Metrologic Instruments Scanner MS2x20 Series User Manual

METROLOGIC INSTRUMENTS, INC.  
MS2x20 Stratos® Series  
Configuration Addendum  
Mettler Toledo Diva Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
IMPORTANT NOTES - BEFORE YOU START ................................................................. 1  
IBM 3rd Generation 46xx ...................................................................... 26  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
IBM 3rd Generation 46xx ...................................................................... 35  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT NOTES - BEFORE YOU START  
It is important to read carefully the notes marked with a  
symbol on the pages  
contained in this manual. Not all configuration codes are designed to be used for  
both a single and dual cable scanner/scale system. Many of the configuration  
bar codes require additional steps before the unit can be configured and placed  
into service. Most of the bar codes in this addendum were designed to be used  
with a Stratos model that includes a scale. The text marked with a  
symbol will  
provide important additional information about the restrictions and uses of the bar  
codes shown.  
All of the bar codes in this manual require:  
The scanner/scale to have a firmware number of 15367 or higher  
All configuration bar codes must be scanned with the vertical window  
The Unit Configuration bar codes (located on pages 3 and 4 of this  
addendum guide) require the scale security seal to be broken.  
If the scale security seal is broken, it must be sealed and certified by local  
Weights and Measures authorities after the scale calibration process has been  
completed. The scanner/scale cannot be placed in service until it is sealed and  
certified by the proper authorities.  
For further details on calibration procedures for Weights and Measures  
certification, refer to the Scale Operation: Calibration section of the Stratos  
Installation and User’s Guide.  
The certification of the weighing mechanism of the scale version of  
this scanner is subject to federal, state and local Weights and  
Measures statutes and regulations and can only be performed by  
authorized government agencies and/or their duly registered  
agents. Each time the scale or weighing mechanism is calibrated,  
it should be properly sealed with a paper seal or a wire seal prior to  
being placed into service in commerce.  
It is the responsibility of the owner of the scale to confirm  
compliance with the relevant Weights and Measures statutes and  
regulations applicable in your area by checking with the appropriate  
government agency before placing a newly calibrated unit into  
service or removing any official seals.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT NOTES - BEFORE YOU START  
Important Bar Codes  
Scale Save Data Bar Code.  
The Scale Save Data bar code must be scanned last to “save” the changes in the  
scale’s memory. The scale will then reset and begin normal operation. This is  
required only for scale configuration items – not for calibration.  
Scale Save Data  
³
9
9
6
0
4
5
Scale Type Bar Code.  
The Stratos scanner should have been already programmed to recognize the  
type K Diva scale. If, for any reason, the scanner’s non-volatile memory is lost,  
the following bar code must be scanned to reprogram the scanner for the  
type K Diva scale.  
Type K Diva Scale  
³
4
4
6
5
1
0
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE/LOAD CELL CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Unit Configuration (Pounds)  
For Kilogram weight units see page 4.  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 must be in scale service mode to use these  
bar codes.  
Pounds Calibration  
Set the scale measuring range from  
0.00 to 30.00 pounds.  
³
9
9
6
0
4
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE/LOAD CELL CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Unit Configuration (Kilograms)  
For Pound weight units see page 3.  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 must be in scale service mode to use these  
bar codes.  
Kilograms Calibration  
Set the scale measuring range from  
0.000 to 15.000 kilograms.  
³
9
9
6
0
4
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Pole Display Configuration  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale Display  
Set the scale to use a single-line weight only  
Single-Line Weight Only  
display to show all scale activity.  
The single-line display must be plugged into  
the Scale to Display connector on the  
MS2xx0 (see Figure 1).  
³
9
9
6
0
0
3
Figure 1. Location of Scale to Display Connector  
Scale Display  
4-line Price Computing  
Set the scale to use a 4-line price computing  
display to show all scale activity.  
The 4-line display must be plugged into the  
Scale to Display connector on the MS2xx0  
(see Figure 1).  
³
9
9
6
0
0
9
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Pole Display Configuration  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale Has No Display  
Set the scale to not require a remote  
display. All weights are expected on a POS  
terminal display.  
A remote display can not be plugged into  
the Scale to Display connector on the  
MS2xx0 (see Figure 1).  
³
9
9
6
0
0
4
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Scale Settling Filter Configuration  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
The scale’s filter setting allows the unit to withstand a certain amount of vibration  
from the checkout counter. A stronger filter allows for more vibration to be  
absorbed but the weight may take a little longer to settle. Scales are normally  
shipped with a loose filter.  
