Network Instruments Power Supply SFMFF4040 100 User Manual

User’s Guide  
SFMFF4040-100  
Optical Line Converter for  
Small Form Factor Pluggable (SFP)  
Transceiver Modules  
The Transition Networks SFMFF4040-100 optical line  
converter is designed to accommodate two (2) small  
form factor pluggable (SFP) transceiver modules.  
The following SFP transceiver modules are compatible with the SFMFF4040-100 converter  
and are available from Transition Networks (sold separately).  
Port 1  
empty  
Port 2  
empty  
SFMFF4040-100  
Part Number  
TN-SFP-SX  
Description  
LC, 1000Base-SX, 850 nm multimode, 220-500 mm (720-1640 ft)  
LC, 1000Base-LX, 1310 nm single mode, 10 km (6.2 miles), DMI  
LC, 1000Base-LX, 1310 nm single mode, 30 km (18.8 miles), DMI  
LC, 1000Base-LX, 1550 nm single mode, 50 km (31.2 miles), DMI  
LC, 1000Base-LX, 1550 nm single mode, 80 km (50.0 miles), DMI  
TN-SFP-LX1  
TN-SFP-LX3  
TN-SFP-LX5  
TN-SFP-LX8  
TN-SFP-LX12  
LC, 1000Base-LX, 1550 nm single mode, 120 km (74.56 miles)  
DMI  
TN-SFP-OC3M  
TN-SFP-OC3S  
TN-SFP-OC12M  
TN-SFP-OC12S  
TN-SFP-FC2XM  
LC, 100Base-FX/OC-3 SFP 1300 nm multimode 2km (1.2 miles),  
DMI  
LC, 100Base-FX/OC-3 SFP 1310 nm single mode 20km (12.4miles),  
DMI  
LC, OC-12/STM-4 SFP 1300 nm multimode 1 km (0.6 miles),  
DMI  
LC, OC-12/STM-4 SFP 1310 nm single mode 20 km (12.4 miles),  
DMI  
LC, 2x/1x/OC-48/STM-16/1000Base-SX, 850 nm multimode, DMI,  
150 m (492 ft)* on 62.5/125 µm fiber,  
300 m (984ft)* on 50/125 µm fiber  
TN-SFP-FC2XS2  
TN-SFP-FC2XS15  
TN-SFP-FC2XS40  
LC, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 2  
km (1.2 miles), DMI  
C, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 15  
km (9.3 miles), DMI  
LC, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 40  
km (24.9 miles), DMI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SFMFF4040-100  
Operation  
Status LEDs  
Technical Specifications -- continued  
Power Supply 12VDC, 0.5 Amp (North America)  
12VDC, 0.41 Amp (Europe, Japan, Latin America)  
12VDC, 1.25 Amp (UK, Australia, New Zealand, South Africa)  
The SFMFF4040-100 optical line converter is designed to operate without user  
intervention. Use the status LEDs to view the operation of the converter in the  
network.  
Environment  
Tmra*:  
-10° to 60°C (14° to 185°F)  
-40° to 85°C (14° to 185°F)  
5 to 95%, non condensing  
0 to 10,000 feet  
Storage Temp:  
Humidity:  
Altitude:  
PWR (Power)  
On = Connection to external power.  
LK1 (Fiber Link - Port 1) On = Fiber port 1 is receiving a signal.  
Warranty  
Lifetime  
LK2 (Fiber Link - Port 2) On = Fiber port 2 is receiving a signal.  
*Manufacturer’s rated ambient temperature.  
PWR  
The information in this user’s guide is subject to change. For the most up-to-date  
information on the SFMFF4040-100 optical line converter, view the user’s guide  
LK1 LK2  
Port 1  
Port 2  
The chassis version of the media converter is CFMFF4040-100. For more  
information, see the CFMFF4040-100 user’s guide on-line at:  
Link Pass-Through  
The Link Pass-Through feature allows the media converter to monitor both  
fiber RX (receive) ports for loss of signal. In the event of an RX signal loss (1),  
the media converter will automatically disable the TX (transmit) signal (2),  
thus, “passing through” the link loss (3). The far-end device is automatically  
notified of the link loss (4), which prevents the loss of valuable data  
unknowingly transmitted over an invalid link.  
For the most up-to-date information on the TN-SFP-xxx transceiver modules, see  
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,  
Subchapter J applicable at the date of manufacture.  
WARNING: Visible and invisible laser radiation when open. Do not stare into  
beam or view directly with optical instruments. Failure to observe this warning  
could result damage to your eyes or blindness.  
media converter A  
disables the fiber TX link  
media converter B  
loses the fiber RX link  
WARNING: Use of controls, adjustments or the performance of procedures  
other than those specified herein could result in hazardous radiation exposure.  
2
3
Near-End  
Device  
Media  
Converter A  
Media  
Converter B  
Far-End  
Device  
The fiber optic transmitters on this device meet Class I Laser safety requirements  
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and  
21CFR1040.11.  
4
1
original fault  
on the fiber link  
media converter B  
disables the fiber link  
Optional Accessories  
Part Number Description  
Note: Link losses will be automatically repaired by the converters.  
SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone;  
Technical Specifications  
For use with Transition Networks model SFMFF4040-100 or equivalent.  
