Operating Manual ТЭ3.623.912-03РЭ is intended for studying the content, operation  
principle, parameters and characteristics of the ТМ-1104-3 ТЭ3.623.912-03 television  
module to help correct operation and full use of the technical capabilities thereof.  
For studying and operation of the ТМ-1104-3 ТЭ3.623.912-03 television module the  
following additional documents should be guided by:  
1 DESCRIPTION AND OPERATION  
1.1 Description and Operation of Device  
1.1.1 Application  
The ТМ-1104-3 ТЭ3.623.912-03 television module, hereinafter referred to as "device",  
when used as a part of the TV-complex is intended for:  
- commutation of video signals from TVDs to TVMs of the TV-complex;  
- displaying of video information from TVDs of the TV-complex on the screen of the  
ВС-2 TVM, that is built into the device;  
- generation and reception of control signals during data exchange via RCLI channels  
with the TM-1215-4 control modules and ТМ-1213 terminal module of the TV-complex;  
- generation and reception of control signals during data exchange via RCLI channels  
with the ТМ-1304 combined modules of the TV-complex;  
ТМ-1104-3 television module:  
- electric connection diagram ТЭ3.623.912-03Э4;  
- component list ТЭ3.623.912-03ПЭ4;  
- block diagram ТЭ3.623.912-03Э2.  
МТК-110МЭ television complex:  
- general electric diagram ТЭ1.133.110-02Э6;  
- block diagram ТЭ1.133.110-02Э2;  
- operating manual ТЭ1.133.110-02РЭ.  
- generation and transmission of the DGP signal to the ТМ-1304 combined modules of  
the TV-complex;  
- reception of chronometrical information from device "Гном-2МЭ", indication of that  
on the screen of the ВС-2 TVM and its transmission to the ТМ-1213 terminal module of the  
TV-complex via RCLI channel;  
The list of the special terms and abbreviations used in the present Manual is given in  
Appendix A.  
- supplying the ТМ-1304 combined modules, TM-1215-4 control modules and  
TM-1213 terminal module of the TV-complex with a feeding voltage of plus 27 V;  
- gathering and processing of information on the TV-complex state;  
- indication of information on the TV-complex state on the screen of the ВС-2 TVM;  
- indication of information on the TV-complex state with the built-in LEDs;  
- checkout of the equipment of the TV-complex during maintenance and operation.  
To provide easy restoration of the device some modules and units of the BSP are built  
immediately into the device.  
The device provides the parameters and characteristics given below under the  
following operating conditions:  
- ambient temperature from 0 to 40 °С;  
- relative humidity up to 98% at a temperature of 35 °С;  
- air pressure from 600 mm Hg to 1520 mm Hg;  
- sinusoidal vibration in a frequency range of 5 to 60 Hz at an acceleration amplitude  
of up to (2,0 ± 0,4)g.  
P.  
P.  
5
6
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1 (continued)  
Designation  
1.1.2 Main Technical Parameters  
Code  
Part Name  
Qty.  
The device has the following main technical parameters:  
- number of video signal inputs - 21;  
- number of video signal outputs - 4;  
- swing of input and output video signals - (1 ± 0,3) V;  
- load resistance in video signal circuit - (75 ± 5%) ;  
- video channel bandwidth, at least 7,3 MHz;  
ТЭ3.057.439-01 ЭМ-1209-1  
ТЭ3.679.117-01 ЭМ-1212-1  
ТЭ5.883.022  
Controller  
1
1
1
Control module  
Assembly unit  
- scanning - interlaced, 625 lines, 25 frames a second;  
- number of RCLI channels for data exchange with the TM1215-4 control module and  
ТМ-1213 terminal module - 4;  
1.1.4 Device Structure and Operation  
- number of RCLI channels for data exchange with the ТМ-1304 combine modules - 6;  
- lock mode - autonomous;  
- number of DGP output signals - 6;  
- two independent channels for receiving chronometrical information from device  
"Гном-2МЭ";  
- supply voltage - three-phase, from 180 to 231 V;  
- feeding voltage frequency - (50 ± 1) Hz;  
- power consumption - no more than 500 VA, including total power consumption of  
external load not exceeding 350 VA;  
Modules and units of the device form several functional systems, that are parts of the  
corresponding systems of the TV-complex. This functional systems are listed below:  
- system providing generation, processing and displaying of video signals;  
- genlocking system;  
- control system;  
- automated checkout system;  
- chronometrical information input system;  
- power supply system;  
- continuous operation time - 5000 h;  
- overall dimensions – no more than 1722 x 360 x 629 mm;  
- weight, maximum - 125 kg.  
- auxiliary communication system.  
Most modules included by the device contain units that are parts of different systems.  
The description of the device and operation thereof refers to elements in the  
ТМ-1104-3 ТЭ3.623.912-03Э4 TV-module electric connection diagram and the  
ТЭ1.133.110-02Э6 TV-complex general electric diagram.  
1.1.3 Device Contents  
The device includes the parts shown in Table 1.  
Table 1  
1.1.4.1 Video Signal Generation, Processing and Displaying System  
The system of video signal generation, processing and displaying provides:  
- “mirror” rotation of the image arriving from the KT-257 TV-camera;  
- multiplexing of 21 input video signals to five outputs;  
Designation  
Code  
Part Name  
Television monitor  
Qty.  
- generation of a video signal for displaying information on the TV-comlex state on the  
ВС-2 TVM;  
- displaying of video information from the TVDs of the TV-complex on the screen of the  
ВС-2 TVM.  
The device contains three main modules of the video signal generation, processing  
and displaying system:  
ТЭ2.045.544  
ТЭ2.067.408  
ТЭ2.072.492  
ТЭ2.201.769  
ВС-2  
1
6
1
3
1
1
1
ФСП-3В  
ЭМ-1211  
ЭМ-1213  
Interference rejection filter  
Diagnostics module  
Power supply unit  
Videoswitch module  
Videoswitch module  
Interface unit  
- videoswitch module, ЭМ-1204-1 (А31);  
- videoswitch module, ЭМ-1205-1 (А32);  
- ВС-2 television monitor (А11);  
ТЭ2.242.434-01 ЭМ-1204-1  
- ЭМ-1211 diagnostics module (А21) that generates the video signal containing data  
on the TV-complex state.  
ТЭ2.242.435-01 ЭМ-1205-1  
ТЭ2.275.261  
ЭМ-1242  
The ЭМ-1205-1 videoswitch module converts the inverse image from the KT-257  
TV-camera (created by the lens of pull-out optical device “Сигнал-3”) to an erect image. The  
ЭМ-1205-1 videoswitch module provides several modes of image rotation: by line, by frame  
and by both at the same time. The rotation mode is set by parallel binary code that is used for  
remote control. The code comes from the ЭМ-1204-1 videoswitch module.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
7
8
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The video signal from the KT-257 TV-camera comes to connector X1 of the device  
and then – to the input of the ЭМ-1205-1 videoswitch module. The ЭМ-1205-1 videoswitch  
module contains a DAC, an ADC and a PLIC. The ADC performs conversion of the analog  
video signal into a digital one. Then, the PLIC provides writing of the data into the internal  
RAM and reading the content of the RAM in an inverse order thereby performing the image  
rotation required. The rotation process is initiated on a remote control command. From the  
output of the PLIC the digital data come to the DAC that does the conversion into an analog  
output video signal.  
The ЭМ-1204-1 videoswitch module performs multiplexing of 21 input video signals to  
five outputs in accordance with remote control commands that come from the ЭМ-1209-1  
controller via RCLI lines.  
The ЭМ-1204-1 videoswitch module contains an analog matrix multiplexer providing  
commutation of 24 input signals to 6 outputs. The device employs only 21 inputs and five  
outputs. The matrix multiplexer is driven by a built-in microcontroller (MC) receiving  
commands from the ЭМ-1209-1 controller.  
The video signal from the output of the ЭМ-1205-1 videoswitch module comes to input  
1 of the ЭМ-1204-1 videoswitch module. The signals from the TVDs of the TV-complex are  
connected to inputs 2 to 20. "Video Input 21" of the ЭМ-1204-1 videoswitch module is  
reserved and not used in the TV-complex. The output video signals of the ЭМ-1204-1  
videoswitch module are assigned as follows:  
"Video Output 1" via connector X22 of the device comes to TVM ВС-2-1 No.1 of the  
TV-complex (first CP of TV-complex);  
"Video Output 2" via connector X23 of the device comes to TVM ВС-2-1 No.2 of the  
TV-complex (second CP of TV-complex);  
"Video Output 3" via connector X24 of the device comes to the ВС-1-1 No.1 of the TV-  
complex (third CP of the TV-complex);  
"Video Output 4" comes to connector X25 of the device and is not used in the TV-  
complex;  
"Video Output 5" comes to the video input of the ЭМ-1211 diagnostics module and  
then - to the ВС-2 TVM.  
The ЭМ-1211 diagnostics module performs switching between video signals for the  
ВС-2 TVM coming from the ЭМ-1204-1 videoswitch module and a diagnostics signal that is  
generated by the ЭМ-1211 diagnostics module by itself.  
Commutation of video signals is done by pressing the buttons on the front panel of the  
ЭМ-1211 diagnostics module. By pressing button SELECT the video signal from the  
ЭМ-1204-1 videoswitch module (from the TVD chosen on the ЭМ-1212-1 control module) is  
connected to the ВС-2 TVM. Pressing button ENTER provides connection of the video signal  
formed in the ЭМ-1211 diagnostics module, containing data on the TV-complex state, to the  
screen of the ВС-2 TVM.  
The main unit of the genlocking system is the EM-1209-1 controller. The PLIC of the  
unit forms the DGP signal basing on clock pulses of a quartz oscillator and supplies it to the  
six DGP outputs via a buffer amplifier. This signals are fed to connectors X26-X31 of the  
device and finally arrive to the TM-1304 combined modules. One DGP output (connector  
X31) is reserved and not used in the TV complex.  
