MetroSelect™ Configuration Guide
MLPN 2407/February 2000
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Table of Contents
Introduction
iii
A
B
C
D
E
F
Section A: Code Types & Decode Rules
Section B: Supplements
Section C: Communications
Section D: Scanner Operation
Section E: Prefixes/Suffixes
Section F: Code Formatting
Section G: RS-232
G
H
I
Section H: Keyboard
Section I: OCIA
Section J: Light Pen Parameters
Section K: IBM 46xx
J
K
L
M
N
Section L: MS9500 Voyager™
Section M:Code Bytes
Section N: Miscellaneous Features
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
iii
MetroSelect™
Introduction
Your new scanner has been configured at the factory with default settings.
Many host systems have unique formats and protocol requirements. Therefore, Metrologic
provides a wide range of configurable features that may be selected using this bar code based
configuration tool. Once the configuration is completed, the scanner stores the settings in
nonvolatile memory (NOVRAM). NOVRAM saves the settings when the power is turned off.
Note: Every bar code with an “ * ” (asterisk) is a default setting.
Bar codes with a “~” (tilde) require multi-code configuration method.
Directions
The MetroSelect class of scanners can be bar code configured in two ways: Single Code
Method and Multi-Code Method.
Single Code Method: Most features can be enabled or disabled using the single code
method. Scan the bar code next to the feature. The scanner will give a “good scan” beep. A
multi-tone beep will follow to indicate the configuration has been saved to NOVRAM.
Multi-Code Method: All features can be enabled or disabled using the multi-code
method. A feature with a “~” requires the multi-code method. To use the multi-code
method, scan the “Enter/Exit Configuration Mode” code. Next, scan the codes for the
needed feature. Then scan the Enter/Exit Configuration Code to exit and save the configura-
tion changes. To abort a configuration change, power off the scanner before scanning the
Enter/Exit code.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Bar Code Configuration Methods
Single Code Method
1. Power up scanner
2. Scan the bar code for the desired feature
3. Observe a “good scan” beep, quickly followed by a multi-toned,
“save setting” beep.
Multi-Code Method
1. Power up scanner
2. Scan Enter/Exit Configuration Mode bar code
(3 beeps)
3. Scan bar code for the desired feature
(1 beep)
4. Scan Enter/Exit Configuration Mode bar code
(3 beeps) and save new configuration.
999999
Enter/ Exit
Configuration Mode
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
v
MetroSelect™
Need to start over?
Use the Recall Default bar code. This will erase all previous settings and return to the scanner’s default
communications protocol.
-Keyboard Wedge interface scanners will load keyboard wedge defaults.
-All other scanners load RS-232 defaults.
Note: Metrologic manufactures custom OEM scanners which load the OEM’s defaults. Section N will
explain how this affects “Metrologic Defaults.”
Recall Defaults
999998
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section A
Code Types and Decode Rules
UPC-EAN
A-1
Code 128
A-3
Code 39
A-4
Interleaved 2 of 5
Standard 2 of 5
Other 2 of 5 Codes
Codabar
A-6
A-8
A-9
A-10
A-11
A-11
A-12
A-13
A-15
A-16
Code 93
Code 11
Telepen
Plessey Codes
Other Decode Features
Configurable Code Lengths
A
Download from Www.Somanuals.com. All Manuals Search And Download.
A-1
MetroSelect™
UPC/ EAN
*Enable UPC/EAN
Disable UPC/EAN
100116
100106
*Enable UPC-A
Disable UPC-A
100216
100206
*Enable UPC-E
Disable UPC-E
100210
100200
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
*Enable EAN-13
Disable EAN-13
Disable EAN-8
100211
100201
*Enable EAN-8
100214
100204
A-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A-3
MetroSelect™
Code 128
*Enable Code 128
Disable Code 128
100113
100103
Enable UCC/EAN - 128
‘]C1’ Code formatting
*Disable UCC/EAN -128
‘]C1’ Code formatting
100314
100304
For Coupon Code 128,
see Section B.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Code 39
Disable Code 39
*Enable Code 39
100111
100101
Enable MOD 43
Check on Code 39
*Disable MOD 43 Check on
Code 39
100213
100203
When enabled, the scanner will only
scan Code 39 bar codes that have a
valid Modulo 43 check digit.
The scanner will not test Code 39
bar codes for a Modulo 43 check
digit.
Enable Full ASCII Code 39
100217
*Disable Full ASCII Code 39
100207
A-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A-5
MetroSelect™
Enable PARAF (Italian
Pharmaceutical Codes)
Support
*Disable PARAF Support
100205
100215
When enabled, the scanner will
convert Code 39 bar codes to
PARAF format.
When disabled, the scanner will not
convert Code 39 bar codes to PARAF
format.
Enable TRI-OPTIC Code
*Disable TRI-OPTIC Code
100302
100312
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Interleaved 2 of 5
*Enable Interleaved
2 of 5 (ITF)
Disable Interleaved
2 of 5 (ITF)
100105
100115
Enable MOD 10
Check on ITF
*Disable MOD 10
Check on ITF
100300
100310
When option disabled, the scanner will
not test Interleaved 2 of 5 (ITF) bar
codes for a Modulo 10 check digit.
When option enabled, the scanner will
only scan Interleaved 2 of 5 (ITF) bar
codes that have a Modulo 10 check
digit.
A-6
Download from Www.Somanuals.com. All Manuals Search And Download.
A-7
MetroSelect™
~ITF Symbol Length Lock 1
~ITF Symbol Length Lock 2
901700
901600
To specify a First ITF symbol length
lock, scan the above bar code and the
appropriate code bytes located in
Section M. RefertoMultiCodeMethod
onpageiii.
To specify a second ITF symbol length
lock, scan the above bar code and the
appropriate code bytes located in
Section M. RefertoMultiCodeMethod
onpageiii.
~ITF Minimum Symbol
Length
903400
TospecifyaminimumnumberofITF
characterstobedecoded, scantheabove
barcodeandtheappropriatecode bytes
locatedinSection M. RefertoMultiCode
Methodonpageiii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Standard 2 of 5
Enable Standard
2 of 5
*Disable Standard
2 of 5
100110
100100
~Standard 2 of 5 Symbol Length
901500
TospecifyaminimumnumberofITF
characterstobedecoded, scantheabove
barcodeandtheappropriatecodebytes
locatedinSection M. RefertoMultiCode
Methodonpageiii.
A-8
Download from Www.Somanuals.com. All Manuals Search And Download.
A-9
MetroSelect™
Other 2 of 5 Codes
Enable Matrix 2 of 5
100015
*Disable Matrix 2 of 5
100005
Enable 15 Digit
Airline 2 of 5
*Disable 15 Digit
Airline 2 of 5
100004
100014
*Disable 13 Digit
Airline 2 of 5
Enable 13 Digit
Airline 2 of 5
100303
100313
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable Hong Kong
2 of 5
*Disable Hong Kong
2 of 5
100306
100316
Codabar
*Enable Codabar
Disable Codabar
100104
100114
Enable Dual Field Codabar
*Disable Dual Field Codabar
100002
100012
A-10
Download from Www.Somanuals.com. All Manuals Search And Download.
A-11
MetroSelect™
Code 93
*Enable Code 93
Disable Code 93
100102
100112
Code 11
Enable Code 11
*Disable Code 11
100003
100013
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Telepen
Enable Telepen
*Disable Telepen
100007
100017
Enable ALPHA Telepen
*Disable ALPHA Telepen
100006
100016
DownloAad-1fr2om Www.Somanuals.com. All Manuals Search And Download.
A-13
MetroSelect™
Plessey Codes
Enable MSI Plessey
*Disable MSI Plessey
100202
100212
*No MSI Plessey
Check Digit
200704
This option will not test MSI Plessey bar
codes for a check digit.
Enable MSI Plessey MOD 10/10
Check Digit
*Enable MSI Plessey
Mod 10 Check digit
200724
200734
Test MSI Plessey bar codes for a single
Modulo 10 check digit.
Test MSI Plessey bar codes for a double
Modulo 10 check digit.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable UK Plessey
*Disable UK Plessey
100107
100117
*UK Plessey A
to X Conversion Disabled
UK Plessey A
to X Conversion Enabled
100706
100716
Disables UK Plessey A to X
Conversion.
Enables UK Plessey A to X
Conversion.
DownloAad-1fr4om Www.Somanuals.com. All Manuals Search And Download.
A-15
MetroSelect™
Other Decode Features
Enable Double Border
Required/Large Intercharacter
Space
*Disable Double Border
Required/Large Intercharacter
Space
100001
100011
~Minimum Symbol Length
901800
~Symbol Length Lock
901900
Omnidirectional default is 4. Single-line
default is 3. Combine this code with the
proper Code Bytes, to specify the
minimum number of characters in all
non-UPC/EAN bar codes.
This code combined with the proper
Code Bytes, locks the bar codes’ length
into place. Refer to Multi-Code
Method on page iii.
Refer to Multi-Code Method on page iii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Configurable Code Lengths
There are seven bar code lock lengths available. Specific code types can be assigned to a lock length.
