User’s Manual
IP Telephony Gateway
Model No.: SP5008A, SP5018A, SP5058A
Website: http://www.micronet.info
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Content
1. ..Introduction.............................................................................................. 4
1.1 Key Features................................................................................................ 4
1.2 Physical Description..................................................................................... 5
2. ..Startup ...................................................................................................... 7
2.1 Login into the System................................................................................... 7
2.2 Network Configuration.................................................................................. 9
2.2.1 Static IP ..........................................................................................................11
2.2.2 DHCP ............................................................................................................ 12
2.2.3 PPPoE........................................................................................................... 13
2.2.4 LAN Setting ................................................................................................... 14
2.3 General configuration................................................................................. 16
2.3.1 PABX Mode (SP5018A only)......................................................................... 16
2.3.2 SIP Setting .................................................................................................... 18
3. ..Web Administration ............................................................................... 20
3.1 General configuration................................................................................. 20
3.1.1 SIP Advanced Setting.................................................................................... 20
3.1.2 Payload Type Setting .................................................................................... 22
3.1.3 Line Setting ................................................................................................... 24
3.1.4 Qos Setting.................................................................................................... 27
3.1.5 Speed Dial Setting......................................................................................... 28
3.1.6 Caller ID Setting ............................................................................................ 30
3.1.7 CDR Setting .................................................................................................. 32
3.1.8 Syslog Setting ............................................................................................... 34
3.2 Advanced Configuration............................................................................. 36
3.2.1 System setting............................................................................................... 36
3.2.2 SNTP Setting................................................................................................. 40
3.2.3 Codec Setting................................................................................................ 41
3.2.4 Voice Setting ................................................................................................. 42
3.2.5 Tone Setting .................................................................................................. 44
3.2.6 Phone Setting................................................................................................ 46
3.2.7 Digit Manipulation.......................................................................................... 48
3.2.8 Dial Plan........................................................................................................ 50
3.3 Management .............................................................................................. 52
3.3.1 Provision Server............................................................................................ 52
3.3.2 Save-Reload setting...................................................................................... 53
3.3.3 Upgrade Firmware......................................................................................... 54
2
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.4 Reset to Default............................................................................................. 58
3.3.5 Network Status .............................................................................................. 59
3.3.6 Version Info. .................................................................................................. 60
3.3.7 Port Status..................................................................................................... 61
3.3.8 Password....................................................................................................... 62
3.4 Rebooting the system................................................................................. 63
4. ..Operation................................................................................................ 64
4.1 Peer to Peer mode (FXO to FXS)............................................................... 64
4.2 Peer to Peer mode (FXS to FXS)............................................................... 68
5. ..Specification........................................................................................... 72
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
Micronet SP5008A / SP5018A / SP5058A are high-capacity SIP Gateway
Series that provides 8 FXS / 4 FXS + 4 FXO / 8 FXO ports, and suit to build an
IP-based communication platform with other VoIP devices. They meet enterprise’s
requirement for functionality (VoIP) upgrade and larger scale implementation by
interoperating with legacy PABX and IP PBX/Soft-switch.
To connect with legacy PABX, SP5018A supports PABX Mode for PSTN
backup. When network or power fails, PSTN lines (FXO) bypass to FXS ports and
users still can make/receive calls via PSTN lines.
In addition, SP5008A includes some wonderful PABX features for small
business. They help operate users on various VoIP applications, such as extension
calling among 8 FXS ports, inbound/outbound calls via SIP trunk, DID (direct line),
DOD, prefix routing, operator attendant, etc. Users can easily benefit from the
ease-to-use device.
1.1 Key Features
z
z
z
z
z
z
IETF SIP standards compliant
Support 1 RJ-45 WAN port and 4 RJ-45 LAN ports
Support POTS interfaces: 8 FXS / 4 FXS + 4 FXO / 8 FXO ports
Support single-account registration on FXS ports for representative number
Support extension calling among FXS ports
Support rich call features: call hold, call transfer, call forward, hotline, warm line,
speed dial, anonymous call, P2P call, etc
z
z
z
Support PSTN prefix routing (SP5018A only)
Support PABX mode for legacy PABX function upgrade (SP5018A only)
Support PSTN lifeline – PSTN bypass in case of power or registration failure
(SP5018A only)
z
z
Support detection of disconnect tone, polarity reversal, and loop current drop
(zero voltage) on FXO ports
Well interoperability with industry-leading IP-PBX/Soft-Switch, such as Alcatel,
Lucent, Siemens, etc.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 Physical Description
SP5008A:
SP5008A Front Panel
SP5058A
SP5018A
SP5058A Front Panel
SP5018A Front Panel
LED Indicators
LED
Status
Description
POWER
READY
PROXY
On / Green
The Power is on
Blink / Green
Blink / Green
Constant / Green
Blink / Green
Booting up for self test
Gateway reg. fails
Gateway reg. successes
WAN
Transmitting or receiving data /Network
connection established
LAN(1-4)
T(1*)
Blink / Green
Transmitting or receiving data /Network
connection established
On / Orange
Off
Busy / Off-hook
Available / On-hook
Busy
L(1*)
On / Orange
Off
Available
5
Download from Www.Somanuals.com. All Manuals Search And Download.
1*. SP5008A: FXS = T1 - T8
SP5018A: FXS = T1 - T4, FXO = L1 - L4
SP5058A: FXO = L1 - L8
SP5008A
SP5008A Rear Panel
SP5058A
SP5018A
SP5058A Rear Panel
SP5018A Rear Panel
---------------------------------------------------------------------------------------------------
RESET
T1-T8
Factory default button. Press and hold for 5 seconds to reset
The RJ-11 FXS port 1-8, connects analog phone sets, trunk line in PABX.
The RJ-11 FXO port 1-8, connect to PSTN
L1-L8
T1/P1-T4/P4
It is a pair of FXO and FXS connector. The different is that the when power off
or application is crashed, the FXO and FXS will be connected together
automatically for local surviving.
WAN
RJ-45 port of 10/100M for connecting to modem
LAN(1-4)
DC 12V
RJ-45 port of 10/100M for connecting to PC or hub/switch that connects PCs
The power socket, input AC 100V~120V; output DC12V.3A
---------------------------------------------------------------------------------------------------
6
Download from Www.Somanuals.com. All Manuals Search And Download.
