Miele Cooktop CS 1326 Y User Manual

Product and Cut-out Dimensions  
Page 1 of 4  
CS 1326 Y
T
e
pan Yaki CombiSet  
Location Codes  
1 – Spring clips  
2 – Appliance front  
3 – Installation height  
4 – Power supply box with connection cable, Length = 47 ¼” (1200 mm)  
208 V, 60 Hz, 20 A fuse rating  
240 V, 60 Hz, 15 A fuse rating  
Ensure that the power outlet is accessible after installation  
5 – Rating label – Ensure that the electrical supply matches the rating. Adhere rating label sticker supplied with the  
appliance into the manual.  
Shipping weight 34 lbs (15.4 kg)  
Shipping dimensions 26” (660 mm) L x 19” (483 mm) W x 11” (279 mm) H  
Notes  
Indoor use  
The appliance must not be permanently sealed into the countertop when installed. The sealing strip under the edge of  
the appliance provides a sufficient seal for the countertop.  
All installations must be done in accordance with local codes.  
Drawing is not to scale  
Specification Sheets OJS 02212012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product and Cut-out Dimensions  
Page 3 of 4  
CS 1326 Y
T
e
pan Yaki CombiSet  
The illustration above represents the attachment of spring clips 1 and support bars 2 for 3  
appliances  
An additional support bar is required for each additional appliance. The position for the  
attachment of an additional support bar depends on the width of appliance B.  
Spring Clip installation  
on wood or solid  
Spring Clip installation  
on a granite  
surface countertop  
Place the supplied  
spring clips 1 and the  
support bars 2 at the  
marked positions as  
shown above, by  
countertop  
Position and attach  
the spring clips 1 and  
the support bars 2  
with strong double-  
sided tape 3  
laying them on the  
upper edge of the cut-  
out and then securing  
them with the 1/8” x 1”  
(3.5 x 25 mm) screws  
(supplied)  
Coat the side and  
lower edges of the  
spring clips with  
silicone.  
Fill the space between  
the support bars and  
the countertop with  
silicon  
Location Codes  
1 – Spring Clips  
2 – Support bars (Accessory, item - 27996029D CSZL 1500 (Includes cover 4))  
3 – Space between support bar and countertop  
4 – Cover  
Notes  
All installations must be done in accordance with local codes.  
Drawing is not to scale  
Specification Sheets OJS 02212012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product and Cut-out Dimensions  
CS 1326 Y
T
e
pan Yaki CombiSet  
Safety distances to back wall  
Page 4 of 4  
1 – Wall frame  
2 – Wall covering  
x = thickness of the wall covering  
3 – Countertop  
4 – Countertop cut-out  
5 – Minimum safety distance  
with flammable materials 2" (50 mm)  
with non-flammable materials 2" (50 mm) minus x  
If a wall covering is installed, a minimum safety distance must be maintained between the countertop cut-out  
and the covering, since high temperatures can damage these materials.  
If the covering is made of a combustible material (such as wood), the distance between the countertop cut-out  
and the wall covering must be a minimum of 2" (50 mm).  
For coverings made of non-combustible materials (such as metal, marble, granite or ceramic tiles) the  
minimum safety distance between the countertop cut-out and the wall covering must be 2" (50 mm) minus the  
thickness of the covering.  
For example: thickness of wall covering 9/16" (15 mm) 2" (50 mm) - 9/16" (15 mm) = minimum safety distance  
1 3/8" (35 mm).  
Safety distances to surrounding cabinetry  
Recommended  
Not Recommended  
Not Permitted  
The appliance should only be installed as shown in the above illustrations while maintaining the  
required safety distances shown. Do not install the appliance between two tall cabinets, this is a  
fire hazard.  
A distance of at least 2” (50 mm) must be kept between the countertop and the rear wall  
because of high temperature radiated.  
The minimum distance required from the countertop cut-out to a side wall or tall cabinet right or  
left 2” (50 mm) (Location code 1)  
Safety distance above the appliance  
The minimum safety distance given by the hood manufacturer  
must be maintained between the combiset and the hood above  
it. See the installation instructions for the hood for these safety  
measurements.  
If the hood manufacturers instructions are not available or if  
flammable objects are installed over the combiset (e.g.  
cabinets, utensil rail, etc.), a minimum safety distance of 30”  
(760 mm) must be maintained.  
Notes  
All installations must be done in accordance with local codes.  
Drawing is not to scale  
Specification Sheets OJS 02212012  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Chainsaw QP 301TH User Manual
NETGEAR Network Router XEPS103XEPS103 User Manual
Nikon Camcorder D40x User Manual
Nokia Cell Phone 2128i User Manual
Northern Industrial Tools Impact Driver 150611 User Manual
Oregon Scientific Projector RA368P User Manual
Oster Hair Clippers 76076 User Manual
Panasonic Fax Machine KX PW76CL User Manual
Panasonic Rice Cooker SR TEL18 User Manual
Paradyne Network Card 3161 CSU User Manual