While in programming mode, start with lock length 1, then scan three Code Byte bar codes from
Section M that represent the bar code length. (A table with the code type values can be found in
Section M) Refer to Multi-Code Method on page iii.
This process can be repeated for lock lengths 2 through 7.
~Code Lock #1:
Code Type
~Code Lock #1:
Length
902100
902000
~Code Lock #2: Code Type
~Code Lock #2: Length
902200
902300
DownloAad-1fr6om Www.Somanuals.com. All Manuals Search And Download.
A-17
MetroSelect™
~Code Lock #3:
Length
~Code Lock #3:
Code Type
902400
902500
~Code Lock #4:
Length
~Code Lock #4:
Code Type
902600
902700
~Code Lock #5:
Length
~Code Lock #5:
Code Type
902800
902900
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
~Code Lock #6:
~Code Lock #6:
Code Type
Length
903000
903100
~Code Lock #7:
Length
~Code Lock #7:
Code Type
903200
903300
A-18
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section B
Supplements
Two Digit Supplements
B-1
B-1
B-1
B-2
B-2
B-2
B-3
B-3
B-3
B-4
B-4
B-4
B-5
B-5
B-5
B-6
B-6
B-6
B-7
B-7
B-8
B-8
B-8
Two Digit Redundancy
Five Digit Supplements
Five Digit Redundancy
Supplements Required/Not Required
Remote Supplemental Requirement
Bookland (978) Supplement Requirement
977 (2 digit) Supplement Requirement
378/379 French Supplement Requirement
434/439 German Supplement Requirement
#System 2 Requires Supplements
#System 5 Requires Supplements
Coupon Code 128
Code 128 ‘]C1’ Extended Code Format
Code 128 Group Separators
400 msec to find Supplemental
200 msec to find Supplemental
100 msec to find Supplemental
Code ID’s with Supplements
Beep Once/Twice on Supplements
ISBN Check Digit Transmission
Bookland to ISBN Conversion
ISBN Re-formatting
B
Download from Www.Somanuals.com. All Manuals Search And Download.
B-1
MetroSelect™
Supplements
Enable Two Digit Supplements
101217
*Disable Two Digit Supplements
101207
*Enable Two Digit Redundancy
101212
Disable Two Digit Redundancy
101202
Twice before accepting data, the
scanner will scan the bar code plus
the 2 digit add on.
When Scanned, will not implement
the two digit redundancy feature.
*Disable Five Digit Supplements
101206
Enable Five Digit Supplements
101216
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
*Disable Five Digit
Redundancy
Enable Five Digit
Redundancy
101211
101201
When Scanned, will not implement
the five digit redundancy feature.
Twice before accepting data, the
scanner will scan the bar code plus
the five digit add on.
Supplements are Required
101213
*Supplements are not Required
101203
When chosen, all UPC/EAN labels
that are scanned must have a sup-
plement.
When chosen, all UPC/EAN labels do
not require a supplement to be
scanned.
*Disable Remote Supplemental
Requirement
Enable Remote Supplemental
Requirement
101416
101406
B-2
Download from Www.Somanuals.com. All Manuals Search And Download.
B-3
MetroSelect™
Enable Bookland
*Disable Bookland
(978) Supplement Requirement
(978) Supplement Requirement
101417
101407
*Disable 977 (2 digit)
Enable 977 (2 digit)
Supplemental Requirement
Supplemental Requirement
101314
101304
When enabled, the scanner will
require a 2 digit supplement be
scanned whenever an EAN-13 code
begins with 977.
When enabled, the scanner will not
require a 2 digit supplement be
scanned whenever an EAN-13 code
begins with 977.
*Disable 378/379 French
Supplemental Requirement
Enable 378/379 French
Supplemental Requirement
101313
101303
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable 434/439 German
Supplemental Requirement
*Disable 434/439 German
Supplemental Requirement
101415
101405
Enable #System 2 Requires
Supplements
*Disable #System 2 Requires
Supplements
101412
101402
Enable #System 5 Requires
Supplements
*Disable #System 5 Requires
Supplements
101215
101205
B-4
Download from Www.Somanuals.com. All Manuals Search And Download.
B-5
MetroSelect™
Enable Coupon Code 128
100315
*Disable Coupon Code 128
100305
Enable Code 128 ‘]C1’ Extended
Code Format
*Disable Code 128 ‘]C1’
Extended Code Format
101411
101401
When enabled, scanner transmits an
‘]C1’ at the beginning of the Code
128 portion of the coupon code.
When disabled, scanner will not trans-
mit on ‘]C1’ at the beginning of the
Code 128 portion of the coupon code.
Enable 128 Group Separators
101414
*Disable 128 Group Separators
101404
“GS” (1DH) character will notbe
transmittedwithcoupon Code128codes.
“GS” (1DH) character will be transmit-
ted with coupon Code 128 codes.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
200 msec to Find Supplemental
301320
400 msec to Find Supplemental
301340
With this option, the scanner will allot
200 milliseconds to “find” an add on
after a main UPC/EAN bar code has
been scanned.
With this option, the scanner will allot
400 milliseconds to “find” an add on
after a main UPC/EAN bar code has
been scanned.
*100 msec to Find Supplemental
301310
With this option, the scanner will allot
100 milliseconds to “find” an add on
after a main UPC/EAN bar code has
been scanned.
B-6
Download from Www.Somanuals.com. All Manuals Search And Download.
B-7
MetroSelect™
Enable Code ID’s with
Supplements
*Disable Code ID’s with
Supplements
101214
101204
*Beep Once on Supplements
118406
Beep Twice on Supplements
118416
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable ISBN Check Digit
Transmission
Disable ISBN Check Digit
Transmission
101315
101305
Not available with all models.
*Disable Bookland to ISBN
Conversion
Enable Bookland to ISBN
Conversion
101317
101307
Not available with all models.
*Disable ISBN
Re-Formatting
Enable ISBN
Re-Formatting
101316
101306
Not available with all models.
B-8
Download from Www.Somanuals.com. All Manuals Search And Download.
B-9
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section C
Communications
Enable Light Pen/Wand Communication
C-1
C-1
C-1
C-1
C-1
C-2
C-2
C-2
C-2
C-3
C-3
C-3
Enable RS-232
Load Keyboard Wedge Defaults
Enable Stand-Alone Keyboard Scanner
Enable Keyboard Wedge Emulation
Enable OCIAOutput
Load OCIA Defaults
Enable IBM 46xx Communication
Load IBM 46xx IBM Defaults
Enable No Communication Mode
Reserved
Reserved
Download from Www.SomanuaCls.com. All Manuals Search And Download.
C-1
MetroSelect™
Communications
Enable Light Pen/Wand
Communication
*Enable RS-232
415554
415524
When this option is enabled, the scanner
willworkwithRS-232+/-12Vserial
output.
Use this option if scanner should be
used in place of a light pen.
Load Keyboard Wedge Defaults
999994
Scan this before selecting Normal or
Stand Alone Mode.
Enable Keyboard Wedge Emulation
5155143
Enable Stand-Alone Keyboard
Scanner
5155153
Select if the scanner provides keyboard emu-
lationbyconvertingthescannedbarcodedata
tothePCkeyboardscancodeequivalent.
Allows scanner to be used without an
external keyboard.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable OCIA Output
Load OCIA Defaults
415544
999993
Selectthisoptionifthecommunications
requirementisan Optically Coupled
Interface Adapter(OCIA).Thisaclocked
(bythehost)serialinterface.
Scan this before selecting Enable
OCIA output
Enable IBM 46xx Communication
415504
Load IBM 46xx Defaults
999995
Select this option for IBM 46XX
SIOC/RS485 communications. Not all
scanners support this interface. The
correct interface board is required.
Scan this before selecting
IBM 46XX Defaults
C-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C-3
MetroSelect™
Enable No Communication Mode
415534
Select this option if the scanner does
not interface with the host device.
Reserved
415564
Reserved
917500
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section D
Scanner Operation
Configuration Mode Options
Scan Buffers
D-1
D-2
Redundant Scans
D-4
Miscellaneous Decode Features
Depth of Field Adjustments
Same Symbol Time Outs
LED Options
D-6
D-7
D-8
D-10
D-11
D-14
D-14
D-15
D-16
D-18
D-22
D-24
D-25
Beeper Options
Data Transmission Delays
Inter-Character
Inter-Record
Communication Timeout Options
Host Scanner Commands
Power Save Modes
Miscellaneous Features
Test Modes
Download from Www.Somanuals.com. AllDManuals Search And Download.
D-1
MetroSelect™
Configuration Mode
Allow Configuration Mode on
Power-Up
*Allow Configuration Mode
Anytime
118117
118107
Scanner can only enter MetroSet™
mode before any bar codes are
scanned.
Allow MetroSet™configurationatany
time.
Allow Configuration Labels on
Power-up
*Allow Configuration Labels
Anytime
118116
118106
Allows scanningofconfigurationbar
codesany time.
