Mustang Survival Life Jacket MD3188 User Manual

MANUfAcTURER'S MANUAL  
MD3188  
United States coast Guard Approvals:  
- Type V Work Vest  
- Type V Uninspected Commercial Vessels  
- Type II Recreational PFD  
INfLATAbLE PERSONAL fLOTATION DEVIcE  
DO NOT REMOVE PRIOR TO SALE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cONTENTS  
Introduction .............................................................................................................................1  
United States Coast Guard Approvals .....................................................................1  
Approval Conditions and Carriage Regulations .......................................................................2  
Conditions for Commercial Type V and/or Work Vest Approval in Commercial  
Applications ...........................................................................................................2  
Mandatory Carriage Requirements .........................................................................3  
Note to Commercial Vessel Operators.....................................................................3  
What is an Inflatable PFD? ......................................................................................................3  
Instructions for Use..................................................................................................................3  
Commercial Vessel Use ..........................................................................................3  
Visual Inspection Instructions and Readiness Checklist .........................................4  
Donning Instructions ..............................................................................................5  
Removal Instructions...............................................................................................6  
Inflating Your Inflatable PFD ...................................................................................6  
Usage Below Freezing ............................................................................................8  
Deflating the Inflatable PFD....................................................................................8  
Re-arming Your PFD ................................................................................................8  
Repacking Your PFD ..............................................................................................11  
Is Your PFD in Good and Serviceable Condition?..................................................13  
Servicing Instructions for Commercial Operators ..................................................13  
Care and Maintenance instructions ......................................................................13  
Commercial Training Content and Procedure.........................................................................17  
Use........................................................................................................................17  
Maintenance .........................................................................................................17  
Service Record and Inspection Log Procedure.......................................................19  
Why are PFDs Required Safety Equipment?...........................................................................20  
How and Why to Test Your PFD.............................................................................20  
Hypothermia ..........................................................................................................................22  
How Hypothermia Affects Most Adults .................................................................23  
Each of These Devices is Intended to Help You Save Your Life..............................24  
Inflatable PFD Safety Accessories..........................................................................24  
Additional information...........................................................................................................24  
Do Not Attach PFDs to Your Boat..........................................................................24  
Airline Operator Policy on Carriage of Inflatable PFDs and CO Cartridges..........24  
2
Glossary.................................................................................................................................25  
ii  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUcTION  
This manual provides instructions and guidelines for safely using and maintaining the  
Mustang Survival MD3188 Inflatable Personal Flotation Device (PFD). It is strongly  
recommended that users familiarize themselves with all the procedures presented in this  
manual.  
Full gear in-water testing is recommended to validate performance and to become familiar  
with the use and feel of the PFD.  
The MD3188 PFD provides flotation, helping to keep the head above water, to stay face up,  
and to increase chances for survival and rescue. The PFD inflates automatically on submersion  
using a hydrostatic inflator that significantly reduces the potential for accidental inflation due  
to humidity, sea spray, or wet storage. The inflator must be submerged to activate.  
The MD3188 PFD may also be inflated manually, prior to submersion, by pulling the manual  
inflation handle.  
The MD3188 PFD is designed to offer maximum mobility with minimum bulk. The MD3188  
PFD is worn as a comfortable, slim collar that can be inflated at any time either automatically  
(water immersion), manually (manual inflation handle), or orally (oral inflation tube).  
Drowning is the leading cause of fatalities involving recreational and commercial vessels.  
Most fatal accidents happen on calm sunny days, and in approximately 80 percent of all  
boating fatalities, the victims were not wearing a PFD.  
When worn, used, and serviced according to the instructions in this manual, Mustang Survival  
MD3188 PFDs can greatly increase a user's chance of survival in the water.  
United States coast Guard Approvals  
Type V work vest  
Type V uninspected commercial vessels  
Type II recreational PFD  
1
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPROVAL cONDITIONS AND cARRIAGE  
REGULATIONS  
Commercial Vessels – Model MD3188 is approved by the U.S. Coast Guard (USCG) as a  
Work Vest ONLY WHEN WORN under 46 CFR 160.053 for use on all inspected and uninspected  
commercial vessels of any length. Not approved for “Hot Work”.  
Uninspected Commercial Vessels – Model MD3188 is USCG-approved for use in  
lieu of a Type II PFD under 46 CFR 160.064 on uninspected commercial vessels less than 40  
feet in length not carrying passengers for hire as a substitute for a Type II PFD when used and  
serviced in accordance with this manufacturer’s manual.  
conditions for commercial Type V and/or Work Vest  
Approval in commercial Applications  
1. The MD3188 must be worn before getting underway and whenever above deck and not  
within an enclosed space to meet the carriage requirement.  
2. The operator of a commercial vessel is responsible for servicing and maintaining the  
MD3188 in good serviceable condition in accordance with this manufacturer’s manual.  
See Care and Maintenance Instructions (page 13) for servicing information.  
3. The operator of a commercial vessel is responsible for providing each person onboard  
with the safety information required for use of the MD3188. See Note to Commercial  
Vessel Operators, page 3, for information.  
4. All inflatable PFDs in use aboard a commercial vessel must be the same manufacturer  
and model or have the same method of operation. Hydrostatic inflation and pill or  
bobbin type inflation do not qualify as the same method of operation.  
Recreational Boats – Model MD3188 is approved by the USCG for use as a Type II  
Personal Flotation Device (PFD). It is not approved for water skiing or other high impact, high  
speed activities. This inflatable PFD was designed to be more comfortable and less restrictive  
to wear than inherently buoyant PFDs. When worn, used, and serviced according to this  
manufacturer's manual, this PFD can greatly increase your chances of survival in the water.  
Not recommended for non-swimmers or weak swimmers. Users of  
inflatable PFDs must be at least 16 years old.  
