Introduction  
These System Release Notes provide you with the latest up-to-date information  
about your system. These notes also provide additional valuable information  
about your server that was not included in the printed documentation.  
The System Release Notes are written for knowledgeable users, trained  
customer engineers, system analysts, service center personnel, and dealers.  
Please read these System Release Notes in their entirety before starting.  
CONTENTS  
General Notes  
General Comments  
Advisories  
System Start-Up..................................................................................................................................... 3  
Memory Test Acceleration ................................................................................................................ 3  
Power Button Override...................................................................................................................... 3  
Setting Up the Software ......................................................................................................................... 4  
Setting Up Windows NT Enterprise Edition ..................................................................................... 4  
HAL Installation.............................................................................................................................. 13  
Registry Update............................................................................................................................... 13  
System Hardware................................................................................................................................. 13  
Interlocks ......................................................................................................................................... 13  
Processor Serial Number ................................................................................................................. 13  
Hot Plug PCI.................................................................................................................................... 14  
ExpressBuilder..................................................................................................................................... 14  
Documentation Errata  
Errata to Express5800 HV8600 User's Guide.................................................................................. 15  
NEC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Notes  
These Release Notes about the server system cover the following topics:  
! General Comments  
! Advisories  
! Documentation Errata.  
General Comments  
The following general comments apply to this server system:  
! Version of the Network Operating System tested and recommended is:  
Windows NT® 4.0 Server Enterprise Edition with Service Pack 4  
Advisories  
This section contains advisories on System Start-Up, Setting Up the Software,  
System Hardware, and EXPRESSBUILDER.  
System Start-UP  
When turning on your system for the first time, you must prepare the system for  
use. When the system is turned on or restarted a short program in ROM starts  
the process of loading programs into memory and then executing these  
programs. These start-up programs perform diagnostic tests that check major  
hardware components, such as memory and interface circuits. It compares the  
hardware it finds with parameters last saved by the Setup utility. This process is  
the Power-On Self-Test (POST).  
Memory Test Acceleration  
To accelerate the memory test during POST press Ctrl+Alt+T.  
Power Button Override  
The system power button does not respond immediately during certain phases in  
POST. However, the power button will respond if it is held down for at least 4  
seconds. The system should power down on the 5th second.  
Server HV8600 System Release Notes 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting UP the Software  
Software setup for the most part is automatic (approximately 15 minutes) and  
requires only that you enter name and organization, registration information,  
internet address, and server parameters. The setup procedures are designed to  
get your server up and running as quickly as possible. The software is  
autoloading, requiring minimal intervention on your part. The following  
sections include the procedures for setting up your server with Windows NT  
Enterprise Edition.  
Setting Up Windows NT Enterprise Edition  
The Windows NT software is preloaded on your server and is ready for setup.  
The Windows NT setup procedures are as follows:  
Before beginning these procedures, there is certain requested information that  
you will need in order to successfully complete setup. This requested  
information can be recorded in advance on the following "Getting Started  
Worksheet" for use during setup.  
Item Information Required  
Enter Your Information Here  
1
2
3
Name of NT Server Administrator  
Organization Name the server will be licensed to  
OEM License number for MS NT Server Software  
Found on the Certificate of License in the documentation pack  
included with your server  
4
5
6
7
8
Name that you assign to the server  
IP address assigned to the server’s Ethernet Interface Card  
Subnet Mask for the server’s Ethernet Interface Card  
Default Gateway IP address for server’s Ethernet Interface Card  
IP address of DNS system to be used with the server. (If you  
have a DNS system within your local area or wide area network,  
you may want to use that system.)  
9
If you use WINS in your current network, you need the Primary  
and Secondary WINS IP addresses.  
Note: If you make a mistake during these setup  
procedures and you can't return to a previous selection, you  
must reboot the server immediately.  
1. Power up your server (see your Server’s “Getting Started” sheet for  
procedures).  
2. The “Windows NT 4.0 Server” screen with Packard Bell NEC in the upper  
left-hand side of the screen is displayed. A “Windows NT Setup: setup is  
initializing.” message momentarily appears on the screen.  
4 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. At the Microsoft “Software License Agreement” dialog box, read and accept  
the Microsoft license agreement by clicking I Agree.  
4. At the “Name and Organization” dialog box, enter your name and  
organization. Click Next when done.  
5. At the “Registration” dialog box, enter the MS Windows NT License  
Number. The number is found on the Certificate of Authenticity. Click Next  
when done.  
Server HV8600 System Release Notes 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. At the “Computer Name” dialog box, enter the server name that is to be used  
with this server. Click Next when done.  
