NEC Car Video System MD211G3 User Manual

MD211G3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
1
3/27/12 11:18:27 AM  
Manufacturer’s Recycling and Energy Information  
NEC DISPLAY SOLUTIONS is strongly committed to environmental protection and sees recycling as one of the company’s  
top priorities in trying to minimize the burden placed on the environment. We are engaged in developing environmentally-  
friendly products, and always strive to help define and comply with the latest independent standards from agencies such as  
ISO (International Organisation for Standardization).  
Disposing of your old NEC product  
The aim of recycling is to gain an environmental benefit by means of re-use, upgrading, reconditioning or reclamation of  
material. Dedicated recycling sites ensure that environmentally harmful components are properly handled and securely  
disposed. To ensure the best recycling of our products, NEC DISPLAY SOLUTIONS offers a variety of recycling procedures  
and gives advice on how to handle the product in an environmentally sensitive way, once it has reached the end of its life.  
All required information concerning the disposal of the product and country-specific information on recycling facilities can be  
found on our following websites:  
Energy Saving  
This monitor features an advanced energy saving capability. When a VESA Display Power Management Signalling (DPMS)  
Standard signal is sent to the monitor, the Energy Saving mode is activated. The monitor enters a single Energy Saving mode.  
Mode  
Power consumption  
Approx. 105 W  
Less than 2 W  
LED colour  
Green  
Normal Operation  
Energy Saving Mode  
Off Mode  
Amber  
Less than 1 W  
Unlit  
WEEE Mark (European Directive 2002/96/EC)  
Within the European Union  
EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic  
products carrying the mark (left) must be disposed of separately from normal household waste. This includes  
monitors and electrical accessories, such as signal cables or power cords. When you need to dispose of your  
NEC display products, please follow the guidance of your local authority, or ask the shop where you purchased  
the product, or if applicable, follow any agreements made between yourself and NEC.  
The mark on electrical and electronic products only applies to the current European Union Member States.  
Outside the European Union  
If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority  
so as to comply with the correct disposal method.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
3
3/27/12 11:18:29 AM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
4
3/27/12 11:18:29 AM  
Index  
Warning, Caution..........................................................................................................................English-2  
Intended Use................................................................................................................................English-3  
Recommended use ......................................................................................................................English-4  
Contents.......................................................................................................................................English-6  
Quick Start....................................................................................................................................English-7  
Controls........................................................................................................................................English-10  
Specifications ...............................................................................................................................English-12  
Symbol Information  
This symbol warns user that uninsulated voltage within the unit may have sufficient magnitude to  
cause electric shock. Therefore, it is dangerous to make any kind of contact with any part inside  
this unit.  
This symbol alerts the user that important literature concerning the operation and maintenance of  
this unit has been included. Therefore, it should be read carefully in order to avoid any problems.  
Protective earth terminal marked.  
Main switch ON.  
Main switch OFF.  
AC Input.  
MEDICAL - GENERAL MEDICAL EQUIPMENT  
UL MARK CERTIFICATION, ANSI/AAMI ES60601-1:2005  
cUL, CAN/CSA-C22.2 NO.60601-1:08  
AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL  
HAZARD ONLY IN ACCORDANCE WITH ANSI/AAMI  
ES60601-1:2005 AND CAN/CSA-C22.2 NO.60601-1:08  
ALSO LISTED ACCORDANCE WITH UL 60950-1 AND  
CAN/CSA-C22.2 NO.60950-1-07  
45VU  
E332883  
Windows is a registered trademark of Microsoft Corporation. NEC is a registered trademark of NEC Corporation.  
ErgoDesign is a registered trademark of NEC Display Solutions, Ltd. in Austria, Benelux, Denmark, France,  
Germany, Italy, Norway, Spain, Sweden, U.K.  
All other brands and product names are trademarks or registered trademarks of their respective owners.  
The DisplayPort Icon is a trademark of the Video Electronics Standards Association, registered in the U.S.  
and other countries.  
English-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
1
3/27/12 11:18:29 AM  
WARNING  
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT  
USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE  
PRONGS CAN BE FULLY INSERTED.  
REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE. REFER SERVICING  
TO QUALIFIED SERVICE PERSONNEL.  