General – When fully inflated, this Inflatable PFD will provide Type II in-water performance.  
This Inflatable PFD will turn most wearers from a face down to a face up position and provide  
support suitable for offshore conditions. This PFD must be in good and serviceable condition  
including properly armed with a full CO cylinder, inflation system status indicator, and an  
2
accessible manual inflation lanyard.  
2
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mandatory carriage Requirements  
Federal regulations in 33 CFR 175-1993 require you to carry USCG-approved personal  
flotation devices (PFDs) legibly marked with the USCG-approval number which are in good  
and serviceable condition and are the correct size for each person on board. To be considered  
serviceable, this PFD shall not exhibit deterioration that could diminish its performance such  
as broken or deformed hardware, detached webbing, rotted structural components, air leaks,  
or nonfunctional oral inflation tube. This PFD must also be properly armed with a full CO  
2
cylinder, inflation system status indicator, and an accessible manual inflation lanyard. A PFD  
which is "approved only when worn" or "required to be worn" must be worn under the  
specified conditions.  
Note to commercial Vessel Operators  
The operator of the vessel must note that this PFD is NOT approved for use by passengers  
and is advised to tell passengers which PFDs are and are not suitable for their use during any  
passenger safety orientation (reference 46 CFR 26.03-1 and 46 CFR 122.506).  
WhAT IS AN INfLATAbLE PfD?  
While traditional PFDs are inherently buoyant, inflatable PFDs rely entirely on inflation for  
buoyancy. Uninflated, this Inflatable PFD is a comfortable slim collar that can be inflated at  
any time with a 33-gram CO gas cylinder. The Inflatable PFD is designed to offer maximum  
2
mobility with minimum bulk. The Inflatable PFD can be inflated either automatically by water  
immersion, manually by jerking a pull-tab, or orally by mouth. It is recommended that you  
familiarize yourself with the procedures outlined in Instructions for Use (page 3).  
INSTRUcTIONS fOR USE  
This manual supplies instructional, maintenance and safety information for model MD3188.  
The PFD model number is listed on the underside label.  
commercial Vessel Use  
This Inflatable PFD is not approved for “hot work”. Although the outer cover in the packed  
condition is resistant to abrasion and puncture, care must be taken to avoid damage from  
heat, abrasion, and sharp objects.  
3
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual Inspection Instructions and Readiness checklist  
Before each use, perform a visual inspection and ensure each check box is checked.  
Figure 1  
F
Check that the single point status indicator is green.  
Examine the single point status indicator through the window panel of the  
hydrostatic inflator (Figure 1 and 2). Ensure the indicator is green. If the indicator is  
red, the mechanism has been fired or is incorrectly fitted (see Re-arming Your PFD,  
page 8).  
NOTE: The single point status indicator  
must be green before proceeding.  
Hydrostatic Inflator Cap  
Water Inlet Valve  
F
F
F
Check that the current date is not past the date on  
the inflator.  
Black Locking Ring  
Yellow Inflator Cap  
Cap/Locking Ring  
If the current date is past the date on the  
inflator, replace the inflator (see Re-arming Your  
PFD, page 8).  
Single  
Point  
Lanyard  
Status  
Inflator  
Body  
Check that the oral tube dust cap is in the stowed  
position (Figure 7).  
Expiry  
Date  
Manual Inflation  
Pull-tab  
To access the oral tube, use the Velcro™ tab  
(Figure 1) to undo the zipper on the wearer’s left  
side and unfold the inflatable cell.  
Figure 2  
Check for damage to the device.  
Check for rips, tears, excessive abrasion, fading, or holes.  
Check the seams for secure attachment.  
Check the cell cover, straps, and hardware for strength.  
Ensure the hardware is not deformed.  
If the device shows damage, it may need servicing or replacement.  
4
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F
F
Check that the inflation pull-tab is hanging on the outside (Figure 32).  
If the pull-tab is not hanging on the outside, see Repacking Your PFD, page 11.  
Check that all zippers, Velcro™ and waist buckle are securely fastened.  
If zippers are opened, repack the device according to Repacking Your PFD, page 11.  
Put on the inflatable PFD (see Donning Instructions, page 5).  
F
Check that the inflatable PFD is not twisted.  
Feel the device around your neck to ensure it is not twisted.  
Your Inflatable PFD is ready for use if all boxes are checked.  
NOTE: contact your Mustang dealer if you have any concerns about the  
readiness of your Inflatable PfD.  
Sizing and fit  
This PFD provides a minimum of 33.7 lbs (150 N) of buoyancy when inflated and is designed  
for wearers over 16 years of age, with a chest range of 30-52 inches (76-132 cm) weighing  
over 80 pounds (36 kg).  
Donning Instructions  
It is important that the Inflatable PFD is properly adjusted to fit the person wearing it. An  
incorrect fit or improper fastening of attachments could impede its effectiveness.  
1. All belts and straps are already threaded correctly and only need to be adjusted for fit.  
The belt should fit below your rib cage, adjusted to a tight personal fit.  
2. Put the Inflatable PFD on just like a jacket (Figure 3) and fasten the front buckle.  
Figure 3  
WARNING: LOOSE VEST OR LOOSE ENDS cAN kILL OR MAIM yOU.  
5
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To secure loose ends:  
3. Adjust the waist belt for a snug fit using the side buckle on the belt.  
4. Reposition the plastic sliding loop as far back as possible to keep the free end from  
hanging loose.  
5. Wrap and tuck any remaining loose strap around belt.  
6. Recheck loose ends and readjust as needed.  
WARNING: Do not wear Inflatable PfDs under clothing as the inflation  
could be restricted or you could be injured.  
Removal Instructions  
In some instances, quick removal of the PFD may be necessary for your safety.  
Simply unfasten the front buckle, and remove the vest like a jacket.  
