Nortel Networks Network Router 600r User Manual

Nortel CallPilot  
600r Server Hardware  
Installation  
NN44200-307  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
RADISYS is a trademark of Radisys Corporation.  
SLR4, SLR5, and TANDBERG are trademarks of Tandberg Data ASA.  
SYBASE is a trademark of Sybase, Inc.  
TEAC is a trademark of TEAC Corporation  
US ROBOTICS, the US ROBOTICS logo, and SPORTSTER are trademarks of US Robotics.  
WINZIP is a trademark of Nico Mark Computing, Inc.  
XEON is a trademark of Intel, Inc.  
All other trademarks and registered trademarks are the property of their respective owners.  
Information for Japan  
Japan Denan statement  
The following applies to server models 703t, 1002rp, 1005r and 600r:  
Japan VCCI statement  
The following applies to server models 703t, 201i, 1002rp, 1005r and 600r:  
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information  
Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may occur, in  
which case, the user may be required to take corrective action.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Publication History  
May 2008  
CallPilot 5.0, Standard 01.03 of the CallPilot 600r Server Hardware  
Installation guide is issued for GA.  
May 2007  
CallPilot 5.0, Standard 01.02 of the CallPilot 600r Server Hardware  
Installation guide is issued for GA.  
March 2007  
CallPilot 5.0, Standard 01.01 of the CallPilot 600r Server Hardware  
Installation guide is issued for GA.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Publication History  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Contents  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Chapter 1  
How to get help  
This section explains how to get help for Nortel products and services.  
Getting help from the Nortel Web site  
The best way to get technical support for Nortel products is from the Nortel  
Technical Support Web site:  
This site provides quick access to software, documentation, bulletins, and  
tools to address issues with Nortel products. More specifically, the site  
enables you to:  
download software, documentation, and product bulletins  
search the Technical Support Web site and the Nortel Knowledge Base  
for answers to technical issues  
sign up for automatic notification of new software and documentation  
for Nortel equipment  
open and manage technical support cases  
Getting help over the phone from a Nortel Solutions Center  
If you do not find the information you require on the Nortel Technical Support  
Web site, and have a Nortel support contract, you can also get help over the  
phone from a Nortel Solutions Center.  
In North America, call 1-800-4NORTEL (1-800-466-7835).  
Outside North America, go to the following Web site to obtain the phone  
number for your region:  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10 Chapter 1 How to get help  
Getting help from a specialist by using an Express Routing Code  
To access some Nortel Technical Solutions Centers, you can use an Express  
Routing Code (ERC) to quickly route your call to a specialist in your Nortel  
product or service. To locate the ERC for your product or service, go to:  
Getting help through a Nortel distributor or reseller  
If you purchased a service contract for your Nortel product from a distributor  
or authorized reseller, contact the technical support staff for that distributor  
or reseller.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Chapter 2  
600r server description  
In this chapter  
Conventions for Warnings  
You can encounter the following types of warnings in this guide. Do not  
ignore them.  
DANGER  
Risk of electric shock  
Warns you of an immediate electrical hazard, which, if not avoided,  
results in shock, serious injury, or death.  
WARNING  
Warns you of a situation in which you can be injured if instructions  
are not followed exactly as stated.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
12 Chapter 2 600r server description  
CAUTION  
Alerts you to situations where data can be lost or damaged,  
equipment can be damaged, actions can result in service  
interruption, and productive time can be lost.  
ATTENTION  
Provides information that is essential to the completion of a task.  
Server features  
This section provides a general overview of the 600r server.  
The 600r CallPilot server is a long-life industrial computer server in a  
standard rack-mount 1U form factor. The 600r utilizes current Intel P4  
hyper-threading technology and proven, reliable SCSI hard-drive technology.  
Before you install your 600r server, Nortel recommends that you read this  
guide completely through. Ensure that CallPilot has the latest antivirus  
software. Do not install third-party antivirus software unless approved by  
Nortel. For information about the antivirus software packages that are  
approved by Nortel for CallPilot, see Product Bulletin P-2007-0101-Global  
: CallPilot Support for Anti-Virus Applications. Also, ensure your CallPilot  
application resides behind your network firewall.  
If you have any questions about installing your 600r, contact a Nortel  
representative.  
Ensure a single-point ground reference is available for all the power outlets  
serving the CallPilot server and its peripherals. Before the CallPilot server  
installation, a qualified electrician must implement the single-point ground  
reference requirement between the power outlets of the CallPilot server  
and the power outlets of the switch.  
Server dimensions  
Height  
1.75 inches (44.4 mm)  
17.5 inches (444.3 mm)  
20 inches (507.8 mm)  
Width  
Depth (distance from front to back)  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Server features 13  
front: 2 inches (50.8 mm)  
Clearance  
rear: 3.6 inches (92 mm)  
side: 1 inch (25 mm)  
Weight of fully loaded system with:  
approximately 10 kg (23 lbs)  
SCSI hard drive  
MPB96 board  
DVD/CD/CDRW drive  
Environmental specifications  
Environmental condition  
Specification  
Operating temperature  
+5 C to +35 C (41 F to 95 F)  
Maximum rate of change must not  
exceed 10 C (50 F) per hour.  
