Operating and Installation
Instructions
Ventilation System
DA 3460
DA 3480
DA 3490
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 09 190 990
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
READ AND SAVE THESE
INSTRUCTIONS
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
Keep these instructions in a safe
place and pass them on to any future
user.
OBSERVE THE FOLLOWING:
a) Use this appliance only in the
~
manner intended by the manufacturer.
If you have questions, contact Miele.
Read these instructions carefully
before installing or using the
Ventilation System.
b) Before servicing or cleaning the
~
appliance, switch power off at the
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally. If
the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
This appliance is intended for
residential use only. Use the appliance
only for its intended purpose.
~
This appliance complies with current
~
safety requirements. Improper use of
the appliance can lead to personal
injury and material damage.
c) Be certain your appliance is
properly installed and grounded by a
qualified technician.
~
,CAUTION
For General Ventilating Use
Only. Do Not Use To Exhaust
Hazardous Or Explosive
Materials And Vapors.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician.
This appliance is designed to vent
~
cooking smoke and odors only.
This appliance is suitable for
~
installation above gas or electric
cooking surfaces.
This appliance is not intended for
outdoor use.
~
This appliance must not be used in
~
a non-stationary location (e.g. on a
ship).
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
d) Before connecting the appliance
Use
~
to the power supply make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply.
This data must correspond to prevent
appliance damage. If in doubt consult a
qualified electrician.
,WARNING
TO REDUCE THE RISK OF A
COOKTOP GREASE FIRE:
a) Never leave surface units
~
unattended at high settings. Boilovers
cause smoking and greasy spillovers
may ignite. Heat oils slowly on low or
medium settings.
e) Installation work and repairs
~
should only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous.
b) Always turn the hood on when
~
cooking at a high heat.
c) Clean the ventilation hood
~
f) Only open the housing as
frequently. Grease should not be
allowed to accumulate on the fan or
filter.
~
described in the enclosed "Installation
diagram" and in the "Cleaning and care"
section of this manual. Under no
circumstances should any other parts
of the housing be opened. Tampering
with electrical connections or
d) Use the proper pan size. Always
~
use cookware appropriate for the size
of the cooking area.
components and mechanical parts is
highly dangerous to the user and can
cause operation faults.
e) Do not flambé or grill with an
~
open flame beneath the hood.
Flames could be drawn up into the
hood by the suction and the grease
filters may catch fire.
g) Before discarding an old
~
appliance, disconnect it from the power
supply and remove the power cord to
prevent hazards.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
Do not allow children to play with or
operate the appliance or its controls.
Supervise its use by the elderly or
infirm.
~
TO REDUCE THE RISK OF
INJURY TO PERSONS IN THE
EVENT OF A COOKTOP
GREASE FIRE, OBSERVE THE
FOLLOWING*:
Always turn on the hood when using
~
the cooktop to prevent damage from
condensation.
a) SMOTHER FLAMES with a close
fitting lid, cookie sheet, or metal tray
then turn off the burner.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
~
Never operate gas burners without
~
cookware. Turn the burner off when not
in use. Adjust the burner so that the
flames do not extend beneath the
cookware. Do not overheat the
cookware, e.g. when using a wok. The
hood can be damaged due to
excessive heat from the burners and
the cookware.
b) NEVER PICK UP A FLAMING
~
PAN - You may be burned.
c) DO NOT USE WATER, including
wet dishcloths or towels - a violent
steam explosion will result.
Do not use the hood without the
grease filters in place.
~
~
Do not use a steam cleaner to clean
~
d) Use a fire extinguisher ONLY if:
the hood. Steam could penetrate
electrical components and cause a
short circuit.
~
1) You have a class ABC
extinguisher, and you know how to
operate it.
2) The fire is small and contained in
the area where it started.
3) The fire department is being
called.
4)You can fight the fire with your
back to an exit.
*
Based on "Kitchen Firesafety Tips"
published by NAFTA
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation
g) Do not install this hood over
~
cooktops that burn solid fuel.
