Preparation before use
Before using the air conditioner, be sure to check and preset the following.
Remote Controller presetting
The remote controller is NOT presetting correctly for cooling and reverse cycle.
Each time after replacing the batteries in the remote controller, the Cooling indicator
and
Heating indicator
will flashes alternately on LCD of the remote controller.
User can preset the remote controller type depending on the air conditioner type you have purchased
as follows:
Press any button when
Press any button when
flashes, Heat Pump is set.
flashes, Cooling Only is set.
If you don't press any button within 12 seconds, the remote controller is preset to Heat Pump automatically.
Note:
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it will not
operate. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only,
then you CAN NOT preset the Heating operation with the remote controller.
Auto Restart Presetting
If you want auto restart function, hold down the Emergencybutton (ON/OFF) on the indoor unit for over 5
seconds, auto restart function is set with a buzz sound, air conditioner is on standby.
If auto restart has been set, hold down the Emergency button (ON/OFF) on the indoor unit for over 5
seconds, auto restart function is canceled with buzz sound, air conditioner is on standby.
Safety precautions
Symbols in this User Manual are interpreted as shown below.
Be sure not to do.
Grounding is essential.
Warning: Incorrect handling could
cause a serious hazard, such as death,
serious injury, etc.
Pay attention to such a situation.
ON
Use correct power supply in
accordance with the rating plate
requirement. Otherwise, serious
faults or hazard may occur or a
fire maybe break out.
OFF
Do not use the power supply circuit
breaker or pull off the plug to turn it off
during operation. This may cause a fire
Prevent the air flow from reaching the gas
burners and stove.
due to spark, etc.
Never insert a stick or similar obstacle
to the unit. Since the fan rotates at high
speed, this may cause an injury.
Do not touch the operation buttons
when your hands are wet.
Do not put any objects on the outdoor
unit.
Do not repair the appliance by yourself.
If this is done incorrectly, it may cause an
electric shock, etc.
Turn off the appliance by remote control
firstly before cutting off power supply if
malfunction occurs.
2
Identification of parts
Indoor unit
Air Intake
Front Panel
Display Panel
Emergency Panel
Air Outlet
Vertical Adjustment
Louver
Horizontal Adjustment
Louver
Air Filter
Remote Controller
Air Intake
Outdoor unit
Pipes and Power
Connection Cord
Drain Hose
Note: Condensate water drains
at COOLING or DRY operation.
Air Outlet
The figures in this manual are based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have selected.
Note: The pipes and power connection cord will be provided or purchased by customer.
3
Identification of parts
UH series operating and Display
Timer Indicator
Run Indicator
It is on during operation.
It flashes during
defrosting.
It lights up during the
set time.
Tim er
Comp.
Run
Slee p
Sleep Indicator
Compressor indicator
Temperature display
It lights up when
unit is in sleep mode.
Display actual room
temperarure.
Display set temperature.
It lights up when
compressor is running.
.
The shape and position of the switches and indicators may vary from different models, but their function are similar.
4
Remote controller
Remote controller
The remote controller transmits signals to the system.
ON/OFF BUTTON
1
MODE BUTTON
2
3
FAN BUTTON
ROOM TEMPERATURE
SETTING BUTTONS
4
4
SWING BUTTON
5
6
S UP ER
S MAR T
9
6
2
5
SMART BUTTON
3
8
7
1
TIMER SET/CANCEL BUTTON
7
8
SLEEP BUTTON
SUPER BUTTON
9
Indication symbols on LCD:
See page 9 "Smart Mode"
for details)
Note: Ea ch mo de and relevant function will be furthe r spec ified in following pa ges.
Remote controller
Remote controller
How to Insert the Batteries
Remove the battery cover according to the arrow direction.
Insert new batteries making sure that the (+) and (-) of
battery are matched correctly.
Reattach the cover by sliding it back into position.
Note:
Use 2 LR03 AAA(1.5volt) batteries. Do not use rechargeable batteries.
