Miller Electric Welding System Big 40G User Manual

OM-477  
116 508W  
September 2000  
Processes  
Stick (SMAW) Welding  
Air Carbon Arc (CAC-A)  
Cutting and Gouging  
With Optional Equipment:  
TIG (GTAW) Welding  
MIG (GMAW) Welding  
Flux Cored (FCAW) Welding  
Description  
Engine Driven Welding Generator  
R
Big 40G  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Engine Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-4. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .  
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .  
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Dangers relatifs au soudage à larc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Dangers existant en relation avec le moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
2
3
4
4
5
5
5
6
WARNING  
This product, when used  
for welding or cutting,  
produces fumes or  
gases which contain  
chemicals known to the  
State of California to  
cause birth defects and,  
in some cases, cancer.  
(California Health &  
Safety Code Section  
25249.5 et seq.)  
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7
8
1-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-6. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-1. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 3 – SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-1. Weld, Power, And Engine Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-2. Dimensions, Weights, And Operating Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-3. Fuel Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-4. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-5. AC Auxiliary Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-6. Optional AC Power Plant Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-7. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
8
9
9
WARNING  
9
9
Battery posts, terminals  
and related accessories  
contain lead and lead  
compounds, chemicals  
known to the State of  
California to cause  
cancer and birth defects  
or other reproductive  
harm. Wash hands after  
handling.  
10  
10  
11  
11  
12  
13  
SECTION 4 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
4-1. Installing Welding Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-2. Connecting The Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-3. Installing Muffler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-4. Engine Prestart Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-5. Connecting To Weld Output Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-6. Selecting Weld Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-7. Remote 14 Receptacle RC3 Information (Optional, See Section 4-8) . . . . . . . . . . . . . . . . . .  
4-8. Terminal Strip 3T Connections (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
14  
14  
14  
15  
16  
16  
17  
17  
WARNING  
The engine exhaust from  
this product contains  
chemicals known to the  
State of California to  
cause cancer, birth  
defects, or other  
SECTION 5 – OPERATING WELDING GENERATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
5-1. Front Panel Controls (See Section 5-2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-2. Description Of Front Panel Controls (See Section 5-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-3. Remote Control (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
18  
19  
20  
reproductive harm.  
SECTION 6 – OPERATING AUXILIARY EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
6-1. 120 Volt Duplex And Optional GFCI Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-2. 240 Volt Duplex Receptacle (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-3. Connecting Optional Auxiliary Power Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
21  
22  
23  
The following terms are  
used interchangeably  
throughout this manual:  
TIG = GTAW  
SECTION 7 – MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
7-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-2. Maintenance Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-3. Servicing Air Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-4. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-5. Changing Engine Oil And Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-6. Changing Fuel Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-7. Inspecting And Cleaning Optional Spark Arrestor Muffler . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-8. Adjusting Engine Weld/Power Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-9. Adjusting Engine Idle Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-10. Adjusting Governor Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-11. Adjusting Optional High Altitude Carburetor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-12. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
24  
25  
26  
26  
27  
28  
28  
29  
30  
30  
31  
31  
Stick = SMAW  
SECTION 8 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
SECTION 9 – AUXILIARY POWER GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
SECTION 10 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
OPTIONS AND ACCESSORIES  
WARRANTY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
rom _nd_11/98  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
Y
Marks a special safety message.  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
.
M
e
a
n
s
N
o
t
e
;
n
o
t
s
a
f
e
t
y
r
e
l
a
t
e
d
.
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-5. Read and follow all  
Safety Standards.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
D
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
During operation, keep everybody, especially children, away.  
SIGNIFICANT DC VOLTAGE exists after stopping  
engine on inverters.  
ELECTRIC SHOCK can kill.  
D
Stop engine on inverter and discharge input capacitors according  
to instructions in Maintenance Section before touching any parts.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
ARC RAYS can burn eyes and skin.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
Wear a welding helmet fitted with a proper shade of filter to protect  
your face and eyes from arc rays and sparks when welding or  
watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).  
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
Use protective screens or barriers to protect others from flash and  
glare; warn others not to watch the arc.  
D
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
Wear protective clothing made from durable, flame-resistant mate-  
rial (wool and leather) and foot protection.  
D
D
Use AC output ONLY if required for the welding process.  
If AC output is required, use remote output control if present on  
unit.  
FUMES AND GASES can be hazardous.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
D
Properly install and ground this equipment according to its  
Owners Manual and national, state, and local codes.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
If inside, ventilate the area and/or use exhaust at the arc to remove  
welding fumes and gases.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
If ventilation is poor, use an approved air-supplied respirator.  
Read the Material Safety Data Sheets (MSDSs) and the  
manufacturers instructions for metals, consumables, coatings,  
cleaners, and degreasers.  
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
D
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Frequently inspect input power cord for damage or bare wiring –  
replace cord immediately if damaged bare wiring can kill.  
D
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
If earth grounding of the workpiece is required, ground it directly  
with a separate cable.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and if necessary, while wearing an  
air-suppliedrespirator. The coatings and any metals containing  
these elements can give off toxic fumes if welded.  
D
D
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
OM-477 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WELDING can cause fire or explosion.  
HOT PARTS can cause severe burns.  
D
D
Allow cooling period before maintaining.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
Wear protective gloves and clothing when  
working on a hot engine.  
D
Do not touch hot engine parts or just-welded  
parts bare-handed.  
NOISE can damage hearing.  
D
D
D
Protect yourself and others from flying sparks and hot metal.  
Do not weld where flying sparks can strike flammable material.  
Noise from some processes or equipment can  
damagehearing.  
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
D
Wear approved ear protection if noise level is  
high.  
D
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
MAGNETIC FIELDS can affect pacemakers.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
D
D
Pacemaker wearers keep away.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock and fire hazards.  
CYLINDERS can explode if damaged.  
D
D
Do not use welder to thaw frozen pipes.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, slag, open flames, sparks, and arcs.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
FLYING METAL can injure eyes.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
D
Wear approved safety glasses with side  
shields even under your welding helmet.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
BUILDUP OF GAS can injure or kill.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
D
Shut off shielding gas supply when not in use.  
Always ventilate confined spaces or use ap-  
proved air-supplied respirator.  
D
Read and follow instructions on compressed gas cylinders,  
associated equipment, and CGA publication P-1 listed in Safety  
Standards.  
1-3. Engine Hazards  
STEAM AND HOT COOLANT can burn.  
FUEL can cause fire or explosion.  
D
D
If possible, check coolant level when engine is  
cold to avoid scalding.  
D
D
Stop engine and let it cool off before checking or  
adding fuel.  
Always check coolant level at overflow tank, if  
present on unit, instead of radiator (unless told  
otherwise in maintenance section or engine  
manual).  
Do not add fuel while smoking or if unit is near  
any sparks or open flames.  
D
If the engine is warm, checking is needed, and  
there is no overflow tank, follow the next two  
statements.  
D
D
D
Do not overfill tank allow room for fuel to expand.  
Do not spill fuel. If fuel is spilled, clean up before starting engine.  
Dispose of rags in a fireproof container.  
D
D
Wear safety glasses and gloves and put a rag over radiator cap.  
Turn cap slightly and let pressure escape slowly before completely  
removing cap.  
OM-477 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY ACID can BURN SKIN and  
EYES.  
MOVING PARTS can cause injury.  
D
D
Keep away from fans, belts, and rotors.  
D
D
D
Do not tip battery.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
Replace damaged battery.  
Flush eyes and skin immediately with water.  
D
D
Stop engine before installing or connecting unit.  
Have only qualified people remove guards or covers for maint-  
enance and troubleshooting as necessary.  
D
D
D
D
D
To prevent accidental starting during servicing, disconnect  
negative () battery cable from battery.  
ENGINE EXHAUST GASES can kill.  
Keep hands, hair, loose clothing, and tools away from moving  
parts.  
D
D
Use equipment outside in open, well-ventilated  
areas.  
Reinstall panels or guards and close doors when servicing is  
finished and before starting engine.  
If used in a closed area, vent engine exhaust  
outside and away from any building air intakes.  
Before working on generator, remove spark plugs or injectors to  
keep engine from kicking back or starting.  
Block flywheel so that it will not turn while working on generator  
components.  
ENGINE HEAT can cause fire.  
D
D
Do not locate unit on, over, or near combustible  
surfaces or flammables.  
BATTERY EXPLOSION can BLIND.  
Keep exhaust and exhaust pipes way from  
flammables.  
D
D
Always wear a face shield, rubber gloves, and  
protective clothing when working on a battery.  
Stop engine before disconnecting or connect-  
ing battery cables or servicing battery.  
EXHAUST SPARKS can cause fire.  
D
D
D
D
Do not allow tools to cause sparks when working on a battery.  
Do not use welder to charge batteries or jump start vehicles.  
Observe correct polarity (+ and ) on batteries.  
D
D
Do not let engine exhaust sparks cause fire.  
Use approved engine exhaust spark arrestor in  
required areas see applicable codes.  
Disconnect negative () cable first and connect it last.  
1-4. Additional Symbols For Installation, Operation, And Maintenance  
FALLING UNIT can cause injury.  
OVERUSE can cause OVERHEATING.  
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, trailer, or any other  
accessories.  
D
D
Allow cooling period; follow rated duty cycle.  
Reduce current or reduce duty cycle before  
starting to weld again.  
D
Use equipment of adequate capacity to lift and  
support unit.  
D
Do not block or filter airflow to unit.  
D
If using lift forks to move unit, be sure forks are long enough to  
extend beyond opposite side of unit.  
STATIC (ESD) can damage PC boards.  
D
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
FLYING SPARKS can cause injury.  
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
D
D
Wear a face shield to protect eyes and face.  
Shape tungsten electrode only on grinder with  
proper guards in a safe location wearing proper  
face, hand, and body protection.  
TILTING OF TRAILER can cause injury.  
D
Sparks can cause fires keep flammables away.  
D
D
Use tongue jack or blocks to support weight.  
Properly install welding generator onto trailer  
according to instructions supplied with trailer.  
OVERHEATING can damage motors.  
D
Turn off or unplug equipment before starting or  
stopping engine.  
READ INSTRUCTIONS.  
D
Do not let low voltage and frequency caused by  
low engine speed damage electric motors.  
D
D
Use only genuine MILLER replacement parts.  
Perform engine maintenance and service  
according to this manual and the engine  
manual.  
D
Do not connect 50 or 60 Hertz motors to the 100 Hertz receptacle  
where applicable.  
OM-477 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
H.F. RADIATION can cause interference.  
ARC WELDING can cause interference.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
D
Have only qualified persons familiar with  
electronic equipment perform this installation.  
D
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
D
D
Have the installation regularly checked and maintained.  
Be sure this welding machine is installed and grounded  
according to this manual.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
1-5. Principal Safety Standards  
Safety in Welding and Cutting, ANSI Standard Z49.1, from American  
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-  
dent of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
Boulevard, Rexdale, Ontario, Canada M9W 1R3.  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers That Have Held Hazardous Substances, American  
Welding Society Standard AWS F4.1, from American Welding Society,  
550 N.W. LeJeune Rd, Miami, FL 33126  
Safe Practices For Occupation And Educational Eye And Face  
Protection, ANSI Standard Z87.1, from American National Standards  
Institute, 1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting And Welding Processes, NFPA Standard 51B, from National  
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
1-6. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from  
operator as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
To reduce magnetic fields in the workplace, use the following  
procedures:  
Pacemaker wearers consult your doctor first. If cleared by your doctor,  
then following the above procedures is recommended.  
OM-477 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 CONSIGNES DE SÉCURITÉ – LIRE AVANT  
UTILISATION  
rom _nd_fre 11/98  
1-1. Signification des symboles  
SignifieMise en garde ! Soyez vigilant ! Cette procédure  
présente des risques de danger ! Ceux-ci sont identifiés  
par des symboles adjacents aux directives.  
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des  
Y
Identifie un message de sécurité particulier.  
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN  
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles  
et aux directives ci-dessous afin de connaître les mesures à prendre pour  
éviter tout danger.  
.
S
i
g
n
i
f
i
e
N
O
T
A
;
n
e
s
t
p
a
s
r
e
l
a
t
i
f
à
l
a
s
é
c
u
r
i
t
é
.
1-2. Dangers relatifs au soudage à larc  
D
Nutiliser quun matériel en bon état. Réparer ou remplacer sur-le-champ  
les pièces endommagées. Entretenir lappareil conformément à ce  
manuel.  
Y
Les symboles présentés ci-après sont utilisés tout au long du  
présent manuel pour attirer votre attention et identifier les ris-  
ques de danger. Lorsque vous voyez un symbole, soyez  
vigilant et suivez les directives mentionnées afin d’éviter tout  
danger. Les consignes de sécurité présentées ci-après ne font  
que résumer linformation contenue dans les normes de sécu-  
rité énumérées à la section 1-5. Veuillez lire et respecter toutes  
ces normes de sécurité.  
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.  
Maintenir solidement en place tous les panneaux et capots.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec  
la pièce à souder ou la table de travail, le plus près possible de la soudure.  
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
D
avec tout objet métallique.  
Y
Y
Linstallation, lutilisation, lentretien et les réparations ne  
doivent être confiés qu’à des personnes qualifiées.  
Une tension DC importante subsiste à lintérieur  
des onduleurs après avoir coupé lalimentation.  
D
Couper lalimentation du poste et décharger les condensateurs dentrée  
comme indiqué dans la Section Maintenance avant de toucher des compo-  
sants.  
Au cours de lutilisation, tenir toute personne à l’écart et plus  
particulièrement les enfants.  
LES RAYONS DE LARC peuvent pro-  
voquer des brûlures dans les yeux et  
sur la peau.  
Le rayonnement de larc du procédé de soudage génère  
des rayons visibles et invisibles intenses (ultraviolets et  
UN CHOC ÉLECTRIQUE peut tuer.  
Un simple contact avec des pièces électriques peut  
provoquer une électrocution ou des blessures graves.  
L’électrode et le circuit de soudage sont sous tension dès  
que lappareil est sur ON. Le circuit dentrée et les circuits  
internes de lappareil sont également sous tension à ce  
infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la  
peau. Des étincelles sont projetées pendant le soudage.  
moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le  
logement des galets dentraînement et les pièces métalliques en contact avec  
le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la  
terre présentent un danger.  
