1. ..Introduction.............................................................................................. 4  
1.1 Key Features................................................................................................ 4  
1.2 Physical Description..................................................................................... 5  
2. ..Startup ...................................................................................................... 7  
2.1 Login into the System................................................................................... 7  
2.2 Network Configuration.................................................................................. 9  
2.2.1 Static IP ..........................................................................................................11  
2.2.2 DHCP ............................................................................................................ 12  
2.2.3 PPPoE........................................................................................................... 13  
2.2.4 LAN Setting ................................................................................................... 14  
2.3 General configuration................................................................................. 16  
2.3.1 PABX Mode (SP5018A only)......................................................................... 16  
2.3.2 SIP Setting .................................................................................................... 18  
3. ..Web Administration ............................................................................... 20  
3.1 General configuration................................................................................. 20  
3.1.1 SIP Advanced Setting.................................................................................... 20  
3.1.2 Payload Type Setting .................................................................................... 22  
3.1.3 Line Setting ................................................................................................... 24  
3.1.4 Qos Setting.................................................................................................... 27  
3.1.5 Speed Dial Setting......................................................................................... 28  
3.1.6 Caller ID Setting ............................................................................................ 30  
3.1.7 CDR Setting .................................................................................................. 32  
3.1.8 Syslog Setting ............................................................................................... 34  
3.2 Advanced Configuration............................................................................. 36  
3.2.1 System setting............................................................................................... 36  
3.2.2 SNTP Setting................................................................................................. 40  
3.2.3 Codec Setting................................................................................................ 41  
3.2.4 Voice Setting ................................................................................................. 42  
3.2.5 Tone Setting .................................................................................................. 44  
3.2.6 Phone Setting................................................................................................ 46  
3.2.7 Digit Manipulation.......................................................................................... 48  
3.2.8 Dial Plan........................................................................................................ 50  
3.3 Management .............................................................................................. 52  
3.3.1 Provision Server............................................................................................ 52  
3.3.2 Save-Reload setting...................................................................................... 53  
3.3.3 Upgrade Firmware......................................................................................... 54  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.4 Reset to Default............................................................................................. 58  
3.3.5 Network Status .............................................................................................. 59  
3.3.6 Version Info. .................................................................................................. 60  
3.3.7 Port Status..................................................................................................... 61  
3.3.8 Password....................................................................................................... 62  
3.4 Rebooting the system................................................................................. 63  
4. ..Operation................................................................................................ 64  
4.1 Peer to Peer mode (FXO to FXS)............................................................... 64  
4.2 Peer to Peer mode (FXS to FXS)............................................................... 68  
5. ..Specification........................................................................................... 72  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Introduction  
Micronet SP5008A / SP5018A / SP5058A are high-capacity SIP Gateway  
Series that provides 8 FXS / 4 FXS + 4 FXO / 8 FXO ports, and suit to build an  
IP-based communication platform with other VoIP devices. They meet enterprise’s  
requirement for functionality (VoIP) upgrade and larger scale implementation by  
interoperating with legacy PABX and IP PBX/Soft-switch.  
To connect with legacy PABX, SP5018A supports PABX Mode for PSTN  
backup. When network or power fails, PSTN lines (FXO) bypass to FXS ports and  
users still can make/receive calls via PSTN lines.  
In addition, SP5008A includes some wonderful PABX features for small  
business. They help operate users on various VoIP applications, such as extension  
calling among 8 FXS ports, inbound/outbound calls via SIP trunk, DID (direct line),  
DOD, prefix routing, operator attendant, etc. Users can easily benefit from the  
ease-to-use device.  
1.1 Key Features  
z
z
z
z
z
z
IETF SIP standards compliant  
Support 1 RJ-45 WAN port and 4 RJ-45 LAN ports  
Support POTS interfaces: 8 FXS / 4 FXS + 4 FXO / 8 FXO ports  
Support single-account registration on FXS ports for representative number  
Support extension calling among FXS ports  
Support rich call features: call hold, call transfer, call forward, hotline, warm line,  
speed dial, anonymous call, P2P call, etc  
z
z
z
Support PSTN prefix routing (SP5018A only)  
Support PABX mode for legacy PABX function upgrade (SP5018A only)  
Support PSTN lifeline – PSTN bypass in case of power or registration failure  
(SP5018A only)  
z
z
Support detection of disconnect tone, polarity reversal, and loop current drop  
(zero voltage) on FXO ports  
Well interoperability with industry-leading IP-PBX/Soft-Switch, such as Alcatel,  
Lucent, Siemens, etc.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 Physical Description  
SP5008A:  
SP5008A Front Panel  
SP5058A  
SP5018A  
SP5058A Front Panel  
SP5018A Front Panel  
LED Indicators  
LED  
Status  
Description  
POWER  
READY  
PROXY  
On / Green  
The Power is on  
Blink / Green  
Blink / Green  
Constant / Green  
Blink / Green  
Booting up for self test  
Gateway reg. fails  
Gateway reg. successes  
WAN  
Transmitting or receiving data /Network  
connection established  
LAN(1-4)  
T(1*)  
Blink / Green  
Transmitting or receiving data /Network  
connection established  
On / Orange  
Off  
Busy / Off-hook  
Available / On-hook  
Busy  
L(1*)  
On / Orange  
Off  
Available  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
1*. SP5008A: FXS = T1 - T8  
SP5018A: FXS = T1 - T4, FXO = L1 - L4  
SP5058A: FXO = L1 - L8  
SP5008A  
SP5008A Rear Panel  
SP5058A  
SP5018A  
SP5058A Rear Panel  
SP5018A Rear Panel  
---------------------------------------------------------------------------------------------------  
RESET  
T1-T8  
Factory default button. Press and hold for 5 seconds to reset  
The RJ-11 FXS port 1-8, connects analog phone sets, trunk line in PABX.  
The RJ-11 FXO port 1-8, connect to PSTN  
L1-L8  
T1/P1-T4/P4  
It is a pair of FXO and FXS connector. The different is that the when power off  
or application is crashed, the FXO and FXS will be connected together  
automatically for local surviving.  
WAN  
RJ-45 port of 10/100M for connecting to modem  
LAN(1-4)  
DC 12V  
RJ-45 port of 10/100M for connecting to PC or hub/switch that connects PCs  
The power socket, input AC 100V~120V; output DC12V.3A  
---------------------------------------------------------------------------------------------------  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.Startup  
2.1 Login into the System  
First of all, connect your computer to MICRONET SP5008A / SP5018A / SP5058A’s  
LAN port by using DHCP. The IP address assign to your computer should be  
192.168.123.x by default. Once you can get the IP address from MICRONET  
SP5008A / SP5018A / SP5058A, you can start the configuration as below.  
