OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
Cat. No.
No de Cat.
2270-20
Contact Temp Meter
Dispositif de Mesure de la Température de Contact
Termómetro por Contacto
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
ASSEMBLY
OPERATION
MAINTENANCE
WARNING Always remove batteries
before changing or removing accessories. Only
use accessories specifically recommended for
this tool. Others may be hazardous.
WARNING Never connect the probe
WARNING To reduce the risk of injury,
always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a MILWAUKEE
service facility for ALL repairs.
WARNING To avoid an electrical
hazard, turn off the tool and disconnect the
thermocouples before replacing batteries.
to an energized circuit.
Making a Measurement
Loading/Changing the Batteries
Replace batteries when the Low Battery indicator
is displayed.
1. Turn meter OFF and disconnect the probes.
2. Unscrew and remove battery door.
3. Insert three (3) AA batteries, according to the
polarity marked in the battery compartment
Insert the probe into the input. Two probes can be
used simultaneously.
For a complete listing of accessories refer to your
MILWAUKEE Electric Tool catalog or go online
contact your local distributor or service center.
Maintaining Tool
Keep your tool in good repair by adopting a regular
maintenance program. After six months to one year,
depending on use, return the tool to a MILWAUKEE
service facility for repairs.
If the tool does not start or operate at full power
with new batteries, clean the contacts on the battery
door. If the tool still does not work properly, return
the tool to a MILWAUKEE service facility for repairs.
Press and hold the
button to turn the meter on.
The display will continue to update the contact
temperature while the temperature probe reaches
thermal equilibrium with the object being measured.
The display will switch to low backlight mode
5 minutes after the last button is pressed. The
meter will automatically power off after an additional
25 minutes if no buttons are pressed.
4. Close the battery door and tighten screws
securely.
If the low battery life indicator appears
, the
WARNING To reduce the risk of per-
sonal injury and damage, never immerse your
tool in liquid or allow a liquid to flow inside it.
meter will automatically power off 5 minutes after
the last button is pressed (replace the batteries as
soon as possible).
Cleaning
Press the
button or
button to start the
Clean dust and debris from tool. Keep tool clean, dry
and free of oil or grease. Use only mild soap and a
damp cloth to clean the tool since certain cleaning
agents and solvents are harmful to plastics and other
insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use flammable or
combustible solvents around tools.
timer and begin tracking the maximum, minimum
and average temperatures over time.
When the timer is activated the auto power off time
is extended to 30 hours.
Press the
button to toggle through the
minimum, maximum, and average readings. The
measurement time readings also toggle through
the minimum, maximum, and average.
Repairs
Press the
button to turn off the timer and
For repairs, return the tool to the nearest service
center listed on the back cover of this operator's
manual.
stop tracking minimum, maximum and average
temperatures.
Press the
button to toggle between Celsius
(°C) and Fahrenheit (°F).
Press the
button to hold or release the dis-
played readings.
Press the
button to change what is displayed
in the primary and secondary measurements.
Press and hold the button to turn the meter off.
5
4
Download from Www.Somanuals.com. All Manuals Search And Download.
FIVE YEAR TOOL LIMITED WARRANTY
MILWAUKEE Test & Measurement Product (including bare tool, M12™ battery pack(s) and battery
charger) is warranted to the original purchaser only to be free from defects in material and workmanship.
Subject to certain exceptions, MILWAUKEE will repair or replace any part on this product which, after
examination, is determined by MILWAUKEE to be defective in material or workmanship for a period of five
(5) years* after the date of purchase. Return of the Test & Measurement tool to the nearest Milwaukee
Electric Tool Corporation - factory Service Center, freight prepaid and insured is required. A copy of the
proof of purchase should be included with the return product. This warranty does not apply to damage
that MILWAUKEE determines to be from repairs made or attempted by anyone other than MILWAUKEE
authorized personnel, misuse, alterations, abuse, normal wear and tear, lack of maintenance, or accidents.
* See separate & distinct CORDLESS BATTERY PACK LIMITED WARRANTY statement for the warranty
period of the LITHIUM-ION battery pack that ships with Test & Measurement Product. *Alkaline battery
that ships with Test & Measurement Product is separately warranted by the alkaline battery manufacturer.
*The warranty period for a Voltage Detector with Work Light – 2201 20, Voltage Detector with LED –
2202-20 or M12™ 2-Beam Plumb Laser – 2230 20 is one (1) year from the date of purchase.
RÈGLES IMPORTANTES DE SÉCURITÉ
AVERTISSEMENT LIRE TOUTES LES RÈGLES ET LES INSTRUCTIONS
DE SÉCURITÉ. Ne pas suivre l’ensemble des avertissements et des instructions
peut entraîner une électrocution, un incendie et/ou des blessures graves. Conserver ces
instructions – Ce manuel d’utilisation contient des instructions importantes de sécurité et
de fonctionnement pour le dispositif de mesure de la température de contact MILWAUKEE.
Avant de l’utiliser, lire ce manuel d’utilisation et tous les autocollants apposés sur l’appareil.
les parties atteintes avec de l’eau. Si le liquide
SÉCURITÉ DU LIEU DE TRAVAIL
entre en contact avec les yeux, consulter un
•S’assurer que les enfants et les curieux se
médecin. Le liquide s'échappant des batteries
trouvent à une bonne distance pendant le fonc-
peut causer des irritations ou des brûlures.
tionnement du dispositif de mesure. S’il n’est
pas utilisé, ranger le dispositif de mesure de
ENTRETIEN
la température de contact hors de portée des
•Les réparations doivent être confiées à un
enfants et interdire à quiconque de l’utiliser si
technicien qualifié, utilisant exclusivement des
la personne ne connaît pas bien le produit ou
pièces identiques à celles d’origine. Le maintien
ces instructions.