1.1.4.3 Control System  
The functional control system (CS) is formed by the ЭM-1209-1 controller (A33) along  
with microcontrollers and microprocessors of the main device modules interconnected via  
RCLI lines. The ЭM-1209-1 controller constitutes a dedicated computer performing the main  
control functions of the TV complex. The microcontrollers and microprocessors that are parts  
of the ЭM-1204-1 videoswitch module (А31), ЭМ-1211 diagnostics module (А21), ЭM-1212-1  
control module (А22), and ЭM-1242 interface unit (А23) perform local control functions.  
The control system provides:  
- communication with the TM-1215-4 control modules and the TM-1230 control module  
of the TV complex CPs to receive control instructions from the module buttons;  
- input of control instructions from the ЭM-1212-1 control module, that is a part of the  
device, during the TV complex operation check.  
- processing of control instructions and output of instructions to the execution units of  
the device and other modules of the TV complex to provide power supply and control of the  
TVDs, correction and commutation of video signals, centralized genlocking and video  
recording.  
- receiving and analysis of replies of execution units and indication of instruction  
fulfillment results;  
- preparation and output of data about the state of the TV-complex to the automatic  
checkout system (ACS).  
The ЭM-1209-1 controller is the main control element of both the device control  
system and the whole TV complex. The working software of the controller is written to ROM  
and provides control of the TV complex via serial duplex communication channels. The  
ЭM-1209-1 controller incorporates a power supply supervisor and a watchdog timer,  
controlling the working program execution and automatically resetting the system in case of a  
fault. The ЭM-1209-1 controller provides 14 serial duplex interface channels (RCLI) and an  
RS-232 channel. The working program can be reset by pressing the RESTART button,  
mounted on the front panel of the controller. The ЭM-1209-1 controller is installed on the third  
floor of the device in the rightmost row (see Appendix B, pos.13). To the left of that the two  
ЭM-1209-1 controllers of the BSP are installed.  
The modules that are parts of the device as well as other modules included by the  
TV-complex are controlled via RCLI channels.  
The RCLI channels have the following parameters:  
1.1.4.2 Genlocking System  
- loop-type channel, duplex, four-wire, two wires are used for output datastreams (data  
transmission lines) and two wires are used for input datastreams (data reception lines);  
- data transmission and reception circuits are galvanically decoupled;  
- baud rate - 19200;  
The genlocking system provides centralized synchronization of all the TVDs of the  
complex by forming DGP signals on the six output connectors of the device. The DGP signal  
constitutes a pulse sequence with a swing of 3 V, frequency of 15625 Hz and duration of  
5 µS. Every 625-th pulse has a duration of 12 µS. The centralized synchronization reduces  
the mutual interference level and simplifies video signal processing.  
- number of data bits - 8;  
- number of stop bits – 1;  
- LSB is transferred first;  
- pause, stop bit and logic one are transferred as current from 0 to 1 mA;  
- start bit and logic 0 are transferred as current from 15 to 25 mA;  
P.  
P.  
10  
9
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- receiver operation threshold is from 5 to 8 mA.  
Channel " RCLI 14" is used for data exchange between the ЭМ-1209-1 controller and  
the ЭМ-1204-1 videoswitch module. The command array contains instructions for  
commutation of the input video signals to the six outputs. The reply array contains  
information on the instruction execution.  
Channels " RCLI 6" and " RCLI 10" are brought out to connectors X37 and X39 of the  
device. They are reserved and not used in the TV-complex.  
Data in the RCLI channels is transmitted as byte arrays. Data arrays are transferred  
with a frequency from 10 to 25 Hz. The pause between arrays is no less than 1 ms. Pause  
between neighboring bytes within an array is no more than 100 µS. Every array ends with a  
check sum. Data exchange in RCLI channels is started by the ЭМ-1209-1 controller by  
transmission of the corresponding command instruction arrays. On reception of the command  
instruction array all the units and modules of the TV-complex start transmission of reply  
arrays.  
The RS-232 channel is brought out on connector X43 of the device. This channel is  
used for setup and debugging of the TV-complex.  
The ЭМ-1209-1 executes the program stored in its non-volatile memory. This program  
periodically, with a frequency of 10 to 25 Hz, carries out the following actions:  
- communication with the ТМ-1215-4 control modules, TМ-1230 control module and  
ЭМ-1212-1 control module via the RCLI channels;  
Data exchange between the ЭМ-1209-1 controller and the ТМ-1304 No.1 -  
ТМ-1304 No.5. combined modules is performed via channels " RCLI 1" – " RCLI 5". During  
this exchange the datastream passes through assembly modules, ТМ-1308 No.1-  
ТМ-1308 No.3.  
- handling of commands coming from the ТМ-1215-4 control modules, TМ-1230  
control module and ЭМ-1212-1 control module when their buttons are pressed;  
- forming of control instructions for all the modules connected to the ЭМ-1209-1 via the  
RCLI channels.  
- transferring of instructions via the RCLI channels and interrogation of the ЭМ-1204-1  
video signal commutation module, ЭМ-1242 interface module, ЭМ-1202 control and  
synchronization modules in the ТМ-1304 combined modules, ЭМ-1241 control modules in  
the ТМ-1220-1 optical TV-units and the КТ-257 TV camera;  
- forms and transfers the diagnostic data to the ЭМ-1211 diagnostics module.  
The ЭМ-1212-1 control module (Fig.1) provides manual command input for the  
ЭМ-1209-1 controller with the buttons mounted on the front panel and LED indication of  
execution of the following commands:  
- switching on and off of any of the 20 TVDs of the TV-complex with buttons GROUP1-  
GROUP5, CHANNEL1-CHANNEL4, OFF.  
- enabling the night mode of the KT-257 TV-camera with button NIGHT MODE;  
- control of the selected ТМ-1220-1 optical TV-module with button TEST ON.  
- indication of location of faulty TVDs under servicing or servicing completion with  
buttons TVD TO CHECK and TVD FROM CHECK.  
- testing LEDs and buttons of the ЭМ-1212-1 control module with button TEST of the  
ЭМ-1212-1.  
Every command array consists of nine bytes and contains the following data:  
command to switch on the power supplies of four TVDs, video signal correction factors for  
four TVDs, type of synchronizing pulses and delay of those for synchronization of four TVDs,  
instructions for control of TVD modes. The reply arrays contain data on functioning of the  
modules that are parts of the ТМ-1304 combined modules, supply voltage presence on four  
TVDs, presence of video signals from four TVDs, diagnostic information from four TVDs.  
Data exchange between the ЭМ-1209-1 controller and the ТМ-1213 terminal module  
is performed via channel " RCLI 7". During this exchange the datastream passes through  
connector X38 of the device and the ТМ-1308 No.4 assembly module.  
The command array contains commands to light up the LEDs of the ТМ-1215-4 No.1  
and the ТМ-1230 control modules, commands for control of the ДЕ-118-1 VRD, data for  
mixing into the video signal before video recording (abbreviated name of TVD, date and  
time). The reply array contains the codes of the buttons pressed on the control modules,  
ТМ-1215-4 N 1 and ТМ-1230, and also information about the state of the ДЕ-118-1 VRD.  
Data exchange between the ЭМ-1209-1 controller and the ТМ-1215-4 No.2 control  
module is performed via channel " RCLI 8". During this exchange the datastream passes  
through connector X38 of the device, the ТМ-1308 No.4 assembly module and the ТМ-1201  
No.1 terminal module. The command array contains commands to light up the LEDs of the  
ТМ-1215-4 No.2 control module. The reply array contains the codes of the buttons pressed.  
Data exchange between the ЭМ-1209-1 controller and the ТМ-1215-4 No.3 control  
module is performed via channel " RCLI 9". During this exchange the datastream passes  
through connector X39 of the device, the ТМ-1308 No.5 assembly module and the  
ТМ-1201 No.2 terminal module. The command array contains commands to light up the  
LEDs of the ТМ-1215-4 No.3 control module. The reply array contains the codes of the  
buttons pressed.  
The ЭМ-1209-1 controller transmits data to the ЭМ-1211 diagnostics module via  
channel " RCLI 11". The data array contains information on data transfers between the  
ЭМ-1209-1 controller and all the peripheral modules, information on the state and control of  
all the TVDs and VRDs.  
Channel " RCLI 12" is used for data exchange between the ЭМ-1209-1 controller and  
the ЭМ-1212-1 control module. The command array contains instructions for controlling the  
LEDs of the ЭМ-1212-1 control module. The reply array contains the codes of the buttons  
pressed.  
Channel " RCLI 13" is used for data exchange between the ЭМ-1209-1 controller and  
the ЭМ-1242 interface module. The command array contains a request for transferring  
chronometrical information from the first or the second channel of the ЭМ-1242 interface  
module. The reply array contains chronometrical information from the requested exchange  
channel of the ЭМ-1242 interface module.  
P.  
P.  
