Miller Electric Welder 12VS User Manual

OM-1500-19  
219 185P  
200709  
Processes  
MIG (GMAW) Welding  
Flux Cored (FCAW) Welding  
Description  
Wire Feeder  
SuitCase  
X-TREME 12VS  
File: MIG (GMAW)  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
OPTIONS AND ACCESSORIES  
WARRANTY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Declaration of Conformity for  
European Community (CE) Products  
. This information is provided for units with CE certification (see rating label on unit).  
Manufacturer:  
European Contact:  
Miller Electric Mg. Co.  
1635 W. Spencer St.  
Appleton, WI 54914 USA  
Phone: (920) 734-9821  
Mr. Danilo Fedolfi,  
Managing Director  
ITW Welding Products Italy S.r.l.  
Via Privata Iseo 6/E  
20098 San Giuliano  
Milanese, Italy  
Phone: 39(02)98290-1  
Fax: 39(02)98290203  
European Contact Signature:  
Declares that this product:  
SuitCase X-TREME 12VS  
conforms to the following Directives and Standards:  
Directives  
Low Voltage Directive: 73/23/EEC, 2006/95/EC  
Electromagnetic Compatibility Directives: 89/336/EEC  
Machinery Directives: 98/37EEC, 91/368/EEC, 92/31/EEC, 133/04, 93/68/EEC  
Standards  
Arc Welding Equipment Part 5: Wire Feeders. IEC 60974-5 Ed. 1, 2002-02  
Arc Welding Equipment Part 10: Electromagnetic Compatibility (EMC) Requirements.  
IEC 60974-10 August 2002  
Arc Welding Equipment Part 1: Welding Power Sources. IEC 60974-1 Ed. 2.1  
Degrees Of Protection Provided By Enclosure (IP Code) IEC 60529 Ed. 2.1  
Insulation Coordination For Equipment Within Low-Voltage Systems −  
Part 1: Principles, Requirements and Tests: IEC 60664-1 Ed. 1.1  
The product technical file is maintained by the responsible Business Unit(s) located at the manufacturing facility.  
dec_stat_1/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _200704  
7
Protect yourself and others from injury — read and follow these precautions.  
1-1. Symbol Usage  
DANGER! Indicates a hazardous situation which, if  
not avoided, will result in death or serious injury. The  
possible hazards are shown in the adjoining symbols  
or explained in the text.  
. Indicates special instructions.  
Indicates a hazardous situation which, if not avoided,  
could result in death or serious injury. The possible  
hazards are shown in the adjoining symbols or ex-  
plained in the text.  
This group of symbols means Warning! Watch Out! ELECTRIC  
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-  
bols and related instructions below for necessary actions to avoid the  
hazards.  
NOTICE Indicates statements not related to personal injury.  
1-2. Arc Welding Hazards  
D
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
The symbols shown below are used throughout this manual  
to call attention to and identify possible hazards. When you  
see the symbol, watch out, and follow the related instructions  
to avoid the hazard. The safety information given below is  
only a summary of the more complete safety information  
follow all Safety Standards.  
D
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Keep cords dry, free of oil and grease, and protected from hot metal  
and sparks.  
Only qualified persons should install, operate, maintain, and  
repair this unit.  
Frequently inspect input power cord for damage or bare wiring −  
replace cord immediately if damaged bare wiring can kill.  
D
D
D
D
Turn off all equipment when not in use.  
During operation, keep everybody, especially children, away.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
If earth grounding of the workpiece is required, ground it directly  
with a separate cable.  
ELECTRIC SHOCK can kill.  
D
D
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
Do not touch electrode holders connected to two welding ma-  
chines at the same time since double open-circuit voltage will be  
present.  
power circuit and machine internal circuits are also  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
Use AC output ONLY if required for the welding process.  
If AC output is required, use remote output control if present on  
unit.  
Additionalsafety precautions are required when any of the follow-  
ing electrically hazardous conditions are present: in damp  
locations or while wearing wet clothing; on metal structures such  
as floors, gratings, or scaffolds; when in cramped positions such  
as sitting, kneeling, or lying; or when there is a high risk of unavoid-  
able or accidental contact with the workpiece or ground. For these  
conditions, use the following equipment in order presented: 1) a  
semiautomaticDC constant voltage (wire) welder, 2) a DC manual  
(stick) welder, or 3) an AC welder with reduced open-circuit volt-  
age. In most situations, use of a DC, constant voltage wire welder  
is recommended. And, do not work alone!  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
D
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
D
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
D
D
SIGNIFICANT DC VOLTAGE exists in inverter-type  
welding power sources after removal of input  
power.  
D
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
HOT PARTS can cause severe burns.  
D
D
Do not touch hot parts bare handed.  
Allow cooling period before working on gun or  
torch.  
D
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
D
To handle hot parts, use proper tools and/or  
wear heavy, insulated welding gloves and  
clothing to prevent burns.  
Properly install and ground this equipment according to its  
Owner’s Manual and national, state, and local codes.  
OM-1500-19 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
D
D
Do not use welder to thaw frozen pipes.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
After completion of work, inspect area to ensure it is free of sparks,  
glowing embers, and flames.  
Use only correct fuses or circuit breakers. Do not oversize or by-  
pass them.  
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B  
for hot work and have a fire watcher and extinguisher nearby.  
FUMES AND GASES can be hazardous.  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
D
D
D
D
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
If inside, ventilate the area and/or use local forced ventilation at the  
arc to remove welding fumes and gases.  
D
D
If ventilation is poor, wear an approved air-supplied respirator.  
Read and understand the Material Safety Data Sheets (MSDSs)  
and the manufacturer’s instructions for metals, consumables,  
coatings, cleaners, and degreasers.  
D
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
FLYING METAL or DIRT can injure eyes.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
D
Wear approved safety glasses with side  
shields even under your welding helmet.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and while wearing an air-supplied  
respirator. The coatings and any metals containing these elements  
can give off toxic fumes if welded.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
ARC RAYS can burn eyes and skin.  
MAGNETIC FIELDS can affect Implanted  
Medical Devices.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
D
Wearers of Pacemakers and other Implanted  
Medical Devices should keep away.  
D
Wear an approved welding helmet fitted with a proper shade of fil-  
ter lenses to protect your face and eyes when welding or watching  
(see ANSI Z49.1 and Z87.1 listed in Safety Standards).  
D
ImplantedMedical Device wearers should consult their doctor  
and the device manufacturer before going near arc welding, spot  
welding, gouging, plasma arc cutting, or induction heating  
operations.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
Use protective screens or barriers to protect others from flash,  
glare and sparks; warn others not to watch the arc.  
NOISE can damage hearing.  
Noise from some processes or equipment can  
damagehearing.  
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather, heavy cotton, or wool) and foot protection.  
D
Wear approved ear protection if noise level is  
high.  
WELDING can cause fire or explosion.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
CYLINDERS can explode if damaged.  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, physical damage, slag, open flames, sparks, and arcs.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
Turn face away from valve outlet when opening cylinder valve.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
D
D
D
Do not weld where flying sparks can strike flammable material.  
Protect yourself and others from flying sparks and hot metal.  
D
D
D
D
D
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
D
D
D
D
Do not weld where the atmosphere may contain flammable dust,  
gas, or liquid vapors (such as gasoline).  
D
D
Use the right equipment, correct procedures, and sufficient num-  
ber of persons to lift and move cylinders.  
Read and follow instructions on compressed gas cylinders,  
associated equipment, and Compressed Gas Association (CGA)  
publication P-1 listed in Safety Standards.  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock, sparks, and fire  
hazards.  
OM-1500-19 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
Do not install unit near flammables.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
D
D
Have only qualified persons remove doors, panels, covers, or  
guards for maintenance as necessary.  
Reinstall doors, panels, covers, or guards when maintenance is  
finished and before reconnecting input power.  
FALLING UNIT can cause injury.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
Use equipment of adequate capacity to lift and  
support unit.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
READ INSTRUCTIONS.  
D
Read Owner’s Manual before using or servic-  
ing unit.  
D
Use only genuine replacement parts from the  
manufacturer.  
OVERUSE can cause OVERHEATING  
H.F. RADIATION can cause interference.  
D
D
Allow cooling period; follow rated duty cycle.  
Reduce current or reduce duty cycle before  
starting to weld again.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
Have only qualified persons familiar with  
electronic equipment perform this installation.  
D
Do not block or filter airflow to unit.  
D
FLYING SPARKS can cause injury.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
D
D
Wear a face shield to protect eyes and face.  
Shape tungsten electrode only on grinder with  
proper guards in a safe location wearing proper  
face, hand, and body protection.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
D
D
Have the installation regularly checked and maintained.  
D
Sparks can cause fires — keep flammables away.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
STATIC (ESD) can damage PC boards.  
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
ARC WELDING can cause interference.  
D
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
MOVING PARTS can cause injury.  
D
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
Do not press gun trigger until instructed to do  
so.  
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
D
OM-1500-19 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-4. California Proposition 65 Warnings  
For Gasoline Engines:  
Welding or cutting equipment produces fumes or gases  
which contain chemicals known to the State of California to  
cause birth defects and, in some cases, cancer. (California  
Health & Safety Code Section 25249.5 et seq.)  
Engine exhaust contains chemicals known to the State of  
California to cause cancer, birth defects, or other reproduc-  
tive harm.  
For Diesel Engines:  
Battery posts, terminals and related accessories contain lead  
and lead compounds, chemicals known to the State of  
California to cause cancer and birth defects or other  
reproductiveharm. Wash hands after handling.  
Diesel engine exhaust and some of its constituents are  
known to the State of California to cause cancer, birth  
defects, and other reproductive harm.  
1-5. Principal Safety Standards  
Safety inWelding, Cutting, and Allied Processes, ANSI Standard Z49.1,  
from Global Engineering Documents (phone: 1-877-413-5184, website:  
www.global.ihs.com).  
Ontario, Canada L4W 5NS (phone: 800-463-6727 or in Toronto  
416-747-4044,website: www.csa-international.org).  
Safe Practice For Occupational And Educational Eye And Face Protec-  
tion, ANSI Standard Z87.1, from American National Standards Institute,  
25 West 43rd Street, New York, NY 10036–8002 (phone:  
212-642-4900,website: www.ansi.org).  
