Network Technologies Switch SM nXm C5AV LCD User Manual

1275 Danner Dr Tel:330-562-7070  
R NETWORK  
Fax:330-562-1999  
TECHNOLOGIES Aurora, OH 44202  
INCORPORATED  
NTI  
VEEMUX® Series  
SM-nXm-C5AV-LCD  
Audio/Video Matrix Switch via CAT5  
Installation and Operation Manual  
Used with NTI ST-C5VA-600 (XTENDEXTM) (NOT INCLUDED)  
MAN050 Rev 4/10/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
INTRODUCTION.............................................................................................................................................................1  
Materials ......................................................................................................................................................................1  
Default User Name and Passwords ............................................................................................................................2  
FEATURES AND FUNCTIONS.......................................................................................................................................2  
VEEMUX Features and Functions...............................................................................................................................2  
XTENDEX Features and Functions.............................................................................................................................3  
XTENDEX INSTALLATION.............................................................................................................................................4  
Audio Compatibility......................................................................................................................................................4  
The Local Unit..............................................................................................................................................................4  
The Remote Unit..........................................................................................................................................................6  
Plug-in and Boot Up.....................................................................................................................................................7  
VEEMUX INSTALLATION...............................................................................................................................................8  
USING THE VEEMUX SWITCH ...................................................................................................................................10  
Front Panel Interface Overview.................................................................................................................................10  
Keypad Control..........................................................................................................................................................11  
Configuration Menu ................................................................................................................................................11  
Set Serial Address ..................................................................................................................................................12  
Set Serial Speed.....................................................................................................................................................12  
Set IP Address........................................................................................................................................................12  
Set Subnet Mask.....................................................................................................................................................12  
Set Default Gateway...............................................................................................................................................12  
Set Wserver Timeout..............................................................................................................................................13  
Adjust Contrast .......................................................................................................................................................13  
Video Adjustment....................................................................................................................................................13  
Show Size...............................................................................................................................................................13  
Displaying Audio Level (Digital VU-Meter) .............................................................................................................13  
RS232 Interface.........................................................................................................................................................14  
Matrix Switcher's Control Program For Windows 9X, NT, 2000 and XP................................................................15  
Telnet Interface..........................................................................................................................................................16  
Web Interface ............................................................................................................................................................17  
Enter the Password ................................................................................................................................................17  
Switch Page.........................................................................................................................................................18  
Setup Pages ........................................................................................................................................................20  
Video Input Names..............................................................................................................................................21  
Video Output Names ...........................................................................................................................................21  
Update Firmware.................................................................................................................................................22  
Change Password Page......................................................................................................................................23  
Help Page............................................................................................................................................................23  
Update Web Server.............................................................................................................................................23  
Logout Page ........................................................................................................................................................24  
DEVICE DISCOVERY TOOL........................................................................................................................................25  
INTERCONNECTION CABLE WIRING METHOD .......................................................................................................26  
CAT5 Cable ...............................................................................................................................................................26  
Null Modem Cables ...................................................................................................................................................26  
TROUBLSHOOTING.....................................................................................................................................................27  
APPENDIX ....................................................................................................................................................................27  
WARRANTY INFORMATION........................................................................................................................................29  
TABLE OF FIGURES  
Figure 1- Connect the Local Unit to the CPU.....................................................................................................................................4  
Figure 2- Connect Local User Components to Local Unit..................................................................................................................5  
Figure 3- Connect the Extended Components to the Remote Unit....................................................................................................6  
Figure 4- Connect the AC adapters ...................................................................................................................................................7  
Figure 5- Attach ST-C5VA-600 Local Unit to VEEMUX .....................................................................................................................8  
Figure 6- Attach ST-C5VA-600 Remote Unit to VEEMUX .................................................................................................................8  
ii  
MAN050 Rev 4/10/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7- Maximum total CAT5 cable length cannot exceed 600 feet................................................................................................9  
Figure 8- Connect VEEMUX to LAN..................................................................................................................................................9  
Figure 9- Connect user terminal to VEEMUX ....................................................................................................................................9  
Figure 10- Front panel Interface LCD and keypad...........................................................................................................................10  
Figure 11- VEEMUX start-up message on LCD...............................................................................................................................10  
Figure 12- Connections screen on LCD, displays 8 sets at a time...................................................................................................10  
Figure 13- Configuration menu on LCD ...........................................................................................................................................11  
Figure 14- Set Serial Address from LCD and keypad......................................................................................................................12  
Figure 15- Set baud rate from LCD and keypad ..............................................................................................................................12  
Figure 16- Set IP Address from LCD and keypad............................................................................................................................12  
Figure 17- Wserver Timeout Period.................................................................................................................................................13  
Figure 18- Adjust LCD contrast........................................................................................................................................................13  
Figure 19- View Output audio level..................................................................................................................................................13  
Figure 20- Web interface Welcome page.......................................................................................................................................17  
Figure 21- Web interface Login Prompt ...........................................................................................................................................17  
Figure 22- Web interface Switch page.............................................................................................................................................18  
Figure 23- Web interface Setup page..............................................................................................................................................20  
Figure 24- Web interface Serial Setup page....................................................................................................................................20  
Figure 25- Web interface Video Input Names page.........................................................................................................................21  
Figure 26- Web interface Video Output Names page ......................................................................................................................21  
Figure 27- Web interface Update Firmware page............................................................................................................................22  
Figure 28- Web interface Password page........................................................................................................................................23  
Figure 29- Updating the Web Server ...............................................................................................................................................23  
Figure 30- Web interface Logout page.............................................................................................................................................24  
Figure 31- Device Discovery Tool page...........................................................................................................................................25  
Figure 32- View looking into RJ45 female........................................................................................................................................26  
Figure 33- Mount Switch to a Rack..................................................................................................................................................28  
APPENDICES  
Appendix A- Default Settings...........................................................................................................................................................27  
Appendix B- General Information.....................................................................................................................................................27  
Appendix C- Distances and Resolutions for CAT5/CAT5e and CAT6 Cables .................................................................................28  
Appendix D- Product Dimensions....................................................................................................................................................28  
Appendix E- Rack mounting Instructions .........................................................................................................................................28  
Download from Www.Somiainiuals.com. All Manuals Search And Download.  