Once a product bar code is scanned
after power-up, the scanner will not
accept configuation bar codes.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Scan Buffers
2 Scan Buffers
*1 Scan Buffer
318000
318010
When enabled, the scanner will scan
2 bar codes in the scan field one time
each. These 2 bar codes will not be
scanned again until they are removed
from the scan field for the duration of
the same symbol time out.
When enabled, the scanner will scan
one bar code in the scan field and not
scan again until the bar code is
removed from the scan field for the
duration of the same symbol time
out.
3 Scan Buffers
318020
318030
Same function as 2 Scan Buffers, but
4 bar codes are in the scan field.
Same function as 2 Scan Buffers, but
3 bar codes are in the scan field.
5 Scan Buffers
318040
6 Scan Buffers
318050
Same function as 2 Scan Buffers,
but 6 bar codes are in the scan field.
Same function as 2 Scan Buffers, but
5 bar codes are in the scan field.
Download from Www.Somanuals.com. ADll-M2anuals Search And Download.
D-3
MetroSelect™
7 Scan Buffers
8 Scan Buffers
318060
318070
Same function as 2 Scan Buffers, but
7 bar codes are in the scan field.
Same function as 2 Scan Buffers, but
8 bar codes are in the scan field.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Redundant Scans
*0 Redundant Scans
301100
1 Redundant Scans
301110
Requires 1 good decode for a “good
scan.”
Requires 2 consecutive decodes of the
same bar code data for a “good
scan” .
2 Redundant Scans
301120
3 Redundant Scans
301130
Requires 3 consecutive...
Requires 4...
4 Redundant Scans
301140
5 Redundant Scans
301150
Requires 5...
Requires 6...
D-4
Download from Www.Somanuals.com. All Manuals Search And Download.
D-5
MetroSelect™
7 Redundant Scans
6 Redundant Scans
301160
301170
Requires 7...
Requires 8...
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Miscellaneous Decode Features
*Enable MAJIC
101113
Disable MAJIC
101103
Disable this feature when bar codes
are in good reading condition. This
will speed up decoding and improve
over all accuracy.
The Metrologic Algorithm for Joining
Incomplete Codes (MAJIC) aids in
deciphering damaged or incomplete
bar codes. Enable for more aggres-
sive decoding.
Optional Same Symbol Check
118113
*Normal Same Symbol Check
118103
Require 1 different character between
successive bar codes to consider the bar
code “new”.
Require 3 different characters between
successive bar codes to consider the bar
code “new”.
D-6
Download from Www.Somanuals.com. All Manuals Search And Download.
D-7
MetroSelect™
Depth of Field Adjustments
Do not change these settings unless instructed by a Metrologic representative.
*Optimize for Low Density Codes
418790
Optimize for High Density Codes
4187130
For use with omnidirectional
scanners only.
For use with omnidirectional
scanners only.
Fixed for High Density Codes
418700
Fixed for Medium Density
418710
For use with omnidirectional
scanners only.
For use with omnidirectional
scanners only.
Fixed for Low Density Codes
418720
For use with omnidirectional
scanners only.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Same Symbol Time outs
These numbers determine the length of time before a bar code can be rescanned afterit is removed from the scan field. Single
codefixedsettingsinmsecsofNo,50, 100,200,500,1200(1.2sec),2000(2.0sec)andinfiniteareavailable. Also,user-config-
urablevaluecan besetin user-configurableincrementsof50forarangeof50msecsto6350(6.35sec).
If using the MS9500 series, please go to Section L.
No Same Symbol Time Out
Same Symbol Time Out 100
msecs
818900
818920
*Same Symbol Time Out 500 msecs
8189100
Same Symbol Time Out 200
msecs
818940
Same Symbol Time Out 1200 msecs
8189240
Same Symbol Time Out 2000 msecs
8189400
Download from Www.Somanuals.com. ADll-M8anuals Search And Download.
D-9
MetroSelect™
Infinite Same Symbol Time Out
118917
~Variable Same Symbol Time-
out
918900
When selected, the scanner will not
repetitively scan the same bar code.
This option overrides the symbol res-
can time-outs.
In configuration mode, scan this bar
code and a code byte sequence from
Section M to set the same symbol
time out duration. Values range
from 001 to 127 (50 to 6350
msecs). Refer to MultiCode Method
on page iii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
LED Options
Flash Green LED if Rescan
Allowed
*Do Not Flash Green LED if
Rescan Allowed
118313
118303
This indicates same symbol timeout
has elapsed.
Reverse LED
Functions
*Normal LED
Functions
118312
118302
Red = Laser On
Green = Good Read
Green = Laser On
Red = Good Read
D-10
Download from Www.Somanuals.com. All Manuals Search And Download.
D-11
MetroSelect™
Beeper Options
*Normal Tone
318575
Optional Tone 1
318565
Optional Tone 2
318555
Optional Tone 3
318545
Optional Tone 4
318535
Optional Tone 5
318525
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Optional Tone 6
No Beep
318515
318505
Beep Twice on Supplements
*Beep Once on Supplements
118406
118416
Enable Fast Beep
*Disable Fast Beep
118414
118404
Download from Www.Somanuals.com. DA-ll1M2anuals Search And Download.
D-13
MetroSelect™
*Ignore BEL
Command
Beep on BEL Command
118417
118407
The scanner beeps when it receives
a BEL character from the host. If a
number is sent within 200 msecs
before the BEL character, the
scanner will beep that number of
times.
*Disable Light Pen Toggle During
Beep
Enable Light Pen Toggle During
Beep
116913
116903
Whenenabled,thescannerbeepsandtog-
gles thelightpendatalineonasuccessful
decode. Thisdrives agoodreadindicator.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Data Transmission Delays
Use these codes to select the amount of delay between sending data characters and “Bar code” Records from the scan-
ner to the host. This helps prevent the scanner from overflowing host input buffers.
Intercharacter Delay Options
10 msec Intercharacter Delay
8188100
*1 msec Intercharacter Delay
818810
25 msec Intercharacter Delay
~Variable msec Intercharacter Delay
918800
8188250
Scanthisbarcodeandasequenceofcode
bytes in Section M to set the delay
betweencharacterssenttothehost
system. (Range from 1 to 255 msecs.)
RefertotheMultiCodeMethodonpageiii.
D-14
Download from Www.Somanuals.com. All Manuals Search And Download.
D-15
MetroSelect™
No Intercharacter Delay
818800
Inter-Record Delay
~Variable Inter-Record Delay
919300
*Leave Laser On During
Inter-Record Delay
Turn Off Laser During Inter-
Record Delay
119317
119307
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Communication Timeout Options
Enable Communications
Time Outs
*Disable Communications
118412
118402
Beep After
Transmit
*Beep Before
Transmit
118413
118403
Scanner will beep after each label is trans-
mitted.
Scanner will beep after each label is trans-
mitted.
~Variable Communications Time Out
919100
*Default Communications Time Out
(2 secs)
8191400
D-16
Download from Www.Somanuals.com. All Manuals Search And Download.
D-17
MetroSelect™
Short Communications Time Out
(1 secs)
Long Communications Time Out
(4 secs)
8191200
8191800
Three Beeps on
Time Out
*No Beeps on
Time Out
118410
118400
*No Razzberry Tone on Time
Out
Razzberry Tone on Time Out
118411
118401
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Host Scanner Commands
Enable “D/E” Disable Command
118115
*Disable “D/E” Disable
118105
When this option is chosen, the scan-
ner will disable scanning after it
receives an ASCII “D” from the host
device. It will enable scanning when
it receives an ASCII “E.”
Donot monitorD/E commands.
Enable Z/R Type D/E Simulation
118211
*No “Z/R” Type “D/E”
Simulation
118201
When this option is chosen, the
scanner will disable scanning after it
receives an ASCII “Z” from the host
device. It will enable scanning when it
receives an ASCII “R.”
Do not monitorZ/R commands.
D-18
Download from Www.Somanuals.com. All Manuals Search And Download.
D-19
MetroSelect™
Enable “F/L” Laser Command
118014
*Disable “F/L” Laser Command
118004
When enabled, the scanner will turn
off the laser after the scanner
receives an ASCII “F” character. The
laser will turn on after it receives an
ASCII “L” character.
Do not monitor “F/L” commands.
Motor On/Off Using
M/O Commands
*Disable M/O
Commands
118213
118203
When enabled, the motor will turn on
after the scanner receives an ASCII
“M” character. The scanner will turn
off the laser and motor after it
receives an ASCII “O” character.
For use with omnidirectional
scanners only.
Do not monitor M/ O commands.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Use DTRScan Disable
*Do not use DTRScan Disable
118115
118105
Do not monitor the DTR input.
When enabled, the scanner will
monitor the DTR input to determine if
scanning should be allowed. A +12V
“active” level enables decoding.
A -12V “inactive” level disables
decoding.
Download from Www.Somanuals.com. DA-ll2M0anuals Search And Download.