* Scale = Loose Filter  
Loose filter setting for low vibration  
environments.  
* Factory Default Setting  
³
9
9
6
0
0
5
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Scale Settling Filter Configuration  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = Medium Filter  
Medium filter setting for moderate vibration  
environments.  
³
9
9
6
0
0
6
Scale = Strong Filter  
Strong filter setting for high vibration  
environments.  
³
9
9
6
0
0
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Scale Internal Beeper  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale Beep On  
Enable the internal scale beeper to beep  
when remote display keys are depressed.  
³
9
9
6
0
9
0
*Scale Beep Off  
Turn off the internal beeper inside the scale.  
This is the desired default as the scanner  
beeper is the main tone generator.  
* Factory Default Setting  
³
9
9
6
0
9
1
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Zero Cursor  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Zero Cursor Off  
Turn off the zero cursor that appears on the  
display when the scale is in the zero weight  
area.  
³
9
9
6
0
9
2
*Zero Cursor On  
Enable the zero cursor to appear on the  
display when the weight is within the zero  
weight area.  
* Factory Default Setting  
³
9
9
6
0
9
3
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Single or Dual Cable Scale Configuration Bar Codes  
Quantitative Separator  
The following bar codes can be used to configure a Single or  
Dual Cable MS2xx0.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Decimal Pt Separator  
Use a decimal point to separate the units  
from fraction values on the remote display.  
³
9
9
6
0
9
4
Comma Separator  
Use a comma to separate the units from  
fraction values on the remote display.  
³
9
9
6
0
9
5
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = EPOS Protocol  
Set the scale RS232 protocol to  
Serial EPOS.  
Communication Port Settings:  
2400 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
6
0
1
3
Even Parity  
Set the scale RS232 protocol to  
Modified Serial EPOS.  
This Protocol does not require the POS  
terminal to send the weight back to the scale  
for validation.  
Scale = EPOS2 Protocol  
Communication Port Settings:  
2400 Baud  
7 Data Bits  
1 Stop Bit  
Even Parity  
³
9
9
6
0
1
4
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = 8217 Protocol  
Set the scale RS232 protocol to 8217.  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
6
0
5
0
Even Parity  
Scale = 8213 Protocol  
Set the scale RS232 protocol to 8213.  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
6
0
5
1
Even Parity  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = ICL Protocol  
Set the scale RS232 protocol to Serial ICL.  
Communication Port Settings:  
2400 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
6
0
4
9
Even Parity  
Scale = EMEA  
Special Configuration  
Set the scale to EPOS protocol, kilograms,  
with a remote display, loose filter, no price  
computing, and scroll weight.  
Communication Port Settings:  
2400 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
6
0
4
1
Even Parity  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = NCI Protocol  
Reserved for Future NCI Protocol Variation  
³
9
9
6
0
1
6
Scale = NCI-ECR Protocol  
Set the scale RS232 protocol to NCI-ECR.  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
6
0
1
5
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
*NCI = 4 Status Bytes  
Set the number of status bytes reported by  
the NCI scale protocol to 4 status bytes.  
³
9
9
6
0
5
2
* Factory Default Setting  
NCI = 2 Status Bytes  
Set the number of status bytes reported by  
the NCI scale protocol to 2 status bytes.  
³
9
9
6
0
5
3
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
Scale Protocols  
The following bar codes will change scale parameters intended for a  
Dual Cable environment. To place the scanner in Dual Cable mode,  
please refer to page 24.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = Price  
Compute Setup  
Set the scale for price computing setup.  
Price computing display  
Dialog 06 Protocol  
9600 Baud  
Odd Parity  
7 Data Bits, 1 Stop Bit  
³
9
9
6
0
4
7
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
COM Port Settings (Baud Rate)  
The following bar codes will change scale parameters intended for a  
Dual Cable environment.  
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes  
below must be scanned after the Scale Protocol bar code in order to be  
effective.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = 2400 Baud Rate  
Set the scale baud rate for dual cable  
applications to 2400 baud.  
³
9
9
6
0
1
7
Scale = 9600 Baud Rate  
Set the scale baud rate for dual cable  
applications to 9600 baud.  
³
9
9
6
0
1
8
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
COM Port Settings (Baud Rate)  
The following bar codes will change scale parameters intended for a  
Dual Cable environment.  