MAN050 Rev 4/10/06  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
INTRODUCTION  
The SM-nXm-C5AV-LCD (VEEMUX) is an Audio/Video Matrix switch via CAT5 designed to work in conjunction with the  
NTI ST-C5VA-600 or ST-C5SVA-600 CAT5 Audio/Video Extender (XTENDEX). Up to 32 audio/video sources can be connected  
to the VEEMUX via XTENDEX Local Units (n), each accessible by up to 16 audio/video displays connected via XTENDEX  
Remote Units (m).  
The VEEMUX enables connections from any single XTENDEX Local Unit to any or all of the connected XTENDEX  
Remote Units, creating a matrix of possible CAT5 audio/video connections. Audio/video displays can be located up to 600 feet  
away from the connected source.  
The available models are:  
SM-8X8-C5AV-LCD  
SM-8X16-C5AV-LCD  
SM-16X8-C5AV-LCD  
SM-16X16-C5AV-LCD  
SM-32X8-C5AV-LCD  
SM-32X16-C5AV-LCD  
Features  
Up to 16 audio/video displays may be connected to up to 32 audio/video sources (via ST-C5VA-600 Extenders)  
Multiple methods of user setup and control:  
ƒ
ƒ
Front Panel Interface with LCD and keypad  
Web Interface with multiple pages with secure socket layer (SSL) encryption to provide secure access between the client  
browser and central server. Supports SSLV3/TLSV1 protocol.  
ƒ
ƒ
Telnet Interface  
RS232 Interface  
Digital VU-Meter that displays the stereo audio levels for the currently selected port (displayed by LCD).  
Automatic video quality adjustment, with additional manual control, assures maximum video quality at lengths of up to 600  
feet.  
.
All connections between local sources and remote displays can be made using CAT5, CAT5e, or CAT6 UTP cable.  
Ethernet connection speed is 10/100baseT  
A monitor can only be connected to one audio/video source at a time.  
Supported Web Browsers:  
Most modern web browsers should be supported. The following browsers have been tested:  
Microsoft Internet Explorer 6.0 or higher  
Netscape 7.0 or higher  
Mozilla FireFox 0.9.2 or higher  
Set your browser to always check if there is a newer version of the page than the version stored in cache. This  
action will ensure that it will display the most up-to-date information.  
Materials  
Materials Supplied with this kit:  
NTI SM-nXm-C5AV LCD Audio/Video Matrix switch via CAT5  
IEC Line cord, country specific  
CD with pdf file of this owners manual  
Materials Not Supplied, but REQUIRED:  
¾
XTENDEX Local and Remote Units with either CAT5 Unshielded Twisted Pair (UTP) cable, CAT5e cable, or CAT6 cable.  
Cable(s) must be terminated with appropriate RJ45 connectors wired straight thru- pin 1 to pin 1, etc. (see pg. 25 for proper  
EIA/TIA 568 B wiring method)  
¾
A null modem cable will be required for RS232 connection to a remote terminal. Specifications for this cable can be found on  
page 25.  
Cables can be purchased from Network Technologies Inc by calling 800-RGB-TECH (800-742-8324) or (330)-562-7070 or visit  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Default User Name and Passwords  
The default Telnet password is admin (lower case letters only) . For instruction on using Telnet, see page  
16.  
The default Web Interface user name is Administrator (upper case letter for "A" only).  
The default Web Interface password is admin (lower case letters only). For instruction on using the Web  
Interface, see page 17.  
FEATURES AND FUNCTIONS  
VEEMUX Features and Functions  
1. Keypad- for manual user control of connections and switch programming  
2. LCD- for visual indication of connections and audio level indication  
3. Power ON/OFF switch  
4. IEC Power Connector- for attachment of power cord  
5. Fuseholder- for replaceable 2A 250V overcurrent protection fuse (fuses mounted inside case on some models)  
6. RS232- 9 pin DIN male- for connecting a serial cable for a user terminal  
7. Ethernet- RJ45 female- for connecting the VEEMUX to a network.  
8. AV OUT- RJ45 female- for connection of CAT5 cables from CAT5 Extender Remote Units  
9. AV IN- RJ45 female- for connection of CAT5 cables from CAT5 Extender Local Units  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
XTENDEX Features and Functions  
1. Green LED- communication indicator- blinks when there is valid communication between the local and remote units.  
2. Yellow LED- power indicator- illuminates when power has been supplied to the unit  
3. Cat 5- RJ45 female- for connecting the CAT 5 cable  
4. Video Connector- 15HD female- for connecting the local user's monitor  
5. Audio Jack- 3.5mm stereo audio jack- for connecting to local speakers  
11  
6. Video Connector- blue 15HD male- for connecting to the video port on the CPU or KVM switch  
9 VDC  
AC  
ADAPTER  
7. Audio Plug- 3.5mm stereo audio plug- for connecting to CPU audio line out  
8. Audio Jack- 3.5mm stereo audio jack- for connecting to remote speakers  
9. 9VDC- 1.0A- connection jack for the AC adapter  
10. Video Connector- 15HD female- for connecting the remote user's monitor  
11. AC Adapter- to power the Remote and Local Units (1 for each required)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
XTENDEX INSTALLATION  
(XTENDEX not included)  
Audio Compatibility  
The audio input of the ST-C5VA-600 Audio/Video Extender is compatible with the following standard CPU audio outputs:  
Line out - typically lime green in color  
Speaker out- typically orange in color  
Headphone out- typically located on the CD-ROM (audio extension cable would be needed)  
The audio output of the ST-C5VA-600 Audio/Video Extender is compatible with self-powered stereo speakers.  