In-water removal of your PFD may require deflation through the oral tube to access and open  
the front buckle (see Deflating the Inflatable PFD, page 8).  
Inflating your Inflatable PfD  
It is recommended that the following procedures be  
followed to inflate your Inflatable PFD:  
1. Manual Inflation – Activate the inflation system  
by jerking firmly downward on the pull-tab (Figure  
4). The Inflatable PFD should fully inflate within 5  
seconds.  
2. Automatic Backup Inflation – When  
the inflator is lowered more than about  
4 inches in the water, then the hydrostatic valve opens  
and lets the water meet the water sensitive element  
that in turn releases a stainless steel coil spring. The  
spring then drives a needle into the end of the gas  
cylinder, which is now punctured so that the gas  
instantly fills the life jacket. Total buoyancy is normally  
Figure 4  
reached within 4-5 seconds.  
Permeation Loss Information  
Permeation loss is greater when the PFD is inflated with carbon dioxide (CO gas) than with  
2
air. When inflated, the CO gas used to inflate the PFD will slowly escape through the fabric  
2
over time. A slight reduction of pressure will be observed after several hours of inflation.  
Topping up by oral inflation may be required in the event of prolonged immersion.  
6
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Oral Inflation – Properly armed and inspected  
Inflatable PFDs will inflate when manually or  
automatically activated. However, you can fully inflate  
the Inflatable PFD by mouth (Figure 5) should inflation  
not occur, or if you are in a non-emergency situation.  
To orally inflate the Inflatable PFD in a non-emergency  
situation:  
i.  
Ensure the cylinder body and inflator cap are  
properly installed.  
ii. Open both of the zippers (2) starting from the  
Velcro™ Tab (Figure 1).  
Figure 5  
iii. Locate the oral inflation tube by opening the  
wearer’s left front panel of the Inflatable PFD.  
iv. Remove the dust cap from the end of the oral tube and blow into the tube until the  
Inflatable PFD is fully inflated.  
To orally inflate the Inflatable PFD in an emergency situation:  
i.  
Locate the oral inflation tube by opening the zipper flap on the wearer’s left front  
panel of the inflatable PFD.  
ii. Remove the dust cap from the oral tube and blow into the tube. If the PFD does  
not break out of the zippers entirely, separate the cover zipper by hand. Continue  
blowing into the oral tube until the PFD is fully inflated.  
WARNING: Avoid double inflation (cO cylinder inflation after full oral  
2
inflation) as it could damage the PfD.  
Special considerations for Inflatable Devices  
The Inflatable PFD might not be armed when needed, either knowingly or unknowingly.  
Inadvertent inflation causes several risks that you must address to avoid drowning. Much less  
common but also important are:  
1. Double inflation (CO cylinder inflation after full oral inflation) could damage the  
2
Inflatable PFD.  
2. Inflation when stowed in a tight space could damage the Inflatable PFD.  
3. If you need to jump from any height, always fold your arms over your chest to keep the  
PFD in place when entering the water.  
4. The Inflatable PFD could inflate when you are in an awkward place or position. If this  
Inflatable PFD should inflate inadvertently, a re-arm kit (MA7214) is required to re-arm  
the device.  
IMPORTANT: The Inflatable PfD should be re-armed according to the  
instructions (Re-arming your PfD, page 8).  
7
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Usage below freezing  
When the temperature is below freezing, the Inflatable PFD should be worn partially inflated  
because a fully discharged cylinder may not quickly or adequately inflate your Inflatable PFD.  
If this happens, use the oral inflator to adequately top-up the PFD, after CO inflation.  
2
WARNING: cO2 inflation could over-pressurize and damage your Inflatable  
PfD if already fully inflated.  
Deflating the Inflatable PfD  
1. To deflate the Inflatable PFD, reverse the oral-inflation  
tube dust cap and insert it into the valve or depress  
valve with fingertip. The dust cap will not lock in the  
deflate position so it is necessary to hold it in place  
(Figure 6).  
Cap In  
Deflate  
Position  
2. Gently squeeze the Inflatable PFD until all air or gas  
has been expelled. To avoid damage, do not wring or  
twist the Inflatable PFD. Put the inflation tube dust  
cap back in its stowed position on the oral inflation  
tube (Figure 7).  
Figure 6  
IMPORTANT: Ensure all air has been removed  
from the PfD.  
Oral Inflator  
3. Examine the single point status indicator (Figure 2).  
If the indicator is red, the mechanism has been fired  
Dust cap  
in stowed  
position  
Dust cap  
position for  
deflation  
and the inflator requires service (see Re-arming your  
PFD, page 8).  
IMPORTANT: The single point status indicator  
must be green before proceeding.  
Figure 7  
4. Your device is ready to be repacked (see Repacking  
Your PFD, page 11).  
Re-arming your PfD  
NOTE: A valid re-arm kit (MA7214) is required for this procedure.  
Warning  
This gas cylinder is under pressure, therefore misuse can be dangerous.  
Do not incinerate, expose to sunlight or store above 120°f (50°c).  
Do not throw into open fire or dump at sea.  
keep away from children.  
Dispose of gas cylinders only when empty.  
Discharge and dispose of corroded or rusty cylinders.  
8
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Place the Inflatable PFD (Personal Flotation Device)  
on a smooth, flat surface and wipe off any water. If  
needed, unpack the PFD starting at the zipper flap.  
Access the inflator by reaching between the cover and  
cell and pull it toward you, turning the cell and cover  
inside-out to fully expose the inflator for re-arming.  
Hold the CO cylinder through the fabric, using one  
2
hand (Figure 8).  
2. Insert the metal key between the black locking ring  
and labeled yellow cap. Turn the key counter-clockwise  
(Figure 9).  
Figure 8  
Locking Ring  
Key  
Figure 9  
3. Turn the black locking ring counter-clockwise and lift off the cap (yellow inflator  
operating head Figure 10). Dispose of the used cap.  
