User’s Guide
SFMFF4040-100
Optical Line Converter for
Small Form Factor Pluggable (SFP)
Transceiver Modules
The Transition Networks SFMFF4040-100 optical line
converter is designed to accommodate two (2) small
form factor pluggable (SFP) transceiver modules.
The following SFP transceiver modules are compatible with the SFMFF4040-100 converter
and are available from Transition Networks (sold separately).
Port 1
empty
Port 2
empty
SFMFF4040-100
Part Number
TN-SFP-SX
Description
LC, 1000Base-SX, 850 nm multimode, 220-500 mm (720-1640 ft)
LC, 1000Base-LX, 1310 nm single mode, 10 km (6.2 miles), DMI
LC, 1000Base-LX, 1310 nm single mode, 30 km (18.8 miles), DMI
LC, 1000Base-LX, 1550 nm single mode, 50 km (31.2 miles), DMI
LC, 1000Base-LX, 1550 nm single mode, 80 km (50.0 miles), DMI
TN-SFP-LX1
TN-SFP-LX3
TN-SFP-LX5
TN-SFP-LX8
TN-SFP-LX12
LC, 1000Base-LX, 1550 nm single mode, 120 km (74.56 miles)
DMI
TN-SFP-OC3M
TN-SFP-OC3S
TN-SFP-OC12M
TN-SFP-OC12S
TN-SFP-FC2XM
LC, 100Base-FX/OC-3 SFP 1300 nm multimode 2km (1.2 miles),
DMI
LC, 100Base-FX/OC-3 SFP 1310 nm single mode 20km (12.4miles),
DMI
LC, OC-12/STM-4 SFP 1300 nm multimode 1 km (0.6 miles),
DMI
LC, OC-12/STM-4 SFP 1310 nm single mode 20 km (12.4 miles),
DMI
LC, 2x/1x/OC-48/STM-16/1000Base-SX, 850 nm multimode, DMI,
150 m (492 ft)* on 62.5/125 µm fiber,
300 m (984ft)* on 50/125 µm fiber
TN-SFP-FC2XS2
TN-SFP-FC2XS15
TN-SFP-FC2XS40
LC, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 2
km (1.2 miles), DMI
C, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 15
km (9.3 miles), DMI
LC, 2x/1x/OC-48/STM-16/1000Base-LX, 1310 nm single mode, 40
km (24.9 miles), DMI
Download from Www.Somanuals.com. All Manuals Search And Download.
SFMFF4040-100
Operation
Status LEDs
Technical Specifications -- continued
Power Supply 12VDC, 0.5 Amp (North America)
12VDC, 0.41 Amp (Europe, Japan, Latin America)
12VDC, 1.25 Amp (UK, Australia, New Zealand, South Africa)
The SFMFF4040-100 optical line converter is designed to operate without user
intervention. Use the status LEDs to view the operation of the converter in the
network.
Environment
Tmra*:
-10° to 60°C (14° to 185°F)
-40° to 85°C (14° to 185°F)
5 to 95%, non condensing
0 to 10,000 feet
Storage Temp:
Humidity:
Altitude:
PWR (Power)
On = Connection to external power.
LK1 (Fiber Link - Port 1) On = Fiber port 1 is receiving a signal.
Warranty
Lifetime
LK2 (Fiber Link - Port 2) On = Fiber port 2 is receiving a signal.
*Manufacturer’s rated ambient temperature.
PWR
The information in this user’s guide is subject to change. For the most up-to-date
information on the SFMFF4040-100 optical line converter, view the user’s guide
LK1 LK2
Port 1
Port 2
The chassis version of the media converter is CFMFF4040-100. For more
information, see the CFMFF4040-100 user’s guide on-line at:
Link Pass-Through
The Link Pass-Through feature allows the media converter to monitor both
fiber RX (receive) ports for loss of signal. In the event of an RX signal loss (1),
the media converter will automatically disable the TX (transmit) signal (2),
thus, “passing through” the link loss (3). The far-end device is automatically
notified of the link loss (4), which prevents the loss of valuable data
unknowingly transmitted over an invalid link.