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes  
below must be scanned after the Scale Protocol bar code in order to be  
effective.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = 19200 Baud Rate  
Set the scale baud rate for dual cable  
applications to 19200 baud.  
³
9
9
6
0
1
9
Scale = 38400 Baud Rate  
Set the scale baud rate for dual cable  
applications to 38400 baud.  
³
9
9
6
0
2
0
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
COM Port Settings (Data Bits & Parity)  
The following bar codes will change scale parameters intended for a  
Dual Cable environment.  
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes  
below must be scanned after the Scale Protocol bar code in order to be  
effective.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = 7 Data Bits,  
Odd Parity  
Set the scale communication parameters to  
7 data bits, odd parity.  
³
9
9
6
0
2
1
Scale = 7 Data Bits,  
Even Parity  
Set the scale communication parameters to  
7 data bits, even parity.  
³
9
9
6
0
2
2
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
COM Port Settings (Data Bits & Parity)  
The following bar codes will change scale parameters intended for a  
Dual Cable environment.  
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes  
below must be scanned after the Scale Protocol bar code in order to be  
effective.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = 8 Data Bits, No Parity Set the scale communication parameters to  
8 data bit, no parity.  
³
9
9
6
0
2
3
Scale = Odd Parity  
Set the scale communication to odd parity.  
³
9
9
6
0
2
4
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Dual Cable Scale Configuration Bar Codes  
COM Port Settings (Data Bits & Parity)  
The following bar codes will change scale parameters intended for a  
Dual Cable environment.  
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes  
below must be scanned after the Scale Protocol bar code in order to be  
effective.  
If the MS2xx0 is currently in a Dual Cable configuration, temporarily  
disconnect the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
Scale = Even Parity  
Set the scale communication to even parity.  
³
9
9
6
0
2
5
Scale = No Parity  
Set the scale communication to no parity.  
³
9
9
6
0
2
6
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALE CONFIGURATION BAR CODES  
Single Cable Scale Configuration Bar Codes  
Set Scale for Single Cable Communication  
If the MS2xx0 is currently in a Dual Cable configuration, disconnect  
and remove the Scale to Host cable prior to configuring the scale.  
The MS2xx0 does not need to be in scale service mode.  
The Scale Save Data bar code must be scanned last to save the  
changed configuration (see page 2).  
If your application requires single cable communication, scan the following bar  
code to set the scale configuration to the single cable defaults as required by the  
scanner.  
Scale = Single Cable Interface Set the scale to communicate via the  
single-cable interface.  
³
9
9
6
0
1
2
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Dual Cable Scanner Configuration Bar Codes  
Dual Cable Scanner Mode  
The following bar codes can be used to place, as well as configure, the  
scanner in Dual Cable mode.  
The MS2xx0 does not need to be in scale service mode to use the  
following bar codes.  
Scanner = Dual Cable Mode  
Places the scanner in Dual Cable mode.  
In a dual cable environment, the scanner  
and scale work independently. In this mode  
the host must have a dedicated RS232 port  
to receive the scale data and the bar code  
data is sent via its own cable to a separate  
communication port.  
³
9
9
9
9
5
3
Communication Port Settings:  
9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity  
There are two methods of configuring the scanner to a stand-alone protocol:  
Scan the Dual Cable Mode bar code on this page (if a scale is used)  
or  
If no scale is required, scan one of the single cable protocols on  
pages 27 - 36 and then scan the No Scale bar code on page 48.  
Dual Cable Scanner OPOS Mode  
Use this bar code when the scanner is to be  
Scanner Only  
Dual Cable OPOS Defaults  
setup using the OPOS drivers in the dual  
cable mode.  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
9
9
1
1
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Dual Cable Scanner Configuration Bar Codes  
Various Dual Cable Scanner Mode  
The following bar codes can be used to configure a Dual Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
REWE  
Dual Cable RS232 - REWE  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
2 Stop Bit  
³
9
9
7
0
1
0
Space Parity  
TESCO UK  
Dual Cable RS232 – TESCO UK  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
7
0
1
3
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Dual Cable Scanner Configuration Bar Codes  
IBM 3rd Generation 46xx and IBM OEM Full Speed USB  
The following bar codes can be used to configure a Dual Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
IBM 3rd Generation  
Communication  
When scanned the Stratos will operate  
as a table top scanner only.  
Terminal configuration, IBM 4690.OS  
terminal device group configuration  
screen select:  
#1 scanner or  
#3 scanner.  
