Milwaukee Outdoor Fireplace LMDVT 3328CNM User Manual

care and operation  
instructions  
DIRECT VENT MERIT™  
LMDV-33/35/40 SERIES  
WarninGs  
direct-Vent Gas FirepLace Heaters  
p/n 875,028M reV. e 02/2008  
• Hot! do not touch! the glass and  
surfaces of this appliance will be hot  
during operation and will retain heat  
forawhileaftershuttingofftheappli-  
ance. severe burns may result.  
• carefully supervise children in the  
same room as appliance.  
MODELS  
Millivolt Models  
Electronic Models  
LMdVt-3328cnM  
LMdV-3530cnM  
LMdV-3530cpM  
LMdV-4035cnM  
LMdV-4035cpM  
LMdVt-3328cne  
LMdVr-3328cne  
LMdV-3530cne  
LMdV-4035cne  
• if small children are present in the home, it is  
recommended that this appliance be tted with  
a screen door or screen panel kit. see Pages  
13 & 14 for ordering information.  
LMdVt-3328cpM  
LMdVr-3328cnM  
LMdVr-3328cpM  
instaLLer: Leave this manual with the appliance.  
consuMer: retain this manual for future reference.  
WarninG:iFtHeinForMationintHisManuaL  
is not FoLLoWed eXactLY, a Fire or eXpLo-  
sionMaYresuLtcausinGpropertYdaMaGe,  
personaL inJurY or Loss oF LiFe.  
aVertisseMent: assureZ-Vous de Bien  
suiVreLesinstructionsdonnÉdanscette  
noticepourrÉduireauMiniMuMLerisQue  
d'incendie ou pour ÉViter tout doMMaGe  
MatÉrieL, toute BLessure ou La Mort.  
do not store or use gasoline or other ammable  
vapors or liquids in the vicinity of this or any  
other appliance.  
pour Votre sÉcuritÉ: ne pas entreposer ni  
utiliser d'essence ni d'autre vapeurs ou liquides  
inammables dans le voisinage de cet appareil ou  
de tout autre appareil.  
WHat to do iF You sMeLL Gas:  
• do not light any appliance.  
• do not touch any electrical switch; do not  
use any phone in your building.  
• immediately call your gas supplier from a  
neighbors phone. Follow your gas supplier's  
instructions.  
pour Votre sÉcuritÉ: Que faire si vous sentez  
une odeur de gaz:  
• ne pas tenter d'allumer d'appareil.  
• ne touchez à aucun interrupteur. ne pas vous  
servir des téléphones se trouvant dans le bati-  
ment où vous vous trouvez.  
• evacuez la piéce, le timent ou la zone.  
• appelez immédiatement votre fournisseur de  
gaz depuis un voisin. suivez les instructions  
du fournisseur.  
• if your gas supplier cannot be reached, call  
the re department.  
installation and service must be performed by  
a qualied installer, service agency or the gas  
supplier.  
• si vous ne pouvez rejoindre le fournisseur de  
gaz, appelez le service dos incendies.  
otL report no. 116-F-31-5  
US  
L'installation et service doit être ecuté par un  
qualiéinstalleur, agencedeserviceoulefournis-  
seur de gaz.  
A French manual is available upon request. Order P/N 875,028CF  
Ce manuel d’installation est disponible en francais, simplement en  
faire la demande. Numéro de la pièce 875,028CF  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas pressure -  
Atthetimeofinstallation,itmustbedetermined  
if the appliance needs to be derated. Contact  
yourlocalgassupplierforderationrequirements  
for your area.  
Gas controls/control compartment  
Tables 4, 5 and 6 show the appliances' gas  
pressure requirements.  
access  
Thegascontrolscanbefoundbehindthecontrol  
compartment access door.  
inlet Gas supply pressure  
(all models)  
deration - At higher elevations, the amount of  
BTU fuel value delivered must be reduced by  
eitherusinggasthathasbeenderatedbythegas  
company or by changing the burner orifice to a  
smallersizeasregulatedbythelocalauthorities  
having jurisdiction and by the (USA) National  
Fuel Gas Code NFPA 54/ANSI Z223.1 - latest  
edition or, in Canada, the CAN1-B149.1 and .2  
codes - latest edition.  
removing control compartment door:  
Openthedoorby gentlyliftintitupwarduntilthe  
hook catches on boths sides clear the locating  
slots. Then pull door out to remove.  
Fuel #  
Minimum  
Maximum  
5.0" Wc  
(1.24 kpa)  
10.5" Wc  
(2.61 kpa)  
natural Gas  
11.0" Wc  
(2.74 kpa)  
13.0" Wc  
(3.23 kpa)  
propane  
On millivolt systems, the piezo igniter, HI/LO  
flame adjustment knob, and pilot and main  
gas OFF/ON control knob are located below  
the glass panel enclosure. The gas valve for  
electronic systems is also located below the  
glass enclosure panel. See Figure 1.  
Table 4  
Manifold Gas supply pressure  
Burner orice sizes  
elevation 0-4500 feet ( 0-1372 meters)  
(millivolt models)  
Fuel #  
Low  
High  
natural  
propane  
reinstalling control compartment door:  
Toreinstall,insertthehookcatchesoneachside  
of the door into the corresponding slots in the  
controlcompartmentopening,thengentlypush  
forward and slide down until it locks in place.  
Model  
series  
natural (Lo) 2.2" Wc  
(Hi) 3.5" Wc  
(.87 kpa)  
Gas  
Gas  
drill size  
(inches)  
drill size (inches)  
Gas  
(.55 kpa)  
(Lo) 6.3" Wc (Hi) 10.0" Wc  
(1.57 kpa) (2.49 kpa)  
propane  
#45 (.082")  
39L66 •  
1.2 mm (.048")  
*
*
*
*
LMdVt-3328  
LMdVr-3328  
99K78 •  
Table 5  
#44 (.086")  
60J80 •  
#55 (.052")  
19L52 •  
*
LMdV-3530  
Lift the Lower control  
Manifold Gas supply pressure  
compartment door  
openinG controL  
coMpartMent door  
#37 (.104")  
24M10 •  
1/16" (.0625")  
*
up and pull out to  
(electronic models)  
LMdV-4035  
21L01 •  
remove.  
Fuel #  
Fixed  
* Standard size installed at factory  
• Part /Cat. Number  
3.5" Wc  
(.87 kpa)  
Hook catch  
natural Gas  
Table 7  
control Valve  
10.0" Wc  
out  
propane  
(2.49 kpa)  
Burn-in period  
up  
Table 6  
Lower control  
During the first few fires of this appliance there  
will be some odor due to the curing of the  
paint and burning off of lubricants used in the  
manufacturing process.  
compartment door  
Test gauge connections are provided on the  
frontofthemillivoltgascontrolvalve,identified  
IN for the inlet and OUT for the manifold side  
(see Figures 4 or 5 on Page 4). A 1/8" NPT  
Test gauge connection is provided at the inlet  
andoutlet(manifold)portsontheelectronicgas  
control valve (see Figure 3 on Page 4).  
Figure 1  
Depending on your use, the burn-in period may  
take a few hours or a few days.  
operation and care oF Your  
appLiance  
The standard controls for appliance opera-  
tion are located behind the panel below the  
appliance front glass enclosure panel (see  
Figure 1). Optional control switches are also  
available (see Page 13 - Remote Wall Switch,  
Remote Control or Wall Thermostat).  
Keep Your House WeLL VentiLated  
durinG tHe curinG process. tHe odor  
and HaZe eMitted durinG tHe curinG  
process can Be Quite noticeaBLe and  
MaY set oFF a sMoKe detector.  
These appliances must be isolated from the  
gas supply piping system (by closing their  
individual manual shut-off valve) during any  
pressure testing of the gas supply piping  
systemattestpressuresequaltoorlessthan  
1/2 psig (3.5 kPa).  
If an optional blower is installed, Do not turn it  
on during the Burn-In period.  
Operation of millivolt and electronic gas con-  
trol systems are different. Before lighting and  
operatingyourappliancedetermineifyouhave  
a millivolt or electronic appliance. Familiarize  
yourself with the gas control valve that your  
appliance uses. Refer to Figure 1 for access  
to the gas control valve.  
Theseappliancesandtheirindividualshut-off  
valves must be disconnected from the gas  
supply piping system during any pressure  
testing of that system at pressures greater  
than 1/2 psig (3.5 kPa).  
A white film may develop on the glass front  
during the first few fires as part of the curing  
process. The glass should be kept clean during  
thersttwoweeksofusetopreventthelmfrom  
baking on (making it very difficult to remove).  
See Cleaning Glass on Page 5.  
orice sizes - sea Level to High altitude  
(all Models): These appliances are tested and  
approvedforinstallationsatelevationsof0-4500  
feet (0-1372 meters) above sea level using the  
standard burner orifice sizes (marked with an  
"*" in Table 7).  
note: diaGraMs & iLLustrations are not to scaLe.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Millivolt appliances - Appliances with  
Millivolt systems will be fitted with the gas  
control valve shown in Figures 4 or 5.  
electronic appliances -  
Ifyourelectronic applianceis equippedwith an  
optionalremotewallswitchorremotecontrolkit  
theappliancemainburnermaybeturnedonand  
off with the wall switch or remote control.  
Tolightelectronicappliancesrefertothedetailed  
lighting instructions found on Pages 20 & 21  
of these instructions. Electronic appliance  
lighting instructions may also be found on the  
pull out lighting instruction labels attached to  
the gas control valve.  
electronic appliances - Appliances with  
electronic systems will be fitted with the  
electronic valve shown in Figure 3.  
If your electronic appliance is not equipped  
with a wall switch or remote control, the main  
burner must be turned off and on with the gas  
control switch. Toggle the switch from ON to  
OFF to operate the main burner .  
Millivolt appliances - To light millivolt appli-  
ances refer to the detailed lighting instructions  
found on Pages 18 & 19 . Millivolt appliance  
lighting instructions may also be found on the  
pull out lighting instruction labels attached to  
the gas control valve.  
Honeywell Electronic Gas Valve  
Variable Flame Height adjustment  
(Millivolt appliances only)  
Manifold pressure on/oFF switch  
port  
inlet  
1. All Millivolt appliances are equipped with a  
variable gas control valve. Flame height for  
these models may be adjusted through a  
range between fixed low and high settings  
while the appliance is in operation. Adjust  
the flame height as desired after lighting the  
appliancebyrotatingthevariableadjustment  
control knob (HI/LO) located on the front of  
the valve (refer to Figures 4 & 5 ).  
pressure  
port  
Millivolt appliances are fitted with an OFF/ON  
Rocker Switch located behind the control  
compartment access door, below the appli-  
ance front glass enclosure panel (see Figure 2  
for location). Once the pilot is lit, the OFF/ON  
rockerswitchwillcontroltheapplianceOFF/ON  
burneroperation. Tooperate: Toggletheswitch  
between its ON and OFF positions.  
electronic Gas  
control Valve  
2. During the first initial burns of these appli-  
ances, there will be some odor emitted (see  
Burn-In Period on Page 3 ).  