The Local Unit  
1. Plug the cables of the Local Unit into the back of the CPU. (See Fig. 1.)  
a) Connect the blue 15HD cable end to the VGA port on the back of the CPU.  
b) Connect the black 3.5mm stereo plug into the "line out", "spkr", or "headphones" jack on the  
back of the CPU or other audio/video source (i.e. VCR, DVD player, etc.).  
Notes:  
If all 3 jacks are available, use the jack marked "line out".  
The "line out" jack is typically lime green and may be marked with this symbol  
The "spkr" jack is typically orange, and may be marked with this symbol  
The "headphones" jack may be marked with this symbol  
Figure 1- Connect the Local Unit to the CPU  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
2. Make connections for a Local User (see Fig. 2)  
a) Connect the cable from the local user's VGA monitor to the female 15HD port on the Local Unit.  
b) Connect the cable from the local speakers into the 3.5mm jack on the local unit.  
Figure 2- Connect Local User Components to Local Unit  
3. Connect the CAT5 cable to the “Cat 5” port on the Local Unit. (See Fig. 2.) When properly inserted  
the cable end should snap into place.  
Note: If an RJ45 wall outlet is being used, connect the other end of the extension cable to the  
RJ45 wall outlet.  
!
WARNING: Never connect the ST-C5VA-600 Extender to an Ethernet card, Ethernet router, hub or switch or  
other Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may result.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
The Remote Unit  
1. Position the Remote Unit such that the CAT5 cable, the monitor cable, speaker cable, and the AC  
adapter power connector can each reach the Remote Unit comfortably.  
2. Connect the monitor cable to the female 15HD video connector on the Remote Unit.  
3. Connect the speakers to the 3.5mm jack on the Remote Unit (see Fig. 3).  
Figure 3- Connect the Extended Components to the Remote Unit  
4. Connect the CAT5 cable to the “Cat 5” port on the Remote Unit. (See Fig. 3.) When properly inserted the CAT5 cable end  
should snap into place.  
Note: If an RJ45 wall outlet is being used, connect the other end of the extension cable to the RJ45  
wall outlet.  
!
WARNING: Never connect the ST-C5VA-600 Extender to an Ethernet card, Ethernet router, hub or switch or  
other Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may result.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Plug-in and Boot Up  
1. Plug the power cord from the monitor into the power outlet.  
2. Connect each AC adapter power connector to the 9VDC ports on the Remote and Local Units. Make sure the power  
connectors go into each port all the way. Plug each AC adapter into a power outlet. The yellow LED on the RJ45  
connector of both the Remote and Local Units should illuminate, indicating that a proper power connection has been made to  
them. (See Fig. 4.)  
Figure 4- Connect the AC adapters  
Note: The green LED on each RJ45 connector will blink anytime data traffic is passing between the Local and  
Remote Units, indicating proper CAT5 cable connection and communication. (See Fig. 4)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
VEEMUX INSTALLATION  
1. Connect an ST-C5VA-600 Local Unit to an audio/video source as described on pages 4-5.  
2. Connect a CAT5 cable (wired as specified on page 26) between the ST-C5VA-600 Local Unit and VEEMUX connector  
"AV IN 1".  
Figure 5- Attach ST-C5VA-600 Local Unit to VEEMUX  
3. Connect a CAT5 cable (wired as specified on page 26) between an ST-C5VA-600 Remote Unit and VEEMUX connector  
"AV OUT 1".  
Note: Shielded CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission  
requirements.  
4. Connect a monitor and stereo speakers to the ST-C5VA-600 Remote Unit as described on page 6.  
5. Connect the powercord as shown in Fig. 6.  
Figure 6- Attach ST-C5VA-600 Remote Unit to VEEMUX  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Note: This total length of CAT5 cable between the ST-C5VA-600 Remote and Local units cannot exceed 600 feet. (See  
Fig. 9)  
Figure 7- Maximum total CAT5 cable length cannot exceed 600 feet  
6. To use the WEB Interface (page 15) , connect a CAT5 cable between the Local Network and the RJ45 connector on the  
VEEMUX labeled ETHERNET. (See Fig. 8) This cable should be wired straight through between two RJ45 connectors (pin 1  
to pin 1, etc.)  
Figure 8- Connect VEEMUX to LAN  
7. For direct connection of a user terminal, connect a null modem cable (specifications on page 25) between the user terminal  
and the 9 pin DIN male connector on the VEEMUX labeled RS232. (See Fig. 9) The user terminal will control the VEEMUX via  
the RS232 interface (page 13).  
Figure 9- Connect user terminal to VEEMUX  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
USING THE VEEMUX SWITCH  
The VEEMUX can be controlled by either of four methods:  
Using the keypad of the front panel interface  
Directly via an RS232 interface  
Remotely via web interface  
Remotely via telnet interface  
Front Panel Interface Overview  
On the front panel is an 18 push-button keypad and LCD that enable the user to operate the switch and change settings.(See Fig.  
10)  
IN:  
OUT:  
IN:  
1
1
5
5
2
2
6
6
3
3
7
7
4
4
8
8
6
1
7
2
8
3
0
5
Esc  
9
4
Out  
In  
*
OUT:  
Enter  
Menu  
Figure 10- Front panel Interface LCD and keypad  
After turning power ON, the LCD will show a start-up message for three seconds (see Fig. 11).  
Figure 11- VEEMUX start-up message on LCD  
During this time, the VEEMUX retrieves its switch settings from memory (the startup configuration is retrieved from stored  
configuration 0). Pressing any buttons during this time will have no effect. After 3 seconds, the switch will function normally and  
display the current configuration of connections. By default, the display will show all connections between Inputs and Outputs,  
displaying 8 at a time from the first to the last. Each set of 8 connections will display for 2 seconds, and the cycle will repeat  
indefinitely every 4 seconds.  
