Home Smart Center
MODEL: ML-001 / ML-100
TM
CUSTOMER SERVICE
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Tel : (905) 456-8883
PATENTED
©2011 SKYLINK GROUP
Fax : (905) 456-7819
Email : [email protected]
P/N. 101Z379-001
FEB, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
When using your telephone equipment, basic safety precautions should
always be followed to reduce the risk of fire, electric shock and injury to
persons, including the following:
1. Do not use this product near water, for example, near a bath tub, wash
bowl, kitchen sink or laundry tub, in a wet basement or near a swimming
pool.
2. Avoid using a telephone (other than a cordless type) during an
electrical storm. There may be a remote risk of electric shock from
lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord and batteries indicated in this manual. Do not
dispose of batteries in a fire. They may explode. Check with local codes
for possible special disposal instructions.
5. Plug the adaptor to the socket-outlet that near the equipment and
shall be easily accessible.
SAVE THESE INSTRUCTIONS
Attention
This product is not an alarm system providing facilities to summon
assistance, for use by persons who can be considered to be living
at risk. This product is not intended to for use in health care signaling
equipment or directly connect to central-station (Police, Medical, Fire).
–1–
Download from Www.Somanuals.com. All Manuals Search And Download.
IC Statement
Declaration of Conformity
‘’This product meets the applicable Industry Canada technical
specifications.”
Application of Council Directive(s) :
Radio Equipment and Telecommunication Terminal Equipment
Directive (1999/5/EC) - R&TTE
Before installing this equipment, users should ensure that it is permissible
to be connected to the facilities of the local telecommunications com-
pany. The equipment must also be installed using an acceptable method
of connection. In some cases, the company’s inside wiring associated
with a single line individual service may be extended by means of a
certified connector assembly (telephone extension cord). The customer
should be aware that compliance with the above conditions may not
prevent degradation of service in some situations.
Standard(s) to which Conformity is Declared:
EMC:
EN 55022:1998+A1: 2000, EN 610000-3-2: 2000,
EN 61000-3.3: 1995 +A1:2001, EN 55024: 1998+A1: 2001,
EN 50130-4: 1995/A1: 1998, EN 300220-3: 2000,
EN 301489-3: 2002
Safety:
Repairs to certified equipment should be made by an authorized Canadian
maintenance facility designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may give
the telecommunications company cause to request the user to disconnect
the equipment.
EN 60950-1: 2001, EN 50371: 2002
Telephony:
TBR 21: 1998
Manufacturer’s Name:
Capital Prospect Limited
..........................................................................................
Users should ensure for their own protection that the electrical ground
connections of the power utility, telephone lines and internal metallic water
pipe system, if present, are connected together. This precaution may be
particularly important in rural areas.
Manufacturer’s Address:
Room 3, 13/F, Block B, Veristrong Industrial Centre,
..........................................................................................
36 Au Pui Wan Street, Fo Tan, N.T., Hong Kong
..........................................................................................
Type of Equipment:
Model No.:
Home Smart Center
..........................................................................................
Caution: Users should not attempt to make such connections themselves,
but should contact the appropriate electric inspection authority, or electri-
cian, as appropriate.
AM-002
..........................................................................................
Serial No.:
Not Labelled
..........................................................................................
‘’The Ringer Equivalence Number is an indication of the maximum
number of terminals allowed to be connected to a telephone inter-
face. The termination on an interface may consist of any combination
of devices subject only to the requirement that the sum of the Ringer
Equivalence Numbers of all the devices does not exceed five.’’
Year of Manufacture:
2005
..........................................................................................
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive (s) and Standard(s).
Place: Hong Kong
................................................
Joe Ng
Project Manager
Date:
21st July 2005
................................................
–55–
–2–
Download from Www.Somanuals.com. All Manuals Search And Download.
g) Should you experience trouble with this equipment, please contact
Skylink Customer Support at 1-800-304-1187 for repair or warranty
information. If the equipment is causing harm to the telephone network,
the telephone company may request that you disconnect the equipment
until the problem is resolved.
CONTENT
Introduction..........................................................................................................................4
Overview........................................................................................................................4
Installation...........................................................................................................................7
Installing the Console.................................................................................................7
Programming Passwords..........................................................................................9
Phone Number Programming..................................................................................10
Contact ID Phone number.......................................................................................12
Phone Number Programming (Calling to Central Monitoring Station)................12
Account Number Programming..................................................................................13
Deactivating the Digital Dialer.................................................................................14
Installing Door/Window Sensors................................................................................15
Installing Motion Sensor..........................................................................................16
Operation..........................................................................................................................18
Alert mode...................................................................................................................18
Mute....................................................................................................................................19
System Status..............................................................................................................20
Arming The System.....................................................................................................20
Disarming the system...............................................................................................21
Disarming a triggered control panel.....................................................................22
Disarming under Duress..........................................................................................22
Panic...................................................................................................................................23
System Failure............................................................................................................23
Phone Line Failure............................................................................................23
Sensor Failure.....................................................................................................24
Low Battery...........................................................................................................24
Coummunication.............................................................................................................26
Receiving an emergency call..................................................................................26
Remote Operation by Telephone...........................................................................27
To access the control panel away from home......................................................27
Advanced Programming.................................................................................................29
Zone Dependent Setting – Beep /Alarm..............................................................29
Zone Dependent Setting –Auto Mute....................................................................32
Zone Dependent Setting –Alert Zone (Bypass zone).........................................33
Learn Keychain / Keypad Remotes........................................................................35
Erase Keychain / Keypad Remotes........................................................................36
Learn Sensors..............................................................................................................37
Sensor Location Selection Guide.............................................................................37
Erase Sensors...........................................................................................................39
HomeAutomation.............................................................................................................40
Learn Control Modules............................................................................................40
Erase Control Modules............................................................................................43
Event Trigger..............................................................................................................45
Trouble Shooting..............................................................................................................47
Accessories......................................................................................................................49
System Configuration.....................................................................................................53
FCC Information................................................................................................................53
h) Please follow instructions for repairing if any (e.g. battery replacement
section); otherwise do not alternate or repair any parts of device except
specified.
i) Connection to party line service is subject to state tariffs. Contact the
state public utility commission, public service commission or corporation
commission for information.
j) NOTICE: If your home has specially wired alarm equipment connected to
the telephone line, ensure the installation of this modelAM-002 does not
disable your alarm equipment. If you have questions about what will
disable alarm equipment, consult your telephone company or a quali-
fied installer.
NOTICE: According to telephone company reports, AC electrical surges,
typically resulting from lightning strikes, are very destructive to telephone
equipment connected toAC power sources. To minimize damage from
these types of surges, a surge arrestor is recommended.
CE........................................................................................................................................55
–54–
–3–
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC Information
INTRODUCTION
Consumer Information:
Overview
a) This equipment complies with Part 68 of the FCC rules and the require-
ments adopted by the ACTA. On the bottom of this equipment is a label
that contains, among other information, a product identifier in the format
US:AAAEQ##TXXXX. If requested, this number must be provided to the
telephone company.
Congratulations on your purchase of a Home Smart Center. This is a security
control panel which not only functions as a security system, but also monitors
your premises by giving you alert notification when the system is not armed. It
is also a home automation center, which allows you to remotely control house-
hold appliances and lights, even when you are away from home. It can be
controlled by dialing in from any touch tone phone, which makes it even more
convenient and powerful. Additional accessories such as different kinds of
sensors and controllers can be added to suit your specific needs.
b) An applicable certification jacks Universal Service Order Codes (USOC)
for the equipment is provided (i.e., RJ11C) in the packaging with each
piece of approved terminal equipment.
This user instructions will guide you through the whole setup procedure as well
as all the programming instructions. Please follow the instructions closely, you
should find it very easy to set up the system.
c) A plug and jack used to connect this equipment to the premises wiring
and telephone network must comply with the applicable FCC Part 68
rules and requirements adopted by theACTA.Acompliant telephone
cord and modular plug is provided with this product. It is designed to be
connected to a compatible modular jack that is also compliant. See
installation instructions for details.
Alert
Automation
When Home (System Not Armed)
Beep Beep
Alarm
d) The REN is used to determine the number of devices that may be con-
nected to a telephone line. Excessive RENs on a telephone line may
result in the devices not ringing in response to an incoming call. In most
but not all areas, the sum of RENs should not exceed five (5.0). To be
certain of the number of devices that may be connected to a line, as
determined by the total RENs, contact the local telephone company. [For
products approved after July 23, 2001, the REN for this product is part of
the product identifier that has the format US:AAAEQ##TXXXX. The digits
represented by ## are the REN without a decimal point (e.g., 03 is a
REN of 0.3). For earlier products, the REN is separately shown on the label.]
Not Home (System Armed)
Communicator
Zone 1
Sensor 1
Triggered
Alarm
In the package, you should find the following items:
•
•
•
•
One Control Panel
ML-001A
e) If this equipmentAM-002 causes harm to the telephone network, the
telephone company will notify you in advance that temporary discontinu-
ance of service may be required. But if advance notice isn’t practical, the
telephone company will notify the customer as soon as possible. Also,
you will be advised of your right to file a complaint with the FCC if you
believe it is necessary.