CAUTION  
TO REDUCE THE RISK OF ELECTRIC SHOCK, MAKE SURE POWER CORD IS UNPLUGGED FROM WALL SOCKET. TO  
FULLY DISENGAGE THE POWER TO THE UNIT, PLEASE DISCONNECT THE POWER CORD FROM THE AC OUTLET.  
DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED  
SERVICE PERSONNEL.  
Power Cord Important Information  
CAUTION: Please use the power cord provided with this monitor in accordance with the table below. If a power cord is not  
supplied with this equipment, please contact your supplier. For all other cases, please use a power cord that matches the  
AC voltage of the power outlet and has been approved by and complies with the safety standard of your particular country.  
When you use this monitor in North America, you should use a North America Hospital Grade power cord.  
European  
Continental  
Plug Type  
North America  
U.K.  
Chinese  
Japanese  
Plug Shape  
(green dot  
and tag label)  
Country  
Voltage  
U.S.A./Canada  
120  
EU (except U.K.)  
230  
U.K.  
230  
China  
220  
Japan  
100  
NOTE:  
This product can only be serviced in the country where it was purchased.  
English-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
2
3/27/12 11:18:30 AM  
Intended Use  
The MD211G3 Grayscale display is intended to be used for displaying and viewing of digital images for diagnosis by trained  
physicians.  
To guarantee the display performance as specified, it must only be used in conjunction with NEC approved display controllers.  
MD211G3 cannot be used for a life-support system.  
This device must not be used in digital mammography.  
This device is designed for exclusive interconnection with IEC60601-1-1 certified equipment.  
Contraindications: None known.  
Safety Precaution  
The unit is designed for exclusive interconnection with IEC60950 certified equipment outside of patient environment and IEC  
60601-1 certified equipment inside the patient environment.  
Equipment connected to digital interfaces must comply with the respective IEC standards (e.g. IEC 60950 for data  
processing equipment and IEC 60601-1 for medical equipment).  
This device complies with EN60601-1-2. To minimize the interference from other equipment, a minimum 0.5 m distance shall  
be kept form other potential electromagnetic sources, such as a cell phone.  
To reduce the risk of electric shock, make sure the power cord is unplugged from the wall socket. To fully disengage  
the power to the unit, please disconnect the power cord from the ac outlet. Do not remove the front or back cover. No  
user serviceable parts inside. Refer servicing to qualified service personnel. The AC outlet shall be readily available and  
accessible.  
This device uses temperature-controlled fans for internal cooling. The use of this device in surgery rooms is not recommended if  
cleaning of the air intakes from dust and textile lint in regular time intervals cannot be performed by the user (maximum interval:  
six months).  
This device is equipped with an integrated front sensor and ambient light sensor complying with the IEC 62563-1 standard  
requirements for measurement devices with a calibration traceable to a primary standards laboratory. Therefore, these sensors  
can be re-calibrated using external luminance and illuminance meters as a reference, which were calibrated following country  
specific legal obligations for metrological control. When re-calibrated in a regular manner, the integrated front sensor and  
ambient light sensor may then be used for remote quality assurance following the IEC 62563-1 standard. NEC Display Solutions  
recommends to check the integrated front sensor and ambient light sensor intervals of two (2) years.  
North America Customers  
Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked “Hospital Only”  
or “Hospital Grade”. That signal input port need to be connected properly and that any unused signal input port shall not be  
accessible for the patient to contact in the patient area after the LCD is integrated into a medical system.  
Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner.  
European Customers  
Unpacking, installation and calibration of this monitor must only be done by authorized and trained personnel. Any installation  
done by a non-authorized person is done under his own risk and we accept no responsibility in any device malfunctioning.  
Medical Imaging  
MD211G3 is designed for 1536 x 2048 (portrait mode) or 2048 x 1536 (landscape mode) medical imaging.  
English-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
3
3/27/12 11:18:30 AM  
Recommended use  
Safety Precautions and Maintenance  
FOR OPTIMUM PERFORMANCE, PLEASE  
NOTE THE FOLLOWING WHEN SETTING UP  
AND USING THE LCD MONITOR:  
WARNING: Do not modify this equipment without authorization of the manufacturer.  