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, from National Fire Protection Association,  
P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, web-  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers and Piping, American Welding Society Standard  
AWS F4.1, from Global Engineering Documents (phone:  
1-877-413-5184,website: www.global.ihs.com).  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone:  
OSHA, Occupational Safety and Health Standards for General Indus-  
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,  
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-  
intendentof Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954  
(phone: 1-866-512-1800) (there are 10 Regional Offices—phone for  
Region 5, Chicago, is 312-353-2220, website: www.osha.gov).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 4221 Walney Road, 5th Floor,  
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
CanadianStandards Association, Standards Sales, 5060 Mississauga,  
1-6. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them, or using a  
cable cover.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: “The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Implanted Medical Devices:  
ImplantedMedical Device wearers should consult their doctor and the  
device manufacturer before performing or going near arc welding, spot  
welding, gouging, plasma arc cutting, or induction heating operations.  
If cleared by your doctor, then following the above procedures is recom-  
mended.  
To reduce magnetic fields in the workplace, use the following  
procedures:  
OM-1500-19 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION  
fre_som_200704  
7
Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.  
2-1. Symboles utilisés  
DANGER! Indique une situation dangereuse qui si on  
l’évite pas peut donner la mort ou des blessures graves.  
Les dangers possibles sont montrés par les symboles  
joints ou sont expliqués dans le texte.  
. Indique des instructions spécifiques.  
Indique une situation dangereuse qui si on l’évite pas  
peut donner la mort ou des blessures graves. Les dan-  
gers possibles sont montrés par les symboles joints ou  
sont expliqués dans le texte.  
Ce groupe de symboles veut dire Avertissement! Attention! DANGER  
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES  
CHAUDES. Consulter les symboles et les instructions ci-dessous y  
afférant pour les actions nécessaires afin d’éviter le danger.  
NOTE Indique des déclarations pas en relation avec des blessures  
personnelles.  
2-2. Dangers relatifs au soudage à l’arc  
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à  
souder AC à tension à vide réduite. Dans la plupart des situations,  
l’utilisation d’un poste à souder DC à fil à tension constante est re-  
commandée.En outre, ne pas travailler seul !  
Les symboles représentés ci-dessous sont utilisés dans ce ma-  
nuel pour attirer l’attention et identifier les dangers possibles. En  
présence de l’un de ces symboles, prendre garde et suivre les  
instructions afférentes pour éviter tout risque. Les instructions  
en matière de sécurité indiquées ci-dessous ne constituent  
qu’un sommaire des instructions de sécurité plus complètes  
fournies dans les normes de sécurité énumérées dans la Sec-  
tion 2-5. Lire et observer toutes les normes de sécurité.  
D
Couper l’alimentation ou arrêter le moteur avant de procéder à l’in-  
stallation, à la réparation ou à l’entretien de l’appareil. Déverrouiller  
l’alimentationselon la norme OSHA 29 CFR 1910.147 (voir nor-  
mes de sécurité).  
Installer le poste correctement et le mettre à la terre convenable-  
ment selon les consignes du manuel de l’opérateur et les normes  
nationales,provinciales et locales.  
Toujours vérifier la terre du cordon d’alimentation. Vérifier et  
s’assurer que le fil de terre du cordon d’alimentation est bien  
raccordé à la borne de terre du sectionneur ou que la fiche du  
cordon est raccordée à une prise correctement mise à la terre.  
D
D
Seul un personnel qualifié est autorisé à installer, faire fonc-  
tionner, entretenir et réparer cet appareil.  
Pendant le fonctionnement, maintenir à distance toutes les  
personnes,notamment les enfants de l’appareil.  
D
D
En effectuant les raccordements d’entrée, fixer d’abord le conduc-  
teur de mise à la terre approprié et contre-vérifier les connexions.  
UNE DÉCHARGE ÉLECTRIQUE peut  
entraîner la mort.  
Les câbles doivent être exempts d’humidité, d’huile et de graisse;  
protégezles contre les étincelles et les pièces métalliques  
chaudes.  
Le contact d’organes électriques sous tension peut  
provoquer des accidents mortels ou des brûlures  
graves. Le circuit de l’électrode et de la pièce est  
sous tension lorsque le courant est délivré à la  
D
Vérifier fréquemment le cordon d’alimentation afin de s’assurer  
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.  
Un fil à nu peut entraîner la mort.  
sortie. Le circuit d’alimentation et les circuits internes de la machine  
sont également sous tension lorsque l’alimentation est sur Marche.  
Dans le mode de soudage avec du fil, le fil, le dérouleur, le bloc de  
commande du rouleau et toutes les parties métalliques en contact  
avec le fil sont sous tension électrique. Un équipement installé ou mis  
à la terre de manière incorrecte ou impropre constitue un danger.  
D
D
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-  
sante ou mal épissés.  
D
D
Ne pas enrouler les câbles autour du corps.  
D
D
Ne pas toucher aux pièces électriques sous tension.  
Si la pièce soudée doit être mise à la terre, le faire directement  
avec un câble distinct.  
Porter des gants isolants et des vêtements de protection secs et  
sans trous.  
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce,  
la terre ou une électrode provenant d’une autre machine.  
D
D
S’isoler de la pièce à couper et du sol en utilisant des housses ou  
des tapis assez grands afin d’éviter tout contact physique avec la  
pièce à couper ou le sol.  
Ne pas toucher des porte électrodes connectés à deux machines  
en même temps à cause de la présence d’une tension à vide dou-  
blée.  
Ne pas se servir de source électrique à courant électrique dans les  
zones humides, dans les endroits confinés ou là où on risque de  
tomber.  
D
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir l’appareil  
conformémentà ce manuel.  
D
D
Se servir d’une source électrique à courant électrique UNIQUE-  
MENT si le procédé de soudage le demande.  
D
D
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.  
Si l’utilisation d’une source électrique à courant électrique s’avère  
nécessaire, se servir de la fonction de télécommande si l’appareil  
en est équipé.  
S’assurer que tous les panneaux et couvercles sont correctement  
en place.  
D
D’autres consignes de sécurité sont nécessaires dans les condi-  
tions suivantes : risques électriques dans un environnement  
humideou si l’on porte des vêtements mouillés ; sur des structures  
métalliquestelles que sols, grilles ou échafaudages ; en position  
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque  
élevé de contact inévitable ou accidentel avec la pièce à souder ou  
le sol. Dans ces conditions, utiliser les équipements suivants,  
dans l’ordre indiqué : 1) un poste à souder DC à tension constante  
D
Fixer le câble de retour de façon à obtenir un bon contact métal-  
métal avec la pièce à souder ou la table de travail, le plus près  
possible de la soudure.  
D
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le  
contact avec tout objet métallique.  
Ne pas raccorder plus d’une électrode ou plus d’un câble de  
masse à une même borne de sortie de soudage.  
OM-1500-19 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Il reste une TENSION DC NON NÉGLIGEABLE dans  
les sources de soudage onduleur quand on a  
coupé l’alimentation.  
LE SOUDAGE peut provoquer un in  
cendie ou une explosion.  
Le soudage effectué sur des conteneurs fermés tel  
que des réservoirs, tambours ou des conduites peu  
provoquer leur éclatement. Des étincelles peuven  
D
Arrêter les convertisseurs, débrancher le courant électrique et  
déchargerles condensateurs d’alimentation selon les instructions  
indiquées dans la partie Entretien avant de toucher les pièces.  
être projetées de l’arc de soudure. La projection d’étincelles, des pièce  
chaudes et des équipements chauds peut provoquer des incendies e  
des brûlures. Le contact accidentel de l’électrode avec des objet  
métalliquespeut provoquer des étincelles, une explosion, un surchauf  
fement ou un incendie. Avant de commencer le soudage, vérifier e  
s’assurer que l’endroit ne présente pas de danger.  
DES PIÈCES CHAUDES peuvent  
provoquer des brûlures graves.  
D
Ne pas toucher à mains nues les parties  
chaudes.  
D
Prévoir une période de refroidissement avant de  
travailler à l’équipement.  
D
Déplacer toutes les substances inflammables à une distance de  
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir  
soigneusementavec des protections homologués.  
D
Ne pas toucher aux pièces chaudes, utiliser les outils recomman-  
dés et porter des gants de soudage et des vêtements épais pour  
éviter les brûlures.  
D
D
D
Ne pas souder dans un endroit là où des étincelles peuvent tomber  
sur des substances inflammables.  
Se protéger et d’autres personnes de la projection d’étincelles et  
de métal chaud.  
LES FUMÉES ET LES GAZ peuvent être  
dangereux.  
Des étincelles et des matériaux chauds du soudage peuvent  
facilement passer dans d’autres zones en traversant de petites  
fissures et des ouvertures.  
Le soudage génère des fumées et des gaz. Leur  
inhalationpeut être dangereux pour votre santé.  
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à  
proximité.  
D
D
Eloigner votre tête des fumées. Ne pas respirer les fumées.  
À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au  
niveau de l’arc pour l’évacuation des fumées et des gaz de soudage.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de l’autre côté.  
Ne pas effectuer le soudage sur des conteneurs fermés tels que  
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été  
préparés correctement conformément à AWS F4.1 (voir les nor-  
mes de sécurité).  
D
D
Si la ventilation est médiocre, porter un respirateur anti-vapeurs  
approuvé.  
Lire et comprendre les spécifications de sécurité des matériaux  
(MSDS) et les instructions du fabricant concernant les métaux, les  
consommables, les revêtements, les nettoyants et les dégrais-  
seurs.  
D
D
Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou va-  
peurs inflammables (vapeur d’essence, par exemple).  
Brancher le câble de masse sur la pièce le plus près possible de la  
zone de soudage pour éviter le transport du courant sur une  
longue distance par des chemins inconnus éventuels en provo-  
quant des risques d’électrocution, d’étincelles et d’incendie.  
D
Travailler dans un espace fermé seulement s’il est bien ventilé ou  
en portant un respirateur à alimentation d’air. Demander toujours à  
un surveillant dûment formé de se tenir à proximité. Des fumées et  
des gaz de soudage peuvent déplacer l’air et abaisser le niveau  
d’oxygène provoquant des blessures ou des accidents mortels.  
S’assurer que l’air de respiration ne présente aucun danger.  
D
D
D
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-  
lées.  
D
D
Ne pas souder dans des endroits situés à proximité d’opérations  
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et  
les rayons de l’arc peuvent réagir en présence de vapeurs et for-  
mer des gaz hautement toxiques et irritants.  