For the most up-to-date information on the TN-SFP-xxx transceiver modules, see
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into
beam or view directly with optical instruments. Failure to observe this warning
could result damage to your eyes or blindness.
media converter A
disables the fiber TX link
media converter B
loses the fiber RX link
WARNING: Use of controls, adjustments or the performance of procedures
other than those specified herein could result in hazardous radiation exposure.
2
3
Near-End
Device
Media
Converter A
Media
Converter B
Far-End
Device
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.
4
1
original fault
on the fiber link
media converter B
disables the fiber link
Optional Accessories
Part Number Description
Note: Link losses will be automatically repaired by the converters.
SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone;
Technical Specifications
For use with Transition Networks model SFMFF4040-100 or equivalent.
Output: 12.6VDC, 1.0 A
SPS-1872-PS Optional External Power Supply; 18-72VDC Piggy-Back;
Output: 12.6VDC, 1.0 A
Standards
MSA (Multi-Source Agreement) compliant SFP (Small Form
Factor Pluggables)
E-MCR-04
12-Slot media converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
Dimensions
Weight
3.25 x 4.7 x 1.0" (83 x 121 x 25 mm)
WMBL
Optional Wall Mount Bracket; 4.0 in. (102 mm)
Optional Vertical Mount Bracket; 5.0 in. (127 mm)
Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)
Optional DIN Rail Mount Bracket (flat); 3.3in. (84 mm)
10 oz. (283 g) approximate
WMBV
WMBD
WMBD-F
Power
2.0 Watts (with two (2) Transition Networks SFPs installed.)
Consumption (Power consumption depends on the type of SFPs installed.)
5
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SFMFF4040-100
Troubleshooting
Contact Us
Technical support
Technical support is available 24 hours a day.
US and Canada:
International:
If the SFMFF4040-100 converter fails, isolate and correct the failure by
determining the answers to the following questions and taking the indicated
action:
1-800-260-1312
00-1-952-941-7600
1.
Is the PWR (power) LED illuminated?
NO
Transition now
Chat live via the Web with Transition Networks Technical Support.
•
•
•
Ensure that the power adapter is the proper type of voltage and cycle
frequency for the outlet (See “Power Supply” on page 5.)
Ensure the power adapter is properly installed in the converter and in
the grounded outlet.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
Web-based seminars
Transition Networks provides seminars via live web-based training.
E-Mail
YES
•
Ask a question anytime by sending an e-mail to our technical support staff.
Proceed to step 2.
Address
2.
Are both LK1 & LK2 LEDs (fiber link for ports 1 & 2) illuminated?
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
NO
•
Ensure both SFP transceiver modules are properly inserted in the
converter.
Check the fiber cables for proper connection.
Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
telephone:
toll free:
fax:
952-941-7600
800-526-9267
952-941-2322
•
•
•
Declaration of Conformity
YES
•
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
Proceed to step 3.
Model:
Part Number:
Regulation:
SFMFF4040-100 SFP Optical Line Converter
SFMFF4040-100
EMC Directive 89/336/EEC
3.
Is the LK1 LED (fiber link 1) flashing?
NO
Purpose: To declare that the SFMFF4040-100 to which this declaration refers is
in conformity with the following standards.
EN 55022:1998 Class A; EN 55024: 1998+A1+A13164:2002; FCC Part 15 subpart B;
21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
•
•
If there is no network activity on port 1, proceed to step 4.
If there is network activity on port 1, disconnect and reconnect the
fiber cables to restart the initialization process.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
•
June 6, 2006_____
Stephen Anderson, Vice-President of Engineering
Date
YES
•
Proceed to step 4.
4
Is the LK2 LED (fiber link 2) flashing?
NO
•
•
If there is no network activity on port 2, contact technical support.
If there is network activity on port 2, disconnect and reconnect the
fiber cables to restart the initialization process.
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
7
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Compliance Information
CISPR22/EN55022 Class A + EN55024; CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de
prende les measures spécifiques appropriées.
In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will
accept post usage returns of this product for proper disposal. The contact
information for this activity can be found in the 'Contact Us' portion of this
document.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright restrictions
© 2004 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means—graphic, electronic, or mechanical—without written permission from Transition
Networks.
Printed in the U.S.A.
33313.C
Download from Www.Somanuals.com. All Manuals Search And Download.
|