Warranty Registration is not necessary to obtain the applicable warranty on MILWAUKEE product. The
manufacturing date of the product will be used to determine the warranty period if no proof of purchase
is provided at the time warranty service is requested.
de la sûreté de l’outil sera ainsi assuré.
ACCEPTANCE OF THE EXCLUSIVE REPAIRAND REPLACEMENT REMEDIES DESCRIBED HEREIN
IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT.
IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE THE PRODUCT. IN
NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL
OR PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES, LOSSES OR DE-
LAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN
ANY PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME
STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WAR-
RANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL. TO THE
EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUD-
ING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR USE OR PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED
BY LAW, SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE
EXPRESS WARRANTYAS DESCRIBED ABOVE. SOME STATES DO NOTALLOW LIMITATIONS ON
HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO
YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,AND YOU MAYALSO HAVE OTHER
RIGHTS WHICH VARY FROM STATE TO STATE.
•Éviter les environnements dangereux. Ne
•Ne pas désassembler l’appareil. Un remontage
pas utiliser sous la pluie ou la neige. Ne pas
incorrect peut entraîner des risques d’électrocution
plonger l’appareil de mesure dans de l’eau ni
ou d’incendie. En cas de dommage, confier
laisser l’eau s'infiltrer à l’intérieur. Ne pas utiliser
l’appareil à un centre de service MILWAUKEE.
l’appareil dans un endroit propice aux explosifs
•Entreposer le produit dans un endroit frais
(fumées gazeuses, poussières ou matériaux in-
et sec. Ne pas l’entreposer dans des endroits
flammables); l’insertion ou le retrait de la batterie
où la température peut dépasser 60 °C (140 °F)
pourrait alors créer des étincelles, ce qui risque
par exemple, un endroit exposé directement à la
de causer un incendie.
lumière du soleil, un véhicule ou une construction
en métal pendant l’été.
SÉCURITÉ INDIVIDUELLE
•Ne pas retirer ou endommager les étiquettes.
•Rester vigilant. Se concentrer sur son travail et
Maintenir en état les étiquettes et les plaques
faire preuve de bon sens en utilisant l’appareil.
signalétiques. Des informations importantes y
Ne pas utiliser cet appareil en cas de fatigue
figurent. Si elles sont illisibles ou manquantes,
ou sous l’influence de l’alcool, de drogues
contacter un centre de services et d’entretien
ou de médicaments. Un moment d’inattention
MILWAUKEE pour un remplacement gratuit.
pendant l’utilisation de ce produit peut résulter en
une blessure grave.
•Ne pas travailler hors de portée. Toujours se
This warranty applies to product sold in the U.S.A. and Canada only.
PICTOGRAPHIE
Lire le manuel d’utilisation
Prise de terre
tenir bien campé et en équilibre. Cela permet
un meilleur contrôle en cas d’imprévus.
•Ne jamais raccorder la sonde à un circuit sous
tension.
UTILISATION ET ENTRETIEN
DE LA BATTERIE
•Cet outil fonctionne avec trois piles AA qui
doivent être installées correctement dans le
dispositif de mesure de MILWAUKEE. Ne pas
tenter d’utiliser l’appareil à une autre tension ou
avec un autre type d’alimentation.
Danger, avertissement ou attention
- Consulter le manuel d’utilisation
afin de prendre connaissance
des renseignements de sécurité
supplémentaires.
•Ne pas laisser les piles à la portée des enfants.
•Ne pas mélanger des piles neuves et usées. Ne
pas mélanger des piles de marques différentes
(ou des piles de même marque mais de types
différents).
•Ne pas mélanger des piles rechargeables et
non rechargeables.
•Installer les piles en respectant la polarité (+
et -) indiquée.
Piles
Marque de conformité aux normes
européennes
Ne pas jeter ce produit avec les
ordures ménagères.
•Se débarrasser immédiatement des piles usées.
•Ne pas brûler ou démonter les piles.
•Éviter tout contact avec le liquide pouvant être
éjecté de la pile en cas d’emploi abusif. En cas
de contact accidentel, rincer immédiatement
7
6
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPTION FONCTIONNELLE
MONTAGE DE L'OUTIL
MANIEMENT
16
AVERTISSEMENT Pour éviter tout
risque d'électrocution, arrêter l'outil et dé-
brancher les thermocouples avant de rem-
placer les batteries.
AVERTISSEMENT Ne jamais rac-
9
15
1. Affichage
2. Marche/Arrêt
3. Sélecteur °C ou °F
4. Bouton de retenue
5. Sélecteur de mode
6. Bouton MARCHE
ARRÊT
7. Bouton AVG MIN MAX
8. Entrée T1-T2
9. Indicateur de charge
de pile
10. Mesure principale
11.Temps écoulé total
12.Temps MIN MAX
13.Indicateur de retenue
14.Mesure secondaire
15.Indicateur °C ou °F
16.Delta Entrée T1-T2
corder la sonde à un circuit sous tension.
