National Instruments Camera Accessories FPT 1015 User Manual

FPT-1015  
User Manual  
FPT-1015 User Manual  
December 2006  
372051A-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important Information  
Warranty  
The FPT-1015 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by  
receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the  
warranty period. This warranty includes parts and labor.  
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in  
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments  
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects  
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.  
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any  
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by  
warranty.  
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In  
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document  
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National  
Instruments be liable for any damages arising out of or related to this document or the information contained in it.  
EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL  
INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING  
FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of  
the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against  
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in  
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service  
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the  
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside  
reasonable control.  
Copyright  
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,  
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National  
Instruments Corporation.  
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other  
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only  
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.  
Trademarks  
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section  
on ni.com/legalfor more information about National Instruments trademarks.  
Other product and company names mentioned herein are trademarks or trade names of their respective companies.  
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency,  
partnership, or joint-venture relationship with National Instruments.  
Patents  
For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txtfile  
on your CD, or ni.com/patents.  
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS  
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF  
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN  
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT  
INJURY TO A HUMAN.  
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE  
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,  
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS  
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE  
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,  
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR  
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER  
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF  
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY  
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,  
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,  
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS  
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION  
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT  
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY  
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER  
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT  
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance  
Compliance with FCC/Canada Radio Frequency Interference  
Regulations  
Determining FCC Class  
The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC  
places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only)  
or Class B (for use in residential or commercial locations). All National Instruments (NI) products are FCC Class A products.  
Depending on where it is operated, this Class A product could be subject to restrictions in the FCC rules. (In Canada, the  
Department of Communications (DOC), of Industry Canada, regulates wireless interference in much the same way.) Digital  
electronics emit weak signals during normal operation that can affect radio, television, or other wireless products.  
All Class A products display a simple warning statement of one paragraph in length regarding interference and undesired  
operation. The FCC rules have restrictions regarding the locations where FCC Class A products can be operated.  
Consult the FCC Web site at www.fcc.govfor more information.  
FCC/DOC Warnings  
This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions  
in this manual and the CE marking Declaration of Conformity*, may cause interference to radio and television reception.  
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department  
of Communications (DOC).  
Changes or modifications not expressly approved by NI could void the user’s authority to operate the equipment under the  
FCC Rules.  
Class A  
Federal Communications Commission  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC  
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the interference  
at their own expense.  
Canadian Department of Communications  
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.  
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.  
Compliance with EU Directives  
Users in the European Union (EU) should refer to the Declaration of Conformity (DoC) for information* pertaining to the  
CE marking. Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance  
information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line,  
and click the appropriate link in the Certification column.  
*
The CE marking Declaration of Conformity contains important supplementary information and instructions for the user or  
installer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conventions  
The following conventions are used in this manual:  
»
The » symbol leads you through nested menu items and dialog box options  
to a final action. The sequence File»Page Setup»Options directs you to  
pull down the File menu, select the Page Setup item, and select Options  
from the last dialog box.  
This icon denotes a note, which alerts you to important information.  
This icon denotes a caution, which advises you of precautions to take to  
avoid injury, data loss, or a system crash. When this symbol is marked on a  
product, refer to the Safety section of Appendix A, Specifications, for  
information about precautions to take.  
When symbol is marked on a product, it denotes a warning advising you to  
take precautions to avoid electrical shock.  
When symbol is marked on a product, it denotes a component that may be  
hot. Touching this component may result in bodily injury.  
bold  
Bold text denotes items that you must select or click in the software, such  
as menu items and dialog box options. Bold text also denotes parameter  
names.  
italic  
Italic text denotes variables, emphasis, a cross-reference, or an introduction  
to a key concept. Italic text also denotes text that is a placeholder for a word  
or value that you must supply.  
monospace  
Text in this font denotes text or characters that you should enter from the  
keyboard, sections of code, programming examples, and syntax examples.  