Step 1. Connect LAN port to your managing PC. Or, connect the gateway with PC  
by hub/switch.  
Step 2. Launch your web browser with http://192.168.123.123/. Please configure  
IP address of PC with 192.168.123.x. Or set up your PC in DHCP mode to  
get IP address automatically.  
Step 3. The Password screen now appears. Type “root” in the user name field,  
and your password (none by default) in the password field.  
Step 4. You will enter the main page of the web configuration interface after you  
keyed in the username and password correctly (see figure below).  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Network Configuration  
By default, the gateway is in NAT mode (router mode) and can share Internet  
access with PCs. Go to [ Network Configuration / WAN Setting ], and configure  
WAN setting according to actual condition. In default IP type of DHCP client, it  
requests necessary IP information from your ISP automatically.  
-----------------------------------------------------------------------------------------------------  
Note:  
1. Different ISPs require different methods of connecting to the Internet. Please consult your  
ISP to select right IP type (Fixed IP, PPPoE) of WAN.  
2. You can retrieve the IP address of the WAN port by keying #126# on the phone set that is  
connected to the FXS port of the gateway. You will hear an IVR announcing the current IP  
address of the WAN port.  
-----------------------------------------------------------------------------------------------------  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
WAN Setting  
Item  
Description  
Static IP  
DHCP  
PPPoE  
Connected mode  
Select the connection method for  
the WAN port of the  
SP5008A/SP5018A/SP5058A, you  
can choose the following:  
V
V
V
V
V
V
z
z
z
Static IP  
DHCP  
PPPoE  
Current IP Address  
DNS server mode  
Show current IP address  
Select the DNS behavior, you can  
choose the following:  
z
z
Auto  
Manual  
“DNS auto” will retrieve the DNS  
information sent from the DHCP  
server.  
V
V
V
“Manual” will look at the specified  
Primary and Secondary DNS  
address.  
Primary DNS  
address  
Specify the address of the Primary  
DNS.  
V
V
V
V
V
V
Secondary DNS  
address  
Specify the address of the  
Secondary DNS.  
WAN Link Speed  
Select the connection speed for the  
WAN port of the  
SP5008A/SP5018A/SP5058A, you  
can choose the following:  
V
V
V
V
V
z
z
z
Auto  
100M  
10M  
HTTP port for WEB  
management  
Specify the port number for WEB  
management, the allowable range is  
80,1024~65535.  
V
IP address  
Specify the IP address.  
V
V
Subnet mask  
Specify the subnet mask.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
Description  
Static IP  
V
DHCP  
PPPoE  
Default gateway  
Specify the IP address of the default  
gateway.  
Remote access  
restriction  
Restricts/Blocks users connecting to  
the WAN port’s IP remotely, you can  
Enable/Disable this option.  
Specify the username of the PPPoE  
account  
V
V
V
PPPoE userID  
V
V
PPPoE password  
Specify the password associated to  
the PPPoE account above.  
When the remote host (PPPoE)  
fails, the gateway will retry 3 times  
to reconnect, if there is no reply  
from the remote host within 3 tries,  
then the gateway will reboot. You  
can Enable/Disable this option.  
Reboot after remote  
host disconnection  
V
2.2.1 Static IP  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Press the “Reboot” button to apply the changes.  
2.2.2 DHCP  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
-----------------------------------------------------------------------------------------------------  
Note:  
When you are using DHCP in WAN and not connected, please make sure you connect Ethernet  
before use PC to connect to LAN port.  
-----------------------------------------------------------------------------------------------------  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.3 PPPoE  
1. Input PPPoE user ID and password  
2. Press the “Apply” button (at the bottom) after you finish to save changes.  
3. Press the “CANCEL” button (next to the Apply button) to clear the values in  
the page.  
4. Press the “Reboot” button to apply the changes.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.4 LAN Setting  
ITEM  
Description  
LAN IP address  
Specify the IP address of the SP5008A /  
SP5018A / SP5058A LAN port.  
LAN mask address  
DHCP server  
Specify the mask address for SP5008A /  
SP5018A / SP5058A LAN port.  
Enable/Disable DHCP function on the LAN port.  
Once enabled, the LAN ports will function as a  
DHCP server, network devices connected to  
them will be issued with IP addresses.  
When DHCP is enabled, you can specify the IP  
address to start from when assigning to attach  
network devices.  
IP address from  
IP address to  
When DHCP is enabled, you can specify the  
ending IP address assigned to the attached  
network devices.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ITEM  
Description  
Domain Name  
You can specify the domain name that will be  
assigned by the DHCP server to the attached  
network devices. The DHCP server will send  
information on the “server host name” to the  
DHCP client.  
Lease time(sec)  
You can specify the maximum lease time of the  
IP address allocated to the DHCP client.  
Select the DNS behavior, you can choose the  
following:  
DNS server mode  
z
z
Auto  
Manual  
“DNS auto” will retrieve the DNS information sent  
from the DHCP server.  
“Manual” will look at the specified Primary and  
Secondary DNS address.  
Primary DNS address  
Specify the address of the Primary DNS.  
Specify the address of the Secondary DNS.  
Secondary DNS address  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 General configuration  
To make VoIP calls, you will need a SIP account provided by the SIP Proxy you are  
registered with. To configure the relevant SIP settings, please refer to the  
instructions explained below.  
2.3.1 PABX Mode (SP5018A only)  
This quick setting is used for MICRONET SP5018A to operate in PABX connection  
mode between PSTN and traditional PABX. Enable PABX mode for ISP/ITSP  
scenario that forbids SIP call to/from PSTN via the gateway (SP5018A). The call  
scenario will be working as below:  
1. For FXO incoming call, it will route to corresponding FXS directly (1 by 1)  
2. For FXS outgoing call, it will route to VOIP except those prefix set in FXO  
dialing Prefix.  
3. For VOIP incoming call, it will route to FXS based on the called number  
4. When VOIP call is failed to be called out such as register fail or network  
issue, the call will be route to FXO as backup.  
5. When MICRONET SP5008A / SP5018A / SP5058A is malfunction or  
power failure, the all call will be directly bypassed to FXO.  
To enable PABX behavior or not.  