1
Effectuer une mesure
10
11
Insérer la sonde dans l'entrée. Il est possible
d'utiliser deux sondes simultanément.
Charge et changement des piles
Remplacer les piles lorsque l'indicateur de faible
2
14
intensité s'affiche
.
Appuyer et maintenir enfoncé le bouton
mettre l’appareil en marche.
pour
1. Éteindre le dispositif de mesure et débrancher
les sondes.
12
2. Dévisser et retirer le compartiment des piles.
3. Insérer trois (3) pilesAA, en respectant la polarité
indiquée sur le compartiment des piles.
4. Fermer le couvercle du compartiment des piles
et serrer la vis solidement.
L’affichage continue de mettre à jour la tempéra-
ture de contact alors que la sonde thermique
atteint l’équilibre thermique avec l’objet mesuré.
L'affichage bascule en mode de faible intensité 5
minutes après avoir appuyé sur le dernier bouton.
L’appareil de mesure s'éteint automatiquement
après 25 minutes supplémentaires si aucun bouton
n'a été pressé.
3
7
6
13
4
8
5
Si l'indicateur de faible charge de pile apparaît
,
le dispositif de mesure s'éteint 5 minutes après
avoir appuyé sur le dernier bouton (remplacer les
piles dès que possible).
Appuyer sur le bouton
pour démarrer le minuteur et commencer à mesurer
les températures maximale, minimale et moyenne.
ou le bouton
Spécifications
Plage de température de contact : -200 °C à 1 372 °C (-328 °F à 2 501 °F)
Précision
Une fois le minuteur activé, le temps de la fonction
d’arrêt automatique s'étend à 30 heures.
Pour les températures ambiantes de18 °C à 28 °C (64 °F à 82 °F)
Mesures de -100 °C à 1 372 °C (-148 °F à 2 501 °F)
± (0,1 % de lecture + 0,7 °C)/(0,1 % de lecture +1,3 °F)
Appuyer sur le bouton
pour basculer entre
les lectures de température minimale, maximale
et moyenne. Les lectures de temps de mesure
permettent également de basculer entre les tem-
pératures minimale, maximale et moyenne.
Mesures de -200 °C à -100 °C (-328 °F à -148 °F)
± (0,4 % de lecture + 0,7 °C)/(0,4 % de lecture +1,3 °F)
Coefficient de température
Mesures de -100 °C à 1 372 °C (-148 °F à 2 501 °F)
(0,01 % de lecture + 0,05 °C) par degré C hors de la plage de température ambiante de 18 °C à 28 °C
(0,0056 % de lecture + 0,05 °F) par degré F hors de la plage de température ambiante de 64 °F à 82 °F
Mesures de -200 °C à -100 °C (-328 °F à -148 °F)
(0,04% de lecture + 0,05 °C) par degré C hors de la plage de température ambiante de 18 °C à 28 °C
(0,022 % de lecture + 0,05 °F) par degré F hors de la plage de température ambiante de 64 °F à 82 °F
Appuyer sur le bouton
pour éteindre le
minuteur et arrêter la mesure des températures
minimale, maximale et moyenne.
Appuyer sur le bouton
pour basculer entre
les degrés Celsius (°C) et Fahrenheit (°F).
Résolution de l’affichage de la température de contact : 0,1 °C/°F
Plage de température de la sonde de type K : -60 °C à 200 °C (-76 °F à 392 °F)
Appuyer sur le bouton
pour interrompre ou
afficher les lectures données.
Précision des données relatives à la température de la sonde de type K : ±1,1 °C ou ±0,4 % de
lecture, selon la plus grande des deux valeurs
Chute : 1 mètre
Appuyer sur le bouton
pour modifier le
Température de fonctionnement : -10 °C à 50 °C (14 °F à 122 °F)
Température de stockage : -40 °C à 60 °C (-40 °F à 140 °F)
contenu affiché dans les mesures principale et
secondaire.
Humidité relative : H.R. de 10 % à 90 % sans condensation à une température ambiante de 30 °C
Appuyer et maintenir enfoncé le bouton
arrêter l’appareil.
pour
(< 86 °F)
Piles : 3 piles AA de 4,5V CC, LR6
Autonomie des piles : supérieure à 12 heures pour toutes les fonctions
Conformités à la sécurité... EN61326-1,2; IEC61000-3-2,3; IEC61000-4-2,3,4,5,6; CISPR11; FCC
Partie 15
Certifications.... CE
9
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ENTRETIEN
ACCESSOIRES
GARANTIE LIMITÉE DE CINQ ANS
Chaque produit de test et de mesure MILWAUKEE (y compris les produits sans fil, les blocs-piles M12™
et les chargeurs de batterie) est garanti à l’acheteur d’origine être exempt de vice du matériau et de
fabrication. Sous réserve de certaines exceptions, MILWAUKEE réparera ou remplacera toute pièce
d’un produit qui, après examen par MILWAUKEE, s’est avérée être affectée d’un vice du matériau ou
de fabrication pendant une période de cinq (5) ans* après la date d’achat. Retourner l’outil de test et
de mesure au centre de réparations en usine Milwaukee Electric Tool Corporation le plus proche, en
port prépayé et assuré, est requis. Une copie de la preuve d’achat doit être présentée lors du retour du
produit. Cette garantie ne couvre pas les dommages que MILWAUKEE détermine être causés par des
réparations ou des tentatives de réparation par quiconque autre que le personnel agréé par MILWAUKEE,
des utilisations incorrectes, des altérations, des utilisations abusives, une usure normale, une carence
d’entretien ou les accidents.