En cas de non utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection dépourvus d’huile tels que des  
gants en cuir, une chemise en matériau lourd, des pantalons sans  
revers, des chaussures hautes et un couvre chef.  
Ne pas souder des métaux munis d’un revêtement, tels que l’acier  
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-  
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit  
bien ventilé, et en portant un respirateur à alimentation d’air. Les  
revêtementset tous les métaux renfermant ces éléments peuvent  
dégager des fumées toxiques en cas de soudage.  
D
D
D
D
D
D
Avant de souder, retirer toute substance combustible de vos po-  
ches telles qu’un allumeur au butane ou des allumettes.  
Une fois le travail achevé, assurezvous qu’il ne reste aucune  
trace d’étincelles incandescentes ni de flammes.  
Utiliser exclusivement des fusibles ou coupecircuits appropriés.  
Ne pas augmenter leur puissance; ne pas les ponter.  
LES RAYONS DE L’ARC peuvent pro  
voquer des brûlures dans les yeux e  
sur la peau.  
Une fois le travail achevé, assurezvous qu’il ne reste aucune  
trace d’étincelles incandescentes ni de flammes.  
Le rayonnement de l’arc du procédé de soudage  
génère des rayons visibles et invisibles intense  
Utiliser exclusivement des fusibles ou coupecircuits appropriés.  
Ne pas augmenter leur puissance; ne pas les ponter.  
(ultraviolets et infrarouges) susceptibles de provoquer des brûlure  
dans les yeux et sur la peau. Des étincelles sont projetées pendant le  
soudage.  
Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et  
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un  
extincteur à proximité.  
D
Porter un casque de soudage approuvé muni de verres filtrants  
approprié pour protéger visage et yeux pendant le soudage  
(voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
DES PIECES DE METAL ou DES SA-  
LETES peuvent provoquer des bles-  
sures dans les yeux.  
D
D
Porter des lunettes de sécurité avec écrans latéraux même sous  
votre casque.  
Avoir recours à des écrans protecteurs ou à des rideaux pour  
protéger les autres contre les rayonnements les éblouissements  
et les étincelles ; prévenir toute personne sur les lieux de ne pas  
regarder l’arc.  
D
Le soudage, l’écaillement, le passage de la pièce à la brosse en  
fil de fer, et le meulage génèrent des étincelles et des particules  
métalliquesvolantes. Pendant la période de refroidissement des  
soudures, elles risquent de projeter du laitier.  
Porter des lunettes de sécurité avec écrans latéraux ou un écran  
facial.  
D
Porter des vêtements confectionnés avec des matières résistan-  
tes et ignifuges (cuir, coton lourd ou laine) et des bottes de  
protection.  
D
OM-1500-19 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,  
des chocs mécaniques, des dommages physiques, du laitier, des  
flammes ouvertes, des étincelles et des arcs.  
LES ACCUMULATIONS DE GAZ  
risquent de provoquer des blessures  
ou même la mort.  
Placer les bouteilles debout en les fixant dans un support station-  
naire ou dans un porte-bouteilles pour les empêcher de tomber ou  
de se renverser.  
D
Fermer l’alimentation du gaz protecteur en cas  
de non-utilisation.  
D
Veiller toujours à bien aérer les espaces confi-  
nés ou se servir d’un respirateur d’adduction  
d’air homologué.  
Tenir les bouteilles éloignées des circuits de soudage ou autres  
circuits électriques.  
LES CHAMPS MAGNETIQUES peuv-  
ent affecter des implants médicaux.  
D
D
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
D
Porteur de simulateur cardiaque ou autre im-  
plants médicaux, rester à distance.  
Une électrode de soudage ne doit jamais entrer en contact avec  
une bouteille.  
D
Les porteurs d’implants doivent d’abord consulter leur médecin  
avant de s’approcher des opérations de soudage à l’arc, de sou-  
dage par points, de gougeage, du coupage plasma ou de chauf-  
fage par induction.  
D
D
Ne jamais souder une bouteille pressurisée risque d’explosion.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifique ;  
les maintenir ainsi que les éléments associés en bon état.  
LE BRUIT peut endommager l’ouïe.  
Le bruit des processus et des équipements peut  
affecter l’ouïe.  
D
D
D
D
Détourner votre visage du détendeur-régulateur lorsque vous  
ouvrez la soupape de la bouteille.  
D
Porter des protections approuvées pour les  
oreilles si le niveau sonore est trop élevé.  
Le couvercle du détendeur doit toujours être en place, sauf lorsque  
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.  
LES BOUTEILLES peuvent exploser  
si elles sont endommagées.  
Utiliser les équipements corrects, les bonnes procédures et suffi-  
samment de personnes pour soulever et déplacer les bouteilles.  
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de  
gaz font normalement partie du procédé de sou-  
Lire et suivre les instructions sur les bouteilles de gaz comprimé,  
l’équipement connexe et le dépliant P-1 de la CGA (Compressed  
Gas Association) mentionné dans les principales normes de sécu-  
rité.  
dage, les manipuler avec précaution.  
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance  
Risque D’INCENDIE OU D’EXPLO-  
SION.  
LES ÉTINCELLES VOLANTES ris-  
quent de provoquer des blessures.  
D
Ne pas placer l’appareil sur, au-dessus ou  
à proximité de surfaces inflammables.  
D
Porter un écran facial pour protéger le visage et  
les yeux.  
D
Ne pas installer l’appareil à proximité de pro-  
duits inflammables.  
D
Affûter l’électrode au tungstène uniquement à la  
meuleuse dotée de protecteurs. Cette manœuv-  
re est à exécuter dans un endroit sûr lorsque l’on  
porte l’équipement homologué de protection du  
visage, des mains et du corps.  
D
Ne pas surcharger l’installation électrique s’assurer que  
l’alimentationest correctement dimensionnée et protégée avant  
de mettre l’appareil en service.  
D
Les étincelles risquent de causer un incendie éloigner toute sub-  
stance inflammable.  
LA CHUTE DE L’APPAREIL peut  
blesser.  
D
Utiliser l’anneau de levage uniquement pour  
soulever l’appareil, NON PAS les chariots, les  
bouteilles de gaz ou tout autre accessoire.  
Utiliser un équipement de levage de capacité  
suffisante pour lever l’appareil.  
LES CHARGES ÉLECTROSTATI-  
QUES peuvent endommager les  
circuits imprimés.  
D
D
Établir la connexion avec la barrette de terre  
avant de manipuler des cartes ou des pièces.  
D
En utilisant des fourches de levage pour déplacer l’unité, s’assu-  
rer que les fourches sont suffisamment longues pour dépasser  
du côté opposé de l’appareil.  
D
Utiliser des pochettes et des boîtes antistati-  
ques pour stocker, déplacer ou expédier des  
cartes de circuits imprimes.  
L’EMPLOI EXCESSIF peut SUR-  
CHAUFFER L’ÉQUIPEMENT.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Prévoir une période de refroidissement ; re-  
specter le cycle opératoire nominal.  
D
Ne pas s’approcher des organes mobiles.  
Ne pas s’approcher des points de coincement  
tels que des rouleaux de commande.  
D
Réduire le courant ou le facteur de marche  
avant de poursuivre le soudage.  
D
D
Ne pas obstruer les passages d’air du poste.  
OM-1500-19 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LES FILS DE SOUDAGE peuvent  
provoquer des blessures.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
D
Ne pas appuyer sur la gâchette avant d’en  
avoir reçu l’instruction.  
D
Le rayonnement haute fréquence (H.F.) peut  
provoquer des interférences avec les équipe-  
ments de radionavigation et de communica-  
tion, les services de sécurité et les ordinateurs.  
D
Ne pas diriger le pistolet vers soi, d’autres per-  
sonnes ou toute pièce mécanique en enga-  
geant le fil de soudage.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner l’installa-  
tion.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
D
L’utilisateur est tenu de faire corriger rapidement par un électricien  
qualifié les interférences résultant de l’installation.  
Si le FCC signale des interférences, arrêter immédiatement l’ap-  
pareil.  
D
S’abstenirde toucher des organes mobiles tels  
que des ventilateurs.  
D
Maintenirfermés et verrouillés les portes, pan-  
neaux, recouvrements et dispositifs de protec-  
tion.  
LE SOUDAGE À L’ARC risque de  
provoquer des interférences.  
D
D
Seules des personnes qualifiées sont autorisées à enlever les  
portes, panneaux, recouvrements ou dispositifs de protection  
pour l’entretien.  
D
L’énergie électromagnétique risque de provo-  
quer des interférences pour l’équipement élec-  
tronique sensible tel que les ordinateurs et l’é-  
quipement commandé par ordinateur tel que  
les robots.  
Remettreles portes, panneaux, recouvrements ou dispositifs de  
protection quand l’entretien est terminé et avant de rebrancher  
l’alimentation électrique.  
D
Veiller à ce que tout l’équipement de la zone de soudage soit  
compatibleélectromagnétiquement.  
D
Pour réduire la possibilité d’interférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser  
aussi bas que possible (ex. par terre).  
Veiller à souder à une distance de 100 mètres de tout équipe-  
ment électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode d’emploi.  
En cas d’interférences après avoir pris les mesures précéden-  
tes, il incombe à l’utilisateur de prendre des mesures supplé-  
mentairestelles que le déplacement du poste, l’utilisation de câ-  
bles blindés, l’utilisation de filtres de ligne ou la pose de protec-  
teurs dans la zone de travail.  
LIRE LES INSTRUCTIONS.  
D
Lisez le manuel d’instructions avant l’utilisation  
ou la maintenance de l’appareil.  
D
D
D
D
N’utiliser que les pièces de rechange recom-  
mandées par le constructeur.  
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.  
D
Maintenir soigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une distan-  
ce correcte et utiliser une terre et un blindage pour réduire les  
interférences éventuelles.  
2-4. Proposition californienne 65 Avertissements  
Pour les moteurs à essence :  
Les équipements de soudage et de coupage produisent des  
fumées et des gaz qui contiennent des produits chimiques  
dont l’État de Californie reconnaît qu’ils provoquent des mal-  
formations congénitales et, dans certains cas, des cancers.  