Non-operating (storage) temperature  
-40 C to +70 C (-40 F to +158 F)  
95% @ 23-40 C  
<6000 ft. (1829 m)  
<= 15 kV  
Non-operating humidity  
Altitude  
Electrostatic discharge  
Acoustic noise  
< 55 dBA  
Operating shock  
No errors with a half sine wave shock  
of 2G (with 1 millisecond duration)  
Handling drop  
2g 11 mS  
18" free-fall when packaged  
Front panel features  
The following diagram shows the front view of the server chassis with the  
bezel cover in place. When the bezel cover is removed, Drive Bay 1 is  
accessible.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
14 Chapter 2 600r server description  
Figure 1  
Front panel  
The following diagram shows the front panel controls and status LEDs.  
For more information about the front panel controls and status LEDs, see  
CallPilot 600r Server Maintenance and Diagnostics (NN44200-703.)  
Figure 2  
Front panel control switches and status LEDs  
Note: The faults described in the following table are hardware faults and  
are independent of CallPilot application faults.  
Table 1  
Front panel  
Label  
Description  
Power button  
Reset button  
Label  
Description  
A
B
M
L
NMI button (not used)  
ID button  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Server features 15  
Label  
Description  
Label  
Description  
C
D
E
F
Critical fault LED  
K
J
I
System ID LED (white)  
NIC activity LED (green)  
Main power LED (green)  
not used  
Major fault LED  
Minor fault LED  
Power LED  
H
G
Disk 0 Activity/Fault LED (green/amber)  
Rear panel controls and features  
The following diagram shows the back panel controls and features. On the  
right is the AC power supply bank. The PCI card bracket is in the middle  
of the back panel, while the connectors and ports are along the bottom  
and the left side.  
Note: Nortel provides only AC power supply. The server works with a  
DC-to-AC converter, however, you must ensure converter meets AC  
requirements as specified on label of power supply cover. To access the  
power supply cover, remove server cover. For more information about  
the server cover, see "To remove the server cover" (page 24).  
Figure 3  
Rear panel  
Table 2  
Rear panel  
Label  
Description  
Label  
Description  
A
USB 0, USB 1, USB 2  
(labelled 0, 1, 2 on the  
server)  
G
Ground studs (used with system with DC input  
power supply)  
B
C
PS/2 Mouse  
H
I
RJ45 NIC 2 Embedded Local Area Network  
(ELAN) connector for the ELAN subnet (engraved  
2 on server)  
SCSI port  
RJ45 NIC 1 Customer Local Area Network  
(CLAN) connector for Nortel server subnet  
(engraved 1 on server)  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16 Chapter 2 600r server description  
Label  
Description  
Label  
Description  
D
PCI card bracket  
J
Video connector  
(full-height) for MPB96  
E
F
Power supply  
K
L
COM1 DB-9 serial port  
AC power input  
PS/2 Keyboard connector  
PCI riser assembly  
The PCI riser assembly holds the MPB96 voice-processing card. The  
following diagram shows the PCI riser assembly above the server.  
Figure 4  
PCI riser assembly  
Network connectivity  
This section describes how the 600r server can be integrated into  
your network. The 600r can connect to legacy Meridian 1 (M1) and  
Communication Server 1000 (CS 1000) systems.  
ATTENTION  
To secure the CallPilot server from unauthorized access, ensure that the CallPilot  
network resides behind your network firewall.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Network connectivity 17  
Sample network setup: Meridian 1  
The Meridian 1 switch can be one of the following:  
Option 11C or Option 11C Mini using fiber connections  
Option 51C  
Option 61C  
Options 81 and 81C  
The following diagram shows a CallPilot 600r server network setup with  
a Meridian 1 switch.  
Figure 5  
Sample network setup with Meridian 1  
Sample network setup: Communication Server 1000  
The following diagram shows a CallPilot 600r server network setup with a  
CS 1000 system:  
Figure 6  
Sample network setup with Communication Server 1000  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
18 Chapter 2 600r server description  
In the previous diagram, the telephony LAN (TLAN) subnet provides  
IP connectivity between the CS 1000 system and the IP Phones.  
The connection between the Call Server and Media Gateway can be  
point-to-point, or it can be through the LAN, if the system is installed in  
a distributed data network.  
For information about the CS 1000 system and IP Phone bandwidth and  
network requirements, see the planning and installation documentation  
for the CS 1000 (NN430xx).  
Switch connectivity  
For more details about how the connection between the 600r server and  
the switch is established, refer to the switch and server setup document  
for your switch.  