12  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
11  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2  
Group-  
channel  
Video signal  
source  
Designation on  
Place of TVD installation  
Device Сигнал-3″  
ТМ-1215-4  
ЭМ-1212-1  
1-1  
1-2  
1-3  
1-4  
2-1  
2-2  
2-3  
2-4  
3-1  
КТ-257  
PERISCOPE  
FE –6FR  
1R 1D STB  
1R 2D  
TROUBLE  
ЭМ-1204-1  
ЭМ-1205-1  
ЭМ-1209-1  
ЭМ-1242  
GROUP  
CHANNEL  
TVD CONTROL  
TROUBLE  
ТМ-1304 N1  
ТМ-1304 N2  
ТМ-1304 N3  
ТМ-1304 N4  
ТМ-1304 N5  
ТМ-1220-1  
Fore end, 6 frame  
1 room, 1 deck, starboard side  
1 room, 2 deck  
NIGHT  
MODE  
1
2
1
Неотон-08-2  
Неотон-08-1  
Неотон-08-1  
ТМ-1220-1  
TEST  
ON  
2
3
1 room, 1 deck, port side  
Superstructure, 20 frame  
3 room, 1 deck  
1R 1D PS  
SUPRSTR 20FR  
3R 1D  
TVD TO  
CHECK  
3
4
ЭМ-1213 N1  
ЭМ-1213 N2  
ЭМ-1213 N3  
TVD  
FROM CHECK  
4
5
Неотон-08-2  
Неотон-08  
ТМ-1215-4 N1  
ТМ-1215-4 N2  
ТМ-1215-4 N3  
3 room, 3 deck  
3R 3D  
FUSE  
4 room, 1 deck  
Неотон-08-2  
4R 1D  
BF, winch automated communication  
system  
3-2  
ТМ-1220-1  
WINCH ACS  
OFF  
ТМ-1213  
TEST ЭМ-1212-1  
3-3  
3-4  
4-1  
4-2  
4-3  
4-4  
5-1  
5-2  
5-3  
5-4  
4 room, 2 deck, starboard  
4 room, 2 deck, port side  
5 room, port side  
Неотон-08-1  
Неотон-08-1  
Неотон-08-2  
Неотон-08-2  
ТМ-1220-1  
4R 2D STB  
4R 2D PS  
5R PS  
МТК-110МЭ  
ДЕ-118-1  
5 room, starboard  
5R STB  
Pod, winch sonar system  
4 room, 2 deck, PCS  
6 room, 1 deck, aft  
6 room, 1 deck, fore  
Tiller compartment  
Pod, 108 frame  
WINCH SS  
4R 2D PCS  
6R 1D A  
6R 1D F  
TC  
Fig. 1 – Front panel of the ЭМ-1212-1 control module.  
Неотон-08  
Functioning of the ЭМ-1212-1 control module as a part of the control system is  
provided by microcontroller CS, PLIC, interface and buttons with LEDs. The microcontroller  
(MC) together with the PLIC inquires the buttons. On request from the ЭМ-1209-1 controller  
the MC forms a reply array with the codes of the buttons pressed and transfers it via the  
RCLI channel to the ЭМ-1209-1 controller.  
The MC of CS receives from the ЭМ-1209-1 controller a command array with  
instructions for lighting up the LEDs and switches on the corresponding LEDs by means of  
the PLIC. The working program of the ЭМ-1209-1 controller analyses the button state and  
decides whether to light up the LEDs.  
Неотон-08-1  
Неотон-08-1  
Неотон-08  
ТМ-1220-1  
POD 108FR  
The ЭМ-1242 interface unit contains a MC and a PLIC that form an array with  
chronometrical data on request from the ЭМ-1209-1 controller.  
Correspondence between group numbers, channel numbers, TVD installation places  
and the designation on the ТМ-1215-4 control module is shown in Table 2.  
The ЭМ-1211 diagnostics module has a microprocessor and an interface receiving  
arrays with data on the CS state from the ЭМ-1209-1 controller and provide visualization of  
the data in video frames of the ACS.  
The ЭМ-1204-1 videoswitch module contains a MC and an interface that receive  
instructions from the ЭМ-1209-1 controller for commutation of video signals and control their  
execution.  
The ЭМ-1209-1 controller working program provides various priorities for the  
ЭМ-1212-1 and ТМ-1215-4 control modules as per enabling and control of the TVDs. The  
ЭМ-1212-1 control module has the highest control priority. The second comes the  
ТМ-1215-4 No.1 control module, then - the ТМ-1215-4 No.2 control module and  
ТМ-1215-4 No.3 control module.  
The ЭМ-1209-1 prohibits accidental enabling the night channel of the KT-257  
TV-camera in the day time. On the first press on button PERISCOPE NIGHT on any of the  
ТМ-1215-4 control modules, the ЭМ-1209-1 controller will switch on the day channel of the  
P.  
P.  
ТЭ3.623.912-03РЭ  
14  
ТЭ3.623.912-03РЭ  
13  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
KT-257 TV-camera. If button PERISCOPE NIGHT is pressed again the night channel of the  
KT-257 TV-camera will be switched on in at least 5 s since the day channel switch-on. If the  
night channel of the KT-257 TV-camera has already been switched on and button  
PERISCOPE NIGHT on the other ТМ-1215-4 control module is pressed, the signal of the  
night channel will be connected to the TVM without delay.  
The ЭМ-1209-1 controller prohibits the TM-1215-4 control module with the lowest  
priority from execution of the following control commands:  
- input a test into the TM-1220-1 optic-television module if it was already switched on  
from the ЭМ-1212-1 control module or from a ТМ-1215-4 control module having a higher  
priority;  
ЭМ-1211  
TROUBLE  
ENTER  
- switch on the day channel of the KT-257 TV-camera if the night channel was  
switched on from the ЭМ-1212-1 control module or from a ТМ-1215-4 control module having  
a higher priority;  
- switch on the night channel of the KT-257 TV-camera if the day channel was  
switched on from the ЭМ-1212-1 control module or from a ТМ-1215-4 control module having  
a higher priority;  
SELECT  
The ЭМ-1209-1 controller prohibits to switch on the KT-257 TV-camera and the  
TM-1220-1 optic-television modules from the ТМ-1215-4 No.3 control module. If an attempt  
at switching on this units occurs, light-emitting diode NO TVD lights up on the  
ТМ-1215-4 No.3 control module.  
RESTART  
The ЭМ-1209-1 prohibits to enable video recording from the ТМ-1215-4 No.2 и  
ТМ-1215-4 No.3 control modules. On pressing button RECORD ON on this modules light-  
emitting diode NO CTRL lights up.  
The ЭМ-1209-1 prohibits controlling the ДЕ-118-1 VRD from the front panel of the  
TM-1230 control module, if prior to that the registration mode was activated on the  
ТМ-1215-4 No.1 control module.  
A TVD generating an abnormal image undergoes checking and servicing. The  
ЭМ-1209-1 controller provides indication of the servicing mode from the ЭМ-1212-1 control  
module with recording the number of the ТМ-1215-4 control module from which the TVD was  
forwarded for servicing. During this the power supply remains connected to the TVD and the  
video signal of the TVD comes to the corresponding TVM. On enabling the TVD under  
servicing from any of the ТМ-1215-4 control modules or ЭМ-1212-1 control module light-  
emitting diode TVD TO CHECK lights up thereon.  
Fig. 2 – Front panel of ЭМ-1211 diagnostics module.  
The ЭМ-1211 diagnostics module constitutes a special computer whose working  
software is written into the ROM by Manufacturer. It has a built in power supply supervisor  
and a watchdog timer automatically controlling the working program execution and resetting  
the system in case of a fault. The ЭМ-1211 diagnostics module includes a video adapter  
forming the video signal and a switch connecting either the external signal or the adapter  
signal to the common output. The 55-channel ADC measures the incoming d.c. voltages from  
minus 30 to plus 30 V with a ratio error of no more than 0,2%. The ЭМ-1211 diagnostics  
module has an RS-232 and a RCLI interface channels. There are five buttons and one LED  
on the front panel of the ЭМ-1211 diagnostics module (Fig.2). The LED indicates a fault in  
the TV-complex. Button ENTER outputs the ACS frame No.1 on the ВС-2 TVM screen. The  
arrow buttons allow switching between frames of the ACS. Button SELECT switches the  
video signal from the ЭМ-1204-1 videoswitch module to the screen of the ВС-2 TVM. Button  
RESTART forces reset of the working program. The ЭМ-1211 diagnostics module is installed  
on the second floor of the device in the leftmost row (Fig. B1, pos.3).  
The ЭМ-1209-1 controller allows to take a TVD out of servicing only from the  
ЭМ-1212-1 control module panel.  
1.1.4.4 Automated Checkout System  
The automated checkout system (ACS) is intended for continuous supervision over  
the state of all the modules and units of the device, gathering of data on the state of units and  
modules of the TV-complex. The ACS analyses the incoming data and indicates the state of  
the TV-complex modules and units by means of the LEDs and the screen of the ВС-2 TVM.  
The ЭМ-1211 diagnostics module (А21) is the main module of the ACS of the device  
and the TV-complex also. The ACS comprises the following modules of the device:  
- ЭМ-1212-1 control module (А22);  
- ЭМ-1209-1 controller (А33);  
- ВС-2 television monitor (А11).  
P.  
P.  
16  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
15  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The ADC of the ЭМ-1211 diagnostics module samples the d.c. voltages from the three  
ЭМ-1213 power supply units, outputs of fuses F1-F16, power supply units built into the  
device modules and control voltages +27V from connectors X38 and X39. The ЭМ-1211  
diagnostics module measures these voltages and finds faulty modules that fall out of the  
corresponding tolerances.  
STATE OF МТК-110МЭ  
ТМ–1104–3  
Via a RCLI channel the diagnostics module receives data from the ЭМ-1209-1  
controller on the state of the TV-complex units and modules. This information is prepared  
during data exchanges via the RCLI channels and contains data on the presence of feeding  
voltages and video signals, character of data exchanges between different modules of the  
TV-complex, state of the TVDs, VRDs and the ТМ-1215-4 control modules. The ЭМ-1211  
diagnostics module transfers data for light indication of faulty units and modules to the  
ЭМ-1212-1 control module via a separate RCLI channel.  
The ЭМ-1212-1 control module forms three video frames of the ACS for indication of  
the TV-complex state on the screen of the ВС-2 TVM.  
The ACS frame No.1, "STATE OF МТК-110МЭ" (Fig.3), is formed on pressing button  
ENTER. In this frame enabled modules and units are shown as their codes against a light  
background, disabled – as theirs codes against a dark background and faulty ones – as their  
codes against a blinking background.  
The states of the main modules and fuses F1-F16 of the device are shown in the  
upper part of the frame. The state of the ТМ-1215-4 No. 1- ТМ-1215-4 No.3 control modules  
is shown below. The ТМ-1215-4 No.1 interacts with the ТМ-1213 terminal modules having  
the ЭМ-1240 interface unit therein and the ДЕ-118-1 VRD. This devices are grouped  
together in the frame. Near the ДЕ-118-1 VRD its state is shown. The following states of the  
VRD are shown: "STOP", "OFF", "RECORD", "PLAY", "PAUSE", "REWIND <<", "FAST  
FORWARD >>", "NO VIDEO CASSETTE", "VRD TROUBLE", "NO CONTROL".  