Replace batteries with new ones of the same type when the display
becomes dim or effective responce.
If the replacement is done within 1 minute, the remote controller
will keep original presetting. However, if you want to change the
presetting from Heat Pump to Cool Only or Cool Only to Heat Pump,
you should reload batteries 3 minutes after removing the old ones.
(Please refer to page 1 for details.)
Storage and Tips for Using the Remote Controller
The remote controller may be stored mounted on a wall with a holder.
Note: The remote controller holder is an optional part.
Remote controller holder
How to Use
To operate the room air conditioner, aim
the remote controller to the signal receptor.
The remote controller will operate the air
conditioner at a distance of up to 7m when
pointing at signal receptor of indoor unit.
Signal receptor
Choose Cooling Only Remote controller or Heat Pump
Please refer to page 1 " Preparation before use" for details.
Back-light Function (optional)
Please refer to page 1 "Preparation before use" for details.
6
Operation instructions
Operation modes
Selecting mode
Each time MODE button is pressed, the operation mode
is changed in sequence:
COOLING
DRY
FAN ONLY
HEATING
Heating mode is NOT available for cooling only air conditioner.
FAN mode
Each time the "FAN" button is pressed, the fan speed is
changed in sequence:
High
Medium
Auto
Low
At "FAN ONLY" mode, only "High","Medium" and "Low" are available.
At "DRY" mode, airflow is set at "Low" automatically, "FAN" button
is ineffective in this case.
Setting temperature
SUPER
SMART
Press once to raise temperature setting by 1℃
Press once to lower temperature setting by 1℃
1
3
Range of available set temperature
SLEEP
2
*HEATING, COOLING
DRY
18 ~32
room temperature
2
+
-
unable to set
ONLY
FAN
*Note: Heating mode is NOT available for cooling only models.
4
Turning on
Press
button, when the appliance receives the
signal, the RUN indicator of the indoor unit lights up.
SWING, SMART, TIMER, SLEEP and SUPER operation modes will be specified in the following pages.
Changing modes during operation, sometimes the unit does not response at once. Wait 3 minutes.
During heating operation, air flow is not discharged at the beginning. After 2-5 minutes, the air flow will be discharged
until temperature of indoor heat exchanger rises.
Wait 3 minutes before restarting the appliance.
7
Operation instructions
Airflow direction control
Airflow direction control
Vertical airflow is automatically adjusted to a certain angle
in accordance with the operation mode after turning on the unit.
The direction of airflow can be
Operation mode Direction of airflow
also adjusted to your own
requirement by pressing the
"SWING" button of the
remote controller.
SUPER
SMART
5
horizontal
downward
COOLING, DRY
*HEATING,
FAN ONLY
5
SLEEP
*Heating mode is only available for heat pump models.
Vertical airflow control (with the remote controller)
Using remote controller to set various angles of flow or specific angle
as you like.
Swinging airflow
Pressing "SWING" button once, the vertical adjustment
louver will swing up and down automatically.
Desired direction airflow
Pressing the "SWING" button again when the louvers swing
to a suitable angle as desired.
Horizontal airflow control (with hands)
Turning the control rods of the
horizontal adjustment louvers to
change horizontal air flow as shown.
Note: The shape of the unit may look different
from that of the air conditioner you have selected.
control rods of horizontal
adjustment louvers
Do not turn the vertical adjustment louvers manually, otherwise malfunction may occur. If that happens, turn off the unit
first and cut off the power supply, then restore power supply again.
It is better not to let the vertical adjustment louver tilt downward for a long time at COOLING or DRY mode to prevent
condensed water from dripping.
8
Operation instructions
SMART mode
Press the SMART button, the unit enters smart mode(fuzzy logic operation) directly regardless of
the unit is on or off. In this mode, temperature and fan speed are automatically set based on the
actual room temperature.
