Installation Instructions
T 9822 Gas Dryer
The T 9822 gas dryer is only
approved for use in the USA
and Canada. It is not approved
for use in Mexico.
en - US, CA
To prevent accidents
and machine damage
read these instructions
before
installation or use.
M.-Nr. 07 431 110
Download from Www.Somanuals.com. All Manuals Search And Download.
,WARNING
For your safety the information in this manual
must be followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
ß Do not try to light any appliance.
ß Do not touch any electrical switch.
ß Do not use any phone in your building.
ß Clear the room, building or area
of all occupants.
ß Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
ß If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
(In Massachusetts a licensed plumber / gas fitter.)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Transporting the dryer to the installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Level the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Determining the position of the exhaust connection . . . . . . . . . . . . . . . . . . . . . . . 12
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
How to calculate the effective duct length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Exhaust connection with a flexible exhaust hose or rigid pipe . . . . . . . . . . . . . . . 23
Direct wall connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation and connection
GROUNDING INSTRUCTIONS
~
This appliance must be grounded. In
the event of malfunction or breakdown,
grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current. This
appliance is equipped with a cord
having an equipment grounding
conductor and a grounding plug. Only
place the plug in an appropriate outlet
that is properly installed and grounded
in accordance with all local codes and
ordinances.
, WARNING - Risk of Fire
When using your gas appliance
follow basic safety precautions
including the following:
It is essential to read all instructions
~
before installing the appliance.
To reduce the risk of severe injury or
~
death, follow all installation instructions.
Clothes dryer installation must be
~
performed by a qualified installer.
WARNING – Improper connection of
~
the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician if you
are in doubt as to whether the
Install the clothes dryer according to
~
the manufacturer's instructions and
local codes.
appliance is properly grounded.
Repair and maintenance work
~
Do not modify the plug provided
should be performed by a qualified
installer, service agency or the gas
supplier. Work by unqualified persons
could be dangerous and could void the
warranty.
~
with the appliance! If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.
Do not use an extension cord to
~
connect this appliance to the power
supply. Extension cords do not
In Massachusetts:
~
This dryer must be installed by a
licensed plumber or gas fitter.
guarantee the required safety of the
appliance (e.g. danger of overheating).
Before installation, disconnect the
~
This dryer must be vented outdoors
tumble dryer from the electrical supply
by shutting off the power main,
~
to reduce the risk of fire. Be sure to
observe local building codes.
unplugging the power cord or tripping
the circuit breaker. Do not restore
power until the installation is complete.
Use flexible or rigid metal pipe for
~
venting. Non-metallic flexible hose
should not be used, it is a potential fire
hazard.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Do not install a clothes dryer with
~
flexible plastic venting materials. If
flexible metal (foil type) duct is
installed, it must be of a specific type
identified by the manufacturer as
suitable for use with clothes dryers.
Flexible venting materials are known to
collapse, be easily crushed, and trap
lint. These conditions will obstruct
clothes dryer airflow and increase the
risk of fire.
The appliance shall not be
~
exhausted into a chimney, a wall, a
ceiling, an attic, a crawl space, or a
concealed space of a building.
Do not install the machine in rooms
~
where temperatures below freezing
may occur.
Proper installation is the
~
responsibility of the installer.
Product failure due to improper
~
installation is not covered under the
Warranty.
Gas dryers are not approved for
~
mobile home installation.
If there is any doubt concerning
~
installation, contact Miele’s Technical
Service Department.
U
V
1-800-999-1360
1-800-565-6435
SAVE THESE
INSTRUCTIONS
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Front view
a Exhaust connection
b Power cord with plug
c Control panel
Stand
A dryer stand, with drawer, can be
purchased as an optional accessory.
d Door
e Four height adjustable screw feet
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Rear
a Handle for transportation (arrows)
b Power cord with plug
c Slot for module
,WARNING : Do not remove the
restriction insert in the vent
opening. It may result in poor drying
results, damage to the laundry and
higher Carbon monoxide emissions.
Exception: The restriction insert
must be removed if the exhaust
connection if moved to the left or
right side of the dryer.
d Air intake
e Gas connection
f Exhaust connection with restriction
insert
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation site
,WARNING:
, The National Fuel Gas Code
restricts installations of gas
appliances in garages. They must
be 18 inches off the ground and
protected by a barrier from
vehicles.
Do not install the dryer:
- outdoors
- in an environment with dripping
water or weather
- near flammable materials
- in rooms which may contain gas
or other fuels
- in closets with solid doors
- with other fuel-burning
appliances in the same closet
- in a location where its door
could conflict with room doors.
