METROLOGIC INSTRUMENTS, INC.
IS6520/MS6520 Cubit® Series
Omnidirectional Bar Code Scanner
Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATIONS
Corporate Headquarters
North America
Metrologic Instruments, Inc.
90 Coles Road
Customer Service: 1-800-ID-METRO
Tel: 856-228-8100
Blackwood, NJ 08012-4683
Fax: 856-228-6673
Email: [email protected]
European Headquarters
Germany,
Middle East and Africa
Metrologic Instruments GmbH
Dornierstrasse 2
Tel: +49 89 89019 0
Fax: +49 89 89019 200
82178 Puchheim b.
Munich, Germany
Email: [email protected]
Germany Email: [email protected]
Spain
Metrologic Eria lbérica SL
Julián Camarillo 29, D-1
Edificio Diapasón
Tel: +34 913 272 400
Fax: +34 913 273 829
Email: [email protected]
28037 Madrid
Italy
Metrologic Instruments Italia srl
Via Emilia 70
40064 Ozzano dell’Emilia (BO)
Tel: +39 0 51 6511978
Fax: +39 0 51 6521337
Email: [email protected]
France
Metrologic Eria France SA
69 Rue de la Belle Etoile
ZI Paris Nord II, BP 50057
95947 – ROISSY CDG CEDEX
Tel: +33 (0) 1 48.63.78.78
Fax: +33 (0) 1 48.63.24.94
Email: [email protected]
United Kingdom Metrologic Instruments UK Limited
58 Tempus Business Centre
Tel: +44 (0) 1256 365900
Fax: +44 (0) 1256 365955
Email: [email protected]
Kingsclere Road, Basingstoke
Hampshire RG21 6XG
Russia
Metrologic Russia
Bolshaya Novodmitrovskaya 14
RU-125015
Tel: +7 095
Email: [email protected]
Moscow Russia
Asia
Singapore
China
Metrologic Asia (Pte) Ltd
No. 8 Kaki Bukit Place
4th Floor
Tel: 65-6842-7155
Fax: 65-6842-7166
Email: [email protected]
Singapore 416186
Metro (Suzhou) Technologies Co., Ltd. Tel: 86-512-62572511
221 Xing Hai Street
Suzhou Industrial Park
Suzhou, China
215021
Fax: 86-512-62571517
Email: [email protected]
Japan
Metrologic Japan Co., Ltd.
Matsunoya Building, 6 Floor
3-14-8 Higashiueno
Tel: 81-03-3839-8511
Fax: 81-03-3839-8519
Email: [email protected]
Taitou-Ku, Tokyo 110-0015 Japan
South America
Brazil
Metrologic do Brasil Ltda.
Rua da Paz 2059
Tel: 55-11-5182-8226
Fax: 55-11-5182-8315
CEP 04713-002
Email: [email protected]
Chácara Santo Antônio
São Paulo, SP, Brasil
Outside Brazil
Metrologic South America
Rua da Paz 2059
Tel: 55-11-5182-7273
Fax: 55-11-5182-7198
CEP 04713-002
Email: [email protected]
Chácara Santo Antônio
São Paulo, SP, Brasil
Copyright
© 2003 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any
means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Introduction................................................................................................1
Scanner and Accessories..........................................................................2
Installation
RS232, Light Pen (IS6520-41/MS6520-41) ...........................................3
Keyboard Wedge (IS6520-47/MS6520-47)............................................4
Stand Alone Keyboard (IS6520-47/MS6520-47)....................................5
Disconnecting the PowerLink Cable from the Scanner.............................6
Scanner Parts............................................................................................7
Mounting Holes .........................................................................................7
Stands .......................................................................................................8
Audible Indicators......................................................................................9
Failure Modes..........................................................................................10
Visual Indicators......................................................................................11
Programming Modes...............................................................................12
Labels......................................................................................................15
Maintenance............................................................................................15
Optimal Low and Close Depth of Field....................................................16
Optimal High and Normal Depth of Field ................................................17
Far Depth of Field....................................................................................18
Troubleshooting Guide............................................................................19
Appendix A
Design Specifications...........................................................................23
Appendix B
Default Settings....................................................................................25
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Appendix C
Scanner Pinout Connections ...............................................................29
Cable Connector Configurations..........................................................29
Appendix D
Warranty and Disclaimer .....................................................................31
Appendix E
Notices.................................................................................................32
Appendix F
Patents.................................................................................................34
Index........................................................................................................35
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Metrologic's Cubit® Series of compact omnidirectional bar code scanners
includes the MS6520 for retail applications and the IS6520 for OEM applications.
