INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE
EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY WARNOCK HERSEY LTD. TO STANDARDS: CSA B366.2 , ULCS627, ULC S628, UL 1482.
MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS
FREE STANDING MODELS EPA 1100, 1100L, 1100C, 1400, 1400L
&
1900
INSERT MODELS
EPI 1101, 1401
WARNING:
If this unit is not properly installed, a house fire may result.
FOR YOUR SAFETY
Follow the installation directions. This unit can be very hot when burning. Combustible materials
such as firewood, wet clothing, etc. placed too close can catch fire. Children and pets must be
kept from touching the unit when it is hot. The chimney must be sound and free of cracks. Before
installing your unit, contact the local building or fire authority and follow their guidelines.
Operate only with door tightly closed. Burn wood directly on firebricks. Do not use a grate or
elevate the fire. At least 14 square inches (90 sq.cm.) of outside air must be admitted to the room
or directly to the unit through a 4 inch (10cm.) diameter pipe. This unit is designed to burn natural
wood only. Higher efficiencies and lower emissions generally result when burning air dried sea-
soned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. Do not start a
fire with chemicals or fluids such as gasoline, engine oil, etc. Do not burn treated wood, coal,
charcoal, coloured paper, cardboard, solvents or garbage which tend to produce more pollution
than wood. Do not let the unit become hot enough for any part to glow red.
KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output rates
that exceed design specifications can result in steel distortion and damage.
Wolf Steel Ltd., 24 Napoleon Rd.,
Barrie, ON., Canada L4M 4Y8 (705)721-1212
Fax: (705)722-6031
Email: [email protected]
R-2000
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
3
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
TABLE of CONTENTS
PG 2-4 INTRODUCTION
10-11 FINISHING
Warranty
Brick Installation
General Information
Care of Plated & Enamelled Parts
Care of Glass
Ornamental Trivet Installation
Door and Handles Installation
Pedestal Trim Installation
11-13 OPERATINGINSTRUCTIONS
Achieving Proper Draft
5-6 INSTALLATION
Installing the Legs
Alcove Installation
Stove Installation
Chimney Connection
Adding Chimney Sections
Outside Air
Fire Extinguishers and Smoke Detectors
Fuel Loading and Burn Cycle
Flash Fire
Extended Fire
Smoking
6-7 MOBILE HOME INSTALLATION
Ash Removal Procedures
13 MAINTENANCE
Creosote Formation and Removal
Runaway or Chimney Fire
Gasket Replacement
Venting
Outside Air
7-8 FIREPLACE INSERT
INSTALLATION
Prior to Installation
Installation into a Masonry Fireplace
Installation into a Factory Built Fireplace
Door Removal
14 WOODPILEMAINTENANCE
& SERVICE HISTORY
8-9 OPTIONAL FAN
INSTALLATIONS
Stove Models
15-16 REPLACEMENTS
Ordering Replacement Parts
Replacement Parts
Accessories
Insert Models
SPECIFICATIONS MODEL 1100, MODEL 1101 MODEL 1400 MODEL 1401
MODEL 1900
1100C&1100L
(INSERT)
& 1400L
(INSERT)
WIDTH
25 1/2 in. (65 cm)
28 in. (71 cm)
25 1/2 in. (65 cm)
25 1/2 in. (65 cm)
25 1/2 in. (80 cm)
31 1/2 in. (65 cm)
DEPTH
22 1/2 in. (57 cm)
24 in. (61 cm)
16 1/2 to 21 in.
27 in. (69 cm)
27 in. (69 cm)
14 1/2 in. (37 cm)
DEPTH BEHIND FLASHING
(42 to 54 cm)
11” (27.94 cm)
14” (35.56 cm)
FLUE CENTERLINE TO REAR
6 1/2” (16.51 cm)
7 1/2” (19.05 cm)
12 3/4” (32.39 cm)
5 1/2” (13.97 cm)
12 3/4” (32.39 cm)
7 1/2” (19.05 cm)
12 3/4” (32.39 cm)
FLUE CENTERLINE TO SIDE 12 3/4” (32.39 cm)
PEDESTAL MODEL
CAST MODEL
33 1/4 in. (84cm)
28 1/2 in. (72cm)
32 in. (81cm)
21 1/4 in. (55cm)
33 1/4 in. (84cm)
21 1/4 in. (54cm)
33 1/4 in. (84cm)
HEIGHT
LEG MODEL
32 in. (81cm)
18 x 18 x 12 in.
(46 x 46 x 31 cm)
2.25 ft3 (0.06 m3)
1000-1800 ft2
(92-167 m2)
CHAMBER (D.W.H.)
13-1/2x18x12in.
(34 x 46 x 31 cm)
1.7 ft3 (0.05 m3)
600-1200 ft2
13-1/2x18x12in.
(34 x 46 x 31 cm)
1.7 ft3 (0.05 m3)
600-1200 ft2
18 x 18 x 12 in.
(46 x 46 x 31 cm)
2.25 ft3 (0.06 m3)
1000-1800 ft2
(92-167 m2)
22 1/2 x 18 x 12 3/4 in.
(57 x 46 x 32 cm)
3.0 ft3 (0.08 m3)
1500-2000 ft2
CAPACITY
APPROX. AREA HEATED*
(56-112 m2)
(56-112 m2)
(139-186 m2)
HEAT OUTPUT (HIGH BURN)**
DURATION LOW FIRE*
WEIGHT W/O BRICKS
WEIGHT OF BRICKS
50,000 BTU
50,000 BTU
60,000 BTU
60,000 BTU
70,000 BTU
7 HOURS
7 HOURS
9 HOURS
9 HOURS
12 HOURS
215 lbs (97.5 kg)
110 lbs (50 kg)
185 lbs (83.9 kg)
120 lbs (54.4 kg)
250 lbs (113 kg)
145 lbs (66 kg)
250 lbs (113 kg)
145 lbs (66 kg)
285 lbs (129 kg)
114 lbs (52 kg)
*FIGURES WILL VARY CONSIDERABLY WITH INDIVIDUAL CONDITIONS.
** WOLF STEEL LTD. ESTIMATED REALISTIC BTU/H WITH HARDWOOD LOGS AND REGULAR REFUELING.
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
4
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which
contains chemicals known to the State of
California to cause cancer, birth defects, or other
reproductive harm.