AVERTISSEMENT Pour réduire le
risque de blessures, toujours retirer les piles
de l’outil avant de procéder à son entretien. Ne
jamais démonter l’outil. Pour TOUTE répara-
tion, communiquer avec un centre de service
MILWAUKEE.
AVERTISSEMENT Toujours retirer
les piles avant de changer ou de retirer des
accessoires. Utiliser seulement des acces-
soires conçus spécialement pour cet outil.
L’utilisation d’autres types d’accessoires peut
s’avérer dangereuse.
Pour obtenir une liste complète des accessoires,
consulter le catalogue des outils électriques de
MILWAUKEE ou visiter le site www.milwaukeetool.
com. Pour obtenir un catalogue, communiquer avec
le distributeur local ou un centre de réparations
indiqué au dos du présent manuel d’utilisation.
Entretien de l’outil
Garder l’outil en bon état en suivant un programme
d’entretien régulier. Après un an, il est recom-
mandé de confier l’outil à un centre de réparations
MILWAUKEE aux fins d’étalonnage.
Si l’outil ne démarre pas ou ne fonctionne pas à
pleine puissance, et ce, même si les piles sont
complètement chargées, nettoyer les contacts
sur la porte du compartiment des piles. Si l’outil
ne fonctionne toujours pas de façon appro-
priée, confier l’outil à un centre de réparations
MILWAUKEE aux fins de réparations.
* Consulter les énoncés de la GARANTIE LIMITÉE DES BLOCS-PILES SANS FIL pour connaître la
période de garantie du bloc-pile au LITHIUM-ION envoyé avec le produit de test et de mesure. * La
pile alcaline envoyée avec le produit de test et de mesure est garantie séparément par le fabricant de
la pile alcaline.
* La période de garantie d’un détecteur de tension avec la lampe – 2201 20, détecteur de tension à
LED – 2202-20 ou du laser vertical à deux faisceaux M12™– 2230 20 est de un (1) an à compter de
la date d’achat.
L’enregistrement de la garantie n’est pas nécessaire pour bénéficier de la garantie en vigueur sur un
produit MILWAUKEE. La date de fabrication du produit servira à établir la période de garantie si aucune
preuve d’achat n’est fournie lorsqu’une demande de service sous garantie est faite.
L’ACCEPTATION DES RECOURS EXCLUSIFS DE RÉPARATION ET DE REMPLACEMENT DÉCRITS
PAR LES PRÉSENTES EST UNE CONDITION DU CONTRAT D’ACHAT DE TOUT PRODUIT
MILWAUKEE. SI VOUS N’ACCEPTEZ PAS CETTE CONDITION, VOUS NE DEVEZ PASACHETER LE
PRODUIT. ENAUCUN CAS MILWAUKEE NE SAURAIT ÊTRE RESPONSABLE DE TOUT DOMMAGE
ACCESSOIRE, SPÉCIAL OU INDIRECT, DE DOMMAGES-INTÉRÊTS PUNITIFS OU DE TOUTE
DÉPENSE, D’HONORAIRES D’AVOCATS, DE FRAIS, DE PERTE OU DE DÉLAIS ACCESSOIRES
À TOUT DOMMAGE, DÉFAILLANCE OU DÉFAUT DE TOUT PRODUIT, Y COMPRIS NOTAMMENT
LES PERTES DE PROFIT. CERTAINS ÉTATS ET PROVINCES NE PERMETTANT L'EXCLUSION OU
LA LIMITATION DES DOMMAGES DIRECTS OU INDIRECTS, LES RESTRICTIONS CI-DESSOUS
PEUVENT NE PAS ÊTREAPPLICABLES. CETTE GARANTIE EST EXCLUSIVE ET REMPLACE TOUTE
AUTRE GARANTIE, QU’ELLE SOIT VERBALE OU ÉCRITE. DANS LA MESURE PERMISE PAR LA
LOI. MILWAUKEE RENONCE À TOUTE GARANTIE IMPLICITE, Y COMPRIS, SANS S’Y LIMITER,
TOUTE GARANTIE IMPLICITE DE QUALITÉ MARCHANDE OU D’ADAPTATION À UNE UTILISATION
OU À UNE FIN PARTICULIÈRE. DANS LAMESURE OÙ UNE TELLE STIPULATION D’EXONÉRATION
N’EST PAS PERMISE PAR LA LOI, LA DURÉE DE CES GARANTIES IMPLICITES EST LIMITÉE
À LA PÉRIODE APPLICABLE DE LA GARANTIE EXPRESSE, TEL QUE CELA EST DÉCRIT
PRÉCÉDEMMENT. CERTAINS ÉTATS ET PROVINCES NE PERMETTANT PAS DE LIMITATION DE
DURÉE DES GARANTIES IMPLICITES, LES RESTRICTIONS CIDESSUS PEUVENT NE PAS ÊTRE
APPLICABLES. LAPRÉSENTE CONFÈRE À L’UTILISATEUR DES DROITS LÉGAUX PARTICULIERS;
IL BÉNÉFICIE ÉGALEMENT D’AUTRES DROITS QUI VARIENT D’UN ÉTAT À L’AUTRE.