Both Cubit models have several key product features including:
•
•
•
•
•
•
Fully Automatic Scanning Operation
Single Cable Interface To Host
PowerLink Quick Disconnect User-Replaceable Cables
7 Beeper Tones
Programmable Depth Of Fields
Capable Of Scanning And Decoding All Standard Barcodes Including
Rss-14, RSS Limited And RSS Expanded Bar Codes
•
•
OPOS And JPOS System Compatible
Sunrise 2005 Compliant
The MS6520 is equipped with a tilt stand that can be mounted securely to the
countertop or wall for fixed -mount scanning. The multi-position stand has a
locking design that rotates the head of the MS6520 up to 64° making it perfect
for installation underneath check writing and credit card stands.
Since the IS6520 was designed to be part of an OEM product, it does not
include the tilt stand but instead is equipped with three (3) threaded mounting
holes on the back of the unit. The modular design of the IS6520 is versatile
enough for integration into a diversity of applications including kiosks, reverse
vending machines, time/attendance machines and price look-up systems.
A fixed vertical stand is also available for additional purchase. Please contact a
customer service representation at 1-800-ID-METRO for information.
SCANNER
INTERFACE
IS6520-41
or
Full RS232 and Light Pen Emulation
MS6520-41
IS6520-47
or
MS6520-47
Keyboard Wedge, Stand Alone Keyboard and
RS232 Transmit/Receive
1
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER AND ACCESSORIES
BASIC KIT COMPONENTS
Description
IS6520/MS6520 Cubit® Omnidirectional Scanning Engine
Part No.
00-02421
00-02407
Installation and User’s Guide*
MetroSelect® Configuration Guide*
OPTIONAL ACCESSORIES
Part No.
Description
AC to DC Power Transformer – Regulated 5.2VDC @ 650 mA output.
45-45593
120V United States
45-45591
45-45992
46-46803
46-46983
220V-240V Continental European
220V-240V United Kingdom
220V-240V Australia
220V-240V China
xxx - specifies connection to the host
PowerLink cable with built in power jack
2.7m (9’) coiled cord, long strain relief
53-53xxx
54-54xxx
PowerLink cable with built in power jack
2.1m (7’) straight cord, short strain relief
54-54002
54-54020
46-46486
46-46145
Keyboard Wedge PowerLink cable and Adapter Cable
Stand Alone Keyboard PowerLink Cable
Tilt Stand
Fixed Vertical Stand
To order additional items, contact the dealer, distributor or call Metrologic's
Customer Service Department at 1-800-ID-METRO (1-800-436-3876).
2
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
RS232, Light Pen (IS6520-41/MS6520-41)
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
PowerLink cable into the 10-pin socket
on Cubit. You will hear a ‘click’ when
the connection is made.
3. Connect the 9-pin female end of the
PowerLink cable to the host device.
Note: Skip to step 6 if receiving power
from the host device.
4. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC
outlet. The outlet must be
located near the equipment and
be easily accessible.
