Introduction  
Power Requirements  
The Meyer HM-1S Studio Monitor is a compact, full-  
range, self-powered reference monitor that employs a  
concentric tweeter mounting structure to achieve true  
point-source performance. Sophisticated phase-correc-  
tion circuitry provides superb imaging without the off-axis  
cancellation effects, back-wave interference, and IM dis-  
tortion commonly exhibited by dual-concentric speakers.  
The HM-1S requires a 48 VDC external power supply,  
which provides these benefits:  
Low voltage wiring simplifies installation.  
Utilizes telecom 48 V supply and bus standard.  
Eliminates 50/60 Hz AC noise coupling in wiring.  
The power supply input uses a male 2-pin EN3 connector.  
The HM-1S can be powered by the Meyer PS-1 AC  
adapter or a supply that conforms to the 48 VDC specifi-  
cations detailed in this section.  
The HM-1S Studio Monitor is a two-way system comprising a  
7-inch graphite cone low-frequency driver, and a concen-  
trically-mounted, 1-inch soft-dome high-frequencydriver.  
A constant-directivity, high-frequency horn affords a sym-  
metric 100° beam width. The HM-1S employs optimized  
electronics, drivers, and cabinet venting (tuned to40Hz)  
to achieve low frequency response far exceeding that of  
mostsmallspeakers.Thedriversaremagneticallyshielded  
and the magnets employ field-cancelling techniques  
to minimize magnetic leakage, allowing speaker place-  
ment within one foot of color video monitors.  
MeyerPS-1ACAdapter  
Using the Meyer PS-1AC adapter is the simplest way to  
power a pair of HM-1Ss, or a single HM-1S with a sub-  
woofer. TheAC adapter can be purchased through Meyer  
Sound and comes with two 10 ft power cables. The AC  
adapter has two output connectors that are wired together  
inside the supply, allowing either one connector to  
drive two speakers at the end of a single cable, or one  
connector and cable per speaker.  
The HM-1S can be used with the Meyer HM-1S Studio  
Subwoofer, extending the free-field LF (low frequency)  
response down to 42 Hz. The passive subwoofer is  
poweredfromtheSuboutputontherearpaneloftheHM-  
1S. Although each HM-1S Studio Monitor can power a  
subwoofer, ample LF energy may be obtained by driving  
one subwoofer from two HM-1S Studio Monitors, result-  
inginacorrectly-summedmonosignal. Subwooferusage  
depends on the loading conditions, the LF gain desired,  
and whether a stereo LF signal is required. Placing the  
HM-1S next to a wall or ceiling (half-space loading) also  
extends the LF response down to 42 Hz.  
Do not connect the outputs of multiple PS-1 AC  
adapters together!  
For installations up to 10 HM-1Ss, using multiple PS-1  
AC adapters is often the simplest and most cost-effective  
solution. Since the limited output power for each supply  
acts as circuit protection for light gauge cables, it is not  
necessary to install circuit breaker distribution panels.  
Using the PS-1 does, however, limit each 48 V line to two  
speakers. The dimensions of theAC adapter are 10” x 5” x 3”.  
Contact Meyer Sound for further information on the PS-  
1 AC Adapter.  
The HM-1S Studio Monitor and Subwoofer cabinets are  
constructed from medium density fiberboard and fin-  
ished with an attractive, durable oak veneer (natural  
wood or black). Although external heatsinks on the rear  
of the cabinet provide adequate convection cooling, a  
variable-speedcoolingfanassembly(part#40.039.016.01,  
driven from a rear-panel output and mounted on the rear  
of the speaker) is available if the HM-1S will be operated  
in hot temperatures or in an unventilated, enclosed area.  
Theenclosurecontainsa400Wstereoamplifier, anactive  
crossover, frequency and phase alignment circuitry, and  
driver protection voltage limiters. Front-panel LEDs indicate  
power, signal limit, and thermal overload, and a rear-  
panel circuit breaker provides overall DC power protection.  
!
Do not use a ground-lifting adapter or cut the AC  
cable ground pin.  
The HM-1S accepts a unipolar 48 VDC power source,  
which may be supplied by the Meyer PS-1 AC Adapter.  