WARNING: To disconnect this product from the mains supply disconnect the mains plug from the socket outlet.  
WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.  
WARNING: No modification of this equipment is allowed.  
WARNING: For EMC details information, please contact NEC local authority.  
DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose  
you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel.  
Do not spill any liquids into the cabinet or use your monitor near water.  
Do not insert objects of any kind into the cabinet slots, as they may touch dangerous voltage points, which can be harmful or  
fatal or may cause electric shock, fire or equipment failure.  
Do not place any heavy objects on the power cord. Damage to the cord may cause shock or fire.  
Do not place this product on a sloping or unstable cart, stand or table, as the monitor may fall, causing serious damage to  
the monitor.  
The power supply cord you use must have been approved by and comply with the safety standards of your country.  
(Type H05VV-F 3G 1mm2 should be used in Europe).  
In UK, use a BS-approved power cord with molded plug having a black (5A) fuse installed for use with this monitor.  
Do not place any objects onto the monitor and do not use the monitor outdoors.  
The lamps in this product contain mercury. Please dispose according to state, local or federal law.  
Do not bend power cord.  
Do not use monitor in high temperatured, humid, dusty, or oily areas.  
Temperature controlled fans are implemented in this monitor. For reliable performance and long useful life of this product, it  
is mandatory to not cover any vents on the monitor.  
Vibration can damage the backlight. Do not install where the monitor will be exposed to continual vibration.  
If monitor or glass is broken, do not come in contact with the liquid crystal and handle with care.  
To prevent damage to the LCD monitor caused by tipping over due to earthquakes or other shocks, make sure to install the  
monitor in a stable location and take measures to prevent falling.  
Please do not touch patient and this medical device at the same time.  
Immediately turn off the power, unplug your monitor from the wall outlet and move to a safe location then refer servicing to  
qualified service personnel under the following conditions. If the monitor is used in this condition, the monitor may cause fall, fire  
and electric shock:  
If the monitor stand has been cracked or peeled.  
If the monitor has been wobbled.  
If the monitor has an unusual odor.  
When the power supply cord or plug is damaged.  
If liquid has been spilled, or objects have fallen into the monitor.  
If the monitor has been exposed to rain or water.  
If the monitor has been dropped or the cabinet damaged.  
If the monitor does not operate normally by following operating instructions.  
Allow adequate ventilation around the monitor so that heat can properly dissipate. Do not block ventilated  
openings or place the monitor near a radiator or other heat sources. Do not put anything on top of monitor.  
The power cable connector is the primary means of detaching the system from the power supply.  
The monitor should be installed close to a power outlet which is easily accessible.  
CAUTION  
Handle with care when transporting. Save packaging for transporting.  
Do not touch LCD panel surface while transporting, mounting and setting.  
Applying pressure on the LCD panel can cause permanent damage.  
Carry the monitor holding the built-in handle and bottom frames of the monitor.  
Do not carry holding only the stand.  
This monitor has a front sensor. Do not touch the front sensor while carrying the monitor. Do not apply any  
stress to the front sensor.  
This device uses temperature-controlled fans for internal cooling. The use of this device in surgery rooms  
is not recommended if cleaning of the air intakes from dust and textile lint in regular time intervals cannot  
be performed by the user (interval: max. six months).  
English-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
4
3/27/12 11:18:30 AM  
Image Persistence: When a residual or “ghost” image of a previous image remains visible on the screen, this is called image  
persistence. Unlike CRT monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for  
a long period of time should be avoided.  
To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an image  
was on the monitor for one hour and a residual image remains, the monitor should be turned off for one hour to erase the image.  
NOTE: As with all personal display devices, NEC DISPLAY SOLUTIONS recommends using a moving screen saver at regular  
intervals whenever the screen is idle or turning off the monitor when not in use.  
Maintenance:  
a) Before first use of this monitor for diagnostic imaging, an initial calibration to DICOM Part 14 is highly recommended.  