Operation mode and temperature are determined by indoor temperature
Heat pump models
Target temperature
Operation mode
HEATING
DRY
Indoor temperature
21℃ or below
21℃-26℃
22℃
Room temperature
decrease 1.5℃ after
operate for 3 minutes
COOLING
Over 26℃
26℃
Cooling only models
Indoor temperature
SM ART
SU P ER
Operation mode
Target temperature
Room temperature
decrease 1.5℃ after
operate for 3 minutes
DRY
26℃ or below
SLEEP
Over 26℃
COOLING
26℃
SMART button is ineffective in SUPER mode.
Note: Temperature, airflow and direction are controlled automatically in SMART mode.
However, a decrease or rise of up to 2 ℃ can be set with the remote controller if you still
feel uncomfortable.
A decrease or increase up to 2℃ can be set in SMART mode
Your feeling
button
adjustment procedure
High
Low
High
Press once to lower the
Slightly warmer
set temp by 1
℃
A decrease up
to 2℃ can be set
Press twice to lower the
set temp by 2
℃
Low
High
Low
High
Press once to raise the
set temp by 1
Slightly cooler
℃
A rise up to
2℃ can be set
Press twice to raise the
set temp by 2℃.
Low
Uncomfortable
because of
unsuitable air
Indoor fan speed alternates among
High, Medium and Low each time this
button is pressed.
flow volume.
Press it once, the vertical adjustment
louver swings to change vertical airflow
direction. Press it again, swings stops.
For horizontal airflow direction, please
refer to the previous page for details.
Uncomfortable
because of
unsuitable flow
direction.
9
Operation instructions
Timer mode
It is convenient to set the timer on with TIMER button when you go out in the morning
to achieve a comfortable room temperature at the time you get home. You can also set
timer off at night to enjoy a good sleep.
Timer-setting
Setting a switch-on
timer when the
appliance is off.
Setting a switch-off timer
during operation.
SU PER
SM AR T
2
As time goes by, LCD on remote controller only displays the remained time instead of
set temperature.
2
SLEEP
The previous set time is stored and the next set time begins with the previous setting.
On- timer and off-timer can not be set at the same time.
1
The room may not reach your desired temperature within the preset time because of
different size of room.
Example: set an operation after 9.5 hours
Set desired operating mode, temperature setting and indoor fan speed firstly,
then press the TIMER button and "h" flashes on LCD.
1
Point the remote control at the signal receptor of the indoor unit,
press the or button when "h" flashes. Choose the timer you want ,
then press the TIMER button.
A "beep" can be heard.
2
3
Timer indicator on the indoor unit lights up.
"h" stops flashing.
Press the TIMER button, "h" flashes on the LCD, then you can set the time.
Each time the or button is pressed,
If the desired time is within 10 hours, the set time increases or decreases by 0.5 hour;
If desired time is beyond 10 hours, increases or decreases by 1 hour.
The range can be set is 0.5 hour to 24 hours.
To cancel the set timer: press the TIMER button again, a "beep" can be heard
and the timer indicator on the indoor unit swithes off.
10
Operation instructions
SLEEP mode
SLEEP mode
SLEEP mode can be set in COOLING or HEATING operation mode.
This function gives you a more comfortable environment for sleeping.
In SLEEP mode,
The appliance will stop operation automatically after operating for 8 hours.
Fan speed is automatically set at low speed.
*Set temperature will rise by 1℃ at most if the appliance operates in cooling
mode for 2 hours constantly, then keeps steady.
Set temperature will decrease by 3℃ at most if the appliance operates in
SU PE R
SM ART
heating mode for 3 hours constantly, then keeps steady.
*Note: In cooling mode, if room temperature is 26℃or above, set temperature
will not change.
Note: Heating is NOT available for cooling only air conditioner.
SLEEP
SUPER mode
SUPER mode
SUPER mode is used to start or stop fast cooling.
Fast cooling operates at high fan speed, changing the set temperature
℃
automatically to 18 .