INTRODUCTION
GENERAL INFORMATION
Except for their different depths, models 1100, 1400,
1900 and the fireplace inserts 1101 and 1401 are iden-
tical and use the same burning principles. They were
specifically designed over many months of research to
meet the 1990 U.S.A. EPA particulate emission stand-
ards and have been extensively tested in Canadian and
American laboratories. This system is the most effi-
cient, simple and trouble free we know and works as
follows:
PEDESTAL MODELS ONLY
If the outside air feature of the stove is utilized, you will
never experience a shortage of combustion air. If you
choose not to utilize outside air and experience draft or
smoking problems, you may need to open a door or
window.
WARNING: Burning your unit with the ash dump
door open or ajar creates a fire hazard that may
result in discoloration to the gold plated door, in-
ternal damage to the stove or a house and/or chim-
ney fire.
To ensure that the ash dump door is tightly closed, al-
low the door to snap shut dislodging anything (ashes
or pieces of coal) that may be stuck in the opening.
Combustion air enters through two holes in the bottom
covered by a single draft control. Air from the front hole
goes up on either side of the door into a preheating
airwash located across the top and then down the win-
dow to feed the fire and also to ensure that the glass
remains clean. Air from this hole also feeds directly
into the combustion chamber at hearth level. Second-
ary air from the rear hole travels up the back in the
secondary air housing to the manifold located at the
top and shoots out laterally to oxidize the gases below
the smoke exit.
The combustion chamber is lined with high tempera-
ture firebrick on 2 sides, the back and across the bot-
tom, with a layer of fibre baffles at the top to maintain a
high temperature in the combustion chamber so that
gases mixing with the preheated air from the second-
ary air manifold tube are easily ignited and burned. In-
deed, it is fascinating to watch blue flames flickering
much of the time from the manifold. The stove sides
and back are shielded to direct the heat upwards and
forwards into the room.
LEG MODELS ONLY
If you experience smoking problems, you may need to
open a door, a window or otherwise provide some
method of supplying combustion air to the unit.
CARE OF ALL PLATED AND
ENAMELLED PARTS
Do not use abrasive cleaners to clean these parts.
Buff lightly with a clean dry cloth.
Prolonged high temperature burning with the door ajar
may cause a permanent rainbowing effect on the lower
edge of a gold plated door.
Porcelain enamel components must be handled with
care. The baked-on finish is "glass". If struck, it will chip.
Touch-up paint is available through your Napoleon
dealer.
CARE OF GLASS
If the glass is not kept clean permanent discolouration
and / or blemishes may result. Normally a hot fire will
clean the glass. The most common reasons for dirty
glass include; not using sufficient fuel to get the stove
thoroughly hot, using green or wet wood, closing the
draft so far that there is insufficient air for complete com-
bustion. If it is necessary to clean the glass, use a soft
cloth with a nonabrasive cleaner.
DO NOT CLEAN GLASS WHEN HOT!
The glass is very strong but do not let burning fuel rest
against it and always close the door gently. If the glass
should ever crack while the fire is burning, do not open
the door until the fire is out and do not operate the stove
again until the glass has been replaced with a new 5mm
thick plate of ceramic glass, available from your Napo-
leon / Wolf Steel Ltd. dealer.
DO NOT SUBSTITUTE MATERIALS.
TO REMOVE THE GLASS: When the unit is cool, open the
door and remove the screws and brackets holding the
glass in place. Remove all broken glass. Wrap the edges
of the new glass with a U-shaped strip of fiberglass
gasket, covering 1/4" on each side. Place the glass with
the fiberglass gasket in position and replace the brackets
and screws. When finished, you should be able to move
the glass slightly, horizontally and vertically.
FIGURE 1
Be sure to provide sufficient combustion air. There are
many other appliances in your home competing for air
such as: a kitchen range hood, forced air heating de-
vices or a bathroom exhaust fan.
Expansion / contraction noises during heating up and
cooling down cycles are normal and to be expected.
After extended periods of non-operation such as fol-
lowing a vacation or a warm weather season, the fire-
place may emit a slight odour for a few hours. This is
caused by dust particles in the firebox burning off. Open
a window to sufficiently ventilate the room.
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
5
STOVE INSTALLATION
INSTALLING THE LEGS
STOVE INSTALLATION
If the stove is to be installed
on a combustible floor, it must be
placed on a approved non-com-
bustible hearth pad, that extends
8" (200mm) beyond the stove
sides and back, and 18" (455mm)
To avoid being damaged during shipping, the stove
has been bolted to the pallet and must be unbolted
before the stove can be installed.
FIGURE 2A
1. Remove the 4 nuts and
washers from the underside
of the pallet.
2. Lift the stove up and
away from the pallet to
clear the threaded studs
sticking through the pallet.
Place the stove on its back
onto a protective surface
such as a carpet or blan-
ket to avoid scratches dur-
ing leg installation.
to the front.
FIGURE 4A
FIGURE 4B
SINGLE WALL CHIMNEY CONNECTOR*
1100/1100L
1400/1400L
1900
A 12" (305mm) 12" (305mm)
B 10" (254mm) 12" (305mm)
22" (560mm)
12" (305mm)
8" (205mm)
C
6" (152mm)
6" (152mm)
DOUBLE WALL CHIMNEY CONNECTOR
1100/1100L
1400/1400L
1900
A 10" (254mm) 10" (254mm)
22" (560mm)
12" (305mm)
8" (205mm)
B
C
6" (152mm)
2" (50mm)
6" (152mm)
4" (102mm)
CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL
AUTHORITIES.
*
CHIMNEY CONNECTION
FIGURE 2B
Vent the stove into a masonry chimney or an approved,
insulated solid-fuel stainless-steel chimney with as short
and straight a length of six-inch (150mm) diameter
smoke pipe as possible. Connection to a masonry chim-
ney must be by a metal or masonry thimble cemented
in place. An insulated stainless steel chimney must be
supported at the ceiling or roof and its installation must
comply with its manufacturer's instructions.
3. Remove the four additional nuts from each of the four
studs.
4. Use four of the nuts and washers removed above to
install the legs as illustrated in FIGURES 2a & 2b.
5. Lift the stove up and gently set down on all four legs.
Do not pivot unit up on its legs, as this could result in
damage to the legs.
ALCOVE INSTALLATION
THE TOTAL HORIZONTAL VENT LENGTH
SHOULD NOT EXCEED 40% OF THE CHIMNEY
HEIGHT ABOVE THE STOVE.
Model 1100 only may be installed, using a listed double
wall connector, such as Security DL6 in Canada, the
Simpson Duravent Plus DVL in the USA or an equiva-
lent double wall connector, into an alcove having a depth
of no more than 4 feet and a height of at least 7 feet.