,WARNING
h) Provided a larger distance is not
~
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
given by the manufacturer of the
cooktop, follow the minimum safety
distances between a cooktop and the
bottom of the hood given in the
"Appliance dimensions" section of this
manual.
a) Installation work and electrical
~
wiring must be done by qualified
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction.
If local building codes require a greater
safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
b) Sufficient air is needed for
~
combustion and exhausting of gases
through the flue (chimney of fuel
burning equipment to prevent back
drafting. Follow the heating equipment
manufacturer’s guideline and safety
standards such as those published by
the National Fire Protection Association
(NFPA) and the American Society for
Heating, Refrigeration and Air
i) Never connect an exhaust hood to
~
an active chimney, dryer vent, vent flue,
or room ventilating ductwork.
j) Seek professional advice before
~
connecting an exhaust hood vent to an
existing, inactive chimney or vent flue.
Conditioning Engineers (ASHRAE), and
the local code authorities.
k) Any fittings, sealant, or materials
~
used to install the ductwork must be
made of approved non-flammable
materials.
c) When cutting or drilling into the
wall or ceiling, do not damage electrical
wiring and other hidden utilities.
~
d) Ducted hoods must always be
vented to the outdoors.
~
,WARNING
TO REDUCE THE RISK OF
FIRE USE ONLY METAL
DUCTWORK.
e) Do not use this hood with any
~
solid-state speed control device.
f) Do not use an extension cord to
~
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance,
(e.g. danger of overheating).
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional description
The ventilation hood offers two modes
of operation:
Air extraction
Recirculation mode
Air is drawn through the grease filters
and an active charcoal filter. The
filtered air is then recirculated back into
the kitchen.
The air is drawn in and cleaned by the
grease filters and directed outside.
The hood comes equipped with a
non-return flap. The flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the
exhaust fan automatically opens the
flap blowing the inside air and cooking
odors outside.
The recirculation mode requires an
install kit and charcoal filter which are
optional accessories.
Before using the hood in
recirculation mode, ensure that the
active charcoal filter is in place, see
"Cleaning and care".
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the Ventilation System
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the Ventilation System
a Vent connection
b Control panel
c Grease filter
h On/Off button
i Power level buttons
Four fan speed selection
j Light button
d Expandable fume deflector
e Overhead cooktop light
f Active charcoal filter
Optional accessory for recirculation
mode
g Facia Panel
Accepts a custom front panel with the
DML 400 kit, optional accessory
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
The ventilation system is operated by
pulling out and pushing in the
expandable fume deflector.
To turn the fan off
^ Push the fume deflector back in. The
next time the fume deflector is pulled
out, the ventilation system will
To turn the fan on
operate at power level 2 again.
^ Pull the fume deflector out.
or
The fan turns on to Level 2 .
The K symbol and the 2 of the power
level indicator light up.
^ Press the On/Off button K for the fan.
All the indicator lights go out.
To turn the lighting on
^ Pull the fume deflector out,
or
Selecting the power level
^ Press the "–" symbol to select a lower
power level or the "+" symbol for a
higher power level.
^ Press the I button for the overhead
lighting.
Depending on the amount of cooking
odors, levels 1 to 3 are usually sufficient
for normal cooking.
When the lighting is turned on, the
indicator light of the I button lights up.
Intensive setting
To turn the lighting off
^ For short periods of cooking food
with intensive vapors and a strong
aroma, e.g. when searing meat, you
may wish to select the Intensive
Setting IS.
Pull the fume deflector all the way out
to achieve optimum extraction and to
prevent unnecessary noise levels.
^ Push the fume deflector back in,
or
^ Press the I button for the overhead
lighting.
The indicator light goes out.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Automatically switching back the Automatic Safety Shut-Off
intensive power level
If the ventilation system is left on, the
The intensive level can be programmed fan will turn automatically off 10 hours
to automatically switch back to level 3
after 10 minutes.
after the last button was activated. The
lighting however will remain on.
^ To set this option, the fan and the
overhead lighting must be turned off
and the fume deflector pushed in.
^ Press the On/Off button K to turn the
fan back on again.
^ Press and hold the "–" and "+" buttons
for approx. 10 seconds until power
level indicator 1 lights up.