AVERTISSEMENT Pour réduire le
risque de blessures ou de dommages maté-
riels, ne jamais plonger l’outil dans un liquide
ou laisser un liquide s’infiltrer dedans.
Nettoyage
Nettoyer l’outil des débris et de la poussière. Garder
les poignées de l’outil propres, sèches et exemptes
d’huile ou de graisse. Utiliser uniquement du savon
doux et un linge humide pour nettoyer l’outil étant
donné que certains agents de nettoyage et certains
solvants peuvent détériorer le plastique et l’isolation
des pièces. En voici des exemples : l’essence, la
térébenthine, les diluants à laque ou à peinture, les
solvants chlorés, l’ammoniaque et les détergents
à usage domestique qui en contiennent. N’utiliser
aucun solvant inflammable ou combustible autour
des outils.
Réparations
Cette garantie s’applique aux produits vendus aux États-Unis et au Canada uniquement.
Pour toute réparation, confier l’outil au centre de
réparations le plus près indiqué au dos du présent
manuel d’utilisation.
11
10
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPCIÓN FUNCIONAL
INSTRUCCIONES IMPORTANTES
DE SEGURIDAD
16
1. Pantalla
2. ENCENDIDO/APAGADO
3. Selector de grados
centígrados o Fahrenheit
9
15
ADVERTENCIA LEA TODAS LAS ADVERTENCIAS E INSTRUCCIONES DE
SEGURIDAD. El incumplimiento de las advertencias e instrucciones podría provocar
una descarga eléctrica, incendio y/o lesiones graves. Guarde estas instrucciones -Este manual
del operador contiene instrucciones importantes de seguridad y operación para el termómetro
por contacto MILWAUKEE. Antes de utilizar el aparato, lea este manual del operador y todas las
etiquetas del aparato.
1
10
11
4. Botón de conservación
5. Selector de modo
6. Botón de INICIO PARO
7. Botón de MÍN MÁX PROM
8. Entrada T1-T2
14
2
también ayuda médica. El líquido expulsado de
SEGURIDAD EN EL ÁREA
12
la batería puede causar irritación o quemaduras.
9. Indicador de la vida de
la batería
10.Medición principal
11.Tiempo transcurrido total
12.Tiempo MÍN MÁX
13.Indicador de conservación
14.Medición secundaria
DE TRABAJO
7
6
MANTENIMIENTO
•Mantenga a los niños y a los espectadores
alejados mientras opera el termómetro. Alma-
cene los termómetros por contacto que no se
estén utilizando fuera del alcance de los niños
y no permita que las personas que no estén
familiarizadas con la herramienta o con estas
instrucciones la utilicen.
13
3
•Lleve su termómetro a servicio con un técnico
calificado que use únicamente piezas de reem-
plazo idénticas. Esto asegurará que la seguridad
de la herramienta se mantenga.
8
4
•No desensamble. El reensamble incorrecto
puede generar riesgo de descarga eléctrica o
incendio. Si se daña, llévelo a un centro de servicio
MILWAUKEE.
•Guarde en un lugar fresco y seco. No almacene
a temperaturas que pueden exceder los 140 °F
(60° C) como en la luz directa del sol, un vehículo
o un edificio de metal durante el verano.
•No quite ni mutile las etiquetas. Mantenga las
etiquetas y las placas nominales. Contienen
información importante. Si son ilegibles o no están
presentes, comuníquese con un centro de servicio
MILWAUKEEpara obtener un reemplazo gratuito.
15.Indicador de grados
centígrados o Fahrenheit
16. Delta Entrada T1-T2
5
•Evite los entornos peligrosos. No lo utilice en
la lluvia ni en la nieve. No sumerja el termómetro
en agua ni permita que fluya agua al interior del
termómetro. No lo use en presencia de atmósferas
explosivas (vapores de gases, polvo o materiales
inflamables), debido a que pueden generarse chis-
pas al insertar o extraer la batería, lo que podría
causar un incendio.
Especificaciones
SEGURIDAD PERSONAL
Rango de temperatura de contacto: -200°C a 1372°C (-328°F a 2501°F)
• Esté atento a lo que está haciendo y use el
sentido común al operar el termómetro. No lo
use mientras está cansado o bajo la influencia
de drogas, alcohol o medicamentos. Un mo-
mento de distracción puede ocasionar lesiones
personales graves.
Precisión
Para temperaturas ambiente de 18°C a 28°C (64°F a 82°F)
Mediciones de -100°C a 1372°C (-148°F a 2501°F)
± (0.1% de lectura + 0.7°C)/(0.1% de lectura +1.3°F)
Mediciones de -200°C a -100°C (-328°F a -148°F)
± (0.4% de lectura +0.7°C)/(0.4% de lectura +1.3°F)
SIMBOLOGÍA
•No estire demasiado el cuerpo. Mantenga un
buen contacto entre los pies y el suelo y man-
tenga el equilibrio en todo momento. Esto per-
mite un mejor control en situaciones inesperadas.
•Nunca conecte la sonda a un circuito ener-
getizado.