The minimum clearances are as shown in FIGURE 3.
All horizontal smoke pipe must slope slightly
upwards a minimum of 1/4" per foot (6mm/
0.3m) and all connections must be tight and
secured by three sheet metal screws equally
spaced.
An uninsulated smoke pipe shall not pass
through an attic, roof space, closet or similar
concealed space, or through a floor, ceiling,
wall or partition, or any combustible construc-
tion.
6"
9"
4 FOOT
14"
MAX.
23"
ALCOVE
FIGURE 3
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
6
DO NOT USE ANY MAKESHIFT MATERIALS
DURING INSTALLATION.
MOBILE HOME
INSTALLATION
1. Move the stove into position with the flue centered,
midpoint between two joists to prevent having to cut them.
Use a plumb bob to line up the centre.
2. Cut and frame an opening in the roof to provide a 2"
clearance between the outside of the chimney and any
combustible material.
PEDESTAL MODEL 1100 IS APPROVED FOR IN-
STALLATION IN MOBILE HOMES IN BOTH
CANADA AND THE UNITED STATES.
DO NOT FILL THIS SPACE WITH ANY TYPE
PEDESTAL MODEL 1400 IS APPROVED FOR IN-
STALLATION IN MOBILE HOMES IN THE
UNITED STATES ONLY.
OF MATERIAL.
Nail headers between the joist for extra support.
Firestop spacers must be placed on the bottom of each
framed opening in any floor or ceiling that the chimney
passes through.
3. Hold a plumb bob from the underside of the roof to
determine where the opening in the roof should be. Cut
and frame the roof opening to maintain proper 2" clear-
ances.
FIGURE 8
The pedestal base must be firmly bolted to the floor
with 1/4 inch lag bolts. Minimum clearances to
combustibles are as shown in FIGURE 8.
HEADERS
FIGURE 9
VENTING
Connect the stove to a
chimney system using
a listed double wall con-
nector, Security DL6
in Canada or Dura
Vent DVL in the U.S.A.
Use chimney system
listed to ULC S629 in
Canada or either of
Simpson Dura-Vent
chimney models SDP
or Dura Tech in the
U.S.A.
RAIN CAP
FIRESTOP SPACER -
UNDERSIDE OF JOIST
MOBILE HOME
ROOF FLASHING
FIGURE 5
RADIATION SHIELD
ADDING CHIMNEY SECTIONS
Add chimney sections, twist lock-
ing (clockwise) securely, to the re-
quired height. The chimney must 2 FT.
CEILING SUPPORT
TRIM COLLAR
extend, at least, 3 feet above its MIN.
3 FT.
10 FT.
MIN.
point of contact with the roof and
at least 2 feet higher than any
wall, roof or building within 10 feet.
FIGURE 6. If your chimney sys-
tem is enclosed within the attic
area, a rafter radiation shield is
required.
PEDESTAL MODELS
OUTSIDE AIR
The chimney must be
installed in accordance
with the manufacturer's
instructions. Use only
specified components
with no substitutions.
The chimney and pipe
must extend at least 8
STOVE BOLTED
TO FLOOR
HEARTH PAD
FIGURE 6
OUTSIDE AIR CONNECTION
THROUGH WALL OR FLOOR
If possible connect the
air intake at the
pedestal's back or
bottom to the outside
with a 4 inch (100mm)
diameter fresh air kit
available at your
Napoleon/Wolf Steel
Ltd. dealer. Follow
detailed instructions
under "Mobile Home
Outside Air".
feet above the stove and 3 feet above the highest point
of the roof. Install a rain cap at the top which will not
impede the smoke exhaust. The chimney must be sup-
ported at the ceiling or roof so that its weight does not
rest on the stove.
It must be installed between ceiling joists, with radia-
tion shield and roof flashing, so that the structural
strength, insulation and waterproof qualities of the home
are not lessened. Seal with silicone to maintain a va-
pour barrier at the chimney and outside air pipe
penetrations.
FIGURE 7
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Do NOT remove bricks or mortar from the fireplace. In
case of an outside air inlet or ash dump, fill with fiberglass
insulation. Adhere to minimum clearances as shown in
FIGURE 10.
OUTSIDE AIR
Connection from the stove's air intake to the outside is
mandatory in mobile homes only, either through a hole
in the wall to line up with the knockout in the pedestal
back, or through a hole in the floor to line up with the
hole in the pedestal base. Use a fresh air kit. Secure
the 4 inch diameter aluminum liner by flaring the end
once it is inserted through the 4-1/2 inch diameter hole
in either the back or base of the pedestal. If the air in-
take is through the floor, the hole in the pedestal back
must be covered with sheet metal to avoid cold air spill-
age into the room. A cover plate is available from your
Wolf Steel Ltd. dealer. Avoid cutting away floor joists,
wall studs, electrical wires or plumbing. Seal around the
outside pipe with insulation to prevent drafts.
Do NOT place any
combustible materi-
als (furniture, fire-
28" TO MANTLE
COMBUSTIBLE
PROTRUDING
SIDE FACINGS
wood, etc.) within 48
inches in front or 36
inches at the side of
the insert.
17"
FIGURE 10
Combustible material must not protrude more that
1" to the side of the insert or between the mantle
and the top of the insert.
INSTALLATION INTO A MASONRY
If room air starvation occurs because the fresh air
intake is blocked with ice, leaves, etc., or because
the stove door was left open, or due to a strong
exhaust fan operating etc., dangerous fumes and
smoke from the operating stove could be drawn
inFto tIhRe roEomP. LACE INSERT
FIREPLACE
1. Remove the fireplace damper or fasten it perma-
nently open.
2. Measure the throat of the fireplace and mark this
shape on a piece of 24 gauge sheet metal (flue cover);
cut a six-inch (150mm) hole to lie directly below the
fireplace flue opening. Allow two inches of material for
a flange on all sides and cut to these measurements.
Bend down the flanges. If you have never done this
before, it might be a good idea to make a cardboard
pattern and test it first. Fasten this flue cover in posi-
tion as high as possible with two masonry screws per
side through the flanges into the fireplace. FIGURE 11.
INSTALLATION
Your EPI 1101 and 1401 insert firebox is the exact du-
plication of the clean-burning technology found in all Na-
poleon EPA certified freestanding stoves and in particu-
lar that of the EPA 1100 and 1400. External modifica-
tions have been made to allow its installation as a "func-
tional fireplace insert" with a heat circulating blower sys-
tem and a means of enclosing the solid fuel burning fire-
place cavity for greater heating efficiency.