Note: Once you select the server type and click Next in  
step 7, you cannot change the server type.  
7. At the “Server Type” dialog box, select one of the following: Primary  
Domain Controller, Backup Domain Controller, or Stand-Alone Server.  
Click Next after selecting the server type.  
6 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. At the “Windows NT Setup” dialog box, click Next to start installation of  
Windows NT Networking.  
9. You’ll receive two error messages from “Unattended Setup.”  
!
Click OK at the “Error - Unattended Setup” dialog box. You’ll enter the  
IP address information in step 10.  
!
Click OK at the “Error - Unattended Setup” dialog box.” You’ll enter  
the Subnet information in step 10.  
Server HV8600 System Release Notes 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10.At the “Microsoft TCP/IP Properties” dialog box, enter the IP address and  
the Subnet Mask value of the Server’s Ethernet interface card.  
! Enter the static IP address of your Ethernet adapter in the “IP Address:”  
field.  
! Enter your mask value in the “Subnet Mask” field.  
! Enter the default gateway value.  
! If you have a DNS server(s), define the local DNS address now by  
selecting the “DNS” tab and entering the IP address(es) of your DNS  
domain(s) in the appropriate field(s).  
! Select the “WINS Address” tab. Disable “DNS for WINS resolution” and  
“LM Hosts Lookup.”  
! If you use WINS in your wide area or local area network, you should  
specify the IP address(es) of your WINS server(s).  
! When done, click Apply and click OK.  
8 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11.At the “Date/Time Properties” screen, select the proper time zone and  
confirm/correct the proper date and time. Click Close when done.  
!
This portion of the installation installs files, performs some processing,  
and takes several minutes.  
Note: Please read the “Thank you for purchasing a  
NEC server preinstalled with Windows NT” screen. Note any  
recommendations that may apply to your specific installation  
for additional configuration considerations.  
! At the "Thank you for purchasing a NEC server pre installed with  
Windows NT” screen, click Next to continue…  
!
NT Setup sets security on system files and continues to process the  
installation.  
Server HV8600 System Release Notes 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12.At the "Windows NT Server Setup" dialog box, click "YES" to view the log  
file. This screen is for information only and always appears even if no errors  
occur, so that the log file can be viewed. The log file shows the current size  
of the Pagefile.  
13.The "System Setup Log - (C:\WINNT\Setuplog.txt) dialog box opens. The  
amount of information in this dialog box will vary depending on your  
system. In this dialog box you can view the current size of the Pagefile. The  
size of the Pagefile, which is a virtual memory file, varies according to the  
amount of physical memory configured in your system.  
The "C:\WINNT\setuplog.txt" file is where the Windows NT software  
failures are stored.  
Note: After the initial software setup it is recommended  
that you change the size of the Pagefile specifically for your  
system.  
10 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14.At the “Windows NT Setup” dialog box showing that “Windows NT 4.00  
has been installed successfully,” click Restart Computer.  
!
!
After about 30 seconds, the system automatically loads Windows NT  
Server.  
You now have the following applications installed on your server:  
Windows NT Server 4.0 with any updated storage, network, and  
video drivers required for this server system  
Windows NT Service Pack 4  
Microsoft IE 4.01.  
15.Press Ctrl Alt Del to log on to Windows NT Server.  
!
At the Log On Window, press Enter to log on as the Administrator. The  
Windows NT desktop opens.  
Note: At this point there is no Administrator password  
set on your system. Following completion of the installation  
process, refer to the Microsoft Windows NT Servers Books  
Online for information on adding/changing passwords.  
Books Online are on your Windows NT Server CD.  
! At the " Welcome to the Microsoft Windows NT Server, Enterprise  
Edition Installer" dialog box, select "Continue" or "Exit" as follows:  
Click "Continue" to allow optional Windows NT Enterprise Edition  
components to be selected.  
Click "Exit" to return to the Windows NT desktop screen.  
Server HV8600 System Release Notes 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
! At the "Select the Components To Install" dialog box, select the optional  
Windows NT Enterprise Edition components you want to be installed,  
then select " Start Installation." Otherwise, "Exit".  
Click on "Start Installation" to install the optional Windows NT  
Enterprise Edition components selected.  
Click on "Exit" to return to the Windows NT desktop screen.  
12 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAL Installation  
When installing Windows NT on the HV8600 system, it is necessary to use the  
HAL software included with your system.  
Please refer to the NOS Guide included in you EXPRESSBUILDER CD for  
installation instructions.  
Registry Update  
When installing Windows NT on the HV8600 system, it is necessary to update  
the Windows NT registry using the Registry Update diskette included with the  
EXPRESSBUILDER CD provided with your system.  