Using a DC supply enables long power cable runs with  
minimal induced noise or hum, which is particularly im-  
portant for recording studios and other noise sensitive  
environments.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supplies for Larger Systems  
If an installation includes more than 10 speakers, or  
requires several speakers to operate from a single 48 V  
line, a single, high-output power supply should be  
considered. The following sections provide current and  
voltagespecificationsfortheHM-1S’spowerrequirements.  
Current Ratings  
Thewidedynamicrangeofaudiosignalsnormallycauses  
a high peak-to-RMS ratio in an amplifier’s DC supply  
currents. The HM-1S has internal storage circuits to  
minimize the peak-to-average ratio, which  
reduces the peak power rating required by the  
supply;  
allows efficient use of switched-mode power sup- An HM-1S with subwoofer draws 0.4 ADC, 20 W in a  
plies which have similar peak and continuous rat- quiescent state.  
ings.  
Voltage Ratings  
The following table lists the current and power draw for a  
single HM-1S at light, moderate, and maximum operating  
levels.  
The voltage operating range for the HM-1S is 48 VDC  
nominal, 52 VDC absolute maximum, and 35 VDC  
minimum without shutoff.  
Allowing operation down to 35 VDC provides two ben-  
efits. First, a moderate voltage drop (up to 8 V) for long  
DC power cables has a minimal impact on audio perfor-  
mance, enabling the use of light-gauge cables for most  
installations.  
Second, since some switched-mode power supplies  
slowly foldback the voltage if they experience current-  
limit, power supplies with lower power (current) ratings  
can be used efficiently. Since supplies with lower power  
ratings typically experience current-limit when the HM-  
1S is at continuous limiting, some voltage drop and loss  
of headroom is acceptable provided the voltage does  
not drop below 35 VDC. At 35 V, the maximum current  
draw is 25% lower than the values stated in the preceding  
tables.  
Each HM-1S draws 0.4 ADC, 20 W in a quiescent state.  
The RMS current is measured over a 500 ms integration  
time. The peak current is measured over a 10 ms integration  
time.  
Each HM-1S can drive a slaved Meyer subwoofer from a  
connection on the amplifier panel. Adding the subwoofer  
increases the amplifier’s output current, which increases  
the power supply current. The current and power ratings  
for an HM-1S and a subwoofer are listed in the following  
table at light, moderate, and maximum operating levels.  
NOTE: If the HM-1S will not be driven at continuous limiting,  
a power supply that satisfies the moderate specifications  
for voltage and current can be used safely without risk of  
sonic degradation or interruption.  
It is important to understand how the selected power  
supply responds to current-limit, particularly for switched-  
mode supplies. Some supplies trip off and must be reset  
manually, while others remain off for a period of time and  
reset automatically. In both cases, the HM-1S suffers  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
audio interruption. In the third, and preferable case, Asingle HM-1S attached to a 100 ft 18AWG cable (1.27  
supplies that feature voltage foldback allow brief periods total) produces a 6.4 VDC loss at the speaker (41.6 V)  
of current-limit without audio interruption; for this reason, during maximum audio bursts (5A, 0.5 s). This results in  
we recommend using such supplies.  
a small loss in peak SPL.  
The HM-1S does not require tight voltage regulation and  
operates down to 35 V although peak SPL values are  
reduced. This operating voltage flexibility allows for wir-  
ing loss and voltage foldback without interruption or  
degradation of the audio signal.  
Audio Input  
TheHM-1Shasaninputimpedanceof10kandreceives  
its audio input signal at a female XLR connector. Pins 2  
and 3 carry the input as a differential signal; pin 1 and the  
case are connected to the chassis. The power and audio  
cables can be jacketed in the same sheath without induc-  
ing noise to the input signal.  
Many high power industrial supplies (1–5 kWatt) are  
available for 19” EIA racks that are suitable for large  
installations with equipment rooms. Distribution panels  
with branch circuits can be used economically with up to  
8 HM-1Ss on a branch. Contact Meyer Sound for in-  
formation on tested and approved supplies.  
For best EMI immunity, it is desirable to use a twisted pair  
shielded cable with the twisted pair connected to pins 2  
and 3, and the shield to pin 1. However, an unshielded  
twisted pair cable can be used effectively, even if it is  
jacketed with the power cable.  