2.Startup
2.1 Login into the System
First of all, connect your computer to MICRONET SP5008A / SP5018A / SP5058A’s
LAN port by using DHCP. The IP address assign to your computer should be
192.168.123.x by default. Once you can get the IP address from MICRONET
SP5008A / SP5018A / SP5058A, you can start the configuration as below.
Step 1. Connect LAN port to your managing PC. Or, connect the gateway with PC
by hub/switch.
IP address of PC with 192.168.123.x. Or set up your PC in DHCP mode to
get IP address automatically.
Step 3. The Password screen now appears. Type “root” in the user name field,
and your password (none by default) in the password field.
Step 4. You will enter the main page of the web configuration interface after you
keyed in the username and password correctly (see figure below).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Network Configuration
By default, the gateway is in NAT mode (router mode) and can share Internet
access with PCs. Go to [ Network Configuration / WAN Setting ], and configure
WAN setting according to actual condition. In default IP type of DHCP client, it
requests necessary IP information from your ISP automatically.
-----------------------------------------------------------------------------------------------------
Note:
1. Different ISPs require different methods of connecting to the Internet. Please consult your
ISP to select right IP type (Fixed IP, PPPoE) of WAN.
2. You can retrieve the IP address of the WAN port by keying #126# on the phone set that is
connected to the FXS port of the gateway. You will hear an IVR announcing the current IP
address of the WAN port.
-----------------------------------------------------------------------------------------------------
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WAN Setting
Item
Description
Static IP
DHCP
PPPoE
Connected mode
Select the connection method for
the WAN port of the
SP5008A/SP5018A/SP5058A, you
can choose the following:
V
V
V
V
V
V
z
z
z
Static IP
DHCP
PPPoE
Current IP Address
DNS server mode
Show current IP address
Select the DNS behavior, you can
choose the following:
z
z
Auto
Manual
“DNS auto” will retrieve the DNS
information sent from the DHCP
server.
V
V
V
“Manual” will look at the specified
Primary and Secondary DNS
address.
Primary DNS
address
Specify the address of the Primary
DNS.
V
V
V
V
V
V
Secondary DNS
address
Specify the address of the
Secondary DNS.
WAN Link Speed
Select the connection speed for the
WAN port of the
SP5008A/SP5018A/SP5058A, you
can choose the following:
V
V
V
V
V
z
z
z
Auto
100M
10M
HTTP port for WEB
management
Specify the port number for WEB
management, the allowable range is
80,1024~65535.
V
IP address
Specify the IP address.
V
V
Subnet mask
Specify the subnet mask.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Static IP
V
DHCP
PPPoE
Default gateway
Specify the IP address of the default
gateway.
Remote access
restriction
Restricts/Blocks users connecting to
the WAN port’s IP remotely, you can
Enable/Disable this option.
Specify the username of the PPPoE
account
V
V
V
PPPoE userID
V
V
PPPoE password
Specify the password associated to
the PPPoE account above.
When the remote host (PPPoE)
fails, the gateway will retry 3 times
to reconnect, if there is no reply
from the remote host within 3 tries,
then the gateway will reboot. You
can Enable/Disable this option.
Reboot after remote
host disconnection
V
2.2.1 Static IP
1. Press the “Apply” button (at the bottom) after you finish to save changes.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Press the “Reboot” button to apply the changes.
2.2.2 DHCP
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
-----------------------------------------------------------------------------------------------------
Note:
When you are using DHCP in WAN and not connected, please make sure you connect Ethernet
before use PC to connect to LAN port.
-----------------------------------------------------------------------------------------------------
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.3 PPPoE
1. Input PPPoE user ID and password
2. Press the “Apply” button (at the bottom) after you finish to save changes.
3. Press the “CANCEL” button (next to the Apply button) to clear the values in
the page.
4. Press the “Reboot” button to apply the changes.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.4 LAN Setting
ITEM
Description
LAN IP address
Specify the IP address of the SP5008A /
SP5018A / SP5058A LAN port.
LAN mask address
DHCP server
Specify the mask address for SP5008A /
SP5018A / SP5058A LAN port.
Enable/Disable DHCP function on the LAN port.
Once enabled, the LAN ports will function as a
DHCP server, network devices connected to
them will be issued with IP addresses.
When DHCP is enabled, you can specify the IP
address to start from when assigning to attach
network devices.
IP address from
IP address to
When DHCP is enabled, you can specify the
ending IP address assigned to the attached
network devices.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ITEM
Description
Domain Name
You can specify the domain name that will be
assigned by the DHCP server to the attached
network devices. The DHCP server will send
information on the “server host name” to the
DHCP client.
Lease time(sec)
You can specify the maximum lease time of the
IP address allocated to the DHCP client.
Select the DNS behavior, you can choose the
following:
DNS server mode
z
z
Auto
Manual
“DNS auto” will retrieve the DNS information sent
from the DHCP server.
“Manual” will look at the specified Primary and
Secondary DNS address.
Primary DNS address
Specify the address of the Primary DNS.
Specify the address of the Secondary DNS.
Secondary DNS address
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3 General configuration
To make VoIP calls, you will need a SIP account provided by the SIP Proxy you are
registered with. To configure the relevant SIP settings, please refer to the
instructions explained below.
2.3.1 PABX Mode (SP5018A only)
This quick setting is used for MICRONET SP5018A to operate in PABX connection
mode between PSTN and traditional PABX. Enable PABX mode for ISP/ITSP
scenario that forbids SIP call to/from PSTN via the gateway (SP5018A). The call
scenario will be working as below:
1. For FXO incoming call, it will route to corresponding FXS directly (1 by 1)
2. For FXS outgoing call, it will route to VOIP except those prefix set in FXO
dialing Prefix.
3. For VOIP incoming call, it will route to FXS based on the called number
4. When VOIP call is failed to be called out such as register fail or network
issue, the call will be route to FXO as backup.
5. When MICRONET SP5008A / SP5018A / SP5058A is malfunction or
power failure, the all call will be directly bypassed to FXO.
To enable PABX behavior or not.