One Motion Sensor (For ML-100A Only)
Two Door / Window Sensors (For ML-100A Only)
PS-101
f) The telephone company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the equipment.
If this happens the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted
service.
WD-101
One Keychain Remote (For ML-100A Only)
4B-101
–4–
–53–
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM CONFIGURATION
INTRODUCTION
Master Password
____________________
•
One AC adapter
Secondary Password ____________________
Duress Password
____________________
•
•
One telephone cord
Sensor locations and settings
Batteries for all sensors (For ML-100A Only)
- 1 PC 9V Alkaline Battery (PS-101)
- 1 PC 12V Alkaline Battery Type 23A
(4B-101 -installed)
- 2 PCS 3V Lithium Battery CR-2032
(WD-101 -installed)
ZONE
SENSOR 1
SENSOR 2
BEEP / ALARM AUTO MUTE
Beep / Alarm Y / N
EVENT TRIGGER ALERT
Example
Front Door
Front Window
Disabled / On / Off
Y / N
1
2
3
4
5
•
•
Rechargeable battery of the Control Panel:
North American version
Phone number settings
PHONE MEMORY
PHONE NUMBER
321-123-4567
REDIAL COUNT
REPEAT COUNT
Example
5
5
1
2
3
4
5
European Version
Mounting hardware
Ball-head joint
(For ML-100A Only)
Keychain / Keypad Remotes settings
Mounting Plate
(For ML-100A Only)
KEYCHAIN / KEYPAD LOCATIONS
OWNER (KEYCHAIN) / LOCATION (KEYPAD)
Example
Keychain Owner - John
6
7
8
9
0
Screws
Pack
Basic installation involves the following procedures:
Control Modules settings
1. Install Control Panel ML-001A
2. Program Passwords
CONTROL MODULES
LOCATIONS / APPLIANCES
Example
Family room lighting
6
7
8
9
0
3. Program Phone Numbers
4. Install Door / Window Sensors WD-101 (For ML-100A Only)
–52–
5. Install Motion Sensor PS-101 (For M–L5-1–00A Only)
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
INTRODUCTION
7
8
11
1
Control Module SW-100
(US and Canada)
- To turn home appliances / lights on / off
]
- Max rating: 960W (Resistive)
2
Control Module SW-101U (UK), SW-101F
(French), SW-101G (German)
(3 models for 3 countries)
- To turn home appliances / lights on / off
3
4
5
6
10
9
17
18
Emergency Dialer (AD-433S)
- External dialer with user programmable voice
message
905-608-9223
- Calls up to 9 phone numbers
®
AD-433
- One personal voice recording up to 40 seconds
- Can be installed anywhere within 100 feet from
the control panel, with a phone socket
13
12
Swing door opener (DM-100)
- Remotely open / close a swing door
- Fits most interior doors
16
14
15
1. Zone LEDs
2. Numeric Keypad
3. Arm button
11. Built-in Siren and Speaker
12. Programming button
13. Buzzer Mode Selector
4. Status button
5. Mute button
6. Panic button
7. Power LED
8. Arm LED
14. Phone Jack for external phone
15. Line Jack for telephone line
16. Adapter socket
17. Battery Compartment
18. Language Selector (only available for
models support multiple languages)
9. Program LED
10. System Low Battery LED
–6–
–51–
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
INSTALLATION
Installing the Console
Audio Sensor (AS-101)
It is important determine where the control panel will be located. Please follow
the criteria below to select the ideal location for the control panel.
- When audio level exceeds preset limit, it will trigger the
alarm
- Place beside smoke detector, CO detector, so when these
-
-
-
Place it where electrical outlet and phone line can be accessed
Place it where it is easily accessible by the users
Place it away from any doors or windows which could be accessed by
non-intended users
detectors are triggered, the control panel will be triggered
-
Place is away from extreme temperature sources such as oven, stove
and away from large metal objects which could affect the wireless
performance
Remote Control (4B-101)
- Additional keychain remotes for other family members
- To arm, disarm or trigger the panic alarm with this remote
After a location has been selected, you may begin the installation and connect all
the necessary wires and power up the unit.
Keypad Control (KP-434)
- External keypad control
- To arm, disarm or trigger the the panic alarm with this
remote
1. Undo the 2 screws on the battery cover.
- Ideal mounting locations include upper floor, backdoor, or
garage
Wrist Watch Style Panic Remote (HW-101)
- Activate the panic alarm instantly with this remote
- Wear it as a watch
2. For models support multiple languages,
Language
select the desired language based on
selector
- Splashproof design, can be worn during showering
the setting below:
1. German
2. Spanish
3. French
4. English
Panic Transmitter (PT-101)
- Activate the panic alarm instantly with this remote
- Wear it as a pendant
- Splashproof design, can be worn during showering
3. Connect the power adapter to the
socket inside the battery compart-
ment. The power adapter should
be connected to an AC electrical
outlet. You should see all LEDs
turn on, LO BATT LED should be
off.
®
Audio Alarm (AA-433)
- External Siren
- Powered by AC adapter with backup battery
–50–
–7–
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
INSTALLATION
4. Insert the rechargeable battery to the battery compartment. There are 2
different types of rechargeable battery for 2 markets:
Additional sensors and transmitters as well as add on accessories are available
to work with your system.
a. North American Version: Lead Acid
Connect the 2 wires to the battery. Red wire
connects to the “+” terminal on the battery.
Black wire connects to the “-” terminal on the
battery. Markings on the battery should face up.
Door/Window Sensor (WD-101)
- Magnetic Contact Sensor
- For all doors or windows
- Batteries included
b. European Version: Ni-MH
Plug in the wire from the battery to the battery
socket inside the battery compartment.
Repeater (RP-434)
- Extend the operation range between 2 wireless devices,
such as any sensors and control panel
- Doubles the operation range automatically between
sensors and control panel
5. After inserting the rechargeable battery, the LO
BATT LED will be off if the battery is fully
charged, otherwise it will be on.
6. Connect the phone line from the wall socket to
the “LINE” socket inside the battery
compartment.
Water Sensor (FS-101)
7. [OPTIONAL] If another telephone that will be
using the same telephone jack, you may
- Alerts you when water is detected
- Ideal for water detection in basement, under the sink, even
bathroom
connect this telephone to “PHONE” outlet of the
control panel by a phone cord (not provided).
(Optional)
8. The phone line(s), cord of the power adapter
should all come out from the lower right corner
of the control panel in order to close the battery
cover properly.
Garage Door MonitorTM Sensor (GS-101)
(Available in US and Canada)
- Monitors your garage door
- Alerts you when the garage door is left open
9. The battery cover can now be closed, and tighten
the 2 screws to secure the battery cover.
PWR, ARM, PROG LEDs should be flashing,
zone LEDs should be off.
Garage Door MonitorTM Sensor (GS-102)
(Available outside US and Canada)
- Monitors your garage door
10. The control panel is intended to be mounted on a
flat wall. 2 screws are required to mount the
control panel securely on the wall. It should not be
mounted too high or too low. In most situations, just
below eye level is ideal.
- Alerts you when the garage door is left open
7-1/8"
11. Once you have selected the mounting
location, tighten 2 screws on the wall.
They should be
Indoor/Outdoor Motion Sensor (PS-101)
- Monitors area in a 110 degree ARC and up to 40 feet away
from the sensor
7-1/8" apart from each other, on the same
horizontal level. Do not tighten the screws
all the way in, leave about 1/8" from the
wall in order for the control panel to be
hanged onto the wall.
TM
–8–
–49–
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLE SHOOTING
INSTALLATION
Programming Passwords
Sensors
Master Password can be used for programming, arming, disarming the
system, and telephone access. The default Master Password is [1234].
When a sensor is triggered, the
control panel doesn’t respond at all,
what is the problem?
- Make sure the battery in the sensor is
installed properly, pay attention to the
polarity.
- Make sure the sensor is learned to the
control panel. Follow instructions on
page 37 on how to learn a sensor.
- You may try to bring the sensor closer to
the control panel, ensure it is not out of
the operation range.
Secondary Password can be used for arming, disarming the system, and
telephone access. Secondary Password cannot be used for programming.
The default Secondary Password is [0000].
Duress Password is used when you are forcibly compelled to disarm the
control panel. Entering the duress password will stop the siren from sounding
but the control panel will silently call the emergency phone numbers for help.
The default Duress Password is [3838]. You should definitely change this
password and let all the users know this password.
My motion sensor sometimes gets
triggered by itself, how can I prevent
that?
Ensure the motion sensor is not facing
direct sunlight, nor any A/C or furnace
vents. You may also reduce the sensitivity
to low. If your motion sensor is located
outdoors, you may want to relocate it.
After mounting the door sensor, it
doesn’t work anymore.
- Please ensure the magnet is aligned with
the red marking on the transmitter.
Changing Passwords
- If you are mounting the sensor on to a
metal door or window, a spacer may be
required to avoid magnetic interference
caused by the metal door / window.
- Make sure the sensor is within the operation
range of the control panel by bringing it
closer to the control panel.