5. Connect AC power to the transformer.
6. Turn on the host device.
Plugging the scanner into a port on the host system does not
guarantee that scanned information will be communicated properly to
the host system. The scanner is shipped from the factory configured
to a set of default parameters. Please refer to the MetroSelect
Configuration Guide (MLPN 00-02407) for instructions on changing the
scanner’s configuration. In addition, please check that the scanner
and host system are using the same communication protocol.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950,
the power source should meet applicable performance requirements for a limited power
source.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Keyboard Wedge (IS6520-47/MS6520-47)
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
PowerLink cable into the 10-pin socket
on Cubit. You will hear a ‘click’ when
the connection is made.
3. Disconnect the keyboard from the host
device.
4. Connect the “Y” end of the PowerLink
cable to the keyboard and the keyboard
port on the host device. If necessary
use the male/female adapter cable
supplied with the scanner to make the
proper connections.
5. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC
outlet. The outlet must be
located near the equipment and
be easily accessible.
6. Connect AC power to the transformer.
7. Turn on the host device.
Powering the Cubit directly from the host device can sometimes
cause interference with the operation of the scanner or the computer.
Not all computers supply the same current through the keyboard port.
For this reason, Metrologic recommends using an external power
supply. For additional information contact a Metrologic customer
service representative.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950,
the power source should meet applicable performance requirements for a limited power
source.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Stand Alone Keyboard (IS6520-47/MS6520-47)
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
PowerLink cable into the 10-pin socket
on Cubit. You will hear a ‘click’ when
the connection is made.
3. Connect the other end of the PowerLink
cable to the keyboard port on the host
device.
4. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC
outlet. The outlet must be
located near the equipment and
be easily accessible.
5. Connect AC power to the transformer.
6. Turn on the host device.
Powering the Cubit directly from the host device can sometimes
cause interference with the operation of the scanner or the computer.
Not all computers supply the same current through the keyboard port.
For this reason, Metrologic recommends using an external power
supply. For additional information contact a Metrologic customer
service representative.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950,
the power source should meet applicable performance requirements for a limited power
source.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DISCONNECTING THE POWERLINK CABLES FROM THE SCANNER
Before removing the cable from the scanner, Metrologic recommends that the
power on the host system is off and the power supply has been disconnected
from the PowerLink cable.
&
o p
q
n
1. Locate the small ‘pin-hole’ on the back of the scanner.
2. Bend an ordinary paperclip into the shape shown above.
3. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
4. You will here a faint ‘click’. Pull gently on the strain-relief of the PowerLink
cable and it will slide out of the scanner.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER PARTS
A. Speaker
Serves as an audible indicator.
B. Green & Red LEDs
During normal operation, the green
LED is on. This indicates that the
laser is on and the unit is ready to
scan. On a successful read of a bar
code, the red LED will turn on.
After communication to the host is
complete, the red LED will turn off.
The LEDs are also used as
C
diagnostic indicators and mode
indicators.
B
C. Output Window
A
Laser light emits form this aperture.
D
D. PowerLink Cable
The IS6520/MS6520 scanner has a
10-pin modular jack. The 10-pin
modular plug on the PowerLink
cable connects into the
IS6520/MS6520.
MOUNTING HOLES
Each IS6520/MS6520 Cubit® is
equipped with three threaded mounting
holes located on the back of the
scanner. The following diagram shows
the exact location of each mounting
hole. The mounting holes are 6
millimeters deep and are threaded for
use with 3 millimeter screws.
Caution: Using a screw that is longer
than 6 millimeters can
potentially damage the
scanner.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
STANDS
Fixed Vertical Stand (MLPN 46-46145)
e.
d.
Optional purchase.
a. Fixed Vertical Stand ........ Qty. 1
b. #7 x 1.00” Wood Screw ... Qty. 3
c. M3 x 0.5 x 6 mm Screw... Qty. 3
Tilt Stand (MLPN 46-46486)
Shipped with the MS6520 only.
a.
c.
b.
c. Tilt Stand.......................... Qty. 1
d. #8 x 1.00” Wood Screw ... Qty. 3
Fixed Vertical Stand Installation (MLPN 46-46145)
Step 1: Drill three #43 pilot holes in the
countertop.