LISTED
CHIMNEY
LINER
2"
DAMPER
FLANGE
REMOVED OR
FASTENED
OPEN
The EPI 1101 insert must be installed into a solid fuel burn-
ing fireplace that is at least 16 1/2 to 21 inches deep, 28 1/
2 inches wide and 21 1/2 inches high with an approved
lined chimney at least 15 feet high (4.6m).
FLUE
FLUE COVER
INSTALLATION
CONNECTOR
Your EPI 1401 fireplace insert must be installed only into a
solid fuel burning fireplace that is at least 14 inches deep
26 inches wide and 22 inches high with an approved lined
chimney at least 15 feet high (4.6m). This minimum re-
cess can only be achieved if the opening height is suffi-
cient enough to allow the connector to fit under the non-
combustible facing. The fireplace and chimney must be
constructed in accordance with all national and local build-
ing code standards.
MODEL 1401 Illustrated
FIGURE 11
In Canada: Install a listed 6 inch diameter flexible
stainless steel liner from the top of the chimney to the
insert flue collar. Attach a stainless steel liner connec-
tor or elbow to the liner and insert onto the flue collar.
Fasten with three screws. Secure the top of the liner to
the chimney cap using a liner support and chimney
flashing. Cap the top of the chimney liner assembly
using an approved rain cap.
In the United States: While it is not required, it is
recommended that a chimney liner be installed that is
continuous from the insert to the top of the chimney,
particularly when the insert is installed in a basement.
For this type of connection, use the "In Canada" instal-
lation instructions above.
HINT FOR INSTALLING PORCELAIN
ENAMELINSERTS:
Ensure the base of the porcelain side pan-
els are protected from rubbing against the
hearth when sliding your insert into the
masonry fireplace.
PRIOR TO INSTALLATION
Clean all ashes out of the inside of the fireplace. Make
sure that the chimney and fireplace are free of cracks,
loose mortar, creosote deposits, blockage or other signs
of deterioration. If necessary, have any repair work done
by a qualified professional before installing the insert.
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
8
In the United States, continued:
If a continuous liner is not installed, a "direct flue con-
nection" must be made. The direct flue connection re-
quires a non-combustible connector that extends from
the insert into the chimney flue liner and also that the
installed flue cover be sealed below the entry point of
the connector to prevent dilution of combustion prod-
ucts in the chimney flue with air from inside the house.
Cap the top of the chimney using an approved rain cap.
OPTIONAL FAN
INSTALLATION
Drywall dust will penetrate into the fan bearings,
causing irreparable damage. Care must be taken
to prevent drywall dust from coming into contact
with the fan or its compartment. Any damage re-
sulting from this condition is not covered by the
warranty policy.
1401 INSERT MODEL
An optional low clearance flue connector is available
to facilitate hook up into a tight fitting fireplace. Consult
your local dealer for details.
Use of the fan increases the output of heat.
STOVE MODELS: Provisions have been made on
the stove to install an optional blower kit (EP62-1) that
comes complete with a variable speed switch to turn
the blower on and off, as well as adjusting the blower
speed. An optional thermostatic sensor control kit,
EP36, to thermally activate the fan is also available.
INSTALLATION INTO A FACTORY BUILT
FIREPLACE.
The following installation requirements must be ob-
served when installing solid fuel burning inserts into
factory built fireplaces.
1. The factory built fireplace must be listed per UL 127 LEG MODELS ONLY
or ULC S610.
Note: if the optional blower ( EP62-1) is installed,
2. Clearances to any combustible material surround-
ing this insert as identified in Figure 10 must be fol-
lowed. These clearance requirements supersede any
pre-existing facing material clearances listed for the
factory built fireplace.
the blower guard (W320-0011) must be installed.
This guard is available from your Napoleon dealer.
Attach the mounting bracket to the
blower assembly. Then attach the
mounting bracket to the back of your
stove, push on the variable speed
knob and plug into any grounded
electrical outlet.
3. Installation must include a full height listed chimney
liner meeting HT requirements (2100°F) per 1777 (U.S.)
or ULC S635 (Canada). The liner must be securely at-
tached to the insert flue collar and the chimney top.
4. Means must be provided to prevent room air pas-
sage to the chimney cavity of the fireplace. This may
be accomplished by sealing the damper area around
the chimney liner, or sealing the fireplace front.
5. The air flow within and around the fireplace shall not
be altered by the installation of the insert (i.e. no lou-
vres or cooling air inlet or outlet ports are blocked),
unless specifically tested as such for each factory built
fireplace manufacturer and model line. (Note - using a
louvred face plate (surround) complies with this require-
ment)
MOUNTING
BRACKET
BLOWER
ASSEMBLY
VARIABLE
SPEED
SWITCH
6. Alteration of the fireplace in any manner is not per-
BLOWER GUARD
mitted with the following exceptions;
a. external trim pieces which do not affect the opera-
tion of the fireplace may be removed providing they
can be stored on or within the fireplace for reassembly
if the insert is removed.
b. the chimney damper may be removed to install
the chimney liner.
7. Circulating air chambers (i.e. in a steel fireplace liner
or metal heat circulator) shall not be blocked.
8. Means must be provided for removal of the insert to
clean the chimney flue.
FIGURE 12
INSERT MODELS:
The 1401 insert comes equipped with two fans, while
the 1101 has one fan. These fans are thermally acti-
vated. Depending on the intensity of the fire, the fans
will start 15-30 minutes after lighting. The heat sensor
for the 1401 is located on the right hand side of the unit
and the 1101 has a heat sensor located at the back on
the blower access door. When first starting the fire, the
sensor may be impeded by a large log or an unevenly
burning fire, causing the fans to cycle on and off. To
control this, either build your fire up evenly or turn down
the fans until the right side of the firebox is hot.
9. Inserts that project in front of the fireplace must be
supplied with appropriate support means.
10. A permanent metal warning label must be attached
to the back of the fireplace stating that the fireplace
must be restored to its original condition for safe use
without the insert.
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
9
1101 FAN SERVICE OR REPLACEMENT
1401 FAN SERVICE OR REPLACEMENT
1. Turn off all electrical power to the insert. Remove the 1. Turn off all electrical power to the insert. Remove the
glass door and set aside in a safe place.
2. Remove the top right
side bricks from inside
the firebox, 4-#7's and 2-
#2's. Then remove the
rest of the side and back
bricks from the right side
of the 1101 insert. It is not
necessary to remove the
bottom bricks.
glass door and set aside in a safe place.