Figure 12- Connections screen on LCD, displays 8 sets at a time  
Download from Www.Somanuals.com.1A0ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Keypad Control  
The front panel interface keypad and LCD enable the user to monitor switch status and route any user to any audio/video  
source (INPUT) on the switch. Along with the routing of the INPUTS to the user devices (OUTPUTS) the keypad and LCD allow  
the users to configure the RS-232 control interface and web server settings. The keypad buttons perform the following functions:  
Key  
ESC  
0 – 9  
In  
Action  
Cancel current action.  
Used to enter numbers. ( n )  
The INPUT number can be entered (2 digits or 1 digit and ENTER) followed by the desired  
OUTPUT to be connected to (2 digits or 1 digit and ENTER).  
Out  
The OUTPUT number can be entered (2 digits or 1 digit and ENTER) followed by the  
desired INPUT to be connected to (2 digits or 1 digit and ENTER).  
ENTER  
Used to enter commands or values.  
Used to scroll menu up  
Used to scroll menu down  
MENU  
The Configuration Menu is displayed.  
Activate Memory Function- 10 memory locations (0 – 9), 0 is the power ON default.  
- to Save current connections  
- to Recall connections * - Out - n (0-9) - ENTER  
Also used to enter the periods in a IP address or Subnet Mask  
* - In - n (0-9) - ENTER  
*
Configuration Menu  
By pressing the Menu key the display will show the following configuration menu:  
Figure 13- Configuration menu on LCD  
The configuration menu includes the following items:  
1. Set Serial Address – allows the user to change the serial address of the switch  
2. Set Serial Speed – allows the user to change the baud rate  
3. Set IP address – allows the user to change the IP address allocated to the switch  
4. Set Subnet Mask – allows the user to change the subnet mask  
5. Set Default Gateway- allows the user to change the default gateway used  
6. Set Wserver Timeout- allows the user to change the web server access timeout period  
7. Adjust Contrast – allows the user to change the contrast of LCD  
8. Video Adjustment – allows the user to force a video quality adjustment  
9. Show Size – allows the user to see the dimensions of the switch and status of the webserver  
Only 4 items are visible at a time. To navigate through configuration menu items, the user will use the  
and button from  
keypad. The current item is highlighted. The user can select the current item by pressing the ENTER button. Alternatively, the  
user can directly select any item, by pressing the corresponding number (1 to 9) from the keypad.  
Download from Www.Somanuals.com.1A1ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Set Serial Address  
When selecting this menu item, the display shows the current serial address and the user is prompted to introduce a new  
serial address. One or two digits can be entered followed by <Enter>. The display will prompt if the address is successfully  
changed. Pressing <Esc> will cancel this command. The serial address is used by the RS232 line to send commands. Valid  
addresses are between 1 and 99. The factory default address is 1.  
Figure 14- Set Serial Address from LCD and keypad  
Set Serial Speed  
When selecting this menu item, the display shows the current serial speed (baud rate) and offers options to change to a  
different speed:  
Figure 15- Set baud rate from LCD and keypad  
The current option is highlighted. Move the highlight (by using arrow keys) to the desired speed and press <Enter> to apply. An  
alternative way is to press the number key that corresponds to desired speed (see Fig. 15).  
To exit from this submenu, press <Esc>.  
Available speeds are: 1200,2400,4800, and 9600 baud.  
Factory default speed is 9600 baud.  
Set IP Address  
When selecting this menu item, the display shows the current IP address (default factory IP address is 192.168.1.1) and  
prompts the user to enter a new IP address. A new IP address is entered using number keys and the <*> key for periods. The  
user must press <Enter> to save the new IP address. If the new address is invalid, the user will be prompted, otherwise the  
display will indicate that the address was successfully changed.  
Figure 16- Set IP Address from LCD and keypad  
Set Subnet Mask  
When selecting this menu item, the display will show the current subnet mask. A new subnet mask is entered using  
number keys and the <*> key for periods. The user must press <Enter> to save the new subnet mask. If the new subnet mask is  
invalid, the user will be prompted, otherwise the display will indicate that the subnet mask was successfully changed.  
The default subnet mask is 255.255.255.0. This does not need to be changed for VEEMUX to work. If deemed  
necessary, the network administrator will change it .  
Set Default Gateway  
When selecting this menu item, the display will show the current default gateway. A new default gateway mask is  
entered using number keys and the <*> key for periods. The user must press <Enter> to save the new default gateway. If the new  
default gateway is invalid, the user will be prompted, otherwise the display will indicate that the default gateway mask was  
successfully changed.  
The factory set default gateway is 192.168.1.0. This does not need to be changed for VEEMUX to work. If deemed  
necessary, the network administrator will change it .  
Download from Www.Somanuals.com.1A2ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Set Wserver Timeout  
When selecting this menu item, the display shows the current webserver timeout period and offers optional values to  
change it to.  
Figure 17- Wserver Timeout Period  
The currently selected value is highlighted. Move the highlight (using the arrow keys) to the desired timeout value and press  
<Enter> to apply the value. An alternative method of selection is to press the number key that corresponds to the desired timeout  
value.  
Available timeout period values include: 1,5,10,15, or 30 minutes, and 1,2,5, or 8 hours. The default timeout period is 1 hour.  
To exit, press <Esc>.  
Adjust Contrast  
When selecting this menu item, the display shows a scroll bar with the current position of the LCD display contrast value.  
The user can change the contrast value using an arrow key from the Keypad. Pressing the up arrow will increase contrast while  
pressing down arrow will decrease it. The scroll bar will move according to the contrast value and the effects of contrast  
adjustments will be immediately visible on the LCD display.  
Figure 18- Adjust LCD contrast  
After adjusting the contrast the user can press <Enter> to store the new contrast value, or press <Esc> to return the contrast to  
its original value.  
Video Adjustment  
This allows the user to force a connection to an output and initiate the video quality adjustment to assure the image on  
the monitor is as clear as possible. This is useful when a CAT5 cable is changed without first switching the connection in the  
VEEMUX. Otherwise an automatic video quality adjustment is made whenever a new connection (Input to Output) is established  
and whenever VEEMUX is powered ON.  