PABX Connection
SIP Setting
Please refer to 3.3.2.1
It is used (Yes) when you only have 1 SIP account and
would like to be shared for all FXS lines. Please refer to
Representative Number Only
16
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.2.1
When you have multiple SIP accounts for each FXS line,
please set Representative Number Only to No. Then refer
to 3.3.2.1 for the detail
Primary FXS SIP settings
FXO Dialing Prefix
When the prefix is set here, the call will be route to FXO
instead of VOIP.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.2 SIP Setting
Specify the data of primary proxy : Enable/Disable, IP
address, Port#, Domain Name, Expire time and MWI TTL.
The P2P mode will be explained in paragraph Appendix A
Specify the data of secondary proxy: Enable/Disable, IP
address, Port#, Domain Name, Expire time and MWI TTL.
When you enable secondary proxy, it will start to register no
matter whether primary proxy is registered or not. However, it
will be used only when primary proxy is not registered or the
incoming call is coming from it.
Primary proxy/P2P IP
Secondary proxy
Specify the data of Outbound proxy: Enable/Disable, IP
address and Port#.
Outbound proxy
Specify the data of Outbound proxy for secondary proxy:
Enable/Disable, IP address and Port#.
Secondary Outbound proxy
Representative Number
The representative number is working as a SIP trunk for the
selected FXS line (for all FXS or FXO/FXS combination
model) or FXO line (for all FXO model). When an incoming
call to the representative number, the selected FXS or FXO
port will be hunted.
Enable the Line, the default setting is “Enable” and it will
Enable
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Register or Unregister to SIP Proxy
Input the SIP Proxy registration account ID.
Input the phone number.
Account
Number
Input the password of IP Proxy registration account ID.
Specify the Display name of the phone number
Specify the Representative forwarding type to be used, only
choose busy
Password
Display name
Forward
Specify the number to be forwarded when the specified
forward condition is met.
Forward Number
Ring Type
Select the Ring Type of representative number. You can
choose the following:
z
Serial ring (Follow the ring priority defined
below)
z
Simultaneous(ring all)
Specify the Ring Time for Serial ring
Ring Time (s) for Serial ring
Displays the registration status, whether it is registered or not.
Select the group of representative number, and specify the
priority.
Status
Priority
Only the checked line will become the member of the
representative number.
The default setting L1~L8 is grouped.
1. Enter the IP address and port number of the SIP proxy into the Primary proxy
address and Port fields. Press the “Apply” button to save changes.
2. Press the “Reboot” button to apply the changes.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
3.Web Administration
3.1 General configuration
3.1.1 SIP Advanced Setting
Specify the local SIP port’s number.
Local SIP port (1~65535)
Local RTP port (1~65535)
Session Expire (Sec)
Specify the local RTP port’s number.
Specify the session expire time that will be used to
negotiate with the remote host or proxy.
Specify the minimum session expire time that other host
or proxy will need to follow when calling the MICRONET
SP5008A/SP5018A/SP5058A.
Min Session Expire (Sec)
Session Refresh Request
Select the session refresh method that will be used on
the MICRONET SP5008A/SP5018A/SP5058A, you can
choose among the two methods:
z
z
UPDATE
Re-Invite
Select who will perform the refreshes, you can choose
among the two methods:
Session Refresher
z
z
UAC (Client)
UAS (Server)
This will add the parameter refresher=uac or uas in the
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Session Refresh Request message.
Send SIP unregister signaling message after the
SP5008A / SP5018A / SP5058A has been restarted
Use early media treatment SIP protocol, where SIP
invite messages will not include SDP.
Unregister All
Early media Treatment
Support SIP Ping
Special feature used with only Nortel’s SIP proxy.
When this feature is Enabled, all IP outgoing calls’
Caller ID will not be displayed to the destination.(Please
make sure your proxy server or soft switch
supports the feature, if the proxy does not support
it and you enable this feature, all IP outgoing calls
will be dropped.)
IP Anonymous Caller ID
When Disabled, all IP outgoing calls’ Caller ID will be
displayed to the destination.
Support Message Waiting Indication
(MWI)
You can Enable or Disable the MWI function.( This
feature is for FXS only)
Specify the resend time in seconds for each SIP request
message that has not received a response.
Specify the timeout period for SIP Invite messages.
For example, if the timeout period is 10 seconds, when
the SP5008A / SP5018A / SP5058A sends an Invite
message and does not receive a response within 10
seconds, it will cancel the call.
SIP Message Resend Timer Base (sec)
Max. Response Time for Invite
(1~30sec)
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.2 Payload Type Setting
Specify the RFC2833 payload type (range is 96~128,
however 100, 102~105 is reserved by other payload
types).
RFC2833 payload type
Specify the FAX payload type (range is 96~128,
however 100, 102~105 is reserved by other payload
types)
T.38 FAX payload type
Specify the Redundancy payload type (range is 96~128,
default value is 104. 100, 102, 103, 105 is reserved by
other payload types).
T.38 Redundancy payload type
T.30 FAX by pass payload type
Modem by pass payload type
Modem relay payload type
Specify the FAX by pass payload type (range is 96~128,
default value is 102. 100, 103~105 is reserved by
other payload types).
Specify the Modem by pass payload type (range is
96~128, default value is 103. 100, 102, 104, 105 is
reserved by other payload types).
Specify the Modem relay payload type (range is
96~128, default value is 105. 100, 102~104 is
reserved by other payload types).
22
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.3 Line Setting
24
Download from Www.Somanuals.com. All Manuals Search And Download.
If you enable the No Answer Forward
function (Representative number or
L1~L8 number), please specify the
time of no answer. The default setting
is 30 sec.
No Answer Forward Time (FXS only)
Enable/Disable FAX T.38 function.
FAX
Line1~Line8 relevant data
Displays the port type of that particular line.
Enable the line or not
Type
Enable
Reg
Register or Unregister to SIP Proxy
Displays the line numbers that specified in SIP Setting.
Account: Input the SIP Proxy registration account ID.
Number: Input the phone number.
Number
Password: Input the password of IP Proxy registration account
ID.
Display name: Specify the Display name of the phone
number.
The first is the number registers to Primary proxy.