2. Remove the two screws from the outer edge of the
side panel(s).
3. Push the side panel toward the door and pull away
from the insert, releasing the panel from the keyed slot.
4. Service or replace the fan(s) as required.
5. Re-install the side panel(s) by reversing the proce-
dure.
GASKET
THERMAL SWITCH
3. The access panel can
be removed by taking out
the 8 #10 self taping
screws. A 5/16" nut driver
will be required to com-
plete this job. Unplug
wires from the thermal
switch on the panel. See
FIGURE 13.
G
B
HEAT
SENSOR
W
FIGURE 13
FIGURE 16
4. Remove the securing wingnut from the fan mounting
bracket, slide the bracket to the right and rotate the left
side of the assembly out of the cavity to clear the blower
motor. Disconnect the two wires from the fan motor. Re-
move the ground wire from the fan mounting bracket,
then the assembly can be taken out of the rear cavity
through the access door opening.
5. Remove the 3 screws that hold the fan to the mount-
ing bracket. Service or replace the fan as required.
GROUND STUD
WINGNUT
SECURING
TAB
FIGURE 14
WIRES
6. Reinstall the blower assembly
making sure the blower bracket is
seated under the securing tab.
FIGURE 14. Reattach the wire con-
nectors. FIGURE 15.
7. Replace the gasket on the ac-
cess door. To replace the access
panel, reverse Step 3 .
8. Replace the bricks into the fire-
box. Reinstall the door.
FIGURE 15
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
10
FINISHING
SIZES
1100/1100C 1101/1100L
1400
4-#1
2-#4
1401/1400L
1900
4-#7*
2-#2
4-#1
2-#4
4-#1
2-#4
4-#1
2-#4
#1. 1-1/4" x 4"-1/2 x 9"
#2. 1-1/4" x 3" x 9"
BACK
SIDES
#3. 1-1/4" x 4-1/2" x 4-1/2"
#4. 1-1/4" x 4-1/2" x 9"
#5. 1-1/4" x 2-1/2" x 4-1/2"
#6. 1-1/4" x 1-1/2" x 4-1/2"
#7. 1-1/4" x 4-1/2" x 9"
* (light weight)
#8. 1-1/4" x 2-1/4" x 9"
#9. 1-1/4" x 2-1/4" x 6-1/8"
#10. Fibre baffle - 9” x 1” x 12”
8-#1
2-#3
8-#1
2-#3
12-#1
12-#1
12-#7*
2-#3
2-#4
(notched)
TOP
2-#102-#10
2-#11
2-#11
2-#12
3-#1
2-#2
1-#5
1-#6
4-#1
2-#2
5-#1
2-#2
1-#5
1-#6
6-#1
2-#2
7-#7*
2-#2
1-#5
1-#6
FLOOR
FRONT
2-#2
1-#8
1-#9
2-#2
1-#8
1-#9
2-#2
1-#8
1-#9
2-#2
1-#8
1-#9
2-#2
1-#8
1-#9
#11. Fibre baffle - 9” x 1” x 16 1/2”
#12. Fibre baffle - 9” x 1” x 19 1/2”
10
10
10
10
MODEL 1100/1100C - FIGURE 17
MODEL 1101/1100L - FIGURE 18
11
11
11
11
MODEL 1401/1400L - FIGURE 20
MODEL 1400 - FIGURE 19
12
12
AREA CIRCLED ON EACH FIGURE INDICATES
THE BRICK RETAINER DETAIL
MODEL 1900 - FIGURE 21
BRICK RETAINER DETAIL - TYPICAL
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
11
BRICK and BAFFLE INSTALLATION
With stove and chimney installation completed, move
the bricks into place by working as illustrated for your
unit on page 10.
1. Install two or three courses of brick on both sides of
the unit. Install two courses on the back wall. Install the
final course of bricks on the back wall. These bricks
are held in place by a brick retainer. Before installing
the bricks, loosen the screw holding the retainer and
ensure that it has been moved forward. Insert the final
two bricks behind the retainer and while still holding
the bricks in place, slide the retainer snugly into place.
Retighten the screw.
2. Carefully pivot fibre baffle up on to the top of the
side brick. Slide it over onto the flange of the manifold.
Ensure that the top baffles are pushed all the way to
the rear of the firebox, leaving a minimum of a 1 inch
gap along the front. This will allow the flue gases to
escape the firebox.
operating
instructions
WARNING: Remove all sources of gasoline
or other flammable vapours and liquids in the
vicinity of this or other appliances before
lighting.Your Napoleon EPA listed product is a Hi-Tech
unit, designed with the most advanced technology. The
unit is extremely airtight. It has an exclusive direct out-
side air supply (optional kit), a safety feature designed
to prevent spillage, and to keep your house free of car-
bon monoxide, in case of a downdrafting chimney or an
internal negative pressure.
The first fire(s) in your unit will be difficult to get going
and keep going with little amount of heat being gener-
ated. This is a result of the moisture being driven out of
the fire brick. Allow 30 to 40 hours of hot fires ( tem-
peratures in excess of 500°F - 600°F) before your unit
will perform normally. During the break-in period (the
first 2 or 3 fires) create only small, hot fires using kin-
dling; this will allow the firebrick to cure. Do not be
alarmed if small hairline cracks develop in the firebrick.
This is a normal occurrence and does not pose a safety
hazard. The paint may also smell a little for the first few
fires as it cures and you may wish to open a door or
window to alleviate the smell.
3. Install the bottom bricks, working from the back of
the unit.
4. Install the 2 bricks along the front.
ORNAMENTAL TRIVET INSTALLATION
Insert the ornamental trivet into the space on the stove
top.
TRIVET
FIGURE 22
To start, a brisk fire is required. Place loosely crum-
pled paper on the floor of the stove and cover with dry
kindling. Open the draft control fully by pulling the lever
forward. Light the paper and leave the door slightly ajar
(one inch) until all kindling is burning. To maintain a
brisk fire, a hot coal bed must be established and main-
tained.
DOOR and HANDLES INSTALLATION
Hang the door using the hinge pins supplied. Twist the
large wire handle over the end of the handle rod.
Twist the smaller wire
handle over the end of
the air damper rod be-
low the door. Install
ash pan pull handle
using screws and
washers.