^ Then press the following buttons one
after another :
– overhead lighting I,
– the "–" button, and
– overhead lighting I again,
If the indicators 1 and IS flash, the
automatic switch back is not activated.
^ To activate the automatic switch
back, press the "+" button.
The power level indicators 1 and IS
light continuously.
To deactivate, press the "–" button.
^ Press the On/Off button K to confirm.
^ If the procedure is not stored within 4
minutes, the hood will automatically
default to the "old" data.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and care
,WARNING
Avoid:
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
– cleaning agents containing soda,
acids or chlorides,
– abrasive cleaning agents
e.g. powder or cream cleansers,
– abrasive sponges, e.g. pot scourers
or sponges which have been
previously used with abrasive
cleaning agents.
Before cleaning or servicing the
hood, disconnect it from the power
supply, see "Important Safety
Instructions".
These will damage the surface.
The following instructions for cleaning
"Stainless steel" surfaces and "Stainless
steel colored controls" should be
followed in addition to the general
"Cleaning the casing" instructions.
,The halogen bulbs are very hot
when in use. They stay hot for some
time after turned off. Use caution,
danger of burns.
Wet cleaning the hot bulbs will
cause damage.
Stainless steel surfaces
Wait a few minutes after turning
them off before cleaning.
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
Cleaning the casing
To help prevent resoiling, a conditioner
for stainless steel can be applied.
Never use abrasive cleaners,
scouring pads, steel wool or caustic
(oven) cleaners on the hood. They
will damage the surface.
Stainless steel colored controls
These controls may become dis-
colored or damaged if not cleaned
regularly.
Do not use a stainless steel cleaner
on these controls.
^ All external surfaces and controls can
be cleaned with a mild solution of
warm water and liquid dish soap
applied with a soft sponge.
^ Wipe dry using a soft cloth.
Do not use too much water when
cleaning the controls. Water could
penetrate the electronics and cause
damage.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and care
Grease filter
Cleaning the filter
The reusable metal grease filter
removes solid particles from the vented
kitchen air (grease, dust, etc).
^ By hand: use a scrub brush with a
solution of warm water and mild
detergent.
Do not use the pure detergent,
aggressive all purpose cleaners,
oven sprays, abrasive cleaning
agents or limescale removers. They
could destroy the filter.
The grease filter should be cleaned
every 3 - 4 weeks.
,A dirty filter is a fire hazard.
^ In a dishwasher: place the filter
vertically in the lower basket, making
sure that the spray arm is not
blocked.
Use a wash program with a max.
temperature of 150°F (65°C). In a
Miele dishwasher use the "Normal"
program.
Use the recommended amount of
dishwasher detergent. Overuse could
destroy the filter.
^ To remove hold and pull out the
deflector and the grease filter
together.
Depending on the detergent,
cleaning the grease filter in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
^ Pull the grease filter downwards and
out. Support the grease filter so that it
does not fall onto the cooktop.
^ Turn the hood off.
^ After cleaning, the filter can be
placed on a towel to air dry.
^ While the filter is removed, clean any
dirt or grease from the filter casing to
prevent the risk of fire.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and care
Inserting / replacing the active
charcoal filters
For recirculation mode an active
charcoal filter must be used in addition
to the grease filter. The charcoal filter is
designed to absorb cooking odors. The
active charcoal filter is inserted above
the grease filter.
^ To insert the grease filter, make sure
that the red plastic guides are at the
front and facing up.
^ Insert the grease filter in the deflector
and push upwards. It should glide
onto the fixing pins.
^ Replace the filter every 6 months or
when it is no longer absorbing
cooking odors.
Replacement active charcoal filters
can be ordered from Miele.
^ Follow the instructions supplied with
the active charcoal filter.
^ Dispose of the charcoal filter with the
household waste.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and care
Changing the light bulbs
,WARNING
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Before changing the light bulbs,
disconnect the hood from the power
supply, see "Important Safety
Instructions".
When in use halogen bulbs become
extremely hot, use caution. Do not
attempt to change the bulbs until
they have had sufficient time to cool.
^ Reach through the grille opening and
push the light fixture downwards.
Do not touch the bulb surface.