PABX Connection  
SIP Setting  
Please refer to 3.3.2.1  
It is used (Yes) when you only have 1 SIP account and  
would like to be shared for all FXS lines. Please refer to  
Representative Number Only  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.2.1  
When you have multiple SIP accounts for each FXS line,  
please set Representative Number Only to No. Then refer  
to 3.3.2.1 for the detail  
Primary FXS SIP settings  
FXO Dialing Prefix  
When the prefix is set here, the call will be route to FXO  
instead of VOIP.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.2 SIP Setting  
Specify the data of primary proxy : Enable/Disable, IP  
address, Port#, Domain Name, Expire time and MWI TTL.  
The P2P mode will be explained in paragraph Appendix A  
Specify the data of secondary proxy: Enable/Disable, IP  
address, Port#, Domain Name, Expire time and MWI TTL.  
When you enable secondary proxy, it will start to register no  
matter whether primary proxy is registered or not. However, it  
will be used only when primary proxy is not registered or the  
incoming call is coming from it.  
Primary proxy/P2P IP  
Secondary proxy  
Specify the data of Outbound proxy: Enable/Disable, IP  
address and Port#.  
Outbound proxy  
Specify the data of Outbound proxy for secondary proxy:  
Enable/Disable, IP address and Port#.  
Secondary Outbound proxy  
Representative Number  
The representative number is working as a SIP trunk for the  
selected FXS line (for all FXS or FXO/FXS combination  
model) or FXO line (for all FXO model). When an incoming  
call to the representative number, the selected FXS or FXO  
port will be hunted.  
Enable the Line, the default setting is “Enable” and it will  
Enable  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Register or Unregister to SIP Proxy  
Input the SIP Proxy registration account ID.  
Input the phone number.  
Account  
Number  
Input the password of IP Proxy registration account ID.  
Specify the Display name of the phone number  
Specify the Representative forwarding type to be used, only  
choose busy  
Password  
Display name  
Forward  
Specify the number to be forwarded when the specified  
forward condition is met.  
Forward Number  
Ring Type  
Select the Ring Type of representative number. You can  
choose the following:  
z
Serial ring (Follow the ring priority defined  
below)  
z
Simultaneous(ring all)  
Specify the Ring Time for Serial ring  
Ring Time (s) for Serial ring  
Displays the registration status, whether it is registered or not.  
Select the group of representative number, and specify the  
priority.  
Status  
Priority  
Only the checked line will become the member of the  
representative number.  
The default setting L1~L8 is grouped.  
1. Enter the IP address and port number of the SIP proxy into the Primary proxy  
address and Port fields. Press the “Apply” button to save changes.  
2. Press the “Reboot” button to apply the changes.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.Web Administration  
3.1 General configuration  
3.1.1 SIP Advanced Setting  
Specify the local SIP port’s number.  
Local SIP port (1~65535)  
Local RTP port (1~65535)  
Session Expire (Sec)  
Specify the local RTP port’s number.  
Specify the session expire time that will be used to  
negotiate with the remote host or proxy.  
Specify the minimum session expire time that other host  
or proxy will need to follow when calling the MICRONET  
SP5008A/SP5018A/SP5058A.  
Min Session Expire (Sec)  
Session Refresh Request  
Select the session refresh method that will be used on  
the MICRONET SP5008A/SP5018A/SP5058A, you can  
choose among the two methods:  
z
z
UPDATE  
Re-Invite  
Select who will perform the refreshes, you can choose  
among the two methods:  
Session Refresher  
z
z
UAC (Client)  
UAS (Server)  
This will add the parameter refresher=uac or uas in the  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Session Refresh Request message.  
Send SIP unregister signaling message after the  
SP5008A / SP5018A / SP5058A has been restarted  
Use early media treatment SIP protocol, where SIP  
invite messages will not include SDP.  
Unregister All  
Early media Treatment  
Support SIP Ping  
Special feature used with only Nortel’s SIP proxy.  
When this feature is Enabled, all IP outgoing calls’  
Caller ID will not be displayed to the destination.(Please  
make sure your proxy server or soft switch  
supports the feature, if the proxy does not support  
it and you enable this feature, all IP outgoing calls  
will be dropped.)  
IP Anonymous Caller ID  
When Disabled, all IP outgoing calls’ Caller ID will be  
displayed to the destination.  
Support Message Waiting Indication  
(MWI)  
You can Enable or Disable the MWI function.( This  
feature is for FXS only)  
Specify the resend time in seconds for each SIP request  
message that has not received a response.  
Specify the timeout period for SIP Invite messages.  
For example, if the timeout period is 10 seconds, when  
the SP5008A / SP5018A / SP5058A sends an Invite  
message and does not receive a response within 10  
seconds, it will cancel the call.  
SIP Message Resend Timer Base (sec)  
Max. Response Time for Invite  
(1~30sec)  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.2 Payload Type Setting  
Specify the RFC2833 payload type (range is 96~128,  
however 100, 102~105 is reserved by other payload  
types).  
RFC2833 payload type  
Specify the FAX payload type (range is 96~128,  
however 100, 102~105 is reserved by other payload  
types)  
T.38 FAX payload type  
Specify the Redundancy payload type (range is 96~128,  
default value is 104. 100, 102, 103, 105 is reserved by  
other payload types).  
T.38 Redundancy payload type  
T.30 FAX by pass payload type  
Modem by pass payload type  
Modem relay payload type  
Specify the FAX by pass payload type (range is 96~128,  
default value is 102. 100, 103~105 is reserved by  
other payload types).  
Specify the Modem by pass payload type (range is  
96~128, default value is 103. 100, 102, 104, 105 is  
reserved by other payload types).  
Specify the Modem relay payload type (range is  
96~128, default value is 105. 100, 102~104 is  
reserved by other payload types).  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.3 Line Setting  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you enable the No Answer Forward  
function (Representative number or  
L1~L8 number), please specify the  
time of no answer. The default setting  
is 30 sec.  
No Answer Forward Time (FXS only)  
Enable/Disable FAX T.38 function.  
FAX  
Line1~Line8 relevant data  
Displays the port type of that particular line.  
Enable the line or not  
Type  
Enable  
Reg  
Register or Unregister to SIP Proxy  
Displays the line numbers that specified in SIP Setting.  
Account: Input the SIP Proxy registration account ID.  
Number: Input the phone number.  
Number  
Password: Input the password of IP Proxy registration account  
ID.  
Display name: Specify the Display name of the phone  
number.  