Step 2: Attach the stand to the countertop
with the three
#7 wood screws provided.
Step 3: Attach the scanner to the stand
with the three M3 screws provided.
Tilt Stand Installation (MLPN 46-46486)
Step 1: Drill three #39 pilot holes in the
countertop.
Step 2: Insert the scanner into the rubber
boot (the MS6520 is shipped
assembled).
Step 3: Tilt the scanner forward in the
stand.
Step 4: Attach the stand to the countertop
using the three
#8 wood screws provided.
Step 5: Tilt the scanner back into place.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
AUDIBLE INDICATORS
When the IS6520/MS6520 scanner is in operation, it provides audible feedback.
These sounds indicate the status of the scanner. Eight settings are available for
the tone of the beep (normal, 6 alternate tones and no tone). To change the
tone, refer to the MetroSelect Configuration Guide (MLPN 00-02407).
One Beep
When the scanner first receives power, the green LED will
turn on, then the red LED will flash and the scanner will
beep once. (The red LED will remain on for the duration of
the beep.) The scanner is ready to scan.
When the scanner successfully reads a bar code, the red
LED will flash and the scanner beeps once (if programmed
to do so). If the scanner does not beep once and the red
light does not flash, then the bar code has not been
successfully read.
Razzberry Tone
This tone is a failure indicator. Refer to “Failure
Modes" page 10.
Three Beeps - During Operation
During operation of the scanner, the red LED will flash
while the scanner simultaneously beeps three times (while
going into programming mode).
The red LED will continue to flash until the unit exits
program mode. Upon exiting program mode, the scanner
will beep three times and the red LED will stop flashing.
When configured, 3 beeps can also indicate a
communications timeout during normal scanning mode.
When using one-code-programming, the scanner will beep
three times (the current selected tone), followed by a short
pause then by a high tone and a low tone. This tells the
user that the single configuration bar code has successfully
configured the scanner.
Three Beeps - On Power Up
This is a failure indicator. Refer to “Failure Modes” on
page 10.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
FAILURE MODES
Flashing Green and One Razzberry Tone
This indicates the scanner has experienced a laser
subsystem failure. Return the unit for repair at an
authorized service center.
Flashing Green and Red and Two Razzberry
Tones
This indicates the scanner has experienced a motor failure.
Return the unit for repair at an authorized service center.
Continuous Razzberry Tone with Both LEDs Off
If, upon power up, the scanner emits a continuous razzberry
tone, then the scanner has an electronic failure. Return the
unit for repair at an authorized service center.
Three Beeps - On Power Up
If the scanner beeps 3 times on power up then, the non-
volatile memory that holds the scanner configuration has
failed. Return the unit for repair at an authorized service
center.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
VISUAL INDICATORS
There is a red LED and a green LED on IS6520/MS6520. When the scanner is
on, the flashing or stationary, activity of the LEDs indicates the status of the
current scan and the scanner.
No Red or Green LED
The LEDs will not be illuminated if the scanner is not receiving
power from the host or transformer.
Steady Green
When the laser is active, the green LED is illuminated. The
green LED will remain illuminated until the laser is deactivated.
During the power save mode, the laser will turn on and turn off.
During this period, the green LED remains illuminated.
Steady Green and Single Red Flash
When the scanner successfully reads a bar code, the red LED
will flash and the scanner will beep once. If the red LED does not
flash or the scanner does not beep once, then the bar code has
not been successfully read.
Steady Green and Steady Red
After a successful scan, the scanner transmits the data to the
host device. Some communication modes require that the host
inform the scanner when data is ready to be received. If the host
is not ready to accept the information, the scanner's red LED will
remain on until the data can be transmitted.
Steady Green and Flashing Red
This indicates the scanner is in program mode. A razzberry tone
indicates that an invalid bar code has been scanned in this mode.