This font is also used for the proper names of disk drives, paths, directories,  
programs, subprograms, subroutines, device names, functions, operations,  
variables, filenames, and extensions.  
monospace bold  
Bold text in this font denotes the messages and responses that the computer  
automatically prints to the screen. This font also emphasizes lines of code  
that are different from the other examples.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1  
Introduction....................................................................................................................1-1  
VGA Port (DB15)............................................................................................1-1  
Chapter 2  
Mounting  
Important Safety Information ........................................................................................2-1  
Wall Mounting...............................................................................................................2-3  
Rack Mounting ..............................................................................................................2-5  
Desktop Stand Mounting ...............................................................................................2-6  
Power Adapter Mounting...............................................................................................2-6  
Appendix A  
Specifications  
Appendix B  
Display Timing Mode and OSD  
Appendix C  
Appendix D  
Technical Support and Professional Services  
Index  
© National Instruments Corporation  
vii  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
General Information  
This chapter includes an overview of the FPT-1015 human machine  
interface (HMI).  
Introduction  
The FPT-1015 is a 15 in. color TFT LCD flat panel monitor for industrial  
applications. With the optional touchscreen, this monitor is a user-friendly  
system control interface and can be easily transformed into a remote  
control system.  
In addition to its usual application as an LCD panel monitor, the FPT-1015  
includes a Direct VGA control signal input, making it compatible with  
industrial PCs and workstations.  
The onscreen display (OSD) function allows you to adjust the display and  
turn the backlight on and off.  
The chassis is made of durable steel. The front panel is made of Al-Mg with  
NEMA4/IP65 compliance.  
Connectors  
The FPT-1015 includes the following connectors.  
VGA Port (DB15)  
You can connect the FPT-1015 to a system via the external 15-pin DB-15  
connector.  
Note Before connecting a VGA cable between the FPT-1015 and a PC, be sure the vertical  
frequency is within the acceptable range if you have installed an operating system on the  
PC. If you have not installed an operating system, adjust the vertical frequency to fall  
within the range.  
© National Instruments Corporation  
1-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Chapter 1  
General Information  
USB Type B Touchscreen Connector  
The FPT-1015 includes this connector and a touchscreen cable if a  
touchscreen is installed. You must connect it to the PC USB port.  
DC 12 V Power In  
This connector connects to the DC 12 V switching power supply.  
FPT-1015 User Manual  
1-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2
Mounting  
This chapter explains how to mount the FPT-1015.  
Important Safety Information  
Before setting up the FPT-1015, read these safety instructions carefully.  
Disconnect this equipment from any AC outlet before cleaning. Use a damp  
cloth. Do not use liquid or spray detergents for cleaning.  
For plug-in equipment, the power outlet socket must be located near the  
equipment and must be easily accessible.  
Keep this equipment away from excessive humidity.  
Place this equipment on a reliable surface during installation. Dropping it  
or letting it fall may cause damage.  
The openings on the enclosure are for air convection. Protect the equipment  
from overheating. Do not cover the openings.  
Make sure the power source voltage is correct before connecting the  
equipment to the power outlet.  
Position the power cord so that it cannot be stepped on. Do not place  
anything over the power cord.  
All cautions and warnings on the equipment should be noted.  
If the equipment is not to be used for a long time, disconnect it from the  
power source to avoid damage by transient overvoltage.  
Never pour any liquid into an opening. This may cause fire or electrical  
shock.  
Never open the equipment. For safety reasons, only qualified service  
personnel should open the equipment.  
© National Instruments Corporation  
2-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 2  
Mounting  
If one of the following situations arises, have service personnel check the  
equipment:  
The power cord or plug is damaged.  
Liquid has penetrated into the equipment.  
The equipment has been exposed to moisture.  
The equipment does not work well, or you cannot get it to work  
according to the user manual.  
The equipment has been dropped and damaged.  
The equipment has obvious signs of breakage.  
Do not leave this equipment in an environment where the storage  
temperature may go below –20 °C (–4 °F) or above 60 °C (140 °F). Doing  
so could damage the equipment. The equipment should be in a controlled  
environment.  