- next to a refrigerator
- under a countertop
- on top of a washer.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation site
Confined space installation
Minimum installation clearance
^ When installed in any space with less
than 122 square feet, minimum
clearances around the dryer must be
adhered to for proper ventilation and
vents for make up air must be
installed.
^ Do not install any other fuel-burning
appliance in the same space as the
dryer.
Confined door openings
Any doors limiting circulation must be
louvered or otherwise ventilated.
A minimum of 200 square inches
(1,290 cm2) of opening is required. It
must be equally divided within 12"
(30.5 cm) from the top and bottom of
the door.
Sides: 0 " (0 cm)
Top: 12" (30.5 cm)
Rear: 0" (0 cm) (as close to wall as
gas connection and venting allows)
Front to door: 2" (5 cm)
Make sure the dryer door can open
completely once installed.
Exhaust duct clearance
to combustible material: 2" (5 cm)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Transporting the dryer to the
installation site
Level the dryer
The rear of the lid has a handle for
transportation.
^ Use the front dryer feet and the rear
of the lid to move the dryer to the
installation site.
The dryer must be level to ensure safe
and proper operation.
^ Unscrew the four feet as necessary
by turning the foot, 1, and the locking
nut, 2, to the left.
^ Once level, hold the foot, 1, still with
adjustable pliers. At the same time,
turn the locking nut, 2, to the right
using a wrench.
,The dryer lid cannot be
removed.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
,WARNING
,WARNING
With left or right exhaust
connections, the restriction insert
must be integrated into the side
exhaust ducting guide.
Before installation, disconnect the
tumble dryer from the electrical
supply by shutting off the power
main or tripping the circuit breaker.
Be sure the dryer power cord is
unplugged from the wall.
Otherwise poor drying results,
damage to the laundry and higher
Carbon monoxide emissions may
occur.
Do not restore power until the
installation is complete.
^ Place the restriction insert into the
adapter (see "Exhaust connection
with a flexible exhaust hose or rigid
pipe").
Turn the dryer’s gas shutoff valve in
the supply line to the OFF position.
Disconnect and discard old flexible
gas connector and ducting material.
Determining the position of the
exhaust connection
The exhaust connection can be left at
the rear of the dryer (factory standard)
or moved to the left or right side.
Changing the position of the exhaust
connection
^ Remove the exhaust connection
cover on the left or right side of the
dryer by turning it counterclockwise
and take it out.
^ Firmly press the cover into the rear
exhaust connection.
^ Remove the restriction insert.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical connection
The dryer is supplied with a 5’ 7"
(1.7 m) 3x14 AWG cord and a
NEMA 5-15 P plug, ready for
connection to a 120 V, 60 Hz, 15 A AC
power supply.
,GROUNDING INSTRUCTIONS
This appliance must be grounded.
In the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by
^ Plug the machine into a proper outlet.
providing a path of least resistance.
This appliance is equipped with a
cord having an equipment
If the plug does not fit, have a proper
outlet installed by a qualified
electrician.
grounding conductor and a
grounding plug. The dryer, when
installed, must be electrically
grounded in accordance with local
codes, or in the absence of local
codes, with the National Electrical
Codes ANSI/NFPA 70, or the
Canadian Electrical Code, CSA
C22.1.
WARNING – Improper connection of
the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician,
service representative or personnel
if you are in doubt as to whether the
appliance is properly grounded.
,WARNING – This dryer is
equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly
grounded three-prong receptacle.
Do not cut or remove the grounding
terminal from this plug.
Do not modify the plug! If it will not
fit the outlet, have a proper outlet
installed by a qualified electrician.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas connection
Gas type
,WARNING
The gas dryer is equipped for
connection to a NATURAL GAS
supply.
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
The maximum heat output is
19,500 BTU/H (5,7 kW).
In Massachusetts a licensed
plumber / gas fitter is required.
Minimum gas supply pressure
to obtain the required gas input is:
0.15 psi (4" WC) for natural gas
0.29 psi (8" WC) for LP gas.
This appliance must be installed
with its own shut off valve in the
same room. The valve must be
easily accessible to the consumer to
turn on or shut off the gas supply
after the appliance is installed.
Maximum gas supply pressure
before the gas pressure regulator
0.37 psi (10" WC) for natural gas
0.46 psi (13" WC) for LP gas.
During any pressure testing of the
gas system this appliance must be
disconnected from the gas supply
by closing its individual manual shut
off valve.
Any pipe connections must be made
using a thread sealant approved for
gas connections. Failure to correctly
install these items could lead to a
gas leak and subsequent explosion.