ЭМ–1212-1  
F1 F2  
ЭМ–1242  
ЭМ–1204-1  
ЭМ–1205-1  
F14  
ЭМ–1209-1  
F16  
F15  
F6 F7 F8  
F3  
F5  
F11  
F12  
F10  
F4  
F9  
F13  
ЭМ–1213 N2  
ЭМ–1213 N3  
ЭМ–1213 N1  
ТМ–1215–4 N1  
ТМ–1213  
ЭМ–1211  
ТМ–1215–4 N2  
ТМ–1215–4 N3  
ЭМ–1240  
ДЕ–118–1=> NO VIDEO CASSETTE  
ТМ–1304 N1  
ТМ–1304 N5  
ЭМ-1202  
ТМ–1304 N2  
ТМ–1304 N3  
ЭМ-1202  
ТМ–1304 N4  
ЭМ-1202  
ЭМ–1202  
ЭМ-1203  
БПИ–183-а  
PERISCOPE  
FE–6FR  
ЭМ-1202  
ЭМ-1203  
ЭМ-1203  
ЭМ-1203  
ЭМ-1203  
БПИ-183-а  
1R 1D PS  
SUPRSTR 20FR  
3R 1D  
БПИ-183-а  
6R 1D A  
6R 1D F  
TC  
БПИ-183-а  
4R 1D  
БПИ-183-а  
5R PS  
WINCH ACS  
4R 2D STB  
4R 2D PS  
5R STB  
The five columns of the units related to the ТМ-1304 No.1 - ТМ-1304 No.5 combined  
modules are shown below. There are the states of the ЭМ-1202 control and synchronization  
modules, ЭМ-1203 video amplifier modules, БПИ-183-а power supply units incorporated by  
the ТМ-1304 combined modules shown togethes with the states of the four TVDs connected  
to each ТМ-1304 module depending on their location. In the lower area of the frame are  
shown the data and time that are received by the ЭМ-1242 interface unit from device  
"Гном-2МЭ". In case of signal absence in any of the channels for exchange with device  
"Гном-2МЭ" dashes are displayed instead of date and time.  
WINCH SS  
1R 1D STB  
1R 2D  
POD 108FR  
3R 3D  
4R 2D PCS  
DATE AND TIME FROM "ГНОМ –2МЭ" DEVICE  
CHANNEL 2 ЭМ-1242  
CHANNEL 1 ЭМ-1242  
N1  
30–01 –05 12:45:30  
30–01–05 12:45:39  
The number of the ACS frame No.2 is shown in the right lower corner.  
The ACS frame No.2, "STATE OF МТК-110МЭ TVDs" is shown in Fig.4.  
The left column, "N", shows the numbers (group-channel) of the TVDs. The group  
number is the number of the ТМ-1304 combined module. The channel number corresponds  
to the TVD connected to this ТМ-1304 combined module.  
Fig.3 –ACS Frame No.1 "STATE OF МТК-110МЭ".  
The "NAME" column contains the location of the TVD.  
The "CODE" column contains the code of the TVD.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
18  
17  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STATE OF
МТК
–110
МЭ
TVDs  
MODULE FEEDING VOLTAGES  
N2  
CODE  
ON  
CTRL  
1 DAY  
2 TEST  
---  
N
NAME  
PERISKOPE  
FE-6FR  
CHECK  
---  
---  
1
ЭМ-1213  
+6V1  
N1  
N3  
КТ-257  
1
1-1  
1-2  
1-3  
1-4  
2-1  
2-2  
2-3  
2-4  
3-1  
3-2  
3-3  
3-4  
4-1  
4-2  
4-3  
4-4  
5-1  
5-2  
5-3  
5-4  
ТМ–1220-1  
НЕОТОН-08-2  
НЕОТОН-08-1  
НЕОТОН-08-1  
ТМ–1220-1  
НЕОТОН-08-2  
НЕОТОН-08  
НЕОТОН-08-2  
ТМ–1220-1  
НЕОТОН-08-1  
НЕОТОН-08-1  
НЕОТОН-08-2  
НЕОТОН-08-2  
ТМ–1220-1  
НЕОТОН-08  
НЕОТОН-08-1  
НЕОТОН-08-1  
НЕОТОН-08  
ТМ–1220-1  
2 3  
+6V2  
----  
4
1R 1D STB  
1R 2D  
+6V3  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
-6V1  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
----  
---  
1R 1D PS  
SUPRSTR 20FR  
3R 1D  
+27V1  
+27V2  
---  
---  
ЭМ–1204-1  
---  
3R 3D  
+5V  
-5V  
---  
4R 1D  
---  
WINCH ACS  
4R 2D STB  
4R 2D PS  
5R PS  
ЭМ–1205-1  
---  
+5V  
---  
---  
ЭМ–1209-1  
+5V  
+5V  
---  
5R STB  
---  
WINCH SS  
4R 2D PCS  
6R 1D A  
6R 1D F  
TC  
ЭМ–1242  
---  
N3  
---  
---  
Fig. 5 – ACS Frame No.3 "MODULE FEEDING VOLTAGES".  
---  
---  
POD 108FR  
The feeding voltages are symbolically shown as horizontal lines with four marks. The  
leftmost mark represents the zero point. The next three marks represent the minimum,  
nominal and maximum values of the voltage. The length of a line denotes the voltage in a  
non-linear scale. The position of the minimum mark corresponds to 95% of the rated voltage.  
The position of the rightmost mark corresponds to 105% of the rated voltage. If the voltage  
controlled falls out of the tolerance limits, the line blinks that is a sign of a fault in the module.  
The output voltages of the three ЭМ-1213 power supply units are displayed in the upper part  
of the frame. The supply voltages produced by power supply cells in the corresponding  
modules are displayed below. The number of ACS frame No.3 is shown in the right lower  
corner.  
N2  
Fig.4 –ACS Frame No.2 "STATE OF МТК-110МЭ TVDs".  
The "ON" column contains the numbers of the CPs, from which the TVDs were  
switched on. If the same TVD was switched on from several CPs, their numbers are  
displayed via blanks. The device including the ЭМ-1212-1 control module and the ВС-2 TVM  
is designated as CP No.4 of the TV-complex. The "CTRL" column shows the number of a CP  
of the TV-complex and the remote control command being executed from this CP.  
The "CHECK" column shows the number of CP of the TV-complex from which the  
TVD was chosen for servicing.  
Frames are switched over by pressing the arrow buttons on the front panel of the  
ЭМ-1211 diagnostics module (Fig.2).  
The ЭМ-1212-1 control module indicates faulty modules of the TV-complex with the  
LEDs, in accordance with the information received from the ЭМ-1211 diagnostics module via  
the RCLI channel. Light-up of the LED of the МТК-110МЭ indicates a fault in some unit or  
module not represented on the ЭМ-1212-1 control module front panel. To get more specific  
information about the faulty module, the ACS frame No.1 should be output on the TVM  
screen.  
The number of ACS frame No.2 is shown in the right lower corner.  
The ACS frame No.3, "MODULE FEEDING VOLTAGES" is shown in Fig.5.  
P.  
P.  
20  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
19  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Light-up of one of the LEDs on the ТМ-1304 No.1 – ТМ-1304 No.5 combined modules  
on the ЭМ-1212-1 control module front panel means that either one of the modules  
comprised by the ТМ-1304 combined module is malfunctioning or the TVD working with this  
combined module is out of order. To localize the faulty module, the ACS frame No.1 should  
be output on the TWM screen.  
Light-up of the FUSE diode on the front panel of the ЭМ-1212-1 control module means  
that one of fuses F1-F16 installed on the fifth floor of the device is blown out. To localize the  
faulty fuse, the ACS frame No.1 should be output on the TVM screen.  
Information acquisition and control of the indication LEDs of the ЭМ-1212-1 control  
module is performed by the microcontroller and PLIC of the ACS. The ЭМ-1212-1 control  
module is installed in the middle of the second floor of the device. The device door has a  
glassy window opposite to the ЭМ-1212-1 control module thereby allowing observation on  
the state of the TV-complex when the door is closed.  
The three-phase feeding voltage 220 V, 50 Hz from the ЩР-03 switchboard is  
supplied to the device via a cable through connector XP1 and the assembly unit (A1). The  
device is switched on with toggle switch POWER. The three-phase voltage form the switch  
arrives to the indicator lamps through the three fuses and then - to PCB XT1 of the assembly  
unit. The switch and the fuses are found under the drop cover on the assembly unit front  
panel. The lamps indicating presence of feeding voltage 220 V,50 Hz are mounted on the  
assembly unit front panel.  
The three-phase feeding voltage 220 V, 50 Hz from assembly unit PCB XT1 through  
PCB XT1 of the device is supplied to the ФСП-3В interference rejection filters (A2 - A7) and  
then – to the ЭМ-1213 power supply units (A61, A71, A72). The ЭМ-1213 power supply units  
are connected to different phases of the three-phase mains.  
Each of the ЭМ-1213 power supply units has six galvanically decoupled d.c. outputs  
with the following parameters:  
- one 27 V output with a current of up to 4 A;  
- one 27 V output with a current of up to 2 A;  
- four 6 V outputs with a current of up to 2 A.  
1.1.4.5 Chronometrical Information Input System  
All the d.c. power supplies in the ЭМ-1213 power supply units have overcurrent and  
short-circuit protections that are automatically reset when the overload conditions are  
removed.  
The 6 V supply voltages produced by the ЭМ-1213 power supply units are used for  
feeding the modules of the device. The feeding voltage of plus 6 V is provided by connecting  
the negative terminals of the 6 V power supply units to the common bus, whereas for  
obtaining a feeding voltage of minus 6 V the plus 6 V power supply units are connected vice  
versa. The 6 V supply voltages are supplied to the device modules through PСB AP2 of the  
device.  
All the device modules that are supplied with the plus 6 V and minus 6 V voltages are  
fed from two or three ЭМ-1213 power supply units simultaneously. This ensures operability of  
the device in case of failure of one of the ЭМ-1213 power supply units.  