The first is the number registers to Primary proxy.  
The default setting is 1000~1007.  
Click the check box to enable hotline feature. If enabled, The  
Enable Hotline  
Hotline Number  
check box will display as  
.
Specify the number to forward the call to when the Hotline  
feature is enabled.  
Specify the time (sec) for wait to hotline, the default value is 0.  
Specify the forwarding type to use, you can choose the  
following:  
Wait to Hotline(sec)  
Forward Type  
z
z
z
z
z
Disable  
Unconditional  
Busy  
No Answer (FXS only)  
Busy and No Answer (FXS only)  
The “Disable” option will allow you to disable this particular  
function.  
Specify the number to forward the call to when the call  
forwarding feature is enabled.  
Forward Number  
Enable/Disable per-line Call Waiting function.  
Enable/Disable per-line DND (Do Not Disturb) function.  
Enable/Disable Greeting for FXO  
Call Waiting (FXS only)  
DND (FXS only)  
Greeting (FXO only)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.4 Qos Setting  
Select Qos Type: DSCP or ToS  
Type  
Differentiated Services Code Point Setting (DSCP)  
Select the DSCP value for RTP (voice packets), the  
DSCP RTP  
value in the drop down list is expressed in binary  
format, you can choose to meet your network  
environment.  
Select the DSCP value for SIP message, the value in  
the drop down list is expressed in binary format, you  
can choose to meet your network environment.  
DSCP Signal  
ToS Setting  
ToS RTP  
Select the ToS value for RTP (voice packets), the  
value in the drop down list is expressed in binary  
format, you can choose to meet your network  
environment.  
Select the ToS value for SIP messages, the value in  
the drop down list is expressed in binary format, you  
can choose to meet your network environment.  
ToS Signal  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.5 Speed Dial Setting  
Speed Dial  
Specify the speed Dial Number/Telephone Number/Name,  
Speed Dial Editor  
then press the Add or Del button to add or delete record  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Peer to Peer call  
You can use speed dial to do the peer to peer call as follows:  
Specify the speed Dial Number/Telephone  
Speed Dial Editor  
Number/Name, then press the Add or Del button  
to add or delete record  
(In P2P application)  
The format of “Telephone Number” is “#@ip  
address: port”, for example  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.6 Caller ID Setting  
Select the (Line 1~Line 8)Caller ID generation  
type to use, you can choose the following:  
Caller ID Setting (Line 1~Line 8)  
z
z
z
z
z
Disable  
DTMF  
FSK(Bellcore)  
ETSI(Before Ring)  
ETSI(Between ring)  
FXO only choose Enable/Disable the caller ID  
detection  
AUTO: You can choose different caller ID type by  
line. If Line1~Line 8 uses the same type, you  
only need to set line 1 and click the “Auto” button,  
then the other lines will set the same type  
automatically.  
The “Disable” option will allow you to disable this  
particular function.  
Specify the DTMF Caller ID Start Symbol  
The default symbol is D.  
DTMF Caller ID Start Symbol  
DTMF Caller ID End Symbol  
Specify the DTMF Caller ID End Symbol  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The default symbol is C.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.7 CDR Setting  
CDR mode  
Select the CDR mode for Enable or Disable. If  
you Enable this feature, please specify the CDR  
Server address and port number at the CDR  
server address and port’s text box, then you can  
get Call Detail Data form CDR Server.  
If you Enable the CDR mode, please specify the  
IP address of CDR Sever for data storage.  
Specify the CDR Server port number,  
CDR Server address  
CDR Server port  
The default port number is 514.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
NOTE: To receive the SYSLOG CDR, you need to have a syslog server to collect  
the CDR from MICRONET SP5008A / SP5018A / SP5058A. The following is a tool  
you can be used for testing purpose which can be downloaded from  
can use it.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.8 Syslog Setting  
This syslog is used to send the debug log from MICRONET SP5008A / SP5018A /  
SP5058A to syslog server.  
Syslog mode  
Select the Syslog mode for Enable or Disable. If  
you Enable this feature, please specify the  
Syslog Server address and port number at the  
Syslog server address and port’s text box, then  
you can get detail system log from Syslog server.  
If you Enable the Syslog mode, please specify  
the IP address of Syslog Sever for data storage.  
Specify the Syslog Server port number,  
Syslog Server address  
Syslog Server port  
The default port number is 514.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
NOTE: To receive the SYSLOG debug information, you need to have a syslogd  
server to collect the debug information from MICRONET SP5008A / SP5018A /  
SP5058A . The following is a tool you can be used for testing purpose which can be  
settings before you can use it.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 Advanced Configuration  
3.2.1 System setting  
PRACK is defined in RFC 3262: Reliability of  
prack  
Provisional Responses in SIP. You can  
accommodate your softswitch (Proxy Server) to  
Enable or Disable this feature.  
Receiver-Off-Hook (ROH) Tone  
ROH (FXS only)  
A ROH tone is sent to the subscriber to inform  
him that his receiver is off-hook.  
You can Enable/Disable this option.  
Polarity Reversal for billing signal, you can  
enable (Reverse)/Disable the feature.  
No attribute (Fax version, BitRate, Buffer,  
Datagram…) indicated in T.38 Re-Invite with  
Session Description Protocol (SDP).  
You can Enable/Disable this option.  
Specify the resend times (0~3)for FAX error  
packet,  
Send billing signal (FXS only)  
T.38 NoAttribute  
FAX redundancy depth  
T.38 FAX Type  
Select the FAX Type to use, you can choose the  
following:  
z
z
T.38  
ByPass  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
Auto  
Select the FAX ByPass Codec to use, you can  
choose the following:  
T.30 FAXByPass Codec  
Flash key function (FXS only)  
Keypad DTMF type  
z
z
z
G.711 a-law  
G.711 u-law  
G.726 32k  
Select the function of Flash key, you can choose  
the following:  
z
z
z
Disable  
Transfer  
SIP Message  
Select the type of Keypad DTMF, you can  
choose the following:  
z
z
z
In-Band  
RFC2833  
SIP Info  
Select the End of dial key, you can choose the  
following:  
End of dial key  
z
z
z
Disable  
*
#
Specify the grade of DTMF Detection Sensitivity,  
the value range is (1~5)  
DTMF Detection Sensitivity  
Dial Wait Timeout (1~60sec)  
Inter Digits Timeout (1~5sec)  
Specify the duration of dial waiting when the  
receiver is off hook. The range is 1~60 sec.  