Figure 3  
If your millivolt appliance is equipped with an  
optional remote switch kit (wall switch, remote  
control or wall thermostat) and the pilot is lit,  
the appliance main burner may be turned on  
and off using the optional switch. When using  
anoptionalremoteswitch,turnoffthestandard  
OFF/ON switch.  
Hi/Lo Variable  
inlet pressure tap  
Flame Height  
adjustment  
Manifold pressure tap  
Gas  
inlet  
T
O U I N  
I
H
F
O
F
Note:Topreventexcessiveresistanceinburner  
circuit(whichcancauseburneroperationprob-  
lems),onlyoneburnercontrolswitchshouldbe  
wired to valve. Therefore, if an optional control  
switch is installed, the standard Off/On switch  
and wires should be removed.  
P
I
L
O
L
W
O
T
O
N
Gas  
outlet  
pilot adjustment  
screw  
P
I
L
terminals  
piezo igniter  
tptH,tp & tH  
Main Gas  
control Knob  
oFF/piLot/on  
piezo igniter  
OptionalBurnerOFF/ON  
Rocker Switch  
sit Gas Valve  
OptionalBlowerOFF/ON  
Rocker Switch  
Figure 4  
SIT Millivolt Gas Valve  
Gas  
outlet  
inlet pressure tap  
Manifold pressure piezo igniter  
tap  
shown with control  
compartment door  
removed  
Honeywell  
Gas Valve  
F
T
F
O
LO  
piezo igniter  
I
H
I
P
O
L
N
O
sit and Honeywell Millivolt Gas Valve  
showing piezo igniter Location (each unit is  
equipped with only one of these Gas Valves)  
piezo igniter  
Gas  
inlet  
Figure 2  
Main Gas  
Hi/Lo Variable  
control Knob  
Flame Height  
OptionalBlowerOFF/ON  
oFF/piLot/on  
adjustment  
Rocker Switch  
OptionalBurnerOFF/ON  
Rocker Switch  
Honeywell Millivolt Gas Valve  
Figure 5  
note: diaGraMs & iLLustrations are not to scaLe.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
If the venting system is disassembled for any  
reason, a qualified service technician should  
follow vent installation instructions for proper  
reassembly and proper sealing of the venting  
system components. However, more frequent  
periodic inspections and cleanings should be  
performed by the homeowner.  
3. Keep the lower control compartment clean  
by vacuuming or brushing at least twice a  
year. Morefrequentcleaningmayberequired  
duetoexcessivelintfromcarpeting,bedding  
materials, pet hair, etc. it is very important  
that the control compartments, burners  
and circulating air passageways of the  
appliance are kept clean.  
4. Always turn off gas to the pilot (millivolt  
appliances) and let the appliance cool down  
before cleaning. Before re-lighting, refer  
to the lighting instructions in this manual.  
Lighting instructions may also be found  
on the pull out lighting instruction labels  
attached to the gas control valve.  
5. Always keep the appliance area clear and  
free from combustible materials, gasoline  
and other flammable liquids.  
6. Remember,Millivoltapplianceshaveacontinu-  
ousburningpilotame. Exercisecautionwhen  
using products with combustible vapors.  
clean Logs and Burner  
Carefully remove the logs (use care when han-  
dlingtheberlogs,astheybecomequitefragile  
after curing). Vacuum out any foreign matter  
(lint, carbon, etc). on the burner. Ensure the  
burner ports are “open.” Remove any carbon  
deposits from the under side of the logs using  
a vacuum cleaner, or a soft bristled brush (i.e.  
paint brush). Note: Improper positioning of  
logs can create carbon build-up and will alter  
the performance of the appliance.replacing  
Logs -  
clean Lower control compartment  
Keep lower control compartment clean by  
vacuuming or brushing it out at least twice a  
year (also clean the air venturi with a brush or  
wire). More frequent cleaning may be required  
due to accumulation of lint from carpeting,  
bedding materials, pet hair, spider webs, etc. it  
is very important that control compartments,  
burners, circulating air passageways and air  
venturi on the appliance are not obstructed  
in any way.  
If the logs become damaged by accident or im-  
proper handling and need replacement, use only  
the proper replacement logs from manufacturer  
(see Pages 26 & 27 for ordering information).  
re-install embers, Logs and Vermiculite  
- Carefully follow placement instructions on  
Pages 7 to 9 ). All logs should fit onto cor-  
responding pins and/or log stoppers. This will  
ensure a proper flame and safe combustion.  
cleaning Glass  
(seeFrontGlassEnclosurePanel, Removaland  
Installation on Page 6 )  
inspect Wiring  
Refer to wiring diagrams on Page 12.  
Maintenance  
Note: Cleanglassafterrsttwoweeksofopera-  
tion (after Burn-In period is over) and then only  
when necessary and when the fireplace is cool.  
Wipe surface with clean, dampened, soft cloth.  
Followwithdry, softtowelasdesired. Takecare  
not to scratch the glass surface.  
(see Maintenance schedule, Page 22)  
Refertothemaintenancescheduleformaintenance  
tasks, procedures, periodicity and by whom they  
shouldbeperformed. Alwaysverifyproperopera-  
tion of the appliance after servicing.  
WarninG  
Label all wires prior to discon-  
nection when servicing con-  
trols. Wiring errors can cause  
improper and dangerous opera-  
tion. Verify proper operation  
after servicing.  
The viewing glass should be cleaned periodi-  
cally to remove any build-up caused from the  
following:  
WarninG  
turnoffgasandelectricalpower  
before servicing the appliance.  
iMportant  
do not use abrasive cleaners  
on glass. never clean the glass  
when it is hot.  
Inspect and clean all wire connections. Ensure  
that there is no melting or damage. Inspection  
should include:  
caution  
Wearglovesandsafety Glasses  
for protection while doing  
required maintenance.  
• Terminals at the Valve  
• OFF/ON Switch  
• (Optional Control Switch) Wall Thermostat,  
Remote Control or Remote Wall Switch Kit  
• During start-up, it is normal for condensa-  
tion to form on the inside of the glass (this  
condensation and fog will usually disappear  
in a few minutes). The moisture can cause  
lint, dustandotherairborneparticlestocling  
to the glass surface.  
• Initial curing of the high temperature paint  
and burning off of lubricants used in the  
manufacturing process may result in a film  
on the glass.  
• A white coating may form on the glass as a  
result of impurities and minerals in the fuel.  
It is recommended that the glass be cleaned  
two or three times during each heating season,  
depending on the circumstances present. The  
following cleaning solutions are approved for use  
to clean glass:  
• Non-ammonia based household cleaner  
• 50%-50% mix of white vinegar & water  
• Gas fireplace/stove glass cleaner  
inspect Burner Flame appearance  
iMportant  
always verify proper operation  
after servicing.  
Ensure that the burner flame appearance  
resembles the flame shown in Figures 10 &  
11 and as described in Flame Appearance and  
Sooting on Page 10. The Homeowner must  
contact a qualified service technician at once  
if any abnormal condition is observed.  
Before re-lighting the replace, refer to the  
lighting instructions in this manual. instruc-  
tions are also found on pull-out panels  
located below the glass door in the control  
compartment.  
small area paint touch-up  
The finish of the appliance is a high-qual-  
ity powdercoat. Only use factory supplied  
powdercoat paint kit for touch-ups. Paint is  
availableatyourlocalauthorizedLennoxHearth  
Products dealer, cat. no. 90L74. Never attempt  
to paint a hot fireplace.  
inspect Venting system  
The appliance and venting system should be  
thoroughly inspected before initial use and  
at least annually by a qualified service techni-  
cian (inspection should include ensuring that  
exhaust or intake passages are unobstructed  
and vent components are properly assembled  
and not damaged).  
Do not attempt to repaint the appliance until the  
finish is completely cured (see Burn-In Period  
onPage3).Ifthesurfacelaterbecomesstained  
ormarred, itmaybelightlysandedandtouched  
up with spray paint.  
inspect Glass Gasket - Visually inspect the  
gasket on the backside of the glass enclosure  
panels. The gasket surface must be clean, free  
of irregularities and seated firmly.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
These are direct-vent appliances. They are  
designed to operate only when the front glass  
enclosure panel is installed. Generally the front  
glass enclosure panel should not be removed  
except to gain access to the components within  
the firebox, and the appliance may only be op-  
erated without the front glass enclosure panel  
in place for very brief periods of time during  
appliance checkout and adjustment. Note: The  
flame appearance will be diminished while the  
front glass enclosure panel is removed.  
removing Glass enclosure panels  
(see Figure 6)  
Front Glass enclosure panel, removal  
and installation  
1. Remove the top louver assembly by pulling  
it up and out.  
WarninG  
donotoperateappliancewiththe  
glass front removed, cracked or  
broken. replacementoftheglass  
should be done by a licensed or  
qualied service technician.  
2. Remove the control compartment access  
door (see removal instructions on Page 3  
- Removing Control Compartment Door).  
3. Locate the two (2) latches at the top of the  
controlcompartment. Todisengagethetwo  
latches from the bottom vee-flange of the  
glassenclosurepanel,reachforthehandles  
located towards the back of the latches and  
pull the handles down toward the front of  
the appliance.  
During this appliance checkout and adjust-  
ment period, a potential safety hazard exists  
- eXercise eXtreMe caution to prevent  
the occurrence of any burn injuries from the  
exposedamesorhotsurfaces. Alsonote,that  
while the front glass enclosure panel (or any of  
the panels) is removed, the flame appearance  
will appear to be smaller than normal.  
WarninG  
do not attempt to substitute the  
materials used on this door, or  
replace cracked or broken glass  
with any materials other than  
those provided by the appliance  
manufacturer.  
4. Swing the bottom of the door out and raise  
it slightly to lift the top flange of the door  
frame away from the appliance.  
installing Glass enclosure panels  
(see Figure 6)  
top Flange on  
Glass door  
WarninG  
1. Visually inspect the gasket on the backside  
of the glass panel. The gasket surface must  
be clean, free of irregularities and seated  
firmly.  
Handle this glass with extreme  
care! temperedglassissuscep-  
tible to damage do not scratch  
or handle roughly while rein-  
stalling the glass door frame.  
Glass door  
2.Positiontheglassenclosurepanelinfrontof  
thereboxopeningata45degreeangleand  
engage the top flange over the lip at the top  
of the firebox opening. See Figure 6.  