SUPER mode can be set when the appliance is in operation or energized.
In SUPER mode, you can set airflow direction or timer. If you want to
escape from SUPER mode, press any -SUPER, MODE, FAN, ON/OFF
or TEMPERATURE SETTING button, the display will return to the original
PER
SMART
1
mode.
Note:
SLEEP and SMART buttons are not available in SUPER mode.
SUPER button is ineffective in HEATING mode.
SLEEP
The Appliance will continue working in SUPER mode with set temperature of 18℃, if
you don't escape from it by pressing any of the buttons mentioned above.
.
11
Maintenance
Front panel maintenance
Air filter maintenance
Cut off the power supply
It is necessary to clean the air filter
after using it for about 100 hours.
Turn off the appliance
first before disconnecting
from power supply.
Clean it as follows:
a
Stop the appliance and remove
the air filter.
Grasp position "a" and
pull outward to remove the
front panel.
a
1
2
3
Wipe with a soft
and dry cloth.
1.Open the front panel.
2.Press the handle of the filter gently
from the front.
3. Grasp the handle and slide out the filter.
Use a dry and
Use lukewarm water
(below 40℃) to clean
if the appliance
is very dirty.
soft cloth to
clean it.
Never use volatile substance
such as gasoline or polishing
powder to clean the appliance.
Clean and reinstall the air filter.
If the dirt is conspicuous,
wash it with a solution of
detergent in lukewarm water.
After cleaning, dry well in
shade.
Never sprinkle water onto the
indoor unit
Close the front panel again.
Reinstall and shut the front panel.
Clean the air filter every two weeks
if the air conditioner operates in an
extremely dusty environment.
Reinstall and shut the front panel by
pressing position "b" downward.
b
b
12
Protection
Noise pollution
Operating condition
The protective device maybe trip and stop
the appliance in the cases listed below.
Install the air conditioner at a place that
can bear its weight in order to operate
more quietly.
Outdoor air temperature is over 24oc
Outdoor air temperature is below -7oc
Install the outdoor unit at a place where
the air discharged and the operation noise
would not annoy your neighbors.
HEATING
Room temperature is over 27oc
Outdoor air temperature is over *50oc
COOLING
Room temperature is below 21oc
Do not place any obstacles in front of the
air outlet of the outdoor unit lest it increases
the noise level.
Room temperature is below 18oc
DRY
*For Tropical (T3) Climate condition models, the
temperature point is 52℃ instead of 43℃.
If the air conditioner runs in COOLING or DRY mode with
door or window opened for a long time when relative
humidity is above 80%,dew may drip down from the outlet.
Features of protector
The protective device will work at following cases.
Restarting the unit at once after operation stops or changing mode during operation, you need to
wait 3 minutes.
Connect to power supply and turn on the unit at once, it may start 20 seconds later.
If all operation has stopped, press ON/OFFbutton again to restart, Timer should be set again
if it has been canceled.
Features of HEATING mode
Preheat
At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5
minutes later.
Defrost
In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.
After defrosting completes, it returns to HEATING mode automatically.
Note: Heating is NOT available for cooling only air conditioner models.
13
Troubleshooting
The following cases may not always be a malfunction, please check it before asking for service.
Trouble
Analysis
If the protector trip or fuse is blown.
Please wait for 3 minutes and start again,
protector device may be preventing unit to work.
Does not run
.
If batteries in the remote controller exhausted.
If the plug is not properly plugged.
Is the air filter dirty?
Are the intakes and outlets of the air
conditioner blocked?
No cooling or
heating air
Is the temperature set properly?
If strong interference(from excessive static
electricity discharge, power supply voltage
abnormality)presents, operation will be
Ineffective control
abnormal. At this time, disconnect from the
power supply and connect back 2-3 seconds later.
Does not operate
immediately
Changing mode during operation, 3 minutes
will delay.