It is strongly recommended to change all 3 passwords when you first set
up the system.
In order to change the password, follow the procedures below.
Step
Keys
Function
Description
Note
[PROG]
Enter master
password to
programming mode
3 beeps for valid
password. 1 long
beep for invalid
password.
My motion sensor is not very
responsive, sometimes when I walk
by it, the control panel doesn’t respond,
but sometimes it does.
The motion sensor is designed to detect the
“First Motion”. First Motion means no motion
is detected within the past 20 seconds,
and if a motion is then detected, that is the
“First Motion”. So if you continue to walk
in front of the motion sensor, it will only
pick up the first motion. Unless you wait
for 20 seconds, then walk again, the control
panel will respond. Otherwise, the control
will only respond to the first motion.
Enter
Programming
mode
1
[MPIN]
[2]
Select
password
programming
2
3
[1] - Master password
[2] - Secondary password
[3] - Duress password
[1] or
[2] or
[3]
Select which
password to
change
[new
4-digit
password]
Select any 4-digit pass-
word, each digit can be
from 0 to 9
Enter new
password
4
5
[new
4-digit
password]
Enter new
password to
confirm
Enter the new password 3 beeps if new pass-
again for confirmation
word is accepted. You
will hear [Password
Accepted]
–48–
–9–
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
TROUBLE SHOOTING
Phone Number Programming
Control Panel
You can program up to 6 Emergency Phone Numbers. When the system is in panic,
the control panel will call these phone numbers and announce its status.
Questions
Solutions
Why I can’t arm my system?
Make sure none of the sensors are
triggered. You can check this by the zone
LEDs, none of them should blink.
The 6 emergency phone numbers include:
- 5 voice message phone numbers
- 1 Contact ID message phone number
I cannot arm the system even when no
sensor is triggered, and the ARM LED
is off.
You need to disarm the system again by
either entering the password or disarm by
keychain remote. Although the ARM LED
is off, but the system is not completely
disarmed after an alarm was triggered.
Refer to page 22 on how to completely
disarm a control panel after an alarm has
been triggered.
Program the following for Voice Message Phone Numbers
- Phone memory (from 1 to 5), this is where the phone numbers will be stored
- Phone number, up to 29 digits.
- Redial count, this is how many times that phone number will be called, from 1
to 9 times.
- Repeat count, this is how many times the emergency message will be repeated,
from 1 to 9 times.
Step
Keys
Function
Description
Note
Why the ARM LED keeps flashing?
That means you have not programmed any
emergency phone numbers. For instructions
on how to program emergency phone
numbers, please see page 10.
Enter
Programming
mode
Enter master password to
programming mode
3 beeps for valid
password. 1 long beep
for invalid password.
1
[PROG]
[MPIN]
Select phone
number
programming
You will hear [Enter
phone memory].
2
3
[1]
How do I exit programming mode
when I’m in the middle of it?
You can press the programming button on
the side of the unit to quit programming
anytime.
During emergency, phone
memory 1 will be called first,
then phone memory 2, 3, 4, and
5. So phone memory 1 has
higher priority.
Enter phone
memory
[1] to [5]
When a sensor is triggered, the alarm
sounds instantly even it is not armed,
why is that?
You have programmed that sensor in alarm
mode, instead of beep mode. Please refer
to page 29 for instructions of how to program
it back to beep mode.
Phone number can be up to 29
digits.**
You will hear [Enter
Redial].
[Phone
Enter phone
number] number
+ [Arm]
4
5
When the alarm is triggered, why
the control panel won’t call all the
programmed phone numbers? It
always stops before calling the
last number.
The control panel will stop calling when it
is disarmed by any one of the recipients.
Disarm can also be done locally thru the
keypad on the control panel by entering a
valid password.
You will hear [Enter
Repeat].
Redial is the number of times
that phone number will be
called. Each phone number
can have a different redial
count, from 1 to 9 times.
Enter Redial
[1] to [9]
+ [Arm]
count
Why the control panel doesn’t beep
when a sensor is triggered, while
only the zone LED flashes?
You have placed the buzzer mode selector
on the side of the control panel to “II”, this
will disable the beeping. Placing it to “I” will
enable the beeping.
Repeat is the number of times
that voice emergency message
will be played, from 1 to 9 times.
It is recommended to set up
the repeat time to 5 or more.
You will hear [Phone
Accepted] indicating the
phone number and its
settings have been
Enter Repeat
count
6
[1] to [9]
+ [Arm]
The control panel is in armed mode,
why activating a sensor will not cause
an alarm, or call any emergency phone
number?
If the triggered sensor is programmed in the
Alert Zone (Bypass Zone), alarm will not
sound, and emergency call will not be made
if this sensor is triggered. The control panel
will only respond when it is disarmed, in
alert mode.
programmed successfully.
**Note:
You may enter a 3-second pause between digits by pressing [Mute] if needed.
You may also enter consecutive multiple pause periods. For example, you may
enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number
(123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be
a password to a paging system, or an access code for a phone dialing system.
–47–
–10–
Download from Www.Somanuals.com. All Manuals Search And Download.
HOME AUTOMATION
INSTALLATION
Note:
- It’s not recommended to program 911, fire station or any emergency services
phone numbers into any of the phone memories without their approvals.
- Ensure to program a valid phone number and write down the programmed
phone number on the System Setting Information provide on the back of this
user's instructions.
®
This row
Buttons to Disable Event Tigger
:
Zone LED : Off
- You may quit programming by pressing [PROG] button at any time.
- If no phone number is programmed, the ARM LED will continue to flash.
Press once will enable “Event Trigger On”,
press again will enable “Event Trigger Off”.
This row of buttons operates in toggle manner,
between event trigger on and event trigger off.
Testing Phone Numbers:
This row
:
Buttons to Enable Event Trigger
After you have programmed all the phone numbers, you should verify you have
programmed the phone numbers correctly. This can be done by triggering the
alarm silently by entering the duress password, so it dials to the programmed
phone numbers without sounding the alarm.
Zone LED : 1) On (Event Trigger On)
2) Flash (Event Trigger Off)
ENABLE EVENT TRIGGER
DISABLE EVENT TRIGGER
Button [1]
Note:
Zone 1
Zone 2
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
You must inform the recipients of the programmed phone numbers, so they know
what to expect when they receive the phone call from the control panel during an
emergency. These recipients should know the password to your control panel if
you expect them to have remote access of your control panel. For more informa-
tion regarding receiving the emergency call, please refer to page 26.
Button [2]
Button [3]
Zone 3
Zone 4
Zone 5
Button [4]
Button [5]
1. Press [Arm], you should hear beeping from the control panel.
2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number.
3. The called party should receive the call. Pick up the call and say “Hello”, an
emergency message “System Panic” will be played. If the programmed phone
doesn’t ring, ensure the phone number is programmed correctly, or reprogram
this phone number again.
4. After the emergency message has been played for several times (depending on
how many times it was programmed), the called party will hear “Enter Password”.
5. Enter either the master password or secondary password. If the correct
password is accepted, you will hear “Password Accepted”, otherwise, you will
hear “Password Failure”.
6. Press [0][#] on the telephone to hang up.
7. The control panel will start to dial the next programmed phone number.
Note:
- Refer to page 26 [Receiving the Emergency Call] for more info on how to react
to an emergency call.
- The password is treated as a confirmation of the emergency message. Once a
valid password is entered, the control panel will not call that number again, it
will proceed to the next number.
- If any one of the called parties disarms the control panel, the control panel will
not continue to dial the remaining phone numbers.
- After calling all the programmed phone numbers, the control panel will be back
to the previous operation mode.
–46–
–11–
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
HOME AUTOMATION
Event Trigger
Contact ID Phone number
You can program a telephone number for calling to the central monitoring station.
When the system is in panic, the control panel will call this phone number and
will send out a Contact ID message with event code 140, which represents
“General Alarm”.
You can control up to 5 different devices not only manually, but also automatically. It is
called Event Trigger. That means when a sensor is triggered, the control panel will
transmit a signal to activate the designated control module. Applications include:
- Lights on when you open the front door
(walking into a room, lights on automatically),
this is called "Event Trigger on".
Follow the instructions below to program the necessary info in order to call a
monitoring station:
- Phone number of central monitoring station (up to 29 digits)
- Account number given by the Central Monitoring Station
- Lights off when you open a door. (walk away
from a room, turns lights off), this is called
"Event Triggered off".
Event Trigger On
Phone Number Programming (Calling to Central Monitoring Station)
Event trigger is only applicable to the sensor(s)
and control module in the same zone. For
example, you can program control module 1 to
be on or off when zone 1 sensor(s) is triggered.
You can also program control module 2 to be
on / off when zone 2 sensor(s) is triggered.
Step
1
Keys
Function
Description
Note
3 beeps for valid
password. 1 long
beep for invalid
Enter Program- Enter master
ming mode
Press [PROG]
Press [MPIN]
password to
programming mode
password.
Select phone
number
programming
Factory Default: This feature is disabled for
all zones at the factory.
You will hear
[Enter Phone
Memory]
Press [1]
Press [0]
2
3
Event Trigger Off
To change the event trigger setting follow the instructions below.