³
9
9
9
9
5
2
IBM OEM Full Speed USB  
Communication Defaults  
When scanned the Stratos will operate  
as a table top scanner only.  
³
9
9
9
9
7
0
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
MSS Global  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
MSS Global, English  
Scanner/Scale, Single Cable RS232  
MSS Global Retail, English Units  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
9
9
5
1
MSS Global, Metric  
Scanner/Scale, Single Cable RS232 MSS  
Global Retail, Metric Units  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
9
9
5
0
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
ISS45  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
ISS45, English  
Scanner/Scale, Single Cable RS232  
ISS45, English Units  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
9
9
4
9
Even Parity  
ISS45, Metric  
Scanner/Scale, Single Cable RS232  
ISS45, Metric Units  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
9
9
4
8
Even Parity  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
OPOS  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
OPOS, English  
Scanner/Scale Single Cable RS232 OPOS,  
English Scale Defaults  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
9
9
5
8
OPOS, Metric  
Scanner/Scale Single Cable RS232 OPOS,  
Metric Scale Defaults  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
9
9
5
7
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
Retailix/NCR  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Retailix/NCR English  
Scanner/Scale Single Cable RS232  
Retailix/NCR Communication, English  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
9
9
5
6
Retailix/NCR Metric  
Scanner/Scale Single Cable RS232  
Retailix/NCR Comm, Metric  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
9
9
5
5
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
Retailix/OPOS  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Retailix / OPOS Metric  
Scanner/Scale Single Cable RS232 Retailix  
/ OPOS Communication, Metric  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
7
0
1
9
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
IT Retail  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
IT Retail, English  
Scanner/Scale Single Cable RS232  
IT Retail, English  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
7
0
0
8
IT Retail, Metric  
Scanner/Scale Single Cable RS232  
IT Retail, Metric  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
7
0
0
9
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
IBM Self Checkout System  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
IBM Self Checkout System,  
English  
Scanner/Scale Single Cable RS232 -  
IBM Self Checkout System, English  
Communication Port Settings:  
19200 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
7
0
2
0
Odd Parity  
Scanner/Scale Single Cable RS232 -  
IBM Self Checkout System, Metric  
IBM Self Checkout System,  
Metric  
Communication Port Settings:  
19200 Baud  
7 Data Bits  
1 Stop Bit  
³
9
9
7
0
2
1
Odd Parity  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
Various RS232 Single Cable Codes  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Morrison’s Tec Metric  
Scanner/Scale Single Cable RS232 –  
Morrison’s with Tec Display, Metric  
Communication Port Settings:  
9600 Baud  
7 Data Bits  
1 Stop Bit  
Odd Parity  
³
9
9
7
0
2
3
Reliance India Metric  
Scanner/Scale Single Cable RS232 -  
Reliance India, Metric  
Communication Port Settings:  
9600 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
³
9
9
7
0
1
9
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
IBM 3rd Generation 46xx  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
IBM 3rd Generation 46xx,  
English†  
Scanner/Scale Single Cable IBM 46xx,  
RS485, English (lbs.)  
³
9
9
9
9
6
0
Terminal Configuration, IBM 4690.OS Terminal Device Group  
Configuration screen select:  
#2 Scanner with integrated scale  
or  
#4 4696 scanner/scale  
IBM 3rd Generation 46xx,  
Metric†  
Scanner/Scale Single Cable IBM 46xx,  
RS485, Metric (kg)  
³
9
9
9
9
5
9
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Single Cable Protocols for POS Compatibility  
IBM OEM Full Speed USB  
The following bar codes can be used to configure a Single Cable  
MS2xx0.  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
IBM OEM  
Full Speed USB, English  
Table Top Scanner/Scale Single Cable,  
IBM OEM Full Speed USB, 4-Digit Weight  
Mode, English (lbs.)  
³
9
9
9
9
6
2
IBM OEM  
Full Speed USB, Metric  
Table Top Scanner/Scale Single Cable,  
IBM OEM Full Speed USB, 5-Digit Weight  
Mode, Metric (kg)  
³
9
9
9
9
6
1
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Full Speed USB Table Top/Handheld  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Scanner 4B Handheld  
Full Speed USB interface to 4B00h  
handheld usage.  
³
3
1
6
4
3
0
Scanner 4A Flatbed  
Full Speed USB interface to 4A00h  
table top usage.  
³
3
1
6
4
1
0
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Full Speed USB Table Top/Handheld  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Scanner/Scale 4A/6E  
Table Top  
Full Speed USB interface to the  
4A00h/6E00h table top scanner/scale  
usage.  