Figure 10  
Cap  
4. Squeeze the sealing ring to elongate and remove the inflator body through the sealing  
ring (Figure 11).  
5. Dispose of the used inflator body (Figure 12).  
Red Indicator  
Red Indicator  
Inflator Body  
Trash  
Sealing Ring  
Figure 11  
Figure 12  
9
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Check that the new inflator body indicator is green. Insert the new inflator body with  
CO cylinder pointing upward inside the Inflatable PFD (Figure13). Let the sealing ring  
2
rest on the adapter around the four lugs.  
7. Now check the new manual/automatic cap as follows (Figure 14):  
i.  
Is the single point status indicator showing green?  
ii. Is the expiry day OK?  
Green Indicator  
Water  
Inlet  
Valve  
CAUTION:  
Do not turn  
the center  
shaft  
Single  
Point  
Indicator  
Figure 13  
Figure 14  
If YES is the answer to both questions, then proceed as follows. If the answer is NO to either  
question, get a new cap.  
8. Hold the CO cylinder through the fabric of the Inflatable PFD (Figure 15). Position the  
2
replacement cap with the water inlet valve pointing to the right and press firmly onto  
the inflator body and sealing ring (Figure 16).  
Figure 15  
Figure 16  
9. While pressing FIRMLY onto the inflator body, turn the BLACK locking ring clockwise  
into the locked position (Figure 17). Pull on the cap to make sure it has locked onto the  
inflator body.  
10. Check: To see that the single point status indicator on the cap is green; the pull-to-inflate  
lanyard is present and that the locking ring is locked.  
10  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Turn cell and cover right-side out, returning to normal state. Position the protective  
inflator cap cover over the inflator body so that the single point status indicator is visible  
through the inflator cap cover window (Figure 18).  
Lanyard  
Black  
Locking  
Ring  
Figure 18  
Figure 17  
12. If your Inflatable PFD has been used and/or the inflator replaced, always inflate through  
the oral tube and check that it stays inflated at least overnight. Empty the Inflatable PFD  
again by reversing the oral-inflation tube dust cap and inserting it into the valve or by  
depressing the valve with fingertip. Gently squeeze the inflatable PFD until all air or gas  
has been expelled. Let the Inflatable PFD dry before packing.  
IMPORTANT: Ensure all air is removed before repacking.  
13. Refold the Inflatable PFD in accordance with the Repacking section (page 11).  
Repacking your PfD  
If your Inflatable PFD has been used and/or the hydrostatic inflator replaced, always inflate  
through the oral tube and check that it stays inflated at least overnight. With the dust cap  
in the top of the oral tube, gently squeeze the Inflatable PFD until all air or gas has been  
expelled (Figure 6). Do not wring or twist the Inflatable PFD. Put the oral tube dust cap back  
in its stowed position on the oral tube (Figure 7). Let the life jacket dry before packing.  
IMPORTANT: Ensure all air is removed before repacking. before following  
the repacking sequence, be sure to properly re-arm your Inflatable PfD,  
page 8.  
1. Lay out the Inflatable PFD flat on a clean surface (Figure 19).  
2. Fold side (A) inward along the full length of the dotted line (Figure 20). Fold cover (B)  
over; covering side (A) (Figure 21).  
3. Repeat step 2 with side (C) (Figure 22), cover (D)  
(Figure 23).  
4. Ensure the inflator body is still located within its  
protective cap cover and that the single point status  
indicator is visible through the inflator cap cover’s  
A
window (Figure 18).  
B
Figure 19  
11  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Fold over the top side (E) (Figure 24) and cover (F)  
(Figure 25).  
6. Mustang Survival uses advanced 2-step zippers.  
ZIP 1 -Reset the long zipper by pulling the slider  
(G) around the top to the Velcro™ tab (H). ZIP 2  
-Close by pulling the slider (G) in the opposite  
direction to the end of the zipper (Figure 27). Ensure  
that the Inflatable cell does not get caught by the  
zipper when closing.  
A
B
Figure 20  
7. Fasten the Velcro™ tab (H) (Figure 28) to keep zipper closed.  
E
F
B
D
C
D
D
C
Figure 22  
Figure 21  
Figure 23  
Figure 24  
F
H
H
H
G
G
Figure 25  
Figure 26  
Figure 27  
Figure 28  
8. ZIP 1 – Reset the short 2-step zipper by pulling the slider (I) to the Velcro™ tab (H). ZIP  
2 – Close by pulling slider (I) in the opposite direction to the end of the zipper (Figure  
30). Ensure that the inflatable cell does not get caught by the zipper when closing.  
9. Use a finger to push the zipper ends into the openings at the bottom of the packed  
Inflatable PFD (Figure 31).  
10. Ensure the pull-tab (J) is on the outside of the folded Inflatable PFD. Figure 32 depicts a  
correctly folded Inflatable PFD.  
H
H
I
J
I
Figure 31  
Figure 32  
Figure 29  
Figure 30  
12  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Is your PfD in Good and Serviceable condition?  
Check your Inflatable PFD between uses to be sure that it is properly armed; that it is free of  
rips, tears or holes; that all seams are securely sewn; and that the fabric, straps and hardware  
are still strong (See Visual Inspection Instructions and Readiness Checklist, page 4). Inspect  
the Inflatable PFD in accordance with the Care and Maintenance instructions.  
Servicing Instructions for commercial Operators  
Federal Regulations require Coast Guard-approved personal  
flotation devices (PFDs) that are legibly marked with the Coast  
Guard approval number, are in good and serviceable condition, and  
are the correct size for each person on board.  