Power Cable Requirements  
Each HM-1S draws a maximum of 3 Arms and 5 Apk The input is RF and ESD protected, capacitive coupled,  
from a 48 V power supply at peak SPL. The cabling ±50Vcommon modetoground, +4dBunominal, +21dBu  
between the 48 V supply and the speaker adds resis- max. Clippingoccursattheinputat12Vpk. TheCommon  
tance to the circuit and produces a voltage drop at the Mode Rejection Ratio (CMRR) is greater than 80 dB.  
speaker. Decreasing the voltage at the speaker com-  
promises the peak SPL so cable resistance should be  
minimized.  
The HM-1S Subwoofer  
For best sonic performance, avoid voltage drops greater  
than 8 V at the speaker. Voltage drops greater than 15  
V may cause the speaker to mute or distort. The maxi-  
ThelowfrequencyresponseofanHM-1Scanbeextended  
mum round-trip resistance for a cable attached to a  
downto42HzifusedwiththeHM-1SSubwooferorplaced  
single HM-1S should be no higher than 1.6 , which  
keeps the voltage drop below 8 V during the maximum  
current draw of 5 Apk.  
next to a wall or ceiling (half-space loading). Each HM-1S  
can power a subwoofer from the male 3-pin EN3 Sub  
outputconnectorontherearpanel.However,dependingon  
the loading conditions, ample low frequency energy may  
be obtained by driving a single subwoofer from two HM-  
1Ss, resultinginacorrectly-summedmonosignal. Cables  
forconnectingoneHM-1Stoasubwoofer andtwoHM-1s  
to a single subwoofer are shipped with each HM-1S  
Subwoofer.  
The following table helps select cable gauges for various  
cable lengths.  
The addition of one subwoofer increases the maximum  
SPLof a single HM-1S by 4 dB (without sub: 116 dB SPL;  
with sub: 120 dB SPL). The HM-1S Subwoofer has the  
following specifications:  
Transducer  
10” low frequency cone driver  
Enclosure/Finish  
Medium Density Fiberboard (MDF) /  
Oak Veneer (natural or black)  
Weight  
33 lb (11.0 kg)  
Dimensions  
Height: 17.5”; Width: 12.3”; Depth: 9.3  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S Speaker Cable  
The following drawings and procedures are provided as  
an aid in the event that the speaker cable used to connect  
theHM-1StotheHM-1SSubwooferneeds toberepaired  
or extended. In cases where the original speaker cable  
has been modified, be sure to complete the Subwoofer  
Performance Verification section on page 10 of this  
manual. Misalignment of the polarity between the HM-1S  
and the HM-1S Subwoofer will result in a serious degra-  
dation of performance.  
(Single HM-1S to HM-1S) Stereo Subwoofer Cable  
M.S.P.N. 28.062.007.01  
(2 HM-1S to 1 HM-1S) Mono Subwoofer Cable  
M.S.P.N. 28.062.009.01  
Connections:  
Gray wire to pin 1,  
pin 2 no connection,  
pin 3 no connection.  
GRAY  
-
Connections:  
Gray wire to pin 1,  
pin 2 no connection,  
White wire to pin 3.  
Connections:  
pin 1 no connection,  
pin 2 no connection.  
White wire to pin 3.  
WHITE  
+
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S to HM-1S Subwoofer Cable  
Connector Assembly Procedure  
Boot  
Coupling Ring  
Cord Connector  
Cable  
Cable Clamp Housing  
Contact Pins  
Step 1:  
Feed the end of the cable through the boot, cable clamp housing,  
and coupling ring in the order and position shown.  
Cord Connector  
Dot pin 1  
Cable  
Solder  
9/32"  
3/8" Max.  
indicator  
3
1
1
3
7/32"  
2
Contact Pins  
Step 2:  
FOR STEREO CABLES: Strip cable as shown and begin soldering conductors to pins starting  
with the Gray wire to pin 1, pin 2 no connection, and the White wire to pin 3.  
FOR MONO CABLES: See wiring instructions on page 6.  
Cord Connector  
Cord Connector  
Tab  
Tab  
Coupling Ring  
Side notch  
Step 3:  
Align coupling ring's tabs with cord connector's side notches and push  
the coupling ring onto cord connector.  
Clamp  
Clamp  
Lock  
Step 4:  
Push the cable clamp housing foward until it locks into the connector body  
and snap the two clamps into their compartments.  