To ensure constant visual quality over the life of this monitor, the recommended time interval to re-calibrate this model is  
12 months.  
b) This model is equipped with an integrated front sensor and ambient light sensor complying with the IEC 62563-1 standard  
requirements for measurement devices with a calibration traceable to a primary standards laboratory. Therefore, these sensors  
can be re-calibrated using external luminance and illuminance meters as a reference, which were calibrated following country  
specific legal obligations for metrological control. When re-calibrated in a regular manner, the integrated front sensor and  
ambient light sensor may then be used for remote quality assurance following the IEC 62563-1 standard. NEC Display Solutions  
recommends to re-calibrate the integrated front sensor and ambient light sensor latest after 2 years, whichever comes first.  
CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN  
REDUCE EYE, SHOULDER AND NECK FATIGUE. CHECK THE  
FOLLOWING WHEN YOU POSITION THE MONITOR:  
For optimum performance, allow 30 minutes for the monitor to warm up.  
Adjust the monitor height so that the top of the screen is at or slightly below eye level.  
Your eyes should look slightly downward when viewing the middle of the screen.  
Position your monitor no closer than 40 cm (15.75 inches) and no further away than  
70 cm (27.56 inches) from your eyes. The optimal distance is 50 cm (19.69 inches).  
Rest your eyes periodically by focusing on an object at least 20 feet away. Blink often.  
Position the monitor at a 90° angle to windows and other light sources to minimize glare  
and reflections. Adjust the monitor tilt so that ceiling lights do not reflect on your screen.  
Avoid displaying fixed patterns on the monitor for long periods of time to avoid image  
persistence (after-image effects).  
Get regular eye checkups.  
NOTE:  
This model is set up in the factory so that the NEC logo is briefly displayed after the monitor is powered on.  
This feature can be turned on or off in the Advanced OSD.  
In case you find such bright Brand Logo annoying in your reading room environment, you may easily switch this off.  
By keeping the “EXIT” button pressed while this logo is displayed, the BOOT LOGO menu will appear. It is possible to  
change the BOOT LOGO setting to OFF.  
Cleaning the LCD Panel  
When the LCD is dusty, please gently wipe with a soft cloth.  
Please do not rub the LCD panel with hard or coarse material.  
Please do not apply pressure to the LCD surface.  
Please do not use OA cleaner as it will cause deterioration or discoloration on the LCD surface.  
Cleaning the Cabinet  
Unplug the power supply  
Gently wipe the cabinet with a soft cloth  
To clean the cabinet, dampen the cloth with a neutral detergent and water, wipe the cabinet and follow with a dry cloth.  
NOTE:  
Many plastics are used on the surface of the cabinet. DO NOT clean with benzene, thinner, alkaline detergent,  
alcoholic system detergent, glass cleaner, wax, polish cleaner, soap powder, or insecticide. Do not touch rubber or  
vinyl to the cabinet for a long time. These types of fluids and fabrics can cause the paint to deteriorate, crack or peel.  
English-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
5
3/27/12 11:18:31 AM  
Contents  
Your new NEC monitor box* should contain the following:  
MD211G3 monitor with tilt/swivel/pivot/height adjust stand  
Power Cord  
Video Signal Cable (DVI-D to DVI-D cable)*1  
DisplayPort cable  
USB Cable  
Quick Reference Guide  
CD-ROM x 2  
Power Cord*2  
CD-ROM x 2  
Quick Reference Guide  
USB Cable  
DVI-D to DVI-D cable*1  
DisplayPort cable  
*
*
*
Remember to save your original box and packing material to transport or ship the monitor.  
1
2
Dual link DVI cable.  
Type and number of power cords included will depend on the where the LCD monitor is to be shipped. When more than one power cord is  
included, please use a power cord that matches the AC voltage of the power outlet and has been approved by and complies with the safety  
standard of your particular country.  
English-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
6
3/27/12 11:18:31 AM  
Quick Start  
To connect the LCD monitor to your system, follow these instructions:  
NOTE:  
Make sure to read “Recommended Use” before installation.  
In order to display the maximum resolution, a display controller that can output a resolution of 1536 x 2048 (in portrait  
mode) or 2048 x 1536 (in landscape mode) is needed.  
1. Turn off your computer.  
2. For a PC with DVI digital output: Connect the DVI signal cable to the connector of the display controller in your system  
(Figure A.1). Tighten all screws.  