The default setting is 1000~1007.
Click the check box to enable hotline feature. If enabled, The
Enable Hotline
Hotline Number
check box will display as
.
Specify the number to forward the call to when the Hotline
feature is enabled.
Specify the time (sec) for wait to hotline, the default value is 0.
Specify the forwarding type to use, you can choose the
following:
Wait to Hotline(sec)
Forward Type
z
z
z
z
z
Disable
Unconditional
Busy
No Answer (FXS only)
Busy and No Answer (FXS only)
The “Disable” option will allow you to disable this particular
function.
Specify the number to forward the call to when the call
forwarding feature is enabled.
Forward Number
Enable/Disable per-line Call Waiting function.
Enable/Disable per-line DND (Do Not Disturb) function.
Enable/Disable Greeting for FXO
Call Waiting (FXS only)
DND (FXS only)
Greeting (FXO only)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.4 Qos Setting
Select Qos Type: DSCP or ToS
Type
Differentiated Services Code Point Setting (DSCP)
Select the DSCP value for RTP (voice packets), the
DSCP RTP
value in the drop down list is expressed in binary
format, you can choose to meet your network
environment.
Select the DSCP value for SIP message, the value in
the drop down list is expressed in binary format, you
can choose to meet your network environment.
DSCP Signal
ToS Setting
ToS RTP
Select the ToS value for RTP (voice packets), the
value in the drop down list is expressed in binary
format, you can choose to meet your network
environment.
Select the ToS value for SIP messages, the value in
the drop down list is expressed in binary format, you
can choose to meet your network environment.
ToS Signal
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.5 Speed Dial Setting
Speed Dial
Specify the speed Dial Number/Telephone Number/Name,
Speed Dial Editor
then press the Add or Del button to add or delete record
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Peer to Peer call
You can use speed dial to do the peer to peer call as follows:
Specify the speed Dial Number/Telephone
Speed Dial Editor
Number/Name, then press the Add or Del button
to add or delete record
(In P2P application)
The format of “Telephone Number” is “#@ip
address: port”, for example
[email protected]:5060
29
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.6 Caller ID Setting
Select the (Line 1~Line 8)Caller ID generation
type to use, you can choose the following:
Caller ID Setting (Line 1~Line 8)
z
z
z
z
z
Disable
DTMF
FSK(Bellcore)
ETSI(Before Ring)
ETSI(Between ring)
FXO only choose Enable/Disable the caller ID
detection
AUTO: You can choose different caller ID type by
line. If Line1~Line 8 uses the same type, you
only need to set line 1 and click the “Auto” button,
then the other lines will set the same type
automatically.
The “Disable” option will allow you to disable this
particular function.
Specify the DTMF Caller ID Start Symbol
The default symbol is D.
DTMF Caller ID Start Symbol
DTMF Caller ID End Symbol
Specify the DTMF Caller ID End Symbol
30
Download from Www.Somanuals.com. All Manuals Search And Download.
The default symbol is C.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.7 CDR Setting
CDR mode
Select the CDR mode for Enable or Disable. If
you Enable this feature, please specify the CDR
Server address and port number at the CDR
server address and port’s text box, then you can
get Call Detail Data form CDR Server.
If you Enable the CDR mode, please specify the
IP address of CDR Sever for data storage.
Specify the CDR Server port number,
CDR Server address
CDR Server port
The default port number is 514.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
NOTE: To receive the SYSLOG CDR, you need to have a syslog server to collect
the CDR from MICRONET SP5008A / SP5018A / SP5058A. The following is a tool
you can be used for testing purpose which can be downloaded from
can use it.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.8 Syslog Setting
This syslog is used to send the debug log from MICRONET SP5008A / SP5018A /
SP5058A to syslog server.
Syslog mode
Select the Syslog mode for Enable or Disable. If
you Enable this feature, please specify the
Syslog Server address and port number at the
Syslog server address and port’s text box, then
you can get detail system log from Syslog server.
If you Enable the Syslog mode, please specify
the IP address of Syslog Sever for data storage.
Specify the Syslog Server port number,
Syslog Server address
Syslog Server port
The default port number is 514.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
NOTE: To receive the SYSLOG debug information, you need to have a syslogd
server to collect the debug information from MICRONET SP5008A / SP5018A /
SP5058A . The following is a tool you can be used for testing purpose which can be
settings before you can use it.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 Advanced Configuration
3.2.1 System setting
PRACK is defined in RFC 3262: Reliability of
prack
Provisional Responses in SIP. You can
accommodate your softswitch (Proxy Server) to
Enable or Disable this feature.
Receiver-Off-Hook (ROH) Tone
ROH (FXS only)
A ROH tone is sent to the subscriber to inform
him that his receiver is off-hook.
You can Enable/Disable this option.
Polarity Reversal for billing signal, you can
enable (Reverse)/Disable the feature.
No attribute (Fax version, BitRate, Buffer,
Datagram…) indicated in T.38 Re-Invite with
Session Description Protocol (SDP).
You can Enable/Disable this option.
Specify the resend times (0~3)for FAX error
packet,
Send billing signal (FXS only)
T.38 NoAttribute
FAX redundancy depth
T.38 FAX Type
Select the FAX Type to use, you can choose the
following:
z
z
T.38
ByPass
36
Download from Www.Somanuals.com. All Manuals Search And Download.
z
Auto
Select the FAX ByPass Codec to use, you can
choose the following:
T.30 FAXByPass Codec
Flash key function (FXS only)
Keypad DTMF type
z
z
z
G.711 a-law
G.711 u-law
G.726 32k
Select the function of Flash key, you can choose
the following:
z
z
z
Disable
Transfer
SIP Message
Select the type of Keypad DTMF, you can
choose the following:
z
z
z
In-Band
RFC2833
SIP Info
Select the End of dial key, you can choose the
following:
End of dial key
z
z
z
Disable
*
#
Specify the grade of DTMF Detection Sensitivity,
the value range is (1~5)
DTMF Detection Sensitivity
Dial Wait Timeout (1~60sec)
Inter Digits Timeout (1~5sec)
Specify the duration of dial waiting when the
receiver is off hook. The range is 1~60 sec.
