Voice Link Alarm Event for T1 SRU. Event = Major alarm set for  
failed Standby InService link.  
Description: A Major Alarm has been set for failed (SysBusy) T1 link.  
Action: Clear the alarm by causing the link to leave the SysBusy state - either  
by clearing the error condition, rebooting the T1 SRU, reconfiguring the link to  
Offline, or by removing the SRU from the System Map under SAS -  
CONFIGURATION. User action is required.  
First RTP is an integer (decimal) indicating the cabinet number of the T1. Next  
RTP is an integer (decimal) indicating the slot number of the T1. Next number is  
an integer (selector) specifying the event.  
0003/0002  
Message: Voice Link Alarm Event for T1 SRU. Event = Major Alarm Cleared  
for Standby InService link..  
Description: A Major Alarm has been cleared for a T1 link.  
Action: No action is required.  
First RTP is an integer (decimal) indicating the cabinet number of the T1. Next  
RTP is an integer (decimal) indicating the slot number of the T1. Next number is  
an integer (selector) specifying the event.  
0003/0003  
Minor  
Message: Voice Link Alarm Event for T1 SRU. Event = Minor Alarm set for  
Standby BusiedOut link.  
Description: A Minor Alarm has been set for a failed (SysBusy) T1 link.  
Action: Clear the alarm by causing the link to leave the SysBusy state, either  
by clearing the error condition, rebooting the T1 SRU, reconfiguring the link to  
Offline, or by removing the SRU from the System Map under SAS -  
CONFIGURATION. User action is required.  
0003/0004  
Message: Voice Link Alarm Event for T1 SRU in Cabinet. Event = Minor  
Alarm Cleared for Standby BusiedOut link..  
Description: A Minor Alarm has been cleared for a T1 link.  
Action: No action is required.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
69  
15. Locality database log messages -  
944E  
0000/0000  
Message: The Locality Database has just become operational. Locality  
queries can now be processed. Any pending minor alarms against the Locality  
Database have been cleared.  
Description: This is an information message only.  
Action: None.  
0000/0001  
Message: The LDB has detected a serious problem which prevents it from  
initializing.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: A serious error was encountered by the LDB PRU during  
initialization. The LDB PRU will be automatically rebooted by the system. The  
first diagnostic string describes the nature of the problem, and the second  
diagnostic string gives more information on the problem.  
Action: No action is required unless the condition persists.  
0000/0002  
Message: The LDB has detected a serious problem in initialization in either a  
query handler or the MMI which it cannot recover from. Initialization will  
continue. A minor alarm will be generated, which can be cleared by rebooting  
the LDB PRU or from the Alarm Query MMI.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: The first diagnostic string describes the nature of the problem.  
This string will indicate whether the log concerns a query handler or the MMI. If  
it concerns a query handler, it will show the current number of query handlers.  
The second diagnostic string gives more information about the problem.  
Action: No explicit action is required immediately, as the LDB can continue  
with initialization, but with diminished capacity, as indicated in the log message.  
If the query processing capacity is too low, or if the MMI processing has failed,  
the LDB PRU should be rebooted.  
0000/0003  
Message: The Locality DataBase has detected a problem in initialization of  
Custom Branding information. Initialization will continue.  
"Diagnostic String 1"  
"Diagnostic String 2"  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
70 Locality Database Log Messages (944E)  
Description: The diagnostic strings, which are filled by the LDB PRU,  
describe the nature of the problem. The problem reported may be with the  
custom branding information found in the Custom Brands and Carrier Brands  
SDM tables, or in the Locality Database brand index fields. These problems may  
be the result ofi references to non-existent branding segment prompts in the  
Locality Database, references to non-existent brand indexes, and lack of data  
store memory.  
Action: No explicit action is required immediately, as the LDB can continue  
with initialization, as the Locality Database can continue with initialization.  
Correct the problem and reboot the Locality Database to restore Custom  
Branding service.  