Show Size  
This menu item allows the users to see the number of inputs and outputs available for the switch and the status of the  
webserver.  
Displaying Audio Level (Digital VU-Meter)  
To display the dynamic audio level (volume) of one of the outputs, the user should press <Esc> from the normal display  
mode (connection status). The following window will display the decibel level of left and right audio channels. The rightmost  
gradation on the scale corresponds to 0dB, and the leftmost -96dB.  
Figure 19- View Output audio level  
To display the audio output level of a different Output port, type the number of the desired Output (1 or 2 digits) and press  
<Enter>.  
Download from Www.Somanuals.com.1A3ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
This function is particularly useful to determine if a lack of sound from speakers is due to failed speakers, or lack of audio signal  
through the VEEMUX. If no signal is seen in this display, check all connections between the audio source, the XTENDEX, and  
the respective Input port on the VEEMUX.  
Pressing <Esc> again will return to the connections display.  
RS232 Interface  
A user may control the VEEMUX using an RS232 interface by connecting a PC to the 9 pin DIN male connector on the VEEMUX  
labeled "RS232". Using a program such as HyperTerminal or the Matrix Switcher's Control Program (page 15), the VEEMUX  
can be setup and controlled.  
When using HyperTerminal (or a similar program), configured at the same baud rate as in the VEEMUX (default is 9,600), 8 bits,  
no parity, no flow control, the VEEMUX can be controlled by sending the commands in the following chart, where:  
SW = the Switch Serial Address  
<CR> = the Carriage Return character  
IP = the input port  
OP = the output port  
ip = the IP address  
Command  
Answer  
Description  
CS SW,IP,OP  
*<CR>  
Connect One Input (Audio/Video Source) to Output (User Port)  
CA SW,IP  
RO SW,OP  
CC SW,xx  
RC SW,xx  
CB 00,nn  
RV SW,00  
RU SW  
*<CR>  
*<CR>IP<CR>  
*<CR>xx<CR>  
*<CR>xx<CR>  
none  
Connect All Outputs To Input  
Read Connection For Output  
Save Matrix Connections Into Memory Bank xx  
xx= 00-09  
Restore Matrix Connections From Memory Bank xx  
Xx=00-09  
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)  
Factory default is 9,600  
*<CR>string\0<CR>  
*<CR>IP,OP<CR>  
Read NTI Version String  
Read Unit Size  
Set the IP address, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field  
Leading zeroes are accepted  
Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field.  
Leading zeroes are accepted  
Set the default gateway, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field  
Leading zeroes are accepted  
Set the website timeout; timeout = numeric string of timeout in  
seconds.  
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800  
Read the IP address, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field  
Leading zeroes are accepted  
Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field  
Leading zeroes are accepted  
Read the default gateway, ip is in xxx.xxx.xxx.xxx format,  
number of digits is minimum 1 and maximum 3 for each field  
Leading zeroes are accepted  
Read the website timeout; timeout = numeric string of timeout in  
seconds.  
EA SW,ip  
EM SW,ip  
EG SW,ip  
ET SW,timeout  
RA SW *  
*<CR>  
*<CR>  
*<CR>  
*<CR>  
<CR>ip<CR>  
<CR>ip<CR>  
<CR>ip<CR>  
<CR>timeout<CR>  
RM SW *  
RG SW *  
RT SW *  
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800  
If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch  
memory, the command will be ignored. If the SW field corresponds to the serial address, but the syntax is wrong after this field,  
the switch will answer with ?<CR>.  
Download from Www.Somanuals.com.1A4ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Matrix Switcher's Control Program For Windows 9X, NT, 2000 and XP  
The Matrix Switcher's Control Program is an easy and powerful graphical program that controls NTI matrix switches through an  
RS232 interface from an attached PC. The Matrix Switcher's Control Program is included on the CD packaged with the  
VEEMUX. The Matrix Switcher's Control Program is downloaded by clicking on the link "Download Matrix Switcher's Control  
Program".  
To install the Matrix Switcher's Control Program after downloading  
1. Locate the Setup.exe in the directory the program was downloaded to and double-click on it  
2. Follow the instructions on the screen  
The Matrix Switcher's Control Program performs best on monitors set to a screen resolution of at least 800 X 600. Instruction for  
using the Matrix Switcher’s Control Program is available by opening "MSCP Help" in the "NTI" program group once the program  
has been installed and is open on the screen.  
To open "MSCP Help" from the Windows desktop  
1. Click on START  
2. Click on PROGRAMS  
3. Click on NTI  
4. Click on MSCP Help  
Download from Www.Somanuals.com.1A5ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Telnet Interface  
The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server  
listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:  
telnet 192.168.1.1 2000  
The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.  
The default factory password is "admin".  
With a proper password sent the VEEMUX will respond with:  
Password Successful  
Connection Established  
The following commands are now available:  
Command  
Reply  
Description  
Help  
H(elp) or  
h(elp)  
Displays the list of  
commands  
<Ctrl>-<X>  
Good Bye.  
Quit telnet session  
(see note 4 below) Connection to host lost.  
CS nn,mm  
CA nn  
RO nn  
CC nn  
RC nn  
CB nn  
RV 00  
RU  
*<CR>  
*<CR>  
Connect one Output Port (nn) To one Input Port (mm)  
Connect All Outputs To Input  
Read Connection For Output.  
Returns the number of the input (mm) connected to output nn  
Save Matrix Connections Into Memory Bank nn  
nn should be between 00 and 09  
Restore Matrix Connections From Memory Bank nn  
nn should be between 00 and 09  
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)  
Factory default is 9,600.  