Step 5:  
Push the boot all the way foward to seat tightly onto the cable clamp housing.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Subwoofer Performance Verification  
There are two methods of verifying that the phase relationship between the HM-1S and its subwoofer. One method is  
free field, the other is a ground plane measurement in half space.  
Free Field:  
Place the HM-1S directly above and coplanar to the subwoofer as pictured below:  
Place a calibrated measurement microphone 1 meter, on axis to the tweeter of the HM-1S as pictured below:  
Using the noise or other broadband test signal, perform a transfer function of the HM-1S. Start with the subwoofer  
disconnected.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S on axis at 1 meter, free field.  
This represents a typical response of the HM-1S in free-field environment, on axis at 1 meter. This measurement  
was performed in the large anechoic chamber at MSLI.  
Connect the subwoofer and measure the combined response of the system.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S with in-phase subwoofer on axis at 1 meter, free field.  
This represents a typical response of the HM-1S and subwoofer, in phase, in a free field environment on axis at 1  
meter. This measurement was performed in the large anechoic chamber at MSLI. This response indicates a  
complementaryphaserelationshipbetweentheHM-1Sandsubwoofer.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If the subwoofer is out of phase, the combined response will have a significant loss of energy compared to the  
overall response at around 82 Hz as illustrated below:  
HM-1S with out-of-phase subwoofer on axis at 1 meter, free field.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This represents a typical response of the HM-1S and subwoofer out-of-phase phase, in a free field environment on-  
axis at 1 meter. This measurement was performed in the large anechoic chamber at MSLI.  
If your system response indicates a phase reversal please contact Meyer Sound Technical Support for assistance.  
Half Space:  
To verify the system performance in half space you must perform a ground-plane measurement. This type of  
measurement is not desirable for system calibration and should only be used to verify the performance of the  
subwoofer. Place the HM-1S next to the subwoofer on the flat ground and position the calibrated measurement  
microphone one meter on axis from the tweeter of the HM-1S as pictured below:  
Using noise or other broadband test signal, perform a transfer function of the HM-1S. Start with the subwoofer  
disconnected.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S on axis at 1 meter, ground plane.  
This represents a typical ground-plane response of the HM-1S, on-axis at 1 meter. Keep in mind that any surface  
close to the test space can create reflections which will change the response of the speaker.  
Connect the subwoofer to the HM-1S and measure the combined response of the system.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HM-1S with in-phase Subwoofer on axis at 1 meter, ground plane.  
This represents a typical ground-plane response of the HM-1S and subwoofer, in phase, at 1 meter. This response  
indicates a complementary phase relationship between the HM-1S and subwoofer.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If the subwoofer is out of phase the combined response will have a significant loss of energy compared to the  
overall response at around 82 Hz as illustrated below:  
HM-1S with out-of-phase Subwoofer on axis at 1 meter, ground plane.  
This represents a typical ground plane response of the HM-1S and subwoofer out-of-phase, in a ground plane  
environment on axis at 1 meter. If your system response indicates a phase reversal please contact Meyer Sound  
Technical Support for assistance.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The fans attach easily to the two bottom rear corners of  
the HM-1S. Use a 5/32” Allen wrench to remove the bottom  
screws and install the left and right fans according to the  
diagram below. The fans are shipped with a terminal plug  
keyed for insertion into the 2-pin fan output connector in  
the proper orientation only.  
Cooling and Fan Installation  
The HM-1S depends on natural convection to cool the  
heatsinks that absorb heat from the amplifiers and radiate  
the heat into the surrounding air space. Natural convection  
requires free air in back of, and underneath the HM-1S to  
allowairtoflowupovertheheatsinks. TheHM-1Sreaches  
an equilibrium temperature in approximately 15 minutes  
at a steady operating level.  
The fan speed is temperature controlled. At a heatsink  
temperature of 25°C, the fans turn on at half speed and  
increase speed linearly until reaching full speed at  
75°C.  
In free air, at a typical room temperature of 25°C, the HM-  
1S reaches an equilibrium temperature of  
Protection and Limiting  
40°C in a quiescent state (no audio signal);  
60°C at a moderate operating level (occasional  
limiting);  
ThefrontoftheHM-1ShastwoLEDsthatindicatepowerand  
limiter activity. The right LED is green when power is ap-  
plied. This LED turns red if thermal limiting occurs (de-  
scribedinthesectionCoolingandFanInstallation)untilthe  
temperature decreases to 75°C.  