Specify the interval of input digits, if the interval is  
over the setting, the system will end the dial and  
send out the DTMF. The limitation range is  
1~5sec.  
Some SIP Proxy need specify special keyword  
for FAXByPass function. Input the data as SIP  
Proxy required.  
FAXByPass Keyword  
FAXByPass Keyword  
IP Address announcement  
Some SIP Proxy need specify special keyword  
for FAXByPass function. Input the data as SIP  
Proxy required.  
You can Enable/Disable this function,  
If you select Enable, you can connect T1 port  
with a phone set and press #120#, you will hear  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the announcement of IP address of LAN port, or  
press #126# to get WAN port IP address.  
FXO please following under step:  
1.  
You can get a PSTN line and connect to the  
L1 FXO port.  
2.  
Use another PSTN phone to dial the PSTN  
number (in step 1you connected on  
FXO-08), you will hear a second dial tone  
or greeting (please dial extension number).  
Press #126# on the phone set, and you will  
hear an IVR announcing the current IP  
address of the WAN port.  
3.  
4.  
Press #120# on the phone set, and you will  
hear an IVR announcing the current IP  
address of the LAN port.  
System built-in music of call hold, you can  
Enable/Disable this feature.  
Built-in Call Hold Music  
Specify the DTMF tone duration.  
DTMF Duration  
Specify the interval of DTMF digit  
DTMF Interdigit Time  
Ring Time Limit ( 10~600sec )  
(FXS only)  
Specify the limitation of Ring time for incoming  
call, when the ring is over the limit, system will  
drop the call. The default range is 10~600sec.  
Specify the duration (100~1000ms) of loop  
current drop, 0 for disable. This feature is used  
when the SP5008A (FXS) are connected with  
answering machines. When the remote site  
disconnects, the system will drop FXS port’s  
voltage to 0, and make the answering machines  
disconnect.  
Loop Current Drop Duration (0:disable,  
100~1000ms )  
This option is used when a stand alone relay box  
containing a PSTN and FXS port is connected to  
the SP5008A’s FXS port. In this special  
application, if there is a network or registration  
failure, the system will drop the FXS port’s  
voltage to 0, when the relay box detects the  
status, it will switch the line to PSTN.  
FXS Voltage Drop (FXS only)  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The default setting is “Disable”, if you are not  
using this particular special application  
mentioned above, please do not enable this  
function.  
Specify the IP for pinging to make sure the  
network keeps alive.  
ping ip to keep alive network  
ping timer(sec)  
Specify the interval of ping timer(sec)  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.2 SNTP Setting  
Select the SNTP mode : On or Off  
SNTP mode  
Specify the SNTP server address for time synchronization.  
Select the Time Zone of your location  
SNTP server address  
Time Zone -GMT  
Time setting  
You can specify the time with year/month/date /hour/minute  
/second when you select the SNTP mode with “Off”.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.3 Codec Setting  
You can specify the priority of the codec from First to Fifth (first  
being the highest priority and Fifth being the lowest). You  
can choose the following codec’s:  
Codec Priority  
z
z
z
z
z
G711U  
G711A  
G723  
G729A  
G726  
You can specify the packet size in the drop down list for each  
particular codec, you can choose the following:  
G711U 10,20,30,40,50,60  
Codec Packet Size  
G711A 10,20,30,40,50,60  
G723  
G729A 10,20,30,40,50,60  
G726 10,20,30,40,50,60  
30,60,90  
When you select the codec packet size shown above, system  
will set default requirement of bandwidth.  
Bandwidth Required  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.4 Voice Setting  
Jitter Buffer  
Specify the minimal delay of the jitter buffer. The range is  
0~150 ms and the default setting is 0 ms.  
Minimal Delay  
Specify the maximal delay of the jitter buffer. The range is  
0~200 ms and the default setting is 200 ms.  
Maximal Delay  
OPTFactor  
Specify the dynamic jitter buffer frame error/delay optimization  
factor, the range is 0~13.  
Enable/Disable the VAD (Voice Activity Detection) feature.  
This is supported on all codecs that the FXS-FXO equips.  
Enable/Disable the echo cancellation feature. The default  
setting is “Enable”.  
VAD  
Echo cancellation  
Local voice volume  
Remote receive volume  
DTMF volume  
Specify the volume gain of the voice in the local side (0~63,  
default is 32). You can set this option for each of the 8 lines.  
Specify the volume gain of the voice in the remote side (0~63,  
default is 32). You can set this option for each of the 8 lines.  
Specify the volume gain of the DTMF (0~63, default is 27).  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
You can set this option for each of the 8 lines.  
1. Press the “Apply” button (at the bottom) after you finish to save  
changes.  
2. Press the “Reboot” button to apply the changes.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.5 Tone Setting  
Specify the pattern of the Dial tone, you can adjust the  
high frequency, low frequency, high level, low level, the  
On and Off time for tone 1 and 2.  
Dial tone  
Specify the pattern of the Ringback tone, you can adjust  
the high frequency, low frequency, high level, low level,  
the On and Off time for tone 1 and 2.  
Ringback tone (FXS only)  
Busy tone  
Specify the pattern of the Busy tone, you can adjust the  
high frequency, low frequency, high level, low level, the  
On and Off time for tone 1 and 2.  
Specify the pattern of the call-waiting tone, you can  
adjust the high frequency, low frequency, high level, low  
level, the On and Off time for tone 1 and 2.  
Call-waiting (FXS only)  
Voice-Notify (for FXS+PSTN only)  
ROH Tone (FXS only)  
Specify the pattern of the Voice-Notify, you can adjust  
the high frequency, low frequency, high level, low level,  
the On and Off time for tone 1 and 2.  
Specify the pattern of the ROH Tone, you can adjust the  
high frequency, low frequency, high level, low level, the  
On and Off time for tone 1 and 2. The ROH tone is a  
single high frequency tone used to warn users that their  
phone is not placed on-hook (hang up) correctly.  
Specify the pattern of the disconnect tone for disconnect  
tone 1 (first set), you can adjust the high frequency, low  
frequency, high level, low level, the On and Off time for  
tone 1 and 2.  
Disconnect tone 1  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: If the disconnect tone only has single frequency,  
please set it to low frequency. If the disconnect tone  
only has single cadence, please set it to Tone 1.  
Specify the pattern of the disconnect tone for disconnect  
tone 2 (second set), you can adjust the high frequency,  
low frequency, high level, low level, the On and Off time  
for tone 1 and 2.  
