National Instruments Network Card NI PXI 7811R User Manual

Getting Started with the  
NI PXI-7811R  
This document explains how to set up the National Instruments PXI-7811R  
device.  
Introduction  
The PXI-7811R is an R Series reconfigurable I/O (RIO) device with  
160 digital I/O (DIO) lines.  
Traditional digital I/O devices have a fixed functionality provided by an  
application-specific integrated circuit (ASIC), but the PXI-7811R has a  
field-programmable gate array (FPGA) that allows you to define device  
functionality and timing.  
You can use the LabVIEW FPGA Module to graphically design the  
PXI-7811R timing and functionality without having to learn a low-level  
programming language or a hardware description language (HDL)  
traditionally used for FPGA design. With the LabVIEW FPGA Module,  
you create or download a custom virtual instrument (VI) to the FPGA.  
You can reconfigure the PXI-7811R device with a new VI at any time.  
You can use the LabVIEW Real-Time Module to communicate and control  
the PXI-7811R device while performing additional tasks, such as real-time  
floating-point processing and data logging.  
Note If you are using LabVIEW but not the LabVIEW FPGA Module, you can create VIs  
that run in LabVIEW to control existing FPGA VIs, but you cannot create new FPGAVIs.  
The PXI-7811R device has Flash memory that you can use to store VIs.  
You can configure VIs to load to the FPGA and to run when the device  
powers up.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LabVIEW FPGA Module 1.1 or later—required to develop  
custom FPGA VIs for the PXI-7811R device  
NI-RIO 1.1 or later—included with the PXI-7811R  
PXI/CompactPCI chassis and real-time PXI controller  
One of the following host computers, depending upon your  
application, running Windows 2000/XP:  
PC  
Laptop computer  
PXI/CompactPCI embedded controller  
At least one cable and device for connecting signals to the PXI-7811R  
CAT 5 Ethernet crossover cable if the real-time PXI system is not  
configured on a network. To connect the PXI system to a network port,  
use a standard CAT 5 10/100Base-T Ethernet cable.  
Installing Software  
The following instructions describe how to install the NI-RIO device  
drivers and LabVIEW.  
Installing LabVIEW, the LabVIEW Real-Time Module for ETS, and the  
LabVIEW FPGA Module  
Use the following sequence when installing LabVIEW, the LabVIEW  
Real-Time Module for ETS, and the LabVIEW FPGA Module. For more  
detailed information about software requirements, refer to the LabVIEW  
FPGA Release Notes.  
If you are using NI-RIO without LabVIEW, skip these steps and complete  
the steps in the Installing NI-RIO Device Drivers section.  
Note You must install LabVIEW 7.0 or later and the LabVIEW modules you will be using  
with the NI 7811R before installing the NI-RIO device drivers. For LabVIEW installation  
instructions, refer to the LabVIEW Release Notes.  
1. Install LabVIEW for Windows from the LabVIEW CD.  
2. Install the LabVIEW Real-Time Module for ETS from the LabVIEW  
Real-Time CD.  
3. Install LabVIEW FPGA from the LabVIEW FPGA CD.  
4. Install the NI-RIO device drivers. Refer to the Installing NI-RIO  
Device Drivers section for driver installation instructions.  
© National Instruments Corporation  
3
Getting Started with the NI 7811R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing NI-RIO Device Drivers  
Complete the following steps to install the NI-RIO device drivers that are  
included with the PXI-7811R device. If you are using LabVIEW, complete  
the installation instructions in the Installing LabVIEW, the LabVIEW  
Real-Time Module for ETS, and the LabVIEW FPGA Module section  
before installing the NI-RIO device drivers.  
1. Run setup.exe from the NI-RIO CD and follow the setup  
instructions.  
2. Follow the onscreen instructions until the Feature Tree window  
appears.  
3. In the Feature Tree window, select the components to install. You must  
install NI-VISA, NI-RIO, and NI Measurement & Automation  
Explorer (MAX).  
4. Follow the onscreen instructions to complete the driver installation.  
5. Reboot your computer.  
Installing Hardware  
This section describes how to unpack and install the PXI-7811R device.  
You can install the PXI-7811R in any available peripheral slot in the PXI  
or CompactPCI chassis.  
Note You must install the NI-RIO device drivers before installing the PXI-7811R device.  
Unpacking  
The PXI-7811R device ships in an antistatic package to prevent  
electrostatic discharge from damaging device components. To prevent such  
damage when handling the device, take the following precautions:  
Ground yourself using a grounding strap or by holding a grounded  
object, such as your computer chassis.  
Touch the antistatic package to a metal part of the computer chassis  
before removing the devices from the package.  
Caution Never touch the exposed pins of connectors.  
Remove the devices from the package and inspect the devices for loose  
components or any other sign of damage. Notify NI if the devices appear  
damaged in any way. Do not install damaged devices into the computer.  
Store the PXI-7811R in the antistatic envelope when not in use.  
Getting Started with the NI 7811R  
4
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
You can install the PXI-7811R in any available peripheral slot in the PXI  
or CompactPCI chassis. Complete the following steps to install the  
PXI-7811R device.  
Note You must install the software before installing the hardware. For software  
installation instructions, refer to the Installing Software section.  
1. Power off and unplug the PXI or CompactPCI chassis.  
2. Make sure there are no lit LEDs on the chassis. Wait for any lit LEDs  
to go out before continuing the installation.  