Lea el manual del operador
Coeficiente de temperatura
Mediciones de -100°C a 1372°C (-148°F a 2501°F)
(0.01% de lectura + 0.05°C) por grado C fuera de 18°C a 28°C ambiente
(0.0056% de lectura + 0.05°F) por grado F fuera de 64°F a 82°F ambiente
Mediciones de -200°C a -100°C (-328°F a -148°F)
(0.04% de lectura + 0.05°C) por grado C fuera de 18°C a 28°C ambiente
(0.022% de lectura + 0.05°F) por grado F fuera de 64°F a 82°F ambiente
Tierra
USO Y CUIDADO DE LAS
HERRAMIENTAS CON BATERÍA
Peligro, advertencia o precaución -
Consulte el manual del operador si
necesita más información de seguridad.
Resolución de pantalla de la temperatura de contacto: 0.1°C/°F
•Esta herramienta está diseñada para funcionar
con tres baterías AA debidamente insertadas
en el termómetro MILWAUKEE. No intente uti-
lizarla con otro voltaje o fuente de energía.
•No deje las baterías al alcance de los niños.
•No mezcle baterías nuevas y usadas. No
mezcle marcas (o tipos de la misma marca)
de baterías.
•Nomezclebateríasrecargablesynorecargables.
•Instale las baterías respetando los diagramas
de polaridad (+ / -).
•Deseche las baterías usadas inmediatamente
de la manera correcta.
Rango de temperatura de la sonda tipo K: -60°C a 200°C (-76°F a 392°F)
Precisión de entrada de la temperatura de la sonda tipo K: ±1.1°C o ±0.4% de la lectura, el que
sea mayor
Compartimiento de las baterías
Marca de Conformidad Europea
Caída: 1 metro
Temperatura de funcionamiento: -10°C a 50°C (14°F a 122°F)
Temperatura de almacenamiento: -40°C a 60°C (-40°F a 140°F)
Humedad relativa: 10 a 90% de humedad relativa sin condensación a <30°C (<86°F) temperatura
ambiente
No deseche este producto como
residuos municipales sin clasificar.
Baterías: 4.5V DC, 3 baterías AA, LR6
•No incinere ni desmantele las baterías.
•Bajo condiciones de maltrato, el líquido puede
ser expulsado de la batería, evite el contacto. En
caso de contacto accidental, lave con agua. Si el
líquido entra en contacto con los ojos, busque
Vida de la batería: Más de 80 horas con todas las funciones
Cumplimiento con normas de seguridad .... EN61326-1,2; IEC61000-3-2,3; IEC61000-4-2,3,4,5,6;
CISPR11; FCC Parte 15
Certificaciones .... CE
13
12
Download from Www.Somanuals.com. All Manuals Search And Download.
tiempo de medición también alternan entre mínimo,
máximo y promedio.
ENSAMBLAJE
ACCESORIOS
Para recibir una lista completa de los accesorios,
Presione el botón
para apagar el temporiza-
consulte su catálogo de herramientas eléctricas
MILWAUKEE o ingrese en www.milwaukeetool.com
en Internet. Para solicitar un catálogo, comuníquese
con su distribuidor local o con un centro de servicio.
ADVERTENCIAPara evitar un riesgo
eléctrico, apague la herramienta y desconecte
los termopares antes de cambiar las baterías.
ADVERTENCIA Siempre retire las
baterías antes de cambiar o retirar accesorios.
Use solamente accesorios específicamente
recomendados para esta herramienta. El uso
de otros accesorios puede resultar peligroso.
dor y dejar de llevar el control de las temperaturas
mínima, máxima y promedio.
Presione el botón
para alternar entre grados
centígrados (°C) y Fahrenheit (°F).
Carga/cambio de las baterías
Cambie las baterías cuando se muestre el indica-
Presione el botón
las lecturas mostradas.
para conservar o eliminar
dor de baja batería
.
1. Ponga el termómetro en APAGADO y desco-
necte las sondas.
Presione el botón
para cambiar lo que se
2. Desatornille y quite la puerta de las baterías.
3. Inserte tres (3) baterías AA, de acuerdo con
la polaridad marcada en el compartimiento de
baterías.
muestra en las mediciones principal y secundaria.
Presione y mantenga presionado el botón
para apagar el medidor.
4. Cierre la puerta de las baterías y apriete bien
el tornillo.
MANTENIMIENTO
ADVERTENCIAPara reducir el riesgo
de lesiones, retire siempre las baterías de la
herramienta antes de realizar mantenimiento.
Nunca desarme la herramienta. Comuníquese
con una instalación de servicio MILWAUKEE
para que se realicen TODAS las reparaciones.
GARANTÍA LIMITADA DE CINCO AÑOS DE LA HERRAMIENTA
El producto de medición y prueba de MILWAUKEE (incluida la herramienta sola, la(s) batería(s) M12™ y el
cargador de la batería) está garantizado para el comprador original como libre de defectos en materiales
y mano de obra. Sujeto a ciertas excepciones, MILWAUKEE reparará o reemplazará cualquier parte de
este producto que, tras una revisión, MILWAUKEE determine que es defectuoso en material o mano
de obra durante un período de cinco (5) años* después de la fecha de compra. Regrese la herramienta
de medición y prueba al Centro de Servicio de fábrica de Milwaukee Electric Tool Corporation más
cercano. Se requiere flete prepagado y seguro. Debe incluirse una copia del comprobante de compra
con el producto a devolver. Esta garantía no se aplica a los daños que MILWAUKEE determine que son
originados por reparaciones realizadas o intentadas por personas que no sean personal autorizado de
MILWAUKEE, mal uso, alteración, maltrato, uso y desgaste normal, falta de mantenimiento o accidentes.