Specify the interval of input digits, if the interval is
over the setting, the system will end the dial and
send out the DTMF. The limitation range is
1~5sec.
Some SIP Proxy need specify special keyword
for FAXByPass function. Input the data as SIP
Proxy required.
FAXByPass Keyword
FAXByPass Keyword
IP Address announcement
Some SIP Proxy need specify special keyword
for FAXByPass function. Input the data as SIP
Proxy required.
You can Enable/Disable this function,
If you select Enable, you can connect T1 port
with a phone set and press #120#, you will hear
37
Download from Www.Somanuals.com. All Manuals Search And Download.
the announcement of IP address of LAN port, or
press #126# to get WAN port IP address.
FXO please following under step:
1.
You can get a PSTN line and connect to the
L1 FXO port.
2.
Use another PSTN phone to dial the PSTN
number (in step 1you connected on
FXO-08), you will hear a second dial tone
or greeting (please dial extension number).
Press #126# on the phone set, and you will
hear an IVR announcing the current IP
address of the WAN port.
3.
4.
Press #120# on the phone set, and you will
hear an IVR announcing the current IP
address of the LAN port.
System built-in music of call hold, you can
Enable/Disable this feature.
Built-in Call Hold Music
Specify the DTMF tone duration.
DTMF Duration
Specify the interval of DTMF digit
DTMF Interdigit Time
Ring Time Limit ( 10~600sec )
(FXS only)
Specify the limitation of Ring time for incoming
call, when the ring is over the limit, system will
drop the call. The default range is 10~600sec.
Specify the duration (100~1000ms) of loop
current drop, 0 for disable. This feature is used
when the SP5008A (FXS) are connected with
answering machines. When the remote site
disconnects, the system will drop FXS port’s
voltage to 0, and make the answering machines
disconnect.
Loop Current Drop Duration (0:disable,
100~1000ms )
This option is used when a stand alone relay box
containing a PSTN and FXS port is connected to
the SP5008A’s FXS port. In this special
application, if there is a network or registration
failure, the system will drop the FXS port’s
voltage to 0, when the relay box detects the
status, it will switch the line to PSTN.
FXS Voltage Drop (FXS only)
38
Download from Www.Somanuals.com. All Manuals Search And Download.
The default setting is “Disable”, if you are not
using this particular special application
mentioned above, please do not enable this
function.
Specify the IP for pinging to make sure the
network keeps alive.
ping ip to keep alive network
ping timer(sec)
Specify the interval of ping timer(sec)
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.2 SNTP Setting
Select the SNTP mode : On or Off
SNTP mode
Specify the SNTP server address for time synchronization.
Select the Time Zone of your location
SNTP server address
Time Zone -GMT
Time setting
You can specify the time with year/month/date /hour/minute
/second when you select the SNTP mode with “Off”.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.3 Codec Setting
You can specify the priority of the codec from First to Fifth (first
being the highest priority and Fifth being the lowest). You
can choose the following codec’s:
Codec Priority
z
z
z
z
z
G711U
G711A
G723
G729A
G726
You can specify the packet size in the drop down list for each
particular codec, you can choose the following:
G711U 10,20,30,40,50,60
Codec Packet Size
G711A 10,20,30,40,50,60
G723
G729A 10,20,30,40,50,60
G726 10,20,30,40,50,60
30,60,90
When you select the codec packet size shown above, system
will set default requirement of bandwidth.
Bandwidth Required
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.4 Voice Setting
Jitter Buffer
Specify the minimal delay of the jitter buffer. The range is
0~150 ms and the default setting is 0 ms.
Minimal Delay
Specify the maximal delay of the jitter buffer. The range is
0~200 ms and the default setting is 200 ms.
Maximal Delay
OPTFactor
Specify the dynamic jitter buffer frame error/delay optimization
factor, the range is 0~13.
Enable/Disable the VAD (Voice Activity Detection) feature.
This is supported on all codecs that the FXS-FXO equips.
Enable/Disable the echo cancellation feature. The default
setting is “Enable”.
VAD
Echo cancellation
Local voice volume
Remote receive volume
DTMF volume
Specify the volume gain of the voice in the local side (0~63,
default is 32). You can set this option for each of the 8 lines.
Specify the volume gain of the voice in the remote side (0~63,
default is 32). You can set this option for each of the 8 lines.
Specify the volume gain of the DTMF (0~63, default is 27).
42
Download from Www.Somanuals.com. All Manuals Search And Download.
You can set this option for each of the 8 lines.
1. Press the “Apply” button (at the bottom) after you finish to save
changes.
2. Press the “Reboot” button to apply the changes.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.5 Tone Setting
Specify the pattern of the Dial tone, you can adjust the
high frequency, low frequency, high level, low level, the
On and Off time for tone 1 and 2.
Dial tone
Specify the pattern of the Ringback tone, you can adjust
the high frequency, low frequency, high level, low level,
the On and Off time for tone 1 and 2.
Ringback tone (FXS only)
Busy tone
Specify the pattern of the Busy tone, you can adjust the
high frequency, low frequency, high level, low level, the
On and Off time for tone 1 and 2.
Specify the pattern of the call-waiting tone, you can
adjust the high frequency, low frequency, high level, low
level, the On and Off time for tone 1 and 2.
Call-waiting (FXS only)
Voice-Notify (for FXS+PSTN only)
ROH Tone (FXS only)
Specify the pattern of the Voice-Notify, you can adjust
the high frequency, low frequency, high level, low level,
the On and Off time for tone 1 and 2.
Specify the pattern of the ROH Tone, you can adjust the
high frequency, low frequency, high level, low level, the
On and Off time for tone 1 and 2. The ROH tone is a
single high frequency tone used to warn users that their
phone is not placed on-hook (hang up) correctly.
Specify the pattern of the disconnect tone for disconnect
tone 1 (first set), you can adjust the high frequency, low
frequency, high level, low level, the On and Off time for
tone 1 and 2.
Disconnect tone 1
44
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: If the disconnect tone only has single frequency,
please set it to low frequency. If the disconnect tone
only has single cadence, please set it to Tone 1.
Specify the pattern of the disconnect tone for disconnect
tone 2 (second set), you can adjust the high frequency,
low frequency, high level, low level, the On and Off time
for tone 1 and 2.