Caution There is a danger of explosion if the battery is incorrectly replaced. Replace the  
battery only with the same or equivalent type recommended by the manufacturer. Discard  
used batteries according to the manufacturer’s instructions.  
The sound pressure level at the operator’s position according to  
IEC 704-1:1982 is no more than 70 dB (A).  
FPT-1015 User Manual  
2-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2  
Mounting  
Wall Mounting  
The FPT-1015 wall mounting kit is optional. As shown in Figure 2-1,  
screw the hook and wall-mounted brackets to the wall and attach the  
FPT-1015 to the bracket.  
Hook Bracket  
Wall-Mounting Bracket  
Figure 2-1. Wall Mounting  
© National Instruments Corporation  
2-3  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 2  
Mounting  
Panel Mounting  
Refer to Figure 2-2 and follow these steps to install the FPT-1015 in a  
panel:  
1. Place the panel-mounting brackets on the FPT-1015.  
2. Fasten the panel-mounting brackets with the screws.  
3. Insert the FPT-1015 in the panel.  
4. Tighten the screws to fasten the FPT-1015 to the panel.  
Figure 2-2. Panel Mounting  
FPT-1015 User Manual  
2-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 2  
Mounting  
Rack Mounting  
The rack mounting kit is optional. As shown in Figure 2-3, you can  
directly mount the FPT-1015 in a standard 19 in. rack and secure it  
with four screws.  
Figure 2-3. Rack Mounting  
© National Instruments Corporation  
2-5  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 2  
Mounting  
Desktop Stand Mounting  
The desktop stand kit is optional. As shown in Figure 2-4, attach the  
desktop stand bracket to the rear of the monitor with two screws.  
Figure 2-4. Desktop Stand Mounting  
Power Adapter Mounting  
Attach the power adapter bracket to the rear of the FPT-1015 monitor using  
four screws.  
Figure 2-5. Power Adapter Mounting  
FPT-1015 User Manual  
2-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
A
Specifications  
Physical  
Construction........................................... Heavy-duty steel chassis  
Front Panel ............................................. Al-Mg, NEMA4/IP65 compliant  
Control ................................................... Onscreen display (OSD) control  
pad on front side  
Mounting................................................ Panel, wallmount, rackmount  
(with rackmount kit), desktop, or  
VESA arm  
Cutout dimension ................................... 373.5 × 297.5 mm  
(14.7 in. × 11.71 in.)  
Weight.................................................... 4.5 kg (9.9 lb)  
Vibration (operating).............................. 5 to 17 Hz, double-amplitude  
displacement; 17 to 500 Hz,  
1.0 G peak to peak  
Power consumption................................ +12 V +/– 10% @ 2.5 A  
© National Instruments Corporation  
A-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Appendix A  
Specifications  
Dimensions  
383  
[15.07]  
270.59 308.26 372.6  
[10.65] [12.13] [14.66]  
307 [12.08]  
4.5  
18.5 48.13  
[0.17] [0.72] [1.89]  
214.1 [8.42]  
15 [0.59]  
296.6 [11.67]  
100 [3.93]  
75 [2.95]  
75  
100  
[2.95] [3.93]  
FPT-1015 User Manual  
A-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A  
Specifications  
Touchscreen  
Type ....................................................... 8 wire, analog resistive  
Resolution .............................................. 1024 × 1024  
Light transmission.................................. 75% (gouge hardness is greater  
than 4 H per ASTM D3363-92 for  
HCC01, HCG10, and HCG12)  
Controller ............................................... RS232 interface or USB 1.1  
OS support.............................................. Windows 9x/NT/2000/XP/  
CE 4.2, MS-DOS  
Lifespan.................................................. 1 million activations (typical)  
at a single point with a 5/8 in.  