Slowly add larger wood (2x4 size pieces). Lay the pieces
lengthwise from side to side in the hot coal bed with a
shallow trench between, so that the primary air can flow
directly into this trench and ignite the fuel above. When
the fire seems to be at its peak, medium sized logs
may be added. Once these logs have caught fire, care-
fully close the door. (Closing the door too quickly after
refueling will reduce the firebox temperature and result
in an unsatisfactory burn.) Remember it is more effi-
cient to burn medium sized wood, briskly, and refuel
frequently than to load the fireplace with large logs that
result in a smouldering, inefficient fire and dirty glass.
As soon as the door is closed, you will observe a change
in the flame pattern. The flames will get smaller and lazier
because less oxygen is getting into the combustion cham-
ber. The flames, however, are more efficient. The flames
will remain lazy but become larger again as soon as the
firebricks have been heated thoroughly and the chimney
becomes heated and provides a good draft. At this point,
the roaring fire that you see when the door is opened is
wastefully drawing heated room air up the chimney -- cer-
tainly not desirable. Always operate with the door fully
closed once the medium sized logs have caught fire.
FIGURE
See FIGURE 26.
PEDESTAL TRIM INSTALLATION
Ensure that the pedestal sur-
faces are clean and dry; peel
the protective backing from
the trim adhesive. Insert one
end of the brass trim into one
of the slots located in the
pedestal and pressing firmly,
proceed around to the other
slot. Cut trim to size. Attach
the rear knockout plate (lo-
cated inside the ash pan for
shipping purposes).
FIGURE 24
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
12
You can now add larger pieces of wood and operate the
stove normally. Once the stove/insert is entirely hot, it
will burn very efficiently with little smoke from the chim-
ney. There will be a bed of orange coals in the firebox
and secondary flames flickering just below the top fire-
brick. You can safely fill the firebox with wood to the top
of the door and will get best burns if you keep the stove
pipe temperatures between 250 degrees Fahrenheit (120
degrees Celsius) and 450 degrees Fahrenheit (270 de-
grees Celsius). A surface thermometer will help regu-
late this.
FIRE EXTINGUISHERS / SMOKE DETECTORS
All homes with a solid fuel burning fireplace should
have at least one fire extinguisher in a central loca-
tion known to all, and at least one smoke detector in
the room containing the fireplace. If it sounds an
alarm, correct the cause but do not deactivate or
relocate the smoke detector.
FUEL LOADING AND BURN CYCLE
When loading the stove, ensure that the two upper
courses of firebrick are not lifted up and off their
ledge.
For maximum efficiency, when the stove is thoroughly
hot, load it fully to the top of the door opening and burn at
a medium low setting. Maximum heat for minium fuel (op-
timum burn) occurs when the stove top temperature be-
Without a stove thermometer, you are working
blindly and have no idea of how the stove is oper-
ating! A stove thermometer offers a guide to per-
formance.
Can't get the fire going? Use more kindling and paper. neath the trivet is between 500°F (260°C) and 600°F
Assuming the chimney and vent are sized correctly and (315°C). The bricks will be nearly all white and the glass
there is sufficient combustion air, the lack of sufficiently
dry quantities of small kindling is the problem. Thumb
size is a good gauge for small kindling diameter.
Can't get heat out of the unit? One of two things may
have happened. The stove/insert door may have been
closed prematurely and the unit itself has not reached
mostly clear. The whiteness of the bricks and the clean-
ness of the glass are good indicators of your operating
efficiency. Not enough heat is produced when only one
or two pieces of wood are burned or the wood may not
burn completely. A minimum of three pieces are needed
to encase a bed of coals that sustains the fire.
optimum temperature. Reopen the door and/or draft Loosely stacked wood burns quicker than a tightly packed
control to re-establish a brisk fire. The other problem load. Wood burns in cycles rather than giving a steady
may have been wet wood. The typical symptom is siz- output of heat. It is best to plan these cycles around your
zling wood and moisture being driven from the wood.
household routine so that only enough coals are left to
start the next load. In the evening, load your stove, at
least, a half-hour before bed to ensure a good fire, hot
enough to close the draft control for an overnight burn.
Burn only dry seasoned wood.
It produces more heat and less soot or creosote. Do not
burn ocean beach wood. Its salt content can produce a
metal eating acid. When refueling open the door slowly to
prevent smoke spillage. Use a pair of long gloves (barbe-
cue gloves) when feeding the fire. Because these stoves
burn at the front, they are clean and efficient, but they are
also very hot and gloves are useful. Keep a small steel
shovel nearby to use as a poker and to remove ashes. Do
not store the wood within 3 feet (1m) of the stove.
ACHIEVING PROPER DRAFT
Draft is the force which
moves air from the firebox
up through the chimney.
The amount of draft in your
chimney depends on the
length and diameter of
chimney, local geography,
nearby obstructions and
other factors. Adjusting the
ASH FENDER
FIGURE 25
draft control regulates the temperature. The draft can
be adjusted from a low burn rate with the handle in fully,
to a fast burn rate with the handle fully out.
Inadequate draft may cause back-puffing into the room
through the stove/insert and chimney connector points
and may cause plugging of the chimney. Too much
draft may cause an excessive temperature in the stove,
glowing red stove parts or chimney connectors or an
uncontrollable burn which can lead to a chimney fire or
permanent damage to the unit.
FLASH FIRE
A flash fire is a small fire burned quickly when you don't
need much heat. After your kindling has "caught", load at
least 3 pieces of wood, stacked loosely. Burn with the
draft control fully open or closed only slightly.
EXTENDED FIRE
Load your larger pieces of wood compactly, packed close
enough to prevent the flames from penetrating it completely.
After approximately 30 minutes, depending on the size of
the load, close the draft control completely making sure
that the fire is not extinguished.
Do not operate your stove/insert for longer than 30 min-
utes with the draft control on "HIGH" (fully open).
ASH WELL
COVER
* NOTE: 1100C ash pan is
not equipped with a cover
or rear folding handle.
TO OPEN:
PULL AND
ROTATE
TO CLOSE:
ROTATE
FIGURE 26
REAR
FOLDING
PULL HANDLE
W415-0360 / 11.05.02
HANDLE
Download from Www.Somanuals.com. All Manuals Search And Download.
maintenance 13
Check your chimney and chimney connector for creosote and
soot buildup weekly until a safe frequency for cleaning is es-
tablished. If accumulation is excessive, disconnect the stove
and clean both the chimney and the stove. You may want to
call a professional chimney sweep to clean them. Both have
to be cleaned at least once a year or as often as necessary.
Remove fibre baffles and clean above them once a year. Re-
place any broken bricks.