D-21
MetroSelect™
Activate on DC2 Character
*Do Not Activate on DC2
Character
118110
118100
Transmit “NO READ” if DC2
Activated
Do Not Transmit “NO READ” if
DC2 Activated
118111
118101
No Green LED During
“NO READ” Xmit
*Green LED During “NOREAD”
Xmit
118311
118301
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Power Save Modes
Always Power Save Mode
118617
No Power Save
Mode
818600
Enters power save mode immediately
after power-up and after each bar
code scanned. For use with
Omnidirectional scanners only.
The scanner will never enter power
save mode. For use with
Omnidirectional scanners only.
Power Save in
2 Minutes
Power Save Mode in
1 Minute
118610
818620
Enters power save mode when the scanner
remains idle for 1 minute. For use with
Omnidirectional scanners only.
Enters power save mode if the scanner
remains idle for 2 minutes. For use
with Omnidirectional scanners
only.
D-22
Download from Www.Somanuals.com. All Manuals Search And Download.
D-23
MetroSelect™
Power Save in
5 Minutes
Power Save in
10 Minutes
8186100
818650
Enterspowersavemodeifthescannerremains
idle for 10 minutes. For use with
Omnidirectional scanners only.
Enters power save mode if the scanner
remains idle for 5 minutes. For use
with Omnidirectional scanners
only.
Power Save in
30 Minutes
Power Save in
20 Minutes
8186200
8186300
Enterspowersavemodeifthescanner
remainsidle for30minutes. For use
with Omnidirectional scanners
Enterspowersavemodeifthe scanner
remainsidlefor20minutes. For use
with Omnidirectional scanners
only.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Miscellaneous Features
Enable Japan Mode
118112
*Disable Japan Mode
118102
Download from Www.Somanuals.com. DAl-l2M4anuals Search And Download.
D-25
MetroSelect™
Test Modes
Scanability ON
*Scanability OFF
118017
118007
This option enters scanability test mode. Do
not enable unless instructed by a
Metrologic representative.
Scan Count Mode ON
118016
*Scan Count Mode OFF
118006
When enabled, the scanner willenter scan
count test mode and the scanner’s
firmwaer numberwilltransmit tothehost.
Do not enable unless instructed by a
Metrologic representative.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section E
Prefixes/ Suffixes
User Configurable Prefixes, All Data
User Configurable ID Characters, Code Specific
Standard Prefix Characters
E-1
E-3
E-8
Standard Suffix Characters
E-13
E-15
E-16
E-19
Longitudinal Redundancy Check (LRC)
User Configurable Suffixes, All Data
Special Formats
E
Download from Www.Somanuals.com. All Manuals Search And Download.
E-1
MetroSelect™
User Configurable Prefixes, All Data
Note: Scan “Enter configuration mode” code before trying to set this feature. Please refer to
MultiCode Method pn page iii.
~Configurable Prefix
Character #1
~Configurable Prefix
Character #2
903500
903600
When this option is chosen, a prefix
ID can be added and assigned for
data transmission. Use this code with
a 3 code byte sequence from
Section M that represents the
desired character.
Assigns a second configurable prefix
character.
~Configurable Prefix Character
~Configurable Prefix
Character #3
#4
903700
903800
Assigns a fourth configurable prefix
character.
Assignsathirdconfigurableprefixcharacter.
~Configurable Prefix
Character #5
~Configurable Prefix
Character #6
904000
903900
Assignsasixthconfigurableprefixcharacter.
Assignsafifth configurable prefixcharacter.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
~Configurable Prefix
Character #7
~Configurable Prefix
Character #8
904100
904200
Assigns a seventh configurable prefix
character.
Assigns an eighth configurable prefix
character.
~Configurable Prefix
Character #10
~Configurable Prefix
Character #9
904300
904400
Assignsatenthconfigurableprefix
characte.r
Assignsaninthconfigurableprefix
characte.r
*Clear All User Configurable
Prefixes
999985
Download from Www.Somanuals.com. All Manuals SE-e2arch And Download.
E-3
MetroSelect™
User Configurable ID Characters, Code Specific
*Use Configurable Code ID Bytes
as Prefixes
Use Configurable Code ID Bytes
as Suffixes
105507
105517
User configured, codespecific IDbytes
are transmitted after the data. If
using suffixes, user configured
prefixes can not be used.
User configured, code specific ID bytes
are transmitted before the data. If
using prefixes, user configured
suffixes can not be used.
Identifiers Characters
Configurable
UPC-A ID
Configurable
UPC-E ID
905600
905700
While using the MultiCode Method, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
While using the MultiCode Method, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Configurable
EAN-8 ID
Configurable
EAN-13 ID
905800
905900
While inusing theMultiCodeMethod, scan
this bar code followed by the 3code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
While inusing theMultiCodeMethod, scan
this bar code followed by the 3code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Configurable
Code 128 ID
Configurable
Code 39 ID
906000
906100
While inusingthe MultiCodeMethod, scan
this bar code followed by the 3code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
While inusingtheMultiCodeMethod, scan
this bar code followedby the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Download from Www.Somanuals.com. All ManualsES-e4arch And Download.
E-5
MetroSelect™
Configurable
Code 93 ID
Configurable
Code 11 ID
906300
906400
Whileinusingthe MultiCode Method, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Whileinusingthe MultiCode Method, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Configurable
Telepen ID
Configurable
TRI-OPTIC ID
906200
907200
While inusing theMultiCodeMethod, scan
this bar code followed by the 3code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
While inusing theMultiCodeMethod, scan
this bar code followed by the 3code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Configurable
Interleaved 2 of 5 ID
Configurable
Standard 2 of 5 ID
907100
906700
While inusingthe MultiCode Method, scan
thisbar codefollowed by the 3 codebyte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Whileinusingthe MultiCode Method, scan
thisbar codefollowed by the 3 codebyte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Configurable
Configurable
Airline 2 of 5 ID
Matrix 2 of 5 ID
906800
906900
Whileinusing theMultiCodeMethod, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Whileinusing theMultiCodeMethod, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
E-7
MetroSelect™
Configurable
UK Plessey ID
Configurable
MSI Plessey ID
906500
907000
While inusingthe MultiCode Method, scan
thisbar codefollowed by the 3 codebyte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Whileinusingthe MultiCode Method, scan
thisbar codefollowed by the 3 codebyte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
*Clear all Configurable Code
Specific ID’s
Configurable
Codabar ID
906600
999983
While inusingtheMultiCodeMethod, scan
this bar code followed by the 3 code byte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
While inusingtheMultiCodeMethod, scan
this bar code followed by the 3 codebyte
bar codes in Section M that represent a
unique ID character to be associated with
this bar code type. Please refer to
MultiCodeMethodonpageiii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Standard Prefix Characters
Enable STX Prefix
116615
*Disable STX Prefix
116605
Will not transmit a Start of TeXt
(ASCII 02H) before each bar code.
When enabled, the scanner will trans-
mit a Start of TeXt (ASCII 02H)
before each bar code.
Enable Rochford-Thomson Mode
105513
*Disable Rochford-Thomson Mode
105503
*Disable AIM ID Characters
107905
Enable AIM ID Characters
107915
The scanner will transmit AIM
symbology identifiers. Some scan-
ners may not support this feature
The scanner will not transmit AIM
symbology identifiers.
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
E-9
MetroSelect™
Enable UPC Prefix ID
*Disable UPCPrefix ID
116617
116607
Do not send prefix ID Characters with
UPC/EAN codes.
When enabled, the scanner will
transmit a prefix before any UPC/EAN
bar code. The prefixes are A (UPC-A),
E0 (UPC-E), F (EAN-13), and
FF (EAN-8).
Enable NCR Prefix ID
107911
*Disable NCR Prefix ID
107901
When enabled, the scanner will transmit a
prefix before the following code types.
The prefixes are as follows:
A (UPC-A)
E0 (UPC-E)
FF (EAN-8)
F (EAN 13)
B1 (Code 39)
B2 (ITF)
B3 (Code 128 and other codes)
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable Nixdorf ID Characters
107917
*Disable Nixdorf ID Characters
107907
This bar code will not transmit
Siemens/Nixdofrcode identifiers.
When enabled, this option transmits
code identifiers before each bar code
for many Siemens/Nixdorf registers.
*Disable SANYO ID Characters
107906
Enable SANYO ID Characters
107916
Transmit Sanyo ID Characters.
Do not transmit Sanyo ID Characters.
Download from Www.Somanuals.com. All ManualsES-e1a0rch And Download.
E-11
MetroSelect™
*Disable Manufacturer ID Prefix
Enable Manufacturer ID Prefix
105512
105502
Transmits “METROLOGIC” before all bar
code data to identify the scanner as a
Metrologicscanner.
Will not transmit the identification
string.
*Disable “C” Prefix
105501
Enable “C” Prefix
105511
Enable “$” Prefix ID for
UPC/EAN
*Disable “$” Prefix ID for
UPC/EAN
105510
105500
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable Tab Prefix
*Disable Tab Prefix
116611
116601
Will not transmit a TAB.
The Scanner will transmit a TAB
(ASCII 09H) before each bar code.