(Code de santé et de sécurité de Californie, chapitre 25249.5  
et suivants)  
Les gaz d’échappement des moteurs contiennent des pro-  
duits chimiques dont l’État de Californie reconnaît qu’ils  
provoquent des cancers et des malformations congénitales  
ou autres problèmes de procréation.  
Pour les moteurs diesel :  
Les batteries, les bornes et autres accessoires contiennent  
du plomb et des composés à base de plomb, produits chimi-  
ques dont l’État de Californie reconnaît qu’ils provoquent des  
cancers et des malformations congénitales ou autres  
problèmesde procréation. Se laver les mains après manipu-  
lation.  
Les gaz d’échappement des moteurs diesel et certains de  
leurs composants sont reconnus par l’État de Californie com-  
me provoquant des cancers et des malformations  
congénitalesou autres problèmes de procréation.  
OM-1500-19 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-5. Principales normes de sécurité  
Safety inWelding, Cutting, and Allied Processes, ANSI Standard Z49.1,  
de Global Engineering Documents (téléphone : 1-877-413-5184, site  
Internet : www.global.ihs.com).  
L4W 5NS (téléphone : 800-463-6727 ou à Toronto 416-747-4044, site  
Internet : www.csa-international.org).  
Safe Practice For Occupational And Educational Eye And Face Protec-  
tion, ANSI Standard Z87.1, de American National Standards Institute,  
11 West 43rd Street, New York, NY 10036-8002 (téléphone :  
212-642-4900,site Internet : www.ansi.org).  
RecommendedSafe Practices for the Preparation for Welding and Cut-  
ting of Containers and Piping, American Welding Society Standard  
AWS F4.1 de Global Engineering Documents (téléphone  
1-877-413-5184,site Internet : www.global.ihs.com).  
:
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, de National Fire Protection Association,  
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,  
site Internet : www.nfpa.org).  
National Electrical Code, NFPA Standard 70, de National Fire Protec-  
tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (téléphone :  
617-770-3000, site Internet : www.nfpa.org).  
OSHA, Occupational Safety and Health Standards for General Indus-  
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,  
and Part 1926, Subpart J, de U.S. Government Printing Office, Superin-  
tendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954  
(téléphone: 1-866-512-1800) (il y a 10 bureaux régionaux−−le télépho-  
ne de la région 5, Chicago, est 312-353-2220, site Internet :  
www.osha.gov).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chan-  
tilly, VA 20151 (téléphone  
www.cganet.com).  
:
703-788-2700, site Internet  
:
Code for Safety in Welding and Cutting, CSA Standard W117.2, de  
CanadianStandards Association, 5060 Mississauga, Ontario, Canada  
2-6. Information EMF  
Considérationssur le soudage et les effets de basse fréquence et des  
champs magnétiques et électriques.  
1. Garder les câbles ensemble, les torsader, les scotcher, ou les  
recouvrir d’une housse.  
2. Disposer les câbles d’un côté et à distance de l’opérateur.  
3. Ne pas courber pas et ne pas entourer pas les câbles autour de  
votre corps.  
Le courant de soudage, pendant son passage dans les câbles de sou-  
dage, causera des champs électromagnétiques. Il y a eu et il y a encore  
un certain souci à propos de tels champs. Cependant, après avoir exa-  
miné plus de 500 études qui ont été faites pendant une période de  
recherche de 17 ans, un comité spécial ruban bleu du National  
Research Council a conclu : « L’accumulation de preuves, suivant le  
jugement du comité, n’a pas démontré que l’exposition aux champs  
magnétiqueset champs électriques à haute fréquence représente un  
risque à la santé humaine ». Toutefois, des études sont toujours en  
cours et les preuves continuent à être examinées. En attendant que les  
conclusions finales de la recherche soient établies, il vous serait  
souhaitablede réduire votre exposition aux champs électromagnéti-  
ques pendant le soudage ou le coupage.  
4. Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
5. Connecter la pince sur la pièce aussi près que possible de la  
soudure.  
En ce qui concerne les implants médicaux :  
Les porteurs d’implants doivent d’abord consulter leur médecin avant  
de s’approcher des opérations de soudage à l’arc, de soudage par  
points, de gougeage, du coupage plasma ou de chauffage par induc-  
tion. Si le médecin approuve, il est recommandé de suivre les  
procédures précédentes.  
Pour réduire les champs magnétiques sur le poste de travail, appliquer  
les procédures suivantes :  
OM-1500-19 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
OM-1500-19 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3 DEFINITIONS  
3-1. Warning Label Definitions  
Warning! Watch Out! There are  
possible hazards as shown by the  
symbols.  
Drive rolls can injure fingers  
Welding wire and drive parts are at  
welding voltage during operation −  
keep hands and metal objects  
clear.  
1
Electric shock can kill.  
1.1 Wear dry insulating gloves.  
Do not touch electrode with  
bare hand. Do not wear wet or  
damaged gloves.  
1
2
1.1  
2.1  
1.2  
1.3  
1.2 Protect yourself from electric  
shock by insulating yourself  
from work and ground.  
1.3 Disconnect input plug or  
power before working on  
machine.  
2
Breathing welding fumes can  
be hazardous to your health.  
2.2  
2.3  
2.1 Keep your head out of the  
fumes.  
2.2 Use forced ventilation or local  
exhaust to remove the fumes.  
2.3 Use ventilating fan to remove  
fumes.  
3
4
5
3.1  
4.1  
3.2  
3.3  
3
Welding sparks can cause  
explosion or fire.  
3.1 Keep flammables away from  
welding. Don’t weld near  
flammables.  
3.2 Welding sparks can cause  
fires. Have a fire extinguisher  
nearby and have a watch  
person ready to use it.  
+ + +  
3.3 Do not weld on drums or any  
closed containers.  
6
4
Arc rays can burn eyes and  
injure skin.  
+
4.1 Wear hat and safety glasses.  
Use ear protection and button  
shirt collar. Use welding  
helmet with correct shade of  
filter. Wear complete body  
protection.  
S-178 936  
5
Become trained and read the  
instructions before working on  
the machine or welding.  
6
Do not remove or paint over  
(cover) the label.  
OM-1500-19 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-2. Manufacturer’s Rating Label For CE Products  
S/N:  
U1  
I =  
1
DC  
IP 23  
Hz  
110 V  
=
10.0  
A
U =  
2
I =  
425 A  
2
110 V  
X 60 %  
Ref. 181 678 / 804 005-A  
3-3. WEEE Label (For Products Sold Within The EU)  
Do not discard product (where ap-  
plicable) with general waste.  
Reuse or recycle Waste Electrical  
and Electronic Equipment (WEEE)  
by disposing at a designated collec-  
tion facility.  
Contact your local recycling office  
or your local distributor for further  
information.  
OM-1500-19 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-4. Symbols And Definitions  
. Some symbols are found only on CE products.  
Output  
Input  
Amperes  
Percent  
Volts  
V
IP  
A
Degree Of Protec-  
tion  
Duty Cycle  
Wire Feed  
X
Cold Jog (Inch) To-  
wards Workpiece  
Input  
Purge By Gas  
Fast  
Slow  
Constant Current  
Trigger Hold Off  
Circuit Breaker  
Trigger Hold On  
Constant Voltage  
Rated Welding  
Current  
Increase  
I2  
U2  
Conventional Load  
Voltage  
Read Instructions  
Primary Voltage  
Hertz  
U1  
Hz  
Primary Current  
I1  
Notes  
OM-1500-19 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 4 INSTALLATION  
4-1. Specifications  
Welding  
Type of  
Input  
Wire Feed  
Speed  
Range  
Wire  
Diameter  
Range  
Max. Wire  
Spool  
Capacity  
Power  
Welding  
Circuit  
Rating  
IP  
Rating  
Overall  
Dimensions  
Input  
Weight  
Source  
Power  
Type  
*Solid Steel:  
.023 .062 in  
(0.6 1.6 mm);  
Stainless Steel:  
.023 .052 in  
Length: 21 in  
(533 mm)  
Constant  
50 780 ipm  
(1.3 19.8  
mpm)  
Voltage (CV)  
Or Constant  
Current (CC)  
DC Power  
Open-Circuit/  
Arc Voltage,  
14 110  
425 Amperes  
At 60%  
Duty Cycle  
45 lb (20.4 kg),  
12 in (304 mm)  
Width: 9 in  
(229 mm)  
35 lb  
(16 kg)  
23  
Depending On (0.6 1.3 mm);  
Volts DC  
Height: 15-1/2 in  
(394 mm)  
Arc Voltage  
Flux Cored:  
.030 .062 in  
(0.8 1.6 mm)  
Source Only  
*Maximum gun length is 10 ft. for solid steel .062 in. wire.  
4-2. Gun Recommendation Table  
Process  
Gun  
GMAW Hard or Corded Wires  
FCAW Self-Shielding Wires  
Bernard Q - 4015  
FC-1260  
Dura-Flux  
Notes  
OM-1500-19 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-3. Equipment Connection Diagram  
Turn Off wire feeder and  
welding power source. Stop  
engine  
on  
welding  
generator.  
1
Use only with CC/CV DC  
Power Sources.  
1
Constant Current (CC) or  
Constant Voltage (CV)  
Welding Power Supply  
10  
2
3
Weld Cable To Feeder  
Ground Cable To Workpiece  
Weld cable and ground cable con-  
nections to power source (DCEN/  
DCEP) are dependant on wire type.  
. Since feeder is not polarity sen-  
sitive, there is no need for an  
electrode polarity switch.  
4
5
Workpiece  
Voltage Sensing Clamp  
2
Connect voltage sensing clamp to  
workpiece.  
9
8
6
7
8
9
Gun  
3
Gun Trigger Receptacle  
Wire Feeder  
Gas Hose  
7
10 Gas Cylinder  
Use of shielding gas is dependant  
on wire type.  
4
5
. Shielding gas pressure not to  
exceed 100 psi (689 kPa).  
6
Ref. 804 000-C  
Notes  
OM-1500-19 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-4. Installing And Aligning Wire Guide And Drive Rolls  
Installing Wire Guide And Drive  
Rolls:  
1
2
Drive Roll Nut  
Drive Roll Carrier  
Turn nut one click until lobes of nut  
line up with lobes of drive roll carrier.  
3
Drive Roll  
Slide drive roll onto drive roll carrier.  
Turn nut one click.  
Repeat procedure for top drive roll.  