For a PC with DisplayPort output: Connect the DisplayPort cable to the connector of the display controller in your system  
(Figure A.2).  
DisplayPort cable  
Figure A.1  
Figure A.2  
NOTE:  
1. Please use a DisplayPort cable with a DisplayPort logo.  
2. When removing the DisplayPort cable, hold down the top button to release the lock.  
3. Height adjustment is locked by a lock button. Place hand on top of the monitor stand to push down the screen to the lowest  
position. Slide the lock button to unlock (Figure B.1).  
NOTE:  
Handle with care when unlocking the stand.  
Place hands on each side of the monitor to tilt the LCD panel to a 30-degree tilt angle and lift up to the highest position.  
Slide the cable cover up (Figure B.2).  
NOTE:  
The cable cover is not removable.  
30° Tilt  
Cable cover  
Figure B.1  
Figure B.2  
English-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
7
3/27/12 11:18:31 AM  
4. Connect all cables to the appropriate connectors (Figure C.1). When using the USB cable, connect the B type connector  
to the USB upstream port on the right back side of the monitor and the A type connector to the downstream port on the  
computer (Figure C.1a). If using the cord from a USB device, plug into one of the downstream ports of the monitor.  
NOTE:  
Incorrect cable connections may result in irregular operation, damage display quality/components of the LCD module  
and/or shorten the module’s life.  
NOTE:  
Up to 5 sub monitors can be daisy-chained.  
30° Tilt  
A Type  
A Type  
B Type  
Highest  
Stand  
Power cord  
Position  
B Type  
DVI-D Cable  
DisplayPort Cable  
Figure C.1a  
USB Upstream Port  
USB Downstream Port  
Sensor Port*1  
Figure C.1  
5. To keep the cables neatly organized, place them into the cable management system that is built into the stand.  
Place the cables in the hooks firmly and evenly (Figure C.2 and Figure C.3).  
6. Please check that you can still rotate, raise and lower the monitor screen when you have installed the cables.  
Power Cord  
DVI-D Cable  
Power Cord  
DVI-D Cable  
DisplayPort Cable  
USB Cable  
USB Cable  
DisplayPort  
Cable  
Figure C.2  
Figure C.3  
*1 Connect the optional USB optical sensor to this port for self calibration. (See page 25, CD-ROM Version)  
English-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
8
3/27/12 11:18:31 AM  
7. Slide down the cable cover (Figure D.1).  
8. Connect one end of the power cord to the AC inlet on the back of the monitor and the other end to the power outlet.  
NOTE:  
Please refer to the Caution section of this manual for proper selection of an AC power cord.  
Figure D.1  
9. Turn on the monitor with power switch on the top (Portrait) or left side (Landscape) of the monitor (Figure E.1). Turn on the  
computer.  
NOTE:  
If you have any problems, please refer to the Troubleshooting section of this User’s Manual (CD-ROM Version).  
Power switch  
Figure E.1  
English-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb  
9
3/27/12 11:18:32 AM  
Controls  
OSD (On-Screen Display) control buttons on the front of the monitor  
function as follows:  
To access the OSD menu, press the EXIT button. To change the signal input, press the SELECT button.  
All buttons are located at the back of the monitor.  
The Key Guide appears pressing any button when not in the OSD control menu.  
NOTE:  
The OSD must be closed in order to change the signal input.  
4
5
6
1
2
3. Control Buttons  
E
D
C
B
A
1 KEY GUIDE  
The Key Guide appears on the screen when the OSD control menu is accessed.  
The Key Guide will rotate when the OSD control menu is rotated.  
Perform along the notification of each key.  
NOTE: The KEY GUIDE appears as follows:  
• KEY GUIDE when OSD menu is displayed.  
• KEY GUIDE when HOT KEY is set to OFF.  
• KEY GUIDE when HOT KEY is set to ON.  
Each KEY GUIDE works as follows:  
- Exits any OSD sub menu.  
Exits the OSD Control menu.  
- Shows OSD menu.  
- Shows PICTURE MODE.  
- Selects the item.  
- Changes the input source.  
- Resets the OSD back to factory settings.  
- Shows the quick screen QA test pattern.  