It is the responsibility of the operator to be sure this PFD is in serviceable condition. To  
be considered serviceable, this PFD shall not exhibit deterioration that could diminish its  
performance, such as broken or deformed hardware, detached webbing, rotted structural  
components, air leaks or nonfunctional oral inflation tube. This PFD must also be properly armed  
with a cylinder installed in the inflator, a single point status indicator showing green, and an  
accessible manual inflation lanyard. See page 3 for Instructions for Use.  
Failure to follow these instructions rigorously could result in a non-functioning PFD causing  
injury or death.  
care and Maintenance Instructions  
These instructions apply to recreational users, commercial vessel operators, and designated  
maintenance personnel. Check the following at the intervals listed below. Descriptions for  
each test are given below the table:  
INSPECTION AND MAINTENANCE SCHEDULE  
Before Each After Each CO2 Every 3  
Annually*  
Every 5  
Use (see  
item 1)  
Inflation (see Months  
(see item 4) Years (see  
item 5)  
item 2)  
(see item  
3)  
X
Visual Inspection and Readiness  
Checklist  
X
X
X
Thorough Inspection  
X
X
Inspect date of Auto-Inflation  
Mechanism  
X
X
Recommended Test Auto-Inflation  
Rearm – Replace CO2 cylinder and  
inflator  
X
X
X
X
X
X
X
X
X
X
Test Oral-Inflation  
Leak Check – 16 hours  
Clean  
Record and date Service Record label  
on PFD  
*Perform more often if exposed to potential damage or used in extreme conditions.  
13  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Before each use:  
i. Refer to the Visual Inspection and Readiness Checklist (page 4).  
2. After each CO inflation:  
2
i.  
Re-arm the Inflatable PFD. See Re-arming Your PFD, page 8. If a rearm kit is not  
available, the inflatable PFD can only be activated by oral inflation with a used  
cylinder and inflator cap installed.  
ii. If a rearm kit is available, ensure the current date is not past the date on the  
inflator. If it is, replace the inflator (see Re-arming Your PFD, page 8).  
3. Every three (3) months:  
i.  
Perform a thorough inspection:  
Examine the single point status indicator through the window panel. Ensure the  
indicator is green. If the indicator is red, the mechanism requires service (see  
Re-arming Your PFD, page 8).  
Ensure the current date is not past the date on the inflator. If the current date is  
past the date on the inflator, replace the inflator (see Re-arming Your PFD, page 8).  
The inflator’s water inlet channel is clear of obstruction.  
Visually check for rips, tears, excessive abrasion, fading, or holes. Check the seams  
for secure attachment. Ensure the hardware is not deformed. If the device shows  
damage, it may need servicing or replacement.  
Tug on seams, straps, and attachments to ensure they are still strong.  
ii. Oral Inflation Valve Test: To check the oral inflation valve, first ensure that the  
cylinder body and inflator cap are properly installed, and remove the dust cap and  
fully inflate the Inflatable PFD using the oral inflator. Test the valve by pushing  
it down using the tab provided on the cap. The valve should depress easily, and  
when released it should automatically return to the closed position and reseal.  
Fully inflate the PFD and hold the valve under water. If bubbles appear, deflate and  
re-inflate to test again. Should the leak persist, take your Inflatable PFD to your  
Mustang dealer for evaluation and/or servicing.  
iii. Leak Test: The Inflatable PFD should be tested for general leakage by orally inflating  
your Inflatable PFD until firm and let stand for 16 hours. A leaking Inflatable PFD  
will not hold its firmness and should be replaced, or take it to your Mustang  
dealer for evaluation and/or servicing. Repack the Inflatable PFD as outlined in the  
Repacking section (page 11).  
cAUTION: To avoid inflation, don't submerge the hydrostatic inflator.  
NOTE: conduct these tests more often if exposed to potential damage or  
used in extreme conditions.  
14  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Annually:  
Perform the following annually, or whenever the integrity of the Inflatable PFD is in doubt:  
i.  
Perform a thorough inspection. Refer to the Thorough Inspection instructions in  
Every Three (3) Months Care and Maintenance Instructions section.  
ii. Perform the Oral Inflation Valve Test: See the Oral Inflation Valve Test in the Every  
Three (3) Months Care and Maintenance Instructions section.  
iii. Perform the Leak Test. See the Leak Test in the Every Three (3) Months Care and  
Maintenance Instructions section.  
iv. Clean the inflatable PFD. Check for dirt and corrosion and replace all corroded  
parts. See Cleaning and Stowage of Your Inflatable PFD, page 16.  
v. Record as an "Annual" inspection in permanent ink in the Service Record label on  
the PFD. Repack the Inflatable PFD as outlined in the Repacking section (page 11).  
5. Every five (5) years:  
i.  
Perform a thorough inspection. Refer to the Thorough Inspection instructions in  
Every Three (3) Months Care and Maintenance Instructions section.  
ii. Test the Auto-Inflation Mechanism (see Inflating your Inflatable PFD, page 6) by  
submerging the device in at least four (4) inches of water depth. The device should  
inflate within 5 seconds.  
iii. Perform the Oral Inflation Valve Test: See the Oral Inflation Valve Test in the Every  
Three (3) Months Care and Maintenance Instructions section.  
iv. Perform the Leak Test. See the Leak Test in the Every Three (3) Months Care and  
Maintenance Instructions section.  
v. Clean the inflatable PFD. Check for dirt and corrosion and replace all corroded  
parts. See Cleaning and Stowage of Your Inflatable PFD, page 11.  
vi. Record as an Annual” inspection in permanent ink in the Service Record label on  
the PFD. Write an asterisk (*) next to the date to mark each five (5) year inspection.  
Re-arm and repack the Inflatable PFD as outlined in the Re-arming (page 8) and Repacking  
sections (page 11).  
WARNING: If you are not confident in the self-inspection and servicing  
of your Inflatable PfD in accordance with these instructions, take your  
Inflatable PfD to a Mustang dealer for professional servicing or contact  
Mustang Survival (see contact information on back of manual).  