4
5
Inlet Wire Guide Screw  
Inlet Wire Guide  
(One Piece Anti-wear)  
. The factory installed inlet wire  
guide is good for up to 5/64  
inch diameter wire.  
Installing Wire Guide  
And Drive Rolls  
Loosen securing screw. Align inlet  
guide so inlet guide screw is  
centeredin groove in guide, or so tip  
is as close to drive rolls as possible  
without touching. Tighten screw.  
Aligning Wire Guide And Drive  
Rolls:  
5
View is from top of drive rolls look-  
ing down with pressure assembly  
open.  
4
3
6
7
8
9
Drive Roll Securing Nut  
Drive Roll  
Wire Guide  
Welding Wire  
10 Drive Gear  
1
Turn screw in or out until drive roll  
groove lines up with wire guide.  
2
Close pressure roll assembly.  
Only bottom drive roll alignment is  
adjustable. Turn adjustment screw  
in or out until groove in drive roll  
lines up with wire guide as shown.  
Aligning Wire Guide And Drive Rolls  
Cleaning Drive Rolls:  
Remove drive rolls, and clean  
grooves using a wire brush.  
Correct  
Incorrect  
8
9
7
6
10  
Tools Needed:  
3/16 in  
Ref. 804 001-B  
OM-1500-19 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-5. Connecting Welding Gun And Voltage Sensing Clamp  
Turn Off wire feeder and  
welding power source. Stop  
engine on welding  
generator.  
1
2
3
Gun Securing Knob  
Gun Block  
2
1
Gun Outlet Wire Guide  
Loosen knob, insert gun end into  
block. Position outlet wire guide as  
close as possible to drive rolls with-  
out touching. Tighten knob.  
4
5
6
Gun Trigger Plug  
Gun Trigger Receptacle  
Voltage Sensing Clamp  
Connect voltage sensing clamp to  
workpiece.  
3
Internal Side View  
4
6
5
Ref. 804 002-C  
4-6. Connecting Shielding Gas  
1
2
Gas Hose With 5/8-18  
Right-hand Thread Fittings  
(Customer Supplied)  
Shielding Gas Cylinder  
4
3
. Shielding gas pressure not to  
Rear View  
exceed 100 psi (689 kPa).  
3
4
Valve  
Flowmeter  
Close valve on cylinder when fin-  
ished welding.  
2
1
Tools Needed:  
5/8 in  
Ref. 804 003-A  
OM-1500-19 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-7. Connecting Weld Cable  
!
Turn Off wire feeder and  
welding power source. Stop  
engine on welding  
Rear View  
generator.  
1
User-Suppled Weld Cable  
Follow wire manufacturer’s recom-  
mendations for weld cable polarity.  
From Wire Feeder  
2
3
User-Suppled Male Connector  
User-Suppled Female  
Connector  
Push female connector over male  
connector, and turn 1/4 turn clock-  
wise.  
2
1
3
804 004-A  
4-8. Weld Cable Sizes  
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit  
Not Exceeding***  
Weld Output  
Terminals  
!
!
Turn off power before  
connectingto weld out-  
put terminals.  
150 ft  
(45 m)  
200 ft  
250 ft  
300 ft  
350 ft  
400 ft  
100 ft (30 m) or Less  
(60 m) (70 m) (90 m) (105 m) (120 m)  
Do not use worn, dam-  
aged, undersized, or  
poorly spliced cables.  
10 60% 60 100%  
Welding  
Amperes  
Duty  
Duty  
10 100% Duty Cycle  
Cycle  
Cycle  
100  
150  
200  
4 (20)  
3 (30)  
3 (30)  
4 (20)  
3 (30)  
2 (35)  
4 (20)  
2 (35)  
1 (50)  
3 (30)  
1 (50)  
2 (35)  
1/0 (60)  
2/0 (70)  
1 (50)  
1/0 (60)  
3/0 (95)  
1/0 (60)  
3/0 (95)  
2/0 (70)  
1/0 (60)  
3/0 (95) 4/0 (120) 4/0 (120)  
2 ea. 2/0 2 ea. 2/0  
250  
300  
350  
400  
500  
2 (35)  
1 (50)  
1 (50)  
1/0 (60)  
2/0 (70)  
3/0 (95)  
3/0 (95)  
4/0 (120)  
2/0 (70)  
3/0 (95) 4/0 (120)  
(2x70)  
(2x70)  
2 ea. 2/0 2 ea. 3/0 2 ea. 3/0  
(2x70) (2x95) (2x95)  
1/0 (60)  
2/0 (70)  
2/0 (70)  
3/0 (95)  
3/0 (95) 4/0 (120)  
2 ea. 2/0 2 ea. 3/0 2 ea. 3/0 2 ea. 4/0  
(2x70) (2x95) (2x95) (2x120)  
1/0 (60)  
1/0 (60)  
2/0 (70)  
4/0 (120)  
4/0 (120)  
2 ea. 2/0 2 ea. 3/0 2 ea. 4/0 2 ea. 4/0  
(2x70) (2x95) (2x120) (2x120)  
2 ea. 2/0 2 ea. 3/0 2 ea. 4/0 3 ea. 3/0 3 ea. 3/0  
(2x70)  
(2x95)  
(2x120)  
(3x95)  
(3x95)  
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.  
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.  
2
( ) = mm for metric use  
S-0007-F−  
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.  
OM-1500-19 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-9. Installing And Threading Welding Wire  
Installing Wire And Adjusting  
Hub Tension:  
. Hold wire tightly to keep  
1
2
Retaining Nut  
it from unraveling.  
Hub Tension Adjustment Knob  
Remove retaining ring, and install  
spool so hub pin fits spool hole. Re-  
install retaining nut.  
Adjust tension knob so only a slight  
force is needed to turn spool.  
Threading Welding Wire:  
3
Pressure Assembly  
Adjustment Knob  
Lay gun cable out straight.  
Open pressure assembly, hold wire  
tightly, and cut off end. Push wire  
through guides into gun.  
Close and tighten pressure assem-  
bly. Press jog switch until wire  
comes out gun.  
3
Feed wire against wooden surface,  
and tighten knob so wire does not  
slip.  
1
2
Cut off wire, and close door.  
6 in  
(150 mm)  
Pull and hold wire; cut off end.  
Tighten  
Clockwise  
WOOD  
Ref. 804 005-B  
OM-1500-19 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-10. Display Board (PC20) DIP Switch Settings  
DIP Switch Settings:  
Display Hold ON  
Displays will hold their last value for  
five seconds after the trigger is re-  
leased. After the hold times out, the  
Voltage Display will show open circuit  
voltage. If the Wire Speed / Amps  
Display is set to display Amps, the  
amperage value will hold, after the  
hold times out, preset Wire Speed will  
be displayed.  
1
2
3
4
5
Display Hold OFF  
Displays will not hold values. Immedi-  
ately, when the trigger is released,  
the Voltage Display will show open  
circuit voltage. The Wire Speed /  
Amps Display will display preset Wire  
Speed when the trigger is released.  
1
2
3
4
5
Do Not Display Amperage  
1
2
3
4
5
Wire Speed / Amps Display will dis-  
play only Wire Speed.  
1
1
2
2
3
3
4
4
5
5
DIP Switch Factory Settings  
Display Amperage  
Wire Speed / Amps Display will dis-  
play Amps while welding and Wire  
Speed while not welding. If the hold  
function is enabled, Amps will be dis-  
played during hold also.  
Indicates Switch does not Affect This Function  
Wire Speed - Inches Per Minute  
Displays Wire Speed in Inches per  
Minute.  
1
1
2
2
3
3
4
4
5
5
Wire Speed - Meters Per Minute  
Displays Wire Speed in Meters per  
Minute.  
Information OFF  
Information is not displayed.  
1
1
2
2
3
3
4
4
5
5
Information ON  
With switch in ON position, at feeder  
power up, feeder will display various  
sets of information. Each set of infor-  
mationwill be displayed for three sec-  
onds.  
. DIP switch is located  
behind front panel as  
shown.  
Display Board (PC20) Software  
Part Number −  
Top display will show the first three  
digits, bottom display will show last  
three digits of the Display board  
(PC20) software revision level.  
Motor Board (PC1) Software Part  
Number −  
Top display will show the first three  
digits, bottom display will show last  
three digits, of the Motor board (PC1)  
software revision level.  
Ref. 804 006-A  
Accumulated Weld Time −  
This is the time the feeder has actual-  
ly been used for welding. This infor-  
mation will be displayed in two  
halves. First being years and days,  
second in hours and minutes. Top  
display will show years/hours, bot-  
tom display will show days/minutes.  
OM-1500-19 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 5 OPERATION  
5-1. Controls With Meters  
1
2
Power Control Switch  
Trigger Hold Switch  
2
Trigger hold allows operator to weld without  
holding gun trigger.  
OFF  
3
1
To use trigger hold function, place trigger  
hold switch in the ON position.  
The operator must hold the trigger for a mini-  
mum of 2 seconds, but no longer than 6 sec-  
onds before releasing it. Welding will contin-  
ue when trigger is released.  
4
5
To stop welding, press and release the trig-  
ger.  
3
Jog/Purge Switch  
Pressing the Jog switch allows the operator  
to jog wire without energizing the contactor  
or gas valve.  
Pressing the Purge switch allows the opera-  
tor to purge gas lines before welding and to  
preset gas flow rate at the flowmeter.  
6
4
Voltmeter  
Displays actual arc voltage or open circuit  
voltage at the feeder.  
5
Wire Speed / Amperage Meter  
Displays wire speed in Inches per Minute. To  
display wire speed in Meters per Minute, see  
Section 4-10.  
Amperagedisplayed at the feeder is approxi-  
mate. Refer to power source for actual am-  
perage. To display Amperage, see Section  
4-10.  
6
Wire Speed Control  
Use control to adjust wire speed within the  
speed range selected by the wire speed  
range switch, located on the inner control  
panel.  
Front Panel  
7
HI/LO Speed Range Switch  
Use switch to select speed range. High  
range is 50 to 780 Inches per minute. Low  
range is approximately half of high range.  
9
7
8
8
CC/CV Switch  
Use switch to match feeder with the output of  
the power source.  
9
Soft Start Switch  
The Soft Start feature provides a smooth  
start during most weld conditions. When the  
trigger is pulled, the wire speed is approxi-  
mately 25% of the weld wire speed, as set by  
the wire speed control knob. After an arc is  
established,the wire speed increases to the  
weld wire speed.  