Indicates that power is on.  
A. RESET button  
2 LED  
3 Control Buttons  
NOTE: When not in the OSD control menu, press the RESET button for at least 3 seconds  
to display the quick screen QA test pattern (grayscale) drawing and check the display  
performance.  
B. SELECT button  
C.UP/DOWN button  
D.LEFT/RIGHT button  
E. EXIT button  
4 AMBIENT LIGHT Sensor Detects the level of ambient light, allowing the monitor to make adjustments to various  
settings. Do not cover this sensor (See page 17, CD-ROM Version).  
5 FRONT SENSOR  
Detects screen luminance changes over time.  
Used for luminance stabilization, standalone (Self Calibration, Gamma Adjust, DICOM  
Measurement) and network (Gamma Adjutst, DICOM Measurement) controlled calibrations  
and conformance tests.  
6 SENSOR PORT  
For optional external sensor used for self calibration and copy calibration.  
English-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb 10  
3/27/12 11:18:32 AM  
SETTING OSD LANGUAGE  
Set the OSD language before using OSD functions.  
Use the control keys (LEFT/RIGHT or UP/DOWN or EXIT) to access the “LANGUAGE SELECTION” menu.  
Press the LEFT/RIGHT or UP/DOWN buttons to select the desired OSD language.  
To exit from this OSD menu, press the EXIT button.  
NOTE:  
Setting the OSD language is only necessary upon initial setup. The OSD language will stay the same until changed  
by the user.  
For OSD menu or Advanced OSD menu, see CD-ROM Version.  
English-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb 11  
3/27/12 11:18:33 AM  
Specifications  
Monitor Specifications  
MD211G3 Monitor  
Notes  
LCD Module  
Diagonal: 54.0 cm/21.3 inches  
Viewable Image Size: 54.0 cm/21.3 inches  
Native Resolution (Pixel Count): 1536 x 2048 (Portrait)  
2048 x 1536 (Landscape)  
Active matrix; thin film transistor (TFT) liquid crystal  
display (LCD); SA-SFT (IPS) 0.212 mm dot pitch;  
1450 cd/m2 max luminance; 400 cd/cm2 calibrated  
luminance; 900:1 contrast ratio (typical).  
Input Signal  
DisplayPort:  
DisplayPort Connector: Digital RGB  
DVI-D 24pin: Digital RGB  
DisplayPort Complies with Standard V1.1a,  
applicable to HDCP  
DVI:  
DVI  
Display Tones  
10bit: 1024 (10bit) shades of gray from a  
When used with a NEC approved 10bit display  
pallet of 48961 (15.5bit)  
controller  
8bit: 256 (8bit) shades of gray from a pallet of  
48961 (15.5bit)  
When used with a NEC approved 8bit display  
controller  
Synchronization Range  
Horizontal: 31.5 kHz to 99.4 kHz, 126.3 kHz  
Vertical: 30 Hz, 50 Hz to 85 Hz  
Automatically  
Automatically  
Clock Frequency  
Viewing Angle  
214.3 MHz (Max)  
Left/Right: ±88° (CR > 10)  
Up/Down: ±88° (CR > 10)  
Image Formation Time  
27 ms (Typ.)  
13 ms (Gray to gray Typ)  
Resolutions Supported (Some systems may  
not support all modes listed).  
640 x 480*1 at 60 Hz to 85 Hz  
720 x 400*1 at 70 Hz to 85 Hz  
800 x 600*1 at 56 Hz to 85 Hz  
1024 x 768*1 at 60 Hz to 85 Hz  
1280 x 1024*1 at 60 Hz to 85 Hz  
1600 x 1200*1 at 60 Hz to 75 Hz  
1920 x 1200*1 at 60 Hz  
2048 x 1536 at 30 Hz to 60 Hz (Reduced Blanking)  
2048 x 1536 at 60 Hz (Reduced Blanking)...........NEC DISPLAY SOLUTIONS recommended resolution  
1024 x 1280 at 60 Hz*1  
1200 x 1600 at 60 Hz*1  
for optimal display performance.  
1536 x 2048 at 60 Hz (Reduced Blanking)...........NEC DISPLAY SOLUTIONS recommended resolution  
for optimal display performance.  