diameter silicone finger with a  
350 g load at 2 touches per second  
Contact bounce....................................... <10 ms  
Operating voltage................................... 5 V (typical)  
Sheet resistance...................................... 350 +/– 22% Ω per square  
Linearity................................................. <1.5% full-scale linearity error in  
either direction  
Insulation resistance............................... >20 MΩ @ 25 VDC  
Test conditions ....................................... 4 H hardness, 0.04 in. stylus pen,  
350 g load  
Character activation life......................... >100,000 characters written  
within a 20 × 20 mm area on the  
touchscreen  
Chemical resistance................................ Hard coating is highly resistant to  
most solvents and chemicals  
Visible light transmission....................... 75% typical (>74% @ 550 nm  
test)  
Clarity..................................................... Clear finish—25%;  
antiglare finish—15%  
© National Instruments Corporation  
A-3  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A  
Specifications  
Sensor board ...........................................Chemical strengthened glass  
with 4 H hardness standard (test  
condition: ASTM D3363-92A)  
Ball drop test...........................................Able to bear a 225 g steel ball  
dropped from 660 mm elevation  
without breaking  
Accelerated aging ...................................100 h at 60 °C/95% relative  
humidity  
Thermal shock ........................................25 cycles (one cycle is 30 min.  
dwell alternating from –40 to  
85 °C with less than 10 min.  
transfer time  
LCD  
Display type............................................XGA TFT- LCD  
Display size.............................................15 in.  
Maximum colors.....................................262,000  
Maximum resolution...............................1024 × 768  
Viewing angle.........................................140° (H), 120° (V)  
Luminance ..............................................250 cd/m2  
Contrast ratio ..........................................500:1 (typical)  
Lamp lifetime (MTBF)...........................40,000 h  
Power Adapter  
Maximum output power .........................42 W  
AC input voltage.....................................100 to 240 VAC, 50–60 Hz  
Output voltage ........................................+12 V @ 3.5 A  
FPT-1015 User Manual  
A-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix A  
Specifications  
Environmental  
Maximum altitude.................................. 2,000 m  
Pollution Degree .................................... 2  
Indoor use only  
Touchscreen  
Operating temperature range.................. –20 to 50 °C, 2 weeks at  
50 °C/90% relative humidity  
Storage temperature high ....................... 70 °C, 240 h at ambient humidity  
Storage temperature low ........................ –40 °C, continuous at ambient  
humidity  
LCD  
Operating temperature............................ 0 to 50 °C (32 to 122 °F)  
Storage temperature ............................... –20 to 60 °C (–4 to 140 °F)  
Safety  
This product is designed to meet the requirements of the following  
standards of safety for information technology equipment:  
IEC 60950-1, EN 60950-1  
UL 60950-1, CSA 60950-1  
Note For UL and other safety certifications, refer to the product label or visit  
ni.com/certification, search by model number or product line, and click the  
appropriate link in the Certification column.  
© National Instruments Corporation  
A-5  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Appendix A  
Specifications  
Electromagnetic Compatibility  
This product is designed to meet the requirements of the following  
standards of EMC for electrical equipment for measurement, control, and  
laboratory use:  
EN 55024, CISPR 24 EMC requirements  
EN 55022, CISPR 22 Emissions; Class A  
EN 55011, CISPR 11 Emissions; Class A  
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A  
Note For EMC compliance, operate this device according to product documentation.  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives, as amended for CE marking, as follows:  
73/23/EEC; Low-Voltage Directive (safety)  
89/336/EEC; Electromagnetic Compatibility Directive (EMC)  
Note Refer to the Declaration of Conformity (DoC) for this product for any additional  
regulatory compliance information. To obtain the DoC for this product, visit ni.com/  
certification, search by model number or product line, and click the appropriate link  
in the Certification column.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling  
center. For more information about WEEE recycling centers and National Instruments  
WEEE initiatives, visit ni.com/environment/weee.htm.  
Cleaning  
If you need to clean the unit, use a soft, nonmetallic brush. Make sure that  
the unit is completely dry and free from contaminants before returning it to  
service.  