The modules consuming the plus 6 V and minus 6 V voltages contain power supply  
cells that form their own feeding voltages, provided at least one of the ЭМ-1213 power supply  
unit voltages is present. The internal supply voltages of the consuming modules are  
connected to the ЭМ-1211 diagnostics module inputs for control.  
The BC-2 TVM is fed from the ЭМ-1213 power supply unit (A72) with the plus 27 V  
voltage. The ЭМ-1239 power supply installed into the BC-2 TVM produces its own supply  
voltages of plus 12 V and plus 5 V.  
The chronometrical information input system receives chronometrical data via  
separate serial channels from device "Гном-2МЭ", transmits it to the external ТМ-1213  
terminal module for mixing into the video signal during video recording and displays this data  
on the screen of the ВС-2 TVM.  
The main unit of the chronometrical information input system is the ЭМ-1242 interface  
unit. The signals of the main and reserved channels of device "Гном-2МЭ" are supplied to  
the interface unit via connectors Х40 and Х41. The MC and PLIC of the ЭМ-1242 interface  
unit perform processing of these signals, reception of the incoming arrays containing  
chronometrical information and writing the data to the internal RAM of the PLIC.  
On request from the ЭМ-1209-1 controller the MC forms a reply array that is  
transferred to the ЭМ-1209-1 controller via a RCLI channel.  
The ЭМ-1209-1 controller periodically interrogates the ЭМ-1242 interface unit, forms  
data arrays containing date and time and transfers them to the ТМ-1213 terminal module  
and ЭМ-1211 diagnostics module. The latter displays the date and the time received  
from each of the "Гном-2МЭ" channels in ACS frame No.1. In case of absence of the  
information in one of the "Гном-2МЭ" channels, dashes are displayed in ACS frame  
No.1.  
The plus 27 V voltage from the other outputs of the ЭМ-1213 power supply unit is  
distributed among various units and modules of the TV-complex, passing through PCB AP1  
and fuses F1-F16 to the output connectors of the device. The fuses protect the power  
supplies against short-circuits in each of the loads. The fuses are installed on a panel on the  
fifth floor of the device. There is a LED near each of the fuses indicating presence of the plus  
27V voltage on the fuse output.  
1.1.4.6 Power Supply System  
The power supply system provides secondary feeding voltages for the units and  
modules incorporated by the device as well as some other units of the TV-complex.  
The power supply system comprises the following device modules:  
- assemble unit (A1);  
The external loads of the plus 27 V supply voltage of the ЭМ-1213 power supply units  
are shown in Table 3.  
- interference rejection filters, the ФСП-3В (A2 - A7);  
- power supply unit, the ЭМ-1213 (A61, A71, A72);  
- fuses F1 - F16;  
- power supply cells that are parts of the ЭМ-1204-1 and ЭМ-1205-1 videoswitch  
modules, ЭМ-1209-1 controller, ЭМ-1211 diagnostics module, ЭМ-1212-1 control module  
and ЭМ-1242 interface unit.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
22  
21  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
There is a connector X42 for connecting the auxiliary communication device (ACD).  
The auxiliary communication lines come in parallel to the TV-complex modules via  
connectors X32-X39. The +27 V feeding voltage is applied to an ACL via a current-limiting  
resistor for feeding the ACD.  
Table 3  
fuse  
number  
Device external  
connector  
External  
load  
+27V power supply unit  
The ТС-0120 ACD is included into the TV-complex BSP.  
ЭМ-1213 No.1 (А61)  
ЭМ-1213 No.3 (А72)  
ЭМ-1213 No.2 (А71)  
ЭМ-1213 No.3 (А72)  
ЭМ-1213 No.3 (А72)  
ЭМ-1213 No.1 (А61)  
ЭМ-1213 No.1 (А61)  
ЭМ-1213 No.2 (А71)  
ЭМ-1213 No.2 (А71)  
ЭМ-1213 No.3 (А72)  
ЭМ-1213 No.3 (А72)  
ЭМ-1213 No.1 (А61)  
F1  
F2  
Х32  
Х32  
Х33  
Х33  
Х34  
Х34  
Х35  
Х35  
Х36  
Х36  
Х37  
Х37  
ТМ-1304 No.1  
ТМ-1304 No.1  
ТМ-1304 No.2  
ТМ-1304 No.2  
ТМ-1304 No.4  
ТМ-1304 No.4  
ТМ-1304 No.5  
ТМ-1304 No.5  
ТМ-1304 No.3  
ТМ-1304 No.3  
Reserved  
1.1.4.8 Device Design  
F3  
F4  
As per design the device constitutes a splash-proof cabinet with an amortization base.  
The general view of the device is shown in Fig. B1 (appendix B). The floors of the cabinet are  
numbered top-down.  
F5  
The modules comprised by the device are located as follows.  
F6  
In the upper part of the cabinet the assembly unit (1) is installed. The feed switch and  
the fuses are mounted under the drop cover (23) to the left of the assembly unit front panel.  
The indicators (28) of phase voltage presence (220 V,50 Hz) are fastened on the front panel  
of the assembly unit.  
The ВС-2 TVM (2) is installed on the first floor. The TVM can be pulled out on a  
movable base.  
F7  
F8  
F9  
On the second floor are installed the ЭМ-1211 diagnostics module (3), ЭМ-1212-1  
control module (4) and ЭМ-1242 interface unit (5).  
F10  
F11  
F12  
On the third floor are installed (from left to right): the ЭМ-1204-1 videoswitch module  
(6), ЭМ-1205-1 videoswitch module (7), ЭМ-1204-1 videoswitch module of the BSP (8),  
ЭМ-1205-1 videoswitch module of the BSP (9), ЭМ-1211 diagnostics module of the BSP  
(10), ЭМ-1209-1 controller of the BSP (11), ЭМ-1209-1 controller of the BSP (12) and  
ЭМ-1209-1 controller (13).  
The fourth floor contains modules of the BSP such as the ЭМ-1211 diagnostics  
module (14), ЭМ-1212-1 control module (15) and ЭМ-1242 interface unit (17).  
On the fifth floor are installed the panel (17) with fuses F1-F16 and the LEDs.  
The ЭМ-1213 No.1 (18) power supply unit and ЭМ-1213 (19) of the BSP are installed  
on the sixth floor.  
Reserved  
ТМ-1213,  
ЭМ-1213 No.1 (А61)  
F13  
F14  
Х38  
ТМ-1215-4 No.1,  
ТМ-1215-4 No.2  
ТМ-1213,  
ТМ-1215-4 No.1,  
ТМ-1215-4 No.2  
ЭМ-1213 No.2 (А71)  
Х38  
ЭМ-1213 No.2 (А71)  
F15  
F16  
Х39  
ТМ-1215-4 No.3  
On the seventh floor are installed the ЭМ-1213 No.2 and ЭМ-1213 No.3 (18) power  
supply units.  
ЭМ-1213 No.3 (А72)  
Х39  
ТМ-1215-4 No.3  
The ФСП-3В interference rejection filters are mounted near the connectors of the  
ЭМ-1213 power supply units under the rear cover (21) of the cabinet. There are two ФСП-3В  
interference rejection filters per power supply unit.  
The ЭМ-1204-1 and ЭМ-1205-1 videoswitch modules, ЭМ-1209-1 controllers,  
ЭМ-1211 diagnostics modules, ЭМ-1212-1 control modules, ЭМ-1213 power supply units  
and ЭМ-1242 interface units constitute a frame with two horizontal slide rails. On the frames  
are mounted one or two PCBs with connectors. The front panel of the module is fastened to  
the frame. There are slide ways for each module in the cabinet. This modules are fixed in the  
working position with special locks and screws.  
The ТМ-1308 assembly modules and ТМ-1201 terminal modules via which the 27 V  
voltage passes in transit are not shown in Table 3.  
All the 27 V and 6 V d.c. voltages produced by the ЭМ-1213 power supply units are  
fed to the analog inputs of the ЭМ-1211 diagnostics module (A21). The ЭМ-1211 diagnostics  
module performs continuous tolerance check-up of these voltages. Also fed to the ЭМ-1211  
diagnostics module are the 27 V d.c. voltages from the outputs of fuses F1-F16 and voltages  
from internal power supply cells of the modules that are parts of the device.  
The ВС-2 TVM is fastened to a pull-out base that is mounted on telescopic holders.  
The ВС-2 TVM is fixed in the working position with four screws.  
1.1.4.7 Auxiliary Communication System  
The cabinet has a door with a rubber gasket, closing the modules from the second to  
the seventh floors. The door has four locks providing its fixing in the closed position. There  
are glassy windows opposite to the ЭМ-1212-1 control module (4). The ORDER OF UNITS  
(26) and a special wrench for module extraction/mounting (27) are fastened on the internal  
side of the door.  
The auxiliary communication system provides wire duplex communication between  
different modules of the TV-complex that is used during servicing of the complex.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
24  
23  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The bottom part of the cabinet is installed on an amortization base (25).  
In the upper part of the cabinet under the rear cover two resilient supports (24) for  
mounting the cabinet in a vertical position are installed.  
On the top of the assembly unit are installed the following elements: connector XP1 for  
connecting the mains voltage (220 V, 50 Hz), connectors Х32 - Х41 for interconnection  
cables, auxiliary communication connector X42 and connector X43 for an RS-232 channel.  
The latter is used during setup and servicing of the TV-complex.  
- ВС-2 TVM screen resolution – no less than 500 TV-lines;  
- viewing angle of ВС-2 TVM screen – from 100 to 140 deg. (horizontal), from 90 to  
120 deg. (vertical);  
- screen brightness (in white) for the whole visible area – from 250 to 350 cd/m2.  
- image contrast of ВС-2 TVM screen – 250:1.  
- image adjustment on the screen of ВС-2 TVM is done with five buttons on the TVM  
front panel via an on-screen menu.  
Coaxial connectors Х1 - Х31 are mounted on the rear cover of the cabinet.  