D
Porter un casque de soudage muni dun écran de filtre approprié pour pro-  
téger votre visage et vos yeux pendant le soudage ou pour regarder (voir  
ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
D
D
Ne jamais toucher les pièces électriques sous tension.  
D
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est  
trop élevé.  
Porter des gants et des vêtements de protection secs ne comportant pas  
de trous.  
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de  
l’éblouissement; demander aux autres personnes de ne pas regarder larc.  
Porter des vêtements de protection constitué dans une matière durable, ré-  
sistant au feu (laine ou cuir) et une protection des pieds.  
D
Sisoler de la pièce et de la terre au moyen de tapis ou dautres moyens iso-  
lants suffisamment grands pour empêcher le contact physique éventuel  
avec la pièce ou la terre.  
D
D
D
D
Ne pas se servir de source électrique àcourant électrique dans les zones  
humides, dans les endroits confinés ou là où on risque de tomber.  
LES FUMÉES ET LES GAZ peuvent  
être dangereux.  
Se servir dune source électrique àcourant électrique UNIQUEMENT si le  
procédé de soudage le demande.  
Le soudage génère des fumées et des gaz. Leur inhalation  
peut être dangereux pour votre santé.  
Si lutilisation dune source électrique àcourant électrique savère néces-  
saire, se servir de la fonction de télécommande si lappareil en est équipé.  
Couper lalimentation ou arrêter le moteur avant de procéder à linstallation,  
à la réparation ou à lentretien de lappareil. Déverrouiller lalimentation  
selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).  
D
D
Eloigner votre tête des fumées. Ne pas respirer les fumées.  
À linterieur, ventiler la zone et/ou utiliser un échappement au niveau de  
larc pour l’évacuation des fumées et des gaz de soudage.  
D
D
Installer et mettre à la terre correctement cet appareil conformément à son  
manuel dutilisation et aux codes nationaux, provinciaux et municipaux.  
D
D
Si la ventilation est insuffisante, utiliser un respirateur à alimentation dair  
homologué.  
Toujours vérifier la terre du cordon dalimentation Vérifier et sassurer que  
le fil de terre du cordon dalimentation est bien raccordé à la borne de terre  
du sectionneur ou que la fiche du cordon est raccordée à une prise  
correctement mise à la terre.  
Lire les spécifications de sécurité des matériaux (MSDSs) et les instruc-  
tions du fabricant concernant les métaux, les consommables, les  
revêtements, les nettoyants et les dégraisseurs.  
D
Travailler dans un espace fermé seulement sil est bien ventilé ou en por-  
tant un respirateur à alimentation dair. Demander toujours à un surveillant  
dûment formé de se tenir à proximité. Des fumées et des gaz de soudage  
peuvent déplacer lair et abaisser le niveau doxygène provoquant des  
blessures ou des accidents mortels. Sassurer que lair de respiration ne  
présente aucun danger.  
D
D
En effectuant les raccordements dentrée fixer dabord le conducteur de  
mise à la terre approprié et contre-vérifier les connexions.  
Vérifier fréquemment le cordon dalimentation pour voir sil nest pas en-  
dommagé ou dénudé – remplacer le cordon immédiatement sil est  
endommagé – un câble dénudé peut provoquer une électrocution.  
D
D
Ne pas souder dans des endroits situés à proximité dopérations de dé-  
graissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de  
larc peuvent réagir en présence de vapeurs et former des gaz hautement  
toxiques et irritants.  
D
D
Mettre lappareil hors tension quand on ne lutilise pas.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou  
mal épissés.  
Ne pas souder des métaux munis dun revêtement, tels que lacier galvani-  
sé, plaqué en plomb ou au cadmium à moins que le revêtement nait été  
enlevé dans la zone de soudure, que lendroit soit bien ventilé, et si néces-  
saire, en portant un respirateur à alimentation dair. Les revêtements et  
tous les métaux renfermant ces éléments peuvent dégager des fumées  
toxiques en cas de soudage.  
D
D
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct ne pas utiliser le connecteur de pièce ou le câble de retour.  
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou  
une électrode provenant dune autre machine.  
OM-477 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LE SOUDAGE peut provoquer un in-  
cendie ou une explosion.  
DES PIÈCES CHAUDES peuvent  
provoquer des brûlures graves.  
D
Prévoir une période de refroidissement avant deffec-  
tuer des travaux dentretien.  
Le soudage effectué sur des conteneurs fermés tels que  
des réservoirs, tambours ou des conduites peut provoquer  
leur éclatement. Des étincelles peuvent être projetées de  
D
Porter des gants et des vêtements de protection pour  
larc de soudure. La projection d’étincelles, des pièces chaudes et des  
équipements chauds peut provoquer des incendies et des brûlures. Le contact  
accidentel de l’électrode avec des objets métalliques peut provoquer des  
étincelles, une explosion, un surchauffement ou un incendie. Avant de  
commencer le soudage, vérifier et sassurer que lendroit ne présente pas de  
danger.  
travailler sur un moteur chaud.  
D
Ne pas toucher à mains nues les parties chaudes du moteur ni les pièces  
récemment soudées.  
LE BRUIT peut affecter louïe.  
D
D
D
Se protéger et dautres personnes de la projection d’étincelles et de métal  
chaud.  
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des  
substances inflammables.  
Le bruit des processus et des équipements peut affecter  
louïe.  
Déplacer toutes les substances inflammables à une distance de 10,7 m de  
larc de soudage. En cas dimpossibilité les recouvrir soigneusement avec  
des protections homologués.  
D
Porter des protections approuvés pour les oreilles si  
le niveau sondre est trop élevé.  
D
Des étincelles et des matériaux chauds du soudage peuvent facilement  
passer dans dautres zones en traversant de petites fissures et des  
ouvertures.  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
D
D
Surveiller tout déclenchement dincendie et tenir un extincteur à proximité.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation peut dé-  
clencher un incendie de lautre côté.  
D
D
Porteurs de stimulateur cardiaque, restez à distance.  
D
D
Ne pas effectuer le soudage sur des conteneurs fermés tels que des réser-  
voirs, tambours, ou conduites, à moins quils naient été préparés  
correctement conformément à AWS F4.1 (voir les normes de sécurité).  
Les porteurs dun stimulateur cardiaque doivent  
dabord consulter leur médecin avant de sapprocher  
des opérations de soudage à larc, de gougeage ou  
de soudage par points.  
Brancher le câble sur la pièce le plus près possible de la zone de soudage  
pour éviter le transport du courant sur une longue distance par des che-  
mins inconnus éventuels en provoquant des risques d’électrocution et  
dincendie.  
Si des BOUTEILLES sont endomma-  
gées, elles pourront exploser.  
Des bouteilles de gaz protecteur contiennent du gaz sous  
haute pression. Si une bouteille est endommagée, elle peut  
exploser. Du fait que les bouteilles de gaz font normale-  
ment partie du procédé de soudage, les manipuler avec  
précaution.  
D
D
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.  
En cas de non utilisation, enlever la baguette d’électrode du porte-électro-  
de ou couper le fil à la pointe de contact.  
D
D
Porter des vêtements de protection dépourvus dhuile tels que des gants  
en cuir, une chemise en matériau lourd, des pantalons sans revers, des  
chaussures hautes et un couvre chef.  
Avant de souder, retirer toute substance combustible de vos poches telles  
quun allumeur au butane ou des allumettes.  
D
Protéger les bouteilles de gaz comprimé dune chaleur excessive, des  
chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des  
arcs.  
DES PARTICULES VOLANTES  
peuvent blesser les yeux.  
D
D
Placer les bouteilles debout en les fixant dans un support stationnaire ou  
dans un porte-bouteilles pour les empêcher de tomber ou de se renverser.  
D
Le soudage, l’écaillement, le passage de la pièce  
à la brosse en fil de fer, et le meulage génèrent  
des étincelles et des particules métalliques vo-  
Tenir les bouteilles éloignées des circuits de soudage ou autres circuits  
électriques.  
D
D
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
lantes. Pendant la période de refroidissement des soudures, elles ris-  
quent de projeter du laitier.  
Une électrode de soudage ne doit jamais entrer en contact avec une bou-  
teille.  
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.  
D
D
Ne jamais souder une bouteille pressurisée risque dexplosion.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et  
raccords convenables pour cette application spécifique; les maintenir ainsi  
que les éléments associés en bon état.  
LES ACCUMULATIONS DE GAZ ris-  
quent de provoquer des blessures ou  
même la mort.  
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille.  
Maintenir le chapeau de protection sur la soupape, sauf en cas dutilisation  
ou de branchement de la bouteille.  
D
Fermer lalimentation du gaz protecteur en cas de  
non utilisation.  
D
Lire et suivre les instructions concernant les bouteilles de gaz comprimé,  
les équipements associés et les publication P-1 CGA énumérées dans les  
normes de sécurité.  
D
Veiller toujours à bien aérer les espaces confinés ou se servir dun respi-  
rateur dadduction dair homologué.  
1-3. Dangers existant en relation avec le moteur  
LE CARBURANT MOTEUR peut provo-  
quer un incendie ou une explosion.  
LA VAPEUR ET LE LIQUIDE DE  
REFROIDISSEMENT CHAUD peuvent  
provoquer des brûlures.  
D
D
Arrêter le moteur avant de vérifier le niveau de carbu-  
rant ou de faire le plein.  
D
Il est préférable de vérifier le liquide de  
refroidissement une fois le moteur refroidi pour éviter  
de se brûler.  
Ne pas faire le plein en fumant ou proche dune sour-  
ce d’étincelles ou dune flamme nue.  
D
D
D
Ne pas faire le plein de carburant à ras bord; prévoir de lespace pour son  
expansion.  
D
Toujours vérifier le niveau de liquide de refroidissement dans le vase  
dexpansion (si présent), et non dans le radiateur (sauf si précisé autre-  
ment dans la section maintenance du manuel du moteur).  
Faire attention de ne pas renverser de carburant. Nettoyer tout carbu-  
rant renversé avant de faire démarrer le moteur.  
D
D
D
Si le moteur est chaud et que le liquide doit être vérifié, opérer comme  
suivant :  
Jeter les chiffons dans un récipient ignifuge.  
Mettre des lunettes de sécurité et des gants, placer un torchon sur le  
bouchon du radiateur.  
Dévisser le bouchon légèrement et laisser la vapeur s’échapper avant  
denlever le bouchon.  
OM-477 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
LACIDE DE LA BATTERIE peut pro-  
voquer des brûlures dans les YEUX et  
sur la PEAU.  
D
Ne pas approcher les mains des ventilateurs, cour-  
roies et autres pièces en mouvement.  
D
D
D
Ne pas renverser la batterie.  
D
Maintenir fermés et fixement en place les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
Remplacer une batterie endommagée.  
Rincer immédiatement les yeux et la peau à leau.  
D
D
Arrêter le moteur avant dinstaller ou brancher lappareil.  
Demander seulement à un personnel qualifié denlever les dispositifs de  
sécurité ou les recouvrements pour effectuer, sil y a lieu, des travaux  
dentretien et de dépannage.  
LES GAZ D’ÈCHAPPEMENT DU  
MOTEUR peuvent provoquer des  
accidents mortels.  
D
D
D
Pour empêcher tout démarrage accidentel pendant les travaux dentre-  
tien, débrancher le câble négatif () de batterie de la borne.  
Ne pas approcher les mains, cheveux, vêtements lâches et outils des or-  
ganes mobiles.  
D
Utiliser l’équipement à lextérieur dans des zones ou-  
Remettre en place les panneaux ou les dipositifs de protection et fermer  
les portes à la fin des travaux dentretien et avant de faire démarrer le  
moteur.  
vertes et bien ventilées.  
D
En cas dutilisation dans un endroit fermé évacuer les gaz d’échappe-  
ment du moteur vers lextérieur à distance des entrées dair dans les bâti-  
ments.  
D
D
Avant dintervenir, déposer les bougies ou injecteurs pour éviter la mise  
en route accidentelle du moteur.  
Bloquer le volant moteur pour éviter sa rotation lors dune intervention  
sur le générateur.  
LA CHALEUR DU MOTEUR peut pro-  
voquer un incendie.  
LEXPLOSION DE LA BATTERIE peut  
RENDRE AVEUGLE.  
D
Ne pas placer lappareil sur, au-dessus ou à proximité  
de surfaces inflammables.  
D
Toujours porter une protection faciale, des gants en  
caoutchouc et vêtements de protection lors dune in-  
tervention sur la batterie.  
D
Tenir  
à
distance les produits inflammables de  
l’échappement.  
D
D
D
Arrêter le moteur avant de débrancher ou de brancher les câbles de  
batterie.  
LES ÉTINCELLES À L’ÉCHAPPEMENT  
peuvent provoquer un incendie.  
Eviter de provoquer des étincelles avec les outils en travaillant sur la  
batterie.  
Ne pas utiliser le poste de soudage pour charger les batteries ou des vé-  
hicules de démarrage rapide.  
D
D
Empêcher les étincelles d’échappement du moteur  
de provoquer un incendie.  
D
D
Observer la polarité correcte (+ et ) sur les batteries.  
Utiliser uniquement un pare-étincelles approuvé –  
Débrancher le câble négatif () en premier lieu. Le rebrancher en dernier  
lieu.  
voir codes en vigueur.  
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance  
LA CHUTE DE LAPPAREIL peut  
blesser.  
LEMPLOI EXCESSIF peut  
SURCHAUFFER L’ÉQUIPEMENT.  
D
D
Utiliser lanneau de levage uniquement pour soulever  
lappareil lui-même ; sans chariot, de bouteilles de  
gaz, remorque, ou autres accessoires.  
D
D
D
Laisser l’équipement refroidir ; respecter le facteur de  
marche nominal.  
Réduire le courant ou le facteur de marche avant de  
poursuivre le soudage.  
Utiliser un équipement de levage de capacité suffi-  
sante pour lever lappareil.  
Ne pas obstruer les passages dair du poste.  
D
En utilisant des fourches de levage pour déplacer lunité, sassurer  
que les fourches sont suffisamment longues pour dépasser du côté  
opposé de lappareil.  
LES  
CHARGES  
peuvent  
ÉLECTROSTATIQUES  
LES ÉTINCELLES VOLANTES ris-  
quent de provoquer des blessures.  
endommager les circuits imprimés.  