Communication Server 1000 and CallPilot Server Configuration  
(NN44200-312)  
Meridian 1 and CallPilot Server Configuration (NN44200-302)  
LAN connectivity  
The 600r server contains two Ethernet controllers on the motherboard that  
provide the following:  
10/100Base-T Ethernet network connectivity to the ELAN subnet  
ELAN subnet is a network connection from the switch to the CallPilot  
server. The ELAN subnet is an Ethernet LAN that enables signaling  
and administration access to applications related to the Meridian 1  
switch or CS 1000 system. The ELAN subnet is an isolated 10BaseT  
subnet required for management traffic and intra-system signaling traffic  
between the system call server and any devices requiring call server  
processing. A number of configurations are available, depending on  
whether the switch has an address on the Nortel server subnet.  
For information about the ELAN subnet’s purpose and requirements,  
see the Planning and Engineering Guide (NN44200-200).  
10/100/1000Base-T Ethernet connectivity to the Nortel server subnet  
Nortel server subnet is a network set up by a customer for its data  
network. The Nortel server subnet is an optional connection that  
provides data connectivity among desktop and Web messaging clients,  
administrative PCs, and the CallPilot server. Typically, a Nortel server  
subnet already exists before CallPilot is installed at a customer site.  
Nortel recommends that the customer separate the Nortel server subnet  
from the rest of the enterprise IP network by a Layer 3 switch. The Nortel  
server subnet connects to the CLAN port on the 600r CallPilot server.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Supported peripheral devices 19  
For information about how to identify the location of the network interface  
Network requirements  
Appropriate networking equipment must be available for the ELAN subnet  
and the optional Nortel server subnet, if it is used.  
The ELAN subnet (and the optional Nortel server subnet, if used) must  
be properly configured for correct CallPilot operation. To ensure correct  
configuration, Nortel recommends that you consult a network specialist.  
Remote access connectivity  
Use the USB connection on the rear of the 600r server to connect to an  
external dial-up modem. With the modem, administrators and technical  
support personnel can administer the 600r server from a remote location.  
You can also access the 600r server from a remote location directly over the  
network, without the use of a modem.  
Supported peripheral devices  
This section identifies external devices that are supported by the 600r  
server.  
Table 3  
Supported peripheral devices  
Device  
Description  
Modem  
Use a 56 Kb/s external modem to provide remote access to the 600r server.  
The modem connects to a USB connector (USB 2, the top connector) on  
the rear of the server.  
Ethernet switch or  
hub  
A 10Base-T compliant Ethernet switch or hub provides the ELAN connection  
between the 600r server and the Meridian 1 switch or CS 1000 system. The  
customer can supply a Ethernet switch or hub from third-party vendors or from  
Nortel. Because the Ethernet switch or hub is an external device, the Ethernet  
switch or hub requires an AC power source.  
Monitor: (customer supplied). Because the monitor is an external device,  
it requires its own AC power source.  
Monitor, keyboard,  
and mouse  
Keyboard: (customer supplied)  
Mouse: (customer supplied)  
External tape drive Tandberg SLR75 (optional)  
Nortel software  
feature dongle  
The software feature dongle or key is a security device that stores the unique  
serial number of the server. The dongle plugs into a USB connector (USB 0,  
the bottom connector) on the rear panel.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
20 Chapter 2 600r server description  
Reference documents  
For a list of all CallPilot documents, see the following CallPilot Customer  
Documentation Map.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
21  
Chapter 3  
Preparing for installation  
In this Chapter  
Installation overview  
Introduction  
This section provides an overview of the steps required to install the 600r  
server and peripheral devices. For detailed instructions, see Chapter 4  
When you are finished, continue with the switch and server setup as  
described in the documentation for your switch:  
Communication Server 1000 and CallPilot Server Configuration  
(NN44200-312)  
Meridian 1 and CallPilot Server Configuration (NN44200-302)  
Installation checklist  
Description  
Step  
Check  
__  
1
Review the "Installing the CallPilot server" section in the  
Installation and Configuration Task List (NN44200-306),  
and complete stage 1 of the Installation checklist.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
22 Chapter 3 Preparing for installation  
Description  
Step  
Check  
__  
2
Unpack the server and ensure you have all the items you  
Complete the following checklists that are provided in the  
Installation and Configuration Task List (NN44200-306):  
CallPilot software media and documentation checklist  
CallPilot server hardware checklist  
__  
3
Remove the top cover and inspect the interior (see  
4
5
Replace the top cover.  
__  
__  
Place the 600r server in the chosen location and connect  
the SCSI terminator (see "Installing the server" (page 27)).  