WarninG  
do not attempt to touch the front  
enclosure glass with your hands  
while the replace is in use.  
3. Swing the glass enclosure panel down and  
back. Ensure the gasket seats evenly as the  
panel draws shut. Engage the Vee-flange at  
the bottom of the panel with the latches and  
close the latches to secure the panel.  
WarninG  
Bottom Vee-flange  
Glass door  
4. Reinstall the control compartment door  
see installation instructions on Page 3,  
Reinstalling Control Compartment Door).  
Firebox Floor  
the glass door of this appli-  
ance must only be replaced as a  
complete unit as provided by the  
manufacturer. do not attempt to  
replacebroken,crackedorchipped  
glass separately.  
Glass door Latch  
Figure 6 - instaLLinG GLass door  
note: diaGraMs & iLLustrations are not to scaLe.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Placetherearlog(A)asshown. Positionthe  
2 notches on the bottom of the log over the  
2 corresponding locating brackets against  
the back wall of firebox.  
2. Place the left log (B) as shown. The notch  
on the bottom of the log should fit over the  
corresponding locating bracket.  
3. Place the right log (E) as shown. The hole  
on the back of the log should fit over the  
corresponding pin on the rear log (A). Make  
sure that the log is positioned so it aligns  
to the sides of the gas ports on the corner  
of the burner.  
4. Place the left center log (C) as shown.  
The forked end of the log fits into the cor-  
responding notch on rear log (A). The slot  
on the other end (bottom) of log fits over  
the corresponding locating bracket on the  
sub-floor.  
instaLL VerMicuLite, VoLcanic  
stone, GLoWinG eMBers and LoGs  
WarninG  
the size and position of the log  
set was engineered to give the  
appliance a safe, reliable and  
attractive ame pattern. any  
attempt to use a different log  
set in the replace will void  
the warranty and will result in  
incomplete combustion, soot-  
ing, and poor ame quality.  
1. Remove the front glass enclosure panel  
(see Removing Glass Enclosure Panels on  
this page).  
2. Carefully remove the old logs, embers  
volcanic stone and vermiculite from the  
firebox. Handle logs carefully to prevent  
breakage.  
3. InstallVermiculite-Place some vermiculite  
on the firebox floor around the burner (the  
entire bag of vermiculite will NOT be used).  
See Figures 8 & 9. do not pLace anY  
VerMicuLite on tHe Burner. Mound  
up a portion of the vermiculite in front of the  
burner.  
WarninG  
this appliance is not designed  
to burn wood. any attempt to  
do so could cause irreparable  
damage to appliance and prove  
hazardous to your safety.  
5. Place the right center log (D) as shown. One  
end of the log fits into the corresponding  
indent on the right log (E). The slot on  
the other end (bottom) of log fits over the  
corresponding locating bracket on the sub-  
floor.  
4. install decorative volcanic stone - Sprinkle  
the decorativevolcanicstone(darkcolored)  
on top of the vermiculite (light colored) in a  
pleasing pattern (see Figures 8 & 9).  
5. Placement of Glowing Embers -  
LMDV-4035 - Install as Follows  
Separatethe Embers(rockwool)intopieces  
about the size of a quarter (see Figure 7).  
Keep the pieces fluffed up, not matted.  
Distribute these pieces over the surface of  
the burner, as shown in Figures 8 & 9. Do  
not use more than is necessary. Ensure that  
the main burner slots remain uncovered by  
the ember material.  
WarninG  
Carefullypositiontheceramicberlogsandtwigs  
over the burner as shown in Figure 9. Logs  
should be placed in the order shown and per the  
following instructions.  
iflogsarenotinstalledaccording  
to the log installation instruc-  
tions, flame impingement and  
improper combustion could  
occur and result in soot and/or  
excessive production of carbon  
monoxide (co), a colorless,  
odorless, toxic gas.  
1. Position the center log (C) onto the 2 cor-  
responding location pins on the burner.  
2. Placetherearlog(A)asshown. Positionthe  
2 notches on the bottom of the log over the  
2 corresponding locating brackets against  
the back wall of firebox.  
3. Place the left log (B) as shown. The notch  
on the bottom of the log should fit over the  
corresponding locating bracket.  
Note: This appliance is provided with enough  
Glowing Embers for several applications, do  
not use all that is in a new bag at one time. For  
bestglowingeffect,replacetheembermaterial  
annually.  
Glowing Embers  
6. placement of Logs and twigs -  
Separate into Quarter  
Size (separate) Pieces  
All logs that have locating notches or slots to  
help ensure that they are properly positioned.  
All top logs that rest on lower logs, do so  
over notches, indents or pins. Proper twig  
placementiscriticaltopreventsooting. Twigs  
shouldbeplacedinthegapsbetweentheame  
peaksandshouldbepositionedsotheydonot  
impinge the flames.  
4. Place the right log (E) as shown. The notch  
on the bottom of the log should fit over the  
corresponding locating bracket. Make sure  
that the log is positioned so it aligns to the  
sides of the gas ports on the corner of the  
burner.  
5. Place the center front log (D) as shown.  
The slot in the bottom of the log fits over  
the corresponding location bracket on the  
sub-floor.  
Bag of Glowing  
Embers (rockwool)  
Figure 7  
LMDV-3328 & LMDV-3530 - Install as Follows  
Carefullypositiontheceramicberlogsandtwigs  
over the burner as shown in Figure 8. Logs  
should be placed in the order shown and per the  
following instructions.  
WarninG  
reFerence  
Firebox accessories/parts  
donotattempttoinstallthelogs  
until the appliance installation  
hasbeencompleted,thegasline  
connected and tested for leaks  
and the initial burner operation  
has been checked out.  
cat. no.  
Modelno.  
description  
88L53  
FGe  
Bag of Glowing embers  
(1 oz. rockwool)  
Vermiculite, Bag (2 liters)  
H3696  
80L42  
Bag of decorative  
Volcanic stone  
FdVs  
Table 8  
note: diaGraMs & iLLustrations are not to scaLe.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ModeL LMdV-3328 & LMdV-3530  
Log placement instructions  
a
LoG set  
catalog number H3366  
* item  
description  
a
B
c
d
e
Log, rear  
Log, Left  
Log, Left center  
Log, right center  
Log, right  
d
* Item "letters" above correspond to photos  
B
c
e
install the embers, Vermiculite, Volcanic stone and Logs in the order  
shown here (1 through 6) and per the instructions on Page 7.  
DO NOT PLACE EMBERS OVER GAS SLOTS  
1
4
Embers  
Hole on bot-  
tom of log (E)  
fits over pin  
on log (A).  
a
Volcanic  
Stone  
V-Shapeareaoflog(E)should  
aligntosidesofburnerports  
Vermiculite  
e
The2notcheson log bottom rest on locating brackets  
2
5
a
Log(C)tsinto  
indentinLog(A)  
a
Notch  
Notch  
c
SlotonbottomofLog  
(C)tsoverbracket  
3
6
Log (D) fits  
into indent  
on Log (E)  
Slot fits over bracket.  
B
e
d
SlotonbottomofLog  
(D)tsoverbracket  
Figure 8  
note: diaGraMs & iLLustrations are not to scaLe.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ModeL LMdV-4035  
Log placement instructions  
LoG set  
catalog number H3365  
a
* item  
description  
a
B
c
d
e
Log, rear  
Log, Left  
Log, center  
Log, center Front  
Log, right  
c
B
e
* Item "letters" above correspond to photos  
d
install the embers, Vermiculite, Volcanic stone and Logs in  
the order shown here (1 through 6) and per the instructions  
on Page 7.  
1
DONOT PLACE EMBERS OVER GAS SLOTS  
Embers  
4
5
6
Volcanic  
Stone  
Vermiculite  
B
Notch on log bottom  
fits over bracket  
Place log overpins  
2
c
Pin  
Pin  
e
3
The 2 notches  
on log bottom  
rest on locating  
brackets  
Notch on log bottom  
fits over bracket  
a
Notch  
Notch  
d
Slotonbottomof Log  
(D)tsoverbracket  
Figure 9  
note: diaGraMs & iLLustrations are not to scaLe.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Burner adJustMents  
(QuaLiFied tecHnicians onLY)  
Flame appearance and sooting  
Proper flame appearance is a flame which is  
blueatthebaseandbecomesyellowish-orange  
in the body of the flame. When the appliance  
is first lit, the entire flame may be blue and will  
graduallyturnyellowish-orangeduringtherst  
15 minutes of operation. If after a short period  
the flame stays lowered blue, or if the flame is  
orange with evidence of sooting (black tip), the  
air shutter opening may need to be adjusted.  
Iftheairshutteropeningsclosedtoofar,sooting  
maydevelop.Sootingisindicatedbyblackpuffs  
developingatthetipsofverylongorangeames.  
Sootingresultsinblackdepositsformingonthe  
logs, appliance inside surfaces and on exterior  
surfacesadjacenttotheventtermination. Soot-  
ing is caused by incomplete combustion in the  
flames and lack of combustion air entering the  
air shutter opening. To achieve a warm yellow-  
ish-orangeamewithanorangebodythatdoes  
not soot, the shutter opening must be adjusted  
between these two extremes.  
Figure 10 - Burner Flame appearance Model LMdV-3328 & LMdV-3530  
air shutter adjustment Guidelines  
• If there is smoke or soot present, first check  
the log set positioning to ensure that the  
flames are not impinging on any of the logs.  
If the log set is properly positioned and a  
sooting condition still exists, then the air  
shutter opening should be increased.  
• Themoreoffsetsintheventsystem,thelarger  
the air shutter opening will need to be.  
• An appliance operated with the air shutter  
opened too far, may have flames that appear  
blue and transparent. These weak, blue and  
transparent flames are termed anemic.  
Figure 11 - Burner Flame appearance Model LMdV-4035  
Burner air shutter adjustment procedure  
5. When satisfied that the burner flame ap-  
pearance is normal, close the lower control  
compartment door.  
• Propane models may exhibit flames which  
candle or appear stringy. If this is present  
and persists, adjust the air shutter to a more  
openposition, thenoperatetheappliancefor  
a few more minutesto ensure that the flame  
normalizes and the flames do not appear  
sooty.  
1. Locateadjustmentrodandadjustairshutter  
to the standard setting as shown in Figure  
12 (adjustment rod is located in the lower  
control compartment). Note: Rotating the  
adjustment rod clockwise decreases air and  
counterclockwise increases air.  
2. Lightappliance(followlightingprocedureon  
lighting label in control compartment or see  
homeowners manual).  