This option is only compatible with Stratos  
models that have a scale.  
³
3
1
6
4
4
0
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Special Function ACK  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Enable Special  
Answer simple special functions with ACK.  
Function ACK Answer  
³
1
4
1
7
1
4
* Disable Special  
Function ACK  
³
1
4
1
7
0
4
* Factory Default Setting  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Prefix/Suffix  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Use Protocol Prefix/Suffix  
Add protocol prefixes and suffixes to the  
bar code.  
³
1
4
1
7
1
5
* Program the  
Prefix/Suffix Separate  
³
1
4
1
7
0
5
* Factory Default Setting  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
3x-30 Acknowledge Responses  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
No 3x-30 Answer  
This bar code will inhibit all ‘simple  
acknowledge’ (3x-30) answers to POS or  
OPOS commands.  
³
1
4
1
7
1
0
*3x-30 Answer  
The scanner will answer all NCR and OPOS  
commands that require a 3x-30  
acknowledgement.  
³
1
4
1
7
0
0
* Factory Default Setting  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Special Function Command Responses  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Spec Func Ans 3x30  
Answer Special Function commands in the  
3x-30 format as opposed to the Ack / Nak  
which is the norm.  
³
1
4
1
9
1
4
*Spec Func Ans Ack  
Answer Special Function commands in the  
Ack / Nak format.  
³
1
4
1
9
0
4
* Factory Default Setting  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Special Function Command Responses  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Spec Func 30-30 Status  
Returns Special Function commands in the  
30-30 status as opposed to the 33-30 status.  
Note: Requires ‘Spec Func Ans 3x-30’ on  
page Error! Bookmark not defined. to be  
set.  
³
1
4
2
2
1
5
*No Spec Func 30-30 Status  
Disables redirection of Special Function  
3x-30 status to 30-30 status.  
³
1
4
2
2
0
5
* Factory Default Setting  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Special Function Command Responses  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
No Command Reject Answer  
This bar code will ignore sending a  
command reject answer to the POS mode.  
³
1
4
2
1
1
7
*Send Command Reject  
This bar code will send command reject  
answer to the POS if the command is  
rejected by the scanner.  
Answer  
³
1
4
2
1
0
7
* Factory Default Setting  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Special Function Command Responses  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
No Spec Func Answer  
This bar code will ignore sending a special  
function response answer in POS mode.  
³
1
4
2
1
1
6
*Spec Func Answer  
This bar code will send a special function  
response answer to the POS.  
³
1
4
2
1
0
6
* Factory Default Setting  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
BCC in POS communications  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Skip BCC in messages  
This bar code will tell the scanner to NOT  
expect or transmit the Block Check  
Character in all message transmissions..  
³
1
4
1
4
1
0
*Add BCC in messages  
The scanner will expect and answer all  
messages with the Block Check Character  
included.  
³
1
4
1
4
0
0
* Factory Default Setting  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
3 Scale Status Bytes  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Enable  
3 Scale Status Bytes  
Required for applications where the host  
system display is the primary scale display  
and there is no remote pole display  
connected directly to the scanner/scale unit.  
³
1
2
4
8
1
3
Disable  
3 Scale Status Bytes  
³
1
2
4
8
0
3
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Scale Options  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
5-Digit Weight  
Sets the English Mode weight to 5-digits, as  
in xx.yyy pounds.  
In order to work properly, this bar code must  
be scanned AFTER scanning one of the  
English configuration bar codes found on  
pages 27 - 36.  
³
1
4
1
0
1
0
Scan the No Scale bar code:  
1. If no scale is installed and one of the  
single cable protocol bar codes found  
on pages 27 - 36 has already been  
scanned.  
No Scale  
2. If the scale is in a dual cable  
environment and one of the single cable  
protocol bar codes found on  
pages 27 - 36 has already been  
scanned.  
³
1
4
1
4
0
7
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
Remote Display  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
No Remote Display  
When no remote display is installed, scan  
the No Remote Display bar code AFTER  
scanning one of the configuration bar codes  
found on pages 27 - 36 to remove the  
scale’s display from the scanner memory.  
³
1
4
0
9
0
2
Remote Display  
Add remote display to the scanner’s  
memory.  
³
1
4
0
9
1
2
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
StratosSTATS  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Activate StratosSTATS  
This bar code sets:  
a. StratosSTATS bar code data  
formatting active.  
b. Bar code Attempt Interval to  
0.5 seconds.  
c. Time to find supplements (code 128)  
to 0.3 seconds.  