The gas installation must be made in
accordance with local codes or, in
the absence of local codes, with
-
National Fuel Gas Code,
ANSI Z223.1/NFPA 54 for USA
or
-
Natural Gas and Propane
Installation Code,
CSA B149.1 for Canada.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas connection
Gas supply
Installation material (hoses and
adapters) must be provided by the
installer.
Gas connection distances
aFlare union adapter
b1/8" NPT pressure tapping plug
cGas shut-off valve
For convenience (if allowed by code),
an AGA or CGA approved flexible
stainless steel gas hose (accordion
type) may be used between the gas
shut-off valve and the dryer. This will
allow the appliance to be moved from
the installation site for cleaning or
servicing. Make sure that nothing rubs
on the gas hose.
This appliance must be installed with its
own shut off valve on the gas supply
line. The valve must be within 6 ft.
(1.8 m), and in the same room, of the
dryer.
An 1/8" NPT pressure tapping plug
must be installed immediately upstream
of the gas supply connection. This
allows the gas inlet pressure to be
checked.
If there is any doubt concerning
installation, contact the Miele Technical
Service Department at the phone
number listed on the back of this
manual.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas connection
,To secure all connections use
appropriate Teflon tape or a thread
compound, suitable for gas
connections.
^ Install a 3/8" flare union adapter, a, to
the female elbow, b.
Hold the elbow with a wrench.
^ At the end of the dryer's gas
connection hand screw on the
3/8" NPT elbow.
Using a wrench tighten the elbow
with a half turn.
,DO NOT OVERTIGHTEN.
^ Secure the flexible metal gas line
connector to the adapter.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas connection
^ Using two wrenches tighten all
connections.
^ Using two wrenches tighten the
flexible gas line connection.
,DO NOT OVERTIGHTEN.
^ Connect the flare union adapter, a,
to the pressure tapping plug, b,
originally installed on the gas shut off
valve, c.
^ Open the gas shut-off valve.
^ After connecting the appliance
check all fittings for gas leaks e.g.
with soapy water or an equivalent.
,WARNING
NEVER USE AN OPEN FLAME TO
TEST FOR GAS LEAKS.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Exhaust ducting and
connections
,WARNING
A gap of 3/8" (10 mm) must be
provided between the machine and
the floor. This gap is necessary for
proper air flow and must not be
blocked by a toe-kick or thick piled
carpets.
Danger of toxic fumes.
The exhaust gases from the dryer
must only be vented outside the
building.
DO NOT terminate the exhaust
ducts in a chimney, fireplace
ducting, a combustion appliance
vent flue, or enclosed,
Sufficient venting of the installation
site is essential for proper dryer
operation. Inadequate ventilation will
increase energy use and drying
times.
unventilated area such as attics,
garages, crawlspaces, walls,
ceilings or concealed space of a
building.
To reduce the risk of fire, only use
metal ductwork.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
How to calculate the effective
duct length
Note:
Maximum effective duct lengths:
4" (100 mm) diameter
5" (125 mm) diameter
6" (150 mm) diameter
66 ft (20 m)
131 ft (40 m)
328 ft (100 m)
The overall duct length will determine
the duct diameter (see the "Additional
duct lengths" table). In Canada the
exhaust duct must be 4" (102 mm) in
diameter.
If using flexible metal duct the total
length must not exceed 7' 10" (2.4 m).
^ Measure the actual duct length
needed to go from the dryer’s
See the "Additional duct lengths"
table for more information on
maximum duct lengths and number
of bends.
exhaust connection to the vent outlet:
1. Establish the number of elbows or
bends necessary, noting the type of
bend, angle and radius involved
(see the "Additional duct lengths"
table).
Effective duct lengths over 66 ft (20 m)
require a larger duct diameter.
Longer ducts may lead to decreases in
dryer efficiency if the next larger duct
diameter is not followed.
2. Add the additional duct length (as
derived by using the values
specified in the "Additional duct
lengths" table) to the actual duct
length to get the effective length.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Tips about the ductwork
– Do not assemble the duct with
screws or other fastening devices
that extend into the duct and catch
lint.
– Check with your local building code
to determine the maximum allowable
duct length.
– The shorter the exhaust ductwork,
the more efficient the dryer will be.
Expelled air is slowed down in the
ducts due to friction against the inner
walls. The shorter and smoother the
inner walls are, the less friction will
be created.
– Only use rigid or flexible metal duct
for exhausting. Non-metallic flexible
hose should not be used, it is a
potential fire hazard.