CREOSOTE FORMATION AND REMOVAL
When wood is burned slowly, it produces tar and other
organic vapours which combine with expelled moisture to
form creosote. These vapours condense in the relatively
cooler chimney flue of a slow burning fire and when ig-
nited, make an extremely hot fire. So, the smoke pipe and
chimney should be inspected monthly during the heating
season to determine if a buildup has occurred. If creosote
has accumulated it should be removed to reduce the risk
of a chimney fire.
DO NOT OVERFIRE THE STOVE!
Overfiring can occur by:
a) burning large amounts of smaller wood pieces such as
furniture scraps, skids or treated wood;
b) vigorously burning large loads of wood with the draft
control on "HIGH" (fully open) for long periods of time
(one or two hours).
SMOKING
A properly installed Napoleon unit should not smoke. If
yours does, check the following: Has the chimney had
time to get hot? Is the smoke passage blocked anywhere
in the stove, chimney connector or chimney? Is the room
too airtight and the air intake not connected to the out-
side? Try with a window partly open. Is the smoke flow
impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a
cold outside chimney, too large a diameter of a chim-
ney, too short a chimney, or a chimney too close to trees
or a higher roof? Has a direct flue connection been used
rather than a chimney liner continuous from cap to fire-
place flue collar.
RUNAWAY OR CHIMNEY FIRE
ASH REMOVAL PROCEDURES
Allow the ashes in your firebox to accumulate to a depth
of two or three inches; they tend to burn themselves up.
When the fire has burned down and cooled, remove any
excess ashes but leave an ash bed approximately 1 inch
deep on the firebox bottom to help maintain a hot char-
coal bed.
Runaway fires can be the result of three major factors:
1. Using incorrect fuel, or small fuel pieces which wood
normally be used as kindling.
2. Leaving the door ajar too long and creating extreme
temperatures as the air rushes in the open door.
3. Burning your stove with the ash dump door open.
SOLUTIONS:
1. Do not burn treated or processed wood, coal,charcoal,
coloured paper or cardboard.
2. Be careful not to over-fire the unit by leaving the door
open too long after initial start-up. A thermometer on
the chimney connector and/or stove top helps.
3. Always operate the stove with the ash well in a closed
position.
UNITS WITH ASHPAN:
To use your ash pan, pull the ash dump handle forward
(FIGURE 26), rotate approximately 90° counterclockwise
to the open position. Rake the excess ashes into the ash
pan. Close the ash well.
NEVER OPERATE YOUR STOVE WITH THE ASH
WELL IN AN OPEN POSITION.
This creates a fire hazard that may result in a house/chim-
ney fire, internal damage to the stove or discoloration to
the gold plated door (plated finishes are not covered by
WHAT TO DO IF A RUNAWAY OR
CHIMNEY FIRE STARTS
the warranty). To ensure that the ash well is fully closed, 1. Close the door and draft fully.
2. Call local fire department.
allow the door to snap shut, dislodging anything that may
be stuck at the opening. Flip the cover up onto the ash
pan when transporting the ashes to a closed container
with a tight fitting lid for storage. Carry the ash pan using
the front and back handles. * FIGURE 26.
UNITS WITHOUT ASH PAN:
3. Examine flue-pipes, chimney, attic, and roof of the
house, to see if any part has become hot enough to
catch fire. If necessary spray with a fire extinguisher
or water from a garden hose.
4. Do not operate the stove again until you are certain
thechimney and its lining have not been damaged.
Since these models have no ash pan, shovel some ashes
out through the door into a metal container with a tight
fitting lid. Leave an ash bed approximately 1 inch deep on
the firebox bottom to help maintain a hot charcoal bed.Keep
the closed container on a noncombustible floor or ground,
well away from all combustible materials. The ashes should
be retained in the closed container until all cinders have
thoroughly cooled. Cold wood ashes can be used on the
garden or in the compost.
GASKETREPLACEMENT
At the end of each burning season inspect the shield
and gasket below the manifold for warping or deteriora-
tion. Replace if necessary. Both are held to the mani-
fold with machine screws. The shield and the 1/8" fibre
cloth gasket are available from your Wolf Steel Ltd.
dealer. See FIGURE 27. At this time also check that
the door gasket is not worn or loose. Replace with 3/8"
high density fiberglass rope if necessary.
DOOR REMOVAL (1100C ONLY)
MANIFOLD
1. Remove cast top.
2. Pull pin from top door hinge. It is important to hold the
door while removing the pin. Pivot the door to clear the
top door hinge. Lift the door off of the lower pin. Do not
SHIELD
GASKET
FIGURE 27
pivot the door any further than necessary.
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
14
WOOD PILE MAINTENANCE
Burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly
cut wood contains about 50% moisture while after proper seasoning only about 20% of the water remains. As wood is
burned, this water boils off consuming energy that should be used in heating. The wetter the wood, the less heat is
given off and the more creosote is produced.
Both hardwood and softwood burn equally well in this stove but hardwood is denser, will weigh more per cord and
burn a little slower and longer. Firewood should be split, stacked in a manner that air can get to all parts of it and
covered in early spring to be ready for burning that fall. Dry firewood has cracks in the end grain. Cut the wood so that
it will fit horizontally, front to back, making for easier loading and less of a likelihood that the wood will roll onto the
glass. Ideal lengths of wood are approximately 12" for EPA 1100, 1100C, 1100L and 1101, 16 1/2" for EPA 1400,
1400L and 1401, and 21" for EPA 1900.
DO'S
DON'TS
1. Build a hot fire
1. Take ash out immediately. Let it accumulate to a
depth of at least one inch. A good ash layer pro
vides for a longer lasting and better burning fire.
2. Burn wet wood.
2. Use only dry wood.
3. Several pieces of medium sized wood are
better than a few big pieces.
4. Clean chimney regularly.
5. Refuel frequently using medium sized
wood.
3. Close the door too soon or damper down too quickly.
4. Burn one large log rather than two or three smaller,
more reasonably sized logs.
6. "Fine Tune" the air settings for optimum
performance.
5. Burn at continually "low setting", if glass door is
constantly blackened. This means the firebox tem
perature is too low.
Wolf Steel Fireplace Service History
This fireplace must be serviced annually depending on usage.