* Consulte la declaración de GARANTÍA LIMITADA DE LA BATERÍA INALÁMBRICA, la cual es
independiente de esta garantía, donde encontrará el período de garantía de la batería de IONES DE
LITIO que se incluye con el producto de medición y prueba. *La batería alcalina que se incluye con el
producto de medición y prueba tiene una garantía por separado del fabricante de baterías alcalinas.
*El período de garantía de un detector de voltaje con la luz de trabajo – 2201-20, detector de voltaje con
LED - 2202-20 o plomada láser de 2 haces M12™ - 2230-20 es un (1) año a partir de la fecha de compra.
No es necesario el registro de la garantía para obtener la garantía correspondiente para un producto
MILWAUKEE. La fecha de fabricación del producto se utiliza para determinar el período de garantía si
no se proporciona comprobante de compra al momento de solicitar el servicio por garantía.
LAACEPTACIÓN DE LOS RECURSOS EXCLUSIVOS DE REPARACIÓN Y REEMPLAZO DESCRITOS
EN ESTE DOCUMENTO ES UNA CONDICIÓN DEL CONTRATO PARA LA COMPRA DE CADA
PRODUCTO MILWAUKEE. SI USTED NO ESTÁ DE ACUERDO CON ESTA CONDICIÓN, NO
DEBE COMPRAR EL PRODUCTO. EN NINGÚN CASO MILWAUKEE SERÁ RESPONSABLE POR
NINGÚN DAÑO INCIDENTAL, ESPECIAL, CONSECUENTE O PUNITIVO, NI POR LOS COSTOS,
HONORARIOS DE ABOGADOS, GASTOS, PÉRDIDAS O RETRASOS QUE PRESUNTAMENTE
SEAN CONSECUENCIADE CUALQUIER DAÑO, FALLAO DEFECTO DE CUALQUIER PRODUCTO,
INCLUYENDO, SIN LIMITACIONES, CUALQUIER RECLAMACIÓN POR PÉRDIDA DE UTILIDADES.
ALGUNOS ESTADOS NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE RESPONSABILIDAD
POR DAÑOS INCIDENTALES O EMERGENTES; POR LO TANTO, LA ANTERIOR LIMITACIÓN O
EXCLUSIÓN PODRÍANOAPLICARSE EN SU CASO. ESTAGARANTÍAES EXCLUSIVAY SUSTITUYE
CUALQUIER OTRA GARANTÍA EXPRESA, ORAL O ESCRITA. EN LA MEDIDA QUE LO PERMITA
LA LEY, MILWAUKEE SE DESLINDA DE CUALQUIER GARANTÍA IMPLÍCITA, INCLUYENDO
SIN LIMITACIÓN CUALQUIER GARANTÍA IMPLÍCITA DE COMERCIALIZACIÓN O IDONEIDAD
PARA UN USO O PROPÓSITO PARTICULAR, EN LA MEDIDA EN QUE DICHA EXENCIÓN DE
RESPONSABILIDAD NO SEAPERMITIDAPOR LALEY, DICHAS GARANTÍAS IMPLÍCITAS SE LIMITAN
ALADURACIÓN DE LAGARANTÍAEXPLÍCITAAPLICABLE DESCRITAANTERIORMENTE.ALGUNOS
ESTADOS NO PERMITEN LALIMITACIÓN DE LADURACIÓN DE LAS GARANTÍAS IMPLÍCITAS, POR
LO QUE LAANTERIOR LIMITACIÓN PODRÍA NO SER APLICABLE EN SU CASO; ESTA GARANTÍA
LE OTORGA DERECHOS LEGALES ESPECÍFICOS Y USTED PUEDE TENER ADEMÁS OTROS
DERECHOS QUE VARÍAN DE UN ESTADO A OTRO.
Mantenimiento de la herramienta
Mantenga su herramienta en buenas condiciones
adoptando un programa de mantenimiento
regular. Después de un año, se recomienda que
envíe la herramienta a una instalación de servicio
MILWAUKEE para que la calibren.
OPERACION
ADVERTENCIA Nunca conecte la
sonda a un circuito energetizado.
Si la herramienta no enciende o no funciona al
máximo de potencia con baterías completamente
cargadas, limpie los contactos de la puerta de
las baterías. Si la herramienta aún no funciona
correctamente, envíela a una instalación de
servicio MILWAUKEE para que la reparen.
Para hacer una medición
Inserte la sonda en la entrada. Dos sondas pueden
usarse simultáneamente.
Presione y mantenga presionado el botón
para encender el medidor.
La pantalla seguirá actualizando la temperatura de
contacto mientras la sonda de temperatura llegue
al equilibrio térmico con el objeto que se está mi-
diendo. La pantalla cambiará al modo de baja luz
de fondo número 5 minutos después de que se
haya presionado el último botón. El termómetro se
apagará automáticamente después de 25 minutos
más si no se presionan botones.
ADVERTENCIA Para reducir el
riesgo de lesiones personales y daños,
nunca sumerja la herramienta en un líquido
ni permita que un líquido ingrese en esta.
Limpieza
Limpie el polvo y los residuos de la herramienta.