3. Allowtheburnertooperateforatleast15min-  
utes while observing the flame continuously  
to ensure that the proper flame appearance  
has been achieved (see Figure 10 or 11). If  
the following conditions are present, adjust  
accordingly.  
WarninG  
air shutter adjustment should  
only be performed by a qualied  
professional service technician.  
The following chart is provided to aid you in  
achieving the correct air shutter adjustment  
for your installation.  
WarninG  
air shutter adjustment Guidelines:  
ensurefrontglasspanelisinplace  
and sealed during adjustment.  
amount of  
Flame  
air shutter  
• If flame appears weak or sooty, adjust  
theairshutter,incrementally,toamore  
open position until the proper flame  
appearance is achieved.  
primary air  
color  
adjustment  
if air shutter is  
closed too far  
Flame will air shutter  
be orange gap should be  
increased  
caution  
• If flame stays lowered blue, adjust the  
air shutter, incrementally, to a more  
closed position until the proper flame  
appearance is achieved.  
the air shutter door and nearby  
appliancesurfacesarehot. exer-  
cise caution to avoid injury while  
adjusting flame appearance.  
if air shutter is  
open too far  
Flame will air shutter  
be blue gap should be  
decreased  
4. Leave the control knob (off/pilot/on) in the  
ON position and the burner OFF/ON switch  
OFF (& remote switches, if applicable).  
note: diaGraMs & iLLustrations are not toscaLe.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
electronic appliance checkout  
sit MiLLiVoLt piLot asseMBLY  
caution  
proper pilot Flame appearance  
To light the burner, refer to the lighting instruc-  
tions on Pages 20 & 21. Ensure the igniter  
lights the pilot. The pilot flame should engulf  
the flame sensor as shown in Figure 15.  
igniter rod  
Hood  
carbonwillbeproducediftheair  
shutter is closed too much. any  
damageduetocarboningresult-  
ing from improperly setting the  
air shutter is not covered under  
the warranty.  
thermocouple  
3/8" Min.  
(9 mm)  
eLectronic piLot asseMBLY  
proper pilot Flame appearance  
3/8" to 1/2"  
proper Flame  
Burner air shutter adjustment  
(9 -13 mm)  
pilot  
adjustment  
nozzels  
adjustment set-screw  
pilot  
nozzels  
thermopile  
Figure 13  
adjustment rod up  
(Fully open position)  
Ground  
electrode  
Burner tube  
HoneYWeLL MiLLiVoLt piLot asseMBLY  
proper pilot Flame appearance  
thermocouple  
Flame rod  
air shutter  
Hot surface  
igniter  
igniter rod  
Hood  
1/8" Min.  
(3 mm)  
adjustment rod down  
Figure 15  
(minimum air opening  
ref. air shutter patent:  
u.s. pat. 5,553,603  
position)  
3/8" Min.  
Withpropercareandmaintenance, yourappli-  
ance will provide many years of enjoyment. If  
youshouldexperienceanyproblem, firstrefer  
to the troubleshooting guide in this manual.  
If problem persists, contact your Lennox  
distributor.  
Main Burner Factory air shutter  
opening setting - inches (millimeter)  
(9 mm)  
pilot  
Model  
natural  
Gas  
propane  
Gas  
nozzels  
thermopile  
1/16"  
1/4"  
LMdVt-3328  
LMdVr-3328  
LMdV-3530  
LMdV-4035  
Figure 14  
(1.58 mm)  
(6.35 mm)  
Normally, all parts should be ordered through  
your Lennox distributor or dealer. Parts will be  
shipped at prevailing prices at time of order.  
1/16"  
1/4"  
(1.58 mm)  
(6.35 mm)  
WarrantY  
Your gas appliance is covered by a limited  
twenty year warranty. You will find a copy  
of the warranty accompanying this manual.  
Please read the warranty to be familiar with  
its coverage.  
1/16"  
5/16"  
(1.58 mm)  
(7.94 mm)  
When ordering repair parts, always give the  
following information:  
1. The model number of the appliance.  
2. The serial number of the appliance.  
3. The part number.  
4. The description of the part.  
5. The quantity required.  
6. The installation date of the appliance.  
Ifyouencounteranyproblemsorhaveanyques-  
tions concerning the installation or application  
of this system, please contact your distributor,  
or Lennox directly:  
1/8"  
3/8"  
(3.18mm)  
(9.53 mm)  
Figure 12  
Retain this manual. File it with your other  
documents for future reference.  
Millivolt appliance checkout  
product reFerence inForMation  
Werecommendthatyourecordthefollowingim-  
portantinformationaboutyourreplace. Please  
contact your Lennox dealer for any questions  
or concerns. For the number of your nearest  
Lennox dealer, please call 1-800-9-LENNOX  
The pilot flame should be steady, not lifting  
or floating. Flame should be blue in color with  
traces of orange at the outer edge.  
The top 3/8" (10 mm) at the pilot generator  
(thermopile) and the top 1/8" minimum (tip)  
of the quick drop out thermocouple should be  
engulfed in the pilot flame. The flame should  
project 1" (25 mm) beyond the hood at all three  
ports. See Figures 13 or 14.  
LennoX HeartH products  
1110 West taft avenue  
orange, ca 92865  
repLaceMent parts  
A complete parts list is found at the end of  
this manual. Use only parts supplied from the  
manufacturer.  
visit us at www.Lennox.com  
To light the burner, refer to the lighting instruc-  
tions on Pages 18 & 19.  
Your Fireplace's Model Number________________________________________  
Your Fireplace's Serial Number ________________________________________  
The Date On Which Your Fireplace Was Installed___________________________  
The Type of Gas Your Fireplace Uses ____________________________________  
Your Dealer's Name ________________________________________________  
note: diaGraMs & iLLustrations are not to scaLe.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WirinG diaGraMs  
Plug blower  
into this  
receptacle  
Wiring diagrams are provided here for refer-  
ence purposes only. This information is also  
providedonschematicsattacheddirectlytothe  
appliance on a pullout panel located within the  
control compartment.  
Green  
White  
Black  
Ground - Green  
Neutral - White  
120 VAC - Black  
Junction Box  
Blower  
* Wall-mounted  
Ground  
ON/ OFF Blower  
Switch or Variable  
Speed Control Switch.  
Tab  
Broken  
caution  
Tab Intact  
Red  
Label all wires prior to discon-  
nection when servicing con-  
trols. Wiring errors can cause  
improper and dangerous appli-  
ance operation.  
J-BOX WIRING FOR  
WALL SWITCH  
BLOWER CONTROL  
Green  
Ground  
Screw  
Neutral  
Hot  
Side of  
Side of  
Receptacle  
Receptacle  
View A  
J-Box Wiring when  
using unit mounted  
relay module.  
Relay Module C/W FBK-250 only. Plug blower  
into J-Box receptacle for FBK-100 or FBK-200  
application. See View A for J-Box wiring.  
BK  
Millivolt Wiring diagram  
W
G
Optional Blower  
schematic representation only  
Junction Box  
*OFF/ON Switch  
(Integral with  
Gas Valve)  
if any of the original wire as supplied must  
be replaced, it must be replaced with type  
aWM 105o c - 18 gage wire.  
Pilot Burner  
Assembly  
Honeywell  
Electronic  
Gas  
Valve  
Igniter  
*
Leave the OFF/ON switch, which is  
Connector  
integral with the gas valve, in the ON  
position.  
GROUND  
Transformer  
**Optional Control Switches: Wall  
Switch, Wall Thermostat or Remote  
Control Receiver.  
BL  
BL  
thermopile  
*optional switch  
Field Wired  
BL  
BK  
R
24 V  
120 VAC  
Primary  
Secondary  
Notes:  
BK  
1. If any of the original wire as supplied  
must be replaced, use Type AWM 105°C  
- 18 gage wire ONLY.  
2. 120 VAC, 60 Hz - Less than 3 Amps.  
Caution: label all wires prior to  
disconnection when servicing controls.  
Wiring errors can cause improper and  
dangerous operation.  
BK = BLACK BL = BLUE  
BK  
Optional Control Switch  
Factory  
Wired  
R = RED  
G = GREEN  
W = WHITE  
W
Field Wired  
standardoFF/onswitch  
Factory  
Wired  
*optionalKitsinstalled-oFF/onwallswitch,  
wall thermostat or remote control receiver.  
note: turn the appliance-mounted oFF/on  
burner control switch to the oFF position if  
any of these kits are installed.  
schematic representation only  
electronic Wiring diagram (Honeywell) showing Blower Wiring for optional FBK-100, FBK-200 & FBK-250 Kits  
Figure 17  
Figure 16  
note: diaGraMs & iLLustrations are not to scaLe.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
accessorY coMponents  
product reference information  
Cat.  
No.  
Model  
Ship.  
Weight  
Ship.  
Volumn  
H3313 LMdVt-3328cnM  
H3314 LMdVt-3328cpM  
H3315 LMdVr-3328cnM  
H3316 LMdVr-3328cpM  
H3317 LMdVt-3328cne  
H3318 LMdVr-3328cne  
H3319 LMdV-3530cnM  
H3320 LMdV-3530cpM  
H3321 LMdV-3530cne  
H3322 LMdV-4035cnM  
H3323 LMdV-4035cpM  
H3324 LMdV-4035cne  
95 lb.  
95 lb.  
95 lb.  
95 lb.  
95 lb.  
95 lb.  
13.08 cu. ft.  
13.08 cu. ft.  
13.08 cu. ft.  
13.08 cu. ft.  
13.08 cu. ft.  
13.08 cu. ft.  
113 lb. 15.75 cu. ft.  
113 lb. 15.75 cu. ft.  
113 lb. 15.75 cu. ft.  
147 lb. 20.18 cu. ft.  
147 lb. 20.18 cu. ft.  
147 lb. 20.18 cu. ft.  
standard remote control system  
deluxe remote control system  
The Model RCL (Standard) Remote Control System,  
features a simplistic OFF/ON control function for the  
fireplace. Thismodelincludesahand-heldtransmitter,  
a remote receiver with wall-mount cover plate and  
all hardware required to install the unit. The remote  
receiver can be wall or hearth mounted.  
The Model RCL-T (Deluxe) Remote Control System  
has all of the features of the standard system along  
withanaddedeasytoreadLCDscreenwhichpresents  
access to many enhancements, including; battery  
power level indicator, timer, mode of operation,  
thermostatic display including room temperature in  
either metric of English units, flame indicator and  
clock. Fully programmable, the Model RCL-T allows  
for virtual command over nearly all operational and  
temperature variables, using the hand held remote  
control transmitter.  
The transmitter has ON and OFF functions that are  
activated by pressing either button on the face of  
the transmitter. When a button on the transmitter  
is pressed, a signal light illuminates briefly to verify  
that a signal has been sent.  