*Disable SNI Beetle Mode
116101
Enable SNI Beetle Mode
116111
Enable Cipher 1021 IDs
116113
*Disable Cipher 1021 IDs
116103
Download from Www.Somanuals.com. All ManualsES-1ea2rch And Download.
E-13
MetroSelect™
Standard Suffix Characters
Disable CR Suffix
*Enable CR Suffix
116613
116603
The scanner will not transmit a
Carriage Return after each bar
code.
When enabled, the scanner transmits a
Carriage Return after each bar code.
*Enable LF Suffix
116612
Disable LF Suffix
116602
When enabled, the scanner transmits
a Line Feed after each bar code.
Note: Disabled when keyboard
wedge defaults are loaded.
The scanner will not transmit a Line
Feed after each bar code.
Enable Tab Suffix
116610
*Disable Tab Suffix
116600
When enabled, the scanner will
transmit a TAB (ASCII 09H) after
each bar code.
Will not transmit TAB (ASCII 09H)
after each bar code.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable ETX Suffix
*Disable ETX Suffix
116614
116604
When enabled, the scanner will
transmit End of TeXt (ASCII 03H)
after the bar code data.
When disabled, the scanner will not
transmit End of TeXt (ASCII 03H).
Enable UPC Suffix ID
116616
*Disable UPC Suffix ID
116606
When enabled, the scanner will
transmit a suffix after any UPC/EAN
bar code. The suffixes are A (UPC-
A), E (UPC-E), F (EAN-13) and
F (EAN-8).
Will not transmit a suffix after
UPC/EAN bar codes.
Download from Www.Somanuals.com. All ManualsES-1ea4rch And Download.
E-15
MetroSelect™
Longitudinal Redundancy Check (LRC)
*Disable Transmit of LRC
Calculation
Enable Transmit of LRC
Calculation
107811
107801
Will not output an LRC (check
character) after the bar code.
With this option, the scanner outputs
an LRC check character after the bar
code.
Start LRC on
Second Byte
*Start LRC on
First Byte
107810
107800
Thescannerwillcalculate the LRCcheck
digit startingwith the firstcharacter
ThescannerwillcalculatetheLRCcheck
digit starting with thesecond character.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
User Configurable Suffixes, All Data
Note: Scan “Enter configuration mode” code before trying to set this feature. Refer to
MultiCode Method on page iii.
~Configurable Suffix
Character #1
~Configurable Suffix
Character #2
904500
904600
When chosen, a suffix ID can be added
and assigned for data transmission.
Use this code with a 3 code byte
sequence from Section M that
Assignsasecondconfigurable suffix
characte.r
represents the desired character.
~Configurable Suffix
Character #4
~Configurable Suffix
Character #3
904700
904800
Assignsafourthconfigurablesuffix
characte.r
Assignsathirdconfigurablesuffix
characte.r
E-16
Download from Www.Somanuals.com. All Manuals Search And Download.
E-17
MetroSelect™
~Configurable Suffix
Character #5
~Configurable Suffix
Character #6
904900
905000
Assignsafifthconfigurablesuffix character.
Assignsasixthconfigurablesuffixcharacter.
~Configurable Suffix
Character #8
~Configurable Suffix
Character #7
905100
905200
Assignsaseventhconfigurablesuffix
characte.r
Assignsaneighthconfigurablesuffix
characte.r
~Configurable Suffix
Character #10
~Configurable Suffix
Character #9
905300
905400
Assignsatenthconfigurablesuffixcharacter.
Assignsaninth configurable suffixcharacter.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
*Clear All User Configurable
Suffixes
999984
E-18
Download from Www.Somanuals.com. All Manuals Search And Download.
E-19
MetroSelect™
Special Formats
*Disable SINEKO Mode
Enable SINEKO
Mode
107914
107904
*Disable Newcode Formatting
Mode A
Enable Newcode Formatting
Mode A
116711
116701
*Disable Newcode Formatting
Mode B
Enable Newcode Formatting
Mode B
116710
116700
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section F
Code Formatting
UPC-EAN Formatting
Codabar Formatting
Code 39 Formatting
Code 11
F-1
F-5
F-6
F-7
F-7
F-8
F-9
Telepen
Plessey
2 of 5 Code Formatting
Download from Www.Somanuals.com. All Manuals Search AndFDownload.
F-1
MetroSelect™
UPC/ EAN Formatting
*Transmit UPC-A
Check Digit
Do Not Transmit UPC-A
Check Digit
116617
116607
Transmit UPC-E
Check Digit
*Do Not Transmit UPC-E
Check Digit
107516
107506
Expand UPC-E to
12 Digits
*Do Not Expand UPC-E to
12 Digits
107515
107505
Expand UPC-E bar codes to the 12 digit
equivalent, UPC-A bar codes.
Do not expand UPC-E to the 12 digit
equivalent, UPC-A bar code.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Convert UPC-A to EAN-13
107514
*Do Not Convert UPC-A to EAN-13
107504
With this option, the scanner converts
UPC-A to EAN-13 by transmitting a lead-
ing zero before the bar code.
With this option, the scanner will not
convert UPC-A to EAN-13.
Transmit Lead Zero on UPC-E
107513
Do Not Transmit Lead Zero on
UPC-E
107503
This option will not transmit a zero
before each UPC-E bar code.
When chosen, this option will transmit
a zero before each UPC-E bar code
Convert EAN-8 to
EAN-13
*Do Not Convert
EAN-8 to EAN-13
107512
107502
When chosen, the scanner will trans-
mit five zeros before the bar code to
convert EAN-8 to Ean-13.
When chosen, the scanner will not
convert EAN-8 to Ean-13.
F-2
Download from Www.Somanuals.com. All Manuals Search And Download.
F-3
MetroSelect™
Do Not Transmit UPC-A
Number System
*Transmit UPC-A
Number System
107511
107501
Metrologic strongly discourages using
this feature. Duplicate numbers may
result in the database.
*Transmit UPC-A MFR#
Do Not Transmit
UPC-A MFR#
107611
107601
*Transmit UPC-A ITEM#
Do Not Transmit
UPC-A ITEM#
107610
107600
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Do Not Transmit EAN-8
Check Digit
*Transmit EAN-8
Check Digit
107910
107900
Do Not Transmit
*Transmit EAN-13 Check Digit
EAN-13 Check Digit
107912
107902
Scanner will not transmit EAN-13
Check Digit.
Scanner will transmit EAN-13
Check Digit.
Download from Www.Somanuals.com. All Manuals Search AnFd-D4ownload.
F-5
MetroSelect™
Codabar Formatting
*Do Not Transmit Codabar
Start/Stop
Transmit Codabar Start/Stop
Characters
107717
107707
Will not transmit Codabar’s start/stop
characters before and after each bar
code.
Transmits Codabar’s start/stop
characters before and after each
bar code.
Enable CLSI Editing
107716
*Do Not Enable
CLSI Editing
107706
Works only with 14 digit Codabar type
lengths. This option will perform CLSI
type editing before the information is
transmitted to the host.
This optionwill notperform CLSI
type editing before the information is
transmitted to thehost.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Code 39 Formatting
Transmit Mod 43 Check
Digit On Code 39
*Do Not Transmit Mod 43 Check
Digit On Code 39
107715
107705
ThisoptionwillnottransmitCode39’sMod
43checkcharacter.
This feature works in conjunction with
Mod43CheckonCode 39optionin
sectionA. Both must be enabled for this
featuretowork.
Transmit Code 39
Stop/Start Characters
*Do Not Transmit Code 39
107700
107710
When chosen, the scanner transmits
Code 39’s start and stop characters
before and after each bar code.
When chosen, the scanner will not
transmit Code 39’s start and stop
characters before and after each bar
code.
F-6
Download from Www.Somanuals.com. All Manuals Search And Download.
F-7
MetroSelect™
Code 11
*Do Not Transmit Code 11
Check Digit
Transmit Code 11 Check Digit
107713
107703
This bar code will transmit Code 11
check characters when used with
Enabled Code 11 in section A.
This bar code will not transmit Code
11check characters.
Telepen
*Disable Convert
Telepen ^L to E
Enable Convert
Telepen ^L to E
107814
107804
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Plessey
Transmit UK Plessey Check Digit
107816
*Do Not Transmit UK Plessey
Check Digit
107806
The scanner will transmit UK
Plessey CheckDigitcharacters and
must beused with the UK Plessey option.
WillnottransmitUKPlesseyCheck
Digitcharacters.
Disable UK Plessey
Special Format
Enable UK Plessey
Special Format
107815
107805
* Do Not Transmit MSI Plessey
Check Digit
Transmit MSI Plessey
Check Digit
107711
107701
This option works in conjunction with
one or both of the Enabled MSI Plessey
Mod options in Section A.
The scanner will not transit MSI
Plessey’s check digit characters.
F-8
Download from Www.Somanuals.com. All Manuals Search And Download.
F-9
MetroSelect™
2 of 5 Code Formatting
*Do not Transmit Mod 10 Check
Digit on ITF
Transmit Mod 10 Check Digit
on ITF
107714
107704
The scanner will nottransmit Interleaved
2 of 5 (ITF) Mod 10 check character.