Mantenga los mangos de la herramienta limpios,
secos y sin aceite o grasa. Use solamente
jabón suave o un trapo húmedo para limpiar la
herramienta, ya que algunos agentes de limpieza
y solventes son dañinos para plásticos y otras
partes aisladas. Algunos de éstos son la gasolina,
aguarrás, decapante para laca, decapante
para pintura, solventes para limpieza con cloro,
amoníaco y detergentes domésticos que contienen
amoníaco. Nunca use solventes inflamables o
combustibles cerca de las herramientas.
Si aparece el indicador de baja batería
, el ter-
mómetro automáticamente se apagará 5 minutos
después de que se haya presionado el último botón
(reemplace las baterías en cuanto sea posible).
Presione el botón
o
para iniciar el
temporizador y empezar a llevar el control de las
temperaturas máxima, mínima y promedio a lo
largo del tiempo.
Cuando se activa el temporizador, el tiempo de
apagado automático se extiende a 30 horas.
Reparaciones
Presione el botón
para alternar entre las lec-
Para realizar reparaciones, envíe la herramienta
al centro de servicio más cercano que figure en la
contraportada de este manual del operador.
turas mínima, máxima y promedio. Las lecturas del
Esta garantía se aplica a productos vendidos en los EE.UU. y Canadá únicamente.
15
14
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITED STATES
CANADA - Service MILWAUKEE
MILWAUKEE Service
MILWAUKEE prides itself in producing a premium
®
quality product that is NOTHING BUT HEAVY DUTY .
Your satisfaction with our products is very impor-
tant to us!
If you encounter any problems with the operation
of this tool, or you would like to locate the factory
Service/Sales Support Branch or authorized ser-
vice station nearest you, please call...
MILWAUKEE prides itself in producing a premium
quality product that is NOTHING BUT HEAVY DUTY .
Your satisfaction with our products is very impor-
tant to us! If you encounter any problems with the
operation of this tool, or you would like to locate the
factory Service/Sales Support Branch or authorized
service station nearest you, please call...
®
Additionally, we have a nationwide network of
authorized Distributors ready to assist you with
your tool and accessory needs. Check your “Yellow
Pages” phone directory under “Tools-Electric” for
thenames&addressesofthosenearestyouorsee
the 'Where To Buy' section of our website.
1.800.268.4015
Monday – Friday 7:00 – 4:30 CST
fax: 866.285.9049
Milwaukee Electric Tool (Canada) Ltd
140 Fernstaff Court, Unit 4
Vaughan, ON L4K 3L8
18129 111 Avenue NW
Edmonton, AB T5S 2P2
1-800-SAWDUST
(1.800.729.3878)
Additionally, we have a nationwide network of
authorizedDistributorsreadytoassistyouwithyour
tool and accessory needs. Call 1.800.268.4015 to
find the names and addresses of the closest re-
tailers or consult “Where to buy” on our Web site
Monday-Friday
7:00 AM - 6:30 PM
Central Time
or visit our website at
MILWAUKEE est fier de proposer un produit de
For service information, use the 'Service Center
Search' icon found in the 'Parts & Service' section.
®
première qualité NOTHING BUT HEAVY DUTY . Votre
satisfaction est ce qui compte le plus!
Contact our Corporate After Sales Service
Technical Support about ...
•Technical Questions
En cas de problèmes d’utilisation de l’outil ou pour
localiser le centre de service/ventes ou le centre
d’entretien le plus proche, appelez le...
•Service/Repair Questions
•Warranty
1.800.268.4015
Lundi – Vendredi 7:00 – 4:30 CST
fax: 866.285.9049
call: 1-800-SAWDUST
fax: 1.800.638.9582
email: [email protected]
Milwaukee Electric Tool (Canada) Ltd
140 Fernstaff Court, Unit 4
Vaughan, ON L4K 3L8
18129 111 Avenue NW
Edmonton, AB T5S 2P2
Register your tool online at
• receive important notifications regarding
your purchase
• ensure that your tool is protected under the
warranty
• become a HEAVY DUTY club member
Notre réseau national de distributeurs agréés se
tient à votre disposition pour fournir l’aide tech-
nique, l’outillage et les accessoires nécessaires.
Composez le 1.800.268.4015 pour obtenir les
noms et adresses des revendeurs les plus proches
ou bien consultez la section «Où acheter» sur notre
site web à l’adresse www.milwaukeetool.com
MEXICO - Soporte de Servicio MILWAUKEE
CENTRO DE ATENCIÓN A CLIENTES
Av Presidente Mazarik 29 Piso 7
11570 Chapultepec Morales
Registre su herramienta en línea, en
• reciba importantes avisos sobre su compra
• asegúrese de que su herramienta esté prote-
gida por la garantía
Miguel Hidalgo, Distrito Federal, Mexico
Telefono 52 55 4160-3547
e-mail: [email protected]
• conviértase en integrante de Heavy Duty
Adicionalmente, tenemos una red nacional de
distribuidores autorizados listos para ayudarle con
su herramienta y sus accesorios. Por favor, llame
al 01 800 832 1949 para obtener los nombres y
direcciones de los más cercanos a usted, o con-
sulte la sección ‘Where to buy’ (Dónde comprar)
de nuestro sitio web en
MILWAUKEE ELECTRIC TOOL CORPORATION
13135 West Lisbon Road • Brookfield, Wisconsin, U.S.A. 53005
58-14-2270d3
01/13
Printed in Taiwan
Download from Www.Somanuals.com. All Manuals Search And Download.
|