75°C at the maximum operating level (continuous  
limiting), or at a moderate level with a subwoofer.  
If the temperature reaches 85°C, the thermal limiters  
activate (see Protection and Limiting) to prevent high  
source levels from further increasing the temperature  
and damaging the drivers and electronics. The thermal  
limiters provide 30 dB of muting until the temperature  
decreases to 75°C.  
The left LED indicates driver limiter activity with a vari-  
able intensity red color; full illumination occurs at thermal  
limiting.  
The HM-1S can be cooled by two fans, available as an  
accessory kit. The fans should be used if:  
Rigging  
the HM-1S is enclosed in a soffit or ceiling mount  
without adequate space for natural convection;  
the HM-1S is used in hot ambient temperatures or  
direct sunlight;  
!
Do not drill into the HM-1S Cabinet.  
theuserwishestoavoidaccidentalcontactwiththe  
heatsinks if the rear of the HM-1S is exposed.  
The HM-1S is not designed for use with rigging systems.  
For rigging needs, Use the Standard Contractors version  
HM-1cabinetswhichcanbeeasilyfittedforomni-mounts,  
and other rigging options.  
Installed fans blow air over the heatsink  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
Safety Summary  
English  
Français  
To reduce the risk of electric shock, disconnect the loud-  
speakerfromtheACadapterbeforeinstallingaudiocable.  
Reconnect the adapter only after making all signal con-  
nections.  
• Pourréduirelerisqued’électrocution, débranchezlaprise  
principale de l’haut-parleur, avant d’installer le câble  
d’interface allant à l’audio. Ne rebranchez le bloc  
d’alimentation qu’après avoir effectué toutes les connections.  
• Connect the AC adapter to a two-pole, three wire grounding  
mains receptacle. The receptacle must be connected to a  
fuse or circuit breaker. Connection to any other type of  
receptacle poses a shock hazard and may violate local  
electrical codes.  
• Branchez l’haut-parleur dans une prise de courant à 3  
dérivations (deux pôles et la terre). Cette prise doit être  
munie d’une protection adéquate (fusible ou coupe-circuit).  
Le branchement dans tout autre genre de prise pourrait  
entraîner un risque d’électrocution et peut constituer une  
infractionàlaréglementationlocaleconcernantlesinstal-  
lations électriques.  
• Do not install the loudspeaker in wet or humid locations.  
• Do not allow water or any foreign object to get inside the  
loudspeaker. Do not put objects containing liquid on, or  
near, the unit.  
• Ne pas installer l’haut-parleur dans un endroit où il y a de  
l’eau ou une humidité excessive.  
• Ne pas laisser de l’eau ou tout objet pénétrer dans l’haut-  
parleur. Ne pas placer de r´cipients contenant un liquide  
sur cet appareil, ni à proximité de celui-ci.  
To reduce the risk of overheating the loudspeaker, avoid  
exposing it to direct sunlight. Do not install the unit near  
heat emitting appliances, such as a room heater or stove.  
• Pour éviter une surchauffe de l’haut-parleur, conservez-la  
à l’abri du soleil. Ne pas installer à proximité d’appareils  
dégageant de la chaleur tels que radiateurs ou appareils  
de chauffage.  
• Thisloudspeakercontainspotentiallyhazardousvoltages.  
Do not attempt to disassemble the unit. The unit contains  
no user serviceable parts. Repairs should be performed  
only by factory trained service personnel.  
• Ce haut-parleur contient des circuits haute tension  
présentant un danger. Ne jamais essayer de le démonter.  
Il n’y a aucun composant qui puisse être réparé par  
l’utilisateur.Touteslesréparationsdoiventêtreeffectuées  
par du personnel qualifié et agréé par le constructeur.  
Deutsch  
Español  
• UmdieGefahreineselektrischenSchlagesaufeinMinimum  
zu reduzieren, den Lautsprecher vom Stromnetz trennen,  
bevor ggf. ein Audio-Schnittstellensignalkabel  
angeschlossenwird. DasNetzkabelerstnachHerstellung  
aller Signalverbindungen wieder einstecken.  