It is not
working
This odour may come from another source
such as furniture, cigarette etc, which is
sucked in the unit and blows out with the air.
Peculiar odour
Caused by the flow of refrigerant in the
air conditioner, not a trouble.
A sound of
flowing water
Defrosting sound in heating mode.
The sound may be generated by the expansion
or contraction of the front panel due to change
of temperature.
Cracking sound is
heard
Mist appears when the room air becomes
very cold because of cool air discharged
from indoor unit during COOLING or DRY
operation mode.
Spray mist from
the outlet
The unit is shifting from heating mode to defrost.
The indicator will lights off within ten minutes and
returns to heating mode.
The compressor indicator(red) lights on constantly,
and indoor fan stops.
14
Installation instructions
Installation diagram
Distance from ceiling
should be over 50 mm
Distance from wall
should be over 50mm
Distance from the wall
should be over 50mm
Distance from floor
should be over 2000mm
Air intake distance from the wall
should be over 250mm
Air intake distance from
the wall should be
over 250mm
over 250mm
Above figure is only a simple presentation
of the unit, it may not match the external
appearance of the unit you purchased.
Installation must be performed in accordance with
the national wiring standards by authorized personnel only.
15
Installation instructions
Location for Installing Indoor Unit
Where there is no obstacle near the air outlet and air can be
easily blown to every corner.
Indoor unit
Where piping and wall hole can be easily arranged.
Keep the required space from the unit to the ceiling and wall
according to the installation diagram on previous page.
Where the air filter can be easily removed.
Keep the unit and remote controller 1m or more apart from
television, radio etc.
Pipe length is
15 meters Max.
To prevent the effects of a fluorescent lamps, keep as far as
possible.
Outdoor unit
Do not put anything near the air inlet to obstruct it from air
absorption.
Where there is strong enough to bear the weight
and is not tend to increase operation noise and vibration.
Location for Installing Outdoor Unit
Outdoor unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
Pipe length is
15 meters Max.
The distance between Indoor and outdoor unit should
be 5 meters and can go up to maximum 15 meters
with additional refrigerant charge.
Keep the outdoor unit away from a place of greasy dirt,
vulcanization gas exit.
Avoid installing it at the roadside where there is a risk of
muddy water.
A fixed base where is not subject to increasing operation
noise.
Where there is not any blockage for air outlet.
Indoor unit
Max. Allowable Tubing
Length at Shipment (m)
Limit of Tubing
Length (m)
Limit of Elevation
Difference H (m) additional refrigerant (g/m)
Required amount of
Model
24K
5
15
5
20
16
Installation instructions
Indoor unit installation
1. Installing the Mounting Plate
Decide an installing location for the mounting plate according to the indoor unit location and piping direction.
Keep the mounting. plate horizontally with a horizontal ruler or dropping line.
Drill holes of 32mm in depth on the wall for fixing the plate.
Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
Inspect if the mounting plate is well fixed. Then drill a hole for piping.
Line drops from here
Hook the line here
Mounting plate
Dropping line
holes for fixing
Note: The shape of your mounting plate may be different from the one above, but installation method is similar.
2. Drill a Hole for Piping
Wall hole sleeve
Decide the position of hole for piping according to the
( hard polythene tube
location of mounting plate.
prepared by user)
Drill a hole on the wall. The hole should tilt a little
downward toward outside.
5mm
(tilt downward)
Install a sleeve through the wall hole to keep the wall
tidy and clean.
3. Indoor Unit Piping Installation
Put the piping (liquid and gas pipe) and cables through the wall hole from outside or put them through
from inside after indoor piping and cables connection complete so as to connect to outdoor unit.
Decide whether saw the unloading piece off in accordance with the piping direction.(as shown below)
Piping direction
trough
Unloading
piece
4
1
3
Note: When installing the pipe at the directions
1,2 or 4, saw the corresponding unloading piece
off the indoor unit base.