__  
__  
6
Connect the 600r server and devices as follows:  
Connect the monitor, keyboard, and mouse (see "To  
Connect the modem (see "To connect the modem to  
__  
__  
Connect the 600r server to the ELAN Ethernet switch  
Note: If you are connecting the optional Nortel server  
subnet, do not connect until you ensure that CallPilot has  
the latest antivirus software. Do not install third-party  
antivirus software unless approved by Nortel. For  
information about the antivirus software packages that  
are approved by Nortel for CallPilot, see Product Bulletin  
P-2007-0101-Global : CallPilot Support for Anti-Virus  
Applications. Also, ensure your CallPilot application  
resides behind your network firewall.  
Connect the 600r server to the CLAN Ethernet switch  
or hub (optional); (see "Connecting the server to the  
__  
Install the software feature dongle (see "Installing the  
__  
__  
Connect the power cords for all peripheral devices, and  
then power them up (see "Connecting the server to  
power" (page 40) for power requirements).  
7
__  
Start the 600r server (see "What is next?" (page 43)).  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking the 600r server 23  
Unpacking the 600r server  
Introduction  
Follow this procedure to unpack the server and peripherals.  
WARNING  
Risk of personal injury  
The 600r CallPilot server weighs approximately 10 kg (23 lbs) as  
shipped from manufacturing. If necessary, and to prevent personal  
injury, ask someone to help you unpack and position the server.  
To unpack the equipment  
ATTENTION  
As you unpack each item, check it off against the packing list, as well as against  
the following checklists provided in the Installation and Configuration Task List  
(NN44200-306):  
CallPilot software media and documentation checklist  
CallPilot server hardware checklist  
Step Action  
1
2
3
Carefully open the cardboard carton containing the server.  
Remove the server from the carton and place on a secure surface.  
Carefully open the cartons containing the monitor, keyboard, mouse,  
modem, and ELAN Ethernet switch or hub (if supplied), and set the  
peripherals aside.  
4
5
Put all manuals, DVD/CD/CDRWs, operating system disks, and any  
disks for peripherals in a safe place.  
Save all packing materials and cartons in case you must return any  
equipment to the carrier.  
—End—  
What is next?  
Remove the top cover to inspect the interior of the server. For information  
about how to inspect the interior of the server, see "Inspecting the interior  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
24 Chapter 3 Preparing for installation  
Inspecting the interior of server  
Introduction  
To inspect the interior of your 600r server, you must remove the server cover.  
Note: If the server is powered down, proceed with the next step. If  
the server if powered up, see the chapter, "Starting up and shutting  
down the CallPilot server", in Installation and Configuration Task List  
(NN44200-306) for proper shutdown procedures before you remove  
the server cover.  
To remove the server cover  
Step Action  
1
2
Attach the ESD strap to your wrist.  
While holding in the blue button at the top of the chassis, slide the  
top cover back until it stops.  
3
4
5
6
Lift the cover straight up to remove it from the platform.  
Ensure the CallPilot PCI riser card is secure.  
Inspect the interior for any cables that are not seated properly.  
Take note of any physical signs of damage. For example, check for  
loose piece parts and screws in the corners of the chassis.  
7
If you notice damage to any of the parts in your server, contact your  
Nortel representative immediately.  
—End—  
To replace the server cover  
When you finish inspecting the interior of your server, replace the server  
cover.  
Step Action  
1
2
3
Attach the ESD strap to your wrist and attach the other end to a  
known grounded connection.  
Place the cover on the server and align the cover with the chassis  
tab guides.  
Slide the top cover back until it stops.  
—End—  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Inspecting the interior of server 25  
What is next?  
Continue with the hardware installation, Chapter 4 "Installing the server and  
peripheral devices" (page 27). Or, for more information, see "Installation  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
26 Chapter 3 Preparing for installation  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
Chapter 4  
Installing the server and peripheral  
devices  
In this chapter  
Installing the server  
Before you install the 600r server, ensure that the chosen location meets  
the requirements identified in the Site inspection checklist provided in the  
Installation and Configuration Task List (NN44200-306).  
Note: The 600r server is supplied with industry standard 48.3 cm (19  
in.) rack rails that can accommodate racks with a maximum depth of 61  
cm (24 in.) between the mounting posts. Check the rack you are using  
and ensure that the Nortel supplied server rack rails are suitable for your  
specific installation requirements. For depths greater than 61 cm (24  
in.), Nortel recommends that you purchase a third-party rack shelf that  
can safely hold up to 23 kg (50 lb.)  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
28 Chapter 4 Installing the server and peripheral devices  
To install the server  
Step Action  
1
Place the 600r server in its chosen location. If you are installing  
the server in a rack cabinet, follow the instructions provided with  
the slide rails.  
Note: The DS30X cable that connects the NTRH40AA MPB96  
board to the MGate cards is 20 m (60 feet) long. With this cable,  
you can place the server in a different room from the Meridian  
1 switch or CS 1000 system.  
The DS30 cables that connect the NTRH40CA MPB96 board to  
the NTRB18DA MGate cards can be up to 600 m (1968 feet)  
long. With this cable you can place the server in a different  
building from the Meridian 1 switch or CS 1000 system.  
