Miele Clothes Dryer T9820 User Manual

Installation instructions for the  
T 9820 Gas Dryer  
The T 9820 gas dryer is only  
approved for use in the USA  
and Canada. It is not approved  
for use in Mexico.  
en - US, CA  
To prevent accidents  
and machine damage  
read these instructions  
before  
installation or use.  
M.-Nr. 07 268 180  
Download from Www.Somanuals.com. All Manuals Search And Download.  
,WARNING  
For your safety the information in this manual  
must be followed to minimize the risk of fire or  
explosion or to prevent property damage,  
personal injury or death.  
Do not store or use gasoline or other flammable  
vapors and liquids in the vicinity of this or any  
other appliance.  
WHAT TO DO IF YOU SMELL GAS  
ß Do not try to light any appliance.  
ß Do not touch any electrical switch.  
ß Do not use any phone in your building.  
ß Clear the room, building or area  
of all occupants.  
ß Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s  
instructions.  
ß If you cannot reach your gas supplier,  
call the fire department.  
Installation and service must be performed by a  
qualified installer, service agency or the gas  
supplier.  
(In Massachusetts a licensed plumber / gas fitter.)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Transporting the dryer to the installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Level the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
How to calculate the effective duct length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Exhaust connection with a flexible exhaust hose or rigid pipe . . . . . . . . . . . . . . . 22  
Direct wall connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Installation and connection  
WARNING – Improper connection of  
~
the equipment grounding conductor  
can result in a risk of electric shock.  
Check with a qualified electrician if you  
are in doubt as to whether the  
When using your gas appliance  
follow basic safety precautions  
including the following:  
appliance is properly grounded.  
Installation, repair and maintenance  
~
Do not modify the plug provided  
~
work should be performed by a  
qualified installer, service agency or the  
gas supplier. Work by unqualified  
persons could be dangerous and could  
void the warranty.  
with the appliance! If it will not fit the  
outlet, have a proper outlet installed by  
a qualified electrician.  
Do not use an extension cord to  
~
connect this appliance to the power  
supply. Extension cords do not  
In Massachusetts:  
~
This dryer must be installed by a  
licensed plumber or gas fitter.  
guarantee the required safety of the  
appliance (e.g. danger of overheating).  
Before installation, disconnect the  
~
This dryer must be vented outdoors  
~
tumble dryer from the electrical supply  
by shutting off the power main,  
to reduce the risk of fire. Be sure to  
observe local building codes.  
unplugging the power cord or tripping  
the circuit breaker. Do not restore  
power until the installation is complete.  
Use flexible or rigid metal pipe for  
~
venting. Non-metallic flexible hose  
should not be used, it is a potential fire  
hazard.  
GROUNDING INSTRUCTIONS  
~
This appliance must be grounded. In  
the event of malfunction or breakdown,  
grounding will reduce the risk of  
electric shock by providing a path of  
least resistance for electric current. This  
appliance is equipped with a cord  
having an equipment grounding  
conductor and a grounding plug. Only  
place the plug in an appropriate outlet  
that is properly installed and grounded  
in accordance with all local codes and  
ordinances.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
The dryer exhaust must not be  
~
connected to a chimney, fireplace  
ducting, a combustion appliance vent  
flue, a wall, ceiling or concealed space  
of a building.  
Do not install the machine in rooms  
~
where temperatures below freezing  
may occur.  
Proper installation is the  
~
responsibility of the installer.  
Product failure due to improper  
~
installation is not covered under the  
Warranty.  
Gas dryers are not approved for  
~
mobile home installation.  
If there is any doubt concerning  
~
installation, contact Miele’s Technical  
Service Department.  
U
V
1-800-999-1360  
1-800-565-6435  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Front view  
a Exhaust connection  
b Power cord with plug  
c Control panel  
Stand  
A dryer stand, with drawer, can be  
purchased as an optional accessory.  
d Door  
e Four height adjustable screw feet  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Rear  
a Handle for transportation (arrows)  
b Power cord with plug  
c Slot for module  
,WARNING  
Do not remove the restriction insert  
in the vent opening. It may result in  
poor drying results, damage to the  
laundry and higher Carbon  
monoxide emissions.  
d Air intake  
e Gas connection  
f Vent connection with restriction insert  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation site  
,WARNING:  
, The National Fuel Gas Code  
restricts installations of gas  
appliances in garages. They must  
be 18 inches off the ground and  
protected by a barrier from  
vehicles.  
Do not install the dryer:  
- outdoors  
- in an environment with dripping  
water or weather  
- near flammable materials  
- in rooms which may contain gas  
or other fuels  
- in closets with solid doors  
- with other fuel-burning  
appliances in the same closet  
- in a location where its door  
could conflict with room doors.  