*<CR>mm<CR>  
*<CR>nn<CR>  
*<CR>nn<CR>  
*<CR>  
*<CR>string\0<CR>  
*<CR>nn,mm<CR>  
Read NTI Version String  
Read Unit Size  
Returns the number of inputs(nn) and the number of outputs (mm)  
User is prompted to  
introduce the password  
twice  
CP  
Change password  
Notes:  
1. The commands must be typed exactly as shown in the chart. The commands are case sensitive.  
2. If a mistake is made, the user must backspace to the beginning and completely retype the command.  
3. If a command is sent that the VEEMUX does not recognize or exceeds the configuration of the switch, the reply  
"?" may be received. Check the command syntax and try again.  
4. To quit the telnet session, press the keyboard keys <Ctrl><X> .  
Download from Www.Somanuals.com.1A6ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Web Interface  
A user may control the connections of the VEEMUX using a Web Interface via any web browser (see page 1 for web supported  
browsers). With the VEEMUX connected to a LAN through an Ethernet cable, a user can access the web interface controls inside  
the VEEMUX.  
FYI: To quickly locate a VEEMUX on the LAN and edit the IP address settings, use the Device Discovery Tool (page 25).  
To access the web interface, type the current IP address into the address bar of the web browser.  
Address  
To open a SSL-encrypted connection, type:  
Address  
You will be prompted to accept a certificate. Accept the NTI certificate.  
A "Welcome Page" will appear.  
Figure 20- Web interface Welcome page  
Enter the Password  
Click on a link to the left to be prompted for a username and password.  
Default User Name = Administrator  
(upper case letter for "A" only)  
Default Password = admin (lower  
case letters only)  
Note: The browser must be configured to accept  
cookies in order for the user to successfully make use of  
the web interface.  
Figure 21- Web interface Login Prompt  
As described on page 18, each link will enable different areas of control for the VEEMUX.  
Download from Www.Somanuals.com.1A7ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Switch Page  
Figure 22- Web interface Switch page  
The Switch page (above) displays the active connections (shown in orange) and enables the user to control the  
connections of the VEEMUX. Up to 10 different connection configurations can be saved and later recalled by any  
connection method.  
Note: Configuration 0 will be automatically loaded when the VEEMUX is powered up.  
To change a connection, click on the radio button (square image with circle in the center) that intersects the input  
and output columns. A black dot will be placed in the circle to indicate the selection. Then press the Submit  
button. The display will be reloaded with the selections changed to orange to indicate they are now active. Multiple  
connections can be changed simultaneously.  
To quickly clear the selected radio buttons press the Clear Changes button. This will only work if the Submit  
button has not already been pressed with the selections made.  
To quickly connect all outputs to a single input, choose the desired input from the "Set all Outputs to Input" drop-  
down list and press the Submit button.  
Note: If radio buttons are selected in addition to using the "Set all Outputs to Input" option, the selections  
made by the "Set all Outputs to Input" will take precedence when the Submit button is pressed. Selections  
that conflict with it will be ignored.  
Download from Www.Somanuals.com.1A8ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
To save a configuraton, from the Stored Configurations user interface, use the drop-down list to select the  
desired slot (numbers 0-9) to save the active configuration into and press the Save button.  
Note: This will save the currently active configuration on  
the VEEMUX. If changes have been made in the web  
interface without first pressing the Submit button, those  
changes will not yet be part of the active configuration.  
Note: If changes to the active configuration have been  
made by another user prior to saving the  
current connection selections, the changes made by the  
other user will be saved as the configuration.  
The webpage configuration that loads after a Save is the configuration that was actually saved.  
To load a saved configuration, from the Stored Configurations user interface, use the drop-down list to select the  
desired configuration. Then press the Load button. The VEEMUX will make the connections and the screen will  
refresh to show the connections associated with that configuration selection.  
To adjust video quality, from the Video Adjustment user interface, press the Optimize button. This will force the  
VEEMUX to adjust video signal levels to achieve maximum video quality on all connected monitors.  
Download from Www.Somanuals.com.1A9ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Setup Pages  
These settings enable the user to configure the VEEMUX web interface connection.  
This change will take a few seconds and automatically redirect the user to the IP  
address specified.  
Note: Since the webserver will be restarting all active connections will be logged out.  
The Website Timeout option controls how long an inactive web connection will stay logged in. Any change to the  
Website Timeout configuration takes effect immediately.  
Figure 23- Web interface Setup page  
Figure 24- Web interface Serial Setup page  
The Serial Address and Serial Speed (Fig. 24) do not require a reset and will take effect immediately.  
Download from Www.Somanuals.com.2A0ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Video Input Names  
The Video Input Names page enables the Administrator to change  
the name of the input ports displayed on the Switch page. To  
change a Video Input Name, enter the name of the input port for  
the desired port number, and press Save.  
Note: Only the changes to the input port directly to the left of  
the Save button will be saved. All other changes to input ports  
without pressing the port's respective Save button will be  
discarded. All input port names must be no more than 12  
characters in length and only alphanumeric characters may be  
used.  
Figure 25- Web interface Video Input Names page  
Video Output Names  
From the Administration menu, the Video Output  
Names page can be displayed. This page enables the  
Administrator to change the names of the output ports  
displayed on the Switch page. To change a Video  
Output Name, enter the name of the port for the desired  
output port number, and press "Save".  
Figure 26- Web interface Video Output Names page  
Download from Www.Somanuals.com.2A1ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Update Firmware  
Figure 27- Web interface Update Firmware page  
The Update Firmware page shows the current version of the firmware and enables the Administrator to update the  
firmware of the VEEMUX.  
WARNING: Failure to carefully follow these directions can permanently damage the VEEMUX. Please read these  
directions in full before continuing. Do not, under any circumstances, reset or power-down the VEEMUX while the  
firmware is being updated. Do not attempt to update the firmware if a power-failure is likely.  
Note: The Firmware can only be updated from the non-secure (http) website. If you attempt to access this page from the  
secure (https) website, you will be automatically redirected to the non-secure site.  