Active Display Area  
USB Hub  
Landscape: Horiz.: 433.2 mm/17.1 inches  
Vert.: 324.9 mm/12.8 inches  
Portrait: Horiz.: 324.9 mm/12.8 inches  
Vert.: 433.2 mm/17.1 inches  
I/F: USB Specification Revision 2.0  
Port: Upstream 1  
Downstream 2  
Load Current: Maximum 0.5A per port  
Power Supply  
Current Rating  
Dimensions  
AC 100-240 V ~ 50/60 Hz  
1.2 - 0.46 A  
For Mexico 2.0A  
Landscape: 467.8 mm (W) x 377.6 - 527.6 mm (H) x 227.6 mm (D)  
18.4 inches (W) x 14.9 - 20.8 inches (H) x 9.0 inches (D)  
Portrait: 361.6 mm (W) x 483.4 - 580.7 mm (H) x 227.6 mm (D)  
14.2 inches (W) x 19.0 - 22.9 inches (H) x 9.0 inches (D)  
Height Adjustment: 150 mm/5.9 inches  
Weight  
10.7 kg (23.6 lbs)/Without stand: 7.5 kg (16.5 lbs)  
Sensor Accuracy and Repeatability  
Front Sensor  
Accuracy: +/-10% (Lv>10cd/m2), +/-1cd/m2 (10cd/m2 Lv>2cd/m2), +/-0.5cd/m2 (Lv 2cd/m2)  
Repeatability: +/-2%  
(Standard Deviation)  
Ambient Sensor  
Accuracy: +/-10%  
(Light source: Fluorescent Lamp, Distance: 58 cm,  
Angle: 25 +/-5 degrees from the vertical axis of the  
ambient sensor).  
Repeatability: +/-5%  
(Same as Accuracy conditions).  
Environmental Considerations  
Operating Temperature: 5°C to 35°C/41°F to 95°F  
Humidity: 30% to 80%  
Altitude: -1,246 to 9,842 Feet/-380 to 3,000 m  
Atmospheric pressure: 700hPa to 1060hPa  
Transport/Storage Temperature: -10°C to 60°C/14°F to 140°F  
Humidity: 10% to 85%  
Altitude: -1,246 to 39,370 Feet/-380 to 12,000 m  
Atmospheric pressure: 200hPa to 1060hPa  
At 25 degrees, Target Brightness 400cd/m2  
*1 Interpolated Resolutions: When resolutions are shown that are lower than the pixel count of the LCD module, text may appear different. This is normal and  
necessary for all current flat panel technologies when displaying non-native resolutions full screen. In flat panel technologies, each dot on the screen is actually one  
pixel, so to expand resolutions to full screen, an interpolation of the resolution must be done.  
NOTE:  
Technical specifications are subject to change without notice.  
English-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb 12  
3/27/12 11:18:33 AM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb 13  
3/27/12 11:19:14 AM  
NEC Display Solutions, Ltd.  
4-28, Mita 1-chome, Minato-ku, Tokyo,  
Japan  
NEC Display Solutions of America, Inc. NEC Display Solutions Europe GmbH  
500 Park Blvd. Suite 1100 Itasca,  
Illinois 60143  
Landshuter Allee 12-14  
D-80637 Muenchen  
Germany  
USA  
Phone: 630.467.3000  
Fax: 630.467.3010  
Phone: +49(0)89/99699-0  
Fax: +49(0)89/99699-500  
1st Edition, April 2012  
Printed in China  
Part No. 1E507781  
Printed on recycled paper  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MD211G3 paper manual.indb 14  
3/27/12 11:19:14 AM  

Miele Washer W 460 WPS User Manual
Nady Systems Portable Stereo System RPA6 User Manual
Navigon GPS Receiver 2090S User Manual
NETGEAR Switch FS524 User Manual
NHT Speaker CS 61 Ci User Manual
Niles Audio Stereo Receiver SCW 1D User Manual
NorthStar Navigation Portable Radio 710 VHF User Manual
Numark Industries CD Player AXIS 8 Premium User Manual
Onkyo Stereo System HT S6100 User Manual
Panasonic Telephone KX TC1025ALW User Manual