Disconnect tone 2  
NOTE: If the disconnect tone only has single frequency,  
please set it to low frequency. If the disconnect tone  
only has single cadence, please set it to Tone 1.  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.6 Phone Setting  
Primary Ringing  
Specify the Ringing frequency value.  
ringing frequency : 15~100 (Unit : Hz)  
Specify the Ringing ON value.  
Ringing Frequency  
Ringing ON  
Ringing OFF  
Ringing level  
Flash low  
ringing ring ON : 0~8000 (Unit : ms)  
Specify the Ringing OFF value.  
ringing ring OFF : 0~8000 (Unit : ms)  
Specify the ringing level.  
ringing level : 0 ~ 94  
(Unit : V)  
Specify the value of the flash (low).  
: 60~2000 (Unit : ms).  
If the phone-set’s flash time is smaller than the Flash Low  
setting, the flash will be ignored.  
Specify the value of the flash (high).  
: 60~2000 (Unit : ms)  
Flash high  
If the phone-set’s flash time is larger than the Flash high  
setting, the flash will be handled as hang-up.  
Secondary Ringing (FXS only)  
Note: The feature will be enabled automatically when the Min. Digit Count has been enabled and  
specified. It is used to have different ring cadence when the incoming caller number is shorter than  
the setting of “Min. Digit Count”  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specify the Ringing frequency value.  
ringing frequency : 15~100 (Unit : Hz)  
Specify the Ringing ON value.  
Ringing Frequency  
Ringing ON  
ringing ring ON : 0~8000 (Unit : ms)  
Specify the Ringing OFF value.  
ringing ring OFF : 0~8000 (Unit : ms)  
Specify the ringing level.  
Ringing OFF  
Ringing level  
ringing level : 0 ~ 94  
(Unit : V)  
Specify the minimum digit count (1~10, 0: Disable), this  
feature is used to change the ringing frequency by detecting  
the digit length of incoming calls’ number. When the digit  
length of an incoming caller number is greater than the  
specified setting, the system will use primary ringing. If the  
digit is less than the specified setting, the system will use the  
secondary ringing.  
Min. Digit Count  
Specify the ringing standard to use.  
Country  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.7 Digit Manipulation  
This option allows users to test the digit manipulation rule  
you set.  
Digit Manipulation Testing  
Digit Manipulation Editor  
With this option, you can specify whether to add digits to a  
prefix number or drop a prefix number.  
For example, if the user sets:  
First Example  
z
z
z
Prefix: 02 (matched prefix)  
Drop: Enable (drop prefix)  
Insert:  
If the user dials 0282265699, the resulting dial out number  
will be 82265699.  
Second Example  
z
z
z
Prefix: 7  
Drop: Disable  
Insert: 886  
If the user dials 778, the resulting dial out number will be  
886778.  
Third Example (Only applicable for SP5058A FXO)  
z
z
z
Prefix: 8226  
Drop: Disable  
Insert: 02  
If the user dials 82265699, the resulting dial out number  
will be 0282265699.  
You can configure up to 50 entries in the Digit  
Manipulation Editor.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For outgoing call, the default will be made to VOIP.  
However, if you set the FXO prefix here, the call will be  
route to FXO instead of VOIP. It can be applied to FXO  
model only.  
FXO Dial Prefix  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.8 Dial Plan  
Using this feature, users can specify the number that will be  
immediately dialed out without having to press the “#” (at the  
end of the dialed number) on the keypad or until the dial time  
timeout period. The number can be specified depending on  
the length of the dialed number, or the prefix of the dialed  
number.  
Dial Plan Editor  
For example, if the user sets:  
First Example  
z
z
z
Function: Enable  
Leading digit: 02  
Total Digit count: 10  
If the user dials a 10 digit number with a prefix of 02 (e.g.  
0282265699), the MICRONET SP5008A / SP5018A / SP5058A  
will immediately detect it and dial this number straight away.  
Second Example  
z
z
z
Function: Enable  
Leading digit:  
Total digit count: 8  
If the user dials an 8 digit number (e.g. 82265699), the  
MICRONET SP5008A / SP5018A / SP5058A will immediately  
detect it and dial this number straight away.  
Third Example  
z
Function: Disable  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
z
Leading digit: 02  
Total digit count: 10  
If the user set the Function parameter as “Disable”, the call  
number with a length of 10 digits and a prefix of 02 will proceed  
as normal. The user will need to wait until dial timeout period  
for the call to be made, or press the “#” on the keypad at the end  
of the dialing number to make the call.  
You can configure up to 50 entries in the Dial Plan.  
1.Press the “Apply” button (at the bottom) after you finish to save changes.  
2.Press the “Reboot” button to apply the changes.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 Management  
3.3.1 Provision Server  
Note: If you need this requirement, Please contact MICRONET for availabilities.  
Enable/Disable provision function  
Provision server Mode  
Provision server IP address  
Provision server port  
Provision cycle time  
Specify the Provision Server’s IP address.  
Specify the Provision server port  
Specify the cycle time of the provisioning.(unit: sec)  
Specify a scheduled time in a day  
Provision default time  
1. Press the “Apply” button (at the bottom) after you finish to save  
changes.  
2. Press the “Reboot” button to apply the changes.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.2 Save-Reload setting  
Click the “Export” button to export “user.cfg” data  
Specify the file path and file name to Import the configure  
data.  
Export File  
Import File  
Press the “Reboot” button to apply the changes.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.3 Upgrade Firmware  
Select the connection method to update the MICRONET  
SP5008A/SP5018A/SP5058A’s firmware, you can choose  
the following:  
Download mode  
z
z
TFTP  
FTP  
Specify the TFTP/FTP server’s IP address.  
Specify the login username/password for the FTP server.  
Specify the target file name for the firmware.  
Specify the location of the firmware for uploading through  
Http.  
TFTP/FTP server IP address  
FTP login  
Target file name  
Http Upload  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Updating the firmware by FTP  
1. Select FTP mode in the drop down list.  
2. Key in the IP address, login name, password of your FTP server and specify the  
correct filename of the firmware.  
3. Press the Start button (next to the Target file name text box) to execute the  
upgrade process.  
4. Please wait while the device updates itself with the firmware.  
5. After the update process is finish, you will be taken to a web page indicating  
that it was successful (see figure below).  