Works in conjunction with Mod 10 check
on ITF. Both must be enable for this fea-
ture to work.
With this option, the scanner transmits
Interleaved 2 of 5 (ITF) Mod 10 check
characte.r
*Do Not Transmit Matrix 2 of
5 Check Digit
Transmit Matrix 2 of 5
Check Digit
107812
107802
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section G
RS-232
Enable RS-232
G-1
G-2
G-3
G-5
G-6
G-9
G-11
Parity Features
BAUD Rate Features
Data/Stop Bit Features
Hardware Handshaking
Software Handshaking
Miscellaneous
G
Download from Www.Somanuals.com. All Manuals Search And Download.
G-1
MetroSelect™
*Enable RS-232 Mode
415554
When enabled the scanner will
work with RS-232 +/-12V serial
output.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Parity Features
A parity bit is an extra data bit used to help catch data transmission errors.
The scanner’s parity must match the host’s parity.
No Parity
316045
Odd Parity
316005
*Space Parity
316015
Select Odd Parity to set the
parity bit to either a 1 or a 0 to
ensure an odd number of bits are
1’s.
Select Space Parity to set the
parity bit always 0.
Even Parity
316025
Mark Parity
316035
Select Mark Parity to set the parity bit
always 1.
SelectEven Paritytoset the parity bitto
either a 1 or0 to ensure an evennum-
ber of bits are 1’s.
G-2
Download from Www.Somanuals.com. All Manuals Search And Download.
G-3
MetroSelect™
BAUD Rate
A “BAUD” or “BAUD Rate” is the speed at which data is transmitted. Select a BAUD for the scanner that matches
the host device.
57600 BAUD Rate
115200 BAUD Rate
4158100
415890
Not supported on the
MS9500 Voyager.™
Not supported on the
MS9500 Voyager.™
19200 BAUD Rate
38400 BAUD Rate
415880
415870
14400 BAUD Rate
*9600 BAUD Rate
415860
415850
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
4800 BAUD Rate
2400 BAUD Rate
415840
415830
600 BAUD Rate
1200 BAUD Rate
415820
415810
300 BAUD Rate
415800
Download from Www.Somanuals.com. All Manuals Search And DownloaGd.-4
G-5
MetroSelect™
Data/ Stop Bits
*7 Data Bits
8 Data Bits
116013
116003
Number of data bits transmitted for
each character.
*2 Stop Bits
1 Stop Bit
116014
116004
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Hardware Handshaking
*Disable RTS/CTS Handshaking
115806
Enable RTS/CTS Handshaking
115816
OutputaRequestToSend
DonotuseRTS/CTShandshaking.
(RTS) signaland wait for a Clear To Send
(CTS)signalbeforetransmittingdata.
Message RTS/CTS
115805
*Character RTS/CTS
115815
Activate RTSbefore sendingthefirstchar-
acterandleaveitactiveuntilafterthelast
characterhasbeentransmitted.
Activate/Deactivate RTS signal for each
characte.r
Invert RTS Polarity (RSV1)
124510
*Standard RTS Polarity
124500
+12v=Inactive
-12v=Active
UsestandardRTSpolarity
-12v=Inactive
+12v=Active
Download from Www.Somanuals.com. All Manuals Search And DownloaGd.-6
G-7
MetroSelect™
Invert CTS Polarity (RSV2)
124511
*Standard CTS Polarity
124501
-12v = Inactive, do not send
+12v = Active, OK to send
+12v = Inactive, do not send
-12v = Active, OK to send
Activate RTS,
Do Not wait for CTS (RSV3)
*Activate RTS, Wait for CTS
124502
124512
Wait for CTSafter activating RTS.
Activate RTS for transmission but, do
not wait for CTS to send.
*Do Not Test for CTS Present
Before RTS
Test CTS Not Present
Before RTS (RSV4)
124513
124503
Do not activate RTS if CTS is already
present.
Activate RTS without testingif CTS is
already active.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable DTR Support
*Disable DTR Support
115817
115807
When enabled the scanner will stop
scanning when the Data Terminal Ready
(DTR) signal goes inactive.
Enable RTS Counter Toggle
115915
*Disable RTS Counter Toggle
115905
The scanner will toggle the RTS line on a
gooddecode.
G-8
Download from Www.Somanuals.com. All Manuals Search And Download.
G-9
MetroSelect™
Software Handshaking
Enable XON/XOFF Handshaking
115914
*Disable XON/XOFF Handshaking
115904
When enabled, the scanner will stop
transmission whenever an XOFF
(ASCII 13H) is received. Transmission
will resume after an XON(ASCII 11H) is
received.
Thescanner will not test for XON/XOFF.
*Disable ACK/NAK
115903
Enable ACK/NAK
115913
After transmitting data, wait for an ACK
(06H)or a NAK(15H)responsefromthe
host. If ACK is received, complete the
communications cycle and look for more
bar codes. IF NAK is received, retransmit
the last set of bar code data and wait for
ACK/NAK again.
Do not support ACK/NAK handshaking.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
*Ignore BEL/CAN in ACK/NAK
115901
Support BEL/CAN in ACK/NAK
115911
When BEL (07H) is received, the
scanner beeps 3 times and exits the
communicationsloop. IfaCAN (18H)is
received, then the scanner will exit the
communications loop, silently.
Ignore BEL/CAN characters in
communication loop.
Enable 5 Retries on ACK/NAK
Time Out
*Disable 5 Retries on ACK/NAK
Time Out
118013
118003
Allow up to 5 NAK retransmissions of
the data before dropping out of the
communications loop.
Donot limit retransmission to 5NAK
cycles.
G-10
Download from Www.Somanuals.com. All Manuals Search And Download.
G-11
MetroSelect™
Miscellaneous
*Disable French PC Term
Enable French PC Term
116110
116100
DonottransmitinFrenchPCTermmode.
Whenenabled,thescannertransmitsPCtype
make/berak scan codes instead of ASCII
data characters. The scan codes match a
WYSEFrenchPC TermTerminalEmulation.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section H
Keyboard
Enable Keyboard Emulations
H-1
H-2
H-4
H-5
H-8
H-9
Country/Scan Code Table Selects
Keyboard/System Type
Special Keyboard Features
InterScan Code Delays
Control Sets
H
Download from Www.Somanuals.com. All Manuals Search And Download.
H-1
MetroSelect™
Enable Keyboard Emulation
Load Keyboard Wedge Defaults
999994
Loads default settings for keyboard wedge
mode.
Enable Stand-Alone Keyboard
Emulation
*Enable Keyboard Wedge
Emulation
5155153
415574
Use this with an external keyboard.
Transmit in wedge mode to allow stan-
dard PC Keyboards to communicate
when no bar code data is available.
Usethiswithspecialstand-alonemodelsthat
are not cabled for an external keyboard.
Scanthisbarcode toenabletheStand-Alone
Mode. The scanner will send keyboard
“power on” information and configure
hardware to simulate a constant keyboard
connection.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Country/ Scan Code Table Selects
Switzerland Keyboard
*USA Keyboard
416240
416280
Enable USA Keyboard.
EnableSwiss Keyboard.
Spain Keyboard
416250
Italy Keyboard
416240
Enable Italian Keyboard.
Enable Spanish Keyboard.
Germany Keyboard
416230
France Keyboard
416220
Enable French Keyboard.
Enable German Keyboard.
H-2
Download from Www.Somanuals.com. All Manuals Search And Download.
H-3
MetroSelect™
UK Keyboard
Belgium Keyboard
416210
416200
Enable UK Keyboard.
Enable Belgium Keyboard.
Japanese Keyboard
IBM 4700 Financial Keyboard
416270
4162100
Enable Japanese Keyboard.
Enable IBM 4700 Financial
Keyboard.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Keyboard/ System Type
*AT Keyboard
216215
If using an AT computer, scan the
above. (Includes IBM PS/2 and
compatible models 50, 55, 60, 80)
PS/2 Keyboard
216225
XT Keyboard
216205
Scan the above for PS/ 2 computer.
(Includes IBM PC and compatible models
30, 70, 8556)
If usinganXTcomputer, scantheabove.
H-4
Download from Www.Somanuals.com. All Manuals Search And Download.
H-5
MetroSelect™
Special Keyboard Features
Transmit Make Code Only
116311
*Transmit Make/Break Code
116301
Do not scan unless instructed by a
Metrologicrepresentative.
Do not scan unless instructed by a
Metrologic representative.
Do Not Transmit F0H Break Code
116300
*Transmit F0H Break Code
116310
The scanner will not transmit the F0H
in the break-code sequence.
The scanner will transmit the F0H
in the break-code sequence.
Transmit Cleanup Bit
116315
*Do Not Transmit Cleanup Bit
116305
Use for certainNEC computers.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Enable Alt Mode
*Disable Alt Mode
116217
116207
Caution: If host software application
uses the right Alt key as a “Hot” key.
Alt mode must be disabled.