Please refer to the NOS Configuration Guide included in your EXPRESSBUILDER  
CD for installation instructions.  
System Hardware  
Interlocks  
The top and side panels of your system have interlocks. Removal of these panels  
while the system is running results in DC power being cut off to the system. It is  
strongly recommended that the system be fully shutdown and AC cables  
removed prior to servicing the system.  
Processor Serial Number  
The IntelPentium® III Xeonprocessor has a new feature called the  
"Processor Serial Number." This feature is disabled by default in your system  
BIOS. In order to turn on this feature, enter the BIOS Setup Utility by pressing  
F2 during POST, the Main Menu is displayed. At the top of the Main Menu  
select "Advanced Menu." Under "BIOS Setup Configuration, Advanced,  
Security, and System Hardware" find item "Processor Serial Number" and  
change the default from Disable to Enable.  
Please refer to "Configuring Your System" in your User's Guide, included in  
your EXPRESSBUILDER CD for detailed procedures on how to enable the  
"Processor Serial Number."  
Server HV8600 System Release Notes 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot Plug PCI  
The Hot Plug PCI feature of the HV8600 is active only when an operating  
system that includes Hot Plug PCI support is available.  
When the Hot Plug PCI feature is not active:  
! Do not attempt to replace PCI option cards while the system is running.  
! The Hot Plug PCI access door is secured preventing access to the Hot  
Plug PCI option board area.  
! The system must be powered-off in order to replace PCI option cards. In  
order to access the Hot Plug PCI option board area the entire top panel  
must be removed.  
ExpressBuilder  
The following advisory applies when using EXPRESSBUILDER Version 2.5.  
! If you already have an operating system installed when creating a  
maintenance partition, EXPRESSBUILDER will warn you of the existing  
partition. If you want to preserve the installed operating system, do not  
create the maintenance partition or the existing operating system will be  
overlaid by the maintenance partition.  
14 Server HV8600 System Release Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Documentation Errata  
Please note the following changes to the Express5800 HV8600 User’s Guide.  
Errata to Express5800 HV8600 User's Guide  
The following changes apply to the Express5800 HV8600 User’s Guide  
(456-01505-000).  
Page 3-7 Table 3-1 BIOS Setup Configurations, Advanced Menu. Under  
column heading "Normal Setting or Display Only" for "DIMM Error Pause"  
change the word "Enabled" to "Disabled".  
Page 3-8 Table 3-1 BIOS Setup Configurations, Advanced Menu. Under  
column heading "Menu Parameter Name" delete "L3 Cache Error Pause" and  
under column heading "Normal Setting or Display Only" delete "Enabled".  
Page 3-8 Table 3-1 BIOS Setup Configurations, Advanced Menu. Under  
column heading "Normal Setting or Display Only" for "Parallel Mode:" change  
the word "ECP" to "Bi-Directional".  
Page 3-8 Table 3-1 BIOS Setup Configurations, Advanced Menu. Under  
column heading "Menu Parameter Name" delete "DMA Channel:" and under  
column heading "Normal Setting or Display Only" delete "DMA 3".  
Page 3-9 Table 3-1 BIOS Setup Configurations, Advanced, Security, and  
System Hardware Menus. Under column heading "Normal Setting or Display  
Only" for "PCI Bus#1 Parity Error, PCI Bus#2 Parity Error, and PCI Bus#3  
Parity Error" change the words "Disabled" to "Enabled".  
Page 3-9 Table 3-1 BIOS Setup Configurations, Advanced, Security, and  
System Hardware Menus. Under column heading "Normal Setting or Display  
Only" for "Numlock" change the word "Auto" to "On".  
Page 3-10 Table 3-1 BIOS Setup Configurations, System Hardware Menu  
and Boot Menu. Under column heading "Normal Setting or Display Only" for  
"Upper Limit" change the number "53" to "45".  
Page 3-10 Table 3-1 BIOS Setup Configurations, System Hardware Menu  
and Boot Menu. Under column heading "Normal Setting or Display Only" for  
"Lower Limit" change the number "5" to "4".  
Server HV8600 System Release Notes 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Portable Generator DCA 45SSIU3 User Manual
New Holland Lawn Mower H7150 User Manual
NuTone Ventilation Hood RF 49NR User Manual
Omnimount Indoor Furnishings RSVS5U User Manual
Onkyo Car Satellite TV System CR 305X User Manual
Opticon Network Card 25 WEDGE 04 User Manual
OWI Portable Speaker P5278P User Manual
Palsonic CRT Television 6830GY User Manual
Panasonic IP Phone KX NT300 User Manual
Panasonic Smoke Alarm 1728 User Manual