• Para reducir el riesgo de descarga eléctrica, desconecte  
de la red el altoparlante antes de instalar el cable de  
señalización de interfaz de la segnale. Vuelva a conectar  
el conductor flexible de alimentación solamente una vez  
efectuadas todas las interconexiones de señalizatción.  
• DerLautsprecheraneinegeerdetezweipoligeDreiphasen-  
Netzsteckdoseanschließen. DieSteckdosemußmiteinem  
geeigneten Abzweigschutz (Sicherung oder  
Leistungsschalter) verbunden sein. Der Anschluß der  
unterbrechungsfreienStromversorgunganeinenanderen  
Steckdosentyp kann zu Stromschlägen führen und gegen  
die örtlichen Vorschriften verstoßen.  
• Conecteelaltoparlanteauntomacorrientebipolarytrifilar  
con neutro de puesta a tierra. El tomacorriente debe estar  
conectado a la protección de derivación apropiada (ya  
sea un fusible o un disyuntor). La conexión a cualquier  
otro tipo de tomacorriente puede constituir peligro de  
descarga eléctrica y violar los códigos eléctricos locales.  
• No instale el altoparlante en lugares donde haya agua o  
humedad excesiva.  
• Der Lautsprecher nicht an einem Ort aufstellen, an dem  
sie mit Wasser oder übermäßig hoher Luftfeuchtigkeit in  
Berührung kommen könnte.  
• No deje que en el altoparlante entre agua ni ningún objeto  
extraño. No ponga objetos con líquidos encima de la  
unidad ni cerca de ella.  
• Darauf achten, daß weder Wasser noch Fremdkörper in  
das Innere den Lautsprecher eindringen. Keine Objekte,  
die Flüssigkeit enthalten, auf oder neben die  
unterbrechungsfreie Stromversorgung stellen.  
• Parareducirelriesgodesobrecalentamiento, noexponga  
la unidad a los rayos directos del sol ni la instale cerca de  
artefactos que emiten calor, como estufas o cocinas.  
• Um ein Überhitzen dem Lautsprecher zu verhindern, das  
GerätvordirekterSonneneinstrahlungfernhaltenundnicht  
in der Nähe von wärmeabstrahlenden Haushaltsgeräten  
(z.B. Heizgerät oder Herd) aufstellen.  
• Este altoparlante contiene niveles de voltaje peligrosos  
en potencia. No intente desarmar la unidad, pues no  
contiene piezas que puedan ser repardas por el usuario.  
Lasreparacionesdebenefectuarseúnicamenteporparte  
del personal de mantenimiento capacitado en la fábrica.  
• Im Inneren diesem Lautsprecher herrschen potentiell  
gefährliche Spannungen. Nicht versuchen, das Gerät zu  
öffnen. EsenthältkeinevomBenutzerreparierbarenTeile.  
Reparaturen dürfen nur von ausgebildetem  
Kundenienstpersonal durchgeführt werden.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear Panel Connectors  
AudioInputSignal  
(femaleXLR)  
6 A  
FanOutput  
(2-pinterminalplug)  
CircuitBreaker  
Dimensions  
All units in inches  
HM-1SFront  
HM-1SSide  
HM-1STop  
HM-1SSubFront  
HM-1SSubSide  
HM-1S weighs 11.0 lb (5.0 kg);  
HM-1S Subwoofer weighs 33 lb (15 kg)  
MeyerSoundGermanyGmbH  
Carl Zeiss Strasse 13  
D-56751 Polch  
Meyer Sound Laboratories, Inc.  
2832 San Pablo Avenue  
Berkeley, California 94702  
Telephone: 510 - 486 - 1166  
Germany  
Telephone: 26 54 96 00 58  
FAX:  
510 - 486 - 8356  
FAX:  
26 54 96 00 59  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kustom Stereo Amplifier Dual 30 RC User Manual
Lenovo Headphones 0C53113 User Manual
Lenovo Laptop 3000 C Series User Manual
Lexmark Printer 24T7401 User Manual
LG Electronics Computer Monitor 57M User Manual
Lux Products Thermostat P621Ia User Manual
Lux Products Thermostat T20 1141 User Manual
Mackie Speaker HRS150 User Manual
Makita Saw 2703X1 2703 2702X1 2702 User Manual
Maxim Network Card USBTO232 User Manual