In the place of installation the cabinet on the amortization base is mounted on the  
foundation and fastened from the back to the corresponding mounting elements with the  
resilient supports. If the cabinet is transported through a hatch with a diameter of 594 mm the  
rear supports should be temporarily removed.  
1.2.1.1 Layout and Operation  
For studying the ВС-2 TVM electrical diagram ТЭ2.045.544Э3 should be used.  
The contents of the ВС-2 TVM is given in Table 4.  
Table 4  
The connector designation system, providing easy location of a connector basing on  
its number, is given in schematic connection diagram ТЭ3.623.912-03Э4.  
Cooling of the cabinet is done by natural ventilation. Cold air enters into the cabinet  
through the lower grating and leaves the cabinet through the upper grating.  
On the front of the lower part of the cabinet the "" (bonding point) terminal is located.  
This terminal must be coupled with the hull of the object of installation.  
Designation  
ТЭ2.049.458  
ТЭ2.201.833  
ТЭ3.057.444  
Code  
МО1-12  
Part Name  
Display module  
Qty.  
1
ЭМ-1239  
Power supply unit  
Video adapter  
1
ЭМ-1229  
1
The following signals are applied to the ВС-2 TVM:  
- feeding voltage, coming to connector X1;  
1.1.4.9 Measurement Instrumentation, Tools and Accessories  
- black-and-white video signal with a swing of (1,0 ± 0,3) V, coming to connector Х3.  
The ВС-2 TVM is switched on and off by pressing buttons ON and OFF on the front  
panel. On applying to the TVM a voltage of (27±3) V the "27 V" indicator lights up. As button  
ON is pressed, the LED near the button lights up and the TVM turns on.  
The ЭМ-1239 power supply unit feeding voltage to the ЭМ-1229 video adapter and  
МО1-12 display module.  
There are no special meters, tools and accessories required for work with the device.  
The control over the parameters of the device is performed with the means of automated  
control.  
To maintain the device a special wrench (Fig.B1, pos.27) and the tools of the toolkit  
included into the TV-complex BSP are used.  
The ЭМ-1239 power supply unit converts the primary d.c. voltage, 27V, into secondary  
stabilized d.c. voltages of 12 V and 5 V.  
1.1.4.10 Marking  
The ЭМ-1229 video adapter converts the black-and-white video signal with interlaced  
scanning into SVGA-standard signals with non-interlaced scanning and a frame frequency of  
60 Hz. These signals are input of the МО1-12 display module. At the same time, the video  
adapter generates sync pulses with horizontal and frame frequencies for synchronization of  
the display modules.  
The device is identified on the nameplate. The nameplate contains the device code, its  
industrial number and mass.The nameplate is fastened on the assembly unit.  
The MO1-12 display module is intended for displaying TV-image. The module  
constitutes a LCD-panel with backlighting lamps, a control circuit and an inverter for feeding  
the lamps. The LCD-panel with the control circuit and inverter is installed into a hermetic  
metal case and covered with a protective glass.  
As a voltage of 12 V is applied to the displaying module and the video signal is given  
to the VGA-input, the luminescent backlighting lamps switch on and an image of 800×600  
pixels with a refresh frequency of 60 Hz is formed on the screen.  
1.2 Description and Operation of Device Component Parts  
1.2.1 ВС-2 Television Monitor  
The ВС-2 TVM is intended for displaying black-and-white images with scanning  
parameters according to the broadcasting standard (interlaced scanning, 625 lines, 25  
frames per second).  
1.2.1.2 Instructions on Switching-On and Testing  
To switch on the BC-2 TVM press button ON and check if the indicator is lit.  
Select the source of the TV-signal on the ЭМ-1212-1 control module. Check the  
quality of the image and adjust brightness and contrast with the buttons on the TVM front  
panel (see item 1.2.1.3) if necessary.  
If there is no video signal, an image of chaotically lighting pixels is displayed on the  
TVM screen.  
The ВС-2 TVM is based on the МО1-12 flat-panel LCD-module.  
Technical parameters:  
- power supply of the ВС-2 TVM – from d.c. network, (27±3) V;  
- power consumption – 50 W, maximum;  
- dimensions of screen visible area – (246×185) mm;  
P.  
P.  
ТЭ3.623.912-03РЭ  
26  
ТЭ3.623.912-03РЭ  
25  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2.1.3 Intended Use of TVM  
Use this buttons to move the cursor to the needed item of the menu and activate the  
chosen item by pressing the MENU button.  
If the item chosen constitutes a group of settings (e.g. Quality), the submenu is  
displayed on the screen.  
To use the TVM, chose the video signal source on the ЭМ-1212-1 control module.  
In case of normal operation of the BC-2 TVM the image from the video signal source  
selected is displayed on the screen. The image should be sharp and have stable  
synchronization.  
If the item chosen is a parameter, (e.g. Contrast), adjustment of this parameter with  
Adjustment of the image parameters is done with the buttons on the front panel of the  
BC-2 TVM.  
The on-screen menu is called by pressing the MENU button. After that, the main menu  
in the English language appears on the screen:  
the and buttons is activated.  
Apart from the menu control buttons, there is an ON/OFF button allowing to switch  
on/off the screen backlighting and image displaying. The LED in the lower corner of the  
screen decorative frame should light yellow and green simultaneously when turning off and  
only green – when turning on.  
To switch the BC-2 TVM off press the OFF button on the TVM control panel. The ON  
LED should go out.  
Input Source  
PIP Enable  
Auto Tune  
Brightness  
Contrast  
Color  
Quality  
Position  
Language  
Recall  
Save Exit  
Cancel Exit  
Only the following items of this list are used during operation of TVM as a part of the  
TV-complex:  
Brightness;  
Contrast;  
Auto Tune – automatic quality adjustment and fitting the image into the screen;  
Position – placing the picture and menu window on the screen.  
On rare occasions additional quality adjustment is required:  
Quality – enhancing image sharpness and noise reduction.  
To finish work with MENU the following modes are used:  
Save Exit – save all the settings and leave the menu;  
Cancel Exit – cancel all the new settings and leave the menu;  
There is an additional key, AUTO, on the panel that is used for fast adjustment the  
BC-2 TVM for the video signal source.  
The on-screen menu is controlled with the following buttons on the panel:  
- allows to move the cursor frame upwards and increase the parameter chosen;  
- allows to move the cursor frame downwards and decrease the parameter chosen;  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
28  
27  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.2 External Examination of Device  
Check connection of external cables to the device.  
2.2.3 Initial Position of Controls before Use of Device  
Prior to the device switch-on the POWER toggle switch under the drop cover of the  
assembly unit should be in the off position. To open the drop cover unscrew the captive  
screws.  
2 OPERATION  
2.1 Operating Conditions and Safety Rules  
2.2.4 Interconnection wit other Devices  
The maximum permissible ratings of the device are shown in Table 4. Operation under  
stresses beyond these maximum limits is unsafe and can cause permanent damage to the  
device.  
Table 4  
The device is used together with device "Гном-2МЭ" that is not a part of the TV-  
complex.  
The device receives chronometrical information from "Гном-2МЭ" device via a line  
with transformer decoupling. No reply information is transmitted to the "Гном-2МЭ" device.  
The device state does not influence on operation of "Гном-2МЭ".  
The device is the central module of the TV-complex and interacts directly or non-  
directly with all the modules of the TV-complex.  
Technical Parameter  
Maximum Limit  
Note  
231 V, continuous  
249 V, transient, up to 3 s  
Primary side supply voltage  
2.1.1 The device should be operated only by qualified personnel acquainted with this  
OM, electric connection diagram ТЭ3.623.912-03Э4 and knowing the operating principle of  
the device.  
2.2.5 Switching-On and Testing of Device  
2.1.2 The device is fed with a dangerous for life voltage of 220 V. Therefore the  
following safety rules must be observed:  
2.2.5.1 Make sure that the POWER switch on the ЩР-03 switchboard and also the  
МТК-110МЭ, PANELS and PERISCOPE switches are turned on. The indicators of phase  
voltage presence should light, phase voltages should be from 180 to 231 V.  
2.2.5.2 Open the drop cover of the assembly unit.  
Open the door of the device by rotating counter-clockwise the clamping nuts of the  
locks and putting the handles of the locks into the "UNLK" position.  
2.2.5.3 Switch on the POWER toggle switch under the drop cover of the assembly  
unit. The following indicators should light up:  
- do not use the device without reliable grounding;  
- do not use the device with its side or rear covers removed;  
- do not use self-made fuses or those with ratings different from the recommended;  
- never replace fuses or modules, connect or disconnect any cables when the device  
is on.  
2.1.3. No mechanical works should be done while the device is switched on.  
- presence of phase voltages, "P1", "P2", "P3"; this indicators are mounted on the front  
panel of the assembly unit;  
2.2 Device Preparation for Operation  
- "27V" on the front panel of the ВС-2 TVM;  
- 16 indicators on the fuse panel of the fifth floor of the device;  
- two indicators on еach of the front panels of the three ЭМ-1213 power supply units.  
2.2.5.4 Turn on the ВС-2 TVM by pressing the ON button. After this the indicator near  
the ON button should light up.  
2.2.1 Safety Precautions during Installation  
Adjust brightness and contrast with the buttons on the TVM front panel as described in  
item 1.2.1.3. of the present OM if necessary.  
2.2.5.5 Press the button TEST ЭМ-1212-1 on the ЭМ-1212-1 control module. After  
that:  
- by turns, from top to bottom and from left to right, the red LEDs under the TROUBLE  
inscription will light up and then go out;  
When preparing the device for operation make sure that:  
- bonding point "" is connected to the hull of the object;  
- all the modules are installed and fastened in their dedicated positions;  
- all the fuses are installed and fixed in the holders.  
During operation, bright rays of light from external sources of light should not fall onto  
the screen of the BC-2 TVM.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
30  
29  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- by turns, from top to bottom and from left to right, the green LEDs installed near the  
buttons will light up and then go out;  
2.3.3 Possible Troubles and Remedies thereof  
Such lighting-up of all the LEDs means that the LEDs indicating the state of the TV-  
complex are serviceable.  