0000/0102  
Message: The LDB has encountered a serious error which it cannot recover  
from in either a query handler or the MMI. It will continue to process LDB  
queries, but at a diminished capacity. A minor alarm will be generated, which  
can be cleared by rebooting the LDB PRU.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: The first diagnostic string describes the nature of the problem.  
This string will indicate whether the log concerns a query handler or the MMI. If it  
concerns a query handler, it will show the current number of query handlers.  
The second string contains more information on the problem.  
Action: No explicit action is required immediately, as the LDB can continue to  
process queries, but with diminished capacity, as indicated in the log message.  
If the query processing capacity is too low, or if the MMI processing has failed,  
the LDB PRU should be rebooted.  
0000/0103  
Message: The LDB has detected a serious problem which prevents it from  
continuing to operate. Any queries being processed will be aborted. All MMI  
operations will be aborted.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: The first diagnostic string describes the nature of the problem,  
the second string gives additional information on the problem.  
Action: A serious error was encountered by the LDB PRU. The LDB PRU will  
be automatically rebooted by the system, so that no action is required, unless  
the condition persists.  
0000/0104  
Message: The LDB has detected an internal software error.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: A serious internal software error was encountered by the LDB.  
If the error is a fatal error and the LDB is unable to continue processing, all  
queries being processed by the LDB PRU will be aborted. All MMI operations  
will be aborted. The first diagnostic string describes the nature of the problem,  
the second string gives additional information on the problem.  
Action: All information on this error should be recorded and reported to NT  
service personnel. The LDB PRU will be automatically rebooted by the system,  
so that no further action is required, unless the condition persists.  
0000/0105  
Message: The LDB has received an error from a system operation.  
"Diagnostic String 1"  
"Diagnostic String 2"  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Locality Database Log Messages (944E) 71  
Description: A serious error was received from a system operation. If the  
error is a fatal error and the LDB is unable to continue processing, all queries  
being processed by the LDB PRU will be aborted. All MMI operations will be  
aborted. The first diagnostic string describes the nature of the problem, the  
second string gives additional information on the problem.  
Action: All information on this error should be recorded and reported to NT  
service personnel. The LDB PRU will be automatically rebooted by the system,  
so that no further action is required, unless the condition persists.  
0000/0106  
Message: The LDB has encountered an error trying to transfer a prompt  
requested by the ACPE to the ACPE executor data space.  
"Diagnostic String 1"  
"Diagnostic String 2"  
Description: The LDB has either received an error from an ACPE executor  
during a prompt transfer, or was unable to start the transfer with the ACPE  
executor, or has no transfer tasks available to allocate to the ACPE. The first  
diagnostic string describes the nature of the problem, the second string gives  
additional information on the problem.  
Action: No action is required unless the condition persists, in which case  
the LDB PRU should be rebooted.  
Message: An error occurred which caused the print task to fail. The Locality  
Database will not be printed. Call processing will not be affected.  
"Diagnostic String 1"  
0000/0201  
"Diagnostic String 2".  
Description: This log indicates that if successive attempts to print the  
Locality Database fail, the Locality Database PRU is to be rebooted.  
Action: If the problem persists, retain all of the information regarding the  
problem and contact your NT representative.  
0000/VQ003  
Message: The user has chosen to install a prompt set that is missing a  
language version of an announcement(s) that existed in the loaded set. Calls  
requested in the missing language version will be handled according to the  
parameter LOC_LANG_UNAVAIL.  
Description: Informational message only.  
Action: No action is required.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
73  
16. ACPE Maintenance Position log  
messages - 9445  
9945/0004  
Message: @1 Initialization sequence aborted. Error or inconsistency  
encountered while loading the ACPE Maintenance Position initialization data.  
xxxxx  
xxxxx  
Description: @1 is the reporting PRU, namely the ACPE Maintenance  
Position.  
xxxxx are two strings that describe the error that was encountered.  
Action: An error has occurred during the ACPE Maintenance Position  
initialization. The problem may be resolved by rebooting the ACPS Maintenance  
Position PRU. This initialization error does not affect call processing. Please  
save this information and contact your NT representative.  