3. Remove the filler panel for the peripheral slot.  
4. Ground yourself using a grounding strap or by touching a grounded  
object, such as the PXI or CompactPCI chassis.  
5. Insert the PXI-7811R into the slot. Use the injector/ejector handle to  
fully inject the PXI-7811R into place.  
6. Screw the front panel of the PXI-7811R to the front panel mounting  
rails of the chassis.  
7. Visually verify the installation. Make sure the PXI-7811R is not  
touching other devices or components and that the PXI-7811R is  
fully inserted into the slot.  
8. Plug in and power on the PXI or CompactPCI chassis.  
Connecting Signals  
The PXI-7811R has four DIO connectors with 40 DIO lines per DIO  
connector.  
Figure 1 shows the I/O connector locations for the PXI-7811R. The  
I/O connectors are numbered starting at zero.  
© National Instruments Corporation  
5
Getting Started with the NI 7811R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NI PXI-7811R  
Reconfigurable I/ O  
Figure 1. PXI-7811R Connector Locations  
Getting Started with the NI 7811R  
6
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 2 shows the pin assignments for all I/O connectors on the  
PXI-7811R.  
34 68  
DIO38  
DIO39  
DIO37  
DIO35  
DIO33  
DIO31  
DIO29  
DIO27  
DIO26  
DIO25  
DIO24  
DIO23  
DIO22  
DIO21  
DIO20  
DIO19  
DIO18  
DIO17  
DIO36 33 67  
DIO34 32 66  
31 65  
30 64  
DIO32  
DIO30  
DIO28 29 63  
+5V 28 62  
+5V 27 61  
DGND 26 60  
DGND  
DGND 24 58  
25 59  
23 57  
22 56  
21 55  
DGND  
DGND  
DGND  
DGND 20 54  
19 53  
DGND  
DGND 18 52  
DGND 17 51  
DIO16  
16 50  
15 49  
DGND  
DGND  
DIO15  
DIO14  
DGND 14 48  
DGND 13 47  
DGND 12 46  
DGND 11 45  
DGND 10 44  
DIO13  
DIO12  
DIO11  
DIO10  
DIO9  
DIO8  
DIO7  
DIO6  
DIO5  
DIO4  
DIO3  
DIO2  
DIO1  
DIO0  
DGND  
DGND  
9
8
7
6
5
4
3
2
1
43  
42  
41  
40  
39  
38  
37  
36  
35  
DGND  
DGND  
DGND  
DGND  
DGND  
DGND  
DGND  
Figure 2. PXI-7811R I/O Connector Pin Assignments  
Caution Connections that exceed any of the maximum ratings of input or output signals  
on the PXI-7811R can damage the PXI-7811R and the computer. NI is not liable for any  
damage resulting from such signal connections. Refer to the PXI-7811R User Manual for  
the maximum input ratings for each signal.  
For detailed information about connecting I/O signals, refer to the  
NI 7811R User Manual.  
Cabling Options  
Accessing the signals on the I/O connectors requires at least one cable and  
one signal accessory. Table 1 summarizes the National Instruments cables  
available for use with the NI 7811R device.  
© National Instruments Corporation  
7
Getting Started with the NI 7811R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1. Cabling Options  
Description  
Cable  
SH68-C68-S  
For connecting signals from the DIO connector to the NI SCB-68 terminal  
block.  
NSC68-5050  
For direct connection of the NI 7811R and SSR backplanes.  
Routes signals to connectors that attach directly to SSR backplanes.  
Documentation Resources  
Refer to the following documentation for information about the  
LabVIEW FPGA Module, R Series hardware, and VIs necessary for your  
application.  
LabVIEW FPGA Module Release Notes—describes the software  
installation and other known software issues  
LabVIEW FPGA Module User Manual—describes the LabVIEW  
FPGA Module software and techniques for building applications in  
LabVIEW with the LabVIEW FPGA Module  
PXI-7811R User Manual—describes the electrical and mechanical  
aspects of the PXI-7811R device and contains information concerning  
its operation and programming  
LabVIEW Help—describes the VIs and function reference information  
CompactRIO R Series Expansion System Installation  
Instructions—describes how to install the CompactRIO R Series  
Expansion chassis and CompactRIO I/O modules  
Where to Go from Here  
Refer to the LabVIEW FPGA Module Release Notes for information about  
getting started with LabVIEW FPGA VIs and host VIs. This document also  
provides examples for verifying that your software and hardware are  
properly installed. To access this document, select Start»Programs»  
National Instruments»LabVIEW»Module Documents.  
CompactRIO™, LabVIEW™, MXI™, National Instruments™, NI™, ni.com™, and NI-VISA™ are  
trademarks of National Instruments Corporation. Product and company names mentioned herein are  
trademarks or trade names of their respective companies. For patents covering National Instruments  
products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on  
your CD, or ni.com/patents.  
*323792A-01*  
323792A-01  
Apr04  
© 2004 National Instruments Corp. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Miele Ventilation Hood 09 805 980 User Manual
Miele Washer Dryer WT946 IS WPS User Manual
Minolta Webcam Riva Zoom 135EX User Manual
NAD Stereo System C 445 User Manual
NEC Computer Monitor 77F User Manual
NEC Video Game Console EA221WME User Manual
NordicTrack Home Gym NTC40152 User Manual
Omnimount TV Mount 10041 User Manual
Oxygen Lawn Mower 78 6896 01 User Manual
Panasonic VCR AG 1070DC User Manual