Product and Cut-out Dimensions
Page 1 of 4
Location Codes
1 – Spring clips
2 – Appliance front
3 – Installation height
4 – Power supply box with connection cable, Length = 47 1/4” (1200 mm)
208 V, 60 Hz, 20 A fuse rating
240 V, 60 Hz, 15 A fuse rating
Ensure that the power outlet is accessible after installation
5 – Rating label – Ensure that the electrical supply matches the rating. Adhere rating label sticker supplied with the
appliance into the manual.
Shipping weight 18 lbs (8.1 kg)
Shipping dimensions 23” (584 mm) L x 16” (406 mm) W x 8” (203 mm) H
Notes
Indoor use
The appliance must not be permanently sealed into the countertop when installed. The sealing strip under the edge of
the appliance provides a sufficient seal for the countertop.
All installations must be done in accordance with local codes.
Drawing is not to scale
Specification Sheets OJS 02212012
Download from Www.Somanuals.com. All Manuals Search And Download.
Product and Cut-out Dimensions
Page 3 of 4
The illustration above represents the attachment of spring clips 1 and support bars 2 for 3
appliances
An additional support bar is required for each additional appliance. The position for the
attachment of an additional support bar depends on the width of appliance B.
Spring Clip installation
on wood or solid
Spring Clip installation
on a granite
surface countertop
Place the supplied
spring clips 1 and the
support bars 2 at the
marked positions as
shown above, by
countertop
Position and attach
the spring clips 1 and
the support bars 2
with strong double-
sided tape 3
laying them on the
upper edge of the cut-
out and then securing
them with the 1/8” x 1”
(3.5 x 25 mm) screws
(supplied)
Coat the side and
lower edges of the
spring clips with
silicone.
Fill the space between
the support bars and
the countertop with
silicon
Location Codes
1 – Spring Clips
2 – Support bars (Accessory, item - 27996029D CSZL 1500 (Includes cover 4))
3 – Space between support bar and countertop
4 – Cover
Notes
All installations must be done in accordance with local codes.
Drawing is not to scale
Specification Sheets OJS 02212012
Download from Www.Somanuals.com. All Manuals Search And Download.
Product and Cut-out Dimensions
Safety distances to back wall
Page 4 of 4
1 – Wall frame
2 – Wall covering
x = thickness of the wall covering
3 – Countertop
4 – Countertop cut-out
5 – Minimum safety distance
with flammable materials 2" (50 mm)
with non-flammable materials 2" (50 mm) minus x
If a wall covering is installed, a minimum safety distance must be maintained between the countertop cut-out
and the covering, since high temperatures can damage these materials.
If the covering is made of a combustible material (such as wood), the distance between the countertop cut-out
and the wall covering must be a minimum of 2" (50 mm).
For coverings made of non-combustible materials (such as metal, marble, granite or ceramic tiles) the
minimum safety distance between the countertop cut-out and the wall covering must be 2" (50 mm) minus the
thickness of the covering.
For example: thickness of wall covering 9/16" (15 mm) 2" (50 mm) - 9/16" (15 mm) = minimum safety distance
1 3/8" (35 mm).
Safety distances to surrounding cabinetry
Recommended
Not Recommended
Not Permitted
The appliance should only be installed as shown in the above illustrations while maintaining the
required safety distances shown. Do not install the appliance between two tall cabinets, this is a
fire hazard.
A distance of at least 2” (50 mm) must be kept between the countertop and the rear wall
because of high temperature radiated.
The minimum distance required from the countertop cut-out to a side wall or tall cabinet right or
left 2” (50 mm) (Location code 1)
Safety distance above the appliance
The minimum safety distance given by the hood manufacturer
must be maintained between the combiset and the hood above
it. See the installation instructions for the hood for these safety
measurements.
If the hood manufacturers instructions are not available or if
flammable objects are installed over the combiset (e.g.
cabinets, utensil rail, etc.), a minimum safety distance of 30”
(760 mm) must be maintained.
Notes
All installations must be done in accordance with local codes.
Drawing is not to scale
Specification Sheets OJS 02212012
Download from Www.Somanuals.com. All Manuals Search And Download.
|