³
9
9
7
0
1
7
Use StratosSTATS monitor to test this  
output format. When used with a POS, it  
must have the capability to parse and  
recognize the additional data.  
*StratosSTATS Off  
Remove StratosSTATS data formatting from  
the bar code output transmission.  
³
9
9
7
0
1
8
* Factory Default Setting  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
StratosSTATS  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
Dual Stats Xmit  
Allows non-RS232 interfaces transmit  
normally without StratosSTATS and  
concurrently RS232 interfaces transmit with  
StratosSTATS.  
Recommended RS232 Settings:  
³
1
3
8
5
1
1
38400 Baud  
8 Data Bits  
1 Stop Bit  
No Parity  
No Inter-character Delay  
*No Dual Stats Xmit  
³
1
3
8
5
0
1
* Factory Default Setting  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Data Formatting  
StratosSTATS  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
Dual Xmit Carriage Return  
This bar code enables a secondary carriage  
return suffix to be used only for the dual  
StratosSTATS RS232 transmission.  
³
1
3
8
5
1
2
*No Dual Xmit Carriage Return Resets StratsSTATS RS232 dual  
transmission suffix.  
³
1
3
8
5
0
2
* Factory Default Setting  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional POS Related Functions  
Scanner Beep on Weight Sent  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Beep on Weight  
Request scanner beep when a successful  
weight is sent. This code should only be  
used for ‘weight on demand’ applications. If  
used with periodic weight request  
applications, the beeper will be continuously  
active (ON).  
³
1
4
1
9
1
7
*Disable  
Beep on Weight  
When no beep on weight is desired.  
³
1
4
1
9
0
7
* Factory Default Setting  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Related Functions  
Restrict In-Store Codes  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Restrict In-Store Codes  
This bar code places tighter restrictions on  
in-store codes. These codes are:  
EAN13 Sys2  
UPCA Sys2 and Sys4  
³
1
2
5
8
1
0
*No Restrict In-Store Codes  
Disable restrictions on in-store codes.  
³
1
2
5
8
0
0
* Factory Default Setting  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Related Functions  
Scale Shadow Mode  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Scale Shadow Mode  
This bar code sets the scale to the highest  
priority to allow for frequent scale - POS  
commands.  
This bar code is only to be used in single  
cable scale mode.  
³
1
4
2
2
1
7
*No Scale Shadow Mode  
Disables the Scale Shadow Mode.  
³
1
4
2
2
0
7
* Factory Default Setting  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional POS Related Functions  
Scanner Razz on Not-On-File  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Razz on Not-On-File  
This bar code changes the audible to a razz  
signal when a Not-On-File command is  
received.  
³
1
4
2
1
1
5
*Beep on Not-On-File  
This bar code restores the beep as the Not-  
On-File audible.  
³
1
4
2
1
0
5
* Factory Default Setting  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional Scanner Configuration Bar Codes  
Horizontal Depth of Field  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
*Horizontal High DOF  
This bar code sets the DOF for all horizontal  
laser channels to High DOF, which allows  
the farthest scanning.  
³
2
1
8
7
0
2
* Factory Default Setting  
Horizontal Medium DOF  
This bar code sets the DOF for all horizontal  
laser channels to Medium DOF.  
³
2
1
8
7
1
2
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional Scanner Configuration Bar Codes  
Horizontal Depth of Field  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
Horizontal Close DOF  
This bar code sets the DOF for all horizontal  
laser channels to Close DOF.  
³
2
1
8
7
2
2
Horizontal Ultra Close DOF  
This bar code sets the DOF for all horizontal  
laser channels to Ultra Close DOF.  
³
2
1
8
7
3
2
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Additional Scanner Configuration Bar Codes  
Vertical Depth of Field  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
*Vertical High DOF  
This bar code sets the DOF for the vertical  
laser channels to High DOF, which allows  
the farthest scanning.  
³
2
1
8
7
0
0
* Factory Default Setting  
Vertical Medium DOF  
This bar code sets the DOF for vertical laser  
channels to Medium DOF.  
³
2
1
8
7
1
0
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Additional Scanner Configuration Bar Codes  
Vertical Depth of Field  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Do not scan these bar codes unless instructed by a Metrologic  
Representative.  
Vertical Close DOF  
This bar code sets the DOF for the vertical  
laser channels to Close DOF.  