When enabled, the scanner will
duplicate this keyboard sequence:
Hold down ALT key: Type decimal number that
corresponds to the appropriate character.
Enable Auto Detect Mode
(AT/PS2)
*Disable Auto Detect Mode
(AT/PS2)
116214
116204
Automatically detects caps lock status.
When disabled, theCapsLockfeature is
notsupported.
Enable Caps Lock (XT)
116315
*Disable Caps Lock (XT)
116305
When disabled, theCapsLockfeature
isnotsupported.
H-6
Download from Www.Somanuals.com. All Manuals Search And Download.
H-7
MetroSelect™
Send Numbers as Keypad Data
116316
*Send Numbers as Normal Data
116306
Whenenabled, alldatais sentasif ithas been
enteredonakeypad.
Enable Reserved Feature
116410
*Disable Reserved Feature
116400
Use Extended ASCII Characters
As Extended ASCII
*Use Extended ASCII To Send
Extended Key Codes
116303
116313
Use extended ASCII characters to
send PC keyboard keys such as F1,
F2, etc...See section M for details.
Transmit extended ASCII codes via
ALT Mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Message KB Inhibit
116314
*Character KBInhibit
116304
InterScan Code Delays
*InterScan Code Delay 800
Microseconds
InterScan Code Delay 7.5 msec
8165750
816580
The time specifiedrepresentstheamount
of time between individual 9 bit-scan
codes. This parameter may need to be
adjusted for operation with certain PC
keyboadr BIOS.
The time specifiedrepresentstheamount
of time between individual 9 bit-scan
codes. This parameter may need to be
adjusted for operation with certain PC
keyboadr BIOS.
~Variable InterScan Code
Delay msec
InterScan Code Delay
15 msec
81651500
916500
RefertoMulti-CodeMethodonpageiii.
Thetimespecifiedrepresentstheamount oftime
betweenindividual9bit-scancodes. Thisparam-
eter mayneed tobe adjusted for operation with
certainPCkeyboardBIOS.
H-8
Download from Www.Somanuals.com. All Manuals Search And Download.
H-9
MetroSelect™
Control Sets
In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and
many other “extended” keys on an IBMcompatible keyboard do not translate to ASCII characters. One method of
“bar coding” the extended keys is to substitute the extended key codes when a specific ASCIIcontrol character is
found in the bar code stream. The Control Sets are specific translations of the ASCII (HEX) set.
Control Set #1
Disable Control Set #1
Enable Control Set #1
416484
416404
ASCII (HEX)
Extended Key
Numeric Keypad
ASCII Control
00H
01H
02H
03H
04H
05H
06H
07H
08H
09H
Null
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
Num Lock
Down
Numeric Keypad-
Insert
Delete
System Request
➝
Tab
TAB
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Control Set #1 Continued
Extended Key
Caps Lock
ASCII (HEX)
ASCII Control
0AH
0BH
0CH
0DH
0EH
0FH
10H
11H
12H
13H
14H
15H
16H
17H
18H
19H
1AH
1BH
1CH
1DH
1EH
1FH
LF
VT
Shift Tab
Alt
FF
Enter
Control
Up Arrow
F1
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
F2
F3
F4
F5
F6
F7
F8
F9
F10
Home
Esc
Page UP
Page Down
Print Screen
End
GS
RS
US
H-10 Download from Www.Somanuals.com. All Manuals Search And Download.
H-11
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section I
OCIA
OCIA
I-1
I-1
I-1
I-1
I-1
I-1
Load OCIA Defaults
DTS/Nixdorf
DTS/Siemens
NCR-S
NCR-F
DownloIad from Www.Somanuals.com. All Manuals Search And Download.
I-1
MetroSelect™
Enable OCIA Mode
Load OCIA Defaults
999993
415544
Select this option if communications
requires OCIA (Optically Coupled
Interface Adapter). This serial inter-
face is clocked by the host.
*Enable DTS/Nixdorf
Enable DTS/Siemens
217706
217716
Enable NCR-S
217736
Enable NCR-F
217726
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section J
Light Pen Parameters
Enable Light Pen Mode
Spaces/Bar High
J-1
J-1
J-1
J-2
J-2
J-2
J-2
J-3
Transmit as Scanned/Code 39
Poll Light Pen Source
Light Pen Extra Toggle
10x Narrow Element Border
50x Narrow Element Border
Set Narrow Element Width
Download from WJww.Somanuals.com. All Manuals Search And Download.
J-1
MetroSelect™
Enable Light Pen Mode
415524
Select this option if the scanner will be
used in place of a light pen. It provides
light pen emulation of each bar code
scanned.
Spaces High
116907
*Bars High
116917
Transmit Code 39
*Transmit as Scanned
116906
116916
All bar codes will be decoded then
transmitted as code 39 bar codes.
All bar codes will be decoded and
transmitted in that symbology.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Poll Light
Pen Source
*Do Not Poll Light
Pen Source
116915
116905
When chosen, the scanner will not wait
foranactivesource voltagebefore
transmittingdata.
When chosen, the scanner waits for
an active source voltage before
transmitting data.
Enable Light Pen Extra Toggle
116911
*Disable Light Pen Extra Toggle
116901
When enabled, the scanner beeps and tog-
gles the light pen data line with an extra
datapulsetoconditionthedecoder.
10x Narrow Element Border
116912
*50x Narrow Element Border
116902
This bar code allows the transmission of
LightPen/Wandemulationusinga
50xborder.
This bar code allows the transmission of
Light Pen/Wand emulation using a 10x
borde.r
Download from WJ-2ww.Somanuals.com. All Manuals Search And Download.
J-3
MetroSelect™
Set Narrow Element Width
*1 ms Narrow
Element Width
60 µs Narrow
Element Width
81681630
8168100
Thistransmitsat60µsNarrowelementwidth.
This option allows the transmission of
Light/Pen Wand emulation at 1ms
Narrow Element width.
100 µs Narrow
Element Width
500 µs Narrow Element Width
8168820
8168160
This transmits at 100 µs Narrow element
width.
This transmits at 500 µs Narrow element
width.
~Variable Narrow Element Width
916800
Sets the minimum x-dimension in 6 µs
increments. Scanthiscodefollowedbya3
digit code byte sequence found in Section
M. RefertoMultiCodeMethodonpageiii.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section K
IBM 46xx Configuration
IBM Port
K-1
K-2
IBM Reserved Codes
Download from Www.SomanKuals.com. All Manuals Search And Download.
K-1
MetroSelect™
Load 46xx
IBM Defaults
Enable IBM 46xx Communication
415504
999995
Load default format
Select this option for IBM 46XX
SIOC/RS485 communications. Not all
scannerssupportthisinterface.Thecorrect
interfaceboardis required.
settings for the IBM 46xx systems.
IBM Port
IBM Port 5B
IBM Port 17B
1520 HH Laser
3687-2 In Counter
317250
317260
IBM Port 9B
4500 CCD HH BCRI
317270
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
IBM Reserved Codes
IBM Reserved #2
IBM Reserved #1
317200
317210
IBM Reserved #4
IBM Reserved #3
317220
317230
IBM Reserved #5
317240
K-2
Download from Www.Somanuals.com. All Manuals Search And Download.
K-3
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section L
MS9500 Voyager™
Activation Range
L-1
L-2
L-3
L-4
CodeGate™ Status
Laser/Scan Modes
Same Symbol Time Outs
L
Download from Www.Somanuals.com. All Manuals Search And Download.
L-1
MetroSelect™
Activation Range
Use these bar codes to select infrared (IR) sensor activation range for sensing when objects are placed in the
scan field.
*Long Range in Stand
Short Range in Stand
118715
118705
Short Range out of Stand
*Long Range out of Stand
118711
118701
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
CodeGate™ Status
Use the following to control button functions.
CodeGate Active in the Stand
118707
*CodeGate Inactive in the Stand
118717
CodeGate Inactive Out of Stand
118703
*CodeGate Active Out of Stand
118713
Download from Www.Somanuals.comL.-A2ll Manuals Search And Download.
L-3
MetroSelect™
Laser/ Scan Modes
*Normal Scan
418304
Laser turns on after the IR senses a
bar code. The laser remains on for
approximately 3 to 10 seconds.
Blinky Scan
418324
Continuous Blinky Scan
418334
Laser turns on after the IR senses a
bar code. The laser will blink on/off
for approximately 60 seconds.
The laser blinks continuously. The IR
is inactive.
Custom (One Shot) Scan
418344
Laser turns on after the IR senses a
bar code. The laser will turn off
after a good decode.
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Same Symbol Time Outs
No Same Symbol
Time Out
1000 msec Same Symbol
Time Out
318910
818900
750 msec Same Symbol
Time Out
*875 msec Same Symbol
Time Out
318930
318920
625 msec Same Symbol
Time Out
500 msec Same Symbol
Time Out
318950
318940
Download from Www.Somanuals.comL.-A4ll Manuals Search And Download.