Internal Control Panel  
When using small diameters wire, or with in-  
verter power sources, it may be necessary to  
turn switch off to obtain smooth starts.  
After adjusting the switches, close and latch  
the door before welding.  
Internal Side View  
Ref. 804 006-B  
OM-1500-19 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-2. Controls Without Meters  
1
2
Power Control Switch  
Jog/Purge Switch  
Pressing the Jog switch allows the operator  
to jog wire without energizing the contactor  
or gas valve.  
OFF  
2
1
Pressing the Purge switch allows the opera-  
tor to purge gas lines before welding and to  
preset gas flow rate at the flowmeter.  
3
Wire Speed Control  
Use control to adjust wire speed within the  
speed range selected by the wire speed  
range switch, located on the inner control  
panel.  
4
CC/CV Switch  
Use switch to match feeder with the output of  
the power source.  
5
HI/LO Speed Range Switch  
Use switch to select speed range. High  
range is 50 to 780 Inches per minute. Low  
range is approximately half of high range.  
3
6
Soft Start Switch  
The Soft Start feature provides a smooth  
start during most weld conditions. When the  
trigger is pulled, the wire speed is approxi-  
mately 25% of the weld wire speed, as set by  
the wire speed control knob. After an arc is  
established,the wire speed increases to the  
weld wire speed.  
When using small diameters wire, or with in-  
verter power sources, it may be necessary to  
turn switch off to obtain smooth starts.  
After adjusting the switches, close and latch  
the door before welding.  
Front Panel  
6
5
4
Internal Control Panel  
Internal Side View  
Ref. 804 006-B  
OM-1500-19 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-3. Gun Consumables Information  
200 007-B  
Notes  
OM-1500-19 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-4. Wire Speed Control Settings  
Ref. 222 307A  
Notes  
OM-1500-19 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 6 MAINTENANCE & TROUBLESHOOTING  
6-1. Routine Maintenance  
!
Disconnect power  
before maintaining.  
. Maintainmore often  
during severe conditions.  
3 Months  
Replace  
Damaged Or  
Unreadable  
Labels  
Replace Damaged  
Gas Hose  
Repair Or Replace  
Cracked Cables  
And Cords  
6 Months  
Clean  
Drive  
Rolls  
Blow Out Or  
Vacuum Inside  
6-2. Overload Protection And Thermostat Protection  
Turn Off wire feeder and  
welding power source. Stop  
engine on welding  
generator.  
1
Circuit Breaker CB1  
1
CB1 protects wire feeder from over-  
load. Correct problem and reset  
CB1.  
Close and latch door.  
Thermostat Protection  
CB1  
Unit has internal thermostat protec-  
tion and will not feed wire if over-  
Internal Side View  
Ref. 804 006-B  
OM-1500-19 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6-3. Troubleshooting  
Trouble  
Remedy  
Wire does not feed; open-circuit voltage Check circuit breaker CB1. Reset CB1.  
available.  
Unit overheated. Allow unit to cool.  
Check sensing lead connection.  
Check gun trigger plug connection.  
Check gun trigger. See gun Owner’s Manual.  
Have Factory Authorized Service Agent check Control board PC1.  
Wire feeds erratically.  
Readjust hub tension.  
Readjust drive roll pressure.  
Remove weld spatter around nozzle opening.  
Replace contact tip or liner. See gun Owner’s Manual.  
Check wire drive motor brushes.  
Have Factory Authorized Service Agent check control board PC1.  
Check and replace contact tip or liner if necessary.  
Have Factory Authorized Service Agent check Control board PC1.  
If soft start is not on, motor will switch to slower speed if current is not sensed by HD1.  
When soft start is on, motor will run slow until weld current is sensed by HD1.  
Check transducer HD1 and connections, and replace if necessary.  
Motor runs slowly.  
Unit does not switch out of Soft Start.  
Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s  
but not when gun trigger is pressed.  
Manual.  
Have Factory Authorized Service Agent check Control board PC1.  
Wire stubbing on low end using a con- Make sure CC/CV switch is in CC position (see Section 5-1).  
stant current power source or feeder re-  
sets.  
Increase power source inductance setting if available.  
Increase output setting of power source or decrease wire feed speed.  
Gas does not flow or does not stop flow- Check gas valve.  
ing; wire feeds.  
Check coil voltage and connections of gas valve GS1. Check continuity of coil. Replace GS1 if necessary.  
Have Factory Authorized Service Agent check Control board PC1.  
Clear blockage in gas hose or replace hose.  
Clear blockage in welding gun.  
Wire remains energized after trigger is Check contactor W1 to see if contacts are frozen closed.  
released.  
Gun trigger is pressed, gas does not If a welding arc is not established in 3 seconds, after the gun trigger is activated, the unit will feed wire  
flow, wire is not energized, wire feeds.  
without energizing the contactor or gas valve. If the gun trigger is still activated after two minutes, the wire  
will stop feeding. This is to prevent complete despoolling of the wire, as in the case of a damaged gun.  
OM-1500-19 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Trouble  
Remedy  
Have Factory Authorized Service Agent check Control board PC1.  
Informationon display board is not accu-  
rate.  
Check transducer HD1 and connections, and replace if necessary.  
Have Factory Authorized Service Agent check Control board PC1.  
Display on display board does not light.  
Replace display board.  
Replace display board.  
Segments on the display board are  
missing.  
6-4. Diagnostics  
Error Indicators  
Shown On Display  
HLP 11  
RED LED on Motor Board PC1  
1 Blink  
Error  
Communication Error  
HLP 14  
4 Blinks  
Motor  
(Constant Blinking)  
Overload Error  
HLP 15  
3 Blinks  
Bus Bar  
Overheat Error  
Error Indications  
Error conditions are indicated by a “HLP” message on the display, or by the blinking of the Red LED on Motor  
Board PC1. To view the Red LED, turn Off power source, remove shroud, and turn power source On. The Red  
LED blinks in a 2.5 second cycle. The number of blinks in this period indicates the type of error. If an error condi-  
tion does not exist on the motor board, the Red LED is on steady.  
Communication Error  
The communication error occurs 2.5 seconds after a loss of communication between the motor board and the  
meter board. The user may continue to weld with this error. The error may be cleared by turning power Off, wait-  
ing a minimum of two seconds, and turning power On.  
Motor Overload Error  
The motor overload error can indicate that the motor has been drawing too much current for too long, To remedy  
this, reduce the wire feed speed or the wire feeder torque load/duty cycle. The error may be cleared by turning  
power Off, waiting a minimum of two seconds, and turning power On.  
Bus Bar Overheat Error  
The bus bar overheat error can be caused by the arc drawing too much current for too long. To remedy this, re-  
duce the weld amperage or duty cycle.  
OM-1500-19 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notes  
OM-1500-19 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 ELECTRICAL DIAGRAM  
218 763-E  
Figure 7-1. Circuit Diagram For Wire Feeder  
OM-1500-19 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 8 PARTS LIST  
58  
59  
34  
60  
62  
33  
18  
45  
71  
26  
54  
72  
73  
32  
31  
36  
29  
57  
16  
39  
42  
42  
61  
62  
53  
55  
44  
49  
27  
26  
28  
69  
63  
24  
23  
22  
21  
41  
42  
15  
70  
41  
43  
52  
40  
30  
17  
68  
37  
48  
46  
35  
47  
65  
25  
20  
19  
51  
68  
50  
66  
56  
38  
14  
11  
10  
13  
5
67  
64  
12  
7
8
1 (Fig 8-2)  
6
3
4
2 (Fig 8-3)  
Ref. 804 007-K  
9
Figure 8-1. Complete Assembly  
OM-1500-19 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Diagram  
marking  
Part  
No.  