D
Établir la connexion avec la barrette de terre avant de  
manipuler des cartes ou des pièces.  
D
Porter un écran facial pour protéger le visage et les  
yeux.  
D
Utiliser des pochettes et des boîtes antistatiques  
pour stocker, déplacer ou expédier des cartes de  
circuits imprimes.  
D
D
Affuterr l’électrode au tungstène uniquement à la meuleuse dotée de pro-  
tecteurs. Cette manoeuvre est à exécuter dans un endroit sûr lorsque  
lon porte l’équipement homologué de protection du visage, des mains et  
du corps.  
UNE REMORQUE QUI BASCULE peut  
entraîner des blessures.  
Les étincelles risquent de causer un incendie – éloigner toute substance  
inflammable.  
D
D
Utiliser les supports de la remorque ou des blocs  
pour soutenir le poids.  
LE SURCHAUFFEMENT peut endom-  
mager le moteur électrique.  
Installer convenablement le poste sur la remorque  
comme indiqué dans le manuel sy rapportant.  
D
Arrêter ou déconnecter l’équipement avant de dé-  
marrer ou darrêter le moteur.  
LIRE LES INSTRUCTIONS.  
D
Ne pas laisser tourner le moteur trop lentement sous  
risque dendommager le moteur électrique à cause  
dune tension et dune fréquence trop faibles.  
D
D
Utiliser seulement les pièces de rechange dorigine.  
Effecteur la maintenance et la mise en service  
D
Ne pas brancher de moteur de 50 ou de 60 Hz à la prise de 100 Hz, sil y a  
daprès le manuel et celui du moteur.  
lieu.  
OM-477 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
LE SOUDAGE À LARC risque de  
provoquer des interférences.  
D
L’énergie électromagnétique risque de provoquer  
des interférences pour l’équipement électronique  
sensible tel que les ordinateurs et l’équipement com-  
mandé par ordinateur tel que les robots.  
D
Le rayonnement haute fréquence (H.F.) peut  
provoquer des interférences avec les équipements  
de radionavigation et de communication, les  
services de sécurité et les ordinateurs.  
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit compatible  
électromagnétiquement.  
D
D
Demander seulement à des personnes qualifiées familiarisées avec des  
équipements électroniques de faire fonctionner linstallation.  
Pour réduire la possibilité dinterférence, maintenir les câbles de souda-  
ge aussi courts que possible, les grouper, et les poser aussi bas que pos-  
sible (ex. par terre).  
Lutilisateur est tenu de faire corriger rapidement par un électricien quali-  
fié les interférences résultant de linstallation.  
D
D
D
Veiller à souder à une distance de 100 mètres de tout équipement élec-  
tronique sensible.  
D
D
D
Si le FCC signale des interférences, arrêter immédiatement lappareil.  
Effectuer régulièrement le contrôle et lentretien de linstallation.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre conformé-  
ment à ce mode demploi.  
Maintenir soigneusement fermés les portes et les panneaux des sources  
de haute fréquence, maintenir les éclateurs à une distance correcte et  
utiliser une terre et et un blindage pour réduire les interférences  
éventuelles.  
En cas dinterférences après avoir pris les mesures précédentes, il in-  
combe à lutilisateur de prendre des mesures supplémentaires telles que  
le déplacement du poste, lutilisation de câbles blindés, lutilisation de fil-  
tres de ligne ou la pose de protecteurs dans la zone de travail.  
1-5. Principales normes de sécurité  
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Weld-  
ing Society, 550 N.W. Lejeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de la Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent  
of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Règles de sécurité en soudage, coupage et procédés connexes, norme  
CSA W117.2, de lAssociation canadienne de normalisation, vente de  
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.  
RecommendedSafe Practice for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, norme AWS  
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL  
33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,  
1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting and Welding Processes, norme NFPA 51B, de la National Fire  
Protection Association, Batterymarch Park, Quincy, MA 02269.  
1-6. Information sur les champs électromagnétiques  
Données sur le soudage électrique et sur les effets, pour lorganisme,  
des champs magnétiques basse fréquence  
Afin de réduire les champs électromagnétiques dans lenvironnement  
de travail, respecter les consignes suivantes :  
1
Garder les câbles ensembles en les torsadant ou en les  
attachant avec du ruban adhésif.  
Le courant de soudage, pendant son passage dans les câbles de sou-  
dage, causera des champs électromagnétiques. Il y a eu et il y a encore  
un certain souci à propos de tels champs. Cependant, après avoir ex-  
aminé plus de 500 études qui ont été faites pendant une période de  
recherche de 17 ans, un comité spécial ruban bleu du National Re-  
search Council a conclu: Laccumulation de preuves, suivant le  
jugement du comité, na pas démontré que lexposition aux champs  
magnétiqueset champs électriques à haute fréquence représente un  
risque à la santé humaine. Toutefois, des études sont toujours en cours  
et les preuves continuent à être examinées. En attendant que les con-  
clusions finales de la recherche soient établies, il vous serait  
souhaitablede réduire votre exposition aux champs électromagnéti-  
ques pendant le soudage ou le coupage.  
2
3
Mettre tous les câbles du côté opposé de lopérateur.  
Ne pas courber pas et ne pas entourer pas les câbles autour de  
votre corps.  
4
5
Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
Relier la pince de masse le plus près possible de la zone de  
soudure.  
Consignes relatives aux stimulateurs cardiaques :  
Les personnes qui portent un stimulateur cardiaque doivent avant tout  
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est  
alors recommandé de respecter les consignes cidessus.  
OM-477 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2 DEFINITIONS  
2-1. Symbols And Definitions  
Fast (Run, Weld/  
Power)  
Stop Engine  
Slow (Idle)  
Output  
Start Engine  
Engine Oil  
Fast/Slow  
(Run/Idle)  
Battery (Engine)  
Check Valve  
Clearance  
Protective Earth  
(Ground)  
Circuit Breaker  
Positive  
Fuel  
Certified/Trained  
Mechanic  
Negative  
Welding Arc  
Remote 14  
Amperes  
Volts  
Panel/Local  
Temperature  
14  
A V  
Read Operators  
Engine Coolant  
Temperature  
G
Engine  
1
Manual  
Alternating  
Current  
Time  
Hours  
Seconds  
h
s
Stick Welding  
(SMAW)  
Constant Current  
(CC)  
MIG Welding  
(GMAW)  
Constant Voltage  
(CV)  
Do Not Switch  
While Welding  
Single Phase  
Three Phase  
1
3
SECTION 3 SPECIFICATIONS  
3-1. Weld, Power, And Engine Specifications  
Maximum  
Open-Circuit  
Voltage  
Welding  
Mode  
Weld Output  
Range  
Rated Welding  
Output  
Auxiliary Power  
Rating  
Engine  
Fuel Capacity  
375 A, 35 Volts DC,  
50% Duty Cycle  
Teledyne-Continental  
TM-20 Water-Cooled,  
Three-Cylinder,  
38 HP Gasoline  
Engine  
CC/DC  
50 440 A  
95  
40  
Single-Phase,  
3 kVA/kW, 26 A,  
120 V AC, 60 Hz  
300 A, 32 Volts DC  
100% Duty Cycle  
16 gal (60.6 L)  
CV/DC  
(Optional)  
300 A, 32 Volts DC,  
100% Duty Cycle  
14 38 V  
OM-477 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-2. Dimensions, Weights, And Operating Angles  
Dimensions  
Height  
48-3/4 in (1238 mm)  
24-5/8 in (625 mm)  
64-1/2 (1638 mm)  
62 in (1575 mm)  
Width  
Engine End  
L
Depth  
Y
Y
Do not exceed tilt angles or engine could  
be damaged or unit could tip.  
A
B
C
D
E
F
Do not move or operate unit where it could  
tip.  
59-1/8 in (1502 mm)  
46-1/4 in (1175 mm)  
34-3/4 in (883 mm)  
26-15/16in (684) mm)  
9-1/2 in (241 mm)  
2-7/8 in (73 mm)  
B
A
C
33°  
E
G
H
J
D
33°  
20°  
20°  
7/8 in (22 mm)  
G
H
F
23-1/4 in (591 mm)  
24-5/8 in (625 mm)  
J
K
K
21/32 in  
(16.7 mm) Dia.  
12 Holes  
L
ST-154 859  
angles_1 8/99  
Weight  
1390 lb (631 kg)  
3-3. Fuel Consumption  
The curve shows typical fuel use  
under weld or power loads.  
SB-114 553-A  
OM-477 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-4. Duty Cycle And Overheating  
Duty Cycle is percentage of 10 min-  
utes that unit can weld at rated load  
without overheating.  
Y
Exceeding duty cycle can  
damage unit and void  
warranty.  
60% Duty Cycle At 350 Amperes  
100% Duty Cycle At 300 Amperes  
6 Minutes Welding  
4 Minutes Resting  
Continuous Welding  
rduty1 5/95 SB-111 076-A  
3-5. AC Auxiliary Power  
The ac power curve shows the aux-  
iliary power in amperes available at  
the 120 and 240 volt receptacles.  
rsb3.1 2/92 ST-109 365-C  
OM-477 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-6. Optional AC Power Plant Curves  
The ac power curves show the aux-  
iliary power in amperes available at  
the single-phase 120/240 volt or  
three-phase240 volt terminals.  
A. 8.5 KVA/KW Single-Phase Auxiliary Power Plant  
(No Weld Load)  
280  
260  
240  
220  
200  
180  
0
20  
40  
60  
80  
100  
AC AMPERES  
B. 12.5 KVA/KW Three-Phase Auxiliary Power Plant  
(No Weld Load)  
280  
260  
240  
220  
200  
180  
0
10  
20  
30  
40  
50  
60  
70  
AC AMPERES  
rsb13.1 12/94 - ST-111 118-D / ST-112 449-B  
OM-477 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-7. Volt-Ampere Curves  
The volt-ampere curve shows the  
minimum and maximum voltage  
and amperage output capabilities of  
the welding generator. Curves of all  
other settings fall between the  
curves shown.  
A. CC/DC (Standard)  
100  
Ranges: 190Max  
110270  
80  
60  
40  
20  
0
85210  
55110  
Min65  
0
100  
200  
300  
500  
600  
700  
400  
DC Amperes  
B. CC/AC (Models with Optional Polarity/AC Selector Switch)  
100  
80  
60  
40  
20  
0
0
100  
200  
300  
400  
500  
600  
700  
AC Amperes  
C. CV/DC (Models with Optional CV-3 Module)  
rsb13.1 12/94 ST-184 477-A / ST-184 475-A / ST-184 480-A  
OM-477 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4 INSTALLATION  
4-1. Installing Welding Generator  
Movement  
Airflow Clearance  
Location  
18 in  
(460 mm)  
Y
Do Not Lift Unit From End  
18 in  
(460 mm)  
18 in  
(460 mm)  
OR  
OR  
18 in  
(460 mm)  
18 in  
(460 mm)  
Grounding  
3
Y
Always ground generator frame to ve-  
hicle frame to prevent electric shock  
and static electricity hazards.  
1
4
GND/PE  
1
2
3
4
Generator Base  
Metal Vehicle Frame  
Equipment Grounding Terminal  
Grounding Cable  
OR  
Use #10 AWG or larger insulated copper wire.  
Electrically bond generator frame to  
vehicle frame by metal-to-metal  
contact.  
Y
If unit does not have GFCI receptacles,  
use GFCI-protected extension cord.  
2
2
install1 12/99 Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854  
4-2. Connecting The Battery  
Tools Needed:  
1/2 in  
Y
Connect  
Negative ()  
Cable Last  
+
Ref. ST-138 751-B / Ref. ST-191 898 / Ref. S-0756-C  
4-3. Installing Muffler  
Y
Y
Stop engine and let cool.  
Do not blow exhaust toward  
air cleaner or air intake.  
Tools Needed:  
1/2 in  
muff1 4/96 ST-154 088-B / Ref. ST-191 898  
OM-477 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-4. Engine Prestart Checks  
Check all fluids daily. Engine must  
be cold and on a level surface.  
. This unit has a low oil pressure  
shutdown switch. However,  
some conditions may cause  
engine damage before the en-  
gine shuts down. Check oil lev-  
el often and do not use the oil  
pressure shutdown system to  
monitor oil level.  
1/2 in  
(13 mm)  
Full  
Gasoline  
Full  
1
2
Carburetor Heat Selector Pipe  
Manifold  
Turn pipe toward manifold in cold  
weather and away from manifold in  
warm weather.  
Capacity:  
9 qt (8.5 L)  
3
Fuel  
Add fresh fuel before starting  
engine the first time (see mainte-  
nance label for specifications). Fill  
fuel tank up to 1/2 in. (13 mm) from  
top to allow room for expansion.  
Open fuel shut-off valve. Check fuel  
level on a cold engine before use  
each day.  
4
Oil  
After fueling, check oil with unit on  
level surface. If oil is not up to full  
mark on dipstick, add oil (see main-  
tenance label).  
5
Coolant  
Add coolant if level is below bottom  
of radiator filler neck.  
Engine coolant is a mixture of water  
and ethylene glycol base anti-  
freeze. Add anti-freeze to mixture if  
using unit in temperatures below 0°  
F (18° C).  
Keep radiator, air intake, and cool-  
ing fins clean and free of dirt.  
Y
Incorrect engine tempera-  
ture can damage engine. Do  
not run engine without a  
properly working 180°F  
(80°C) thermostat and a 7 psi  
(48 kPa) radiator cap.  
Full  
.
T
o
i
m
p
r
o
v
e
c
o
l
d
w
e
a
t
h
e
r
starting:  
Keep battery in good condition.  
Store battery in warm area off  
concrete surface.  
Top View  
2
1
Use correct grade oil for cold  
weather.  
Above  
40°F (4°C)  
Below  
40°F (4°C)  
Tools Needed:  
5/16 in  
ST-801 026-A / Ref. ST-159 727-C / Ref. ST-159 728-A  
OM-477 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-5. Connecting To Weld Output Terminals  
Open left side door.  
Bracket  
Route cables through bracket.  
1
3
2
Positive (+) Weld Output  
Terminal  
2
3
Negative () Weld Output Ter-  
minal  
For Stick welding Direct Current  
Electrode Positive (DCEP), con-  
nect work cable to () terminal and  
electrode holder cable to (+)  
terminal.  