L-5
MetroSelect™
250 msec Same Symbol
Time Out
375 msec Same Symbol
Time Out
318970
318960
Infinite Same Symbol
Time Out
118917
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section M
Code Bytes
Code Byte Usage
Code Bytes 0-5
Code Bytes 6-9
Reserved Codes
M-1
M-2
M-3
M-4
M-5
M-6
M-11
Code Byte/Code Type Table
ASCII Reference Table
Extended Key Code Reference Table
M
Download from Www.Somanuals.com. All Manuals Search And Download.
M-1
MetroSelect™
Code Byte Usage
NOTE!
User Configurable Prefixes, Symbol Length and other features that use these Code Bytes for configura-
tion, require that the scanner be in Configuration Mode. Scan the Enter/Exit Configuration Mode bar
code before starting the configuration cycle. Single Code Configuration Mode does not work for these
multi-code sequences.
Example #1
User configurable prefix/suffix characters (section E) can be saved into the scanner by scanning the 3
digit decimal equivalent of the ASCII character into the appropriate character location with the code
byte bar codes.
Add an Asterisk (*) as a Prefix
1. Enter/Exit
(3 beeps)
2. Configurable Prefix #1 (1 beep)
3. Code Byte #0
4. Code Byte #4
5. Code Byte #2
6. Enter/Exit
(1 beep)
(2 beeps)
(3 beeps)
(3 beeps)
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Code Bytes 0-5
Code Byte 0
0
Code Byte 1
1
Code Byte 2
2
Code Byte 3
3
Code Byte 4
4
Code Byte 5
5
M-2
Download from Www.Somanuals.com. All Manuals Search And Download.
M-3
MetroSelect™
Code Bytes 6-9
Code Byte 7
Code Byte 6
6
7
Code Byte 8
8
Code Byte 9
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Reserved Codes
~Enable Reserved Code
999988
~Disable Reserved Code
999987
Contact Metrologic for information
about this feature.
M-4
Download from Www.Somanuals.com. All Manuals Search And Download.
M-5
MetroSelect™
Code Byte/ Code Type Table
Code Byte
Code Types
UPC-A
004
002
003
005
080
081
082
083
084
091
092
093
094
095
096
099
098
097
UPC-E
EAN-8
EAN-13
Code 39
Codabar
Interleaved 2 of 5
Code 128
Code 93
MSI Plessey
Code 11
Airline 2 of 5 (15 digits)
Matrix 2 of 5
Telepen
UK Plessey
TRI-OPTIC
Standard 2 of 5
Airline (13 digits)
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
ASCII Reference Table
Decimal Value/ Code Byte
Value
Control Keyboard
EQV
HEX Value
Character
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
000
@
A
B
C
D
E
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
F
G
H
I
HT
LF
J
VT
K
L
FF
CR
M
N
O
P
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Q
R
S
T
U
V
W
X
Y
Download from Www.Somanuals.com. All ManuMals-6Search And Download.
M-7
MetroSelect™
ASCII Reference Table
Control Keyboard
EQV
Decimal/ Code Byte Value
HEX Value
Character
Z
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
043
044
045
046
047
048
049
050
051
SUB
ESC
FS
GS
RS
US
SP
!
[
\
^
_
space, blank
“
#
$
%
&
‘
apostrophe
(
)
*
+
comma
minus
period
,
-
.
/
number zero
number one
0
1
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
ASCII Reference Table
Control Keyboard
EQV
Decimal/ Code Byte Value
HEX Value
Character
052
053
054
055
056
057
058
059
060
061
062
063
064
065
066
067
068
069
070
071
072
073
074
075
076
077
4
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
5
6
7
8
9
:
;
less than
greater than
shift P
<
=
>
?
@
A
B
C
D
E
F
G
H
I
letter I
J
K
L
M
M-8
Download from Www.Somanuals.com. All Manuals Search And Download.
M-9
MetroSelect™
ASCII Reference Table
Control Keyboard
EQV
Decimal/ Code Byte Value
HEX Value
Character
078
079
080
081
082
083
084
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
100
101
102
103
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
letter O
shift K
shift L
\
shift M
]
à, shift N
❧, shift O,
underscore
accent grave
^
_
‘
a
b
c
d
e
f
g
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
ASCII Reference Table
Control Keyboard
EQV
Decimal/ Code Byte Value
HEX Value
Character
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
h
i
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
I
vertical slash
alt mode
}
~
DEL
(alt mode)
delete, rubout
Download from Www.Somanuals.com. All ManuMals-1S0earch And Download.
M-11
MetroSelect™
Extended Key Code Reference Table
XT/ PS2 Scan Code
Prefix/ Suffix Value
Hex = Decimal
At Scan Code
Key
75H
72H
74H
6BH
70H
71H
6CH
69H
7DH
7AH
11H
14H
00H
00H
5AH
4AH
05H
06H
04H
0CH
03H
0BH
83H
0AH
01H
09H
80H = 128
81H = 129
82H = 130
83H = 131
84H = 132
85H = 133
86H = 134
87H = 135
88H = 136
89H = 137
8AH = 138
8BH = 139
8CH = 140
8DH = 141
8EH = 142
8FH = 143
90H = 144
91H = 145
92H = 146
93H = 147
94H = 148
95H = 149
96H = 150
97H = 151
98H = 152
99H = 153
48H
50H
4DH
4BH
52H
53H
47H
4FH
49H
51H
38H
1DH
00H
00H
1CH
35H
3BH
3CH
3DH
3EH
3FH
40H
41H
42H
43H
44H
➝
Insert
Delete
Home
End
Page Up
Page Down
Right Alt
Right Ctrl
Reserved
Reserved
Numeric Keypad Enter
Numeric Keypad /
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Extended Key Code Reference Table
Prefix/ Suffix Value
Hex = Decimal
XT/ PS2 Scan Code
At Scan Code
Key
57H
58H
4EH
4AH
37H
3AH
45H
38H
1DH
2AH
36H
9AH = 154
9BH = 155
9CH = 156
9DH = 157
9EH = 158
9FH = 159
A0H = 160
A1H = 161
A2H = 162
A3H = 163
A4H = 164
78H
07H
79H
7BH
7CH
58H
77H
11H
14H
12H
59H
F11
F12
Numeric +
Numeric -
Numeric *
Caps Lock
Num Lock
Left Alt
Left Ctrl
Left Shift
Right Shift
A5H = 165
A6H = 166
A7H = 167
A8H = 168
A9H = 169
AAH = 170
ABH = 171
ACH = 172
ADH = 173
AEH = 174
AFH = 175
Multiple
0DH
8DH
5AH
76H
11H
11H
14H
14H
11H
14H
Print Screen
Tab
OFH
8FH
1CH
01H
36H
B6H
1DH
9DH
36H
1DH
Shift Tab
Enter
ESC
Left ALT Make
Left ALT Break
Left CTRL Make
Left CTRL Break
* Left ALT + 1 character
* Left CRTL + 1 character
* Example
1st Configurable Prefix = 174
2nd Configurable Prefix = 065
Scanner will transmit <Left ALT Make> “A” <Left ALT Break>
M-12
Download from Www.Somanuals.com. All Manuals Search And Download.
M-13
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Section N
Miscellaneous Features
Custom Defaults
N-1
N-3
Serial Program Mode
Download from Www.Somanuals.com. All Manuals Search ANnd Download.
N-1
MetroSelect™
Custom Defaults
Metrologic manufatures several scanners for OEM applications. These scanners may use a different
set of defaults than Metrologic factory defaults. Scanning the bar code will reset the default table to
Metrologic defaults.
Enable Factory Defaults
846600
Scan this code followed by “Recall Defaults”
code to enable and load
Metrologic Factory Defaults.
Recall Defaults
999998
Download from Www.Somanuals.com. All Manuals Search And Download.
MetroSelect™
Ruby Verifone Defaults
RCH
84661280
84660010
Scan this code followed by “Recall
Defaults” code to enable and load
Ruby Verifone Defaults.
Scan this code followed by “Recall
Defaults” code to enable and load
RCH Defaults.
Sanyo
Gilbarco
84660020
84660030
Scan this code followed by “Recall
Defaults” code to enable and load
Gilbarco Defaults.
Scan this code followed by “Recall
Defaults” code to enable and load
Sanyo Defaults.
ALT Defaults
84660040
Scan this code followed by “Recall
Defaults” code to enable and load
Alt Defaults.
Download from Www.Somanuals.com. All Manuals Search NA-n2d Download.
N-3
MetroSelect™
Serial Program Mode
For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex).
To recall defaults:
1) Transmit <STX>999999<ETX> through the Serial Port. This will put the scanner in serial
program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex).
2) Transmit <STX>999998<ETX> through the Serial Port. This is the Recall Defaults bar code in the
MetroSelect guide. The scanner will respond with an ACK (06 Hex).
3) Transmit <STX>999999<ETX> through the Serial Port. This will cause the scanner to exit
program mode and save the new settings. The scanner will beep 3 times and send an
ACK (06 Hex).
If at anytime, the scanner cannot recognize a command, it will respond with a NAK (15 Hex).
Please refer to the Installation and User’s Guide of the scanner for a complete description of Serial
Program Mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
|