The Model RCL is designed to operate with all mil-  
livolt ignition systems, as well as electronic ignition  
systems. It may be installed with use for either  
natural gas or propane gas appliances. The RCL  
offers ease of installation and allows you to execute  
on-off commands to the fireplace effortlessly with  
one simple motion.  
The Model RCL-T (Deluxe) remote control system  
is installed in the same manner as the standard  
system, may be operated with electronic and mil-  
livolt systems with either natural gas or propane gas.  
The RCL-T comes complete with detailed operating  
instructions.  
digital Wall thermostat  
TheModelRCLcomescompletewithdetailedoperat-  
ing instructions.  
The wall thermostat kit provides temperature control  
for optimum comfort.  
remote control Kit, standard  
remote control Kit, deluxe  
Wall thermostat, Millivolt  
cat. no.  
Model no.  
description  
cat. no.  
Model no.  
description  
cat. no.  
Model no.  
description  
H0249  
rcL  
remote control system  
(standard)  
H0251  
rcL-stat  
remote control system  
(deluxe)  
H4635  
dWtK  
Wall thermostat Kit,  
White  
(ref. Form # 750,127M)  
(ref. Form # 750,129M)  
Arch Door Kit - Polished Brass  
cat. no.  
Model  
Fireplace Model  
LMdVt-3328,  
LMdVr-3328  
98L05  
adK33cpB  
26M43  
81L35  
adK35cMpB  
adK40cpB  
LMdV-3530  
LMdV-4035  
unit-Mountable rocker switch  
This rocker switch kit can be installed directly in  
the gas valve mounting bracket (millivolt gas valve  
equipped fireplaces) to provide On/Off operation in  
lieu of a wall switch.  
Arch Door Kit - Brushed Stainless Steel  
cat. no.  
Model  
Fireplace Model  
LMdVt-3328,  
LMdVr-3328  
98L62  
adK33cBs  
arch door Kits  
rocker switch Kit  
The arch door kits are easy to install and do not re-  
quire hardware to attach them to the standard door  
frame. The decorative arch kits can not be used in  
conjunction with the screen panel kit.  
26M44  
98L69  
adK35cMBs  
adK40cBs  
LMdV-3530  
LMdV-4035  
cat. no.  
Model no.  
description  
80L41  
Frs  
rocker switch Kit  
(ref. Form # 750,021M)  
(ref. Form # 750,037M)  
note: diaGraMs & iLLustrations are not to scaLe.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
accessorY coMponents  
style View™ doors - arch design Kits  
cat. no.  
Model  
Model  
Model  
series  
Arch Design  
H0858  
H0859  
H0860  
H0861  
H0862  
H0863  
H0864  
H0865  
ad35c  
ad35ti  
ad35sp  
ad35aB  
ad40c  
35” arch doors, charcoal  
35” arch doors, textured iron  
35” arch doors, satin pewter  
35” arch doors, antique Brass  
40” arch doors, charcoal  
LMdV-3530  
LMdV-4035  
ad40ti  
ad40sp  
ad40aB  
40” arch doors, textured iron  
40” arch doors, satin pewter  
40” arch doors, antique Brass  
style View doors - arch pane design Kits  
H0930  
H0931  
H0932  
H0933  
H0934  
H0935  
H0936  
H0937  
apd35c  
35” arch pane doors, charcoal  
Arch Pane Design  
Barrier screen panel Kit  
apd35ti  
apd35sp  
apd35aB  
apd40c  
35” arch pane doors, textured iron  
35” arch pane doors, satin pewter  
35” arch pane doors, antique Brass  
40” arch pane doors, charcoal  
This easy to install optional screen panel installs over  
thestandardglassenclosurepanelandprovidesabar-  
riertopreventdirectcontactwiththehotglasssurface.  
These screen panels cannot be used in conjunction  
with the arch door kits or door frame kits.  
LMdV-3530  
LMdV-4035  
apd40ti  
apd40sp  
apd40aB  
40” arch pane doors, textured iron  
40” arch pane doors, satin pewter  
40” arch pane doors, antique Brass  
screen panel Kits  
cat. no.  
Model no.  
Models Where used  
LMdVt-3328  
LMdVr-3328  
98L04  
HG33  
style View doors - square design Kits  
H0946  
H0947  
H0948  
H0949  
H0950  
H0951  
H0952  
H0953  
sd35c  
35” sq. doors, charcoal  
26M48  
26M49  
HG35M  
HG40M  
LMdV-3530  
LMdV-4035  
Square Design  
sd35ti  
sd35sp  
sd35aB  
sd40c  
35” sq. doors, textured iron  
35” sq. doors, satin pewter  
35” sq. doors, antique Brass  
40” sq. doors, charcoal  
LMdV-3530  
LMdV-4035  
(ref. Form # 750,101M)  
sd40ti  
sd40sp  
sd40aB  
40” sq. doors, textured iron  
40” sq. doors, satin pewter  
40” sq. doors, antique Brass  
style View doors - square pane design Kits  
H0962  
H0963  
H0964  
H0965  
H0966  
H0967  
H0968  
H0969  
spd35c  
spd35ti  
spd35sp  
spd35aB  
spd40c  
35” sq. pane doors, charcoal  
Square Pane Design  
35” sq. pane doors, textured iron  
35” sq. pane doors, satin pewter  
35” sq. pane doors, antique Brass  
40” sq. pane doors, charcoal  
LMdV-3530  
LMdV-4035  
spd40ti  
spd40sp  
spd40aB  
40” sq. pane doors, textured iron  
40” sq. pane doors, satin pewter  
40” sq. pane doors, antique Brass  
decorative arch screen panel Kit  
This easy to install optional screen panel installs over  
thestandardglassenclosurepanelandprovidesabar-  
riertopreventdirectcontactwiththehotglasssurface.  
These screen panels cannot be used in conjunction  
with the arch door kits or door frame kits.  
(ref. Form # 775,169M)  
style View screen doors -  
These Style View screen doors come in 4 beautiful styles. The Style View door installs over the standard glass  
enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. The door includes  
heavy duty magnet door latches and functional twin-pane screen doors.  
decorative arch screen panel Kit  
cat. no.  
H3592  
H3593  
H3594  
Model  
Model  
Model series  
LMdVt-3328 & LMdVr-3328  
LMdV-3530  
daspK33ti 33” decorative arch screen panel  
daspK35ti 35” decorative arch screen panel  
daspK40ti 40” decorative arch screen panel  
LMdV-4035  
(ref. Form # 750,199M)  
note: diaGraMs & iLLustrations are not to scaLe.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
accessorY coMponents  
Forced air Blower Kits  
WhiteWallswitchKit  
cat.  
no.  
Modelno.  
FBK-100  
FBK-200  
FBK-250  
description  
cat.no.  
Modelno.  
FWsK  
description  
85L87  
oFF/onWallswitchKit  
80L84  
80L85  
80L86  
Blower, standard  
(single speed)  
4 piece trim Kit  
cat.no. Modelno. description  
Blower, Variable speed  
(w/wall-mounted switch)  
oFF/on Wall switch Kit  
The OFF/ON wall switch kit may be used to control  
the operation of the fireplace burner. Install the  
OFF/ON wall switch in a convenient location near  
the fireplace.  
Blower, Variable speed  
(w/unit-mounted switch)  
35” 4 piece Finish trim Kit,  
96K17  
96K18  
tK35pB4  
tK40pB4  
polished Brass, LMdV-3530  
94L89  
94L90  
FBK-100-36  
FBK-200-36  
Blower, standard, 36 pack  
40” 4 piece Finish trim Kit,  
polished Brass, LMdV-4035  
Blower Kit - Variable speed  
with Wall switch 36 pack  
(ref. Form # ii-9299)  
H0543  
FBK-250-36  
Blower Kit - Variable speed  
with thermo snap switch  
36 pack  
polished Brass 4-piece trim Kit  
This kit contains brass trim pieces used to finish the  
gapsbetweenthewallboardandthereplace,provid-  
ing the appliance a brass perimeter highlight. This kit  
contains the trim pieces and these instructions  
(ref. Form # 750,028M & 750,029M)  
Forced air Kit  
TheFBK-100blowerprovidesconstantvelocityforced  
air circulation. The FBK-200 assembly with variable  
speed,wall-mountableswitchprovidesvariablespeed  
forced air circulation. The FBK-250 assembly with  
variable speed unit-mountable switch, also provides  
variable speed forced air circulation.  
3 piece trim Kit  
Variable speed Wall  
cat.no. Modelno.  
description  
switch  
33” polished Brass,  
LMdVt-3328, LMdVr-3328  
Provides variable speed  
control if optional blower kit  
is purchased.  
H0453 tK33pB3  
35” polished Brass,  
LMdV-3530  
96K21 tK35pB3  
96K22 tK40pB3  
H1813 tK33Bs3  
H1815 tK35Bs3  
40" polished Brass,  
LMdV-4035  
Brickaded Wall Liner Kits  
VariablespeedWall switch  
cat. no.  
Modelno.  
description  
cat. no.  
Model no.  
description  
33” Brushed stainless,  
LMdVt-3328, LMdVr-3328  
Brick Liner Kit, top Vent,  
LMdVt-3328  
045571H  
VsWs  
rocker switch Kit  
H0912  
MBLK-33t  
35” Brushed stainless,  
LMdV-3530  
Brick Liner Kit, rear Vent,  
LMdVr-3328  
H0918  
H0913  
H0914  
MBLK-33r  
MBLK-35  
MBLK-40  
Bag of Glowing embers  
40", Brushed stainless,  
LMdV-4035  
H1816  
tK40Bs3  
tK33c3  
tK35c3  
tK40c3  
Brick Liner Kit, top/rear,  
LMdV-3530  
Bag of Volcanic stone  
Replacement ember materi-  
als or volcanic stone are  
available for use with these  
appliances. Orderkitsaspart  
of the periodic maintenance  
of the appliance.  
33” charcoal,  
LMdVt-3328, LMdVr-3328  
H4820  
H4821  
H4823  
Brick Liner Kit, top/rear,  
LMdV-4035  
35” charcoal,  
LMdV-3530  
(ref. Form # 750,160M)  
40" charcoal,  
LMdV-4035  
Brickaded panel Liner Kit  
decorative Firebox accessories  
(all models)  
The brickaded liner kits include ceramic panels as  
shown here. Thepanelshavebrick-likefeatures in relief.  
(ref. Form # 750,147M)  
cat. no.  