Saw the unloading piece
off along the trough
2
After connecting piping as required, install the drain hose. Then connect the power cords. After connecting,
wrap the piping, cords and drain hose together with thermal insulation materials.
17
Installation instructions
Piping Joints Thermal Insulation:
Wrap the piping joints with thermal
insulation materials and then wrap
with a vinyl tape.
wrapped with vinyl type
Thermal insulation
Piping Thermal Insulation:
Large pipe
Thermal insulation
a. Place the drain hose under the piping.
tube
b. Insulation material uses polythene foam over 6mm in thickness.
Power connecting cord
Note: Drain hose is prepared by user.
Small
pipe
Drain pipe should point downward for easy drain flow.
Do not arrange the drain pipe twisted, sticking out or wave
around, do not immerse the end of it in water.
If an extension drain hose is connected to the drain pipe, make
sure to thermal insulated when passing along the indoor unit.
Drain hose
(prepared by user)
When the piping is directed to the right, piping, power
Cord and drain pipe should be thermal insulated and
fixed onto the back of the unit with a piping fixer.
Insert here
large
pipe
large
pipe
drain
hose
drain
small
small
pipe
hose
pipe
Hook here
Base
Piping fixer
Base
Piping fixer
Base
A. Insert the pipe fixer to the slot.
B. Press to hook the pipe fixer onto the base.
Piping Connection:
a. Connect indoor unit pipes with two wrenches. Pay special attention
to the allowed torque as shown below to prevent the pipes, connectors
and flare nuts from being deformed and damaged.
b. Pre-tighten them with fingers at first, then use the wrenches.
Min.thickness
Model
24K
24K
Pipe size
Liquid Side (3/8 inch)
Gas Side (5/8 inch)
Torque Nut width
22mm
27mm
0.6mm
0.6mm
3.5kg.m
7.5kg.m
Note: The connection pipe will be provided or purchased by customer.
18
Installation instructions
4. Connecting of the Cable
Front panel
Terminal (inside)
Indoor Unit
Connect the power connecting cord to the indoor unit
by connecting the wires to the terminals on the control
board individually in accordance with the outdoor unit
connection.
Cabinet
Chassis
Indoor unit
Note: For some models, it is necessary to remove the cabinet to
connect to indoor unit terminal.
Outdoor Unit
1). Remove the access door from the unit by loosening
the screw. Connect the wires to the terminals on the
control board individually as the following.
2). Secure the power connecting cord onto the control
board with cable clamp.
Access door
Terminal(inside)
3). Reinstall the access door to the original position
with the screw.
Outdoor unit
4) Use a recognized circuit breaker for 24K model between
the power source and the unit. A disconnecting device to
adequately disconnect all supply lines must be fitted.
The figures in this manual are based on the external
view of a standard model. Consequently, the shape
may differ from that of the air conditioner you have
selected.
Caution:
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, refer to the circuit diagram posted on the inside of the access door .
2.Comfirm that the cable thickness is as specified in the power source specification.
(See the cable specification table below)
3.Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in wet or moist area.
Cable Specifications
Power cord
Power connecting cord
Capacity
(Btu/h)
Normal cross
- sectional area
Normal cross
- sectional area
Type
Type
2.5mm2X3
1.0mm2X3
H07RN-F
H07RN-F
24K
Note: The cable will be provided or purchased by customer.
Attention:
Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect
it in case of need. If not possible, connect appliance to a double-pole switching device with contact
separation of at least 3 mm placed in an accessible position even after installation.
19
Installation instructions
Wiring Diagram
Make sure that the color of wires of the outdoor unit and the terminal No. are the same as those
of the indoor unit.
24K Model
For 24K model, the power supply are connected from outdoor unit, with a circuit breaker.