Message: @1 aborted.  
0445/0005  
A serious software error has occurred that caused the ACPE Maintenance  
Position MMI to terminate.  
xxxxx  
xxxxx  
Description: @1 is the reporting PRU, namely the ACPE Maintenance  
Position.  
xxxxx are two strings that describe the error that was encountered.  
Action: This software error does not affect call processing. Please save this  
information and contact your NT representative.  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
75  
17. Prompt manager log messages -  
9451  
0100/0101  
Message: User logged in  
<user name>  
Description: This message is informative only, confirming that the user with  
the <user name> has logged in.  
Action: None.  
0100/0102  
Message: User logged out  
<user name>  
Description: This message is informative only, confirming that the user with  
the <user name> has logged out.  
Action: None.  
0100/0103  
0100/0104  
0100/0105  
Message: Archive Successful  
Description: This message indicates that an archive function has been  
completed successfully.  
Action: None.  
Message: Restore Successful  
Description: This message indicates that a database was successfully  
restored from magnetic tape.  
Action: None  
Message: Install successful  
<set issue>  
Description: This message indicates that a database was successfully  
installed in the TOPS VSM from disk.  
Action: None.  
0100/0106  
Message: Librarian rebuilding  
Description: This is a progress message indicating that the library is in the  
process of being built, and that queries to the database are not possible.  
Action: None.  
0100/0107  
0100/0108  
0100/0109  
Message: Librarian starting  
Message: Librarian running  
Message: Librarian shutdown  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
76 Prompt Manager Log Messages (9451)  
0200/0201  
Message: Forced Exit  
<procedure name>  
<reason for exit>  
Message: Archive Failure  
<reason for failure>  
Message: Restore Failure  
<reason for failure>  
Message: Bad system command  
<procedure name>  
<command>  
0200/0202  
0200/0203  
0200/0204  
0200/0205  
0300/0301  
Message: Install unsuccessful  
Message: Cannot open file  
<detail>  
0300/0302  
0300/0303  
0300/0304  
Message: Cannot create file  
<detail>  
Message: Read failure  
<detail>  
Message: Write failure  
<detail>  
0400/0401  
0400/0402  
Message: No VI channel  
Message: VI error  
<detail>  
0500/0501  
0500/0502  
Message: Lib daemon error  
Timeout  
Message: Lib daemon error  
Library Corrupt  
Restore from backup  
Description:  
0500/0503  
Message: Lib daemon error  
Librarian Dead  
Reboot DVIX  
<detail>  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
77  
18. Suppressed and Thresholded  
Logs  
This section lists the system logs which have been suppressed or thresholded.  
The format for suppressed logs is <Config Number> <Report Number/Error  
Number>. The format for thresholded logs is <Config Number> <Report  
Number/Error Number> <Maximum Threshold> <Duration>  
Suppressed Logs  
0000 00010002  
KERNEL INNER CI  
0002 41010001  
0002 41010011  
0002 41020037  
0002 41050003  
0002 4106003B  
VTP: ERROR 1  
VTP: PHYSICAL DEST IS NON-EXISTENT.  
OAR, Rendezvous error  
SAS, BAD FIELD NUMBER.  
Tape Server, mode conflict  
0003 0001FFFF  
0003 0002FFFF  
0003 0003FFFF  
0003 0004FFFF  
0003 0005FFFF  
0003 0006FFFF  
0003 0007FFFF  
0003 0008FFFF  
0003 0009FFFF  
0003 000AFFFF  
0003 000BFFFF  
0003 000DFFFF  
0003 000EFFFF  
0003 000FFFFF  
PRU operational  
PRU non-operational  
PRU operational  
PRU operation  
PRU appears OK!  
system initialization complete  
enabled  
RM registration  
RM de-registration  
Reload if crashes  
System time set thru SAS  
taken out of service  
X.25, LIU PORT OFFLINE  
PRU initializing  
0004 00020005  
OAR BAD COMMAND  
006D 0000000D  
006D 0000001C  
006D 0000002D  
006D 00000032  
006D 00000035  
OM file audit.  