2
Locate the external SCSI terminator (included loose within the  
server shipping carton). Connect the terminator to the rear SCSI  
port labeled C in Figure 7 "Rear panel" (page 29). For an illustration  
of the SCSI terminator, see the item labeled Server terminator in  
CAUTION  
It is imperative that you install the terminator to ensure reliable  
server operation. Failure to do so will result in an inability to load  
the operating system.  
3
Connect peripheral devices as described in this chapter.  
—End—  
What is next?  
Connect peripheral devices as described in this chapter.  
Connecting peripherals to the server  
Rear panel connectors  
The following diagram shows the connectors on the rear panel of the 600r.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Connecting peripherals to the server 29  
Figure 7  
Rear panel  
Table 4  
Rear panel connectors  
Label  
Description  
Label  
Description  
A
USB 0, USB 1, USB 2  
(labelled 0, 1, 2 on server)  
G
Ground studs (used with system with DC input  
power supply)  
B
C
D
PS/2 Mouse  
SCSI port  
H
I
RJ45 NIC 2 ELAN connector (labelled 2 on  
server)  
RJ45 NIC 1 CLAN connector (labelled 1 on  
server)  
PCI card bracket (full-height)  
for MPB96  
J
Video connector  
E
F
Power supply  
K
L
COM1 DB-9 serial port  
AC power input  
PS/2 Keyboard connector  
To connect the mouse, keyboard, and monitor to the server  
Step Action  
1
2
Place the monitor, keyboard, and mouse in the same location as  
the server.  
Plug the keyboard and mouse into the appropriate PS/2 connectors  
on the chassis rear panel. See labels L and B, respectively, on the  
diagram.  
3
4
5
Plug in the monitor connector (see diagram, label J). Tighten the  
screws on the connector.  
Connect the power cord to the monitor and plug the other end into  
a wall receptacle or power bar.  
Turn on the monitor.  
—End—  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
30 Chapter 4 Installing the server and peripheral devices  
To connect the modem to the server  
You require a modem to support remote dial-up access to the CallPilot  
server. With a modem, Nortel technical support can connect to your  
CallPilot server for troubleshooting purposes. Nortel connects to your server  
only when you request technical assistance.  
Windows automatically recognizes your modem after you connect it and  
power it on. The power light (PWR LED) does not illuminate until the  
Windows device driver successfully loads and recognizes the hardware.  
To install the modem, you need the following equipment:  
USB modem  
RJ-11 analog phone cord  
USB cable (supplied with the modem)  
an analog line jack  
Serial port modems with RS-232 connections are not supported on the 600r.  
Step Action  
1
2
3
Connect one end of the USB cable into the modem.  
Connect the other end of the USB cable into USB 2 on the rear panel.  
Connect one end of the telephone cable to the modem RJ-11 jack  
labeled LINE.  
4
Connect the other end of the telephone cable to the RJ-11 jack in  
the wall.  
—End—  
To connect the external SCSI tape drive  
When you connect an external SCSI tape drive, the device must be  
terminated. Your tape drive comes with a terminator. (See Tape drive  
600r server also comes with a server terminator, a VHDCI (Very High  
Density Connection Interface) Ultra320 SCSI terminator. (See Server  
previous procedure, you are instructed to connect the server terminator to  
the SCSI port. Before you connect an external tape drive to the 600r, you  
must remove the server terminator.  
Note: If you do not connect a SCSI device to the server, do not remove  
the server terminator from the SCSI port.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connecting peripherals to the server 31  
WARNING  
The terminator is not a hot-plug device. If you replace the  
terminator, or if you add an external SCSI peripheral, the server  
must be powered off. If you replace the terminator or add a SCSI  
peripheral when the system is on, the system can crash.  
Step Action  
1
Power off the server and the tape drive.  
Note: For the proper shutdown procedure, see the chapter,  
"Starting up and shutting down the CallPilot server" in Installation  
and Configuration Task List (NN44200-306).  
2
3
Set the SCSI ID push button switch, located on the back of the tape  
drive, to 6.  
Connect the external SCSI tape drive to the SCSI port in the rear  
panel, Label C on the rear panel diagram, as shown in Figure 7  
Note: You must remove the server terminator before you  
connect the tape drive to the server. Keep the server terminator  
in a safe place, as you may need the server terminator when  
you want to use the server, and the tape drive is not available to  
terminate the SCSI bus.  
Figure 8  
SCSI tape drive with terminator  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
32 Chapter 4 Installing the server and peripheral devices  
4
Install the SCSI tape drive terminator to the back of the SCSI tape  
drive, as shown in Figure 8, under the label Tape drive terminator.  
Note: Nortel does not recommend connecting older SCSI  
protocol terminators, as this can affect server performance.  