6. Press the “Reboot” button to apply the changes.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Updating the firmware by TFTP  
1. First, download the TFTP program from our website. Unzip the TFTP to a  
directory that you desire in your hard drive and execute the TFTP program.  
Make sure that the TFTP program points to the directory of where your firmware  
is stored. Now, leave the TFTP program running and switch back to the  
MICRONET SP5008A / SP5018A / SP5058A web configuration interface.  
2. Under Device Management => Software Upgrade select TFTP mode in the  
drop down list.  
3. Key in the IP address of the TFTP server and specify the correct filename of the  
firmware.  
4. Press the Start button (next to the Target file name text box) to execute the  
upgrade process.  
5. Please wait while the device updates itself with the firmware.  
6. After the update process is finish, you will be taken to a web page indicating  
that it was successful (see figure below).  
7. Press the “Reboot” button to apply the changes.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Updating the firmware by HTTP  
1. Under Device Management => Software Upgrade web menu, specify the  
location of the firmware by clicking the Browse button next to the Http Upload  
text box.  
2. You will be prompted with a window requesting the location of the firmware.  
3. Locate the firmware that is stored in your hard drive.  
4. Once located, click the Open button.  
5. Back in the web configuration menu, press the Start button (next to the Http  
Upload’s browse button) to execute the upgrade process.  
6. Please wait while the device updates itself with the firmware.  
7. After the update process is finish, you will be taken to a web page indicating  
that it was successful (see figure below).  
Note: For consistency, it is recommended to reload default setting every time you  
update the firmware on the MICRONET SP5008A /SP5018A / SP5058A. However,  
you will lose all the settings configured on the MICRONET SP5008A / SP5018A /  
SP5058A except Network configuration. For more details on reload default setting,  
please refer to the next page below.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.4 Reset to Default  
Users can restore back to factory default settings using this feature. The password  
of the account and the network configurations are the things that will not be  
changed when this feature is executed.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.5 Network Status  
Displays the current connection mode.  
Connection mode  
Current IP address  
Subnet mask  
Displays the current IP address of the WAN port.  
Displays the current subnet mask’s IP.  
Displays the current default gateway’s IP.  
Displays the current primary DNS address.  
Displays the current secondary DNS address.  
Displays the MAC address of the WAN port.  
Default gateway  
Primary DNS address  
Second DNS address  
WAN MAC  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.6 Version Info.  
Displays the current boot version loaded on the MICRONET  
SP5008A / SP5018A / SP5058A.  
Boot version  
Displays the current post version loaded on the MICRONET  
SP5008A / SP5018A / SP5058A.  
Post version  
Displays the current application version loaded on the  
MICRONET SP5008A / SP5018A / SP5058A.  
Application version  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.7 Port Status  
Displays the corresponding port number.  
Displays the status of the port.  
Item  
Status  
Port Type  
Displays the port type (FXS,FXO)of the corresponding port  
number.  
Displays the registration status of the corresponding port  
number. if the port  
Register Proxy  
Register success it will display “Yes” .  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3.8 Password  
Select the type of user name that you would like to configure  
the password for, you can choose the following:  
Username  
z
z
root  
user  
Specify the current password for the user selected in the drop  
down list above.  
Current password  
New password  
Specify the new password for the user selected in the drop  
down list above.  
Repeat the new password again for confirmation.  
Confirm new password  
1.  
2.  
Press the “Apply” button (at the bottom) after you finish to save changes.  
Press the “Reboot” button to apply the changes.  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 Rebooting the system  
Executing this function will reboot the whole system, when configuration changes  
are made to the device, it needs to be rebooted for the changes to take effect (see  
figure below).  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.Operation  
4.1 Peer to Peer mode (FXO to FXS)  
In this application, the distance of PABX extension is not limited. You can use the  
same PABX in two or more branches.  
Configuration:  
1. Side A (FXO): IP address: 10.1.1.2, number is 2000 to 2008  
2. Side B (FXS): IP address: 10.1.1.3, number is 1000 to 1008  
Side A : (SP5058A: IP address 10.1.1.2)  
General Configuration / SIP Setting  
Specify the destination (Side B) IP Address of  
Peer to Peer mode, and specify the port# with  
5076.  
Primary proxy/P2P IP  
(Side A--FXO)  
Call number configuration  
Representative number  
(Side A -- FXO)  
Enable the representative line  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Side A : (SP5058A : IP address 10.1.1.2)  
General Configuration / Line Setting  
Line 1~Line 8  
Please refer to the figure shown above, Enable  
all the line and Disable all the register.  
Specify the relevant data: Account, number,  
password and display name.  
(Side A -- FXO)  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Side B: (MICRONET SP5008A : IP address 10.1.1.3)  
General Configuration—SIP Setting  
Specify the destination (Side A) IP Address of  
Primary proxy/P2P IP  
(Side B)  
Peer to Peer mode, and specify the port# with  
5076  
Call number configuration  
Representative number  
(Side B)  
Enable the representative line  
Line 1~Line 8  
Please refer to the figure shown above, Enable  
all the line and Disable all the register.  
Specify the relevant data: Account, number,  
password and display name.  
(Side B)  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Side B: (MICRONET SP5008A: IP address 10.1.1.3)  
General Configuration / Line Setting  
Line 1~Line 8  
(Side B)  
Please refer to the figure shown above, Enable  
all the line and Disable all the register and call  
waiting.  
Specify the relevant data: Account, number,  
password and display name  
1. Press the “Apply” button (at the bottom) after you finish to save changes.  
2. Press the “Reboot” button to apply the changes.  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2 Peer to Peer mode (FXS to FXS)  
Peer A—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address  
is: 192.168.23.14)  
Peer B—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address  
is: 192.168.23.58)  
Peer A—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address  
is: 192.168.23.14)  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Peer B—MICRONET SP5008A / SP5018A / SP5058A (for example the IP  
address is: 192.168.23.58)  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specify the destination IP Address of Peer to  
Peer mode, and specify the port# with 5076.  
In this application, we define the Peer to Peer  
mode in 2 groups. If you want to make call  
to others IP addresses, please refer to the  
paragraph 3.3.7 Speed dial setting.  
Primary proxy/P2P IP  
(Peer A / Peer B)  
Call number configuration  
Representative number  
(Peer A / Peer B)  
Enable the representative line  
Line 1~Line 8  
Please refer to the figure shown above, Enable  
all the line and Disable all the register of two  
sides.  
(Peer A / Peer B)  
Specify the relevant data: Account, number,  
password and display name.  