Steady Red, Green Off
This indicates the scanner may be waiting for communication
from the host.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING MODES
The IS6520/MS6520 Cubit has 3 modes of programming.
Bar Codes: Cubit can be configured by scanning the bar codes located in the
MetroSelect Configuration Guide (MLPN 00-02407). Please refer to this guide for
instructions. This manual can be downloaded for FREE from Metrologic’s
website (www.metrologic.com).
MetroSet®: This user-friendly Windows-based configuration program allows you
to simply ‘point-and-click’ at the desired scanner options. This program can be
disks can be ordered by calling 1-800-ID-METRO.
Serial Programming: This mode of programming is ideal for OEM applications.
This mode gives the end-user the ability to send a series of commands using the
serial port of the host system. The commands are equivalent to the numerical
values of the bar codes located in the MetroSelect Configuration Guide.
How does Serial Programming work?
1. Each command sent to the scanner is the ASCII representation of each
numeral in the configuration bar code. The entire numeric string is framed
with an ASCII [stx] and an ASCII [etx].
EXAMPLE #1: Command for Disabling Codabar
Command = [stx]100104[etx]
String Sent to Scanner = 02h 31h 30h 30h 31h 30h 34h 03h
(All values are hexadecimal).
2. If the command sent to the scanner is valid, the scanner will respond with
an [ack].
3. If the command sent to the scanner in invalid, the scanner will respond with
a [nak].
NOTE: If this occurs, the end-user must start over at the very beginning of
the configuration sequence. Simply re-tranmsitting the invalid
command will not work, you must start over.
4. During programming, the motor and laser remain active. YOU CANNOT
SCAN ANY BAR CODES WHILE IN PROGRAM MODE.
5. There is a 20 second window between commands. If a 20 second timeout
occurs, the scanner will send a [nak] and you must start over.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING MODES (CONTINUED)
6. To enter serial program mode, send the following command [stx]999999[etx].
7. To exit serial program mode, send the following command [stx]999999[etx],
the scanner will respond with an [ack] and a long beep.
8. This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits
settings that are configured in the scanner. The default settings of the
scanner are 9600, Space, 2, 7 respectively. If a command is sent to the
scanner to change any of these settings, the change will NOT take effect
until after serial program mode is exited.
EXAMPLE #2: The following example will set the scanner to the factory
default settings, Disable Scanning of Code 128 bar codes, change the
beeper tone, and add a “G” as a programmable prefix.
HOST
SCANNER
RESPONSE
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
FEATURE
COMMAND
[stx]999999[etx]
[stx]999998[etx]
[stx]100113[etx]
[stx]318565[etx]
[stx]903500[etx]
[stx]0[etx]
ASCII REPRESENTATION
02h 39h 39h 39h 39h 39h 39h 03h
02h 39h 39h 39h 39h 39h 38h 03h
02h 31h 30h 30h 31h 31h 33h 03h
02h 33h 31h 38h 35h 36h 35h 03h
02h 39h 30h 33h 35h 30h 30h 03h
02h 30h 03h
Enter Program Mode
Load Defaults
Disable Code 128
Alternate Tone 1
Prog. Prefix #1
Code Byte 0
Code Byte 7
[stx]7[etx]
02h 37h 03h
Code Byte 1
[stx]1[etx]
02h 31h 03h
Exit Program Mode
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
The scanner will emit a long beep!
The commands sent to the scanner do not include the small superscripted ‘3’
that you see in front of each bar code string in the MetroSelect® manual.
THE ‘3’ SHOULD NOT BE SENT, IT IS A CODE TYPE DESIGNATION
ONLY!
As you will note for commands requiring additional bar codes to be scanned
(such as prefixes, suffixes, timeouts, etc.), simply send the code bytes in the
same order that you would normally scan the bar codes.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING MODES (CONTINUED)
EXAMPLE #3: The following example shows the events that occur when an
invalid bar code is sent. This sample will load the factory default settings
and then set the baud rate to 19200.