To update the firmware:  
1. Contact NTI for the latest firmware file and copy it to your computer.  
2. On the Update Firmware page, browse to the firmware file.  
3. Press Update Firmware.  
4. Wait for the following message to appear (may take several minutes):  
Upload Succeeded  
Flash of new image completed:  
The system will automatically restart.  
5. The VEEMUX will restart itself in 10 seconds, logging out all connections. After approximately 40 seconds,  
the VEEMUX will be ready to resume operation.  
If a message appears stating that the Upload has failed, or that a non-fatal error has occurred:  
1. Ensure that the file being uploaded is the NTI firmware file.  
2. Repeat the process from step 2 above.  
Note: This message does not indicate that damage to the product has occurred.  
If a message appears stating that there has been a fatal error:  
1. DO NOT RESET OR POWER-DOWN THE VEEMUX.  
2. Repeat the update process from the first step 2 above.  
3. If you get another Fatal Error message, call NTI tech-support at 1-800-742-8324 or 330-562-7070.  
FYI: The VEEMUX should continue to run normally unless it is reset. However, damage may have occurred to  
the web server firmware that will prevent the product from starting up correctly.  
Download from Www.Somanuals.com.2A2ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Change Password Page  
Figure 28- Web interface Password page  
Use this page to change the password for accessing the web interface. (This password is also used for the telnet  
interface.) Be sure to make note of the new password exactly as it is case sensitive. The password must be  
between 5 and 16 characters in length and can be alphabetical or numeric.  
Help Page  
This page explains the purpose of each of the other pages in the VEEMUX web interface.  
Update Web Server  
Click on this selection to globally update the Web Server to any settings that have been changed though Telnet, the  
RS232 interface, or via the front panel of the VEEMUX. All users presently connected will be disconnected and  
must log back in after using this command.  
Figure 29- Updating the Web Server  
Download from Www.Somanuals.com.2A3ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Logout Page  
Figure 30- Web interface Logout page  
This page will enable the user to end the session and close the web interface connection. Click on the "Press Here  
to Continue Logout" button to exit the VEEMUX web interface.  
Note: The connection will timeout automatically after a preset period of inactivity, configurable on the Web Setup  
page.  
Download from Www.Somanuals.com.2A4ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
DEVICE DISCOVERY TOOL  
In order to easily locate the VEEMUX on a network, or change network settings, the NTI Device Discovery Tool may be used.  
A
link to the Discovery Tool is provided on the web page that appears when you insert the instruction manual CD into your CD ROM  
drive. Click on the link or browse the CD and click on the file discover.html . This will open your browser and display the Device  
Discovery Tool page.  
Note: The Discovery Tool requires the Java Runtime Environment to operate. A link to the web page from which it can  
be downloaded and installed is provided on the CD.  
Note: The computer using the Discovery Tool and the VEEMUX must be connected to the same physical network in order  
for the Device Discovery Tool to work.  
Figure 31- Device Discovery Tool page  
Use the Device Discovery Tool to display all NTI VEEMUX devices on your network, along with their network settings. Follow  
the instructions on the Device Discovery Tool page to use the tool and to change the device settings if so desired.  
Download from Www.Somanuals.com.2A5ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
INTERCONNECTION CABLE WIRING METHOD  
CAT5 Cable  
The connection cable between the VEEMUX and XTENDEX remote and local units is terminated with RJ45 connectors and must  
be wired according to the EIA/TIA 568 B industry standard. Wiring is as per the table and Fig. 32 below.  
Pair 3  
Pair 2  
Pin Wire Color  
Pair  
2
Function  
Pair 4  
T R  
Pair 1  
1
2
3
4
5
6
7
8
White/Orange  
Orange  
White/Green  
Blue  
White/Blue  
Green  
White/Brown  
Brown  
T
R
T
R
T
R
T
R
2
3
1
1
3
4
4
T
R T  
R
T R  
1
+
2 3  
-
4
-
7 8  
+ -  
5
+
6
-
+
Figure 32- View looking into RJ45 female  
Null Modem Cables  
Pinout of RS232 port on VEEMUX  
The VEEMUX RS232 serial port is a DB-9M (male) connector configured as a DTE (data terminal equipment) port (like the 9 pin  
serial port on a CPU). The RS232 port interface signals are listed below, including equivalent CCITT V.24 identification, and signal  
direction:  
DB-9M  
pin #  
Common  
name  
DCD  
RxD  
EIA  
name  
CF  
BB  
BA  
CD  
AB  
CC  
CA  
CB  
CE  
CCITT  
name  
109  
104  
103  
108.2  
102  
107  
105  
106  
Function  
Direction  
1
2
3
4
5
6
7
8
9
Not used  
--  
Receive Data  
Transmit Data  
Not used  
Signal Ground  
Not used  
Request To Send  
Clear To Send  
Not used  
Input  
Output  
--  
--  
Output  
Input  
--  
TxD  
DTR  
SG  
DSR  
RTS  
CTS  
RI  
125  
Pinouts for typical DTE to DTE null modem cable for CPU connection  
VEEMUX (DTE) to 9 PIN DTE (PS2 or SUN)  
VEEMUX (DTE) to 25 PIN DTE (MAC)  
VEEMUX  
9 pin  
PS/2 or SUN CPU  
VEEMUX  
MAC CPU  
25 pin  
Direction Pin # Function  
Signal  
9 pin  
Function  
TxD  
9 pin  
Function  
Signal  
Function  
Pin #  
Direction Pin #  
Pin #  
RxD  
TxD  
CTS  
RTS  
SG  
2
3
8
7
5
3
2
7
8
5
RxD  
TxD  
CTS  
RTS  
SG  
2
3
8
7
5
2
3
4
5
7
TxD  
RxD  
RTS  
CTS  
SG  
RxD  
RTS  
CTS  
SG  
9 PIN  
DTE  
9 PIN  
DTE  
9 PIN  
DTE  
VEEMUX  
MAC CPU  
PS/2 or SUN CPU  
VEEMUX  
25 PIN DTE  
Download from Www.Somanuals.com.2A6ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
1
3
4
5
6
8
9
10  
13  
11 12  
2
7
4
1
2
3
5
6
8
18  
19 20  
9
14 15  
17  
16  
7
21 22 23 24 25  
Mating Face  
of a 9D Male  
Mating Face of DB25 Male  
TROUBLSHOOTING  
No audio  
PROBLEM:  
SOLUTION:  
Check all connections and power to all devices. Use the VU-Meter to determine if audio is passing through  
the VEEMUX  
PROBLEM:  
SOLUTION:  
Video not crisp & clear  
Force video quality adjustment (see page 13)  
PROBLEM:  
SOLUTION:  
No Video  
Check cable connections, power to all devices, and CAT5 cable wiring (if cables were terminated by the  
customer)  
PROBLEM:  
SOLUTION  
Telnet or webserver not working  
Check indicator LEDs on the back of the unit.  