FPT-1015 User Manual  
A-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
B
Display Timing Mode and OSD  
Supported Input Timing Modes  
The FPT-1015 supports and automatically recognizes the frequencies listed  
in Table B-1.  
Table B-1. Supported Input Formats  
Vertical Frequencies  
Resolution  
640 × 480  
720 × 400  
800 × 600  
1024 × 768  
56 Hz  
60 Hz  
Yes  
70 Hz  
72 Hz  
Yes  
75 Hz  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Note Even if you use the preset timing, you may need to adjust functions such as  
horizontal period, CLK-delay, and display position. The adjusted values are memorized  
in every preset number.  
© National Instruments Corporation  
B-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Appendix B  
Display Timing Mode and OSD  
Keypad Interface  
Table B-2 lists key functions.  
Table B-2. Key Functions  
Key  
Auto  
Sel  
Function  
Executes the autoadjustment process.  
Shows the OSD screen or selects an item to change its  
setting.  
Moves between items or increases/decreases item  
settings.  
Press both keys simultaneously to lock/unlock the  
current settings.  
Exit  
Closes the selected item or the entire OSD screen.  
On/Off  
Turns the FPT-1015 backlight on and off. When  
power is off, the power indicator blinks.  
Power Indicator LED Status  
The keypad interface includes a dual-color LED driver to indicate status as  
follows:  
Green—The board detects an input signal and sends an output signal  
to the LCD panel.  
Orange—No signal detected, or out of range.  
Green and blinking—The backlight is off.  
No color—Power is off.  
FPT-1015 User Manual  
B-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix B  
Display Timing Mode and OSD  
OSD Function  
Each selected OSD function value is stored into LCD memory after an SEL  
signal input or timeout. The stored values are not affected if the power is  
off. However, the selected value is not available if a selected mode is  
changed or power is turned off before timeout.  
Table B-3 lists the OSD function menus.  
Table B-3. OSD Function Menus  
Main Menu  
Submenu  
Functionality  
Brightness  
Adjust the display  
brightness  
Contrast  
Color  
Contrast  
Adjust RGB channel  
contrast simultaneously  
9300k  
6500k  
Adjust selected RGB  
channel color  
User  
Position  
H.Position  
Move the input image  
capture window left or  
right  
V.Position  
Move the input image  
capture window up or  
down  
Phase  
Clock  
All Reset  
Adjust the ADC sample  
clock phase  
Adjust the number of  
clocks per line  
All Reset  
Reset menu parameters to  
factory default settings  
Information  
System input mode  
information and  
maximum range the  
screen supports  
© National Instruments Corporation  
B-3  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
C
Touchscreen  
This appendix explains how to install and configure the FPT-1015  
touchscreen.  
Introduction  
The FPT-1015 touchscreen uses advanced 8-wire resistive technology,  
providing more accurate sensing capacity than other technologies. The  
touchscreen is specially designed for tough industrial environments.  
Installing the Driver for Windows  
The touchscreen driver is on the driver CD included with the FPT-1015.  
To install the driver, locate the Windows Driver V4.1.1008folder. Run  
setup.exein that folder and follow the installation instructions.  
Configuring the Touchscreen  
After you install the touchscreen driver, the FPT-1015 automatically finds  
the new touchscreen controller board on rebooting. The touchscreen is  
connected, but not calibrated. Follow these steps to start calibration:  
1. After installation and rebooting, click the PenMount Monitor pm icon  
in the menu bar and select Control Panel.  
2. When the PenMount Control Panel appears, click Calibrate.  
PenMount Control Panel  
The PenMount Control Panel functions are Calibrate, Multiple Monitors,  
Setting, PenMount Rotating Functions, Tools, and About.  
Calibrate  
The Calibrate function includes two ways to calibrate your touchscreen.  
Standard calibration adjusts most touchscreens. Advanced calibration  
adjusts aging touchscreens.  