For Direct Current Electrode Nega-  
tive (DCEN), reverse cable  
connections.  
Left Side  
If equipped with optional polarity  
switch, connect electrode holder  
cable to Electrode () terminal and  
work cable to Work (+) terminal.  
For MIG and FCAW welding with  
CV option, connect work cable to  
() terminal and wire feeder cable to  
(+) terminal  
Close door.  
1
Tools Needed:  
3/4 in  
ST-800 162-A  
4-6. Selecting Weld Cable Sizes  
Total Cable (Copper) Length In Weld Circuit Not Exceeding  
150 ft  
(45 m)  
200 ft  
(60 m)  
250 ft  
(70 m)  
300 ft  
(90 m)  
350 ft  
(105 m)  
400 ft  
(120 m)  
100 ft (30 m) Or Less  
10 60% 60 100% Duty  
Welding  
Amperes  
10 100% Duty Cycle  
Duty Cycle  
Cycle  
100  
150  
200  
250  
300  
350  
400  
500  
4
3
4
4
3
1
2
1
1/0  
3/0  
1/0  
3/0  
3
2
1/0  
2/0  
3
2
1
1/0  
2/0  
3/0  
4/0  
4/0  
2-2/0  
2/0  
3/0  
4/0  
4/0  
2
1
1/0  
2/0  
3/0  
3/0  
4/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
3-3/0  
2-2/0  
2-3/0  
2-4/0  
2-4/0  
3-3/0  
1
1/0  
2/0  
2/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
1/0  
1/0  
2/0  
2-2/0  
2-2/0  
2-3/0  
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your  
2
distributor for the mm equivalent weld cable sizes.  
S-0007-E  
OM-477 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-7. Remote 14 Receptacle RC3 Information (Optional, See Section 4-8)  
Socket*  
Socket Information  
A
24 volts ac. Protected by circuit  
breaker CB4.  
B
I
Contact closure to A completes 24  
volts ac contactor control circuit.  
115 volts ac. Protected by circuit  
breaker CB3.  
A
J
K
I
B
C
J
Contact closure to I completes 115  
volts ac contactor control circuit.  
L
N
H
M
D
G
G
C
Circuit common for 24 and 115 volts ac  
circuits.  
F
E
0 to +10 volts dc output to remote  
control.  
D
E
Remote control circuit common.  
A/V  
0 to +10 volts dc input command signal  
from remote control.  
Ref. ST-159 730-A  
K
Chassis common.  
*The remaining sockets are not used.  
4-8. Terminal Strip 3T Connections (Optional)  
Y
Stop engine.  
If remote control plug does not fit in  
receptacle RC3, wire cord directly  
to terminal strip 3T.  
Y
Do not connect to Remote 14  
receptacleRC3 and terminal  
strip 3T at the same time. Use  
only one remote control  
method.  
Open right side door.  
1
2
Cover  
Terminal Strip 3T  
Connect leads to 3T using terminal  
information shown in Section 4-7.  
Reinstall cover. Close door.  
2
1
Tools Needed:  
Ref. ST-139 670-B / ST-185 316 / Ref. ST-191 898  
OM-477 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5 OPERATING WELDING GENERATOR  
5-1. Front Panel Controls (See Section 5-2)  
3
4
5
1
2
6
7
17  
16  
15  
14  
13  
11  
10  
9
8
()  
12  
Ref. ST-159 730-A / Ref. ST-191 898  
OM-477 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2. Description Of Front Panel Controls (See Section 5-1)  
nected to receptacle RC3 or terminal strip 3T In Run position, engine runs at weld/power  
.
T
h
i
s
u
n
i
t
h
a
s
a
m
a
x
O
C
V
c
o
n
t
r
o
l
c
i
r
c
u
i
t
(see Sections 4-7 and 4-8).  
speed. In Run/Idle position, engine runs at idle  
speed at no load and weld speed with load ap-  
plied. Turn to run position if using optional aux-  
iliary power plant.  
that resets Amperage/Voltage Adjust  
Control R1 to maximum when the arc  
breaks. When an arc is struck, weld out-  
put control returns to the R1 front panel or  
combination front panel/remote control  
setting. The Amperage/Voltage Adjust  
control adjusts amperage only when  
constant current (CC) welding and does  
not adjust open-circuit voltage. The max  
OCV control circuit does not function  
when constant voltage (CV) welding  
(optional).  
Y
Weld output terminals are energized  
when Output (Electrode) switch is On  
(Hot) and engine is running.  
To Start: Pull choke out. Turn Engine Control  
switch to Start while pressing Shutdown  
switch. Release Engine Control switch when  
engine starts, then release Shutdown switch  
and push choke in.  
For weld output, place switch in the On (Hot)  
position. Open-circuit voltage is present at the  
weld output terminals whenever engine is run-  
ning.  
For remote output control, place switch in Re-  
mote position. Open-circuit voltage is present  
at the weld output terminals when remote con-  
tactor switch is closed.  
. If the engine does not start, let engine  
come to a complete stop before attempt-  
ing restart.  
1
Ampere Range Switch  
5
Process Switch (Optional)  
To Stop: turn Engine Control switch to Off  
Y
Do not switch under load.  
position.  
Use switch to select Stick or MIG (CV) weld  
output. Use Stick for Stick (SMAW) welding.  
Use MIG (CV) for wire feed processes (MIG,  
FCAW). If using MIG (CV), place Ampere  
Range switch in maximum position. To en-  
sure wire feeder reliability and improve arc  
starting, unit does not run at idle speed  
when operated in MIG (CV) mode.  
Use switch to select weld amperage range.  
For most welding applications, use lowest am-  
perage range possible to help prevent arc out-  
ages. When using MIG (CV) mode (optional),  
place switch in maximum position.  
11 Engine Hour Meter  
12 Polarity And AC Selector Switch  
(Optional)  
Y
Do not switch under load.  
2
Amperage/Voltage Adjust Control  
13 Battery Charging Warning Light  
Light goes on if battery is not charging.  
Control adjusts amperage within range se-  
lected by Ampere Range switch. Weld output . Place Process switch in Stick position  
14 Low Oil Pressure/High Engine Tempera-  
ture Warning Light  
would be 148 A DC with controls set as shown  
(50% of 85 to 210 A).  
when using optional auxiliary power plant.  
6
7
8
DC Voltmeter (Optional)  
Light goes on if oil pressure is low or coolant  
temperature is high.  
3
Amperage/Voltage Adjust Switch  
(Optional)  
DC Ammeter (Optional)  
Y
Stop engine and fix trouble if either  
warning light goes on.  
Magnetic Shutdown Switch  
Use switch to select front panel or remote am-  
perage control (see Section 5-3).  
Use switch during start-up to bypass engine  
shutdown system. System stops engine if oil  
pressure is too low or coolant temperature is  
too high.  
15 Fuel Gauge  
For front panel control, place switch in Panel  
position. For remote control, place switch in  
Remote position and connect remote control  
to Remote 14 receptacle RC3 or terminal strip  
3T.  
16 Engine Temperature Gauge (Optional)  
Normal temperature is 180 - 200° F (81 - 93°  
C). Stop engine if temperature exceeds 240°  
F (116° C).  
9
Choke Control  
Use choke to change engine air-fuel mix.  
10 Engine Control Switch  
4
Output (Electrode) Control Switch  
(Optional)  
17 Engine Oil Pressure Gauge (Optional)  
Use switch to start engine, select engine Normal pressure is 40 psi (276 kPa). Stop en-  
gine if pressure is below 8 psi (55 kPa).  
Use switch to control remote contactor con- speed, and stop engine.  
OM-477 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-3. Remote Control (Optional)  
Y
Weld output terminals are  
energized when Output  
(Electrode) switch is On  
(Hot) and engine is running.  
1
Remote 14 Receptacle RC3  
Connect optional remote control to  
RC3 (see Section 4-7).  
1
Example: Combination remote amperage control  
In Example:  
Range = 85 to 210 A DC  
Min = 85 A DC  
Percentage of Range = 50%  
Max = 148 A DC (50% of 85 to 210)  
OR  
Max (148 A DC)  
Min (85 A DC)  
Set switches  
Set range  
Set percentage  
Adjust optional remote control  
S-0774 / Ref. ST-159 730-A / Ref. ST-191 898  
OM-477 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6 OPERATING AUXILIARY EQUIPMENT  
6-1. 120 Volt Duplex And Optional GFCI Receptacles  
Y
If unit does not have GFCI re-  
ceptacles, use GFCI-pro-  
tected extension cord.  
1
2
3
120 V 15 A AC Receptacle  
RC1  
120 V 15 A AC Receptacle  
RC2  
120 V 15 A AC GFCI Recep-  
tacles GFCI1 And GFCI2  
(Optional)  
1
2
Receptacles supply 60 Hz single-  
phase power at weld/power speed.  
4
5
Circuit Breaker CB1  
Circuit Breaker CB2  
4
5
CB1 protects RC1/GFCI1 and CB2  
protects RC2/GFCI2 from over-  
load. If CB1 or CB2 opens, the re-  
ceptacle does not work. Press but-  
ton to reset circuit breaker.  
.
I
f
a
c
i
r
c
u
i
t
b
r
e
a
k
e
r
c
o
n
t
i
n
u
e
s
t
o
open, contact  
a
Factory  
Authorized Service Agent.  
If a ground fault is detected, the  
GFCI Reset button pops out and  
the circuit opens to disconnect the  
faulty equipment. Check for dam-  
aged tools, cords, plugs, etc. con-  
nected to the receptacle. Press but-  
ton to reset receptacle and resume  
operation.  
. At least once a month, run en-  
gine at weld/power speed and  
press Test button to verify  
GFCI is working properly.  
Maximum output from each duplex  
receptacle is 1.8 kVA/kW, and 3  
kVA/kW from all receptacles.  
Auxiliary power is not affected by  
weld output.  
EXAMPLE: If 15 A is drawn from  
RC1, only 10 A is available at RC2:  
(120 V x 15 A) + (120 V x 10 A) = 3.0  
kVA/kW  
3
Ref. ST-191 898  
OM-477 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-2. 240 Volt Duplex Receptacle (Optional)  
Y
If unit does not have GFCI re-  
ceptacles, use GFCI-pro-  
tected extension cord.  
1
240 V 15 A AC Receptacle  
RC1  
Receptacle supplies 60 Hz single-  
phase power at weld/power speed.  
Maximum output is 3 kVA/kW.  
1
2
3
Circuit Breaker CB1  
Circuit Breaker CB2  
CB1 and CB2 protect the recep-  
tacles from overload. If CB1 or CB2  
opens, the 240 V receptacle and  
half of the 120 V receptacle does  
not work. 120 volts may still be  
present at the 240 V receptacle.  
Press button to reset circuit  
breaker.  
2
3
.
I
f
a
c
i
r
c
u
i
t
b
r
e
a
k
e
r
c
o
n
t
i
n
u
e
s
t
o
open, contact  
a
Factory  
Authorized Service Agent.  
Combined output of all receptacles  
is 3 kVA/kW. Auxiliary power is not  
affected by weld output.  
EXAMPLE:If 10 A is drawn from the  
240 V receptacle, only 5 A is avail-  
able at the 120 V receptacle:  
(240 V x 10 A) + (120 V x 5 A) = 3.0  
kVA/kW  
Ref. ST-181 711-A / Ref. ST-174 408  
OM-477 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-3. Connecting Optional Auxiliary Power Plant  
Y
Y
Stop engine.  
Power and weld outputs are  
live at the same time. Discon-  
nect or insulate unused  
cables.  
. Have qualified person install ac-  
cording to circuit diagram and  
Auxiliary Power Guidelines  
Booklet (M176 712).  
. Place optional Process switch  
in Stick position when using op-  
tional auxiliary power plant.  
Front  
Remove junction box cover.  
11  
10  
1
2
3
4
5
6
7
8
Lead 93  
Lead 92  
Lead 91  
Lead 90 (Neutral)  
Isolated Neutral Terminal  
Jumper Lead 42  
Grounding Terminal  
1
2
F3  
F2  
F1  
240V  
240V  
240V 240V  
3
Lead 42 (Circuit Grounding  
Lead)  
120V 120V  
1
Jumper 42 is connected to lead 90 at  
factory. Jumper 42 may be discon-  
nected from neutral to meet applica-  
ble electrical codes.  
3
9
Lead 42 connects to front panel  
Ground stud.  
9
User-Supplied Leads  
10 Load Terminals  
4
5
6
7
8
Connect leads to terminals.  
11 Fuses F1, F2, And F3  
F1, F2, and F3 protect each load line  
from overload.  
. Set Engine Control switch to  
Run when using auxiliary  
power.  
Single  
Phase  
1
Three  
Phase  
3
AC  
Output  
Volts  
120/240  
240  
93  
91  
Amps  
35  
30  
KVA/KW  
Frequency  
8.5  
12.5  
60 Hz  
Engine Speed  
1850 RPM  
Max. Fuse Size  
45 Amperes  
90  
92  
Lead 42 connects to GROUND stud on  
front of unit.  
Jumper 42 is connected to 90 at factory.  
Tools Needed:  
Ref. S-185 000A  
OM-477 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 MAINTENANCE AND TROUBLESHOOTING  
Follow the storage procedure in the engine owners manual if the unit will not be  
used for an extended period.  
NOTE  
7-1. Routine Maintenance  
Y
Stop engine before maintaining.  
Recycle  
engine  
fluids.  
.
S
e
e
a
l
s
o
E
n
g
i
n
e
M
a
n
u
a
l
a
n
d
M
a
i
n
t
e
n
a
n
c
e
Label. Service engine more often if used in  
severe conditions.  
*
To be done by Factory Authorized Service  
Agent.  
8 h  
Wipe up spills.  
Check fluid levels.  
See Section 4-4.  
OIL  
Full  
50 h  
Clean air filter.  
See Section 7-3.  
Clean and tighten  
weld terminals.  
100 h  
Check  
air  
Change oil. See  
Section 7-5.  
Change oil filter.  
See Section 7-5.  
cleaner hoses  
for cracks and  
loose clamps.  
Replace fuel filter.  
See Section 7-6.  
Clean and tighten battery  
connections.  
200 h  
250 h  
Replace  
unreadable  
labels.  
Check spark  
plugs.  
Check and clean  
spark arrestor.  
See Section 7-7.  
