Operation Manual
BDN 14x50
Day / Night Binoculars
105 Sparks Ave., Toronto ON, M2H 2S5
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES
This optical instrument utilizes unique optical scheme to that enables
observer to use the high magnification binoculars 24 hours a day,
eliminating the need for separate day and night optics.
•
•
•
•
•
•
Day / Night round the clock model
High magnification with large objective lens
Rigid construction
Weather proof, water resistant
Wide field of view
Easy switch between day and night modes
SPECIFICATIONS
Day
14.0
4.7
Night
5
14.7
Magnification
Field of view, °
Objective lens diameter, mm
Dioptric correction
Typical resolution of the Image
Intensifier Tube (IIT), lp/mm
Interpupillary distance adjustment
range, mm
50
±5
45-72
55-74
Operating temperature, °C
Battery
-40°C to +55°C
2xAA
Dimensions, mm
Weight, g
235х 168 х 74
1,500
2
Download from Www.Somanuals.com. All Manuals Search And Download.
DESIGN AND APPEARANCE
1 – Body
2 – Day / night switch
3 – Eyepieces
5 – Battery compartment with cap
7 – Objective lens caps
4 – Eyepiece dioptric adjustment knobs
6 – Rubber grip
OPERATION DURING DAY
• Unpack the unit from the soft case, trying to keep the lenses closed
by caps.
• Make sure that the switch (2) is set to “D” position.
• Remove the objective caps (7). Aim the unit to the observed object.
• The eye cups can be folded as shown below for eyeglasses wearers.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
• Adjust the distance between the eyes by turning both eyepiece
assemblies (3) until two images converge into one. This adjustment is
made tough intentionally to provide for a water resistance.
• Adjust the focus individually for each eye using the focus adjustment
knobs (4).
• put on the objective lens caps after you finish observation.
OPERATION DURING NIGHT
• Unpack the unit from the soft case.
• If the batteries were not installed, unscrew the battery cap (5) and
install the batteries, observing correct polarity as drawn schematically
on the body (1) (“-“ towards the bottom of the compartment).
• The eye cups can be folded as shown below for eyeglasses wearers.
• Remove the objective lens caps (7). Aim the unit to the observed
object.
• Flip the switch (2) into “N” position. You will see greenish light through
the eyepieces with outlines of the observed object.
• Adjust the distance between the eyes by turning both eyepiece
assemblies (3) until two images converge into one. This adjustment is
made tough intentionally to provide for a water resistance.
• Adjust the focus individually for each eye using the focus adjustment
knobs (4).
• Put on the objective lens caps and flip the switch into “D” position
after you finish observation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
NEWCON warrants this product against defects in materials and
workmanship for one year from the date of the original purchase, but no
more than 18 months from the date of manufacturing. Longer warranty is
available, subject to the terms of the specific sales contract. Should your
Newcon product prove to be defective during this period, please deliver
the product securely packaged in its original container or an equivalent,
along with the proof of the original purchase date, to your Newcon
Dealer.
Newcon will repair (or, at its option, replace with the same or comparable
model), the product or part thereof, which, on inspection by Newcon, is
found to be defective in materials or workmanship.
What This Warranty Does Not Cover:
NEWCON is not responsible for warranty service should the product fail
as a result of improper maintenance, misuse, abuse, improper
installation, neglect, damage caused by disasters such as fire, flooding,
lightning, improper power supply, or service other than by a NEWCON
Authorized Service.
Postage, insurance, and shipping costs incurred while presenting your
NEWCON product for warranty service are your responsibility.
If shipping from North America, please, include a cheque or money order
payable to NEWCON OPTIK for the amount of $15.00 to cover handling
and return shipping.
CUSTOMER SUPPORT
Should you experience any difficulties with your Newcon Optik product,
consult this manual first.
If the problem remains, contact our customer support department at
+1(416) 663-6963 or toll free at 1-877-368-6666 (North America only).
Our operating hours are 9am-5pm, Monday - Friday, Eastern Standard
Time.
Under no circumstances should the equipment be sent to Newcon
without authorisation from our technical support department.
Newcon accepts no responsibility for unauthorized returns.
To locate NEWCON Authorized Dealer call +1(416) 663-6963 or fax
+1(416) 663-9065, email: [email protected]
The defective products should be shipped to:
From the USA only:
2331 Superior Ave. Cleveland, OH 44114, USA
From all other countries:
105 Sparks Ave., Toronto ON, M2H 2S5, CANADA
5
Download from Www.Somanuals.com. All Manuals Search And Download.
QUALITY ACCEPTANCE CERTIFICATE
Image Intensifier Tube Serial Number: _______________________
Min
45
Measured
Resolution, lp/mm
Photocathode sensitivity,
500
integral, μA/ lm
Light amplification
25,000
BDN 14x50 serial number _____________________________
This Day / Night Binoculars BDN 14x50 meet all technical specifications
and have passed the inspection.
Date of production: ___________
Quality Inspector signature: __________________________
Quality Assurance Seal
6
Download from Www.Somanuals.com. All Manuals Search And Download.
NEWCON OPTIK ™ 2010
Printed in Canada
Download from Www.Somanuals.com. All Manuals Search And Download.
|