- next to a refrigerator  
- under a countertop  
- on top of a washer.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation site  
Confined space installation  
Minimum installation clearance  
^ When installed in any space with less  
than 122 square feet, minimum  
clearances around the dryer must be  
adhered to for proper ventilation and  
vents for make up air must be  
installed.  
^ Do not install any other fuel-burning  
appliance in the same space as the  
dryer.  
Confined door openings  
Any doors limiting circulation must be  
louvered or otherwise ventilated.  
A minimum of 200 square inches  
(1,290 cm2) of opening is required. It  
must be equally divided within 12"  
(30.5 cm) from the top and bottom of  
the door.  
Sides: 0 " (0 cm)  
Top: 12" (30.5 cm)  
Rear: 0" (0 cm) (as close to wall as  
gas connection and venting allows)  
Front to door: 2" (5 cm)  
Make sure the dryer door can open  
completely once installed.  
Exhaust duct clearance  
to combustible material: 2" (5 cm)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Transporting the dryer to the  
installation site  
Level the dryer  
The rear of the lid has a handle for  
transportation.  
^ Use the front dryer feet and the rear  
of the lid to move the dryer to the  
installation site.  
The dryer must be level to ensure safe  
and proper operation.  
^ Unscrew the four feet as necessary  
by turning the foot, 1, and the locking  
ring, 2, to the left.  
^ Once level, hold the foot, 1, still with  
a wrench. At the same time, turn the  
locking ring, 2, to the right using  
another wrench.  
,The dryer lid cannot be  
removed.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
,WARNING  
Before installation, disconnect the  
tumble dryer from the electrical  
supply by shutting off the power  
main or tripping the circuit breaker.  
Be sure the dryer power cord is  
unplugged from the wall.  
Do not restore power until the  
installation is complete.  
Turn the dryer’s gas shutoff valve in  
the supply line to the OFF position.  
Disconnect and discard old flexible  
gas connector and ducting material.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical connection  
The dryer is supplied with a 5’ 7"  
(1.7 m) 3x14 AWG cord and a  
NEMA 5-15 P plug, ready for  
connection to a 120 V, 60 Hz, 15 A AC  
power supply.  
,GROUNDING INSTRUCTIONS  
This appliance must be grounded.  
In the event of malfunction or  
breakdown, grounding will reduce  
the risk of electric shock by  
^ Plug the machine into a proper outlet.  
providing a path of least resistance.  
This appliance is equipped with a  
cord having an equipment  
If the plug does not fit, have a proper  
outlet installed by a qualified  
electrician.  
grounding conductor and a  
grounding plug. The dryer, when  
installed, must be electrically  
grounded in accordance with local  
codes, or in the absence of local  
codes, with the National Electrical  
Codes ANSI/NFPA 70, or the  
Canadian Electrical Code, CSA  
C22.1.  
WARNING – Improper connection of  
the equipment grounding conductor  
can result in a risk of electric shock.  
Check with a qualified electrician,  
service representative or personnel  
if you are in doubt as to whether the  
appliance is properly grounded.  
,WARNING – This dryer is  
equipped with a three-prong  
(grounding) plug for your protection  
against shock hazard and should be  
plugged directly into a properly  
grounded three-prong receptacle.  
Do not cut or remove the grounding  
terminal from this plug.  
Do not modify the plug! If it will not  
fit the outlet, have a proper outlet  
installed by a qualified electrician.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas connection  
Gas type  
,WARNING  
The gas dryer is equipped for  
connection to a NATURAL GAS  
supply.  
Installation and service must be  
performed by a qualified installer,  
service agency or gas supplier.  
The maximum heat output is  
19,500 BTU/H (5,7 kW).  
In Massachusetts a licensed  
plumber / gas fitter is required.  
An installation kit for conversion from  
NATURAL to LP gas is available as an  
optional accessory.  
This appliance must be installed  
with its own shut off valve in the  
same room. The valve must be  
easily accessible to the consumer to  
turn on or shut off the gas supply  
after the appliance is installed.  
A conversion to LP gas must only be  
carried out by a Miele Authorized  
Service Provider and in accordance  
with all local codes and ordinances.  
Minimum gas supply pressure  
to obtain the required gas input is:  
0.15 psi (4" WC) for natural gas  
0.29 psi (8" WC) for LP gas.  
During any pressure testing of the  
gas system this appliance must be  
disconnected from the gas supply  
by closing its individual manual shut  
off valve.  
Maximum gas supply pressure  
before the gas pressure regulator  
0.37 psi (10" WC) for natural gas  
0.46 psi (13" WC) for LP gas.  