500 h  
Check valve clearance.*  
Repair or replace  
cracked cables.  
1000 h  
Blow out or  
vacuum inside.  
During heavy  
service, clean  
monthly.  
Service welding generator  
brushes and slip rings.  
Service more often in dirty  
conditions.*  
Check  
belt  
tension.  
1/2 in.  
(13 mm)  
Or  
OM-477 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-2. Maintenance Label  
OM-477 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-3. Servicing Air Cleaner  
Y
Y
Stop engine.  
Do not run engine without air  
cleaner or with dirty element.  
Clean or replace element if dirty or  
damaged. Replace element yearly  
or after six cleanings.  
1
2
3
4
5
Dust Cap  
Baffle  
5
4
3
2
1
Element  
Plastic Fins  
Housing  
To Clean air filter:  
Wipe off cap and housing. Remove  
cap and dump out dust. Wipe dust  
from inside cap and housing with  
damp cloth. Remove element and  
reinstall cap.  
Y
Do not clean housing with air  
hose.  
Clean element with compressed air  
only. Keep nozzle at least 1 in (25  
mm) from inside of element. Max. air  
pressure: 100 psi (690 kPa). Do not  
remove plastic fins. Replace ele-  
ment if it has holes or damaged  
gaskets.  
Reinstall element and cap (cap  
arrows pointing up).  
Blow  
Inspect  
aircleaner1 6/96 ST-153 929-B / ST-153 585 / Ref. ST-191 898 / Ref. S-0698-B  
7-4. Overload Protection  
Y
Stop engine.  
. If any fuse or circuit breaker  
continues to open, contact Fac-  
tory Authorized Service Agent.  
1
Magnetic Shutdown  
Switch MS1  
2
Fuse F (See Parts List)  
Fuse F protects magnetic shutdown  
switch MS1. If fuse F opens, the  
engine stops.  
Check fuse and replace if open.  
3
4
Circuit Breaker CB3 (Optional)  
Circuit Breaker CB4 (Optional)  
CB3 protects the 115 volt ac output  
and CB4 protects the 24 volt ac out-  
put to optional Remote 14 recep-  
tacle RC3 and terminal strip 3T. If a  
circuit breaker opens, 24 or 115  
volts ac output stops.  
1
3
4
Press button to reset breaker.  
2
Tools Needed:  
Ref. ST-159 730-A / Ref. ST-191 898  
OM-477 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-5. Changing Engine Oil And Filter  
Y
1
Stop engine and let cool.  
Standard Oil Filter  
2
Optional Remote Oil Filter  
3
Optional Remote Oil Filter  
Hoses And Adapter  
4
5
Oil Drain Plug  
Oil Fill Cap  
Change filter according to engine  
manual.  
Install optional remote oil filter if lo-  
cation makes it difficult to change  
standard filter.  
1
. The remote oil filter requires  
extra oil to fill the hoses. Keep  
oil up to full mark on dipstick.  
4
5
3
Tools Needed:  
2
7/8 in  
Ref. ST-159 727-B / Ref. ST-159 728-A / Ref. ST-191 898  
OM-477 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-6. Changing Fuel Filter  
Y
1
Stop engine and let cool.  
Fuel Shutoff Valve  
Fuel Line  
2
3
Fuel Filter  
To replace filter, close valve and re-  
move clamps and filter. Install new  
filter and clamps. Inspect line and  
replace if cracked or worn. Wipe up  
any spilled fuel. Open valve.  
Start engine and check for leaks.  
Y
Stop engine, tighten connec-  
tions as necessary, and wipe  
up spilled fuel.  
Close door.  
1
2
3
2
Tools Needed:  
Ref. ST-191 898 / Ref. ST-159 727-C  
7-7. Inspecting And Cleaning Optional Spark Arrestor Muffler  
Y
1
Stop engine and let cool.  
Spark Arrestor Muffler  
Cleanout Plug  
2
Remove plug and remove any dirt  
covering cleanout hole.  
3
Exhaust Pipe  
Start engine and run at idle speed to  
blow out cleanout hole. If nothing  
blows out of hole, briefly cover end  
of exhaust pipe with fireproof  
material.  
3
2
1
Y
Stop engine and let cool.  
Reinstall cleanout plug.  
Tools Needed:  
3/8 in  
ST-800 722 / Ref. ST-191 898  
OM-477 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-8. Adjusting Engine Weld/Power Speed  
.
G
o
v
e
r
n
o
r
s
e
n
s
i
t
i
v
i
t
y
m
a
y
r
e
-
quire adjustment if engine  
speed is adjusted (see Section  
7-10).  
1850 rpm  
(max)  
If linkage binds, loosen socket  
nuts and turn sockets until link-  
age works smoothly. Tighten  
nuts.  
After tuning engine, check engine  
no load speed with a tachometer  
(see table for no load speeds). If  
necessary, adjust speed as follows:  
7
11  
10  
1
2
3
4
5
Socket Nut  
Governor Linkage Rod  
Lock Nut  
Socket  
9
Governor Arm  
Rod length should be 3-1/4 in (83  
mm) between lock nuts. To adjust,  
remove socket from arm and loos-  
en lock nut. Turn socket to adjust  
length. Tighten nut and reattach  
socket to arm.  
1/16 in  
(1.6 mm)  
8
6
6
7
8
Carburetor  
Throttle Stop Plate  
Throttle Stop  
Clearance between plate and stop  
should be 1/16 in (1.6 mm). To ad-  
just clearance, proceed as follows:  
9
Linkage Pivot Arm  
10 Linkage Socket  
11 Lock Nut  
Remove socket at arm and loosen  
lock nut. Turn socket to adjust  
clearance. Reattach socket and  
tighten nut.  
1
4
3-1/4 in  
(83 mm)  
Start engine and run until warm.  
Turn Engine Control switch to Run  
position.  
3
2
5
12 Governor Speed Screw  
13 Lock Nut  
Loosen nut. Turn screw until engine  
runs at weld/power speed.  
Y
Stop engine.  
Close door.  
13  
12  
Tools Needed:  
3/8, 7/16 in  
Ref. ST-801 179 / Ref. ST-800 159-C / Ref. ST-800 161  
OM-477 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-9. Adjusting Engine Idle Speed  
Start engine. Place Engine Control  
Switch in Run/Idle position.  
1
2
3
4
Solenoid Bracket Screws  
Throttle Arm  
2
5
Idle Speed Screw  
Throttle Stop  
1250 rpm  
Loosen bracket screws and move  
arm so screw touches stop. Do not  
release arm. Turn idle speed screw  
to obtain 550 rpm.  
5
Idle Mixture Screw  
Turn mixture screw counterclock-  
wise until engine falters, then turn  
screw clockwise until engine runs  
smoothly.  
1
Turn idle speed screw to obtain  
1250 rpm.  
6
7
Solenoid  
Plunger  
6
Slide solenoid inside bracket so  
plungerbottoms in solenoid. If nec-  
essary, shim solenoid/bracket to  
prevent linkage from binding. Do  
not readjust idle speed screw when  
adjustingsolenoid.  
7
3
Right Side  
Tighten bracket screws. Release  
throttle arm. Recheck idle speed  
and readjust if necessary.  
Tools Needed:  
Y
Stop engine.  
Close door.  
4
1/4 in  
Ref. ST-115 155-A  
7-10. Adjusting Governor Sensitivity  
. Governor sensitivity may re-  
quire readjustment if weld  
speed is adjusted. Weld speed  
must be readjusted if sensitivity  
is adjusted.  
Be sure carburetor and link-  
ages are adjusted properly be-  
fore adjusting sensitivity.  
3
Start engine. Apply and remove  
load.  
1
2
3
Locking Nuts  
2
1
Sensitivity Adjustment Screw  
Governor Spring  
If engine is slow to pick up load or  
rpm drops under load, adjust spring  
tension as follows:  
Loosen top nut and tighten bottom  
nut to move screw down. Tighten  
nuts.  
If engine hunts with or without load,  
adjust spring tension as follows:  
Loosen bottom nut and tighten top  
nut to move screw up. Tighten nuts.  
Y
Stop engine.  
Close door.  
Tools Needed:  
1/2 in  
Ref. ST-115 155-A / Ref. ST-159 728-A  
OM-477 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-11. Adjusting Optional High Altitude Carburetor  
Y
A too lean air-fuel mixture  
can damage valves. Do not  
adjust main adjustment  
screw so air-fuel mixture is  
too lean.  
Carburetorcan be equipped with an  
adjustable main jet for operation  
above 4000 ft (1219 m). Adjust car-  
buretor as follows:  
Start engine and apply nearly full  
load to welding generator.  
1
2
Main Adjustment Screw  
Lock Nut  
Loosen nut. Turn screw in until en-  
gine falters (lean air-fuel mixture).  
Turn screw out until engine runs  
smoothly, then turn screw out an  
additional1/4 turn. Tighten nut.  
Y
Stop engine.  
1
2
Close door.  
Tools Needed:  
1/2 in  
Ref. ST-159 727-B / Ref. ST-115 155-A  
7-12. Troubleshooting  
A. Welding  
Trouble  
Remedy  
No weld output.  
Check control settings.  
Place optional Output (Electrode) Control switch in On (Hot) position, or move switch to Remote posi-  
tion and connect remote contactor to Remote 14 receptacle RC3 or terminal strip 3T (see Sections  
4-7, 4-8, and 5-1).  
Check and secure connections to optional Remote 14 receptacle RC3 or terminal strip 3T (see Sec-  
tions 4-7 and 4-8).  
Disconnect equipment from 120 volt ac receptacles during start-up.  
Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board  
PC1.  
Erratic weld output.  
Check and tighten connections inside and outside unit.  
Use dry, properly-stored electrodes.  
Remove excessive coils from weld cables.  
Be sure connection to work piece is clean and tight.  
Have Factory Authorized Service Agent check brushes and slip rings.  
OM-477 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble  
Remedy  
Low or high weld output.  
Check control settings.  
Place optional Process switch in correct position (see Section 5-1).  
Check engine weld/power speed, and adjust if necessary (see Section 7-8).  
Have Factory Authorized Service Agent check field current regulator board PC1.  
Place optional Process switch in correct position.  
Low open-circuit voltage.  
Check engine weld/power speed, and adjust if necessary (see Section 7-8).  
Have Factory Authorized Service Agent check field current regulator board PC1 and optional CV-3 regu-  
lator board PC2.  
Maximum weld output only in each am- Have Factory Authorized Service Agent check Amperage/Voltage Adjust control R1, capacitor C8,  
pere range.  
diode D9, integrated rectifier SR4, control relay CR3, field current regulator board PC1, and optional  
CV-3 regulator board PC2.  
No CV weld output (units with remote Check connections to Remote 14 receptacle RC3 and terminal strip 3T (see Sections 4-7 and 4-8).  
control or CV-3 option only).  
Repair or replace remote control device.  
Have Factory Authorized Service Agent check connector board PC5 and connections.  
Wire feeder does not work (models with Reset circuit breaker CB3 and/or CB4 (see Section 7-4).  
CV-3 option).  
Check connections to Remote 14 receptacle RC3 and terminal strip 3T (see Sections 4-7 and 4-8).  
Repair or replace wire feeder.  
No amperage control (or voltage control Place Amperage/Voltage Adjust switch in correct position.  
on models with CV-3 option).  
Check connections to Remote 14 receptacle RC3 and terminal strip 3T (see Sections 4-7 and 4-8).  
Repair or replace remote control device.  
Have Factory Authorized Service Agent check optional CV-3 regulator board PC2.  
Low CV weld output (models with CV-3 Set Ampere Range switch to highest range.  
option).  
Min or max CV weld output only (models Check position of Amperage/Voltage Adjust control and Amperage/Voltage Adjust switch.  
with CV-3 option).  
Repair or replace remote control device.  
Have Factory Authorized Service Agent check optional CV-3 regulator board PC2.  
B. Auxiliary Power  
Trouble  
Remedy  
No output at auxiliary power ac  
receptacles.  
Reset circuit breaker CB1 and/or CB2 (see Section 6-1).  
Disconnect equipment from receptacles during start-up.  
Have Factory Authorized Service Agent check brushes and slip rings.  
No or low output at optional auxiliary  
power plant.  
Place optional Output (Electrode) Control switch in On (Hot) position, or move switch to Remote posi-  
tion and connect remote contactor to Remote 14 receptacle RC3 or terminal strip 3T (see Sections  
4-7, 4-8, and 5-1).  
Place optional Amperage/Voltage Adjust switch in Panel position, or move to Remote position and  
connect remote amperage control to Remote 14 receptacle RC3 or terminal strip 3T (see Sections  
4-7, 4-8, and 5-1)  
Place optional remote amperage control in maximum position (see Section 5-3).  
Place optional Process switch in Stick position (see Section 5-1).  
Check fuses F1, F2, and F3 and replace as necessary (see Section 6-3).  
Check engine weld/power speed, and adjust if necessary (see Section 7-8).  
OM-477 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble  
Remedy  
Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board  
PC1.  
High or low voltage at auxiliary power  
ac receptacles.  
Check engine weld/power speed, and adjust if necessary (see Section 7-8).  
Have Factory Authorized Service Agent check field current resistor R3.  
High output at optional auxiliary power Check engine weld/power speed, and adjust if necessary (see Section 7-8).  
plant.  
Have Factory Authorized Service Agent check field current regulator board PC1.  
C. Engine  
Trouble  
Remedy  
Engine does not start.  
Check fuel level. Open fuel shutoff valve (see Section 4-4).  
Check battery and replace if necessary (see Section 4-2).  
Check oil and water levels. Automatic shutdown system stops engine if oil pressure gets too low or  
coolant temperature gets too high (see Section 4-4).  
Check Engine Control switch, and replace if necessary.  
Check Magnetic Shutdown switch MS1 fuse F and replace if open (see Section 7-4).  
See engine manual.  
Have Factory Authorized Service Agent check engine charging system.  
Clean battery, terminals, and posts with baking soda and water solution; rinse with clear water.  
Periodically recharge battery (approximately every 3 months).  
Replace battery (see Section 4-2).  
Battery discharges between uses.  
Have Factory Authorized Service Agent check engine charging system.  
Check Engine Control switch, and replace if necessary.  
Engine idles, but does not come up to  
weld speed.  
Have Factory Authorized Service Agent check idle module and current transformer CT1.  