Fingerprints or body oils deposited
on the bulb will decrease its life.
Follow the bulb manufacturer’s
instructions.
^ Turn the bulb counterclockwise and
pull it out of its socket.
^ Replace the bulb with a new one
(GU/GZ 10, 120V, 50W) in the
reverse order and push upwards.
^ Pull the deflector out and remove the
grease filter as described in
"Cleaning and Care - Grease filter".
^ Return the grease filter and if existent
the active charcoal filter.
^ Remove the active charcoal filter if
existent.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
After Sales Service
Repairs
MieleCare
In the event of a fault which you cannot
easily fix yourself, please contact the
Miele Technical Service Department.
(USA only)
MieleCare, our Extended Service
Contract program, gives you the
assurance of knowing that your
^ When contacting the Technical
Service Department, please quote
the model and serial number of your
appliance.
appliance investment is covered by
5 years of worry free ownership.
MieleCare is the only Extended Service
Contract in the industry that guarantees
repairs by a Miele Authorized Service
Provider using genuine Miele parts.
Only genuine Miele parts installed by
factory trained professionals can
guarantee the safety, reliability, and
longevity of your Miele appliance.
These are shown on the data plate
which is visible when the grease filters
are removed.
Please note that unless expressly
approved in writing by Miele’s Service
department, Extended Service
Contracts offered by other providers for
Miele products will not be recognized
by Miele. Our goal is to prevent
unauthorized (and untrained) service
personnel from working on your Miele
products, possibly doing further
damage to them, you and/or your
home.
To learn more about MieleCare
Extended Service Contracts, please
contact your appliance dealer or visit
us online at:
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Read these instructions and the "Important Safety Instructions" before installing
this ventilation system.
The installation steps are described in the enclosed "Installation Diagram".
Leave these instructions with the appliance for the consumer/user.
Information is subject to change. Please refer to our website to obtain the most
current product specification, technical & warranty information.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling center about the
possibility of recycling these materials.
Before discarding an old appliance,
disconnect it from the electrical
supply and cut off the power cord to
prevent it from becoming a hazard.
,DANGER
Ensure that any plastic wrappings,
bags, etc., are disposed of safely
and kept out of the reach of babies
and young children. Danger of
suffocation!
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
* The hood can also be installed in a 23 5/8" (60 cm) cabinet.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
* The hood can also be installed in a 23 5/8" (60 cm) cabinet.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
1) Air extraction mode; consider accessories when measuring cabinet height and
cut-outs (e.g. muffler).
2) Recirculation mode with Installation kit DUU 151
Distance between cooktop and hood (S)
Do not install this exhaust hood over cooktops burning solid fuel.
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood:
Miele Cooktops
Non-Miele
Cooktops
Electric Cooktops
24" (610 mm)
26" (660 mm)
Electric Barbeques and Fryers
Multiburner Gas cooktops
< 43,000 BTU (12.6 KW)
and no burner > 15,000 BTU (4.5 KW)
26" (660 mm)
30" (760 mm)
Single burner (Wok) < 20,500 BTU (6 KW)
All other gas cooktops
26" (660 mm)
30" (760 mm)
30" (760 mm)
– If several gas surfaces are installed under the hood, the total output must be
considered when determining the minimum safety distance.
– If installing the exhaust hood in an overhead cabinet or if using a front panel
made of wood or plastic, observe the instructions of the manufacturer of the
gas cooktop regarding the use of flammable materials above the cooktop. If not
otherwise specified in the instructions, ensure a distance of at least 30”
(760 mm) from the gas cooktop.
– If local building codes require a greater safety distance, follow their requirement.
– If there is more than one appliance beneath the hood and they have different
minimum safety distances always select the greater distance.
See "Important Safety Instructions" for further information.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation accessories
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
a 2 runners
(1 x right, 1x left) to support the hood
in the cabinet.
8 screws 4 x 15 mm
to anchor the ventilation hood in the
cabinet.
b 1 spacer strip
to conceal the gap between the rear
of the appliance and the wall.
c Installation kit for recirculation
mode; contains air outlet grille, hose
and hose clips
8 screws M4 x 12 mm
to anchor the ventilation hood at the
runners.