© National Instruments Corporation  
C-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Appendix C  
Touchscreen  
Standard Calibration  
When you click this button, arrows  
appear pointing to red squares. Use your  
finger or stylus to touch the red squares in  
sequence. After you touch the fifth red  
square, calibration is complete. To skip,  
press <Esc>.  
Note To access the Advanced Calibration option, go to the Tools tab and select Advanced  
Calibration.  
Advanced Calibration  
Advanced calibration uses 4, 9, 16, or  
25 points to effectively calibrate the  
linearity of aged touchscreens. Click  
this button and touch the red squares in  
sequence with a stylus. To skip, press  
<Esc>.  
Note The older the touchscreen, the more advanced calibration points you need for  
accurate calibration. Use a stylus during advanced calibration for greater accuracy.  
Plot Calibration Data  
When you select this function, a touch  
panel linearity comparison graph appears  
after you finish advanced calibration.  
The blue lines show linearity before  
calibration, and black lines show linearity  
after calibration.  
Multiple Monitors  
The Multiple Monitors function supports two to six touchscreen displays  
for one system. Each monitor requires its own PenMount touchscreen  
control board, installed inside the display or in a central unit. You must  
connect the control boards to the computer COM ports via the RS232  
interface. Driver installation procedures are the same as for a single  
monitor. Multiple Monitors supports the following modes:  
Windows Extend Monitor function  
Matrox DualHead multiscreen function  
nVidia nView function  
Note The Multiple Monitors function is for multiple displays only. Do not use this  
function with only one touchscreen display.  
FPT-1015 User Manual  
C-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix C  
Touchscreen  
Follow these steps to enable multiple displays:  
1. In the Multiple Monitors tab, check the Multiple Monitor Support  
box.  
2. Click Map Touch Screens to assign touch controllers to the displays.  
3. When the mapping screen message appears, click OK.  
4. Touch each screen as it displays Please touch this monitor.  
Following this sequence and touching each screen is called mapping  
the touchscreens.  
5. Touching all screens completes the mapping, and the desktop  
reappears on the monitors.  
6. Select a display and execute the Calibration function. A message to  
start calibration appears. Click OK.  
7. Touch this screen to start its calibrationappears on  
one of the screens. Touch the screen.  
8. Touch the red squaremessages appear. Touch the red squares in  
sequence.  
9. Continue calibration for each monitor by clicking Standard  
Calibration and touching the red squares.  
Note If you use a single VGA output for multiple monitors, do not use the Multiple  
Monitors function. Follow the regular procedure for calibrating each monitor.  
The rotating function is disabled if you use the Multiple Monitors function.  
If you change the display resolution or screen address, you must map the touchscreens  
again so the system understands where the displays are.  
Setting  
Use this tab to change the configuration for specific touchscreen  
applications, such as point-of-sales (POS) terminals, beep settings,  
stabilizing cursor, and automatic station detection.  
Touch Mode  
Allows the enabling and disabling of the  
mouse’s ability to drag onscreen icons.  
Mouse Emulation—This option allows  
the mouse to function normally and drag  
icons.  
© National Instruments Corporation  
C-3  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix C  
Touchscreen  
Click on Touch—This option allows the  
mouse to have only a click function, and  
dragging is disabled.  
Beep Sound Mode  
Enable Beep Sound—This option turns  
the beep function on and off.  
Beep on Pen Down—In this mode, the  
beep occurs when the pen goes down.  
Beep on Pen Up—In this mode, the beep  
occurs when the pen goes up.  
Kind of Sound—This option modifies the  
type of sound the beep makes.  
Beep on Both—In this mode, the beep  
occurs when the pen goes down and up.  
Beep Frequency—This option modifies  
the sound frequency.  
Beep Duration—This option modifies the  
sound duration.  
Cursor Stabilizer  
Select this option to reduce cursor  
vibration, or where there maybe be excess  
vibration. Normally, you should not  
select this option.  