Disconnect tone 2
NOTE: If the disconnect tone only has single frequency,
please set it to low frequency. If the disconnect tone
only has single cadence, please set it to Tone 1.
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.6 Phone Setting
Primary Ringing
Specify the Ringing frequency value.
ringing frequency : 15~100 (Unit : Hz)
Specify the Ringing ON value.
Ringing Frequency
Ringing ON
Ringing OFF
Ringing level
Flash low
ringing ring ON : 0~8000 (Unit : ms)
Specify the Ringing OFF value.
ringing ring OFF : 0~8000 (Unit : ms)
Specify the ringing level.
ringing level : 0 ~ 94
(Unit : V)
Specify the value of the flash (low).
: 60~2000 (Unit : ms).
If the phone-set’s flash time is smaller than the Flash Low
setting, the flash will be ignored.
Specify the value of the flash (high).
: 60~2000 (Unit : ms)
Flash high
If the phone-set’s flash time is larger than the Flash high
setting, the flash will be handled as hang-up.
Secondary Ringing (FXS only)
Note: The feature will be enabled automatically when the Min. Digit Count has been enabled and
specified. It is used to have different ring cadence when the incoming caller number is shorter than
the setting of “Min. Digit Count”
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Specify the Ringing frequency value.
ringing frequency : 15~100 (Unit : Hz)
Specify the Ringing ON value.
Ringing Frequency
Ringing ON
ringing ring ON : 0~8000 (Unit : ms)
Specify the Ringing OFF value.
ringing ring OFF : 0~8000 (Unit : ms)
Specify the ringing level.
Ringing OFF
Ringing level
ringing level : 0 ~ 94
(Unit : V)
Specify the minimum digit count (1~10, 0: Disable), this
feature is used to change the ringing frequency by detecting
the digit length of incoming calls’ number. When the digit
length of an incoming caller number is greater than the
specified setting, the system will use primary ringing. If the
digit is less than the specified setting, the system will use the
secondary ringing.
Min. Digit Count
Specify the ringing standard to use.
Country
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.7 Digit Manipulation
This option allows users to test the digit manipulation rule
you set.
Digit Manipulation Testing
Digit Manipulation Editor
With this option, you can specify whether to add digits to a
prefix number or drop a prefix number.
For example, if the user sets:
First Example
z
z
z
Prefix: 02 (matched prefix)
Drop: Enable (drop prefix)
Insert:
If the user dials 0282265699, the resulting dial out number
will be 82265699.
Second Example
z
z
z
Prefix: 7
Drop: Disable
Insert: 886
If the user dials 778, the resulting dial out number will be
886778.
Third Example (Only applicable for SP5058A FXO)
z
z
z
Prefix: 8226
Drop: Disable
Insert: 02
If the user dials 82265699, the resulting dial out number
will be 0282265699.
You can configure up to 50 entries in the Digit
Manipulation Editor.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
For outgoing call, the default will be made to VOIP.
However, if you set the FXO prefix here, the call will be
route to FXO instead of VOIP. It can be applied to FXO
model only.
FXO Dial Prefix
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.8 Dial Plan
Using this feature, users can specify the number that will be
immediately dialed out without having to press the “#” (at the
end of the dialed number) on the keypad or until the dial time
timeout period. The number can be specified depending on
the length of the dialed number, or the prefix of the dialed
number.
Dial Plan Editor
For example, if the user sets:
First Example
z
z
z
Function: Enable
Leading digit: 02
Total Digit count: 10
If the user dials a 10 digit number with a prefix of 02 (e.g.
0282265699), the MICRONET SP5008A / SP5018A / SP5058A
will immediately detect it and dial this number straight away.
Second Example
z
z
z
Function: Enable
Leading digit:
Total digit count: 8
If the user dials an 8 digit number (e.g. 82265699), the
MICRONET SP5008A / SP5018A / SP5058A will immediately
detect it and dial this number straight away.
Third Example
z
Function: Disable
50
Download from Www.Somanuals.com. All Manuals Search And Download.
z
z
Leading digit: 02
Total digit count: 10
If the user set the Function parameter as “Disable”, the call
number with a length of 10 digits and a prefix of 02 will proceed
as normal. The user will need to wait until dial timeout period
for the call to be made, or press the “#” on the keypad at the end
of the dialing number to make the call.
You can configure up to 50 entries in the Dial Plan.
1.Press the “Apply” button (at the bottom) after you finish to save changes.
2.Press the “Reboot” button to apply the changes.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3 Management
3.3.1 Provision Server
Note: If you need this requirement, Please contact MICRONET for availabilities.
Enable/Disable provision function
Provision server Mode
Provision server IP address
Provision server port
Provision cycle time
Specify the Provision Server’s IP address.
Specify the Provision server port
Specify the cycle time of the provisioning.(unit: sec)
Specify a scheduled time in a day
Provision default time
1. Press the “Apply” button (at the bottom) after you finish to save
changes.
2. Press the “Reboot” button to apply the changes.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.2 Save-Reload setting
Click the “Export” button to export “user.cfg” data
Specify the file path and file name to Import the configure
data.
Export File
Import File
Press the “Reboot” button to apply the changes.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.3 Upgrade Firmware
Select the connection method to update the MICRONET
SP5008A/SP5018A/SP5058A’s firmware, you can choose
the following:
Download mode
z
z
TFTP
FTP
Specify the TFTP/FTP server’s IP address.
Specify the login username/password for the FTP server.
Specify the target file name for the firmware.
Specify the location of the firmware for uploading through
Http.
TFTP/FTP server IP address
FTP login
Target file name
Http Upload
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Updating the firmware by FTP
1. Select FTP mode in the drop down list.
2. Key in the IP address, login name, password of your FTP server and specify the
correct filename of the firmware.
3. Press the Start button (next to the Target file name text box) to execute the
upgrade process.
4. Please wait while the device updates itself with the firmware.
5. After the update process is finish, you will be taken to a web page indicating
that it was successful (see figure below).
6. Press the “Reboot” button to apply the changes.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Updating the firmware by TFTP
1. First, download the TFTP program from our website. Unzip the TFTP to a
directory that you desire in your hard drive and execute the TFTP program.