Modelno.  
description  
polished Brass 3-piece trim Kit  
This kit contains brass trim pieces used to finish the  
gapsbetweenthewallboardandthereplace,provid-  
ing the appliance a brass perimeter highlight. This kit  
contains the trim pieces and these instructions  
Bag of Glowing embers  
(1 oz. rockwool)  
88L53  
FGe  
Bag of decorative  
Volcanic stone  
80L42  
FdVs  
(FDVS ref. Form #750,010M)  
note: diaGraMs & iLLustrations are not to scaLe.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
accessorY coMponents  
* assembled 8-piece Louver Kits  
polished Brass  
Brushed stainless  
Models  
Where used  
cat. #  
Model  
cat. #  
Model  
LMdVt-3328  
LMdVr-3328  
H1522 LK-400B  
H1523 LK-400Bs  
I
LMdV-3530  
LMdV-4035  
H1524 LK-500B  
H1525 LK-500Bs  
H1527 LK-600Bs  
H1526 LK-600B  
(ref. Form # 750,166M)  
touch-up paint Kit  
* Lennox Nameplate Logo, 12L15, is sold separately.  
Repair of minor scratches and discoloration of the  
appliance charcoal painted surfaces may be accom-  
plished with the touch-up paint kit.  
polished Brass & Brushed stainless Louvers Kits  
These kits include a top 4-louver assembly and a bottom 4-louver assembly. They provide a touch of elegance.  
These kits can be retrofitted to previously installed appliances.  
touch-up paint Kits  
(all models)  
2- piece door Frame Kits  
cat. no.  
Modelno.  
description  
Models  
Where used  
polished Brass  
Brushed stainless  
90L74  
tpK-c  
touch-up paint (charcoal)  
(TPK-C ref. Form # 504,216M)  
cat. #  
Model  
cat. #  
Model  
LMdVt-3328  
LMdVr-3328  
98L18  
2dFK33pB  
98L19  
2dFK33Bs  
26M88  
26M89  
2dFK35pB  
2dFK40pB  
26M91  
26M92  
2dFK35Bs LMdV-4035  
2dFK40Bs LMdV-4035  
(ref. Form # 750,098M)  
Termination Shroud  
polished Brass & Brushed stainless 2-piece door Frame Kits  
These kits are designed to attach directly to the front face of the appliance at the glass enclosure panel's top  
and bottom edges.  
4 piece door trim Kits  
polished Brass  
Brushed stainless  
Models  
Where used  
cat. #  
98L22  
Model  
cat. #  
Model  
Deluxe Termination  
Guard  
LMdVt-3328  
LMdVr-3328  
4dFK33pB  
98L23  
4dFK33Bs  
26M82 4dFK35pB  
26M83 4dFK40pB  
26M85  
26M86  
4dFK35Bs LMdV-3530  
4dFK40Bs LMdV-4035  
(ref. Form # 750,098M)  
door Frame Kits  
A decorative door frame kit is available for use with these appliances. It is designed to attach directly to the front face  
of the appliance at the four edges of the glass enclosure panel resulting in the appearance of a picture frame.  
Square Termination  
Guard  
eyebrow Hood Kits  
polished Brass  
Brushed stainless  
Models  
Where used  
termination Guard Kits  
(all models)  
cat. #  
Model  
cat. #  
Model  
cat. no.  
H5820  
87L02  
Modelno.  
description  
LMdVt-3328  
LMdVr-3328  
98L10  
eB33pB  
98L11  
eB33Bs  
4.5HtsK  
termination shroud  
96K67  
96K68  
eB35pB  
eB40pB  
88L49  
88L50  
eB35Bs  
eB40Bs  
LMdV-4035  
LMdV-4035  
sV4.5HGs  
termination Guard,  
deluxe  
17M52  
sV4.5HGs-1  
termination Guard,  
* these hood kits replace the standard hood that comes with  
these replaces.  
square  
Ref. 750,109M Ref. 750,055M  
(ref. Form #504,142M)  
polished Brass & Brushed stainless Hood Kits  
termination Guard Kits  
Attractive hoods are available in two styles. These hoods are designed to be fitted to the glass viewing sides  
of the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation,  
the hood reduces heat effects to decorative mantles and finish materials located above the fireplace opening.  
The hood kit replaces the standard hood that comes with these appliances and snaps into place. These kits  
can be retrofitted to previously installed appliances.  
The vent termination guards may be used to cover  
the vent termination on the exterior of the home  
to minimize exposure to the hot surface of the  
termination.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: Door & Trim Kits are for 1 side only. If set is desired, order 2 kits.  
accessorY coMponents  
Sunrise Style (upper grille shown)  
Crescent Style (lower grille shown)  
Cat. No.#  
H3565  
Model  
Description  
35” charcoal  
Model Series  
suGK35c  
suGK35sp  
suGK40c  
suGK40sp  
H3567  
35” satin pewter  
40” charcoal  
tall style View doors -  
upper GriLLe Kits  
sunrise  
These decorative screen doors are offered in four  
attractive finishes and fit on the face of the appliance  
over the glass doorframe to prevent direct contact  
withthehotglasssurface. Thescreenspreventdirect  
contactwiththehotglasssurface.Thesedoorsreplace  
the bottom louver assembly and cover the control  
compartment which elongates the appearance of the  
height of the fireplace face.  
H3573  
H3575  
40” satin pewter  
H3541  
cuGK35c  
35” charcoal  
H3543  
H3549  
H3551  
cuGK35sp  
cuGK40c  
cuGK40sp  
35” satin pewter  
40” charcoal  
upper GriLLe Kits  
crescents  
40” satin pewter  
style View tall arch pane screen door Kits  
cat#  
Model  
description  
H3569  
H3571  
H3577  
H3579  
sLGK35c  
sLGK35sp  
sLGK40c  
sLGK40sp  
35” charcoal  
H3525  
H3527  
H3529  
H3531  
tapd35c  
tapd35sp  
tapd40c  
tapd40sp  
35”, charcoal  
35”, satin pewter  
40”, charcoal  
40”, satin pewter  
35” satin pewter  
40” charcoal  
LoWer GriLLe Kits  
sunrise  
40” satin pewter  
H3545  
H3547  
H3553  
H3555  
cLGK35c  
35” charcoal  
cLGK35sp 35” satin pewter  
cLGK40c 40” charcoal  
cLGK40sp 40” satin pewter  
LoWer GriLLe Kits  
crescents  
(ref. Form # 750,202M)  
decorative Grille Kits  
These decorative grilles are offered in two attractive finishes and fit on the  
face of the appliance in place of the standard louvers.  
note: diaGraMs & iLLustrations are not to scaLe.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LiGHtinG instructions – HoneYWeLL and sit MiLLiVoLt Gas VaLVe  
For Your saFetY read BeFore LiGHtinG  
WarninG: iF You do not FoLLoW tHese instructions eXactLY, a Fire or eXpLosion  
MaY resuLt causinG propertY daMaGe, personaL inJurY or Loss oF LiFe.  
a. This appliance has a pilot which must be lighted with a piezo  
igniter. When lighting the pilot, follow these instructions  
exactly.  
do not use any phone in your building.  
immediately call your gas supplier from a neighbors  
phone.  
if your gas supplier cannot be reached, call the re depart-  
B. BeFore operatinG smell all around the appliance area for  
gas. Be sure to smell next to the floor because some gas is  
heavier than air and will settle on the floor.  
ment.  
c. Use only your hand to push in or turn the gas control knob.  
Never use tools. If the knob will not push in or turn by hand,  
do not try to repair it, call a qualified service technician. Force  
or attempted repair may result in a fire or an explosion.  
WHat to do iF You sMeLL Gas  
extinguish any open ame.  
open windows.  
do not light any appliance.  
do not touch any electrical switches.  
d. Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect the  
appliance and to replace any part of the control system and  
any gas control which has been under water.  
LiGHtinG instructions  
1. stop! Read the safety information above on this Page.  
2. Access the lower control compartment.  
3. Turn remote wall switch to “OFF.”  
6. Wait five (5) minutes to clear out any gas. If you then smell gas,  
STOP! Follow “B” in the safety information above on this Page. If  
you do not smell gas, go to the next step.  
7. Push in gas control knob slightly and turn counterclockwise  
to “PILOT.”  
HoneYWeLL  
4. Verify main line shut-off valve is open.  
MiLLiVoLt piLot  
8. Push in control knob all the way and hold in.  
5. Push in gas control knob slightly and turn clockwise  
Immediately light the pilot by triggering the  
spark igniter (pushing the button) until pilot  
lights. Continue to hold the control knob in  
for about 1 minutes after the pilot is lit.  
Release knob and it will pop back up. Pilot  
should remain lit. If it goes out, repeat steps  
5 through 8.  
to “OFF.”  
iGniter  
T
F
F
O
O
L
I
P
H
I
O
L
HoneYWeLL  
MiLLiVoLt  
Gas VaLVe  
N
If knob does not pop up when released,  
stop and immediately call your service  
O U T I N  
sit  
technician or gas supplier.  
MiLLiVoLt piLot  
I
H
sit  
MiLLiVoLt  
Gas VaLVe  
F
F
O
P
I
L
O
L
W
T
If pilot will not stay lit after several tries,  
turn the control knob to “OFF” and call  
your service technician or gas supplier.  
O
N
P
I
L
T O  
9. Turn gas control knob counterclockwise  
iGniter  
to “ON.”  
Note: Knob cannot be turned from “PILOT” to “OFF”  
unless the knob is pushed in slightly. Do not force.  
10. Close lower control compartment.  
to turn oFF Gas to appLiance  
1. Turn remote wall switch “OFF.” The pilot will remain lit for  
4. Depress gas control knob slightly and turn clockwise  
normal service.  
to “OFF.” Do not force.  
2. For complete shutdown, turn remote wall switch to “OFF.”  
5. Close lower control compartment.  
3. Access the lower control compartment.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONSÀ LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE  
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un  
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre  
exactement ces instructions.  
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune  
odeur de gaz autour de l’apareil ainsi que près du sol; certains gaz, étant  
plus lourds que l’air, descendent au niveau du sol.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR  
DE GAZ:  
Appelezimmédiatementvotrecompagniedegazenutilisantletéléphone  
du voisin.  
S’il vous est impossible de contacter votre compagnie de gaz, appelez  
le service des incendies.  
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.  
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,  
n’essayez pas de le réparer. Communiquez immédiatement avec un  
technicien de service qualifié. Toute tentative pour le forcer ou le  
réparer, risquerait de provoquer un incendie ou une explosion.  
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été  
immergé dans l’eau. Appelez immédiatement un technicien compétent  
pour faire inspecter l’appareil et remplacer toute pièce du système de  
réglage ou commande du gaz qui a été sous l’eau.  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
N’allumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez d’aucun téléphone dans votre édifice.  
INSTRUCTIONS D'ALLUMAGE  
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.  
2. Ouvrez le compartiment de contrôle du bas.  
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.  