You will hear
[Phone Zero]
During emergency,
the Contact ID phone
number has the highest
priority, it will be the
first number to call.
Enter phone
memory
Step
1
Keys
Function
Description
Note
Enter master
password to
programming
mode
3 beeps for valid
password. 1 long beep
for invalid password.
Enter Program-
ming mode
[PROG]
[MPIN]
You will hear
Phone number
can be up to 29
digits.
Enter phone
number
Enter [Phone
number] +
[Arm]
4
Select Event
Trigger
After [7] is entered,
some zone LEDs will be
off, on or flash. This
indicates the setting of
event trigger.
2
[Phone Accepted]
indicating the phone
number has been
programmed
[7]
successfully.
Select which
zone you would
like to enable /
disable event
trigger.
If event trigger “ON” is
Disable Event
Trigger: [1] to
[5]
Refer to the
diagram below
to select the
appropriate
setting.
3
enabled, that zone LED will
be on. If event trigger “OFF”
is enabled, that zone LED
will flash. If it is disabled, the
zone LED will be off. You are
allowed to make multiple
changes before terminating
programming mode.
Enable Event
Trigger: [6] to
[0].
Terminate
programming
mode.
PROGLED
will be off.
[PROG]
when
finished.
4
–12–
–45–
Download from Www.Somanuals.com. All Manuals Search And Download.
HOME AUTOMATION
INSTALLATION
Account Number Programming
ZONE LED
Off
DESCRIPTION
In order to program the account number, follow the procedures follow:
Zone is not occupied by any control module
Flashes twice
That means a remote has occupied that zone.
THIS IS NOTACONTROLMODULE,THEREFORE, SHOULD NOTBE
ERASED.
Step
1
Keys
Function
Enter
Programming
mode
Description
Note
Enter master
password to
programming
Press [PROG]
Press [MPIN]
3 beeps for valid
password. 1 long beep
for invalid password.
Flashes once
That zone is occupied by a control module. You may select this
zone to erase this control module.
mode
Select
password
programming
Press [2]
Press [0]
2
3
Flashes once,
then twice
That means this zone is occupied by a remote AND a control module.
You may select this zone to erase the control module.
Select to
[0] = Add/change
add / change account number
account
number
** Table F: Zone LED status for erasing control module.
Enter new
account
number
Enter [New 4-
digit Account
Number]
Enter the 4-digit
account number
given by the
This number can be a
combination of 0-9,
B,C,D,E & F.
4
Part 2 Erase communication from Control Panel to Control Module
central monitoring
station.
Step
1
Keys
Function
Description
Note
To enter 0-9:
Enter by the keypad 0-9
directly.
Remove the
control module
from the
To enter B,C,D,E,F:
electrical outlet
Press [STATUS] and the
ARM light will stay on.
Then press the following
keys for the correspond-
ing letters (1=B, 2=C, 3=D,
4=E, 5=F).
Control module LED
will flash rapidly
indicating all the
memory is erased.
You may now
Press and hold
the learn button
on the control
module while
plugging in the
control module
to an electrical
outlet.
2
To erase the
memory of the
control module
Press [STATUS] to return
back to number-mode
when you want to input
numbers. The ARM light
will turn off.
release the learn
button.
You can toggle between
the number or letter mode
by pressing [STATUS]
when entering the
Once the memory of the control module is erased, all of its memory is cleared. If
you have other remotes / control panels controlling this control module, you need
to re-program those remotes / control panels.
account number.
Enter the new
account num-
ber again for
confirmation
3 beeps if new account
number is accepted. You
will hear [Password
Accepted]
Enter [New 4-
digit Account
Number]
5
–44–
–13–
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
HOME AUTOMATION
Operation
Deactivating the Digital Dialer
To turn off a light with the control panel:
1. Press the device number button on the control panel, i.e. pressing 1 will turn
off device 1, pressing 2 will turn off device 2.
You can deactivate the digital dialer by erase the phone number memory for
central monitoring station.
2. You will hear [Device X Off], where X is the device number.
3. You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4. If the receiver receives the signal, the control panel will announce [Device
Off Accepted].
Step
Keys
Function
Description
Note
Enter Program- Enter master
ming mode
3 beeps for valid
password. 1 long
beep for invalid
password.
Press [PROG]
Press [MPIN]
1
password to
programming mode
To turn on a light with the control panel:
Press [1]
You will hear:
[Enter Phone
Memory]
Select phone
number
programming
2
1. Press the number below the device number that you would like to turn on, i.e.
pressing 6 will turn on device 1, pressing 7 will turn on device 2.
2. You will hear [Device X On], where X is the device number.
3. You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4. If the receiver receives the signal, the control panel will announce [Device
On Accepted].
Press [0]
Enter phone
memory
3
4
Press [ARM]
You will hear
[Phone Zero
Empty Memory]
indicating the phone
number have been
deleted, the digital
dialer is deactivated.
Confirm delete
the phone
number.
Erase Control Modules
To erase a control module from the control panel, it is similar to learning a
control module, which involves 2 parts.
Note: If no phone number is programmed to call the central monitoring station,
the digital dialer is automatically disabled.
1. Erase the memory of the control panel
2. Erase the memory of the control module
Part 1 Erase the memory of the Control Panel
Step
1
Keys
Function
Enter
Programming password to
Description
Note
3 beeps for valid
password. 1 long beep
for invalid password.
[PROG]
[MPIN]
Enter master
mode
programming mode
Select erase
control
module
After [0] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that zone
is occupied by any control
module. **See Table F
2
3
[0]
programming
To erase an
occupied
control module,
press [1] to [5].
After you have selected the
remote location, you will
hear 3 beeps and verbal
confirmation [Device X
Empty Memory], where
X is the control module
location you have selected.
Refer to the table
below to select
the control
Select the
control module
location you
would like to
erase
module location.
–14–
–43–
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION (ML-100A Only)
HOME AUTOMATION
Installing Door / Window Sensors
Control Module [1] is represented by zone LED 1
Window / Door Sensor is used to monitor doors or windows that
open and close. When these doors / windows are open or
closed, the sensors will transmit a signal to the control panel
to notify the user. These sensors consist of 2 parts, one is the
transmitter, the other is the magnet.
This row
Buttons for
Learning Control Module
:
Transmitter
Magnet
Before installing the sensor, remove the battery isolator by pulling out the yellow
tab. Once the isolator is removed, the corresponding zone LED on the control
panel will flash and buzzer will beep. If the magnetic contact is closed, the
beeping will stop.
Note:
- Both Window/Door Sensors have been programmed at the factory. They are
Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the
beeping and zone LED to determine which one is zone 1 and which is zone 2.
Part 2 Learn signal from Control Panel to Control Module
Step
1
Keys
Function
Enter
Programming
mode
Description
Note
Press and hold
the learn button
on the Control
Module until its
LED starts to
flash.
LED on the Control Module
will flash indicating it is in
learn mode.
Mounting the Sensor
The transmitters should be mounted on the door frame or window frame by
double sided tape. The magnet should be mounted on the door or window by
either double sided tape or screws. Make sure the magnet is aligned with the
red marking on the transmitter. If the surface of the frame is flat enough, double-
sided foam tape is sufficient, otherwise, it is recommended to screw the
mounting plate to the frame, then apply double sided tape. After mounting the
sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the
AAA+ logo is in the upright position.
After [X] is entered, you
will hear [Device X On]
indicating you have trans-
mitted an ON signal for
device X, where X is the
Control Module Location.
The LED on the Control
Module should be off,
indicating it has learned
the signal, you may now
release the learn button
and the LED will stay on
again.
[6] to [0]
Transmit an ON Refer to the
signal for the chart below to
2
selected device determine which
from the Control button [6] to [0]
Panel to the
Control Module. You should
transmit the “ON”
to press.
command for the
selected device.
Double-sided
foam tape
Magnet on the right
Mounting plate
and screws
(optional)
Sensor
Magnet on the left
CONTROL MODULE
LOCATION
TRANSMIT
BUTTON [X]
Testing:
1
2
3
4
5
6
7
8
9
0
After mounting the sensor, test the sensor by opening and closing the door or
window. Open the door or window will result in the followng:
1. Beeping - The number of beep represents the zone number.
2. Zone LED flashing - Number of flash represents the sensor number.
–42–
–15–
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION (ML-100A Only)
HOME AUTOMATION
Part 1 Learn signal from Control Module to Control Panel
2 Single flash
Step
1
Keys
Function
Description
Note
[PROG]
[MPIN]
3 beeps for valid
password. 1 long beep
for invalid password.
Enter Program- Enter master
ming mode
password to
programming
mode
1. Beep___Beep___
Beep___Beep___
............
[4]
Select learn
control module
programming
After [4] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that
zone is already occupied
by another control
2
Note:
- Try to mount the sensors as far away from the floor as possible to avoid
damaging them. Mounting the sensors at a higher position will also result in
better operating range.
module.**See Table E.
[1] to [5]
Select the
location [1], [2],
[3], [4], or [5].
Select control
module location
(Max. 5 control
modules)
After you have selected
the control module location,
that zone LED will be on.