Any pipe connections must be made  
using a thread sealant approved for  
gas connections. Failure to correctly  
install these items could lead to a  
gas leak and subsequent explosion.  
The gas installation must be made in  
accordance with local codes or, in  
the absence of local codes, with  
-National Fuel Gas Code,  
ANSI Z223.1/NFPA 54 for USA  
or  
-Natural Gas and Propane  
Installation Code,  
CSA B149.1 for Canada.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas connection  
Gas supply  
Installation material (hoses and  
adapters) must be provided by the  
installer.  
Gas connection distances  
aFlare union adapter  
b1/8" NPT pressure tapping plug  
cGas shut-off valve  
For convenience (if allowed by code),  
an AGA or CGA approved flexible  
stainless steel gas hose (accordion  
type) may be used between the gas  
source and the dryer. This will allow the  
appliance to be moved from the  
installation site for cleaning or  
This appliance must be installed with its  
own shut off valve on the gas supply  
line. The valve must be within 6 ft.  
(1.8 m), and in the same room, of the  
dryer.  
servicing. Make sure that nothing rubs  
on the gas hose.  
An 1/8" NPT pressure tapping plug must  
be installed immediately upstream of  
the gas supply connection. This allows  
the gas inlet pressure to be checked.  
If there is any doubt concerning  
installation, contact the Miele Technical  
Service Department at the phone  
number listed on the back of this  
manual.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas connection  
,
To secure all connections use  
appropriate Teꢀon tape or a thread  
compound.  
Use a 10" slip joint wrench only.  
^ Install a 3/8" ꢀare union adapter, a , to  
the female elbow, b .  
Hold the elbow with a wrench.  
The maximum amount oꢁ orce used  
should be 531 lbꢂ n. (60 Nm).  
^ At the end of the dryer's gas  
connection hand screw on the  
3/8" NPT elbow.  
Using a wrench tighten the elbow  
with a half turn.  
^ Secure the gas connection with  
Teꢀon tape or thread compound.  
^ Secure the ꢀexible metal gas line  
connector to the adapter.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas connection  
^ Using two wrenches tighten all  
connections.  
^ Using two wrenches tighten the  
flexible gas line connection.  
,DO NOT OVERTIGHTEN.  
^ Connect the flare union adapter, a,  
to the pressure tapping plug, b,  
originally installed on the gas shut off  
valve, c.  
^ Open the gas shut-off valve.  
^ After connecting the appliance  
check all fittings for gas leaks e.g.  
with soapy water or an equivalent.  
,WARNING  
NEVER USE AN OPEN FLAME TO  
TEST FOR GAS LEAKS.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Exhaust ducting and  
connections  
,WARNING  
A gap of 3/8" (10 mm) must be  
provided between the machine and  
the floor. This gap is necessary for  
proper air flow and must not be  
blocked by a toe-kick or thick piled  
carpets.  
Danger of toxic fumes.  
The exhaust gases from the dryer  
must only be vented outside the  
building.  
DO NOT terminate the exhaust  
ducts in a chimney, fireplace  
ducting, a combustion appliance  
vent flue, or enclosed,  
Sufficient venting of the installation  
site is essential for proper dryer  
operation. Inadequate ventilation will  
increase energy use and drying  
times.  
unventilated area such as attics,  
garages, crawlspaces, walls,  
ceilings or concealed space of a  
building.  
To reduce the risk of fire, only use  
metal ductwork.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
How to calculate the effective  
duct length  
Tips about the ductwork  
– Check with your local building code  
to determine the maximum allowable  
duct length.  
The overall duct length will determine  
the duct diameter.  
– Rigid metal or flexible aluminum  
ducting is preferred. Flexible foil  
ducting may move and bounce due  
to the high airflow of the dryer. This  
could lead to a thumping or grinding  
noise.  
^ Measure the actual duct length  
needed to go from the dryer’s  
exhaust connection to the vent outlet:  
1. Establish the number of elbows or  
bends necessary, noting the type of  
bend, angle and radius involved  
(see Table).  
– Non-metallic flexible hose should not  
be used. It is a potential fire hazard.  
2. Add the additional duct length (as  
derived by using the values  
specified in the table) to the actual  
duct length to get the effective  
length.  
– For best drying results avoid extra  
long ducting with too many bends,  
angles or tight corners.  
– The shorter the exhaust ductwork,  
the more efficient the dryer will be.  
Expelled air is slowed down in the  
ducts due to friction against the inner  
walls. The shorter and smoother the  
inner walls are, the less friction will  
be created.  