4. Assurez-vous que la soupape d’arrêt de la canalisation principale est  
ouverte.  
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.  
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à  
étincelle (en poussant le bouton) jusqu’à ce que la veilleuse  
s’enflamme. Continuez de tenir le bouton de réglage enfoncé  
pendant environ 90 secondes après l’allumage de la veilleuse.  
Relâchez le bouton et il sortira  
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
le sens des aiguilles d’une montre  
d’arrêt “OFF”.  
jusqu’à la position  
subitement. La veilleuse devrait rester  
HONEYWELL  
allumée. Si elle s’éteint, répétez les  
MILLIVOLT PILOT  
étapes 5 à 8 inclusivement.  
Si le bouton ne sort pas  
VANNE GAZ  
MILLIVOLT  
HONEYWELL  
T
F
F
O
O
L
I
P
automatiquement après avoir été  
relâché, arrêtez immédiatement et  
téléphonez à votre technicien de  
service ou à votre fournisseur de gaz.  
H
I
O
L
N
O
PIEZO-ELECTRIQUE  
Si la veilleuse refuse de rester allumée  
I N  
O U T  
SIT  
après plusieurs tentatives, tournez le  
MILLIVOLT PILOT  
I
H
bouton de réglage jusqu’à sa position  
d’arrêt “OFF” et téléphonez à votre  
technicien de service ou à votre  
fournisseur de gaz.  
VANNE GAZ  
MILLIVOLT SIT  
F
O
F
P
I
L
O
L
O
W
T
O
N
P
I
L
O
T
9. Tournez le bouton de réglage du gaz en  
PIEZO-ELECTRIQUE  
sens inverse des aiguilles d’une  
montre  
jusqu’à sa position  
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à  
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.  
de marche “ON”.  
10. Fermez le compartiment de contrôle du bas.  
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez  
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes  
de sécurité au verso de cette plaque. Si vous ne remarquez aucune  
odeur de gaz, passez à l’étape suivante.  
11. Au besoin, rebrancher l’appareil au courant électrique et remettre  
l’interrupteur du brûleur principal à la position “ON” ou régler le  
thermostat à la température désirée.  
12. Si l’appareil ne fonctionne pas, suivre les instructions intitulées  
“Pour fermer le gaz qui alimente l’appareil” et appeler un  
technicien ou le fournisseur de gaz.  
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en  
sens inverse des aiguilles d’une montre jusqu’à la position de  
veilleuse  
“PILOT”.  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse  
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
restera allumée jusqu’au retour du service normal.  
le sens des aiguilles d’une montre  
jusqu’à la position  
d’arrêt “OFF”. Ne forcez pas le bouton.  
2. Pour une fermeture complète, tournez l’interrupteur mural à la  
position d’arrêt “OFF”.  
5. Fermez le compartiment de contrôle du bas.  
3. Ouvrez le compartiment de contrôle du bas.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LiGHtinG instructions — eLectronic  
For Your saFetY read BeFore LiGHtinG  
WarninG: iF You do not FoLLoW tHese instructions eXactLY, a Fire or eXpLosion  
MaY resuLt causinG propertY daMaGe, personaL inJurY or Loss oF LiFe.  
a. When lighting the appliance, follow these instructions  
Immediately call your gas supplier from a neighbor’s  
exactly.  
phone.  
If your gas supplier cannot be reached, call the fire  
B. BEFORE OPERATING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
department.  
c. Use only your hand to turn the gas control lever. Never  
use tools. If the lever will not turn by hand, do not try  
to repair it, call a qualified service technician. Force or  
attempted repair may result in a fire or an explosion.  
WHat to do iF You sMeLL Gas  
Extinguish any open flame.  
Open windows.  
d. Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician  
to inspect the appliance and to replace any part of the  
control system and any gas control which has been under  
water.  
Do not light any appliance.  
Do not touch any electrical switches.  
Do not use any phone in your building.  
LiGHtinG instructions  
1. stop! Read the safety information above on this Page.  
2. Turn remote wall switch to “OFF.”  
5. Turn the OFF/ON switch to “OFF”. Do not force.  
6. Wait five (5) minutes to clear out any gas. If you then  
smell gas, STOP! Follow “B” in the safety information  
above on this Page. If you do not smell gas, go to the  
next step.  
3. Open lower control compartment door.  
4. Verify main line shut-off valve is open.  
7. Turn the OFF/ON switch to “ON”. Do not force.  
Honeywell electronic Gas control Valve  
8. Turn “ON” all electrical power to appliance (remote wall  
on/oFF switch  
or appliance switch).  
9. Close lower control compartment door.  
to sHut oFF  
1. Turn off all electrical power to the appliance (remote wall  
switch).  
Front View  
to turn oFF Gas to appLiance  
1. For complete shut-down, turn remote wall switch to  
3. Turn the OFF/ON switch to “OFF”. Do not force.  
4. Close the main line shut-off valve.  
“OFF.”  
2. Open lower control compartment door.  
5. Close lower control compartment door.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU  
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
A. Lorsquevousallumezl’appareil,suivezexactementcesinstruc-  
Appelez immédiatement votre compagnie de gaz en utilisant  
le téléphone du voisin.  
tions.  
S’il vous est impossible de contacter votre compagnie de  
gaz, appelez le service des incendies.  
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez  
aucune odeur de gaz autour de l’apareil ainsi que près du sol;  
certainsgaz,étantpluslourdsquel’air,descendentauniveaudu  
sol.  
C. N’utilisez que votre main pour manipuler linterrupteur “ON/  
OFF” de la valve à gaz. N’utilisez jamais d’outils. Si  
l’interrupteur ne bouge pas manuellement, n’essayez pas de le  
réparer. Communiquez immèdiatement avec un technicien de  
service qualifié. Toute tentative pour forcer l’interrupteur ou le  
réparer, risquerait de provoquer un incendie ou une explosion.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE  
ODEUR DE GAZ  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été  
immergé dans l’eau. Appelez immédiatement un technicien  
compétent pour faire inspecter l’appareil et remplacer toute  
piècedusystèmederéglageoucommandedugazquiaétésous  
l’eau.  
N’allumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez d’aucun téléphone dans votre édifice.  
INSTRUCTIONS D’ALLUMAGE  
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous  
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B” des  
consignes de sécurité au verso de cette plaque. Si vous ne  
remarquez aucune odeur de gaz, passez à l’étape suivante.  
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette  
plaque.  
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.  
7. Tournezlamanettederéglagedugazjusqu’àlapositiondemarche  
3. Ouvrez la porte du compartiment de contrôle du bas.  
“ON”. Ne la forcez pas.  
4. Assurez-vousquelasoupaped’arrêtdelacanalisationprincipale  
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil  
est ouverte.  
(interrupteur mural).  
9. Fermez la porte du compartiment de contrôle du bas.  
5. Tournezlamanettederéglagedugazàlapositiond’arrêtOFF”.  
10. Au besoin, rebrancher l’apareil au courant électrique et  
remettre l’interrupteur principal du brûleur à la position “ON”  
ou régler le thermostat à la température désirée.  
Interrupteur  
ON/OFF  
11. Si l’appareil ne se met pas en marche, suivre les instructions  
intitulées “Pour fermer le gaz qui alimente l’appareil” et appeler  
un technicien ou le fournisseur de gaz.  
POUR ÉTEINDRE L’APPAREIL  
1. Coupeztoutlecourantélectriquequialimentel’appareil(interrupteur  
Vue de face  
mural).  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Pour une fermeture complète, tournez l’interrupteur mural à la  
3. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.  
position d’arrêt “OFF”.  
Ne la forcez pas.  
2. Ouvrez la porte du compartiment de contrôle du bas.  
4. Fermez la soupape d’arrêt de la canalisation principale.  
5. Fermez la porte du compartiment de contrôle du bas.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance scHeduLe  
annually (Before the onset of the Burning Season)  
Maintenance tasK  
accoMpLisHinG person  
procedure  
Inspecting/Cleaning Burner, Logs  
and Controls  
Qualified Service Technician  
Inspect valve and ensure it is properly operating. Check piping  
for leaks. Vacuum the control compartment, fireplace logs and  
burner area.  
Check Flame Patterns and Flame Qualified Service Technician  
Height  
Refer to Figure 10 (LMDV-3328 & LMDV-3530) or Figure 11  
(LMDV-4035)onPage10 andverifytheamepatternandheight  
displayed by the appliance conforms to the picture. Flames  
must not impinge on the logs. Ensure flames are steady (not  
lifting or floating).  
Inspecting/Cleaning Pilot and Burner  
Checking Vent System  
Qualified Service Technician  
Qualified Service Technician  
RefertoFigure13(SITMillivolt),Figure14(HoneywellMillivolt)  
or Figure 15 (Electronic) on Page 11. Remove any surface  
build-up on pilot and burner assembly. Wipe the pilot nozzles,  
igniter/flame rod and hood. Ensure the pilot flame engulfs the  
flame sensor as shown.  
Inspect the vent system at the top and at the base (within the  
firebox) for signs of blockage or obstruction. Look for any signs  
of dislocation or deterioration of the vent components. Note:  
Excessive condensation can cause corrosion of caps, pipe &  
fittings (excessive condensation can be caused by long lateral  
runs, too many elbows and/or exterior portions of the system  
being exposed to cold weather). Also inspect wall straps or  
plumbers's tape to ensure it is secure and in place.  
Appliance Checkout  
Qualified Service Technician  
Perform the appropriate appliance checkout procedure detailed  
in this manual.  
Replacing Rockwool Ember Materials Homeowner/Qualified Service  
Technician  
Remove old ember materials (rockwool) and vacuum the ember  
placement area. Place new embers as described and shown in  
Figures 8 & 9.  
periodically (After the Burning Season)  
Maintenance tasK  
accoMpLisHinG person  
procedure  
Cleaning Firebox Interior  
Homeowner  
Carefullyremovelogs,rockwool,volcanicstoneandvermiculite.  
Vacuum out interior of the firebox. Clean firebox walls and log  
grate. Replace logs, rockwool, vermiculite and volcanic stone  
as detailed in this manual.  
Check Flame Patterns and Flame Homeowner  
Height  
Refer to Figure 10 (LMDV-3328 & LMDV-3530) or 11 (LMDV-  
4035) on Page 10 and verify the flame pattern and height dis-  
played by the appliance conforms to the picture. Flames must  
not impinge on the logs.  
Checking Vent System  
Homeowner  
Inspect the vent system at the top and at the base (within the  
firebox) for signs of blockage or obstruction. Look for any signs  
of dislocation of the vent components.  