Service Performed /
Special Concerns
Service Technician
Name
Date
Dealer Name
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
15
ORDERING PROCEDURES
Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all
parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give
the following information:
1. Model & Serial Number of fireplace
2. Installation date
3. Part Number
4. Description of part
5. Finish
REPLACEMENT PARTS
ACCESSORIES / OPTIONS
#
PART NO. DESCRIPTION
#
PART NO. DESCRIPTION
1
1
2
3
4
5
6
7
W325-0002
W325-0007
W090-0001
W090-0002
W090-0003
W090-0004
W090-0005
W090-0016
W090-0017
W090-0015
W090-0018
W090-0019
W018-0077
W018-0078
W018-0079
W715-0073
W160-0014
W010-0347
W570-0007
GZ551
SPRING HANDLE - SMALL
SPRING HANDLE - LARGE
BRICK - # 1
BRICK - # 2
BRICK - # 3 - MODELS 1100, 1100C, 1100L, 1101, 1900
BRICK - # 4 LEFT
BRICK - # 4 RIGHT
BRICK - # 5 - MODELS 1100, 1100C, 1400, 1900
BRICK - # 6 - MODELS 1100, 1100C, 1400, 1900
BRICK - # 7
BRICK - # 8
BRICK - # 9
# 10 FIBRE BAFFLE - MODEL 1100, 1100C, 1100L, 1101
# 11 FIBRE BAFFLE - MODEL 1400, 1400L, 1401
# 12 FIBRE BAFFLE - MODEL 1900
ASH FENDER TRIM C/W CORNER BRACKETS
SPRING CLIP FOR ASH FENDER
39
39
40
41
42
43
43
43
H222G
H222
GOLD PLATED DOOR
BLACK DOOR
DOOR GLASS ONLY
DOOR GASKET
W300-0017
W020-0043
W020-0050
GS200-G
GS-330G
GS-530G
GLASS GASKET
ORNAMENTAL TRIVET - GOLD PLATED - MODEL 1100
GOLD PLATED TRIVET - MODELS 1400, 1900
ORNAMENTAL TRIVET
8
9
- GOLD PLATED - MODELS 1400, 1900
VARIABLE SPEED BLOWER
- MODELS 1100, 1100L, 1400, 1400L, 1900
44
EP62-1
10
11
12
13
14
15
16
17
18
19
20
21
45
46
47
W500-0064
111KT
W470-0002
FRESH AIR COVER PLATE - MODELS 1100, 1400, 1900
OUTSIDE AIR KIT - MODELS 1100, 1400, 1900
ENAMEL TOUCH UP & BRUSH (SPECIFY COLOUR)
- MODELS 1100, 1400, 1401, 1900
48
49
49
50
51
52
EPA335KT
EPI-RK
EPA-RK
AK-1
AK-2
CISK*
LOW CLEARANCE FLUE CONNECTOR - MODEL 1401
SOLID BRASS RAILING KIT - MODEL 1401
SOLID BRASS RAILING KIT - MODELS 1100L, 1400L
ADAPTER KIT FOR CISK - MODEL 1101
ADAPTER KIT FOR CISK-A - MODEL 1401
CAST IRON SURROUND KIT, PAINTED BLACK
AIRWASH GASKET & SHIELD
SCREWS for MANIFOLD & SHIELD
REPLACEMENT FAN
BLACK TRIVET - MODEL 1100
W200-0077
EP-11MS
MANIFOLD GASKET & SHIELD
52 CISK*A
CAST IRON SURROUND KIT, ENAMEL PORCELAIN
10" FLASHING KIT C/W BULL NOSE TRIM - MODEL 1101
AIR CIRCULATION CHAMBER LOUVRES (BLACK)
- MODELS 1100L, 1400L
- MODELS 1100, 1100C, 1100L, 1101
COMPLETE BRICK SET - MODEL 1100, 1100C
COMPLETE BRICK SET - MODEL 1400
COMPLETE BRICK SET - MODELS 1401, 1400L
COMPLETE BRICK SET - MODEL 1900
COMPLETE BRICK SET - MODELS 1101, 1100L
MANIFOLD GASKET & SHIELD
- MODELS 1400, 1401, 1400L
HEAT SENSOR - MODELS 1101, 1401
BLACK TRIVET - MODELS 1400 & 1900
MANIFOLD GASKET & SHIELD - MODEL 1900
BLACK CANOPY LOUVRES - MODELS 1100, 1400, 1900
GOLD PLATED CANOPY LOUVRES
- MODELS 1100, 1400, 1900
53
54
EI-900K10
EPLK
22
22
22
22
22
23
W580-0001
W580-0002
W580-0005
W580-0003
W580-0006
EP-14MS
54
EPLG
AIR CIRCULATION CHAMBER LOUVRES (GOLD)
- MODELS 1100L, 1400L
55
56
W320-0011
EP36
BLOWER GUARD - MODELS 1100L, 1400L
THERMOSTATIC SENSOR CONTROL KIT
- MODELS 1100, 1100L, 1400, 1400L, 1900
TRADITIONAL STEEL LEGS (BLACK)
- MODEL 1100L, 1400L
24
25
26
27
27
W690-0002
GS-330K
EP-19MS
CL28
57
200K
58
58
202CK
202CG
ORNAMENTAL CAST IRON LEGS - MODEL 1100L, 1400L
ORNAMENTAL CAST IRON LEGS (GOLD PLATED)
- MODEL 1100L, 1400L
CL28G
28
29
W010-0349
KB-35
PEDESTAL TRIM - MODELS 1100, 1400, 1900
VARIABLE SPEED CONTROL C/W KNOB
- MODELS 1100, 1100C, 1100L, 1400, 1401, 1400L,1900
VARIABLE SPEED CONTROL C/W KNOB - MODEL 1101
ASH PAN (NO FRONT PLATE) - MODELS 1100, 1400, 1900
ASH PAN HANDLE - MODELS 1100, 1400, 1900
5/16" PLUG - MODELS 1100L, 1400L, 1401
CAST TOP
*FOR AVAILABLE PORCELAIN COLOURS,
ADD THESE LETTERS TO THE BASE PART NUMBER:
GREEN
BROWN
BLACK
BLUE
-
-
-
-
F
N
K
B
30
31
32
33
34
KB-36
W010-0243
W325-0011
W510-0001
W135-0143*
35
36
37
38
W135-0144*
W135-0145*
W135-0146*
W135-0147*
CAST SIDES
CAST ASHLIP
CAST LEG
CAST DOOR
*FOR AVAILABLE PORCELAIN COLOURS,
ADD THESE LETTERS TO THE BASE PART NUMBER:
GREEN
BROWN
BLACK
-
-
-
F
N
K
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
16
35
39
34
1
38
17
35
37
36
15
19
43
32
28
49
44
33
31
55
24
1
29
48
40
58
57
51
52
50
53
W415-0360 / 11.05.02
Download from Www.Somanuals.com. All Manuals Search And Download.
|