Description  
Quantity  
1 . . . . . . . . . . . . . . . . . . Fig 8-2 . . Panel Assembly Front (Without Meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
2 . . . . . . . . . . . . . . . . . . Fig 8-3 . . Panel Assembly Front (With Meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
3 . . . . . . . . . . . . . . . . . 221 050 . . Case, Control Feeder Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
4 . . . . . . . . . . . . . . . . . 208 015 . . Handle, Rubberized Carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
5 . . . . . . . . . . . . . . . . . 221 051 . . Chassis, Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
6 . . . . . . . . . . . . . . . . . 138 044 . . Bushing, Strain Relief .120/.150 Id X .500 Mtg Hole . . . . . . . . . . . . . . . . . . 1  
7 . . . . . . . . . . . . . . . . . . 214 011 . . Cable, Sensing (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 600 848 . . . . Wire, Strd 12Ga Blk 600v 105C 65x30 Hyp .199Od . . . . . . . . . . . . . . . 16 ft  
. . . . . . . . . . . . . . . . . . . 208 820 . . . . Clamp, Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
8 . . . . . . . . . . . . . . . . . 221 998 . . Cable, Trigger 25 In (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG6 . . . . 115 094 . . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 049 445 . . . . Cable, Port No 18 2/C Type Sjo Nprn Jkt . . . . . . . . . . . . . . . . . . . . . . . . 3 ft  
. . . . . . . . . . RC2 . . . . 080 328 . . . . Rcpt W/Skts, Free Hanging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 048 834 . . . . Conn, Circ Cpc Clamp Str Rlf Size 11 .329 Od . . . . . . . . . . . . . . . . . . . . . 1  
9 . . . . . . . . . . . . . . . . . 070 654 . . Bushing, Strain Relief .300 Id X .550 Mtg Hole . . . . . . . . . . . . . . . . . . . . . . 1  
10 . . . . . . . . . . . . . . . . 208 076 . . Panel, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
11 . . . . . . . . . . . . . . . . 216 315 . . Nameplate, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
12 . . . . . . . CB1 . . . . 083 432 . . Circuit Breaker, Man Reset 1P 10A 250VAC Frict . . . . . . . . . . . . . . . . . . . . 1  
13 . . . . . . . . . . . . . . . . 147 195 . . Nut, 375-27 .54Hex .25h Nyl Flange .62D . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
14 . . . . S3, S5, S6 . 217 932 . . Switch, Rocker Spst .4VA 28VDC On-None-Off .187 Ter . . . . . . . . . . . . . . 3  
15 . . . . . . . PC1 . . . . 224 675 . . Circuit Card Assy, Motor Control W/Program . . . . . . . . . . . . . . . . . . . . . . . . 1  
16 . . . . . . . HD1 . . . . 218 339 . . Transducer, Current 600A Module Supply V +5V . . . . . . . . . . . . . . . . . . . . 1  
17 . . . . . . . M1 . . . . 220 195 . . Motor, Right Angle 24VDC 145 RPM 37.5 Ratio W/Plug . . . . . . . . . . . . . . 1  
18 . . . . . . . . . . . . . . . . 124 778 . . Knob, T 2.000 Bar W/.312-18 Stud 1.000 Lg Plstc . . . . . . . . . . . . . . . . . . . 1  
19 . . . . . . . . . . . . . . . . 079 634 . . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
20 . . . . . . . . . . . . . . . . 151 828 . . Pin, Cotter Hair .042 X .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
21 . . . . . . . . . . . . . . . . 085 243 . . Knob, Adjust Tension 1.250 Dia X .31218 Thrd Stl . . . . . . . . . . . . . . . . . . 1  
22 . . . . . . . . . . . . . . . . 089 477 . . Spring, Cprsn .770 Od X .100 Wire X .715 Pld . . . . . . . . . . . . . . . . . . . . . . 1  
23 . . . . . . . . . . . . . . . . 085 244 . . Washer, Cupped .328idx .812odx16gax.125 Lip . . . . . . . . . . . . . . . . . . . . . 1  
24 . . . . . . . . . . . . . . . . 089 562 . . Fastener, Pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
25 . . . . . . . . . . . . . . . . 166 071 . . Lever, Mtg Pressure Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
26 . . . . . . . . . . . . . . . . 166 072 . . Spacer, Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
27 . . . . . . . . . . . . . . . . 172 075 . . Carrier, Drive Roll W/Components 24 Pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1  
28 . . . . . . . . . . . . . . . . 602 009 . . Screw, 25020x1.25 Soc HdHex Gr8 Pln . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
29 . . . . . . . . . . . . . . . . 010 224 . . Pin, Spring Cs .187 X 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
30 . . . . . . . . . . . . . . . . 144 172 . . Ftg, Hose Brs Barbed M 3/16 Tbg X .250-20 . . . . . . . . . . . . . . . . . . . . . . . . 1  
31 . . . . . . . . . . . . . . . . 079 625 . . Washer, Wave .500idx0.750odx.015T Stl Lbs . . . . . . . . . . . . . . . . . . . . . . . 2  
32 . . . . . . . . . . . . . . . . 092 865 . . Key, Stl .1215/.1230 X .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
33 . . . . . . . . . . . . . . . . 172 076 . . Carrier, Drive Roll W/Components Keyed 24 Pitch . . . . . . . . . . . . . . . . . . . 1  
34 . . . . . . . . . . . . . . . . 121 271 . . Screw, 250-20x .50 Soc Hd-Hex Gr8 Pln Lkg Patch . . . . . . . . . . . . . . . . . . 1  
35 . . . . . . . . . . . . . . . . 098 615 . . Hose, Sae .187 Id X .410 Od X 20.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
36 . . . . . . . . . . . . . . . . 605 308 . . Ring, Rtng Ext .500 Shaft X .035 Thk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
37 . . . . . . . . . . . . . . . . 222 159 . . Spring, Torsion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
38 . . . . . . . . . . . . . . . . 222 396 . . Insulator, Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
39 . . . . . . . W1 . . . . 224 697 . . Contactor 12VDC W/Bus Bars, (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
40 . . . . . . PLG5 . . . 201 665 . . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
41 . . . . TP1, TP2 . . 230 471 . . . . Thermostat, Nc Open 140C Close 110C Snap Action . . . . . . . . . . . . . . . 2  
42 . . . . . . . . . . . . . . . . 183 387 . . . . Washer, Cone .380idx .860odx.109t Stl Pld 4000Lbs . . . . . . . . . . . . . . . 4  
43 . . . . . . . . . . . . . . . . 223 862 . . . . Nut, M10-1.5 17Hex 8H Brs Din 934 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
44 . . . . . . . . . . . . . . . . 222 001 . . Bracket, Mtg Contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
45 . . . . . . . . . . . . . . . . 221 347 . . Grommet, Bus Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
46 . . . . . . . . . . . . . . . . 600 324 . . Cable, Weld Cop Strd No 4/0 Epdm Jkt . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 in  
47 . . . . . . . . . . . . . . . . 215 980 . . Bushing, Strain Relief .709/.984 Id X1.375 Mtg Hole . . . . . . . . . . . . . . . . . 1  
48 . . . . . . . . . . . . . . . . 221 052 . . Shroud, Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-1500-19 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Diagram  
marking  
Part  
No.  
Description  
Quantity  
Figure 8-1. Complete Assembly (Continued)  
49 . . . . . . . . . . . . . . . . 207 679 . . Insert, Corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
50 . . . . . . . GS1 . . . . 226 819 . . Valve, 12VDC 1Way .75014 Thd 2mm Orf 100PSI . . . . . . . . . . . . . . . . . . 1  
51 . . . . . . . . . . . . . . . . 222 067 . . Insulator, Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
52 . . . . . . . . . . . . . . . . 070 371 . . Blank, Snap-In Nyl 1.093/1.125 Mtg Hole Black . . . . . . . . . . . . . . . . . . . . . . 1  
53 . . . . . C1, C2 . . . 200 606 . . Capacitor, Elctlt 1200 Uf 300 VDC Can 1.39 Dia . . . . . . . . . . . . . . . . . . . . . 2  
54 . . . . . . . . . . . . . . . . 210 133 . . Bracket, Capacitor Support SC12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
55 . . . . . . . . . . . . . . . . 207 678 . . Insulator, Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
56 . . . . . . . . . . . . . . . . 222 103 . . Support, Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
57 . . . . . . . . . . . . . . . . 225 069 . . Hub, Spool W/Threads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
58 . . . . . . . . . . . . . . . . 209 450 . . Nut, Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
59 . . . . . . . . . . . . . . . . 172 919 . . Knob, Brake Adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
60 . . . . . . . . . . . . . . . . 172 918 . . Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
61 . . . . . . . . . . . . . . . . 058 424 . . Washer, Fibre (Brake) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
62 . . . . . . . . . . . . . . . . 201 309 . . Washer, Anti-Turn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 223 814 . . Label, Warn Gen Precaution Suitcase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 223 815 . . Label, Warn Gen Precaution Suitcase (CE Only) . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 196 956 . . Label, Warning Electric Shock And Pinch Wordless . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 222 306 . . Label, Warning General Precautionary Static Vert . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 223 034 . . Label, Warning General Precautionary Static Vert (CE Only) . . . . . . . . . . 1  
63 . . . . . . . . . . . . . . . . 220 805 . . Nut, 750-14 Knurled 1.68Dia .41H Nyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
64 . . . . . . . . . . . . . . . . 081 895 . . Nut, 010-32 Rubber .75Dia .81l Insert In .38Hole . . . . . . . . . . . . . . . . . . . . 5  
65 . . . . . . . . . . . . . . . . 182 445 . . Nut, Conduit 1.000 Npt Pld 1.688 Od X .200 Thk . . . . . . . . . . . . . . . . . . . . 1  
66 . . . . . . . . . . . . . . . . 208 000 . . Washer, Shldr .260id 0.630odx.125t .327odx.062t Nyl . . . . . . . . . . . . . . . . 4  
67 . . . . . . . . . . . . . . . . 222 181 . . Grommet, Scr No 8/10 Panel Hole .281 Sq .031 High . . . . . . . . . . . . . . . . 5  
68 . . . . . . . . . . . . . . . . 222 294 . . Clip, Wire/Cord .380 Bundle .250Hole .105 Thk Blk . . . . . . . . . . . . . . . . . . 2  
69 . . . . . . . . . . . . . . . . . 211 989 . . Fitting, W/Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
70 . . . . . . . . . . . . . . . . 107 983 . . Blank, SnapIn Nyl .500 Mtg Hole Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
71 . . . . . . . . . . . . . . . . 221 030 . . Guide, Wire Inlet Anti-Wear One Pc (.023 To 5/64) . . . . . . . . . . . . . . . . . . . 1  
72 . . . . . . . . . . . . . . . . 234 073 . . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
73 . . . . . . . . . . . . . . . . 234 074 . . Clamp, Pin Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG10 . . . 131 052 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG22 . . . . 115 092 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG7 . . . 130 203 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG8 . . . . 115 092 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG5 . . . 201 665 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG3 . . . 130 203 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG4 . . . 131 054 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG6 . . . . 115 094 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . PLG9, 21 . . 131 055 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . PLG17 . . . 222 397 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . RC2 . . . . 080 328 . . Rcpt W/Skts, Free Hanging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1500-19 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
. Hardware is common and  
not available unless listed.  
6
7
5
1
4
3
2
Ref. 804 007-K  
Figure 8-2. Front Panel Assembly without Meters  
Item  
No.  
Dia.  
Mkgs  
.
Part  
No.  
Description  
Quantity  
. . 1 . . . . . . . . . . . . . 171 007 . . Knob, Pointer 1.670 Dia X .250 Id W/Set ScrewSplstc . . . . . . . . . . . . . . . . . 1  
. . 2 . . . . . S1 . . . . 111 997 . . Switch, Rocker SPST 10A 250VAC OnOff Visi Red Rock . . . . . . . . . . . . . 1  
. . 3 . . . . . . . . . . . . . 222 797 . . Blank, SnapIn Nyl Rect Mtg Hole Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 4 . . . . . S2 . . . . 216 295 . . Switch, Rocker SPDT .4VA 28VDC (On)Off(On) .187T . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Without Meters (Order By Model And Serial Number) . . . . . . . 1  
. . 6 . . . . . . . . . . . . . 220 442 . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 7 . . . . . R1 . . . . 208 399 . . Pot, Cp Std Slot 1T 2. W 10K Linear W/Frict Tabs . . . . . . . . . . . . . . . . . . . . . 1  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1500-19 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
. Hardware is common and  
not available unless listed.  
6
7
5
1
4
3
2
Ref. 804 007-K  
Figure 8-3. Front Panel Assembly with Meters  
Item  
No.  
Dia.  
Mkgs  
.
Part  
No.  