After completion of testing lighting-up of the LEDs, no LED under the TROUBLE  
inscription should be lit.  
Repair of the device is performed by replacing the faulty modules with serviceable  
ones included into the BSP and DSP.  
For detection of faults in the device the ACS should be used.  
Lighting of a red LED of the TROUBLE group on the ЭМ-1212-1 control module front  
panel near the code of a module or a group of modules testifies to malfunction of those.  
For more exact location of the faulty module, unit or fuse switch on the BC-2 TVM and  
press the ENTER button on the front panel of the ЭМ-1211 diagnostics module. ACS frame  
No.1, "STATE OF МТК-110МЭ", will appear on the screen of the BC-2 TVM. The codes of  
faulty modules, units and fuses of the device will be blinking. Replace these modules, units  
and fuses with good ones from the BSP or DSP.  
The ACS permits to find the most probable troubles in the device.  
For detection of less probable troubles follow the recommendations given in items  
2.3.3.1 - 2.3.3.11.  
2.3.3.1 After pressing the TEST button on the ЭМ-1212-1 control module one or  
several LEDs do not light up.  
Cause – the ЭМ-1212-1 control module is out of repair.  
Remedy – replace the ЭМ-1212-1 control module with the serviceable one from the  
BSP.  
2.2.5.6 Press the ENTER button on the ЭМ-1211 diagnostics module. Frame No.1 of  
the ACS, "STATE OF МТК-110МЭ", should appear on the BC-2 TVM screen. All the  
modules, units and fuses in this frame should be in on-state and should not blink.  
Press the "" button on the ЭМ-1211 diagnostics module. Frame No.3 of the ACS,  
"MODULE FEEDING VOLTAGES", should appear on the BC-2 TVM screen. The horizontal  
lines showing the values of the supply voltages should be between the marks corresponding  
to the minimum and maximum values.  
Press the SELECT button on the ЭМ-1211 diagnostics module. The ACS frame will  
disappear from the screen of the BC-2 TVM and the screen will display the VS from the TVD  
activated from the ЭМ-1212-1 control module.  
2.2.5.7 Check operation of the TVDs and viewing the signals from those. This is done  
by pressing the GROUP1 button and then – the CHANNEL1-CHANNEL4 buttons. The  
screen of the TVM should display the image from the TVD corresponding to the selected  
channel and group. Then repeat the same for groups 2 – 5 for all the channels of these  
groups and make sure that image from each of the TVDs is present. Press the OFF button to  
switch the TVDs off.  
2.2.5.8 Close the cover of the assembly unit. Close the door of the device by putting  
the lock handles into the "LK" position and tighten the clamping nuts by rotating them  
clockwise.  
2.3.3.2 Several TVDs of the same group or of the same channel in several groups can  
not be switched on from the ЭМ-1212-1 control module. The corresponding LED near the  
button does not light up.  
Cause – the button or the PLIC of the ЭМ-1212-1 control module are out of order.  
Remedy – replace the ЭМ-1212-1 control module with the serviceable one from the  
BSP.  
2.3.3.3 One group or one channel of the ЭМ-1212-1 control module does not switch  
off by pressing the OFF button. In this case, the LED near this button goes out only when the  
button is pressed and lights up again if the button is released.  
2.3 Usage of Device  
Cause – the button or the PLIC of the ЭМ-1212-1 control module are out of order.  
Remedy – replace the ЭМ-1212-1 control module with the serviceable one from the  
BSP.  
2.3.1 Personnel Operation during Intended Use of Device  
2.3.3.4 When the ON button of the BC-2 TVM is pressed the LED near the ON button  
does not light and the BC-2 TVM does not work. At the same time the "27V" LED lights.  
Case – fault in the ЭМ-1239 power supply unit that is a part of the BC-2 TVM.  
Remedy – replace the ЭМ-1239 power supply unit with the serviceable one from the  
BSP.  
After enabling and testing the device does not require any servicing by special  
personnel.  
The device begins to execute its main functions in 1 s. after switching on the POWER  
toggle switch on the assembly unit regardless of operations during testing the device.  
2.3.3.5 There is no image synchronization on the screen of the BC-2 TVM.  
Cause – fault in the ЭМ-1229 video adapter that is a part of the BC-2 TVM.  
Remedy – replace the ЭМ-1229 video adapter with the serviceable one from the BSP.  
2.3.2 Checking Operability of Device  
2.3.3.6 There is no image on the screen of the BC-2 TVM when signals from a TVD or  
from the ЭМ-1211 diagnostics module are commutated to the TVM screen. The image does  
not appear even after pressing the RESTART button on the ЭМ-1211 diagnostics module.  
Cause No.1 – fault in the ЭМ-1211 diagnostics module as per signal commutation.  
Remedy – replace the ЭМ-1211 diagnostics module with the serviceable one from the  
BSP.  
The operability control is done in compliance with items 2.2.5.2 - 2.2.5.8. If the toggle  
switch on the assembly unit is on do not switch it again.  
Cause No.2 fault in the ЭМ-1229 video adapter that is a part of the BC-2 TVM.  
Remedy – replace the ЭМ-1229 video adapter with the serviceable one from the BSP.  
Cause No.3 – the BC-2 TVM is out of repair.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
32  
31  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remedy – replace the BC-2 TVM with the serviceable one from the BSP.  
2.3.4 Switching the Device off  
2.3.3.7 No image from several TVDs on the TVM screens of all the CPs. The ACS  
indicates that the TVDs and the ЭМ-1204-1 VS commutation module are fault-free.  
Cause – the VS matrix switch in the ЭМ-1204-1 VS commutation module is out of  
order.  
Remedy – replace the ЭМ-1204-1 VS commutation module with the serviceable one  
from the BSP.  
To switch the device off press the OFF button on the BC-2 TVM.  
Move the toggle POWER switch on the assembly into the off position. Make sure that  
the phase voltage indicators do not light.  
Close the drop cover on the assembly device. Close the door of the cabinet.  
2.3.3.8 No image from the КТ-257 TV-camera on the TVM screens of several CPs.  
The ACS indicates the KT-257 TV-camera and the ЭМ-1205-1 VS commuatation module are  
fault-free.  
Cause - the ЭМ-1205-1 VS commutation module is out of order.  
Remedy – replace the ЭМ-1205-1 VS commutation module with the serviceable one  
from the BSP.  
2.3.3.9 According to the ACS, one of the 27 V output voltages in one of the ЭМ-1213  
power supply units is missing. The “27 V” LED on the front panel of the ЭМ-1213 power  
supply does not light. After replacing the ЭМ-1213 power supply unit with the serviceable one  
from the BSP the trouble persists.  
2.3.5 Safety Precautions during Usage of Device  
The device is fed with a voltage of 220 V that is dangerous for life.  
Never replace fuses, remove the included modules or unlink the connectors of  
external cables when the device is energized.  
If a faulty module is detected, it should be replaced only after switching-off the power  
supply of the device by moving the POWER toggle switch into the off position.  
Prior to replacement of the ФСП-3В filter, the POWER switch of the device and all the  
switches on the ЩР-03 switchboard must be moved in the off position.  
Cause – one of the six ФСП-3В filters is out of order.  
Remedy – using the ACS determine exactly the faulty ФСП-3В filter by missing +27V  
voltage as follows:  
- no "+27 ВI" from the output of the ЭМ-1213 No.1 (A61) – fault in А2 (designations of  
the ФСП-3В filters is shown in diagram ТЭ3.623.912-03 Э4);  
- no "+27 VII" from the ЭМ-1213 No.1 (A61) - fault in А3;  
2.4 Measures under Emergency Conditions  
- no "+27 VI" from the ЭМ-1213 2 (A71) - fault in А4;  
- no "+27 VII" from the ЭМ-1213 2 (A71) - fault in А5;  
- no "+27 VI" from the ЭМ-1213 3 (A72) - fault in А6;  
- no "+27 VII" from the ЭМ-1213 3 (A72) - fault in А7.  
Under emergency conditions in the place of device installation, e.g. appearance of  
smoke, fire, a danger of flood, de-energize the device by moving the POWER toggle on the  
ЩР-03 switchboard in the off position.  
If an emergency situation arises in the place of installation of the ТМ-1304 combined  
modules, TVDs or ТМ-1215-4 control modules of the TV-complex, the conditions there  
should be observed on as long as possible.  
Under the danger of failure or in case of some TV-complex equipment failure de-  
energize the corresponding units and modules.  
The feeding voltage can be switched off by removing the fuses on the fuse panel of  
the fifth floor of the device. In case of module or unit failure under emergency conditions the  
following fuses must be removed:  
- in case of the ТМ-1304 No.1 combined module failure - F1, F2;  
- in case of the ТМ-1304 No.2 combined module failure - F3, F4;  
- in case of the ТМ-1304 No.3 combined module failure - F9, F10;  
- in case of the ТМ-1304 No.4 combined module failure - F5, F6;  
- in case of the ТМ-1304 No.5 combined module failure - F7, F8;  
- in case of failure of the ТМ-1213 terminal module, ДЕ-118-1 VRD, ТМ-1215-4 No.1  
and ТМ-1215-4 No.2 control modules - F13, F14;  
- in case of the ТМ-1215-4 No.3 control module failure - F15, F16.  
The said fuses can blow-out by themselves. In this case, do not replace them until the  
effects of the emergency situation are not removed.  
Replace the faulty filter with the serviceable one of the DSP.  
2.3.3.10 The ACS indicates a fault in some module or unit of the device because the  
feeding voltage of this module or unit exceeds the tolerance bounds. Even so, the faulty  
module or unit continues to operate normally. After replacing the faulty module with the  
serviceable one from the BSP, the ACS indicates the same fault.  
Cause – the ЭМ-1211 diagnostic module is out of repair.  
Remedy – replace the ЭМ-1211 diagnostics module with the serviceable one from the  
BSP.  
2.3.3.11 No chronometrical information from both the channels of the "Гном-2МЭ"  
device. The latter operates normally. The ACS indicates that the ЭМ-1242 interface unit is  
fault-free.  