– Rigid metal or flexible aluminum
ducting is preferred. Flexible foil
ducting may move and bounce due
to the high airflow of the dryer. This
could lead to a thumping or grinding
noise.
– An elbow or bend creates more
friction than a straight duct. An
additional duct length factor must be
added for each elbow or bend (see
Table). This factor expresses the
resistance of the bend in terms of a
straight length of duct.
– Non-metallic flexible hose should not
be used. It is a potential fire hazard.
– In the United Stated foil-type flexible
ducts should only be used if
identified for use by the manufacturer
as compliant with the Outline for
Clothes Dryer Transition Duct,
Subject ANSI/UL 2158A.
The additional length factor is then
added to the existing duct to give the
effective duct length.
A larger duct diameter helps to
reduce friction. Therefore duct
diameter should be increased if
longer duct lengths are required.
In Canada, only flexible metal
(foil-type) ducts specifically identified
for use by the manufacturer should
be used.
– For best drying results avoid extra
long ducting with too many bends,
angles or tight corners.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Additional duct lengths (4" (100 mm) rigid pipe only)
Type of bend
Radius
inches
Additional duct length
cm
ft
cm
Flexible metal duct
– 3’ 3" (1 m) straight
– 45° angle
5’ 11"
4’ 11"
8’ 2"
180
150
250
10"
10"
25
25
– 90° angle
Smooth metal duct
– 3’ 3" (1 m) straight
– 45° angle
3’ 3"
1’ 11"
2’ 7"
100
60
10"
10"
25
25
– 90° angle
80
Elbow 90° sharp
7’ 6"
2’ 4"
230
Concertina bend
– 90° angle
8"
20
70
Wall vent or window vent
– with louvers
12’ 5"
4’ 11"
19’ 8"
380
150
600
– with flap
– with weather hood
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Example
Rigid pipe
A
Duct length
ft
Duct length
m
12’ 5"
3.8 m
Wall duct with louvered
wall vent
B
C
D
E
2’ 4"
1’ 7"
2’ 4"
3' 3"
18’ 8"
0.7 m
0.5 m
0.7 m
1.0 m
5.7 m
90° bend
20" (0.5 m) rigid pipe
90° bend
left / right vent opening
Total duct
length
The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm)
with adapter is sufficient.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Exhaust connection with a
flexible exhaust hose or rigid
pipe
,WARNING
Do not remove the restriction insert
in the vent opening. It may result in
poor drying results, damage to the
laundry and higher Carbon
Using the adapter supplied, an
exhaust hose (4" [100 mm]
diameter) can be installed.
monoxide emissions.
Necessary materials:
The exhaust duct must not be
– a wall or window duct
(available from Miele)
connected or secured with screws
or other fastening devices which
extend into the interior of the duct.
– an exhaust hose made of approved
non-flammable material
Exhaust connection on left or right
^ Install the required adapter* 1 with
the exhaust hose or pipe 2 to the
dryer.
^ Place the restriction insert 1 into the
adapter 2.
* The white adapter with clips is
used for connection to a hose; the
gray adapter without clips is used
for connection to a pipe.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Window connection (example)
^ Install the exhaust hose 3 in the dryer
using the adapter 2 and the
restriction insert 3.
1 Window duct
2 Connector for the rigid or flexible
exhaust hose
If using the gray adapter without clips :
Wall connection (example)
^ Plug the restriction insert 1 into the
gray adapter without clips 2 and
connect the pipe 3.
1 Wall pipe (Installation sheet supplied
with the Miele wall pipe)
2 Connector
3 Rigid pipe
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Ducting
Direct wall connection
Necessary materials:
– a wall pipe
Dryer side view
– flexible foam gasket
Dryer top view
1 Wall pipe
2 Flexible foam gasket
1 Wall pipe
2 Flexible foam gasket
^ Only required with side exhaust vent
connection (left or right) : Plug the
restriction insert 1 into the wall pipe.
^ Connect the flexible foam gasket 3 to
the wall pipe connector 2.
^ Push the dryer to the wall.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of the packing
materials
Disposal of an appliance
Old appliances may contain materials
that can be recycled. Please contact
your local recycling authority about the
possibility of recycling these materials.
The packing materials protect the
appliance during shipping. They have
been designed to be biodegradable
and recyclable.
Ensure that a discarded dryer presents
no danger to children. When being
stored for disposal remove the door to
the drying compartment.
To prevent suffocation, ensure that any
plastic wrappings, bags, etc. are
disposed of safely and kept out of the
reach of children.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
All rights reserved / 0209
M.-Nr. 07 431 110 / 01
For the most updated manual see the Miele web site.