Engine does not run at idle speed.  
Move Optional Process switch to Stick position (see Section 5-1). Unit does not run at idle speed  
when operated in MIG (CV) mode.  
Engine slowly stopped and cannot be  
restarted.  
Check fuel level. Open fuel shutoff valve (see Section 4-4).  
Check oil and water levels. Automatic shutdown system stops engine if oil pressure gets too low or  
coolant temperature gets too high (see Section 4-4).  
See engine manual.  
OM-477 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-477 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 8 ELECTRICAL DIAGRAMS  
193 965-A  
Figure 8-1. Circuit Diagram For Welding Generator For Standard Models  
OM-477 Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 8-2. Circuit Diagram For Welding Generator With Welders And Deluxe Package Options  
OM-477 Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
193 967-A  
OM-477 Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 9 AUXILIARY POWER GUIDELINES  
9-1. Selecting Equipment  
1
2
3
Auxiliary Power Receptacles  
Neutral Bonded To Frame  
3-Prong Plug From Case  
Grounded Equipment  
2-Prong Plug From Double  
Insulated Equipment  
1
2
3
Be sure equipment  
has this symbol  
and/or wording.  
OR  
aux_pwr 2/99 Ref. ST-159 730 / ST-800 577  
9-2. Grounding Generator To Truck Or Trailer Frame  
1
2
3
Generator Base  
Metal Vehicle Frame  
Equipment Grounding  
Terminal  
4
Grounding Cable  
Use #10 AWG or larger insulated  
copper wire.  
Y
If unit does not have GFCI re-  
ceptacles, use GFCI-pro-  
tected extension cord.  
3
4
1
GND/PE  
2
OR  
Electrically bond generator  
frame to vehicle frame by  
metal-to-metalcontact.  
2
S-0854  
OM-477 Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-3. Grounding When Supplying Building Systems  
1
2
EquipmentGrounding  
Terminal  
1
2
Grounding Cable  
GND/PE  
Use #10 AWG or larger insulated  
copper wire.  
3
Ground Device  
Y
Ground generator to system  
earth ground if supplying  
power to a premises (home,  
shop, farm) wiring system.  
Use ground device as stated  
in electrical codes.  
2
3
ST-800 576-B  
9-4. How Much Power Does Equipment Require?  
1
Resistive Load  
3
A light bulb is a resistive load and  
requires a constant amount of pow-  
er.  
VOLTS 115  
AMPS 4.5  
Hz 60  
2
1
2
Non-Resistive Load  
Equipmentwith a motor is a non-re-  
sistive load and requires approxi-  
mately six times more power while  
starting the motor than when run-  
ning (see Section 9-8).  
3
3
Rating Data  
Rating shows volts and amperes,  
or watts required to run equipment.  
AMPERES x VOLTS = WATTS  
EXAMPLE 1: If a drill uses 4.5 amperes at 115 volts, calculate its running power  
requirementin watts.  
4.5 A x 115 V = 520 W  
The load applied by the drill is 520 watts.  
EXAMPLE 2: If three 200 watt flood lamps are used with the drill from Example 1,  
add the individual loads to calculate total load.  
(200 W + 200 W + 200 W) + 520 W = 1120 W  
The total load applied by the three flood lamps and drill is 1120 watts.  
S-0623  
OM-477 Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-5. Approximate Power Requirements For Industrial Motors  
Industrial Motors  
Rating  
Starting Watts  
Running Watts  
Split Phase  
1/8 HP  
1/6 HP  
1/4 HP  
1/3 HP  
1/2 HP  
1/3 HP  
1/2 HP  
3/4 HP  
1 HP  
800  
1225  
1600  
2100  
3175  
2020  
3075  
4500  
6100  
8200  
10550  
15900  
23300  
8100  
23300  
35000  
46700  
1000  
1400  
1850  
2400  
3500  
300  
500  
600  
700  
875  
Capacitor Start-Induction Run  
720  
975  
1400  
1600  
2200  
2850  
3900  
6800  
2000  
6000  
8000  
10700  
400  
1-1/2 HP  
2 HP  
3 HP  
5 HP  
Capacitor Start-Capacitor Run  
1-1/2 HP  
5 HP  
7-1/2 HP  
10 HP  
1/8 HP  
1/6 HP  
1/4 HP  
1/3 HP  
1/2 HP  
Fan Duty  
550  
650  
800  
1100  
9-6. Approximate Power Requirements For Farm/Home Equipment  
Farm/HomeEquipment  
Rating  
Starting Watts  
Running Watts  
Stock Tank De-Icer  
1000  
1650  
3400  
4400  
2900  
10500  
1720  
2575  
4500  
6100  
8200  
10550  
15900  
23300  
8100  
23300  
35000  
46700  
3300  
3150  
4500  
6100  
3100  
2150  
3100  
2100  
3200  
1000  
650  
Grain Cleaner  
1/4 HP  
1/2 HP  
3/4 HP  
Portable Conveyor  
Grain Elevator  
1000  
1400  
1100  
2800  
720  
Milk Cooler  
Milker (Vacuum Pump)  
FARM DUTY MOTORS  
Std. (e.g. Conveyors,  
Feed Augers, Air  
Compressors)  
2 HP  
1/3 HP  
1/2 HP  
3/4 HP  
1 HP  
975  
1400  
1600  
2200  
2850  
3900  
6800  
2000  
6000  
8000  
10700  
1000  
950  
1-1/2 HP  
2 HP  
3 HP  
5 HP  
High Torque (e.g. Barn  
1-1/2 HP  
5 HP  
Cleaners, Silo Unloaders,  
Silo Hoists, Bunk Feeders)  
7-1/2 HP  
10 HP  
1/2 HP  
500 PSI  
550 PSI  
700 PSI  
3-1/2 cu. ft. Mixer  
High Pressure 1.8 Gal/Min  
Washer 2 gal/min  
2 gal/min  
1400  
1600  
800  
Refrigerator or Freezer  
Shallow Well Pump  
1/3 HP  
1/2 HP  
1/3 HP  
1/2 HP  
750  
1000  
800  
Sump Pump  
1050  
OM-477 Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-7. Approximate Power Requirements For Contractor Equipment  
Contractor  
Rating  
Starting Watts  
Running Watts  
Hand Drill  
1/4 in  
3/8 in  
350  
400  
350  
400  
1/2 in  
600  
600  
Circular Saw  
Table Saw  
6-1/2 in  
7-1/4 in  
8-1/4 in  
9 in  
500  
500  
900  
900  
1400  
4500  
6300  
2500  
1720  
3900  
5200  
3000  
6000  
8200  
10500  
1100  
1100  
350  
1400  
1500  
1800  
1100  
720  
10 in  
Band Saw  
14 in  
Bench Grinder  
6 in  
8 in  
1400  
1600  
1000  
1500  
2200  
2800  
1100  
1100  
350  
10 in  
Air Compressor  
1/2 HP  
1 HP  
1-1/2 HP  
2 HP  
Electric Chain Saw  
Electric Trimmer  
Electric Cultivator  
1-1/2 HP, 12 in  
2 HP, 14 in  
Standard 9 in  
Heavy Duty 12 in  
1/3 HP  
500  
500  
2100  
400  
700  
Elec. Hedge Trimmer  
Flood Lights  
18 in  
400  
HID  
125  
100  
Metal Halide  
Mercury  
Sodium  
Vapor  
313  
250  
1000  
1400  
1250  
600  
1000  
200  
Submersible Pump  
Centrifugal Pump  
Floor Polisher  
400 gph  
900 gph  
3/4 HP, 16 in  
1 HP, 20 in  
1/2 HP  
900  
500  
4500  
6100  
3150  
4500  
6100  
1900  
900  
1400  
1600  
950  
High Pressure Washer  
3/4 HP  
1400  
1600  
700  
1 HP  
55 gal Drum Mixer  
Wet & Dry Vac  
1/4 HP  
1.7 HP  
900  
2-1/2 HP  
1300  
1300  
OM-477 Page 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-8. Power Required To Start Motor  
1
2
3
4
Motor Start Code  
Running Amperage  
Motor HP  
4
AC MOTOR  
VOLTS 230 AMPS 2.5  
Hz 60  
PHASE 1  
2
1
3
CODE  
HP  
M
Motor Voltage  
1/4  
To find starting amperage:  
Step 1: Find code and use table to  
find kVA/HP. If code is not listed,  
multiplyrunning amperage by six to  
find starting amperage.  
Step 2: Find Motor HP and Volts.  
Step 3: Determine starting amper-  
age (see example).  
Welding generator amperage out-  
put must be at least twice the  
motors running amperage.  
Single-Phase Induction Motor Starting Requirements  
Motor Start  
Code  
G
H
J
K
L
M
N
P
KVA/HP  
6.3  
7.1  
8.0  
9.0  
10.0  
11.2  
12.5  
14.0  
kVA/HP x HP x 1000  
VOLTS  
= STARTING AMPERAGE  
EXAMPLE: Calculate the starting amperage required for a 230 V, 1/4  
HP motor with a motor start code of M.  
Volts = 230 HP = 1/4 Using Table, Code M results in kVA/HP = 11.2  
11.2 x 1/4 x 1000  
= 12.2 A  
Starting the motor requires 12.2 amperes.  
230  
S-0624  
9-9. How Much Power Can Generator Supply?  
1
Limit Load To 90% Of  
Generator Output  
Always start non-resistive (motor)  
loads in order from largest to small-  
est, and add resistive loads last.  
2
5 Second Rule  
1
If motor does not start within 5  
seconds, turn off power to prevent  
motor damage. Motor requires  
more power than generator can  
supply.  
2
Ref. ST-800 396-A / S-0625  
OM-477 Page 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-10. Typical Connections To Supply Standby Power  
1
2
3
Power Company Service  
Meter  
Main and Branch Overcurrent  
Protection  
Double-Pole, Double-Throw  
Transfer Switch  
Obtain and install correct switch.  
Switch rating must be same as or  
greater than the branch overcurrent  
protection.  
. Customer-supplied equipment is required if  
generator is to supply standby power during  
emergenciesor power outages.  
4
Circuit Breakers or Fused  
Disconnect Switch  
1
240 V  
Obtain and install correct circuit  
breakers or switch.  
120/240 Volt  
5
Extension Cord  
Select as shown in Section 9-11.  
Generator Connections  
120 V  
60 Hz  
Three-Wire  
Service  
120 V  
6
Connect terminals or plug of ade-  
quate amperage capacity to cord.  
Follow all applicable codes and  
safety practices.  
2
3
Turn off or unplug all equipment  
connected to generator before  
starting or stopping engine. When  
starting or stopping, the engine has  
low speed which causes low volt-  
age and frequency.  
240 V  
120 V  
Load  
120 V  
7
Load Connections  
4
7
CB  
or  
Item 4 is not necessary if circuit  
protection is already present in  
welding generator auxiliary  
power output circuit.  
F1  
5
6
240 V  
120/240 Volt  
Single-Phase  
Three-Wire  
120 V  
120 V  
Generator Output  
Connection  
Ground  
S-0405-A  
OM-477 Page 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-11. Selecting Extension Cord (Use Shortest Cord Possible)  
Cord Lengths for 120 Volt Loads  
Y
If unit does not have GFCI receptacles, use GFCI-protected extension cord.  
Maximum Allowable Cord Length in ft (m) for Conductor Size (AWG)*  
Current  
(Amperes)  
Load (Watts)  
4
6
8
10  
12  
14  
5
600  
350 (106)  
250 (76)  
175 (53)  
112 (34)  
87 (26)  
62 (19)  
50 (15)  
50 (15)  
37 (11)  
225 (68)  
150 (46)  
112 (34)  
75 (23)  
50 (15)  
37 (11)  
37 (11)  
137 (42)  
100 (30)  
62 (19)  
37 (11)  
30 (9)  
100 (30)  
62 (19)  
50 (15)  
30 (9)  
7
840  
400 (122)  
275 (84)  
175 (53)  
137 (42)  
112 (34)  
87 (26)  
10  
15  
20  
25  
30  
35  
40  
45  
50  
1200  
1800  
2400  
3000  
3600  
4200  
4800  
5400  
6000  
400 (122)  
300 (91)  
225 (68)  
175 (53)  
150 (46)  
125 (38)  
112 (34)  
100 (30)  
87 (26)  
75 (23)  
62 (19)  
62 (19)  
50 (15)  
*Conductor size is based on maximum 2% voltage drop  
Cord Lengths for 240 Volt Loads  
Y
If unit does not have GFCI receptacles, use GFCI-protected extension cord.  
Maximum Allowable Cord Length in ft (m) for Conductor Size (AWG)*  
Current  
(Amperes)  
Load (Watts)  
4
6
8
10  
12  
14  
5
1200  
1680  
2400  
3600  
4800  
6000  
7000  
8400  
9600  
10,800  
12,000  
700 (213)  
500 (152)  
350 (107)  
225 (69)  
175 (53)  
125 (38)  
100 (31)  
100 (31)  
75 (23)  
450 (137)  
300 (91)  
225 (69)  
150 (46)  
100 (31)  
75 (23)  
225 (84)  
200 (61)  
125 (38)  
75 (23)  
200 (61)  
125 (38)  
100 (31)  
60 (18)  
7
800 (244)  
550 (168)  
350 (107)  
275 (84)  
225 (69)  
175 (53)  
150 (46)  
125 (38)  
125 (38)  
100 (31)  
10  
15  
20  
25  
30  
35  
40  
45  
50  
800 (244)  
600 (183)  
450 (137)  
350 (107)  
300 (91)  
250 (76)  
225 (69)  
200 (61)  
175 (53)  
60 (18)  
75 (23)  
*Conductor size is based on maximum 2% voltage drop  
OM-477 Page 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-477 Page 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 10 PARTS LIST  
.
H
a
r
d
w
a
r
e
i
s
c
o
m
m
o
n
a
n
d
not available unless listed.  