Make sure that the TFTP program points to the directory of where your firmware
is stored. Now, leave the TFTP program running and switch back to the
MICRONET SP5008A / SP5018A / SP5058A web configuration interface.
2. Under Device Management => Software Upgrade select TFTP mode in the
drop down list.
3. Key in the IP address of the TFTP server and specify the correct filename of the
firmware.
4. Press the Start button (next to the Target file name text box) to execute the
upgrade process.
5. Please wait while the device updates itself with the firmware.
6. After the update process is finish, you will be taken to a web page indicating
that it was successful (see figure below).
7. Press the “Reboot” button to apply the changes.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Updating the firmware by HTTP
1. Under Device Management => Software Upgrade web menu, specify the
location of the firmware by clicking the Browse button next to the Http Upload
text box.
2. You will be prompted with a window requesting the location of the firmware.
3. Locate the firmware that is stored in your hard drive.
4. Once located, click the Open button.
5. Back in the web configuration menu, press the Start button (next to the Http
Upload’s browse button) to execute the upgrade process.
6. Please wait while the device updates itself with the firmware.
7. After the update process is finish, you will be taken to a web page indicating
that it was successful (see figure below).
Note: For consistency, it is recommended to reload default setting every time you
update the firmware on the MICRONET SP5008A /SP5018A / SP5058A. However,
you will lose all the settings configured on the MICRONET SP5008A / SP5018A /
SP5058A except Network configuration. For more details on reload default setting,
please refer to the next page below.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.4 Reset to Default
Users can restore back to factory default settings using this feature. The password
of the account and the network configurations are the things that will not be
changed when this feature is executed.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.5 Network Status
Displays the current connection mode.
Connection mode
Current IP address
Subnet mask
Displays the current IP address of the WAN port.
Displays the current subnet mask’s IP.
Displays the current default gateway’s IP.
Displays the current primary DNS address.
Displays the current secondary DNS address.
Displays the MAC address of the WAN port.
Default gateway
Primary DNS address
Second DNS address
WAN MAC
59
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.6 Version Info.
Displays the current boot version loaded on the MICRONET
SP5008A / SP5018A / SP5058A.
Boot version
Displays the current post version loaded on the MICRONET
SP5008A / SP5018A / SP5058A.
Post version
Displays the current application version loaded on the
MICRONET SP5008A / SP5018A / SP5058A.
Application version
60
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.7 Port Status
Displays the corresponding port number.
Displays the status of the port.
Item
Status
Port Type
Displays the port type (FXS,FXO)of the corresponding port
number.
Displays the registration status of the corresponding port
number. if the port
Register Proxy
Register success it will display “Yes” .
61
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.8 Password
Select the type of user name that you would like to configure
the password for, you can choose the following:
Username
z
z
root
user
Specify the current password for the user selected in the drop
down list above.
Current password
New password
Specify the new password for the user selected in the drop
down list above.
Repeat the new password again for confirmation.
Confirm new password
1.
2.
Press the “Apply” button (at the bottom) after you finish to save changes.
Press the “Reboot” button to apply the changes.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4 Rebooting the system
Executing this function will reboot the whole system, when configuration changes
are made to the device, it needs to be rebooted for the changes to take effect (see
figure below).
63
Download from Www.Somanuals.com. All Manuals Search And Download.
4.Operation
4.1 Peer to Peer mode (FXO to FXS)
In this application, the distance of PABX extension is not limited. You can use the
same PABX in two or more branches.
Configuration:
1. Side A (FXO): IP address: 10.1.1.2, number is 2000 to 2008
2. Side B (FXS): IP address: 10.1.1.3, number is 1000 to 1008
Side A : (SP5058A: IP address 10.1.1.2)
General Configuration / SIP Setting
Specify the destination (Side B) IP Address of
Peer to Peer mode, and specify the port# with
5076.
Primary proxy/P2P IP
(Side A--FXO)
Call number configuration
Representative number
(Side A -- FXO)
Enable the representative line
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Side A : (SP5058A : IP address 10.1.1.2)
General Configuration / Line Setting
Line 1~Line 8
Please refer to the figure shown above, Enable
all the line and Disable all the register.
Specify the relevant data: Account, number,
password and display name.
(Side A -- FXO)
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Side B: (MICRONET SP5008A : IP address 10.1.1.3)
General Configuration—SIP Setting
Specify the destination (Side A) IP Address of
Primary proxy/P2P IP
(Side B)
Peer to Peer mode, and specify the port# with
5076
Call number configuration
Representative number
(Side B)
Enable the representative line
Line 1~Line 8
Please refer to the figure shown above, Enable
all the line and Disable all the register.
Specify the relevant data: Account, number,
password and display name.
(Side B)
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Side B: (MICRONET SP5008A: IP address 10.1.1.3)
General Configuration / Line Setting
Line 1~Line 8
(Side B)
Please refer to the figure shown above, Enable
all the line and Disable all the register and call
waiting.
Specify the relevant data: Account, number,
password and display name
1. Press the “Apply” button (at the bottom) after you finish to save changes.
2. Press the “Reboot” button to apply the changes.
67
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 Peer to Peer mode (FXS to FXS)
Peer A—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address
is: 192.168.23.14)
Peer B—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address
is: 192.168.23.58)
Peer A—MICRONET SP5008A / SP5018A / SP5058A ( for example the IP address
is: 192.168.23.14)
68
Download from Www.Somanuals.com. All Manuals Search And Download.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Peer B—MICRONET SP5008A / SP5018A / SP5058A (for example the IP
address is: 192.168.23.58)
70
Download from Www.Somanuals.com. All Manuals Search And Download.
Specify the destination IP Address of Peer to
Peer mode, and specify the port# with 5076.
In this application, we define the Peer to Peer
mode in 2 groups. If you want to make call
to others IP addresses, please refer to the
paragraph 3.3.7 Speed dial setting.
Primary proxy/P2P IP
(Peer A / Peer B)
Call number configuration
Representative number
(Peer A / Peer B)
Enable the representative line
Line 1~Line 8
Please refer to the figure shown above, Enable
all the line and Disable all the register of two
sides.