(optional accessory)
d Installation kit DML 400 to install a
custom panel
4 screws could be used (alternatively to
the plastic rivet) to fix the spacer bar.
contains retractable brackets and
screws (optional accessory)
2 screws 4 x 15 mm
to anchor the ventilation hood at rear
wall.
,CAUTION
To avoid risk of hand or other injury,
avoid contact with sharp edges
during the assembly and installation
process.
4 plastic rivets
to connect the space bar with the
appliance rear wall.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
1. Installing the space bar
T = K cabinet depth minus G hood
depth
^ The hood depth G depends on the
custom panel:
– a Hood installed without front panel
– b Hood installed with a cabinet
matching custom panel
^ Screw the space bar flush with the
wall under the cabinet side walls.
These measures are only valid for the
installation if the front panel sits flush
with the cabinet corpus (without the
door).
If the front panel should be installed
recessed or flush with the cabinet door,
adjust the measure T accordingly.
^ Cut the supplied space bar to
measure T.
^ At the front edge of the spacer strip
draw a vertical line on left and right
side of the inside cabinet.
Clip it with a knife at the predeter-
mined breaking point of the next
lower measure.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
2. Runners
3. Installing the hood in the
cabinet
^ Lay the hood on its back side.
Do not remove the installation
protector between the deflector and
casing before the installation is
completed.
The runners are made for side walls of
5/8" (16 mm) and 3/4" (19 mm). Screw
on the angled side which has the
imprint of the respective cabinet wall
measure.
^ Align the runners with the drawn line
and be sure that they are flush with
the lower edge of the cabinet side
wall. Screw the runners on the left
and right side in the cabinet.
^ Hold the grease filter and pull it out
along with the deflector.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
^ Take the grease filter out and put it
aside.
^ Push the deflector back in.
^ Insert the hood into the cabinet from
below and until the spring clips click
into place.
^ When installing a 29 13/16" (80 cm) or
a 35 1/4" (90 cm) hood into a 23 5/8"
(60 cm) cabinet, unscrew the
deflector spring clips while the
deflector is pulled out.
^ To dismount the appliance: unscrew
the screws to the left and the right of
the inner side of the hood. The
installation springs loosen and the
hood can be removed from the
cabinet.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
4. Secure the appliance
^ Push the hood back so it sits flush
with the front of the spacer strip.
^ Pull the deflector out.
Fig 1
^ Screw the fixing brackets to the
cabinet rear wall.
^ Screw the hood, with 4 screws, onto
the runners.
^ Remove the installation protection
between the deflector and casing.
Fig 2
^ Align the casing and tighten the
screws.
^ Loosen the screws of the fixing
brackets on the hood top.
^ Push the bracket flush to the wall or
the cabinet back wall.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
The DA3460, DA3480 and DA3490
Built-In Ventilation Hoods all include
brackets to affix the hood body to
the rear wall of the enclosing
cabinet. (Fig. 1) These brackets are
necessary to ensure the long-term
rigidity and stability of the installed
appliance. In many cases, we have
found that the rear walls of some
cabinets are not structurally reliable.
This may be due to the materials
used, or the thickness of the rear
wall.
^ Connect the space bar from the rear
with 4 plastic rivets at the hood rear
side.
In this case, to guarantee a solid
connection, these brackets must be
attached to a structurally sound
surface (such as the wall behind the
cabinet) to maintain the hood's level
attitude (Fig 2). Depending on the
cabinet and wall construction,
alternative hardware may be
5. Install the front panel
if necessary
required. Please use hardware
which is designed to be used for
your specific installation application.
Failure to do so may cause the hood
to lean forward and cause
permanent damage to the sliding
shelf. This damage is not covered
by the warranty!
The installation kit DML 400 is
necessary. It can be obtained as an
optional accessory from Miele. The
installation kit has an installation manual
supplied.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Weight of the front panel
6. Install the grease filter
The weight of the front panel must not
exceed 2.8 lbs (1.3 kg). This applies for
front panels with a depth of up to 1 1/4"
(30 mm). In the case of front panels of
greater depth or greater weight, the
weight must be reduced by milling out
the back of the panel, for instance.