HOST
SCANNER
RESPONSE
[ack] or 06h
[nak] or 15h
FEATURE
COMMAND
ASCII REPRESENTATION
Enter Program Mode [stx]999999[etx]
Load Defaults [stx]99999:[etx]
02h 39h 39h 39h 39h 39h 39h 03h
02h 39h 39h 39h 39h 39h 3Ah 03h
Invalid command was sent, you must start over!
Enter Program Mode [stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
02h 39h 39h 39h 39h 39h 39h 03h
02h 34h 31h 35h 38h 37h 30h 03h
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
Load Defaults
[stx]999998[etx]
[stx]415870[etx]
[stx]999999[etx]
19200 Baud Rate
Exit Program Mode
The scanner will emit a long beep!
This example illustrates 2 important points.
First, if an invalid command is sent from the host, the scanner responds with
a [nak] and the end-user must start over from the beginning.
Second, if a command is sent to change the Baud Rate, the new baud rate
does not take effect until after the end-user exits program mode.
ABREVIATED ASCII TABLE
Character
Hex Value
02h
Decimal Value
[STX]
2
[ETX]
03h
3
[ACK]
06h
6
[NAK]
15h
21
48
49
50
51
52
53
54
55
56
57
0
1
2
3
4
5
6
7
8
9
30h
31h
32h
33h
34h
35h
36h
37h
38h
39h
14
Download from Www.Somanuals.com. All Manuals Search And Download.
LABELS
Each scanner has a label on the back of the unit that lists the model number,
date of manufacture, serial number, CE and caution information. The following
is an example of the label:
MAINTENANCE
Smudges and dirt can interfere with the proper scanning of a bar code.
Therefore, the output window will need occasional cleaning.
1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth.
2. Gently wipe the scanner window.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
OPTIMAL LOW AND CLOSE DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm)
123
250
225
200
105
95
175
150
DISTANCE:
SCANNER FACE
TO BAR CODE (mm)
J
125
100
82
H
73
G
D
75
50
B
49
45
40
25
0
Minimum Bar Code Element Width
A
-
B
C
D
E
F
G
H
J
K
-
mm
.15
5.7
-
.17
6.8
-
-
.25 .33 .53
10 13 21
mils
-
-
-
-
-
Note: The same depth of field is achieved when programming Cubit® for
either Optimal Low Depth of Field or Close Depth of Field.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OPTIMAL HIGH AND NORMAL DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm)
250
123
225
200
175
150
105
95
DISTANCE:
SCANNER FACE
TO BAR CODE (mm)
J
125
100
75
50
25
0
82
H
G
73
68
D
B
58
49
45
Minimum Bar Code Element Width
A
B
C
D
E
F
G
H
J
K
-
mm
-
-
.15
5.7
-
.17
6.8
-
-
.25 .33 .53
10 13 21
mils
-
-
-
-
Note: The same depth of field is achieved when programming Cubit® for
either Optimal High Depth of Field or Normal Depth of Field.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
FAR DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm)
250
225
200
175
150
123
114
J
105
H
95
91
DISTANCE:
SCANNER FACE
TO BAR CODE (mm)
125
100
75
50
25
0
G
82
77
73
D
B
49
45
Minimum Bar Code Element Width
A
B
C
D
E
F
G
H
J
K
-
mm
-
-
.15
5.7
-
.17
6.8
-
-
.25 .33 .53
10 13 21
mils
-
-
-
-
18
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited
warranty terms.