Output: 12.6VDC, 1.0 A  
SPS-1872-PS Optional External Power Supply; 18-72VDC Piggy-Back;  
Output: 12.6VDC, 1.0 A  
Standards  
MSA (Multi-Source Agreement) compliant SFP (Small Form  
Factor Pluggables)  
E-MCR-04  
12-Slot media converter Rack (includes universal internal power  
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)  
Dimensions  
Weight  
3.25 x 4.7 x 1.0" (83 x 121 x 25 mm)  
WMBL  
Optional Wall Mount Bracket; 4.0 in. (102 mm)  
Optional Vertical Mount Bracket; 5.0 in. (127 mm)  
Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)  
Optional DIN Rail Mount Bracket (flat); 3.3in. (84 mm)  
10 oz. (283 g) approximate  
WMBV  
WMBD  
WMBD-F  
Power  
2.0 Watts (with two (2) Transition Networks SFPs installed.)  
Consumption (Power consumption depends on the type of SFPs installed.)  
5
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SFMFF4040-100  
Troubleshooting  
Contact Us  
Technical support  
Technical support is available 24 hours a day.  
US and Canada:  
International:  
If the SFMFF4040-100 converter fails, isolate and correct the failure by  
determining the answers to the following questions and taking the indicated  
action:  
1-800-260-1312  
00-1-952-941-7600  
1.  
Is the PWR (power) LED illuminated?  
NO  
Transition now  
Chat live via the Web with Transition Networks Technical Support.  
Ensure that the power adapter is the proper type of voltage and cycle  
frequency for the outlet (See “Power Supply” on page 5.)  
Ensure the power adapter is properly installed in the converter and in  
the grounded outlet.  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
Web-based seminars  
Transition Networks provides seminars via live web-based training.  
E-Mail  
YES  
Ask a question anytime by sending an e-mail to our technical support staff.  
Proceed to step 2.  
Address  
2.  
Are both LK1 & LK2 LEDs (fiber link for ports 1 & 2) illuminated?  
Transition Networks  
6475 City West Parkway  
Minneapolis, MN 55344, U.S.A.  
NO  
Ensure both SFP transceiver modules are properly inserted in the  
converter.  
Check the fiber cables for proper connection.  
Verify that the TX and RX cables on the media converter are  
connected to the RX and TX ports, respectively, on the other device.  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
telephone:  
toll free:  
fax:  
952-941-7600  
800-526-9267  
952-941-2322  
Declaration of Conformity  
YES  
Name of Mfg:  
Transition Networks  
6475 City West Parkway, Minneapolis MN 55344 U.S.A.  
Proceed to step 3.  
Model:  
Part Number:  
Regulation:  
SFMFF4040-100 SFP Optical Line Converter  
SFMFF4040-100  
EMC Directive 89/336/EEC  
3.  
Is the LK1 LED (fiber link 1) flashing?  
NO  
Purpose: To declare that the SFMFF4040-100 to which this declaration refers is  
in conformity with the following standards.  
EN 55022:1998 Class A; EN 55024: 1998+A1+A13164:2002; FCC Part 15 subpart B;  
21CFR subpart J  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
If there is no network activity on port 1, proceed to step 4.  
If there is network activity on port 1, disconnect and reconnect the  
fiber cables to restart the initialization process.  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
June 6, 2006_____  
Stephen Anderson, Vice-President of Engineering  
Date  
YES  
Proceed to step 4.  
4
Is the LK2 LED (fiber link 2) flashing?  
NO  
If there is no network activity on port 2, contact technical support.  
If there is network activity on port 2, disconnect and reconnect the  
fiber cables to restart the initialization process.  
Contact Technical Support: US/Canada: 1-800-260-1312,  
International: 00-1-952-941-7600.  
7
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
CISPR22/EN55022 Class A + EN55024; CE Mark  
FCC regulations  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio frequency energy and, if  
not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference, in which case the user will be required to correct the  
interference at the user's own expense.  
Canadian regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus  
set out on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites  
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le  
brouillage radioélectrique édicté par le ministère des Communications du Canada.  
European regulations  
Warning This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können  
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für  
Gegenmaßnahmen verantwortlich.  
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit  
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de  
prende les measures spécifiques appropriées.  
In accordance with European Union Directive 2002/96/EC of the European  
Parliament and of the Council of 27 January 2003, Transition Networks will  
accept post usage returns of this product for proper disposal. The contact  
information for this activity can be found in the 'Contact Us' portion of this  
document.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
Trademark notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright restrictions  
© 2004 Transition Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any  
means—graphic, electronic, or mechanical—without written permission from Transition  
Networks.  
Printed in the U.S.A.  
33313.C  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NEC Server ND 91649 User Manual
Northern Industrial Tools Air Compressor 123006 User Manual
Northern Industrial Tools Grinder 157791 User Manual
Northern Industrial Tools Personal Lift 14226 User Manual
Optoma Technology Projector EP723 User Manual
Oregon Clock Radio RM382P User Manual
Palsonic CRT Television 6158 User Manual
Panasonic Camcorder AG DVX100 User Manual
Panasonic Personal Computer CT T2 User Manual
Paradyne Modem 6350 A4 User Manual