15  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cleaning and Stowage of your Inflatable PfD  
To avoid inflation, do not submerge the Inflatable PFD or directly spray the inflator.  
Hand wash or sponge down the Inflatable PFD in warm, soapy water.  
Rinse the PFD and inflator with clean water, using a clean rinse cloth. Do not get inflator  
wet.  
Hang the Inflatable PFD to dry on a plastic coat hanger.  
Do not dry clean.  
Do not use chlorine bleach.  
Do not iron or dry with direct heat.  
Always store your Inflatable PFD in a warm, dry place out of direct sunlight.  
Determine if your PfD Needs Servicing  
Your PFD is required to be serviceable to be considered approved. To be considered  
serviceable, your PFD must not exhibit:  
Excessive abrasion  
Fading  
Tearing of any of the fabrics or straps  
Excessively worn components  
Contaminated components  
Punctures  
Rotted or cut straps  
Separated seams and webbing attachments – tug on the seams and ensure the  
components do not separate  
Broken or deformed hardware  
A nonfunctioning oral tube – perform the Oral Inflation Valve Test in the “Care and  
Maintenance Instructions” section under “Every Three (3) Months”, and check for  
punctures in the tube itself  
A leaking cell – perform the Leak Test as specified in the “Care and Maintenance  
Instructions” section under “Every Three (3) Months”  
If your PFD exhibits any of the above, contact your Mustang dealer for professional servicing  
or Mustang Survival (see contact information on the back of this manual).  
16  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cOMMERcIAL TRAINING cONTENT AND PROcEDURE  
This training section is provided, for the use of operational crews, to relay important  
information on the safe use and care of an inflatable work vest. A user of this device must  
be over 16 years of age, with a chest range of 30-52 inches (76-132 cm) weighing over 80  
pounds (36 kg).  
This section will detail what a user needs to know to use this inflatable work vest (and  
maintain it if designated to do so). The following information should be read by each user to  
ensure understanding of how this inflatable PFD works. (Operators may wish to designate  
certain individuals to maintain the PFDs.)  
Use  
How to inspect the device prior to use  
Inflation methods  
How to don the device  
How to remove the device  
Deflation  
Stowage  
User warnings and cautions  
Maintenance  
Re-arming  
Repacking  
Maintenance and Care  
Depending on the application, it is each user’s and each operator’s responsibility to ensure  
the inflatable work vest is fit for use and is serviceable. This vest is designed to be more  
comfortable and less restrictive to wear than a foam vest, but it will not float you  
unless inflated.  
The MD3188 features Hydrostatic Inflator Technology (HIT)™, which reduces instances of  
inadvertent inflation due to moisture or spray. The inflator must be submerged in at least four  
(4) inches of water before it automatically inflates. See “How to Inspect the Device Prior to  
Use” to ensure it will inflate as anticipated in an emergency situation.  
how to inspect the Device Prior to Use  
Read the Visual Inspection Instructions and Readiness Checklist on page 4.  
17  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Inflation Methods  
Read Inflating your Inflatable PFD on page 6. This section details the three recommended  
methods to inflate the device to provide buoyancy to the user. Additionally, read the section  
entitled How and Why to Test your PFD, page 20.  
how to Don the Device  
Read Donning Instructions on page 5 to learn how to don the device without hanging loose  
ends, which are a snag hazard.  
how to Remove the Device  
Read Removal Instructions on page 6. to learn how to remove the Inflatable Work Vest  
quickly.  
Deflation  
Read Deflating the Inflatable PFD on page 8. to learn how to remove the gas or air from the  
PFD once it has been inflated.  
Stowage  
Read Cleaning and Stowage of Your Inflatable PFD, page 16.  
User Warnings and cautions  
Always wear your PFD when underway unless you are inside a cabin. This is a  
requirement for commercial approval and is strongly advised for all users.  
This inflatable PFD must be worn and be serviceable to satisfy work vest requirements.  
Weak or non-swimmers should not use this device. In the case when oral inflation is the  
only means to obtain flotation, a user must be able to keep their head above water long  
enough to orally inflate the device.  
Do not use below freezing unless partially inflated. When the temperature is below  
freezing, a fully discharged cylinder may not quickly or adequately inflate your Inflatable  
PFD. Under these conditions use the oral inflator to adequately top-up the PFD, after CO  
inflation.  
2
Do not fasten device to boat unless the attachment is capable of being pulled free, such  
as a kill switch.  
Do not wear this device under clothing, as inflation under clothing will restrict breathing  
or may otherwise injure you.  
Always have re-arm kits (MA7214) available to service your inflatable work vest.  
Check the date of the Inflator cap to ensure it has not expired.  
If you need to jump from any height, always fold your arms over your chest to keep the  
PFD in place when entering the water.  
18  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Avoid unnecessary exposure to sunlight. Sunlight will degrade the performance of the  
textile components.  
Use extreme caution around sharp objects.  
Avoid all unnecessary activities that will be abrasive to the device.  
When inflated by CO gas, it will permeate through the fabric over long periods of time.  
2
Topping up the inflatable cell by oral tube may be necessary.  
Inflatable PFDs are not designed for use in white water, or other high-speed activities.  
A PFD will not protect you from impact.  
Dropping this PFD in water may result in an inadvertent inflation.  
Inadvertent inflation in a tight space may damage the PFD.  
Re-arming  
Read Re-arming Your PFD on page 8.  
Repacking  
Read Repacking Your PFD on page 11.  
care and Maintenance  
A recommended maintenance schedule is provided in the Care and Maintenance Instructions  
section on page 13.  