PenMount Rotating Functions  
The PenMount driver for Windows supports several display rotation  
software packages, such as:  
Portrait Pivot screen rotation software  
The ATI display driver rotate function  
The nVidia display driver rotate function  
The SMI display driver rotate function  
The Intel 845G/GE display driver rotate function  
FPT-1015 User Manual  
C-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix C  
Touchscreen  
Configuring the Rotate Function  
Follow these steps to configure the rotate function:  
1. Install the rotation software package.  
2. Choose the rotate function in the software. The calibration screen  
appears automatically. Touch the point, and rotation is mapped.  
Note The rotate function is disabled if you use monitor mapping.  
Tools  
Draw  
This option tests the touchscreen  
operation. The display shows touch  
location. Click Draw to start. When you  
touch the screen with your finger or a  
stylus, the drawing screen registers touch  
activity such as left, right, up, down, pen  
up, and pen down.  
Click Clear Screen to clear the drawing.  
Advanced Calibration  
Right Button Icon  
This option enables or disables the  
Advanced Calibration Mode on the  
Calibration tab.  
This option shows or hides the icon for  
switching buttons and lets you select  
whether the icon is in the System Tray  
or on the desktop.  
Right Button Emulation  
This option enables or disables right  
button emulation.  
About  
The About panel displays information about the PenMount controller and  
driver version.  
© National Instruments Corporation  
C-5  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Appendix C  
Touchscreen  
PenMount Monitor Menu Icon  
The PenMount Monitor icon (pm) appears in the Windows menu bar when  
you turn on PenMount Monitor in PenMount USB Utilities.  
PenMount Monitor has the following functions:  
Control Panel  
Beep  
Brings up the PenMount Control Panel.  
Turns the beep on or off.  
Right Button  
When you select this function, a mouse  
icon appears. Click this icon to switch  
between right and left button functions.  
Exit  
Exits the PenMount Monitor function.  
FPT-1015 User Manual  
C-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ni.com  
 
D
Technical Support and  
Professional Services  
Visit the following sections of the National Instruments Web site at  
ni.comfor technical support and professional services:  
Support—Online technical support resources at ni.com/support  
include the following:  
Self-Help Resources—For answers and solutions, visit the  
award-winning National Instruments Web site for software drivers  
and updates, a searchable KnowledgeBase, product manuals,  
step-by-step troubleshooting wizards, thousands of example  
programs, tutorials, application notes, instrument drivers, and  
so on.  
Free Technical Support—All registered users receive free Basic  
Service, which includes access to hundreds of Application  
Engineers worldwide in the NI Discussion Forums at  
ni.com/forums. National Instruments Application Engineers  
make sure every question receives an answer.  
For information about other technical support options in your  
area, visit ni.com/servicesor contact your local office at  
ni.com/contact.  
Training and Certification—Visit ni.com/trainingfor  
self-paced training, eLearning virtual classrooms, interactive CDs,  
and Certification program information. You also can register for  
instructor-led, hands-on courses at locations around the world.  
System Integration—If you have time constraints, limited in-house  
technical resources, or other project challenges, National Instruments  
Alliance Partner members can help. To learn more, call your local  
NI office or visit ni.com/alliance.  
If you searched ni.comand could not find the answers you need, contact  
your local office or NI corporate headquarters. Phone numbers for our  
worldwide offices are listed at the front of this manual. You also can visit  
the Worldwide Offices section of ni.com/niglobalto access the branch  
office Web sites, which provide up-to-date contact information, support  
phone numbers, email addresses, and current events.  