3
- Do not mount the sensor to the exterior of the door / window, always mount the
sensor to the interior side of the door / window to avoid being damaged or
stolen by non-intended users.
Once the signal
is transmitted to
the Control Panel,
that signal will be
stored.
You will hear
Activate the
control module
by pressing its
learn button
Send signal
from control
module to
4
[Device X Accepted],
where “X” is the control
module location.
Installing Motion Sensor
The motion sensor is most suitable for guarding a large area such as living room,
family room, or bedroom. It can also be used to monitor a hallway or stairway.
control panel.
once quickly.
Insert Battery
ZONE LED
DESCRIPTION
Undo the screw on the back of the motion sensor and
remove the battery cover. Connect a 9V alkaline battery
to the battery connector. Please note the polarity.
Off
Zone is not occupied by any control module
Flashes once
This zone is occupied by another control module. Programming
another remote to this zone will overwrite the previous control
module.
If you are planning to install the motion sensor outdoor,
you should reduce the sensitivity by placing the jumper
at location “2”.
For indoor application, if you want to reduce the
sensitivity, you can change the jumper setting to
“2” as well.
Flashes twice
This zone is occupied by a remote. You can still program a control
module to this zone, and it will not overwrite the remote you have
in this zone.
Sensitivity
Flashes once,
then twice
This zone is occupied by a remote AND a controlmodule. If you
program another control module to this zone, it will overwrite the
previous control module, but not the remote.
Jumper Location 1 High Sensitivity
Jumper Location 2 Low Sensitivity
Caution:
** Table E: Zone LED status for learning control module.
Depending on the environment, if you experience a false trigger when the motion
sensor is placed outdoors, you should relocate it or even place it indoors. Wind
blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the
location at where the motion sensor is mounted could cause a false trigger, you
should change the mounting location for such sensor.
–16–
–41–
Download from Www.Somanuals.com. All Manuals Search And Download.
HOME AUTOMATION
INSTALLATION (ML-100A Only)
The Control Panel can be used to control lights and home applicances with a
Control Module, (Control Module is sold separately). Garage door opener can be
controlled with a Garage Door Receiver (sold separately). The Control Panel can
control up to 5 Control Modules / Garage Door Receivers.
For outdoor monitoring, please refer to page 33 to program the motion sensor
to Alert Zone.
You may now close the battery cover and
re-insert the screw.
Mount the ball-head joint on the wall with
screws provided. Slide the back of the
sensor into the ball-head joint. The
mounting angle can be adjusted.
There are 3 ways to control these modules / receivers:
1. Using the keypad on the control panel to
operate these modules / receivers manually
Testing
Walk test should be performed after the motion sensor is
mounted. Walk in the detected area, if motion is detected, a
red light inside the sensor will glow. If the red light does not
glow, motion has not been detected and you may need to
re-position the sensor. Ensure you walk test all the locations
that you would like the motion sensor to cover.
2. Calling in away from home using a touch tone
phone (Refer to “Remote Operation by Telephone”)
Door open
Lights
on
3. Setting up Event Trigger
Note:
DETECTING AREA: (Unit = meter)
(Refer to Advanced Programming)
1.2M
- Perform the walk test after you have inserted the
battery for more than 1 minute.
14
55°
55°
11°
12
10
8
- Before performing the walk test, the sensor should
not detect any motion.
- After motion is detected once, the sensor will not
be triggered unless no motion is detected for 20
seconds. Therefore, wait for at least 20 seconds
during walk testing between 2 activations.
6
27°
22°
22°
4
2
M
These control modules should be programmed to the control panel as device
1 to 5. Please follow the programming instructions below to program these
control modules.
12°
SENSOR
0
1
2
3
4
5
6
7
8
9
10 11 12 13
Learn Control Modules
Caution:
When installing the motion sensor, avoid placing it near heat or cold producing
devices (i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement,
especially caused by changes in temperature may trigger the Motion Sensor and
cause false alarms. Please carefully test your Motion Sensor so that it will only be
triggered by wanted movement.
Both control panel and control module are transceivers, meaning they can transmit
and receive signals from each other. For home automation, the user will initiate an
action from the control panel, such as sending a signal to turn on the light, then the
control module will receive such signal and respond. The control module will then
send back a confirmation to the control panel
to indicate the light has been turned on.
(command
Turn on
You have now successfully installed and programmed the Control Panel and its
sensors. Please follow the rest of the instructions for operations and advanced
programming.
signal)
Therefore, during programming,
Control
Module
it is required to program 2 things:
®
1
2
3
4
5
PWR
ARM
1
2
3
4
5
1. Signal from control module to
control panel (confirmation signal)
6
7
8
9
0
PROG
BATT
ARM
STAT
US
LO
MUTE
Control
Panel
2. Signal from control panel to
control module (command signal)
Confirm on
(confirmation
signal)
–40–
–17–
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED PROGRAMMING
OPERATION
The Control Panel is always in one of the 2 operating modes:
1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.
This row
Buttons for
Sensor 1
:
SENSOR 1 SENSOR 2
Button [1] Button [6]
Zone 1
Zone 2 Button [2] Button [7]
Zone LED :
Flash once
Alert Mode
Button [8]
Button [9]
Button [0]
Button [3]
Button [4]
Button [5]
Zone 3
Zone 4
Zone 5
The Control Panel will be in alert mode automatically if the system is not armed.
Alert mode allows users inside the premises to know what sensor is triggered.
It is intended to be used when someone stays inside the premises.
This row
Buttons for
Sensor 2
:
In alert mode, the control panel will give you notification of the triggered sensor(s)
by voice announcement, unique beeping and LED flashing.
Zone LED :
Flash twice
1
2
Number of beeps
Zone of the triggered sensor
Number of flashes of zone LED Sensor number of the triggered sensor
Erase Sensors
Note:
- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors
can be programmed to the control panel. Please refer to page 37, "Sensor
Location Selection Guide" for detail information.
Proceed to the following to erase a sensor.
Step
1
Keys
Function
Enter
Programming password to
Description
Note
Enter master
[PROG]
[MPIN]
3 beeps for valid password.
1 long beep for invalid
programming mode
password.
Alert Mode Examples (Door/Window sensor sold separately)
mode
Zone 1 Sensor 1
1.
2. Single flash
Beep___Beep___
Beep___Beep .....
2
3
Select erase
remote
programming
[9]
After [9] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that zone
is occupied by any sensor.
**See Table D below.
Select the
Refer to the table
To erase an
occupied
sensor, press
[1] to [0].
After you have selected the
sensor, you will hear 3 beeps
and verbal confirmation
[Zone X Sensor Y Empty
Memory], where X and Y
are the zone and sensor
numbers you have selected.
sensor you below to select the
would like to remote location.
erase
Zone 3 Sensor 2 window
open
2. Double flash
1.
Beep Beep Beep___
Beep Beep Beep___
ZONE LED
Off
DESCRIPTION
Zone is not occupied by any sensor
This zone is occupied by sensor 1.
This zone is occupied by sensor 2.
Note:
-For Door / Window sensor, alert notification (beeping and LED flashing) will
continue until the sensor is in closed position, i.e. closing the window or door.
Flashes once
Flashes twice
-For motion sensor, the alert notification was disabled at the factory default. To
perform the walk test, it requires to enable the Alert Zone (Bypass Zone) feature
in the Control Panel. After the walk test, it needs to disable this alert zone feature
otherwise it will bypass the signal in the alarm mode. Please refer to the page 33,
"Alert Zone" for detail. Please refer to information.
Flashes once,
then twice
This zone is occupied by sensors 1 and 2.
** Table D: Zone LED status for erasing sensors.
–18–
–39–
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
ADVANCED PROGRAMMING
ZONE DEPENDENT FEATURES
SENSOR 1
Location
SENSOR 2
Location
Mute
Beep / Alarm
Beep / Alarm
Auto Mute
Y / N
Event Trigger
Alert
Y / N
zone 1
zone 2
zone 3
zone 4
zone 5
Disabled / On / Off
When the alert beeping becomes undesired, you can terminate the beeping in 3
different ways:
Beep / Alarm
Beep / Alarm
Beep / Alarm
Beep / Alarm
Y / N
Y / N
Y / N
Y / N
Disabled / On / Off
Disabled / On / Off
Disabled / On / Off
Disabled / On / Off
Y / N
Y / N
Y / N
Y / N
1. Mute button - Manual mute by pressing the
mute button
Table C
4. Once you have filled out the table, it should look something like this.
Pressing the mute button will temporary
disable the beeping for all the activated
sensors. For example, if a window with a
window sensor will be open for a long period
of time, the continuous beeping may become
undesired. Pressing the mute button will
temporary disable the beeping for this
ZONE DEPENDENT FEATURES
SENSOR 1
Location
zone 1 Front Door
SENSOR 2
Location
Front Window
Beep / Alarm
Beep / Alarm
Auto Mute
Y / N
Event Trigger
Disabled / On / Off
Disabled / On / Off
Disabled / On / Off
Disabled / On / Off
Disabled / On / Off
Alert
Y / N
Kitchen Motion
Back Door
zone 2
zone 3
Beep / Alarm
Beep / Alarm
Beep / Alarm
Beep / Alarm
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
Y / N
zone 4 Backyard Motion
Basement Water Basement Motion
zone 5
Mute Button
sensor only, it will still beep if other sensors
You may refer to each column representing the zone dependent feature, to program
each zone with the selected feature. For example, Auto Mute feature is only enabled
for zone 3, when you are in the auto mute programming, you should enable this
feature for zone 3 only, the rest of the zones should have this feature disabled.