4
3
5
2
1
18  
6
17  
116  
115  
114  
113  
112  
111  
49  
65  
16  
11  
66  
110  
15  
10  
12  
9
109  
67  
68  
7
8
14  
13  
69  
108  
107  
106  
105  
70  
104  
103  
Fig 10-3  
102  
101  
71  
100  
72  
99  
98  
97  
80  
81  
73  
74  
90  
89  
75  
88  
91  
92  
87  
82  
83  
86  
85 84  
76  
93  
79  
78  
94  
77  
96  
95  
Figure 10-1. Main Assembly  
OM-477 Page 46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
19  
21  
22  
30  
31  
23  
25  
24  
29  
28  
27  
26  
25  
32  
33  
62  
63  
64  
61  
34  
35  
36  
37  
38  
40  
60  
47  
Includes  
Item 49  
46  
45  
50  
51  
52  
53  
41  
54  
55  
48  
59  
Fig 10-2  
56  
44  
57  
58  
39  
43  
42  
ST-115 004-P  
OM-477 Page 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Figure 10-1. Main Assembly  
Quantity  
. . . 1 . . . . . . . . . . . . . . . . . . 134 771 . . . PLUG, protective .640sq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 2 . . . . . . . . . . . . . . . . . . 184 677 . . . TANK, fuel (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . . . . . 182 022 . . . . CAP, fuel large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . . . . . . 146 357 . . . SENDER, fuel gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 020 108 . . . FLANGE, fuel gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . . . . . . 602 938 . . . FITTING, pipe galv plug sqhd .125NPT . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . . . . . . 097 507 . . . STRIP, rbr adh back .125 x 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 7 . . . . . . . . . . . . . . . . . . 010 314 . . . VALVE, shut-off fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . . . . . . 173 818 . . . FITTING, hose brs barbed elbow M 1/4tbg x 1/4NPT . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . . . . . . 084 173 . . . CLAMP, hose .460-.545 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 10 . . . . . . . . . . . . . . . . . . 107 816 . . . HOSE, SAE .250 ID x .500 OD (order by ft) . . . . . . . . . . . . . . . . . . . . 2ft  
. . . 11 . . . . . . . . . . . . . . . . . . 047 420 . . . FILTER, fuel in line .250 w/hose & clamps . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . . . . . . 017 479 . . . SEAL, weather lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . . . . . . . . . . . . . 188 235 . . . UPRIGHT, base center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . . . . . . . 072 848 . . . TUBING, nprn .875 OD x 2.500 OD x 2.000 . . . . . . . . . . . . . . . . . . . . 4  
. . . 15 . . . . . . . . . . . . . . . . . . 071 730 . . . TUBING, stl .875 OD x 12ga x 2.375 . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 16 . . . . . . . . . . . . . . . . . . 071 890 . . . RETAINER, mount eng/gen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 17 . . . . . . . . . . . . . . . . . . 071 731 . . . WASHER, flat stl .656 ID x 2.250 OD . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 18 . . . . . . . . . . . . . . . . . . 601 945 . . . SCREW, .625-18 x 4.000 hexhd stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 19 . . . . . . . . . . . . . . . . . . 018 765 . . . AIR CLEANER, intake carb (consisting of) . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . . . . . . . . . . . . . . 018 859 . . . . CAP, air cleaner intake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . . . . . 008 698 . . . . BAFFLE, dust cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . . . . 021 117 . . . . NUT, stl wing .437-20 w/washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . . . . *017 309 . . . . ELEMENT, air cleaner carb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . . . . . . 000 272 . . . . CLAMP, air cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . . . . . . . . 031 868 . . . BRACKET, mtg air cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 26 . . . . . . . . . . . . . . . . . . 010 875 . . . CLAMP, muffler 2.000dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 27 . . . . . . . . . . . . . . . . . . 105 740 . . . MUFFLER, exhaust engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . . . . . . . . . . . . . . . 035 968 . . . WASHER, flat rbr 3.625 ID x 5.875 OD . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 195 869 . . . CABLE TIE, 0-17.500 weather resistant . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 29 . . . . . . . . . . . . . . . . . . 108 487 . . . LABEL, warning falling equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 30 . . . . . . . . . . . . . . . . . +105 631 . . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 057 359 . . . BLANK, snap-in nyl .375mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 31 . . . . . . . . . . . . . . . . . . 028 089 . . . DOOR, access radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 191 865 . . . BUMPER, door access radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 32 . . . . . . . . . . . . . . . . . . 089 343 . . . RIVET, nyl .250dia x 1.000 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . 33 . . . . . . . . . . . . . . . . . . 004 130 . . . BRACKET, support door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 34 . . . . . . . . . . . . . . . . . +089 510 . . . DOOR, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 114 793 . . . LABEL, engine maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 35 . . . . . . . . . . . . . . . . . . 158 610 . . . LABEL, electric shock and moving parts . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 36 . . . . . . . . . . . . . . . . . . 087 336 . . . LATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 087 341 . . . BUMPER, door 1.000 OD x .750 high . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 37 . . . . . . . . . . . . . . . . . . 197 464 . . . RADIATOR, w/shroud (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 38 . . . . . . . . . . . . . . . . . . 605 982 . . . . CAP, radiator pressure 7 lb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 39 . . . . . . . . . . . . . . . . . . 006 015 . . . . FITTING, pipe brs drain cock 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 40 . . . . . . . . . . . . . . . . . . 197 826 . . . GUARD, fan upper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 41 . . . . . . . . . . . . . . . . . . 109 792 . . . ENCLOSURE, radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 42 . . . . . . . . . . . . . . . . . . 147 923 . . . LABEL, warning fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 43 . . . . . . . . . . . . . . . . . +197 908 . . . GUARD, fan RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 44 . . . . . . . . . . . . . . . . . . 010 862 . . . CLAMP, hose 1.312 2.250clp dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . 45 . . . . . . . . . . . . . . . . . . 113 676 . . . HOSE, radiator lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 46 . . . . . . . . . . . . . . . . . . 084 979 . . . HOSE, radiator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 47 . . . . . . . . . . . . . . . . . +197 825 . . . GUARD, fan LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 48 . . . . . . . . . . . . . . . . . . 176 364 . . . ENGINE, gas elec start (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 49 . . . . . . . . . . . . . . . . . . 089 515 . . . . ANGLE, mtg engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 50 . . . . . . . . . . . . . . . . . . 115 857 . . . . BRACKET, mtg solenoid idle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 51 . . . . . TS1 . . . . . . . . 005 373 . . . . SOLENOID, 14VDC .84A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 52 . . . . . . . . . . . . . . . . . . 010 837 . . . . PIN, spring CS .093 x .625 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-477 Page 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-1. Main Assembly (Continued)  
. . . 53 . . . . . . . . . . . . . . . . . . 113 658 . . . . LINKAGE, throttle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 54 . . . . . FS1 . . . . . . . . . . . . . . . . . . . . CARBURETOR, (see engine parts list) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 55 . . . . . . . . . . . . . . . . . . 602 887 . . . . FITTING, pipe brs plug hexhd 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 56 . . . . . . S7 . . . . . . . . 025 473 . . . . SWITCH, pressure oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 57 . . . . . . . . . . . . . . . . . . 010 289 . . . . FITTING, brs flrd invt conn M 1/4tbg x 1/8NPT . . . . . . . . . . . . . . . . 1  
. . . 58 . . . . . . . . . . . . . . . . . . 111 851 . . . . LINE, fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 087 318 . . . . CLAMP, stl cush 1.000dia x .203mtg hole . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 172 725 . . . . BOOT, starter eyelet terminal red . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 59 . . . . . . . . . . . . . . . . . . Fig 10-2 . . . GENERATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 60 . . . . Shunt . . . . . 030 084 . . . SHUNT, meter 50MV 600A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 61 . . . . . . . . . . . . . . . . . . 188 629 . . . HOSE, elbow air cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 62 . . . . . . . . . . . . . . . . . . 173 034 . . . TUBING, heat stove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 63 . . . . . . . . . . . . . . . . . . 010 863 . . . CLAMP, hose 1.125-3.000clp dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 64 . . . . . . . . . . . . . . . . . . 173 036 . . . HOSE, elb air cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 65 . . . . . . . . . . . . . . . . . . 134 779 . . . HOLD DOWN, bat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 66 . . . . . . . . . . . . . . . . . . 182 276 . . . CABLE, battery pos w/clamp (included w/engine) . . . . . . . . . . . . . . . . 1  
. . . 67 . . . . . . . . . . . . . . . . . . 047 812 . . . CABLE, battery neg (included w/engine) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 68 . . . . . . . . . . . . . . . . . . 108 081 . . . TERMINAL PROTECTOR, bat post . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 69 . . . . . BAT . . . . . . . . 071 678 . . . BATTERY, stor 12V 415crk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 70 . . . . . . . . . . . . . . . . . . 134 782 . . . BATTERY BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 71 . . . . . . . . . . . . . . . . . . 082 672 . . . BOLT, L stl .312-18 x 6.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 604 433 . . . NUT, stl slflkg hex hvy .312-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 72 . . . . . . . . . . . . . . . . . . 163 666 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 73 . . . . . . . . . . . . . . . . 186 008 . . . INSULATION, terminal strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 74 . . . . . . 3T . . . . . . 038 601 . . . BLOCK, term 30A 9P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 75 . . . . . . . . . . . . . . . . 155 731 . . . BRACKET, mtg terminal strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 76 . . . . . . . . . . . . . . . +134 902 . . . COVER, fuse box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 77 . . . . . . . . . . . . . . . . 185 000 . . . LABEL, warning auxiliary power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 78 . . . . . . . . . . . . . . . . 026 947 . . . STAND-OFF, insulated 2.50-20 x 1.000 lg . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 79 . . . . . . . . . . . . . . . +134 903 . . . FUSE, box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 80 . . . . . . . . . . . . . . . . 149 541 . . . HOLDER, fuse crtg 60A 250V 3 fuses . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 81 . . . . . F1-3 . . . . *012 625 . . . FUSE, crtg 45A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 82 . . . . . . . . . . . . . . . . . . 113 932 . . . GUARD, panel rcpt (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 83 . . . . . . . . . . . . . . . . . . 113 730 . . . . LABEL, warning stop engine before etc . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 84 . . . . . SR4 . . . . . . . 035 704 . . . RECTIFIER, integ 40A 800 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 85 . . . . . . . . . . . . . . . . . . 173 982 . . . PANEL, mtg components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 86 . . PLG9,RC9 . . . . . 168 071 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 87 . . . . . . D9 . . . . . . . . 192 307 . . . KIT, diode w/washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 88 . . . . . . C8 . . . . . . . . 170 674 . . . CAPACITOR BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 89 . . . . . . R6 . . . . . . . . 030 844 . . . RESISTOR, WW fxd 25W 25 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 605 741 . . . CLIP, mtg resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 90 . . . . . CR3 . . . . . . . 044 588 . . . RELAY, encl 12VDC 3PDT 10A/120VAC . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 91 . . . . . PC5 . . . . . 150 415 . . . CIRCUIT CARD, connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . PLG6-8 . . . . 141 450 . . . CONNECTOR, rect 10skt plug Amp 207396-1 . . . . . . . . . . . . . . . . . . 3  
. . . 92 . . . . . . . . . . . . . . . . 097 132 . . . STAND-OFF, No. 6-32 x .375 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
. . . 93 . . . . . PC6 . . . . . 152 966 . . . CIRCUIT CARD, filter HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 94 . . . . . . . . . . . . . . . . . +181 841 . . . PANEL, front lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 95 . . . . . . . . . . . . . . . . 134 792 . . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 96 . . . . . . . . . . . . . . . . 111 785 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 97 . . . . . . . . . . . . . . . . 112 003 . . . SWITCH, plrt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . 133 725 . . . LABEL, AC/DC polarity switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 98 . . . . . CT1 . . . . . . . . 105 370 . . . TRANSFORMER, current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 99 . . . . . . Z1 . . . . . . . . 084 814 . . . REACTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 100 . . . . Neg . . . . . . . . 039 046 . . . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 101 . . . . Pos . . . . . . . 039 047 . . . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 102 . . . . . . . . . . . . . . . . . Fig 10-3 . . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 103 . . . . . . . . . . . . . . . . . 108 127 . . . BRACKET, mtg term pwr output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 104 . . . . PC4 . . . . . . . 148 608 . . . CIRCUIT CARD, filter HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 097 132 . . . STAND-OFF, No. 6-32 x .375 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 105 . . . . . . . . . . . . . . . . . 188 237 . . . UPRIGHT, base front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-477 Page 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-1. Main Assembly (Continued)  
. . 106 . . . . . . . . . . . . . . . . . 085 551 . . . FRAME, mtg reactor/fuel tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 107 . . . . . R3 . . . . . . . . 128 862 . . . RESISTOR, WW adj 375W 50 ohm w/mtg bkt . . . . . . . . . . . . . . . . . . 1  
. . 108 . . . . . . . . . . . . . . . . . 085 656 . . . STRIP, mtg resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 109 . . . . . . . . . . . . . . . . . 605 288 . . . FITTING, pipe galv plug sqhd .250NPT . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 110 . . . . . . . . . . . . . . . . . 070 010 . . . BOLT, J stl .250-20 x 2.312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 111 . . . . . . . . . . . . . . . . . 010 143 . . . CLAMP, nyl .375 clamp dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 112 . . . . . . . . . . . . . . . . . 138 027 . . . EDGE TRIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 113 . . . . . . . . . . . . . . . . . 081 499 . . . BRACKET, mtg strip terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 114 . . . . TE4 . . . . . . . . 038 621 . . . BLOCK, term 30A 4P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 038 620 . . . LINK, jumper term blk 30A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 115 . . . . . . . . . . . . . . . . . 053 967 . . . INSULATION, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 116 . . . . . . . . . . . . . . . . . 089 517 . . . STRAP, fuel tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 010 021 . . . CLAMP, stl cush .562dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 136 310 . . . KIT, label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
*Recommended Spare Parts.  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
OPTIONAL  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
.
H
a
r
d
w
a
r
e
i
s
c
o
m
m
o
n
a
n
d
19  
not available unless listed.  