3. Press the “Apply” button (at the bottom) after you finish to save changes.  
4. Press the “Reboot” button to apply the changes.  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specification  
Model  
SP5008A  
Standard  
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and Secondary  
Outbound Proxy  
8 FXS  
POTS Interface  
Ethernet Port  
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M  
4 x RJ-45 LAN ports of 10/100M  
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A  
VAD, CNG, and Silence Suppression  
Echo Cancellation (G.165 / G.168)  
Adaptive Jitter Buffer  
Voice  
Packet Loss Compensation  
Adjustable volume level  
DTMF  
In-band, SIP Info, RFC2833  
Telephony  
z
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)  
Call hold, Call transfer, Call waiting, Call forward (Unconditional, No  
answer, Busy, No Answer+Busy)  
z
z
z
z
z
z
z
z
Music on Hold  
Hotline and Waiting Time to Hotline  
Speed Dial and Peer-to-Peer Call  
Anonymous Call  
DND (Do Not Disturb)  
Dial Plan and Digit Manipulation  
Tone Generation/Detection: Ringing Tone, Ring Back Tone, Dial Tone,  
Programmable Tone  
z
z
z
z
z
z
z
z
z
z
z
CDR (Call Detail Record)  
MWI (Message Waiting Indication)  
FAX over IP: G.711 pass-through, T.38 Fax relay  
Representative number setting  
PBX Features  
Support SIP Trunk  
Extension calling among FXS ports  
Direct line (DID) to extension  
Max. 9 registrars (SIP trunk and 8 direct lines)  
Operator (Serial ring on extension) for attendant  
HTTP 1.1 basic/digest authentication for WEB access  
MD5 for SIP authentication (RFC 2069/2617)  
Security  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
z
z
z
z
z
Password protected for Admin access authority  
PPPoE Client, DHCP Client / Server, NAT, SNTP  
QoS: DiffServ / ToS  
Networking  
Management  
User interface: HTTP and Telnet  
Firmware upgrade via FTP/TFTP/HTTP/Telnet  
Auto Provisioning  
Environment  
z
z
z
z
Operating Temperature: 0 – 45 degree C  
Storage Temperature: 0 – 55 degree C  
Operating Humidity: 10 to 85% (non-condensing)  
Storage Humidity: 10 to 95% (non-condensing)  
Power Supply  
Emission  
DC 12V, 3A  
CE  
FCC Part 15, Class B  
Model  
SP5018A  
Standards  
z
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and  
Secondary Outbound Proxy  
Interface  
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M  
4 x RJ-45 LAN ports of 10/100M  
4 x RJ-11 FXS ports for connecting with phone set and fax machine  
4 x RJ-11 FXO ports for connecting with PSTN line or PABX’s extension  
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A  
VAD, CNG, and Silence Suppression  
Voice Processing  
Echo Cancellation (G.165 / G.168)  
Adaptive Jitter Buffer  
Packet Loss Compensation  
Adjustable volume level  
DTMF relay: In-band, RFC 2833, SIP Info  
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)  
Call hold  
Call Features  
Call transfer (blind & consultant)  
Call forward (Unconditional, No answer, Busy)  
MWI (Message Waiting Indication)  
FAX over IP: G.711 pass-through, T.38 Fax relay  
PSTN Lifeline: PSTN bypass if network or system fails  
Detection of disconnect tone, polarity reversal, and loop current drop (zero  
voltage) on FXO ports  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
z
z
z
z
z
z
z
z
z
z
z
z
z
HTTP 1.1 basic/digest authentication for WEB access  
MD5 for SIP authentication (RFC 2069/2617)  
Password protected for Admin access authority  
PPPoE Client, DHCP Client / Server, NAT, SNTP  
QoS: DiffServ / ToS  
Networking  
Management  
User interface: HTTP and Telnet  
Firmware upgrade via FTP/TFTP/HTTP/Telnet  
Auto Provisioning  
Power Supply  
Environment  
DC 12V, 3A  
Operating Temperature: 0 – 45 degree C  
Storage Temperature: 0 – 55 degree C  
Operating Humidity: 10 to 85% (non-condensing)  
Storage Humidity: 10 to 95% (non-condensing)  
35 × 242 × 160 (mm)  
Dimension  
Emission  
z
z
CE  
FCC Part 15, Class B  
Model  
SP5058A  
Standards  
z
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and Secondary  
Outbound Proxy  
Interface  
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M  
4 x RJ-45 LAN ports of 10/100M  
8 x RJ-11 FXO ports for connecting with PSTN line or PABX’s extension  
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A  
VAD, CNG, and Silence Suppression  
Voice Processing  
Echo Cancellation (G.165 / G.168)  
Adaptive Jitter Buffer  
Packet Loss Compensation  
DTMF relay: In-band, RFC 2833, SIP Info  
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)  
Call hold  
Call Features  
Call transfer (blind & consultant)  
Call forward (Unconditional, No answer, Busy)  
FAX over IP: G.711 pass-through, T.38 Fax relay  
Detection of disconnect tone, polarity reversal, and loop current drop (zero  
voltage) on FXO ports  
Security  
z
HTTP 1.1 basic/digest authentication for WEB access  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
z
z
z
z
z
z
z
z
z
z
z
MD5 for SIP authentication (RFC 2069/2617)  
Password protected for Admin access authority  
PPPoE Client, DHCP Client / Server, NAT, SNTP  
QoS: DiffServ / ToS  
Networking  
Management  
User interface: HTTP and Telnet  
Firmware upgrade via FTP/TFTP/HTTP/Telnet  
Auto Provisioning  
Power Supply  
Environment  
DC 12V, 3A  
Operating Temperature: 0 – 45 degree C  
Storage Temperature: 0 – 55 degree C  
Operating Humidity: 10 to 85% (non-condensing)  
Storage Humidity: 10 to 95% (non-condensing)  
35 × 242 × 160 (mm)  
Dimension  
Emission  
z
z
CE  
FCC Part 15, Class B  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Oven M Nr 09 786 840 User Manual
Miller Electric Welder H 10 User Manual
Multiquip Trash Compactor MVC 82VH User Manual
Murphy Switch L1100 User Manual
NordicTrack Treadmill NTTL25510 User Manual
Numark Industries DJ Equipment TT1625 User Manual
NuTone Universal Remote ICA 441WHW User Manual
Oster Waffle Iron 3862 User Manual
Panasonic Air Conditioner CW XC120AU User Manual
Paradyne Network Card 8610 User Manual