© National Instruments Corporation  
D-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                   
Index  
A
About function, C-5  
electromagnetic compatibility  
specifications, A-6  
environmental specifications, A-5  
LCD, A-5  
C
Calibrate function, C-1  
calibration  
advanced, C-2  
plot calibration data, C-2  
standard, C-2  
connectors, 1-1  
CE compliance specifications, A-6  
cleaning, A-6  
connectors, 1-1  
DC 12 V power in, 1-2  
electromagnetic compatibility  
specifications, A-6  
environmental specifications, A-5  
LCD, A-5  
touchscreen, A-5  
introduction, 1-1  
D
DC 12 V power in, 1-2  
desktop stand mounting, 2-6  
diagnostic tools (NI resources), D-1  
dimensions, A-2  
keypad  
display timing mode, B-1  
documentation  
functions (table), B-2  
interface, B-2  
LCD specifications, A-4  
conventions used in the manual, v  
NI resources, D-1  
drivers (NI resources), D-1  
© National Instruments Corporation  
I-1  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
mounting, 2-1  
desktop stand mounting, 2-6  
keypad  
panel mounting, 2-4  
power adapter mounting, 2-6  
rack mounting, 2-5  
KnowledgeBase, D-1  
wall mounting, 2-3  
OSD  
function, B-3  
menus (table), B-3  
PenMount Monitor menu icon, C-6  
PenMount rotating functions, C-4  
configuring, C-5  
physical specifications, A-1  
power adapter specifications, A-4  
power indicator LED status, B-2  
safety  
mounting, 2-1  
desktop stand mounting, 2-6  
panel mounting, 2-4  
information, 2-1  
specifications, A-5  
power adapter mounting, 2-6  
rack mounting, 2-5  
specifications, A-1  
supported input formats (table), B-1  
supported input timing modes, B-1  
touchscreen, C-1  
Multiple Monitors function, C-2  
installing driver for Windows, C-1  
introduction, C-1  
PenMount Control Panel, C-1  
specifications, A-3  
Equipment specifications, A-6  
O
OSD, B-1  
H
help  
technical support, D-1  
panel mounting, 2-4  
PenMount Control Panel, C-1  
About function, C-5  
I
Calibrate function, C-1  
Multiple Monitors function, C-2  
Setting function, C-3  
introduction, 1-1  
Tools function, C-5  
FPT-1015 User Manual  
I-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ni.com  
Index  
PenMount Monitor menu icon, C-6  
PenMount rotating functions, C-4  
configuring, C-5  
physical specifications, A-1  
plot calibration data, C-2  
power adapter  
technical support, D-1  
Tools function, C-5  
mounting, 2-6  
touchscreen, C-1  
specifications, A-4  
configuring, C-1  
environmental specifications, A-5  
installing driver for Windows, C-1  
introduction, C-1  
R
PenMount Control Panel, C-1  
About function, C-5  
rack mounting, 2-5  
rotating functions, C-4  
Calibrate function, C-1  
Multiple Monitors function, C-2  
Setting function, C-3  
Tools function, C-5  
S
PenMount Monitor menu icon, C-6  
PenMount rotating functions, C-4  
configuring, C-5  
safety  
information, 2-1  
specifications, A-5  
Setting function, C-3  
software (NI resources), D-1  
specifications, A-1  
CE compliance, A-6  
cleaning, A-6  
training and certification (NI resources), D-1  
troubleshooting (NI resources), D-1  
dimensions, A-2  
USB type B touchscreen connector, 1-2  
electromagnetic compatibility, A-6  
environmental, A-5  
LCD, A-5  
touchscreen, A-5  
LCD, A-4  
safety, A-5  
wall mounting, 2-3  
Waste Electrical and Electronic Equipment  
compliance specifications, A-6  
Web resources, D-1  
touchscreen, A-3  
Waste Electrical and Electronic  
Equipment compliance, A-6  
standard calibration, C-2  
support, technical, D-1  
© National Instruments Corporation  
I-3  
FPT-1015 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NEC Flat Panel Television split screen Model User Manual
Nikon Camcorder 26317 User Manual
Nikon Camera Accessories WC E68 User Manual
Novatel Home Theater System GM 14915105 User Manual
Omega Vehicle Security Welding System LDP1XX 21 User Manual
Oreck Vacuum Cleaner 2310RD User Manual
Packard Bell Laptop TK11BZ User Manual
Panasonic Cordless Drill EY6932 User Manual
Panasonic Network Card 2SD1938F User Manual
Parker Hannifin Home Theater Server acr motion max api users Manual User Manual