16  
18  
17  
14  
15  
13  
12  
7
9
10  
11  
8
3
12  
4
6
5
4
20  
2
1
22  
21  
23  
25  
26  
27  
28  
24  
Figure 10-2. Generator  
OM-477 Page 50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-2. Generator (Fig 10-1 Item 59)  
. . . 1 . . . . . . . . . . . . 106 426 . . INSULATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 2 . . . . . . . . . . . . 106 440 . . BUS BAR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 3 . . . SR3 . . . . 106 427 . . DIODE ASSEMBLY, reverse polarity (consisting of) . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . 048 420 . . . . CAPACITOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 106 641 . . . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . 037 957 . . . . DIODE, rect 275A 300V RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 6 . . . . . . . . . . . . 106 425 . . . . INSULATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 7 . . . . . . . . . . . . 173 066 . . BRACKET, mtg brushholder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . 018 614 . . BRUSH SET, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 9 . . . . . . . . . . . . *151 299 . . . . BRUSH, contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 10 . . . . . . . . . . . . 600 270 . . . . HOLDER, brush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 11 . . . . . . . . . . . . 152 044 . . . . CAP, brushholder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 12 . . . . . . . . . . . . 013 367 . . LABEL, warning moving parts can cause serious injury . . . . . . . . . . . . . . . . 2  
. . 13 . . . . . . . . . . . . . 110 371 . . GUARD, starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 14 . . . . . . . . . . . +128 730 . . STATOR, gen (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 14 . . . . . . . . . . +132 222 . . STATOR, gen (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 15 . . . . . . . . . . . . 039 207 . . . . BAFFLE, air gen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 16 . . . . . . . . . . . . 201 198 . . ROTOR, gen (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 17 . . . . . . . . . . . . 024 617 . . . . RING, retaining external . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 18 . . . . . . . . . . . . 053 390 . . . . BEARING, ball . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 19 . . . . . . . . . . . . 089 737 . . . . FAN, rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 035 776 . . . . KEY, .375 x .375 x 2.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 20 . . . . . . . . . . . . 044 374 . . STATOR, excitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 21 . . . . . . . . . . . . 173 068 . . ENDBELL, gen (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 22 . . . . . . . . . . . . 143 220 . . . . O-RING, 2.859 ID x .139CS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 23 . . . . . . . . . . . . 106 424 . . BARREL, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 163 271 . . EDGE TRIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 24 . . . SR3 . . . . 106 430 . . DIODE ASSEMBLY, straight polarity (consisting of) . . . . . . . . . . . . . . . . . . . 1  
. . 25 . . . . . . . . . . . . 048 420 . . . . CAPACITOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . 106 641 . . . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 26 . . . . . . . . . . . . 106 425 . . . . INSULATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . 27 . . . . . . . . . . . . 037 956 . . . . DIODE, rect 275A 300V SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . 28 . VR1,R4 . . 046 819 . . . . SUPPRESSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OPTIONAL  
*Recommended Spare Parts.  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-477 Page 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-3. Panel, Front w/Components (Fig 10-1 Item 102)  
. . . 1 . . . . . . . . . . . . . . . . . . 010 647 . . . PIN, spring CS .156 x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . . . . . . 044 328 . . . HANDLE, switch range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLATE, ident control rating (order by model and serial number) . . . 1  
. . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . S1 . . . . . . . . 172 070 . . . SWITCH, ign 5posn w/out handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LO OIL & HI TEMP SHUTDOWN, (consisting of) . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 110 958 . . . . SWITCH, automatic shutdown (consisting of) . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . MS1 . . . . . . . 011 072 . . . . . . SWITCH, magnetic (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . F . . . . . . . . *048 317 . . . . . . . . FUSE, mintr gl 14A 32V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . D8 . . . . . . . . 087 970 . . . . . . DIODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . . . . . . 131 999 . . . PANEL, front upper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . . . . . . 086 706 . . . SPACER, range switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . S3 . . . . . . . . 119 850 . . . SWITCH, range/changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . . . . . . 086 991 . . . BRACKET, support switch range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Fig 10-4  
.
H
a
r
d
w
a
r
e
i
s
c
o
m
m
o
n
a
n
d
11  
12  
not available unless listed.  
6
8
9
10  
7
5
4
3
2
13  
1
14  
13  
15  
16  
38  
37  
17  
18  
39  
25  
36  
26  
35  
34  
33  
24  
19  
Includes  
Item 20  
32  
31  
30  
29  
23  
22  
28  
8
27  
3
20  
21  
ST-115 005-C  
Figure 10-3. Panel, Front w/Components  
OM-477 Page 52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-3. Panel, Front w/Components (Fig 10-1 Item 102)  
(Continued)  
. . . 12 . . . . . . . . . . . . . . . . . . Fig 10-4 . . . CONTROL BOX w/COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . CB1,2 . . . . . . . 139 266 . . . CIRCUIT BREAKER, man reset 1P 15A 250VAC . . . . . . . . . . . . . . . . 2  
. . . 14 . . . . RC1,2 . . . . . . . 170 901 . . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . . . . . . 2  
. . . 14 . . . GFCI1,2 . . . . 168 068 . . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 073 690 . . . PLUG, str grd armd 2P3W 15A 125V P & S 5266DF  
. . . . . . . . . . . . . . . . . . . . . . 042 655 . . . RECEPTACLE KIT, 240V (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . CB1,2 . . . . . . . 139 266 . . . . CIRCUIT BREAKER, man reset 1P 15A 250VAC . . . . . . . . . . . . . . 2  
. . . 14 . . . . . RC1 . . . . . . . 604 103 . . . . RECEPTACLE, str dx grd 2P3W 15A 250V . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . RC2 . . . . . . . 039 864 . . . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . RC3 . . . . . 143 976 . . . CONNECTOR w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 134 734 . . . CONNECTOR, circ 14 pin plug Amp 213571-2  
. . . . . . . . . . . . . . . . . . . . . . . . 134 731 . . . CONNECTOR, circ pin push-in 14-18ga Amp 213603-1  
. . . . . . . . . . . . . . . . . . . . . . . . 079 739 . . . CONNECTOR, circ clamp str rlf .703 max cable OD  
Amp 206322-2 (or)  
. . . . . . . . . . . . . . . . . . . . . . . . 143 922 . . . CONNECTOR, circ clamp str rlf .453 max cable OD  
Amp 206070-3  
. . . 16 . . . . CB3,4 . . . . . 083 432 . . . CIRCUIT BREAKER, man reset 1P 10A 250V . . . . . . . . . . . . . . . . . . 2  
. . . 17 . . . . . S4,5 . . . . . 011 609 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 18 . . . . . . . . . . . . . . . . . . 011 611 . . . SWITCH, tgl DPDT 15A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . R1 . . . . . . . . 072 462 . . . POTENTIOMETER, w/shaft lock (consisting of) . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . . . . . . . . . . . . . . 072 590 . . . . LOCK, shaft pot .375-32 x .250dia shaft . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . . . . . 022 289 . . . TUBING, stl .312 OD x .187 ID x .437 . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 22 . . . . . . . . . . . . . . . . . . 097 926 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . . . 021 385 . . . BOOT, tgl switch lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 24 . . . . . . . . . . . . . . . . . . 170 663 . . . HINGE, panel front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . . . . . . . . 083 030 . . . STUD, brs grd .250-20 x 1.750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 26 . . . . . . . . . . . . . . . . . . 601 836 . . . NUT, brs hex .250-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 27 . . . . . . A2 . . . . . . 046 652 . . . METER, amp dc 50MV 0-600 scale . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . . . V . . . . . . . 046 654 . . . METER, volt dc 0-100 scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 29 . . . . . . . . . . . . . . . . 170 391 . . . CONNECTOR, circ protective cap Amphenol 9760-20 . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ENGINE METER KIT, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 30 . . . . . . . . . . . . . . . . . . 047 842 . . . . GAUGE, pressure 5-100 lbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 31 . . . . . . . . . . . . . . . . . . 047 841 . . . . GAUGE, temperature mechanical 100/250deg . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 128 829 . . . . KIT, oil line 44.000 in 1/8NPT x 10mm . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 602 946 . . . . FITTING, pipe stl tee B 1/8NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 175 465 . . . . FITTING, pipe brs adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 162 380 . . . . FITTING, pipe stl adapter 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 32 . . . . . . . . . . . . . . . . . . 133 814 . . . CONTROL, push/pull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 33 . . . . . . . . . . . . . . . . . . 119 014 . . . LEVER, switch black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 34 . . . . . HM . . . . . . . . 145 247 . . . METER, hour 12-24VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . . 604 784 . . . SCREW, 6-32 x .500rdh-slot brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . . . . 601 829 . . . NUT, brs hex 6-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 35 . . . . . . . . . . . . . . . . . . 082 788 . . . HOLDER, light ind . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 36 . . . . . . . . . . . . . . . . . . 082 789 . . . LENS, light ind red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 37 . . . . PL1,2 . . . . . . *048 155 . . . BULB, incand flg base 12V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 38 . . . . . . FG . . . . . . . . 118 066 . . . GAUGE, fuel elec 12V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 39 . . . . . . . . . . . . . . . . . . 189 404 . . . SPACER, nylon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
OPTIONAL  
*Recommended Spare Parts.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-477 Page 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 10-4. Control Box w/Components (Fig 10-3 Item 12)  
. . . 1 . . . . . CR1 . . . . . . . 044 588 . . . RELAY, encl 12VDC 3PDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . R2 . . . . . . 130 515 . . . RESISTOR, board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . D1 . . . . . . . . 189 701 . . . DIODE/CAPACITOR BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . 2T . . . . . . . . 116 005 . . . BLOCK, term 10A 7P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . 1T . . . . . . . . 129 939 . . . BLOCK, term 10A 19P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . . . . . . 130 608 . . . MOUNTING BOX, components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . . . . . 603 107 . . . HOSE, nprn slit back .156 ID x .343 OD (order by ft) . . . . . . . . . . . . . 1ft  
. . . 8 . . . . . . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
. . . 9 . . . . . PC1 . . . . . 166 205 . . . CIRCUIT CARD, field current regulator . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . PLG1 . . . . . . . 135 275 . . . CONNECTOR PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . PC2 . . . . . . . 114 832 . . . CIRCUIT CARD, voltage regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . CR99 . . . . . . . 090 104 . . . RELAY, encl 12VDC SPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . SR2 . . . . . . . 097 353 . . . DIODE/SCR, bridge integ 2scr 3 diodes . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . SR1 . . . . . . . 035 704 . . . RECTIFIER, integ 40A 800V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . Idle Mod . . . . . . 189 742 . . . MODULE, pull to idle 5 pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
1
.
H
a
r
d
w
a
r
e
i
s
c
o
m
m
o
n
a
n
d
not available unless listed.  
2
3
4
5
14  
13  
12  
11  
PC2  
10  
PC1  
6
7
9
8
ST-109 773-C  
Figure 10-4. Control Box w/Components  
OPTIONAL  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-477 Page 54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 2000  
(Equipment with a serial number preface of LAor newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants  
to its original retail purchaser that new Miller equipment sold  
after the effective date of this limited warranty is free of defects  
in material and workmanship at the time it is shipped by Miller.  
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting  
Torches  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
Remote Controls  
Accessory Kits  
Replacement Parts (No labor)  
Spoolmate 185 & Spoolmate 250  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to  
such defects in material or workmanship. Miller must be  
notified in writing within thirty (30) days of such defect or  
failure, at which time Miller will provide instructions on the  
warranty claim procedures to be followed.  
Your distributor also gives  
you ...  
Millers True Blue Limited Warranty shall not apply to:  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings,  
relays or parts that fail due to normal wear.  
Service  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment  
listed below in the event of such a failure within the warranty  
time periods. All warranty time periods start on the date that  
the equipment was delivered to the original retail purchaser, or  
one year after the equipment is sent to a North American  
distributor or eighteen months after the equipment is sent to an  
International distributor.  
2. Items furnished by Miller, but manufactured by others,  
such as engines or trade accessories. These items are  
covered by the manufacturers warranty, if any.  
Support  
3. Equipment that has been modified by any party other  
than Miller, or equipment that has been improperly  
installed, improperly operated or misused based upon  
industry standards, or equipment which has not had  
reasonable and necessary maintenance, or equipment  
which has been used for operation outside of the  
specifications for the equipment.  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
1. 5 Years Parts 3 Years Labor  
*
*
Original main power rectifiers  
Inverters (input and output rectifiers only)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE  
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND  
PERSONS TRAINED AND EXPERIENCED IN THE USE  
AND MAINTENANCE OF WELDING EQUIPMENT.  
2. 3 Years Parts and Labor  
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Supplies  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Millers option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods  
at customers risk and expense. Millers option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by  
the engine manufacturer.)  
3. 1 Year Parts and Labor  
*
*
DS-2 Wire Feeder  
Motor Driven Guns (w/exception of Spoolmate  
185 & Spoolmate 250)  
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR  
ANY OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources  
Water Coolant Systems  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN  
AND ANY IMPLIED WARRANTY, GUARANTY OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
Grids  
Maxstar 140  
PROVISION,  
MIGHT  
ARISE  
BY  
IMPLICATION,  
Spot Welders  
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE  
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL  
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND  
DISCLAIMED BY MILLER.  
Load Banks  
Miller Cyclomatic Equipment  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Some states in the U.S.A. do not allow limitations of how long  
an implied warranty lasts, or the exclusion of incidental,  
indirect, special or consequential damages, so the above  
limitation or exclusion may not apply to you. This warranty  
provides specific legal rights, and other rights may be  
available, but may vary from state to state.  
*
Field Options  
(NOTE: Field options are covered under True  
Blue for the remaining warranty period of the  
product they are installed in, or for a minimum of  
one year whichever is greater.)  
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations  
and exclusions set out above may not apply. This Limited  
Warranty provides specific legal rights, and other rights may  
be available, but may vary from province to province.  
4. 6 Months Batteries  
5. 90 Days Parts  
*
*
MIG Guns/TIG Torches  
Induction Heating Coils and Blankets  
miller_warr 7/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owners Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
to locate a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters –  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
www.MillerWelds.com  
Contact the Delivering Carrier for:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims,  
contact your distributor and/or equipment  
manufacturers Transportation Department.  
PRINTED IN USA  
2000 Miller Electric Mfg. Co. 6/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Cooktop KM 443 User Manual
Milan Technology Switch MIL S341X User Manual
MTD Trimmer Y26SS User Manual
Neuton Lawn Mower EM 51 User Manual
New Holland Lawn Mower T9010 User Manual
Nikon Digital Camera 10mm f 28 AW Mirrorless User Manual
Nokia Cell Phone 311 User Manual
Onkyo Speaker System SKC 230C User Manual
Panasonic All in One Printer AGEP50 User Manual
Panasonic Camcorder AG HVX200AN User Manual