5
6
Plug the tape drive into the same single point ground and A/C power  
as the rest of the system.  
Power on the tape drive.  
Note: Your 600r comes with the tape drive drivers preinstalled.  
During the loading of Windows, the system automatically detects  
the tape drive and loads the drivers that are necessary to operate  
the tape drive. When system startup is complete, the tape drive  
is ready for use.  
—End—  
What is next?  
Connect the server to the ELAN subnet and Nortel server subnet (if  
applicable).  
Note: Before you connect to the network, ensure that CallPilot has the  
latest antivirus software. Do not install third-party antivirus software  
unless approved by Nortel. For information about the antivirus software  
packages that are approved by Nortel for CallPilot, see Product Bulletin  
P-2007-0101-Global : CallPilot Support for Anti-Virus Applications. Also,  
ensure your CallPilot application resides behind your network firewall.  
Connecting the server to the ELAN subnet  
Connect the CallPilot server to the Meridian 1 switch or CS 1000 system  
using the ELAN subnet.  
ATTENTION  
For important considerations about using the ELAN subnet in your network, see  
the Planning and Engineering Guide (NN44200-200).  
To connect the server to the ELAN subnet (Meridian 1 or CS 1000 only)  
Step Action  
1
On the back of the server, locate the ELAN Ethernet connector.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connecting the server to the Nortel server subnet (optional) 33  
Note: The ELAN connector is labeled 2 on the rear panel of the  
server. For the connector location, refer to diagram Figure 12  
"Rear panel" (page 40), label H on the diagram.  
2
Connect an RJ-45 network cable from the ELAN Ethernet switch or  
hub to the server’s ELAN connector.  
Note: The ELAN Ethernet switch or hub is optional if you  
use a crossover network cable to make a direct point-to-point  
connection from the server to the switch. However, if you choose  
to establish a direct point-to-point ELAN connection, no other  
device can connect to the ELAN subnet. For specific connection  
details, see the CS 1000 network documentation.  
—End—  
What is next?  
If the server  
is connected to a Nortel server  
subnet  
Then  
is not connected to a Nortel server continue with installing the software feature  
subnet  
Connecting the server to the Nortel server subnet (optional)  
This section provides instructions to connect the server to the Nortel server  
subnet.  
Note: The CLAN connection is optional. However, connection to  
a Nortel server subnet is required for support of desktop and Web  
messaging users, or administration by means of a Web-enabled PC.  
Ensure that CallPilot has the latest antivirus software. Do not install  
third-party antivirus software unless approved by Nortel. For information  
about the antivirus software packages that are approved by Nortel for  
CallPilot, see Product Bulletin P-2007-0101-Global : CallPilot Support  
for Anti-Virus Applications.  
Media Access Control address  
The Media Access Control (MAC) address is a unique number assigned to  
network cards and controllers. You can find the MAC address bar code label  
located on top of the chassis, directly above the front main push-button  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
34 Chapter 4 Installing the server and peripheral devices  
power switch. Two MAC addresses are shown on the label. The CLAN  
MAC address is the top MAC address, labeled MAC1, while the ELAN MAC  
address is labelled MAC2.  
To connect the server to the Nortel server subnet  
Step Action  
1
On the back of the server, locate the CLAN connector.  
Note: The CLAN connector is labeled 1 on the rear panel of the  
600r. For the connector location, see the diagram on Figure 7  
2
Connect an RJ-45 network cable from the CLAN Ethernet switch  
or hub to the CLAN connector.  
Note: When connecting the optional Nortel server subnet, do  
not connect to the network until you ensure that CallPilot has  
the latest antivirus software. Do not install third-party antivirus  
software unless approved by Nortel. For information about the  
antivirus software packages that are approved by Nortel for  
CallPilot, see Product Bulletin P-2007-0101-Global : CallPilot  
Support for Anti-Virus Applications. Also, ensure your CallPilot  
application resides behind your network firewall.  
—End—  
What is next?  
Installing the Nortel software feature dongle  
The software feature key is a security device that stores the unique serial  
number of the server. The feature key is embedded in the Nortel software  
feature dongle that plugs in to a USB port on the rear panel.  
The following diagram shows the dongle plugged in to the back panel of  
the server:  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the Nortel software feature dongle 35  
Figure 9  
Dongle plugged in to server  
To install the software feature dongle  
Step Action  
1
2
On the rear panel, ensure that there is nothing plugged in to USB 0,  
the bottom USB connector.  
If the software feature key is not preinstalled in the dongle, insert the  
key in to the software feature slot in the dongle.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
36 Chapter 4 Installing the server and peripheral devices  
Figure 10  
Dongle without feature key  
a. To open the dongle to insert the software feature key, gently push  
back the clip on side of the dongle using a very small screwdriver  
and pull back on the access door.  
b. Insert the software feature key with the data contact facing down  
and away from the embossed i. (For more information about  
installing the software feature key, see Figure 11 "Installing the  
Figure 11  
Installing the software feature key  
3
Remove the front protection cover from the dongle.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Nortel software feature dongle 37  
4
Plug the dongle in to USB port 0, the bottom USB connector, on the  
rear panel of the server.  