HEAT PUMP
Indoor unit
Outdoor unit
Terminal
Terminal
Black
Black
Power connecting cord
3
3
Brown
Brown
Blue
2
1
2
1
L
N
Power supply
20
Installation instructions
Outdoor unit installation
1.Install Drain Port and Drain Hose (for heat-pump model only)
The condensate drains from the outdoor unit when the unit operates
in heating mode. In order not to disturb your neighbor and protect
the environment, install a drain port and a drain hose to direct the
condensate water. Just install the drain port and rubber washer to
the chassis of the outdoor unit, then connect a drain hose to the
port as the right figure shown.
Washer
Drain port
Drain hose
(prepare by user)
2. Install and Fix Outdoor Unit
Fix with bolts and nuts tightly on a flat and strong floor.
If installed on the wall or roof, make sure to fix the supporter well to prevent it
from shaking due to serious vibration or strong wind.
3. Outdoor Unit Piping Connection
Remove the valve caps from the 2-way and 3-way valve.
Connect the pipes to the 2-way and 3-way valves separately according to the required torque.
4. Outdoor Unit Cable Connection (see previous page)
Air purging
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the
compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant
cycle using a vacuum pump, as shown below.
Note: To protect the environment, be sure not to discharge the refrigerant to the air directly.
See next page for air purging steps.
Vacuum pump
indoor unit
Refrigerant flow direction
2-way valve
3-way valve diagram
3-way valve
connect to indoor unit
(6) Open 1/4 turn
(7) Turn to fully open the valve
valve cap
open position
spindle
(7) Turn to fully open the
valve
Service
port
(1) Turn
(8) Tighten
(1) Turn
(8) Tighten
(2) Turn
(8) Tighten
needle
Valve cap
Connect to outdoor unit
Valve core
service port cap
21
Installation instructions
How to Purge Air Tubes:
(1). Unscrew and remove caps from 2 and 3-way valves.
(2). Unscrew and remove cap from service valve.
(3). Connect vacuum pump flexible hose to the service valve.
(4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes.
(5). With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop
vacuum pump.
(6). Open 2-way valve 1/4 turn then close it after 10 seconds. Check tightness of all joints using liquid
soap or an electronic leak detector.
(7). Turn 2 and 3-way valves stem to fully the valves. Disconnect vacuum pump flexible hose.
(8). Replace and tighten all valve caps.
Notes
Please read this manual before installing and using it.
Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.
Testing run the air conditioner after finishing installation, and record details of operation.
Type of fuse used on indoor unit controller is 50T, with rating 3.15A,AC250V. .
The fuse for the whole unit is to be provided by the user according to the current at maximum power
Input or use other over-current protective device instead.
Only the air conditioner can be connected to the power line.
The power connection for the air conditioner has to be done at the main power distribution which has
to be of a low impedance.
In order to ensure the suitability of the equipment for connection, the user should consult with the
supply authority, if necessary, that the service current capacity at the interface point is sufficient
for the equipment.
Refer to the rating plate of the equipment for power consumption details.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or
similarly qualified person in order to avoid a hazard.
22
NEC Australia Pty. Ltd
ABN 86 001 217 527
Home Electronics Group
NEC Service Centres
NEW South Wales
Sydney
184 Milperra Rd, Revesby 2212
120 Parry Street, Newcastle 2302
(02) 9780 8688
(02) 4926 2466
Newcastle
Victoria
Melborne
480 Princes Highway, Noble Park 3174 (03) 9554 6245
Queensland
Brisbane
Southport
116 Ipswich Rd, Woollongabba 4102
Shop 1, 48 Ferry Rd, Southport 4215
(07) 3361 5858
(07) 5591 3670
South Australia
Adelaide
84A Richmond Rd, Keswick, 5053
(08) 8375 5710
Western Australia
Perth
45 Sarich Courl, Osborne Park 6017
(08) 9445 5901
For Service in outer areas, please contact your
of the nearest Authorized NEC Service Centre.
retailer for the address
NEC Australia Pty. Ltd.
244 Beecroft Road EPPING 2121
Tel. 131- 632 Fax. (02) 9930 2380
Version No. 819043175-01
|