Service Record and Inspection Log Procedure  
Test this device at the beginning of each season and service annually. Refer to Care and  
Maintenance schedule page 13. Record annual inspections in the Service Record label on  
the PFD. Every five (5) years, write an asterisk (*) next to the date to denote five (5)-year  
maintenance (example log is shown below). Space is provided on the label to record the  
User’s Name, Date Maintained, and Name of person who inspected and serviced the PFD. This  
record must be maintained and made available at all times for inspection to meet carriage  
requirements.  
19  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example Log  
Date  
Service / Initials  
Ann. inspec. / CS  
Ann. inspec. / CS  
Ann. inspec. / DB  
Ann. inspec. / DB  
Ann. inspec. / SG  
Ann. inspec. / SG  
Ann. Inspec / SG  
Jan 2005  
Jan 2006  
Jan 2007  
Jan 2008  
Jan 2009*  
Jan 2010  
Jan 2011  
Why ARE PfDS REqUIRED SAfETy EqUIPMENT?  
Drowning is the leading cause of fatalities involving recreational and commercial vessels. A  
PFD provides flotation to help keep your head above water, help you to stay face up in the  
water, and increase your chances for survival and rescue. Most adults only need an extra 7 to  
12 lbs (3.2 to 5.5 kg pounds) of flotation to keep their heads above water. The proper size PFD  
will properly support the weight of the wearer.  
Since this Inflatable PFD does not have inherent buoyancy, it provides flotation only when  
inflated. Familiarize yourself with the use of this Inflatable PFD so you know what to do in an  
emergency.  
how and Why to Test your PfD  
Inflate your Inflatable PFD and try it out in the water to:  
Make sure it floats you:  
Comfortably (when worn properly)  
Adequately for expected wave conditions (body shapes / densities affect performance)  
Make sure it works:  
A flow of bubbles should not appear (see Care and Maintenance Instructions for Leak  
Tests, page 14). It should inflate quick and easily.  
Learn how it works by:  
Activating the CO inflation system  
2
Re-arming the CO inflation system  
2
Using the Oral inflator tube  
20  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
how Do you Test your PfD Using the Automatic Inflator?  
The US Coast Guard recommends that you purchase at least two spare re-arming kits  
(MA7214).  
1. To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming  
kit (MA7214) approved for your Inflatable PFD.  
2. Put on the Inflatable PFD.  
3. Get into shallow water, just deep enough that you can stand with your head above the  
surface. Once the inflator is underwater, 4 inches or so, the Inflatable PFD should fully  
inflate automatically within 5 seconds.  
4. See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a  
relaxed floating position, verify that your mouth is well above the water’s surface. Note  
the effect of where you hold your legs on how you float.  
5. Get out of the water and remove the Inflatable PFD.  
6. Deflate the Inflatable PFD by depressing the oral inflator valve (see Deflating the  
Inflatable PFD page 8). Remove the used inflator.  
7. Let the Inflatable PFD dry thoroughly. Re-arm (page 8) and Repack the PFD (page 11).  
how Do you Test your PfD Using the Manual Inflator?  
The U.S. Coast Guard recommends that you purchase at least two spare re-arming kits  
(MA7214).  
1. To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming  
kit approved for your Inflatable PFD: MA7214.  
2. Put on the Inflatable PFD.  
3. Actuate the inflation system by jerking firmly downward on the pull-tab. The Inflatable  
PFD should fully inflate within 5 seconds.  
4. Get into shallow water, just deep enough that you can stand with your head above the  
surface.  
5. See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a  
relaxed floating position, verify that your mouth is well above the water’s surface. Note  
the effect of where you hold your legs and how you float.  
6. Get out of the water and remove the Inflatable PFD. Completely deflate the Inflatable  
PFD using the oral inflator (see Deflating the Inflatable PFD page 8).  
7. Let the Inflatable PFD dry thoroughly. Re-arm (page 8) and Repack the PFD (page 11).  
21  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
how Do you Test your PfD Using the Oral Inflator?  
WARNING: Use only a previously used hydrostatic inflator, with the single  
point status indicator showing red, to perform this test. DO NOT test with  
a fully armed hydrostatic inflator as double inflation will occur, possibly  
resulting in damage to the PfD.  
1. No spare parts or re-arming kits are needed to test your Inflatable PFD.  
2. Review the oral inflation instructions (page 7) regarding break-out zippers.  
3. Put on the Inflatable PFD.  
4. Get into shallow water, just deep enough that you can stand with your head above the  
surface.  
5. If you are a weak swimmer or non-swimmer, inflate the Inflatable PFD partially so  
that you are supported well enough to be able to complete inflation without touching  
bottom, either orally or manually. Note this level of inflation because it is the minimum  
needed for you to safely use this Inflatable PFD.  
6. Fully inflate the Inflatable PFD using the oral inflator.  
7. See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a  
relaxed floating position, verify that your mouth is well above the water’s surface. Note  
the effect of where you hold your legs and how you float.  
8. Get out of the water and remove the Inflatable PFD. Completely deflate the Inflatable  
PFD using the oral inflator (see Deflating the Inflatable PFD page 8).  
9. Let the Inflatable PFD dry thoroughly. Re-arm (page 8) and Repack the PFD (page 11).  
Wear your PfD  
In approximately 80 percent of all boating fatalities, the victims were not wearing a PFD. Most  
fatal accidents happen on calm sunny days. This Inflatable PFD is much more comfortable to  
wear than other PFD types. Get into the habit of wearing this Inflatable PFD. Non-swimmers  
and children especially should wear a hybrid or non-Inflatable PFD at all times when on or  
near the water.  
hyPOThERMIA  
Prolonged exposure to cold water causes a condition known as hypothermia - a substantial  
loss of body heat, which leads to exhaustion and unconsciousness. Most drowning victims  
first suffer from hypothermia. The following chart shows the effects of hypothermia.  