^ Remove the protective film from the
grease filter frame.
^ To reinsert the grease filter, pull the
deflector out.
^ The deflector can be adjusted up to
1 3/8" (35 mm) towards the front with
the two adjusting screws left and
right in the deflector. Adjust the
deflector until it is flush with the front
of the adjacent cabinetry.
^ Make sure that the red plastic
guides are at the front and facing up.
^ Insert the grease filter into the
deflector, and push upwards. It
should glide onto the fixing pins.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
7. Venting
Air extraction mode
^ Complete the venting installation, see
"Air extraction".
Recirculation mode
If the hood cannot be installed for air
extraction the appliance must be
connected for recirculation mode.
For recirculation mode a respective
installation kit is recommended which
can be obtained from Miele.
In addition an active charcoal filter is
needed.
^ Install the installation kit as described
in the manual supplied with the kit.
^ The non-return flap is not needed for
the recirculation mode. Pull the
non-return flap off the bracket from
the vent connection.
^ Make sure that the slats in the grill
point towards the center of the room
and not towards a wall or the ceiling.
^ Install the Active Charcoal Filter (see
"Cleaning and care").
8. Electrical connection
Refer to the notes in "Electrical
connection" and "Important Safety
Instructions" before connecting to
the mains.
^ Plug in the power cord.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Exhaust ducting and connections
,WARNING
Use smooth or flexible pipework made
from approved non-flammable
materials for exhaust ducting.
Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
To reduce the risk of fire and to
properly exhaust air, the exhaust
gases extracted by the hood
should be vented outside of the
building only.
To achieve the most efficient air
extraction and quietest noise levels,
consider the following:
– The diameter of the ductwork should
not be less than 6" (150 mm).
– If flat ducting is used, the cross
section must not be smaller than the
cross section of the ventilation
exhaust.
Do not vent exhaust air into
spaces within walls or ceilings or
in attics, crawl spaces or garages.
– The ducting should be as short and
straight as possible.
– Use ductwork with a wide radius.
To reduce the risk of fire, only use
metal ductwork.
– The exhaust duct must not be bent
or compressed.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– Make sure all connections are
secure.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
– If the exhaust is ducted through an
outside wall, a Telescopic Wall Vent
can be used.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Condensate trap
optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical connection
,WARNING
Grounding Instructions
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
This appliance must be grounded. In
the event of an electrical short circuit,
grounding reduces the risk of electric
shock by providing a path of least
resistance. This appliance is equipped
with a cord having a grounding wire
with a grounding plug. The plug must
be plugged into an outlet that is
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA 70)
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
properly installed and grounded.
WARNING - Improper grounding can
result in a risk of electric shock.
If there is any doubt, have the electrical
system of the house checked by a
qualified electrician.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
Do not use an extension cord. If the
power supply cord is too short, have a
qualified electrician install an outlet
near the appliance.
^ Verify that the voltage, load and
circuit rating information found on the
data plate (located behind the
grease filters), match the household
electrical supply before installing the
hood.
Important
The hood comes equipped with a 4 ft
(1.2 m) power cord with a NEMA 5-15
molded plug for connection to a
^ Use only with ventilation hood
cord-connection kits that have been
investigated and found acceptable
for use with this model hood.
120 VAC, 60 Hz, 15 A power outlet.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s
Technical Service Department.
,WARNING:
THIS APPLIANCE MUST BE
GROUNDED
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Maximum load. . . . . . . . . . . . . . . 450 W
Light. . . . . . . . . . . . . . . . . . . . . 2 x 50 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
Weight
DA 3460 . . . . . . . . . . . 27.6 lb (12.5 kg)
DA 3480 . . . . . . . . . . . 29.8 lb (13.5 kg)
DA 3490 . . . . . . . . . . . . . 32 lb (14.5 kg)
37
Download from Www.Somanuals.com. All Manuals Search And Download.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Alteration rights reserved / 3912
M.-Nr. 09 190 990 / 03
INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST
CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
Download from Www.Somanuals.com. All Manuals Search And Download.
|