Cause - the ЭМ-1242 interface unit failure as per the interface with device  
"Гном-2МЭ".  
Remedy - replace the ЭМ-1242 interface unit with the serviceable one from the BSP.  
2.3.3.12 After replacing a faulty module with a serviceable one, make a record in TV-  
complex logbook ТЭ1.133.110-02ФО.  
In case of emergency evacuation of the operating personnel switch the device off by  
moving the POWER toggle on the ЩР-03 switchboard in the off position.  
P.  
P.  
34  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
33  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- visual inspection of the device and front panels of its modules behind the door of the  
cabinet, cleaning the outside of dirt, dust and moisture;  
- check on paint and electroplate coatings;  
- check on the conditions in the place of installation and operation, with making a  
decision on possibility of using the device under such conditions.  
3.1.3.2 Examination No.2  
Examination No.2 includes Examination No.1 in full and besides the operability check-  
up in accordance with items 2.2.5.2 - 2.2.5.8 of the present Manual.  
3.1.3.3 Maintenance.  
Maintenance involves removal of the electronic modules from the installation places  
and includes Examinations No.1 and No.2 in full and also some additional measures:  
- cleaning of the device inside of dust with a vacuum cleaner using a soft brush;  
- check on the condition of printed circuit tracks in the electronic modules;  
- check on the condition of connector contacts;  
3 MAINTENANCE  
3.1 Servicing of Device  
- check on whether the plastic details have flaws or dents.  
3.1.3.4 Examination No.1 should be done daily, the device being in the off-state.  
Examination No.2 should be done weekly.  
3.1.1 General Guidelines  
Maintenance should be carried out once in half a year or if necessary. If a faulty  
module is detected, it should be replaced with a serviceable one from the DSP or BSP. While  
replacing, the POWER toggle switch on the assembly unit must be in the off position.  
Servicing of the device is performed for maintaining operability of the device within the  
whole service life.  
Servicing envisages carrying out examinations No.1 and No.2 and maintenance of the  
device as well as their execution order and contents when the object on which the TV-  
complex is installed stays at the depot.  
Maintenance should not be carried out in case of intended use of the device.  
Maintenance should be performed by two qualified specialists having radio  
engineering education with TV and computer techniques specialization. At least one of the  
specialists must have a higher education.  
3.1.4 Replacement of Modules in Device  
When replacing the TVM, modules and units of the device use the wrench fastened on  
the inside face of the door and the tools of the toolkit from the TV-complex BSP (box 2/8).  
3.1.4.1 Replacement of ЭМ-1204-1 and ЭМ-1205-1 videoswitch modules, ЭМ-1209-1  
controller, ЭМ-1211 diagnostics module, ЭМ-1213 power supply units and ЭМ-1242 interface  
unit.  
3.1.2 Safety Measures  
Modules and units are removed from the device in the following order:  
- unscrew the two captive screws fixing the module (unit) front panel in the device;  
- put the special wrench into the slot of the module (unit) lock and turn the wrench by  
180º counter clockwise, the module (unit) should move out by approximately 10 mm;  
- remove the module (unit) from its place by careful pulling it out.  
Installation of a serviceable module (unit) of the BSP into the device is done as  
follows:  
- set the horizontal slide rails of the module (units) into the slots in the device;  
- push in the module (unit) up to the stop, about 10 cm off the final position;  
- put the wrench into the slot of the module (unit) lock and slightly pushing the module  
(unit) in turn the wrench clockwise by 180º. The module (unit) should move into the working  
position;  
A life-hazardous voltage of 220 V, 50 Hz is used in the device.  
Only personnel allowed for work with voltages of up to 1000 V should maintain the  
device.  
When servicing all operations that are not associated with the device parameters  
check-up during examination No.2 are done on the de-energized device.  
Never replace fuses, remove the included modules or unlink the connectors of  
external cables when the device is energized.  
3.1.3 Maintenance Execution Order  
- put on the captive screws on the module (unit) front panel.  
3.1.4.2 Replacement of the ЭМ-1212-1 control module is done as follows:  
- unscrew the three captive screws fixing the module (unit) front panel in the device;  
- by turns put the wrench into the slots of the left and the right locks of the module and  
turn it counter clockwise by 30-60º each time. Acting as described above, move the module  
out by approximately 10 mm;  
3.1.3.1 Examination No.1.  
Examination No.1 includes the following actions done without removing the modules  
and units from the device:  
P.  
P.  
36  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
35  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- remove the module from its place by careful pulling it out.  
Installation of the serviceable module from the BSP into the device is done as follows:  
- set the horizontal central slide rails of the module into the slots in the device;  
- push in the module up to the stop, about 10 cm off the final position;  
- by turns put the wrench into the slots of the left and the right locks of the module and  
turn it clockwise by 30-60º each time. Acting as described above, move the module into the  
working position;  
3.1.5 Device Operability Check-Up  
Testing the device while maintaining it is to be done in accordance with item 2.2.5 of  
the present Manual.  
- put on the captive screws on the module (unit) front panel.  
3.1.4.3 Replacement of the ФСП-3В interference rejection filter (hereinafter referred to  
as “filter”) is done as follows:  
- undo the screws fastening the cover in the lower part of the device rear wall;  
- remove the cover and put it aside;  
- take the soldering iron out of the toolkit; connect it to the plug-transformer for 24V;  
- unsolder the wires off the contacts of the filter, mark them and move them aside;  
- undo the screws fastening the ФСП-3В in the device;  
- take out the ФСП-3В;  
- install the serviceable ФСП-3В from the DSP in the place of the faulty one;  
- fix the ФСП-3В with the screws;  
- solder the wires to the contacts of the ФСП-3В;  
- switch the soldering iron off;  
- install the cover and fix it with the screws.  
3.1.4.4 Replacement of the ВС-2 TVM is done as follows:  
- undo the four captive screws in the corners of the ВС-2 TVM front panel;  
- pull the handles and move the ВС-2 TVM out of the device up to the stop on the  
telescopic holders;  
- remove the cable connectors linking the ВС-2 TVM with the device;  
- undo the screws fastening the ВС-2 TVM to the movable base;  
- take the ВС-2 TVM out of the device;  
- mount the serviceable ВС-2 TVM from the BSP on the movable base of the device;  
- fasten the ВС-2 TVM on the movable base with the screws;  
- fix in the cable connectors linking the ВС-2 TVM with the device;  
- push in the ВС-2 TVM into the device until it stops in the working position;  
- put on the captive screws on in the corners of the BC-2 TVM front panel.  
3.1.4.4.1 Replacement of the ЭМ-1229 video adapter and ЭМ-1239 power supply unit  
in the ВС-2 TVM is done as follows:  
- remove the ВС-2 TVM out of the device (see item 3.1.4.4);  
- put the ВС-2 TVM on a smooth and plane surface with its face side down;  
- undo the screws on the rear wall of the ВС-2 TVM;  
- open the rear wall of the ВС-2 by an angle exceeding 90 deg.;  
- undo the four screws, fastening the faulty unit to the two laths on the rear wall;  
- unplug the unit off the connector;  
- install the serviceable unit from the BSP instead of the faulty one and fasten it with  
the screws;  
- install the rear wall and fasten it with the screws;  
- install the TVM into the device (see item 3.1.4.4).  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
38  
37  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX А  
(obligatory)  
List of Abbreviations and Special Terms Used in this Manual  
ACD  
ACL  
ACS  
ADC  
BSP  
CP  
auxiliary communication device;  
auxiliary communication line;  
automated checkout system;  
– analog-to-digital converter;  
onboard spare parts;  
– control panel;  
CS  
control system;  
DAC  
DGP  
DSP  
LC  
digital-to-analog converter;  
device genlocking pulse;  
depot spare parts;  
– liquid crystal;  
LED  
- light-emitting diode;  
MC  
microcontroller;  
МP  
microprocessor;  
OM  
operating manual;  
PLIC  
RAM  
RCLI  
RCB  
RGP  
ROM  
programmable logic integrated circuit;  
random access memory;  
– radial corrent loop interface;  
- printed circuit board;  
receiver genlocking pulse;  
read only memory;  
RS-232 standard serial interface;  
TVD  
– television device, this term generalizes names of following devices:  
Неотон-08, Неотон-08-1, Неотон-08-2, КТ-257, ТМ-1220-1;  
TVM  
VRD  
VS  
– television module;  
– video recording device;  
– video signal.  
P.  
P.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
40  
39  
Rev.  
P.  
Dokument N Signature Data  
Rev.  
P.  
Dokument N Signature Data  
Size А3 /А4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Лист регистрации изменений  
Лист регистрации изменений  
Номера листов (страниц)  
Номера листов (страниц)  
Входящий  
номер  
сопроводи–  
тельного Подп. Дата  
Входящий  
номер  
сопроводи–  
тельного Подп. Дата  
Всего  
листов  
(стра–  
ниц)  
в
Всего  
листов  
(стра–  
ниц)  
в
Номер  
документа  
Номер  
документа  
Изм.  
Изм.  
изменен–  
заменен–  
новых  
ных  
аннули–  
рованных  
изменен–  
заменен–  
новых  
ных  
аннули–  
рованных  
документа  
документа  
ных  
ных  
и
дата  
и
дата  
докум.  
докум.  
С.  
С.  
ТЭ3.623.912-03РЭ  
ТЭ3.623.912-03РЭ  
Изм.  
С.  
№ документа Подпись Дата  
Изм.  
С.  
№ документа Подпись Дата  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Radio WS 7090U User Manual
Lasko Fan 4890 User Manual
Lexmark Printer Z13 Z23 Z33 User Manual
LG Electronics Microwave Oven MJ3281BCG User Manual
Linksys Network Card PCMPC100 User Manual
Lux Products Thermostat TX9000A User Manual
Mackie Stereo Amplifier UP4061 User Manual
Makita Saw 5007NB MCP User Manual
Maytag Water Heater HRN11240P User Manual
Melissa Vacuum Cleaner 640 056 User Manual