³
2
1
8
7
2
0
Vertical Ultra Close DOF  
This bar code sets the DOF for vertical laser  
channels to Ultra Close DOF.  
³
2
1
8
7
3
0
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
Auxiliary Port  
StratosSCHOOL™  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
Auxiliary History Report  
The Auxiliary port may be used to download  
or clear data to StratosSCHOOL™.  
The two commands that can be used are  
Upload Scanner Data and Clear Scanner  
Data within the Serial Program Interface box  
on the StratosSCHOOL™ screen.  
³
9
9
7
0
1
1
Auxiliary Program Cable  
(MLPN 57-57008x-N-3) is required  
for this feature.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Auxiliary Port  
Quick Start for a Secondary Metrologic Scanner  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
STEP 1  
Use the Stratos to scan the following bar code. This bar code will configure  
the Stratos’ auxiliary port to accept a Metrologic scanner as the secondary  
scanner.  
Enable Stratos Auxiliary Port  
³
4
3
7
3
2
0
The auxiliary input port’s data format must match the main output format  
of the secondary scanner  
STEP 2  
Configure the secondary scanner to match the auxiliary port’s data format.  
Use the Secondary Scanner to scan the following bar codes in the order  
shown.  
Enter Configuration Mode  
³
9
9
9
9
9
9
Enable Auxiliary Output  
³
1
2
4
8
1
7
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
Auxiliary Port  
Quick Start for a Secondary Metrologic Scanner  
Configuration sequence continued from previous page.  
Set Stratos Format  
³
4
3
7
5
2
0
Disable Secondary  
Scanner Beeper  
³
3
1
8
5
0
5
Enable Communication  
Time Out  
³
1
1
8
4
1
2
Disable CR Suffix  
³
1
1
6
6
0
3
Disable LF Suffix  
³
1
1
6
6
0
2
Exit Configuration Mode  
³
9
9
9
9
9
9
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Device Types  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
*No EAS Device  
No EAS device is connected.  
³
3
3
7
2
0
0
* Factory Default Setting  
EAS Device Type 1  
³
3
3
7
2
1
0
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Device Types  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS Device Type 2  
³
3
3
7
2
2
0
EAS Device Type 3  
³
3
3
7
2
3
0
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Device Types  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS Device Type 4  
³
3
3
7
2
4
0
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Timeout  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
*EAS = 0 seconds  
³
8
4
6
0
0
0
* Factory Default Setting  
EAS = 1 second  
³
8
4
6
0
0
1
0
0
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Timeout  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS = 2 seconds  
³
8
4
6
0
0
2
0
0
EAS = 3 seconds  
³
8
4
6
0
0
3
0
0
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Timeout  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS = 4 seconds  
³
8
4
6
0
0
4
0
0
EAS = 5 seconds  
³
8
4
6
0
0
5
0
0
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Timeout  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS = 7 seconds  
³
8
4
6
0
0
7
0
0
EAS = 10 seconds  
³
8
4
6
0
1
0
0
0
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Timeout  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS = 15 seconds  
³
8
4
6
0
1
5
0
0
EAS = 20 seconds  
³
8
4
6
0
2
0
0
0
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Connection  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
*EAS Digital Aux Port  
The EAS signals use the RTS and CTS line  
of the Auxiliary RS232 In connector.  
³
1
4
6
1
0
0
* Factory Default Setting  
EAS Digital Host Port  
The EAS signals use the RTS and CTS lines  
of the scanner RS232 to Host connector.  
³
1
4
6
1
1
0
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Connection  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS RS232 on Aux Port  
This bar code allows the EAS RS232 signal  
to use the Tx Out and Rx In lines of the  
scanner to Aux RS232 In connector.  
³
1
4
6
1
1
1
*No EAS RS232 on Aux Port  
There is no EAS RS232 signal (Tx Out and  
Rx In) used on the scanner Aux RS232 In  
connector.  
³
1
4
6
1
0
1
* Factory Default Setting  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Connection  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS RS232 on Host Port  
This bar code allows the EAS RS232 signal  
to use the Tx Out and Rx In lines of the  
scanner to Host RS232 In connector.  
³
1
4
6
1
1
2
*No EAS RS232 on Host Port  
There is no EAS RS232 signal (Tx Out and  
Rx In) used on the scanner to Host RS232  
In connector.  