Is there a valid connection? If not, check all cable connections.  
Does the data light illuminate? Make sure the IP address is correct.  
Ensure local network connection supports and is configured for 10baseT.  
PROBLEM:  
SOLUTION:  
RS232 control not working  
Wrong serial address. Verify the address of the unit that will not communicate. Check all cable connections.  
APPENDIX  
Appendix A- Default Settings  
SETTING  
Login Username  
Login Password  
Serial Speed  
DEFAULT VALUE  
Administrator (case sensitive)  
admin (case sensitive)  
9,600 bps  
Serial Address  
IP Address  
01  
192.168.1.1  
Subnet Mask  
255.255.255.0  
Appendix B- General Information  
DESCRIPTION  
SPECIFICATION  
Interconnect Cable  
CAT 5/5e/6 Solid UTP EIA/TIA 568B wiring w/  
male RJ45 connectors  
"RS232" Connector  
"ETHERNET" Connector  
"AV IN" and "AV OUT"  
Connectors  
9D male  
RJ45 female  
RJ45 female  
Operating temperature  
Video quality adjustment  
Replaceable fuse rating  
Power requirements  
+10°C to +40°C  
Automatic (up to 600 feet)  
2A 250V  
110 or 220VAC, 50 or 60Hz, 1A  
Download from Www.Somanuals.com.2A7ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Appendix C- Distances and Resolutions for CAT5/CAT5e and CAT6 Cables  
CABLE  
DISTANCE (feet)  
RESOLUTION  
CAT5/CAT5e (UTP)  
CAT5/CAT5e (UTP)  
CAT5/CAT5e (UTP)  
CAT5/CAT5e (UTP)  
CAT6 (UTP)  
600  
400  
300  
100  
300  
200  
100  
1024x768 at 60Hz  
1280x1024 at 60Hz  
1600x1200 at 60Hz  
1920x1440 at 60Hz  
1024x768 at 60Hz  
1280x1024 at 60Hz  
1920x1440 at 60Hz  
CAT6 (UTP)  
CAT6 (UTP)  
Appendix D- Product Dimensions  
CONFIGURATION  
SIZE (In.) WxDxH  
SM-8X8-C5VA-LCD  
SM-8X16-C5VA-LCD  
SM-16X8-C5VA-LCD  
SM-16X16-C5VA-LCD  
SM-32X8-C5VA-LCD  
SM-32X16-C5VA-LCD  
19x12x1.75  
19x12x1.75  
19x12x1.75  
19x12x3.5  
19x12x3.5  
19x12x3.5  
Appendix E- Rack mounting Instructions  
This NTI switch was designed to be directly mounted to a rack and includes a mounting flange to make attachment easy.  
Install 4 captive nuts to the rack in locations that line up with the holes (or slots) in the mounting flange on the NTI switch.  
Then secure the NTI switch to the rack using four 3/16" diameter screws (not provided). Each screw should be of sufficient  
length to go completely through the NTI mounting flange, rack frame and fully engage all threads in the captive nut. Be sure to  
tighten all mounting screws securely.  
Do not block power supply vents in the NTI switch chassis (if provided) . Be sure to enable adequate airflow in front of and  
behind the NTI switch.  
Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.  
Rack  
Captive  
Nuts  
R
NETWORK  
TECHNOLOGIES  
INCORPORATED  
1275 Danner Drive Tel: 330-562-7070  
Fax: 330-562-1999  
Aurora Ohio 44212  
NTI  
3/16” Diameter  
Screws  
Figure 33- Mount Switch to a Rack  
Download from Www.Somanuals.com.2A8ll Manuals Search And Download.  
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5  
Grounding  
These products have protective earth ground terminals and are built with full attention to consumer safety. There must be an un-  
interruptible safety earth ground between the main power source and the product's power cord or supplied power cord set.  
If ever the possibility exists for the grounding protection to have been reduced in any way, disconnect the power supply until the  
grounding connection has been fully restored.  
Servicing  
NTI products are not intended to be serviced in the field and contain no user-serviceable parts. In the event repair is needed, all  
servicing must be performed by factory trained and authorized service personnel. Only those items specifically identified in this  
manual (if any) may be adjusted by the user of this product and adjusted only as instructed in this manual.  
WARRANTY INFORMATION  
The warranty period on this product (parts and labor) is one (1) year from the date of purchase. Please contact Network  
Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com  
for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.  
Man050  
Rev 4/10/06  
Download from Www.Somanuals.com.2A9ll Manuals Search And Download.  

Multiquip Music Mixer WM 700P User Manual
Multiquip Portable Generator CDA45SSIU3 User Manual
NEC Projector VT695 700 User Manual
Nortel Networks Telephone Accessories NN43110 100 User Manual
NuTone Patio Heater 9297T User Manual
Omega Engineering Thermometer OS PP User Manual
Orion Car Audio Car Stereo System RGC2 User Manual
Panasonic Air Conditioner CS PC30JKF User Manual
Panasonic Air Conditioner CW0 C121MU User Manual
Panasonic Air Conditioner CW A120VR User Manual