Repeat this step for all 4 zone dependent features during programming.
are triggered. This sensor will beep again
if this window is closed, and then opened.
Buzzer Mode Selector
2. Change the buzzer mode - Disable Beeping
5. You may now follow the procedure below "Learn Sensor Continue" to program
the sensor(s) to the desired zone(s).
The beeping can be disabled for all
zones by changing the buzzer mode
selector.
Learn Sensors - Continue
Step
Keys
Function
Description
Enter master
password to
Note
3 beeps for valid
password. 1 long beep
for invalid password.
- If the buzzer mode selector is at "I", beeping is enabled.
- If the buzzer mode selector is at "II", beeping is disabled.
Enter Program-
ming mode
[PROG]
[MPIN]
1
programming mode
After [3] is entered, some
zone LEDs will flash
Select learn
sensor
programming
[3]
2
If beeping is disabled, all sensor alert beeping will be disabled, however, the
voice announcement and LED flashing will still function.
once, or twice, some will
be off. The zone LEDs
represent whether that
zone is already occupied
by another sensor.
3. Enable Auto-Mute in Advanced Programming
If this feature is enabled for that zone, beeping will be terminated automatically
after 15 seconds . Refer to "Advanced Programming" - Auto Mute" on page 32
for more information on how to enable this feature.
**See Table D next page.
After you have
selected the zone, that
zone LED will be on.
[0] to [9]
Select sensor
location
Refer to the diagram
below to select the
sensor location, which
includes the zone and
sensor number.
3
4
Trigger sensor
You will hear [Zone X
Sensor Y Accepted],
where X and Y are the
zone and sensor numbers
you have selected.
Activate the
sensor you
would like to
program to
this zone.
Once the sensor is
activated, the signal
will be transmitted
to the Control Panel
which will be stored.
–38–
–19–
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
ADVANCED PROGRAMMING
Learn Sensors
System Status
The control panel continuously monitors the system status as well as all the
sensors status. It will monitor occurrences such as triggered sensors, low
battery sensors, malfunction sensors, or phone line failure etc.
You can program up to 10 sensors to the control panel. There are 5 zones on
the control panel, each zone can program up to 2 sensors. Before program-
ming a sensor, you must decide which sensor location (zone number and
sensor number) you would like to program the sensor to. It is strongly recom-
mended that you refer to “Sensor Location Selection Guide” before deciding
which sensor location you would like to program the new sensors to. Some
features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3)
alert zone , 4) event trigger. Explanation for each feature can be found in the
following pages in Advanced Programming:
In order to check the system status, user can press the “Status” button on the
control panel, voice announcement will be made regarding the system and
sensor status. When the “Status” button is pressed, you will be notified if any of
the following events is occurring:
- System armed or disarmed
- Any triggered sensors
- Any sensors with low battery warning
- Any sensors with failure warning
- Phone line failure
1. Beep/Alarm Setting - Page 29
2. Auto Mute - Page 32
3. Alert Zone - Page 33
4. Event Trigger - Page 45
Refer to page 23 for more details regarding system failures.
Sensor Location Selection Guide
You can program up to 10 sensors to the control panel. There are 5 zones and
maximum 2 sesnors per zone. The 4 features mentioned above are Zone
dependent features meaning both sensors in that zone will operate based on
the setting for that zone. So if you program 2 sensors into one zone, those 2
sensors will react in the same manner for those zone dependent features. For
example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1,
and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a
zone dependent feature for sensor 1 only, but not sensor 2.
Arming the System
You should arm the system when you are the last person to leave the house. By
arming the system, the control panel will call the preprogrammed emergency
phone numbers and the siren will sound when break-in occurs.
Caution: Only arm the system when nobody is expected to be inside the premises.
When someone is expected to be within the premises, the system should not be
armed.
Therefore, the followings are some suggestions of how you should select the
sensor location.
To arm the system, follow the procedures below:
1. Check all the zone dependent features, and determine if you would like to
enable any one of them.
Exit delay 45 seconds
BeepBeep
45 seconds later
ARM LED on.
System
Armed
OR
2. If you decide not to enable any zone dependent features and keep the
factory default setting, you can simply program the sensor to any sensor
location based on your own preference. Omit the following steps and
proceed to "Learn Sensor - Continue".
1. Press [Arm] on the control 2. Leave the premises 3. After 45 seconds.
panel or keychain remote. within 45 seconds.
System will be armed.
3. If you decide to enable some of the zone dependent features, check Table C
below. Circle the zone dependent feature selections. If there are features
that you would like to enable for more than 2 sensors, you need to select
more than one zone for those features.
1. Press [Arm] button on the control panel when no sensors are triggered.
You can also use the keychain remote to arm the system by pressing arm
button on the remote.
–20–
–37–
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED PROGRAMMING
OPERATION
Remote [6] is represented by zone LED 1
Note:
- The control panel cannot be armed if there are triggered sensors. Make sure
all sensors are in closed position, i.e. (close all doors, windows, no movement
should be detected etc).
- The control panel can be armed if there are sensors with low battery or failure
warning.
®
REMOTE LOCATION
6
ZONE LED
1
2
3
4
5
7
8
9
0
2. After pressing the “ARM” button, the “ARM” LED will flash and you will have 45
seconds to leave the premises, this is called the exit delay. You will hear
beeping during the exit delay interval. The beeping rate will change from slow
to fast, the faster the beep rate, the less time you have left to leave the premises
before the siren sounds.
Erase Keychain / Keypad Remotes
3. When the exit delay expires, the control panel will announce “System Armed”,
beeping will stop and the ARM LED will be on steadily. This indicates the
system is now armed.
Follow the instructions below to erase keychain or keypad remotes / receivers.
Step
1
Keys
Function
Description
Note
[PROG]
[MPIN]
Enter master
password to pro-
gramming mode
3 beeps for valid
password. 1 long beep
for invalid password.
Enter
Programming
mode
Note:
The control panel can also be armed remotely when nobody is home, with a touch
tone phone. Please refer to “Remote Operation by Telephone” on page 27.
2
Select erase
remote
After [0] is entered, some
zone LEDs will flash or stay
off. The zone LEDs
represent whether that zone
is occupied by any remote.
** See Table B below.
[0]
programming
Disarming the system
If a sensor is triggered while the control panel is armed, such as entering a house
with an armed control panel, an entry delay will be triggered. User is allowed to
disarm the control panel during the 30-second entry delay. If the control panel is
not disarmed within 30 seconds, siren will sound immediately and emergency
calls will be made. To disarm the control panel, follow the instructions below.
After you have selected the
remote location, you will hear 3
beeps and verbal confirmation
[Device X Empty Memory],
where X is the remote location
you have selected.
Select a remote
location [6], [7],
[8], [9] or [0].
Select remote
location you
would like to
erase
To erase
3
an occupied
remote, press
[6] to [0].
Entry delay 30 seconds
BeepBeep
Arm LED off
System
Arm LED flashes
BeepBeep
ZONE LED
Off
DESCRIPTION
Zone is not occupied by any remote
OR
Disarmed
Flashes twice
This zone is occupied by a remote. You may select this zone to
erase this remote.
Flashes once
This zone is occupied by a control module (Optional).
THIS IS NOTAREMOTE CONTROL, THEREFORE, SHOULD NOTBE
ERASED. (Refer to page 43 Erase Control Module for more
information)
3. Once the system is
disarmed, the Arm
LED will be off.
1.Entering the premises
will trigger the entry
delay.
2.Enter password within
30 seconds or press the
disarm button on the
keychain remote.
Flashes once,
then twice
This zone is occupied by a remote AND a control module.
You may select this zone to erase the remote.
1. During the entry delay, the system will beep for 30 seconds, the ARM LED will
flash during this entry delay interval. The faster the beep, the less time you
have left to disarm the control panel before the siren sounds.
** Table B: Zone LED status for erasing keychain/keypad remote(s).
* Please refer to erase control module on page 43.
–36–
–21–
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED PROGRAMMING
OPERATION
2. You must enter a valid password, either the Master Password, or Secondary
Password to disarm the system before entry delay expires.
Learn Keychain / Keypad Remotes
Additional keychain or keypad remotes can be programmed to the control panel.
Maximum of 5 keychain/keypad remotes can be programmed to the control panel.
3. When a valid password is entered, you will hear “System Disarmed” and the
entry delay beeping will stop, the ARM LED will be off.
- Keychain or keypad remotes should be programmed to Device 6 to Device 0.
Note:
- The control panel can also be disarmed remotely when nobody is home, with a
touch tone phone. Please refer to “Remote Operation by Telephone” on page 27.
Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8,
9, or 0, which is the bottom row of the numeric keypad of the control panel.
Step
1
Keys
Function
Description
Note
- If 3 consecutive incorrect passwords are entered, alarm will sound immediately,
the control panel will be in panic mode, and start calling the emergency phone
numbers.
3 beeps for valid
password. 1 long beep
for invalid password.
Enter master
password to
programming mode
Enter Program-
ming mode
[PROG]
[MPIN]
Select learn
remote
programming
After [4] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that
zone is already occupied
by another remote.
[4]
2
Disarming a triggered control panel
If "System Panic" is announced from the control panel after it has been disarmed,
that means the alarm was triggered when it was in armed mode. Follow the
procedures below to set the control panel back to standby mode.
** See Table A below.
Select remote Select a remote
location
location [6], [7],
(Max. 5 remotes) [8], [9] or [0].
After you have selected
the remote location, that
zone LED will be on.
[6] to [0]
1. If the alarm was caused by sensor(s), there will be flashing LEDs and
beeping indicating which sensor(s) triggered the alarm. You may want to
check the condition of the triggered sensor(s), the sensor(s) may be damaged
if there were break-ins.
2. You need to reset the sensor manually by triggering it twice, i.e. open and
then close a door / window sensor, or walk in front of the motion sensor. The
LED representing that sensor will stop flashing after it receives the signal
from the sensor.
3
4
Trigger remote
Once the signal is
transmitted to the
Control Panel, that
signal which will
be stored.
Activate the
remote by
pressing any
one of the
buttons.
You will hear
[Device X Accepted],
where “X” is the remote
location.
3. You must now enter the password again on the control panel or press the
disarm button on the keychain remote, as an acknowledgement of the alarm
event. This will set the control panel back to standby mode.
ZONE LED
Off
DESCRIPTION
Zone is not occupied by any remote
Flashes twice
This zone is occupied by another remote. Programming another
remote to this zone will overwrite the previous remote.
Disarming under Duress
Flashes once
This zone is occupied by a control module* (Optional).
You can still program a remote to this zone, and it will not overwrite
the control module* you have in this zone. (Refer to page 40 Home
Automation for more information)
If you are forcibly compelled to disarm the control panel, you may enter the Duress
Password. Entering the duress password will terminate the entry delay, i.e. no
more entry delay beeping. But the control panel will silently call the emergency
phone numbers for help. The called party will hear the voice announcement
“System Panic”.
Flashes once,
then twice
This zone is occupied by a remote AND a control module*.
If you program another remote to this zone, it will overwrite the
previous remote, but not the control module*.
Note:
- The default duress password is [3838].
** Table A: Zone LED status for learning keychain/keypad remote(s).
* Please refer to learn control module on page 40.
–22–
–35–
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED PROGRAMMING
OPERATION
Panic
To enable alert zone feature, follow the instructions below.
Pressing the panic button on the control
panel or keychain remote will cause the
siren to sound and outgoing calls will
be made to the preprogrammed phone
numbers, “System Panic” will also be
announced. This can be used in any
emergency situation.
Step
Keys
Function
Description
Note
OR
[PROG]
[MPIN]
Enter Program- Enter master
ming mode
1
3 beeps for valid
password. 1 long beep
for invalid password.
password to
programming mode
After [8] is entered,
some zone LEDs will
flash or stay on. This
indicates whether alert
zone is selected.
Select Alert
Zone.
[8]
2
3
To stop the siren and disarm the system, user can enter a valid password, or
press the disarm button on the keychain remote. This will terminate the siren
and the control panel from calling the rest of the emergency phone numbers.
Disable
Alert Zone: zone you
[1] to [5]
Select which
Refer to the
diagram below to that zone LED will be on.
select the
appropriate
setting.
If alert zone is selected,
would like to
select as Alert
Zone.
If it is not selected, the
LED will flash. You are
allow to make multiple
changes before terminat-
ing programming mode.
Enable
Alert Zone:
[6] to [0].
ARM
DISARM
PANIC
AUX
Terminate
programming
mode.
[PROG]
when
finished.
PROG LED will be
off.
4
- Control other Skylink receiver
such as Garage Door Receiver
System Failure
Control Panel constantly monitors itself and its sensors. If there are any trouble
conditions, the control panel will advise the user. These trouble conditions include:
®
DISABLE
ALERT ZONE ALERT ZONE
ENABLE
This row
Buttons to
Disable Alert Zone
:
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
Zone 1 Button [1]
- Phone Line Failure
Zone 2
Button [2]
Zone LED : Flash
- Sensor Failure (loss of supervisory signal)
- Low Battery – Control Panel
- Low Battery – Sensors
Zone 3 Button [3]
Zone 4
Button [4]
This row
Buttons to
:
Zone 5
Button [5]
Enable Alert Zone
Phone Line Failure
Zone LED : ON
When the phone line is disconnected or malfunctions, the control panel will
instantly notify the user by:
1. Both Power [PWR] and Program [PROG] LEDs will flash together;
2. Voice announcement “Phone Line Failure” will be played.
When phone line failure occurs, please check the phone line connection, ensure
the phone line is plugged into both the control panel and the wall socket securely.
You should also check the phone line with a normal telephone to determine if it
can dial out to a phone number. If it cannot dial out, that indicates the phone line
is not in service, you should contact your local phone company.
–34–
–23–
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
ADVANCED PROGRAMMING
Sensor Failure
The control panel constantly monitors its sensors, if the control panel fails to
communicate with any sensors, it will notify the user by:
ENABLE
AUTO MUTE
DISABLE
AUTO MUTE
This row
:
Buttons to
Disable Auto Mute
Zone 1
Zone 2
Button [6]
Button [1]
1. The zone LED of the failed sensor will be on steadily;
2. Voice announcement “zone X sensor Y failure” will be played.
Zone LED : Flash
Button [2] Button [7]
Zone 3
Zone 4
Zone 5
Button [8]
Button [9]
Button [0]
Button [3]
Button [4]
Button [5]
When sensor failure occurs, try the following:
This row
Buttons to
Enable Auto Mute
:
1. Check if the sensor is located at where it should be, and whether there is any
physical damage to the sensor.
Zone LED : ON
2. If the failed sensor is not physically damaged, try to activate the sensor and see
if the control panel reacts to such activation.
3. If not, try to remove the sensor from its location, and bring it closer to control
panel and activate the sensor. It is possible that the sensor is installed too far
from the control panel and it cannot establish a steady communication with the
control panel. If this is the case, please install the sensor closer to the control
panel.
Alert Zone (Bypass Zone)
As explained earlier, the control panel can operate in 2 different modes, 1) Alert
Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control
panel will either give a 30 seconds entry delay, or siren will sound immediately
(with instant alarm). However, there are sensors that you do not want to trigger
the alarm when the system is armed. Such as an outdoor sensor, or any other
sensors that you only want to give you alert notification. Under such circum-
stances, zone(s) can be programed to react only when the control panel is in
alert mode, these zones will be automatically bypassed when the control panel
is in alarm mode. These zones can also be considered as "Bypass zones".
Low Battery
Control Panel
The control panel is powered mainly by the adapter. However, during power outage,
it will be powered by the rechargeable backup battery. Under standby conditions,
these batteries can last for 48 hours.
It is recommend to enable alert zone if:
When the backup battery is running low, the “LO BATT” LED on the control panel
will be on, indicating the backup battery should be recharged. To recharge the
backup battery, plug in the power adapter. It takes approx. 20 hours to fully charge
the backup battery.
- You do not consider the sensors in that zone an emergency
- Sensors in that zone are located outdoors
- When nobody is at home, you do not want to know the status of the sensor(s) in
that zone
Sensors (For ML-100A Only)
Factory Default: This feature was disabled for all zones at the factory.
All of the sensors are battery powered. Depending on the operating condition
and environment, the battery life varies from 9 months to 2 years. 9V alkaline
battery is used for the motion sensor, the battery life is approximately 9 months.
Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of
approximately 2 years. For other sensors, please refer to the user’s instructions
regarding the battery life.
–24–
–33–
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
ADVANCED PROGRAMMING
When the sensor is running low in battery, the sensor will send a wireless low
battery signal to the control panel. The zone LED representing that sensor will be
on steadily, indicating sensor(s) in that zone is in trouble condition. Control Panel
will also have an announcement to advise the user the trouble condition is low
battery, such as “zone X sensor Y low battery”, where X and Y represent the zone
and sensor number. Please replace the battery of that sensor.
Auto Mute
When a sensor is triggered in alert mode, audio warning will be emitted, either
beep or alarm. For example, if a door is opened, the beep will not stop until the
door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.
There are times that this is not desired. With the auto mute feature enabled, the
beep will go on for only 20 seconds. After that, even if the sensor remains open,
the beep will stop only the zone LED will flash to indicate the sensor is triggered.
Beep will go on again if the sensor is closed and opened again.
Keychain Remote (For ML-100A Only)
The battery of the keychain remote (Alkaline, Type 23A, 12V) needs to be replaced
when either one of the followings occurs:
Note: Auto Mute only functions when the control panel is in alert mode (disarmed).