Note: Due to system driver allocations, the dongle must be  
installed in USB port 0.  
—End—  
What is next?  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
38 Chapter 4 Installing the server and peripheral devices  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
Chapter 5  
Connecting the server to power  
In this chapter  
Safety precautions  
Equipment handling guidelines  
External power equipment, such as an Uninterruptible Power Supply  
(UPS), is usually very heavy. This equipment requires special handling  
procedures and additional personnel for unloading and installation. Be  
aware of weight distribution, and prevent the equipment room floor from  
being overly stressed.  
Safety information  
DANGER  
Procedures involving electrical connections must be performed  
only by qualified personnel. Ensure that you obey all displayed  
warning notices on power equipment and connections.  
Locating the power supply modules  
Introduction  
The AC power supply module is shipped installed. The following diagram  
shows the location of the power supply module in the back panel (E).  
Note: Nortel provides only AC power supply. The server works with a  
DC-to-AC converter, however, you must ensure the converter meets  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
40 Chapter 5 Connecting the server to power  
AC requirements as specified on the label of the power supply cover.  
To access the power supply cover, remove the server cover. For more  
information about how to remove the server cover, see "To remove the  
Figure 12  
Rear panel  
About the power supply module  
After the server is powered up, the power supply module LED indicates its  
status.  
A green LED on the power supply module indicates that the module is  
working properly. If the LED is not lit or red, the module has failed to power  
up. A problem with a power supply module is also indicated if the PWR or  
MJR LED light on the front of the server is red.  
Rack power and grounding  
To ensure a complete power and grounding installation:  
In rack-mount server installations, ensure the CallPilot server chassis  
and equipment racks are isolated from other foreign sources of ground.  
Acceptable isolation methods include: isolation pads, grommeted  
washers, chassis side-rail strips, and non-conducting washers (not  
included.)  
In rack-mount server installations where other equipment is also  
installed in the same rack, ensure that all equipment derives ground  
from the same service panel as CallPilot and the switch.  
Connecting the server to power  
Before you begin  
Ensure that proper power and grounding are available for all the power  
outlets serving the CallPilot server and its associated peripherals. Power  
for these devices must be wired and fused independently of all other  
receptacles and referenced to the same ground as the PBX system.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connecting the server to power 41  
A qualified electrician must implement the single-point ground reference as  
required among the power outlets of the CallPilot server, its associated  
peripherals, and the power outlets of the switch.  
Provide a sufficient number of properly grounded power outlets or power  
bars for all equipment.  
The single-point ground (SPG) required by the system can be an isolated  
ground (IG) bus or AC equipment ground (ACEG) bus in the service  
panel or transformer. The system must be connected to safety ground or  
protective earth in accordance with NEC requirements. For international  
use, the system must be connected to safety ground or protective earth in  
accordance with Paragraph 2.5 of EN60950/IEC950.  
Note: For a complete description of approved ground sources and  
methods, seeCommunication Server 1000M and Meridian 1: Large  
System Planning and Engineering (NN43021-220). Insulated ground  
wire must be used for system grounding.  
Before you connect the server to the power source, review the following  
diagram and the warning that follows to ensure that all peripheral hardware  
devices are in place.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
42 Chapter 5 Connecting the server to power  
Figure 13  
Example setup of 600r with peripherals  
To connect the 600r server to power  
WARNING  
Risk of personal injury and risk of hardware failure  
You must connect the power outlets that are used by the CallPilot  
server and its peripheral devices to the same single-point ground  
reference as the one used by the switch with MGate cards  
connected to the CallPilot server.  
If this requirement is not met, power transients can cause  
personal injury, hardware failure, or both. For more information  
about single-point grounding requirements, seeInstallation and  
Configuration Task List (NN44200-306).  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connecting the server to power 43  
Note: When the 600r server is plugged into an AC outlet with power,  
the server automatically powers on. If there is a power outage and the  
600r server loses power, the server automatically powers up after power  
is restored.  
Step Action  
1
2
Plug the server AC power cord into the server rear panel.  
Plug the other end into an approved wall receptacle or power bar.  
—End—  
What is next?  
Proceed to the Installation and Configuration Task List (NN44200-306) for  
details.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
44 Chapter 5 Connecting the server to power  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
45  
Chapter 6  
EMC emission level protection for the  
600r server  
To lower the EMC emission level, ferrite cores are installed with one loop on  
the following external cables:  
Ferrite Core (TDK and part number ZCAT3035-1330) for the triple  
DS30X I/O cable (Nortel and part number NTRH2014E6), at each end  
of the cable.  