OMCA: I/F ERROR.  
Number of initiated OMR processors  
Invalid group in OMC file  
No valid OM group  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
78 3. Suppressed and Thresholded Logs  
006D 00000038  
006D 00000039  
006D 0000003A  
File audit status  
OMCA: LOCATE ERROR  
OMCA: LOCATE ERROR (REPORTER)  
0220 00000003  
8004 00020007  
VIRM CLEARING ANY ALARMS  
COULD NOT SEND NOTIFICATION  
800C 00010002  
800C 00010003  
800C 00020005  
800C 0002000C  
OAR, change state  
OAR, registration  
OAR, unable to start activity  
OAR, bad response  
800D 00020005  
800D 00020008  
INIT REQUEST FOR M4020  
Bus control error return code 0001  
8021 00010001  
Long audit response  
8022 0002010B  
8022 00020117  
8022 00010207  
8022 00020113  
SAM help hard key  
SAM  
Alpha operational  
SAM, no response  
8026 0002003A  
8028 00020002  
VNM: SD_DROPS_SLOTS  
HAG, ADMIN READ ERROR ON SN  
RECORD.  
8029 0002002C  
SAS, SFH RETURN CODE  
802E 00020000  
802E 00020001  
SSM T1 Link Switch  
SSM T1 Link Switch  
8220 00010300  
8220 00010301  
8220 00010400  
8220 00020500  
XCM X.25 Link is up  
X.25, XCM: LINK IS DOWN  
X.25, MLP PORT IS DOWN  
NCT: CLIENT REQUEST IGNORED  
852E 00100002  
852E 00100005  
852E 00100006  
Job manager, Job complete successfully  
Job manager, start job  
Job manager, job started  
8602 00010008  
TNAP registration  
8700 00010001  
8700 00010002  
8700 00010003  
8700 00010004  
8700 00010005  
8700 0001000C  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Suppressed and Thresholded Logs 79  
700 00020001  
8700 00020002  
8700 00020003  
8700 00020004  
8700 00020005  
8700 00020006  
8700 00020007  
8700 00020008  
8700 00020009  
8700 00020010  
8700 00020011  
8700 00024104  
8700 00030001  
8700 00030002  
8700 00030005  
8700 00030007  
8700 00040001  
8700 00040003  
8700 00040004  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
Campus resource manager  
8720 00010001  
8720 00030006  
8720 00500002  
UNKNOWN LOG REPORT  
CLEANING UP OF ALARMS  
Logger cache has been modified  
8723 00010001  
8800 00010001  
9440 00000001  
9442 0003000F  
9443 00030000  
QMAN printer ok  
Server file audit completed.  
ACPE-RM detected ACPE  
Unable to allocate T1 channel  
CLEARING ANY ALARMS  
Thresholding Logs  
0004 00020002 100 2  
TIMEOUT XMITTING ERRORS  
Task error on File audit  
File I/O errors  
006D 00000005 255 2  
006D 0000000D 255 2  
006D 0000000E 100 30  
006D 00000037 255 2  
OMR locate Job MGR  
Report End time exceeded  
TRBUFFER TASK RESULT  
OAR unable to start job  
VNM release error due to nil taskid  
Job could not be started  
Unable to communicate with Job Mgr  
CONTROL LINK TIME IN Q  
CONTROL LINK MODULUS  
VNM connect error  
Unable to release speech slave  
VNM release error  
0201 00020015 8  
1
800C 00020004 255 2  
8026 00020031 48 5  
852E 00200002 255 2  
8531 00200004 255 2  
9441 00000007 24 1  
9441 00000006 8  
1
9442 00030010 48 2  
9442 00030011 48 2  
9442 00030012 48 2  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
80 3. Suppressed and Thresholded Logs  
9442 00030013 48 2  
9442 00030014 48 2  
C302 00020018 100 2  
C302 00020010 100 2  
C302 00020017 100 2  
C302 0002000F 100 2  
T1 release error  
VI release error  
VTP return code error  
Link Error  
Port Error  
No response from peer  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
81  
19. DMS notices  
Some events which occur in the TOPS VSN must be reported to the DMS switch.  