Description  
Quantity  
. . 1 . . . . . . . . . . . . . 179 851 . . Knob, Pointer 1.670 Dia X .250 Id Push On W/Spring . . . . . . . . . . . . . . . . . . 1  
. . 2 . . . . . S1 . . . . 111 997 . . Switch, Rocker SPST 10A 250VAC OnOff Visi Red Rock . . . . . . . . . . . . . 1  
. . 3 . . . . . S4 . . . . 217 932 . . Switch, Rocker SPST .4VA 28VDC OnNoneOff .187 Ter . . . . . . . . . . . . . 1  
. . 4 . . . . . S2 . . . . 216 295 . . Switch, Rocker SPDT .4VA 28VDC (On)Off(On) .187T . . . . . . . . . . . . . . 1  
. . 5 . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, With Meters (Order By Model And Serial Number) . . . . . . . . . . 1  
. . 6 . . . . . . . . . . . . . 220 442 . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 7 . . . PC20 . . . 226 373 . . Circuit Card Assy, Meter Suitcase W/Program . . . . . . . . . . . . . . . . . . . . . . . . 1  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1500-19 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 8-1. Drive Roll & Wire Guide Kits (2 Drive Roll)  
. Base selection of drive rolls upon the following recommended usages:  
1. V-Grooved rolls for hard wire.  
2. U-Grooved rolls for soft and soft shelled cored wires.  
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).  
4. V-Knurled rolls for hard shelled cored wires.  
5. Drive roll types may be mixed to suit particular requirements (example:  
V-Knurled roll in combination with U-Grooved).  
Drive Roll  
Part No.  
Wire Diameter  
Kit No.  
Inlet Wire  
Guide  
Fraction  
.023/.025 in  
.030 in  
Decimal  
.023/.025 in  
.030 in  
Metric  
0.6 mm  
0.8 mm  
0.9 mm  
1.0 mm  
1.2 mm  
1.3 mm  
1.6 mm  
Type  
087 131  
079 594  
079 595  
161 189  
079 596  
079 597  
079 598  
087 130  
053 695  
053 700  
053 696  
053 697  
053 698  
053 699  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
056 192  
056 192  
056 192  
056 192  
056 193  
056 193  
056 195  
.035 in  
.035 in  
.040 in  
.040 in  
.045 in  
.045 in  
.052 in  
.052 in  
1/16 in  
.062 in  
.035 in  
.045 in  
.052 in  
.035 in  
.045 in  
.052 in  
0.9 mm  
1.2 mm  
1.3 mm  
044 749  
079 599  
079 600  
072 000  
053 701  
053 702  
U-Grooved  
U-Grooved  
U-Grooved  
056 192  
056 193  
056 193  
1/16 in  
5/64 in  
.062 in  
.079 in  
1.6 mm  
2.0 mm  
079 601  
079 602  
053 706  
053 704  
U-Grooved  
U-Grooved  
056 195  
056 195  
.035 in  
.035 in  
0.9 mm  
079 606  
132 958  
V-Knurled  
056 192  
.045 in  
.052 in  
.045 in  
.052 in  
1.2 mm  
1.3 mm  
1.6 mm  
1.8 mm  
079 607  
079 608  
079 609  
089 984  
132 957  
132 956  
132 955  
132 959  
V-Knurled  
V-Knurled  
V-Knurled  
V-Knurled  
056 193  
056 193  
056 195  
056 195  
1/16 in  
.062 in  
.068-.072 in  
.068-.072  
5/64 in  
.079 in  
2.0 mm  
079 610  
132 960  
V-Knurled  
056 195  
.045 in  
.052 in  
1/16 in  
5/64 in  
.045 in  
.052 in  
.062 in  
.079 in  
1.2 mm  
1.3 mm  
1.6 mm  
2.0 mm  
083 318  
083 317  
079 614  
079 615  
083 489  
083 490  
053 708  
053 710  
U-Cogged  
U-Cogged  
U-Cogged  
U-Cogged  
056 193  
056 193  
056 195  
056 195  
S-0859  
OM-1500-19 Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
Start Your Professional  
Welding Career Now!  
Over 80,000 trained  
since 1930!  
400 Trade Square East, Troy, Ohio 45373  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
SOCKET/WRENCH SELECTION TABLE  
(U.S. STANDARD)  
SOCKET/WRENCH SELECTION TABLE  
(METRIC)  
Specifications  
Bolt Decimal  
Socket or Wrench Size  
Specifications  
U.S.  
Socket or Wrench Size  
Bolt  
Bolt  
Nut  
Decimal  
Bolt  
Nut  
Diameter Equivalent  
Diameter  
Equivalent  
1/4 in  
5/16 in  
3/8 in  
7/16 in  
1/2 in  
9/16 in  
5/8 in  
3/4 in  
7/8 in  
1 in  
.250 in  
.3125 in  
.375 in  
.4375 in  
.500 in  
.5625 in  
.625 in  
.750 in  
.875 in  
1.000 in  
3/8 in  
1/2 in  
7/16 in  
9/16 in  
5/8 in  
6 mm  
8 mm  
.2362 in  
.3150 in  
.3937 in  
.4724 in  
.5512 in  
.6299 in  
.7087 in  
.8661 in  
.9449 in  
10 mm  
14 mm  
17 mm  
19 mm  
22 mm  
24 mm  
27 mm  
32 mm  
36 mm  
10 mm  
14 mm  
17 mm  
19 mm  
22 mm  
24 mm  
27 mm  
32 mm  
36 mm  
9/16 in  
5/8 in  
10 mm  
12 mm  
14 mm  
16 mm  
18 mm  
22 mm  
24 mm  
3/4 in  
3/4 in  
13/16 in  
7/8 in  
7/8 in  
15/16 in  
1-1/8 in  
1-5/16 in  
1-1/2 in  
1 in  
1-1/8 in  
1-5/16 in  
1-1/2 in  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
MATERIAL THICKNESS GAUGE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 2007  
(Equipment with a serial number preface of “LH” or newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to  
its original retail purchaser that new Miller equipment sold after  
the effective date of this limited warranty is free of defects in  
material and workmanship at the time it is shipped by Miller. THIS  
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
Induction Heating Coils and Blankets, Cables, and  
Non-Electronic Controls  
APT & SAF Model Plasma Cutting Torches  
Remote Controls  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
*
Accessory (Kits)  
Replacement Parts (No labor)  
Spoolmate Spoolguns  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to such  
defects in material or workmanship. Miller must be notified in  
writing within thirty (30) days of such defect or failure, at which  
time Miller will provide instructions on the warranty claim  
procedures to be followed.  
Your distributor also gives  
you ...  
Miller’s True Blue® Limited Warranty shall not apply to:  
Service  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings, relays  
or parts that fail due to normal wear. (Exception:  
brushes, slip rings, and relays are covered on Bobcat,  
Trailblazer, and Legend models.)  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment listed  
below in the event of such a failure within the warranty time  
periods. All warranty time periods start on the delivery date of the  
equipment to the original end-user purchaser, and not to exceed  
one year after the equipment is shipped to a North American  
distributor or eighteen months after the equipment is shipped to  
an International distributor.  
2. Items furnished by Miller, but manufactured by others, such  
as engines or trade accessories. These items are covered  
by the manufacturer’s warranty, if any.  
Support  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
3. Equipment that has been modified by any party other than  
Miller, or equipment that has been improperly installed,  
improperly operated or misused based upon industry  
standards, or equipment which has not had reasonable and  
necessary maintenance, or equipment which has been  
used for operation outside of the specifications for the  
equipment.  
1. 5 Years Parts — 3 Years Labor  
*
Original main power rectifiers  
2. 3 Years — Parts and Labor  
*
*
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Process Controllers  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Sources (Unless Otherwise Stated)  
Water Coolant Systems (Integrated)  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by the  
engine manufacturer.)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND  
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS  
TRAINED AND EXPERIENCED IN THE USE AND  
MAINTENANCE OF WELDING EQUIPMENT.  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods at  
customer’s risk and expense. Miller’s option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
3. 1 Year — Parts and Labor Unless Specified  
*
Motor Driven Guns (w/exception of Spoolmate  
Spoolguns)  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources, Coolers, and  
Electronic  
Controls/Recorders  
*
*
*
*
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT,  
INDIRECT,  
SPECIAL,  
INCIDENTAL  
OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY  
OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
Water Coolant Systems (Non-Integrated)  
Flowgauge and Flowmeter Regulators (No Labor)  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND  
Grids  
ANY  
IMPLIED  
WARRANTY,  
GUARANTY  
OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION  
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,  
Spot Welders  
Load Banks  
Arc Stud Power Sources & Arc Stud Guns  
Racks  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Field Options  
INCLUDING  
ANY  
IMPLIED  
WARRANTY  
OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT  
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED  
BY MILLER.  
*
(NOTE: Field options are covered under True Blue®  
for the remaining warranty period of the product they  
are installed in, or for a minimum of one year —  
whichever is greater.)  
Bernard-Branded Mig Guns (No Labor)  
Weldcraft-Branded TIG Torches (No Labor)  
Subarc Wire Drive Assemblies  
Some states in the U.S.A. do not allow limitations of how long an  
implied warranty lasts, or the exclusion of incidental, indirect,  
special or consequential damages, so the above limitation or  
exclusion may not apply to you. This warranty provides specific  
legal rights, and other rights may be available, but may vary from  
state to state.  
*
*
*
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations and  
exclusions set out above may not apply. This Limited Warranty  
provides specific legal rights, and other rights may be available,  
4. 6 Months — Batteries  
5. 90 Days — Parts  
*
MIG Guns/TIG Torches and Subarc (SAW) Guns  
but may vary from province to province.  
miller_warr 200701  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
Contact a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters −  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
To locate a Distributor or Service Agency visit  
www.MillerWelds.com  
Contact the Delivering Carrier to:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims, contact  
your distributor and/or equipment manufacturer’s  
Transportation Department.  
PRINTED IN USA  
© 2007 Miller Electric Mfg. Co.200701  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Mr Heater Gas Heater MH125KTR User Manual
MTD Lawn Mower ZYJ 192A User Manual
Multiquip Portable Generator 36kW through 97kW models User Manual
Nokia Conference Phone HF 510 User Manual
NordicTrack Home Gym NEL70950 User Manual
Novatel Wireless Network Card GU 90023775 User Manual
NuTone Dollhouse 667RN User Manual
Onkyo Home Theater System Y1105 1 User Manual
Panasonic Credit Card Machine AJ DE97P User Manual
Parrot Cell Phone 3200 LS COLOR PLUS User Manual