CAUTION  
The ferrite cores are preinstalled on the provided cable. It is not  
your responsibility to attach these ferrite cores to these cables.  
However, you must ensure that these ferrites are in place to keep  
the EMC emission levels low.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
46 Chapter 6 EMC emission level protection for the 600r server  
Figure 14  
Ferrite cores secured to an external cable  
Ferrites  
Connectors for the  
MGate cards  
Connector for the  
MPB96 board  
G101786  
The ferrite cores are secured to the appropriate cable with plastic enclosure  
clips. Tie wraps are added to the cable loop.  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
47  
Index  
Nortel server subnet 18  
remote access 19  
Customer LAN  
Symbols/Numerics  
600r server  
connections  
CLAN 33  
establishing 37  
power 37  
dimensions 12  
D
DC power input 29  
devices, peripheral 19  
diagrams  
ELAN  
connection, establishing 32  
environmental specifications 13  
front panel, description 13  
installing 28  
Nortel server subnet  
connection, establishing 34  
peripheral devices, connecting 28  
power connection, establishing 42  
rear panel, description 28  
server cover  
CallPilot network connections  
Communication Server 1000 17  
Meridian 1 17  
front panel 13  
rear panel 15, 28  
server cover  
replacing 24  
software feature key adapter 35  
TLAN subnet (Communication Server  
1000) 17  
replacing 24  
unpacking 23  
dimensions, 600r server 12  
dongle 34  
600r server cover  
removing 24  
replacing 24  
E
ELAN subnet  
A
connecting server to 32  
Embedded LAN  
ELAN 32  
adapter, software feature key 35  
C
environmental specifications, 600r server 13  
checklist, installation 21  
COM1 connection, description 19  
Communication Server 1000, CallPilot  
network setup 17  
F
fax modem  
required equipment 30  
front bezel  
connectivity  
ELAN 18  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
48 Index  
replacing 24  
front panel, description 13  
S
serial number 34  
server 24  
K
connections  
keyboard  
establishing 37  
connecting to the server 29  
power 37  
cover  
removing 24  
dimensions 12  
ELAN  
L
LAN connections, description 18  
connection, establishing 32  
environmental specifications 13  
front panel, description 13  
installing 28  
Nortel server subnet  
connection, establishing 34  
peripheral devices, connecting 28  
power connection establishing 42  
rear panel, description 28  
replacing 24  
M
Meridian 1, CallPilot server network  
setup 17  
modem  
connecting to the server 30  
required equipment 30  
monitor  
connecting to the server 29  
mouse  
connecting to the server 29  
serial number 34  
unpacking 23  
N
server cover  
removing 24  
replacing 24, 24  
network  
controllers 18  
single-point grounding, power  
requirement 42  
slot locations 15  
software feature key 34  
software feature key adapter  
description 35  
protocols 18  
setup, CallPilot  
Communication Server 1000 17  
Meridian 1 17  
Nortel server subnet  
connecting server to 34  
installing 35  
specifications, environmental 13  
P
peripheral devices 19  
connecting to the server 28  
power  
T
telephony LAN  
TLAN subnet 18  
TLAN subnet, diagram 17  
top cover  
connecting server to 42  
grounding, requirement 42  
protocols, supported network 18  
replacing 24  
R
U
rear panel, description 15, 28  
remote access connectivity 19  
unpacking 23  
USB connection 19  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index 49  
W
warnings, conventions 11  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
50 Index  
Nortel CallPilot  
600r Server Hardware Installation  
NN44200-307 01.03 Standard  
5.0 14 May 2008  
Copyright © 2007-2008, Nortel Networks  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Nortel CallPilot  
600r Server Hardware Installation  
Copyright © 2007-2008, Nortel Networks  
All Rights Reserved.  
Publication: NN44200-307  
Document status: Standard  
Document version: 01.03  
Document date: 14 May 2008  
To provide feedback or report a problem in this document, go to www.nortel.com/documentfeedback.  
Sourced in Canada  
The information in this document is subject to change without notice. The statements, configurations, technical data, and  
recommendations in this document are believed to be accurate and reliable, but are presented without express or implied  
warranty. Users must take full responsibility for their applications of any products specified in this document. The information in  
this document is proprietary to Nortel Networks.  
*Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks.  
*Microsoft, MS, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation.  
All other trademarks and registered trademarks are the property of their respective owners.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Lawn Mower 970 979 User Manual
New Buck Corporation Indoor Fireplace DV23ZC User Manual
NordicTrack Treadmill NTL10850 User Manual
NordicTrack Treadmill NTL108051 User Manual
Omega Thermometer OS642C LS User Manual
Onkyo Stereo Receiver TX NR809 User Manual
Oregon Scientific Camcorder DV 80005 User Manual
Oritron Home Theater System ICS 2100 User Manual
P3 International Pest Control Equipment P7810 PIR User Manual
Patterson Kelley Boiler MOD 04 User Manual