Fiber connection: ST connectors
Fiber optic cable
Features
Complies with IEEE 802.3 10Base-FL standard.
A complete interface of the AUI to fiber optic cable link.
Flexible selection for half-duplex or full-duplex mode
Supports data transfer rate up to 20Mbps for full-duplex
Capability for driving the fiber optic cable segment up
to 2000M (6560 ft.).
Two ST style connectors are provided for connection to
fiber optic cable. One is for transmitting and the other is
for receiving. See the following figure:
Installation Guide
Ethernet Fiber Optic Transceiver
Model: KT-10F v2
Selectable SQE test function
Link integrity test for automatic checking of fiber
optic cable lines
Supports LED indications for the Transmit, Receive,
Link, and Collision status.
Dimension:
Input voltage: 10.2 to 15.75 VDC
42mmx65mmx20mm
Fiber mode: multimode
Wavelength: 850µm
Input current: 250mA @12 VDC (typical)
The transceiver can operate with a variety of fiber optic
sizes, for example, 50/125µm, 62.5/125µm, and 100/140µm.
Connectors & Cables
DOC.G990126-KT10F-V2-K
P/N: 750-0125-001
AUI connection: D-sub 15 pin male connector
AUI drop cable (50 meters max.)
Setting Switches
There are two switches which are accessible on the side of
the transceiver enclosure. The functions of these switches
are:
The AUI connector is used for attaching the transceiver to
the AUI port provided by an Ethernet device such as an
Ethernet MAC controller, an Ethernet repeater, or an
Ethernet concentrator via an AUI drop cable. The pin
assignments are shown as below:
General Description
The KT-10F Ethernet transceiver complies with IEEE 802.3
transceiver specifications and 10Mbps Ethernet CSMA/
CD operation to extend the your existing Ethernet segment
up to 2000 meters by using fiber optic cable.
SW# Setting
SW1 On
Off
SW2 On
Off
Function
Enable SQE test (factory default)
Disable SQE test (for repeater device)
Full-duplex mode
The transceiver is attached to the AUI connector of an
Ethernet device via standard AUI cable.
Half-duplex mode (factory default)
Pin Assignments of the AUI (DB15) Connector
Pin
3
Name
DO +
DO -
DO S
DI +
DI -
DI S
CO +
CO -
CO S
CI +
CI -
Pairs
Use
Transmit
Pair
Data Out (+)
Data Out (-)
Data Out Shield
Data In +
Important:
10
11
5
12
4
The transceiver is shipped from the factory with the SQE
test enabled. If the transceiver is connected to an Ethernet
repeater, a 10Base-T hub, or a wiring concentrator, the SQE
test function should be disabled.
Receive
Pair
Data In -
Data In Shield
Control Out +
Control Out -
Control Shield
Control In +
Control In -
7
15
8
Optional
Pair
2
9
Collision
Pair
1
6
13
14
CI S
VC
VP
Control Shield
Voltage Common
Voltage Plus
Voltage Shield
Power
Pair
VS
Download from Www.Somanuals.com. All Manuals Search And Download.
|