If the control panel is in alarm mode (armed), a triggered sensor will result in
entry delay or instant alarm.
1. The LED on the keychain doesn’t flash or on when a key is pressed; or
2. The operating range starts to decrease.
Factory Default: This feature was disabled for all zones at the factory.
To replace the battery:
To enable auto mute feature, follow the instructions below.
1. Undo the two screws on the back of the transmitter.
The bottom case will then come off.
2. Using a small screwdriver or pen, pry out the old
battery from one end.
Step
Keys
Function
Description
Note
[PROG]
[MPIN]
Enter Program-
ming mode
Enter master
password to
3 beeps for valid
password. 1 long beep
1
3. Place the new battery in position. A diagram in the
battery compartment indicates which end is positive
and which is negative.
programming mode for invalid password.
Select Auto Mute
Enable / Disable
After [6] is entered, some
zone LEDs will flash or
stay on. This indicates
whether Auto Mute is
enabled or disabled.
[6]
2
3
4. Close the battery cover and reinsert two screws.
-
If auto mute is enabled,
that zone LED will be on.
If it is disabled, the LED
will flash. You are allow
to make multiple changes
before terminating
Disable
Select which
Refer to the diagram
Auto Mute: zone you would below to select the
+
[1] to [5]
like to enable /
disable auto mute.
appropriate setting.
Enable
Auto Mute:
[6] to [0].
programming mode.
Terminate
programming
mode.
PROG LED will be off, and
you will hear 3 beeps.
[PROG]
when
finished.
4
–32–
–25–
Download from Www.Somanuals.com. All Manuals Search And Download.
COMMUNICATION
ADVANCED PROGRAMMING
Receiving the Emergency Call
Follow the procedures below to program the beep / alarm setting.
If you are on the list as one of the recipients of the emergency call, you should read
the following instructions carefully. You should also notify all the persons you will
be calling so they know how to react when they receive the emergency call.
Step
1
Keys
Function
Description
Enter master
password to
Note
[PROG]
[MPIN]
EnterProgramming
mode
3 beeps for valid password.
1 long beep for invalid
programming mode password.
The control panel will call you when there are emergencies such as break-ins,
smoke, fire events, or someone at home needs assistance.
Select Beep /
Alarm Setting
After [5] is entered, some zone
2
3
[5]
LEDs will flash or stay on.
This indicates whether that
zone is set to beep or alarm.
1. When the phone rings at the calling location, the person who answers the
phone will hear a message related to the emergency events, such as
“System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be
repeated several times depending on how it was programmed.
Select which
Refer to the
zone you would diagram below to
Set to Beep:
[1] to [5]
If Alarm is set for that zone,
that zone LED will be on. If
Beep is set, the LED will
flash. You are allowed to
make multiple changes before
terminating programming
mode.
like to Beep or
Alarm.
select the appro-
priate setting.
Set toAlarm:
[6] to [0].
2. After the message has been repeated for
a certain number of times, the control panel
will ask for a valid password, you will hear
“Enter Password”.
PROG LED will be off, and
you will hear 3 beeps.
Terminate pro-
gramming mode.
[PROG] when
finished.
4
Zone 1
Sensor 1
®
Triggered
BEEP
ALARM
3. Enter the 4-digit password to have access
This row
:
Button [1] Button [6]
Zone 1
to the control panel. If a valid password is
accepted, you will hear “Password Accepted”,
otherwise, you will hear “Password Failure”.
Buttons for Beep
Zone 2 Button [2] Button [7]
Zone LED : Flash
Button [8]
Button [9]
Button [0]
Button [3]
Button [4]
Button [5]
Zone 3
Zone 4
Zone 5
Enter
Password
This row
:
Buttons for Alarm
4. After entering the correct password, you
can follow the “Phone Command” instruc-
tions to perform the required tasks, such
Zone LED : ON
as disarm, turn on / off devices or check the
-Arm
system status etc. For further information
-Disarm
-Check status
of how to control the system remotely,
-Control lighting etc.
Example:
please refer to the next section, "Remote
-Disconnect
If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply
Operation by Telephone".
press [0] at step 3.
This will change the zone 5 setting to “Alarm”.
–26–
–31–
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED PROGRAMMING
COMMUNICATION
Remote Operation by Telephone
System Armed (Alarm Mode)
If a zone is set to “Beep”, the control panel will give entry / exit delay.
If a zone is set to “Alarm”, the siren will sound immediately without entry delay
The control panel can be operated while you are away from home. You can
have access to the control panel with any touch tone phone to perform a variety
of operations, listed below.
- Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with
the alarm setting on, the siren will sound immediately without entry delay, it is
called “Instant Alarm”. The siren will not stop until the siren timeout or a valid
password is entered. Control panel will call the emergency phone numbers to
notify the users of the alarm situation.
- Arm
- Disarm
- Lights, Home Applicances on / off (Requires additonal Control Module)
- Garage door open / close (Requires additional Garage Door Receiver)
- System status
- Disconnect
When a sensor is triggered, there are 4 options:
ZONE SETTING
There are 2 ways you can have access to the remote phone operation:
OPERATING MODE
Disarmed (Alert)
Armed (Alarm)
BEEP
ALARM
1. You can call the control panel when you are away from home; or
2. When the control panel calls you during emergency.
1) Beep
2) Alarm sounds immediately
3) Entry / Exit Delay
4) Alarm sounds and calls
preprogrammed phone
numbers immediately
To access the control panel away from home
Calling in when you are away from home
Factory Default: All zones were programmed to Beep at the factory.
You may consider to programming the zone(s) into Alarm mode if:
1. Call your home phone number, or the number that the phone line of the control
panel is connected to.
2. Hang up after the second ring.
- You need immediate attention if that sensor is triggered, such as flood sensor,
smoke sensor etc.
- The sensor will not be triggered on a daily basis, such as a door that you
normally will not open, and if it opens, you would like to know immediately.
3. Wait at least 10 seconds, but not more than 40 seconds, then call the phone
number again.
4. The control panel will pick up the phone call and request for a valid user
password, you will hear “Enter Password”. You can enter either the Master
Password or Secondary Password. If the password is correct, you will hear
“Password Accepted”, otherwise, you will hear “Password Failure”.
Caution:
It is not recommended to program an outdoor sensor to Alarm mode, which may cause
false alarm. For outdoor sensors, they should be programmed into an Alert Zone,
please refer to page 33 for details.
5. Once the password is accepted, you can have access to all the operations
listed below.
–30–
–27–
Download from Www.Somanuals.com. All Manuals Search And Download.
COMMUNICATION
ADVANCED PROGRAMMING
Advanced Programming allows users to customize the control panel to react
differently under different conditions. Features such as:
Table 1: Remote Phone Operations
SYSTEM OPERATION
PHONE COMMAND
DESCRIPTION
- When a sensor is triggered, the control panel can beep or alarm
- Beeping can be terminated automatically after a fixed period of time for some sensors
- Some sensors can be programmed to beep only, never alarm
- When a door is open, turn lights on
Turn on device x
[x] = 1 to 5
x+[*]
Turn devices on will hear [Device X On]. When the
control module receives the on signal, it will turn on the
plugged in device, and send a confirmation back to the
control panel. You will then hear [Device On Accepted].
- Program additional sensors and remotes
x+[#]
Turn off device x
x = [1 to 5]
Turn devices off will hear [Device X Off]. When the
control module receives the off signal, it will turn off the
plugged in device, and send a confirmation back to the
control panel. You will then hear [Device Off Accepted].
Programming Summary
COMMAND
[PROG] + [1]
[PROG] + [2]
[PROG] + [3]
[PROG] + [4]
[PROG] + [5]
[PROG] + [6]
[PROG] + [7]
[PROG] + [8]
[PROG] + [9]
[PROG] + [0]
DESCRIPTION
Program Phone Numbers
Program Password
Check system status
Arm
You will hear system status announcement
You will hear [System Armed]
You will hear [System Disarmed]
Phone line disconnect
[8]+[#]
[7]+[#]
Learn Sensors
[9]+[#]
[0]+[#]
Disarm
Learn Keychain or Keypad Transmitters / Control Modules
Beep / Alarm Setting
Disconnect
Auto Mute Setting
Event Trigger Setting
Alert Zone (Bypass) Setting
Erase Sensors
Erase Keychain or Keypad Transmitters / Control Modules
Follow the instructions below to have access to Advanced Programming.
Beep / Alarm
User can customize the audio warning so that when a sensor is triggered, the
control panel may beep or alarm may sound instantly. Depending on whether the
control panel is armed or disarmed, the audio warning is different.
System Disarmed (Alert Mode)
If a zone is set to “Beep”, the control panel will beep when a sensor is triggered,
until the sensor is deactivated. Motion Sensor activation will not cause any
beeping unless the zone for the motion sensor is programmed as a "Bypass
Zone" (see page 33).
If a zone is set to “Alarm”, alarm will sound instantly when a sensor is triggered.
Alarm will stop when the sensor is deactivated, or reaches a 3-minute time out period.
–28–
–29–
Download from Www.Somanuals.com. All Manuals Search And Download.
|