(Peer A / Peer B)
Specify the relevant data: Account, number,
password and display name.
3. Press the “Apply” button (at the bottom) after you finish to save changes.
4. Press the “Reboot” button to apply the changes.
71
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Specification
Model
SP5008A
Standard
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and Secondary
Outbound Proxy
8 FXS
POTS Interface
Ethernet Port
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M
4 x RJ-45 LAN ports of 10/100M
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A
VAD, CNG, and Silence Suppression
Echo Cancellation (G.165 / G.168)
Adaptive Jitter Buffer
Voice
Packet Loss Compensation
Adjustable volume level
DTMF
In-band, SIP Info, RFC2833
Telephony
z
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)
Call hold, Call transfer, Call waiting, Call forward (Unconditional, No
answer, Busy, No Answer+Busy)
z
z
z
z
z
z
z
z
Music on Hold
Hotline and Waiting Time to Hotline
Speed Dial and Peer-to-Peer Call
Anonymous Call
DND (Do Not Disturb)
Dial Plan and Digit Manipulation
Tone Generation/Detection: Ringing Tone, Ring Back Tone, Dial Tone,
Programmable Tone
z
z
z
z
z
z
z
z
z
z
z
CDR (Call Detail Record)
MWI (Message Waiting Indication)
FAX over IP: G.711 pass-through, T.38 Fax relay
Representative number setting
PBX Features
Support SIP Trunk
Extension calling among FXS ports
Direct line (DID) to extension
Max. 9 registrars (SIP trunk and 8 direct lines)
Operator (Serial ring on extension) for attendant
HTTP 1.1 basic/digest authentication for WEB access
MD5 for SIP authentication (RFC 2069/2617)
Security
72
Download from Www.Somanuals.com. All Manuals Search And Download.
z
z
z
z
z
z
Password protected for Admin access authority
PPPoE Client, DHCP Client / Server, NAT, SNTP
QoS: DiffServ / ToS
Networking
Management
User interface: HTTP and Telnet
Firmware upgrade via FTP/TFTP/HTTP/Telnet
Auto Provisioning
Environment
z
z
z
z
Operating Temperature: 0 – 45 degree C
Storage Temperature: 0 – 55 degree C
Operating Humidity: 10 to 85% (non-condensing)
Storage Humidity: 10 to 95% (non-condensing)
Power Supply
Emission
DC 12V, 3A
CE
FCC Part 15, Class B
Model
SP5018A
Standards
z
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and
Secondary Outbound Proxy
Interface
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M
4 x RJ-45 LAN ports of 10/100M
4 x RJ-11 FXS ports for connecting with phone set and fax machine
4 x RJ-11 FXO ports for connecting with PSTN line or PABX’s extension
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A
VAD, CNG, and Silence Suppression
Voice Processing
Echo Cancellation (G.165 / G.168)
Adaptive Jitter Buffer
Packet Loss Compensation
Adjustable volume level
DTMF relay: In-band, RFC 2833, SIP Info
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)
Call hold
Call Features
Call transfer (blind & consultant)
Call forward (Unconditional, No answer, Busy)
MWI (Message Waiting Indication)
FAX over IP: G.711 pass-through, T.38 Fax relay
PSTN Lifeline: PSTN bypass if network or system fails
Detection of disconnect tone, polarity reversal, and loop current drop (zero
voltage) on FXO ports
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Security
z
z
z
z
z
z
z
z
z
z
z
z
z
HTTP 1.1 basic/digest authentication for WEB access
MD5 for SIP authentication (RFC 2069/2617)
Password protected for Admin access authority
PPPoE Client, DHCP Client / Server, NAT, SNTP
QoS: DiffServ / ToS
Networking
Management
User interface: HTTP and Telnet
Firmware upgrade via FTP/TFTP/HTTP/Telnet
Auto Provisioning
Power Supply
Environment
DC 12V, 3A
Operating Temperature: 0 – 45 degree C
Storage Temperature: 0 – 55 degree C
Operating Humidity: 10 to 85% (non-condensing)
Storage Humidity: 10 to 95% (non-condensing)
35 × 242 × 160 (mm)
Dimension
Emission
z
z
CE
FCC Part 15, Class B
Model
SP5058A
Standards
z
SIPv2 (RFC 3261): Primary and Secondary Proxy, Primary and Secondary
Outbound Proxy
Interface
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
1 x RJ-45 WAN port of 10/100M
4 x RJ-45 LAN ports of 10/100M
8 x RJ-11 FXO ports for connecting with PSTN line or PABX’s extension
Codec: G.711a/mu-law, G.723.1 (6.3K), G.729, G.729.A
VAD, CNG, and Silence Suppression
Voice Processing
Echo Cancellation (G.165 / G.168)
Adaptive Jitter Buffer
Packet Loss Compensation
DTMF relay: In-band, RFC 2833, SIP Info
Caller ID Detection: FSK, DTMF, ETSI (before ringing, between ringing)
Call hold
Call Features
Call transfer (blind & consultant)
Call forward (Unconditional, No answer, Busy)
FAX over IP: G.711 pass-through, T.38 Fax relay
Detection of disconnect tone, polarity reversal, and loop current drop (zero
voltage) on FXO ports
Security
z
HTTP 1.1 basic/digest authentication for WEB access
74
Download from Www.Somanuals.com. All Manuals Search And Download.
z
z
z
z
z
z
z
z
z
z
z
z
MD5 for SIP authentication (RFC 2069/2617)
Password protected for Admin access authority
PPPoE Client, DHCP Client / Server, NAT, SNTP
QoS: DiffServ / ToS
Networking
Management
User interface: HTTP and Telnet
Firmware upgrade via FTP/TFTP/HTTP/Telnet
Auto Provisioning
Power Supply
Environment
DC 12V, 3A
Operating Temperature: 0 – 45 degree C
Storage Temperature: 0 – 55 degree C
Operating Humidity: 10 to 85% (non-condensing)
Storage Humidity: 10 to 95% (non-condensing)
35 × 242 × 160 (mm)
Dimension
Emission
z
z
CE
FCC Part 15, Class B
75
Download from Www.Somanuals.com. All Manuals Search And Download.
|