The report takes the form of a notification message. The list which follows  
identifies the log/alarm messages sent to the DMS. table VSNALARM on the  
DMS, which is datafilled by the operating company, adds severity and textual  
information to the notification message before it is output on the DMS side. The  
event ID given here corresponds directly to the alarm code in table  
VSNALARM.  
Sub-  
system  
Report & Error  
Number  
Event  
Event ID  
Severity Alarm  
8720  
8720  
8720  
8720  
8720  
8720  
8722  
8722  
8722  
8722  
8722  
8722  
9443  
9443  
9443  
9443  
9442  
9442  
0003  
0003  
0003  
0003  
0002  
0002  
0001  
0001  
0002  
0002  
0003  
0003  
0003  
0003  
0003  
0003  
0000  
0000  
0002 Faulty PRU  
1
1
2
2
3
3
4
4
4
4
4
4
5
5
6
6
7
7
minor  
minor  
critical  
major  
major  
minor  
major  
minor  
minor  
Yes  
No  
0004 PRU Recovered  
0001 Faulty SRU Device  
0003 SRU Device Recovered  
0001 Disk Full  
Yes  
No  
Yes  
No  
0004 Disk Space Reclaimed  
0001 External Alarm  
Yes  
No  
0002 External Alarm Recovered  
0001 External. Alarm  
Yes  
No  
0002 External Alarm Recovered  
0001 External Alarm  
Yes  
No  
0002 External Alarm Recovered  
0001 Inserv T1 Failed  
Yes  
No  
0002 Inserv T1 Recovered  
0003 Busied T1 Failed  
0004 Busied T1 Recovered  
0104 ACPE Capacity Lost  
0000 ACPE Recovered  
Yes  
No  
Yes  
No  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
83  
20. Abbreviations  
A list of abbreviations used in this Publication follows:  
ACPE  
CLLI  
DD  
Application call processing engine  
Common language location indicator  
Data dictionary  
DMS  
DNC  
DTMF  
IEEE  
IO  
Digital multiplex system  
Dynamic network control  
Dual tone multifrequency  
Institute of Electrical and Electronic Engineers  
Input output  
LDB  
MMI  
NT  
Locality database  
Man machine interface  
Northern Telecom  
OM  
Operational measurement  
Pulse code modulation  
Program resource unit  
Resource manager  
PCM  
PRU  
RM  
SAS  
SDM  
SRU  
TOPS  
VI  
System administration service  
Service data manager  
Shared resource unit  
Traffic operator position system  
Voice interface  
VIRM  
VNM  
VSN  
VTP  
VI resource manager  
Voice network manager  
Voice service node  
Virtual transport protocol  
TOPS VSN Log and alarm messages  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network operations systems  
TOPS  
Voice service node  
Log and alarm messages  
Copyright © 1995 Northern Telecom  
All rights reserved.  
TOPS and DMS are trademarks of Northern Telecom.  
NTP 450-1301-511  
Release: VSN04  
Version: 03.01  
Standard  
August 1995  
Printed in the United States of America  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MSB Technology TV Converter Box Rev 1 10 2012 User Manual
NETGEAR Computer Drive Business Edition User Manual
Onkyo Stereo System HT RC260 User Manual
Optimus Microcassette Recorder MICRO 37 User Manual
Orion Car Audio Speaker HCCA 104 User Manual
Panasonic Switch 15000 User Manual
ParaBody Home Gym PBF460 User Manual
Parasound Stereo Amplifier HCA 1200 User Manual
Parkside Sander XQ2 SE User Manual
Partner Tech Tablet EM 200 WIN7;EM200XP User Manual