Cleaning Front Glass Enclosure Panel Homeowner  
Clean as necessary following the directions provided in this  
manual. do not toucH or atteMpt to cLean GLass  
WHiLe Hot.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
trouBLesHootinG  
Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is  
in the “ON” position.  
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.  
TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM  
sYMptoM  
possiBLe causes  
correctiVe action  
1. Spark igniter will not light pilot after  
a. Defective igniter  
Check for spark at electrode and pilot; if no spark and  
electrode wire is properly connected, replace igniter.  
repeated triggering of igniter button.  
(no spark at electrode).  
B. Defective or misaligned electrode at pilot  
Using a match, light pilot. If pilot lights, turn off pilot  
and trigger the igniter button again. If pilot lights, an  
improper gas mixture caused the bad lighting and a  
longer purge period is recommended. If pilot will not  
lightcheckgapatelectrodeandpilotshouldbe1/8"  
to have a strong spark. If gap measures 1/8", replace  
pilot (see Figures 13 or 14 on Page 11).  
WARNING: if the pilot will not light  
after 1 minute of attempting, wait  
for at least 5 minutes for gas to  
clear before attempting again.  
(spark at electrode).  
c. Gas supply pressure errant.  
Checkinletgaspressure. Itshouldbewithinthelimits  
as marked on the rating plate.  
d. Pilot orifice plugged.  
Clean or replace pilot orifice.  
2. Pilot will not stay lit after  
carefully following the lighting  
instructions.  
a. Defective pilot generator  
(thermocouple).  
Check pilot flame, it must impinge on thermocouple  
(see Figures 13 or 14 on Page 11). Clean and/or  
adjust pilot for maximum flame impingement on  
thermocouple. Ensure that the connection between  
the valve and thermocouple are tight and secure.  
3. Pilot burning, no gas to burner, Valve a. Wall switch or wires defective.  
knob “ON,” and the (standard) burner  
Check wall switch and wires for proper connections.  
Jumper wire across terminals at wall switch, if burner  
comeson,replacedefectivewallswitch.Ifokay,jumper  
wiresacrosswallswitchwiresatvalve,ifburnercomes  
on, wires are faulty or connections are bad.  
OFF/ON switch is “ON." Read impor-  
tant note below.  
B. Thermopile may not be generating suf-  
Check thermopile with millivolt meter. Take reading  
at thermopile terminals of gas valve. Should read  
325 millivolts minimum with optional wall switch  
“OFF.” Replace faulty thermopile if reading is below  
specified minimum.  
IMPORTANT NOTE: If an optional  
ficient millivolts.  
*remote switch is used for burner  
operation, if the standard burner  
OFF/ON switch is still installed on  
appliance it must be in the "OFF"  
position.  
c. Plugged burner orifice.  
Check burner orifice for blockage and remove.  
*Optional remote switch kits - wall  
switch, wall thermostat or remote  
control.  
d. OFF/ON Switch & *Remote Switch are in  
the "ON" position resulting in excessive  
resistance.  
When turning on the burner using a *remote switch,  
ensure that the standard OFF/ON switch is in the "OFF"  
position. If both switches are in the ON position, it  
may result in excessive resistance (& millivolt drain-  
age) and the burner may not come on.  
4. Frequent pilot/burner outage prob-  
a. Pilot flame may be too low or blowing (high)  
Clean and/or adjust pilot flame for maximum flame  
impingement on thermocouple (see Figures 13 or  
14 on Page 12).  
lem.  
causing the pilot/valve safety to drop out.  
TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM  
sYMptoM  
possiBLe causes  
correctiVe action  
1. Burner will not light.  
a. Faulty Valve System.  
See Below.  
B. “OFF/ON” or wall switch defective.  
Disconnect the two black wires from the wire nuts.  
Test switch(s) for continuity with a multimeter. If  
continuity is not indicated, switch(s) is defective and  
must be replaced.  
Note: Before replacing “OFF/ON” switch, Ensure to  
check wiring for loose connections or broken wires  
and repair as needed.  
2. Burners come “ON,” then turns “OFF.”  
a. Burner orifice plugged.  
Check main burner orifice(s) for blockage. Clean  
or replace.  
B. Obstructed vent system.  
Check vent system for obstructions.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
trouBLesHootinG procedure - eLectronic iGnition sYsteM  
start  
cHecK  
• Line voltage power  
• Low voltage transformer  
• Limit controller  
• thermostat  
turn off Gas supply.  
• check for proper volt-  
age at control harness  
(see insert a). Voltage  
shouldbe24V between  
thermostat or pressure  
switchand24Vcommon  
and 24V hot.  
• ensure Valveswitch isin onposition.  
• disconnectcontrolHarness.  
• set thermostat to callForHeat.  
no  
2
• Wiring  
Yes  
• plug control harness into  
valve. Wait for internal check  
delay.  
insert a  
end View of control Harness connector  
24 Volt  
common  
24 Volt Hot  
• With pilot burner cable con-  
nected, measure voltage at  
valveHsielementoutput. 24V  
nominal. (see insert B)  
1
no  
no  
• igniter warms up and glows  
red.  
• replacevalve.  
2
Yes  
Yes  
• replace igniter/flame rod  
assembly.  
1
24 Volt  
switched  
Yes  
check For damaged or Missing  
terminals in connector  
• check that pilot gas is owing. Wait  
to ensure pilot gas tubing is purged.  
recycle call for heat if necessary.  
no  
no  
no  
turnongassupply.  
pilotburnerlights.  
• replacevalve.  
insert B  
Yes  
• Measurevoltagebetween24Vhotand  
24V common leads to valve control.  
Must measure at least 19.5 Vac with  
igniter powered (see insert a). to  
identify proper lead, this check must  
be done with the valve control con-  
nected and igniter powered.  
igniter terminals  
• check transformer and  
line volt supply.  
Yes  
Yes  
replace pilotassembly.  
check that pilot ame makes good  
contact with pilot burner ame rod.  
• check for good electrical connection  
through the pilot tubing.  
Main valve opens and main  
burner lights.  
no  
• if both of the above are good, replace  
igniter/flame rod assembly.  
Yes  
Yes  
• systemisokay.  
cycle thermostat off and back on.  
Igniter will cycle off and  
back on once during the 90  
Whenmeasuringvoltage  
atconnections,usecare  
2
1
no  
second ignition trial. All  
voltage measurements must  
be taken while the igniter is  
powered.  
to ensure terminals are  
not damaged.  
Mainburnerlights.  
• replacevalve.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
note: tHis paGe intentionaLLY LeFt BLanK.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
repLaceMent parts List  
item #  
description  
LMdVt-3328 & LMdVr-3328  
LMdV-3530  
part no.  
LMdV-4035  
part no.  
part no.  
H4574  
H3375  
H3378  
H4575  
12L15  
69L21  
Qty.  
1
Qty.  
1
Qty.  
1
1
2
3
4
5
6
Hood  
97K51  
H3376  
H3379  
H4864  
12L15  
69L21  
97K52  
H3377  
H3380  
H3724  
12L15  
69L21  
Louver assembly, top, charcoal  
*Louver assembly, Bottom, charcoal  
enclosure, Glass Front (complete)  
nameplate, Lennox  
1
1
1
1
1
1
1
1
1
1
1
1
Latch  
2
2
2
7
8
Log set (complete)  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
H3366  
24M58  
39L66  
99K78  
88L53  
80L42  
H3696  
93L32  
H3366  
24M58  
60J80  
12L52  
88L53  
80L42  
H3696  
93L32  
H3365  
24M59  
24M10  
21L01  
88L53  
80L42  
H3696  
93L32  
Burner assembly  
9
orice, Main Burner - natural Gas  
orice, Main Burner - propane Gas  
Bag of Glowing embers (rockwool)  
Bag of decorative Volcanic stone  
Bag of Vermiculite  
9
10  
10  
10  
11  
Gas Line Flexible connector  
* Lennox nameplate Logo, 12L15, is sold separately.  
Gas controls - Honeywell Millivolt  
Gas controls - sit Millivolt  
natural Gas  
propane Gas  
natural Gas  
propane Gas  
part no.  
24M12  
24M89  
67L70  
60J79  
67L67  
67L68  
67L87  
H3737  
Qty.  
1
part no.  
82L87  
24M89  
67L70  
60J79  
67L67  
67L68  
67L87  
H3737  
Qty.  
1
part no.  
H1657  
10K86  
69L17  
60J79  
74L57  
74L56  
74L58  
H3737  
Qty.  
1
part no.  
88J53  
10K86  
69L18  
60J79  
74L57  
74L56  
74L58  
H3737  
Qty.  
1
20  
21  
22  
23  
24  
25  
26  
27  
Gas Valve, Honeywell  
12  
13  
14  
15  
16  
17  
18  
19  
Gas Valve, sit  
piezo igniter  
piezo igniter  
1
1
1
1
pilot assembly  
pilot Generator  
thermocouple  
pilot tube  
1
1
pilot assembly  
pilot Generator  
thermocouple  
pilot tube  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
electrode and cable  
pilot shield  
1
1
electrode and cable  
pilot shield  
1
1
1
1
1
1
Gas controls - Honeywell electronic  
natural Gas  
part no.  
62L18  
propane Gas  
part no.  
Qty.  
1
Qty.  
28  
29  
30  
31  
32  
Gas Valve, Honeywell  
pilot assembly  
62L19  
62L15  
42J32  
87L54  
H1596  
1
1
1
1
1
62L14  
1
transformer  
42J32  
1
igniter assembly (Kit)  
pilot shield  
87L54  
1
H1596  
1
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
repLaceMent parts  
LMdV-4035  
8
1
8
LMdVt-3328 & LMdVr-3530  
9
7
10  
2
13  
12  
18  
15  
6
19  
28  
16  
11  
20  
32  
17  
3
29  
14  
5
21  
26  
31  
27  
23  
22  
30  
4
24  
25  
note: diaGraMs & iLLustrations are not to scaLe.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design,  
materials, specifications, prices and also to discontinue colors, styles and products.  
Consult your local distributor for fireplace code information.  
Printed in U.S.A. © 2005 by LENNOX HEARTH PRODUCTS  
p/n 875,028M reV. e 02/2008  
1110 West Taft Avenue • Orange, CA 92865  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Trimmer YM132 User Manual
Multiquip Model Vehicle GX270UT2QA2 9HP User Manual
Multi Tech Systems Network Card CDMA Wireless Modem User Manual
Multi Tech Systems Network Card MTS2BTA User Manual
NAD CD Player C715 DAB User Manual
NEC Computer Monitor JC 1431VMB User Manual
One for All Universal Remote Univeral Remote User Manual
Oster Griddle CKSTGRFM40 User Manual
Panasonic Switch LC2H User Manual
Panasonic Vacuum Cleaner MC E761 User Manual