22  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
how hypothermia Affects Most Adults  
Water Temperature  
ºc (ºf)  
Time to Exhaustion or  
Estimated Survival Time  
Unconsciousness  
0.3 (32.5)  
0.3-4 (32.5-40)  
4-10 (40-50)  
10-16 (50-60)  
16-21 (60-70)  
21-27 (70-80)  
>27 (80)  
<15 min  
15-30 min  
30-60 min  
1-2 hrs  
<15-45 min  
30-90 min  
1-3 hrs  
1-6 hrs  
2-7 hrs  
2-40 hrs  
2-12 hrs  
indefinite  
3 hrs to indefinite  
indefinite  
PFDs can increase survival time because they allow you to float without using energy treading  
water and because of their insulating properties. Naturally, the warmer the water, the less  
insulation you will require. When operating in cold waters [below 60°F (15.6°C)] you should  
consider using a coat or jacket style PFD or a Type V Thermal Protective PFD as they cover  
more of the body than the vest or belt style PFDs.  
Some points to remember about hypothermia protection:  
1. Always wear your Inflatable PFD. Even if you become incapacitated due to hypothermia,  
the Inflatable PFD will keep you afloat and greatly improve your chances of rescue.  
2. Do not attempt to swim unless it is to reach a nearby craft, fellow survivor, or a floating  
object on which you can lean or climb. Swimming increases the rate of body heat loss.  
In cold water, drown-proofing methods that require putting your head in the water are  
not recommended. Keep your head out of the water. This will greatly lessen heat loss and  
increase your survival time.  
3. Use the standard H.E.L.P. position when wearing an Inflatable PFD, drawing the legs up  
to a seated position, because doing so will help you conserve body heat (Figure 33).  
4. Keep a positive attitude about your survival and rescue.  
This will improve your chances of extending your  
survival time until rescued. Your will-to-live does make a  
H.E.L.P. Position  
difference!  
5. If there is more than one person in the water, huddling  
is recommended while waiting to be rescued. This action  
tends to reduce the rate of heat loss and thus increase the  
survival time.  
Figure 33  
23  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Each of These Devices is Intended to help you Save your  
Life  
For your Inflatable PFD to function properly, follow these suggestions to verify that it fits,  
floats, and remains in good condition.  
1. Check the single point status indicator before each use.  
2. Get in the habit of re-arming the inflation mechanism right after each inflation.  
3. Try your wearable Inflatable PFD on and adjust it until it fits comfortably in and out of  
the water.  
4. Mark your Inflatable PFD with your name if you are the only wearer.  
5. Do not alter your Inflatable PFD. If it doesn’t fit properly, get one that does. An altered  
device is no longer Coast Guard approved.  
6. Your Inflatable PFD is not intended for use as a fender or kneeling pad.  
7. If your Inflatable PFD is wet, allow it to dry thoroughly before storing it. Store it in a  
well-ventilated area.  
8. Do not dry your Inflatable PFD in front of a radiator or other source of direct heat.  
Inflatable PfD Safety Accessories  
MA7214 Re-arm Kit contains 33-gram replacement CO cylinder with inflator body, a new  
2
manual/automatic inflator cap with black locking ring and manual pull-tab, metal key, and  
Re-arming instructions.  
ADDITIONAL INfORMATION  
If you need more information about PFDs and safe boating, contact your state boating  
authority, U.S. Coast Guard Auxiliary, U.S. Power Squadron, Red Cross, or your nearest unit of  
the U.S. Coast Guard; or call the free boating course number 1-800-336-BOAT (in Virginia, call  
1-800-245-BOAT).  
Do Not Attach PfDs to your boat  
Each PFD has straps, hooks, buckles, or other means for securing the device in place on the  
wearer. Some PFDs also incorporate decorative d-rings or tabs. Such items are not to be used  
to attach the device to the boat. Attaching the device to the boat will not permit it to perform  
as intended.  
Airline Operator Policy on carriage of Inflatable PfDs  
and cO2 cartridges  
Please be aware that the following regulations apply to the air transport of this product.  
According to U.S. Research and Special Programs Administration Regulations Title 49 CFR  
75.10(a)(25): With the approval of the aircraft operator, one small carbon dioxide cylinder  
fitted into a self-inflating jacket, plus one spare cartridge, may be carried by a passenger or  
crew in checked or carry-on baggage.  
24  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GLOSSARy  
Term  
Definition  
CO  
carbon dioxide  
2
Hot Work  
Permeation  
PFD  
burning, welding, riveting, grinding, etc.  
passage or diffusion of a gas through a barrier  
Personal Flotation Device  
USCG  
United States Coast Guard  
25  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
MD3188 Inflatable PFD Manufacturer's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DO NOT REMOVE  
PRIOR TO SALE  
For 40 years Mustang Survival has been committed  
to providing life support solutions. Through constant  
innovation and the application of new technologies,  
Mustang is the leading supplier of quality flotation and  
hypothermia protection products to the most demanding  
users – from fishermen, sailors and power boaters to the  
Coast Guard, jet fighter pilots and even NASA astronauts.  
TOLL FREE:  
EMAIL:  
1.800.526.0532  
Mustang Survival and seahorse design is a registered trademark of  
Mustang Survival Corp.  
Our commitment to quality has earned our Burnaby facilities ISO  
9001 registration, the highest of all international standards. This is our  
guarantee you are receiving the ultimate in design and manufacturing.  
HT-2132 (Rev. 10Aug2011)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTX Audio Speaker JackHammer User Manual
Multi Tech Systems Fax Machine E1 User Manual
National Instruments Network Card NI 1410 User Manual
NEC Drill 0612 20 User Manual
NETGEAR Network Card WG111T User Manual
Netopia Network Router 45413 User Manual
Olympus Camera Lens EX 25 User Manual
Olympus Microcassette Recorder VN 7600PC User Manual
Omnimount TV Mount OL200FT User Manual
Panasonic Medical Alarms ESB91 User Manual