Note:  
Maximum effective duct lengths:  
4" (100 mm) diameter  
5" (125 mm) diameter  
6" (150 mm) diameter  
66 ft (20 m)  
131 ft (40 m)  
328 ft (100 m)  
– An elbow or bend creates more  
friction than a straight duct. An  
additional duct length factor must be  
added for each elbow or bend (see  
Table). This factor expresses the  
resistance of the bend in terms of a  
straight length of duct.  
Effective duct lengths over 66 ft (20 m)  
require a larger duct diameter.  
Longer ducts may lead to decreases in  
dryer efficiency if the next larger duct  
diameter is not followed.  
The additional length factor is then  
added to the existing duct to give the  
effective duct length.  
A larger duct diameter helps to  
reduce friction. Therefore duct  
diameter should be increased if  
longer duct lengths are required.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Additional duct lengths (4" (100 mm) rigid pipe only)  
Type of bend  
Radius  
inches  
Additional duct length  
cm  
ft  
cm  
Flexible metal duct  
– 3’ 3" (1 m) straight  
– 45° angle  
5’ 11"  
4’ 11"  
8’ 2"  
180  
150  
250  
10"  
10"  
25  
25  
– 90° angle  
Smooth metal duct  
– 3’ 3" (1 m) straight  
– 45° angle  
3’ 3"  
1’ 11"  
2’ 7"  
100  
60  
10"  
10"  
25  
25  
– 90° angle  
80  
Elbow 90° sharp  
7’ 6"  
2’ 4"  
230  
Concertina bend  
– 90° angle  
8"  
20  
70  
Wall vent or window vent  
– with louvers  
12’ 5"  
4’ 11"  
19’ 8"  
380  
150  
600  
– with flap  
– with weather hood  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Example  
Rigid pipe  
A
Duct length  
ft  
Duct length  
m
12’ 5"  
3.8 m  
Wall duct with  
louvered wall vent  
B
C
D
2’ 4"  
1’ 7"  
0.7 m  
0.5 m  
0.7 m  
5.7 m  
90° bend  
20" (0.5 m) rigid pipe  
90° bend  
2’ 4"  
Total duct  
length  
18’ 8"  
The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm)  
with adapter is sufficient.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Exhaust connection with a  
flexible exhaust hose or rigid  
pipe  
,WARNING  
Do not remove the restriction insert  
in the vent opening. It may result in  
poor drying results, damage to the  
laundry and higher Carbon  
monoxide emissions.  
Using the connector supplied, an  
exhaust hose (4" [100 mm]  
diameter) can be installed.  
Necessary materials:  
The exhaust duct must not be  
– a wall or window duct  
(available from Miele)  
connected or secured with screws  
or other fastening devices which  
extend into the interior of the duct.  
– an exhaust hose made of approved  
non-flammable material  
^ Install the required connector*, 1,  
with the exhaust hose or pipe, 2, to  
the dryer.  
* The white connector with clips is  
used for connection to a hose; the  
gray connector without clips is used  
for connection to a pipe.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Window connection (example)  
Wall connection (example)  
1 Window duct  
1 Wall pipe (Installation sheet supplied  
with the Miele wall pipe)  
2 Connector for the rigid or flexible  
exhaust hose  
2 Connector  
3 Rigid pipe  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ducting  
Direct wall connection  
Necessary materials:  
– a wall pipe  
Dryer side view  
– flexible foam gasket  
Dryer top view  
1 Wall pipe  
2 Flexible foam gasket  
1 Wall pipe  
2 Flexible foam gasket  
^ Connect the flexible foam gasket, 2,  
to the wall pipe connector, 1.  
^ Push the dryer to the wall.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caring for the environment  
Disposal of the packing  
materials  
Disposal of an appliance  
Old appliances may contain materials  
that can be recycled. Please contact  
your local recycling authority about the  
possibility of recycling these materials.  
The packing materials protect the  
appliance during shipping. They have  
been designed to be biodegradable  
and recyclable.  
Ensure that a discarded dryer presents  
no danger to children. When being  
stored for disposal remove the door to  
the drying compartment.  
To prevent suffocation, ensure that any  
plastic wrappings, bags, etc. are  
disposed of safely and kept out of the  
reach of children.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All rights reserved / 0208  
M.-Nr. 07 268 180 / 00  
For the most updated manual please see the Miele web site.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Murphy Switch TP 8318N User Manual
Mustang Survival Life Jacket MD3081 User Manual
National Instruments Digital Camera NI 1450 Series User Manual
NETGEAR Network Card EN516 User Manual
Nexus 21 Computer Hardware 1066MT s Interposer User Manual
Nokia Battery Charger DDC 1 User Manual
Nvidia Computer Hardware DG 04927 001_V01 User Manual
Opticon Barcode Reader CRD 9723 User Manual
Optoma Technology Projector TS721 User Manual
Patterson Kelley Boiler MACH 05 User Manual