³
1
4
6
1
0
2
* Factory Default Setting  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
Continuous Mode  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
EAS Continuous Mode  
When in continuous mode and the scanner  
is enabled, the EAS will always be online to  
deactivate an EAS tag.  
³
1
4
6
1
1
5
*EAS Interlock Mode  
This bar code establishes EAS is used in the  
Interlocked mode.  
³
1
4
6
1
0
5
* Factory Default Setting  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Deactivation  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Blink Scan LED on  
Deactivation  
The scanner will blink the scan LED upon  
receipt of an EAS deactivate acknowledge  
signal.  
³
1
4
6
1
1
3
*No Blink LED on Deactivation Do not blink the scan LED upon receipt of  
an EAS deactivate acknowledge signal.  
³
1
4
6
1
0
3
* Factory Default Setting  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Deactivation  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Fast Beep on Deactivation  
Fast beep the scanner’s beeper receipt of  
an EAS deactivate acknowledge signal.  
³
1
4
6
1
1
4
*No Beep on Deactivation  
Do not fast beep the scanner’s beeper  
receipt of an EAS deactivate acknowledge  
signal.  
³
1
4
6
1
0
4
* Factory Default Setting  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
EAS Deactivation  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
Volume Switch = Manual  
The volume switch is used for manual EAS  
deactivation switch.  
³
1
4
6
1
1
6
*Volume Switch = Normal  
Volume switch is used for normal volume  
function.  
³
1
4
6
1
0
6
* Factory Default Setting  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
Sensormatic ScanMax Pro  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
The RS232 EAS cable must be connected to one of the RS232 scanner  
ports.  
EAS Function #1  
For Sensormatic ScanMax Pro, get EAS’s  
deactivation count and transmit the  
information over the current scanner  
interface.  
³
9
9
8
0
6
5
EAS Function #2  
For Sensormatic ScanMax Pro, get EAS’s  
device type and transmits the information  
over the current scanner interface.  
³
9
9
8
0
6
6
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SCANNER CONFIGURATION BAR CODES  
EAS Bar Codes  
Sensormatic ScanMax Pro  
The following codes do not require that the MS2xx0 to be in scale  
program mode.  
The RS232 EAS cable must be connected to one of the RS232 scanner  
ports.  
EAS Function #3  
For Sensormatic ScanMax Pro, get EAS’s  
hardware version, software version, and  
serial number and transmit the information  
over the current scanner interface.  
³
9
9
8
0
6
7
ScanMax RS232 Defaults  
For Sensormatic ScanMax Pro, RS232  
default setup.  
AUX port connect  
5 second timeout  
blink LED on deactivate  
³
9
9
9
9
0
9
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCANNER TEST BAR CODES  
Supplemental Tests  
Display Software Numbers  
The following codes do not require that the MS2xx0 to be in scale  
service mode.  
These codes are for test purposes only.  
The following code will display software #’s on the 2-digit diagnostic display.  
The lasers will be turned off while the numbers are being displayed. The first  
number is the main decode processor software number. The second number is  
the I/O processor’s software number. Since only 2 digits can be displayed at a  
time, the following sequence is used as an example of what may be observed:  
2-Digit  
Display  
Description of each sequentially displayed sets of digits.  
(Example shown will represent: ‘ 15269’ ‘ 15138’)  
The first digit of the five main decode processor software number  
appears right justified.  
x 1  
5 2  
6 9  
x x  
The second and third digits.  
The forth and fifth digits.  
Pause before next set of numbers.  
The first digit of the five digit I/O processor software number  
appears right justified.  
x 1  
5 1  
3 8  
The second and third digits.  
The forth and fifth digits.  
x = Blank / No Digit Displayed  
After the last sets of digits are displayed, the scanner resumes scanning  
operation. If the current interface does not use an I/O processor, the software  
number may appear ‘ 0 00 00’. This capability exists in software 15269 and  
later.  
Display Software Number  
³
9
9
8
0
6
2
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NOTES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
May 2008  
Printed in the USA  
0 0 - 0 2 2 7 2 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kuhn Rikon Saw 10 300 User Manual
Liebert Power Supply GXTTM User Manual
Life Fitness Home Gym Elevation Series User Manual
Lincoln Electric Welder SVM132 A User Manual
Lincoln Electric Welder V450 PRO User Manual
Linksys Speaker System WML11B User Manual
Magellan Door MG32WK User Manual
Martin Audio Speaker WS218X User Manual
Meade Binoculars DB1 User Manual
Metra Electronics Automobile Accessories 99 1008 User Manual