All Interfaces
IS6520/MS6520 Series Troubleshooting Guide
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
No LEDs, beep No power is being
Check transformer, outlet and
power strip. Make sure the cable
is plugged in to the scanner
or motor spin
supplied to the
scanner
No LEDs, beep No power is being
supplied to the
Some host system’s cannot
supply enough current to power
Omni-Quest. Use the power
supply included with the scanner.
scanner front host
3 beeps on
power up
Non-volatile RAM
failure
Contact a Metrologic
Representative, if the unit will not
hold the programmed
configuration
Continuous
razz tone on
power up
RAM or ROM failure
VLD failure
Contact a Metrologic
Representative, if the unit will not
function
Razz tone and
green LED
flash at power
up
Contact a Metrologic
Representative
Razz tone and
both LEDs
flash at power
up
Scanner motor failure
Contact a Metrologic
Representative
Unit scans,
Communicates set too short
Same symbol timeout
Adjust same symbol timeout for a
longer time
and beeps
twice
19
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE (CONTINUED)
All Interfaces
IS6520/MS6520 Series Troubleshooting Guide (continued)
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
The unit
Beeper disabled. No
Enable beeper. Select tone
powers up, but tone selected
does not
scan and/or
beep
The unit
Scanning a particular
UPC/EAN, Code 39, interleaved
2 of 5, Code 93, Code 128 and
Codabar are enabled by default.
Verify that the type of bar code
being read has been selected
powers up, but symbology that is not
does not scan
and/or beep
enabled
The unit
The scanner has been
Verify that the bar code that is
being scanned falls into the
powers up, but programmed for a
does not scan
and/or beep
character length lock, or criteria. (Typical of Non-
a minimum length and
UPC/EAN codes.) (The scanner
bar code being scanned defaults to a minimum of 4
does not satisfy the
programmed criteria
character bar code)
The unit scans The scanner is
a bar code, but configured to support
If the scanner is setup to support
ACK/NAK, RTS/CTS,
locks up after
the first scan
(red LED stays receiving the signal
on)
some form of host
handshaking but is not
XON/XOFF or D/E, verify that
the host cable and host are
supporting the handshaking
properly
The unit scans, The scanner's data
Verify that the scanner's data
format matches that required by
the host. Make sure that the
scanner is connected to the
proper host port
but the data
transmitted to
the host is
incorrect
format does not match
the host system
requirements
20
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE (CONTINUED)
All Interfaces
IS6520/MS6520 Series Troubleshooting Guide (continued)
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
Scanner beeps
at some bar
codes and NOT
for others of the
same bar code
symbology
The print quality of the
bar code is suspect
Check print mode. The type of
printer could be the problem.
Change print settings. For
example change to econo mode
or high speed
The aspect ratio of the
bar code is out of
tolerance
Scanner beeps
at some bar
codes and NOT
for others of the
same bar code
symbology
Check print mode. The type of
printer could be the problem.
Change print settings, ie change
to econo mode or high speed
The bar code may
have been printed
incorrectly
Scanner beeps
at some bar
codes and NOT
for others of the
same bar code
symbology
Check if it is a check digit,
character, or border problem
Scanner beeps
at some bar
The scanner is not
configured correctly for properly
Check if check digits are set
codes and NOT this type of bar code
for others of the
same bar code
symbology
Scanner beeps
at some bar
The minimum symbol
length setting does not
Check if the correct minimum
symbol length is set
codes and NOT work with the bar code
for others of the
same bar code
symbology
21
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE (CONTINUED)
RS232 only
IS6520/MS6520 Series Troubleshooting Guide (continued)
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
Powers up OK
and scans OK
but does not
communicate
properly to the
host
Com port at the host is Check to make sure that the
not working or
baud rate, data bits, stops bits
and parity of the scanner and
the communication port match
and the program is looking for
"RS232" data
configured properly
Powers up OK
and scans OK
but does not
communicate
properly to the
host
Cable not connected to Check to make sure that the
the proper com port
baud rate, data bits, stops bits
and parity of the scanner and
the communication port match
and the program is looking for
"RS232" data
Powers up OK
and scans OK
but does not
communicate
properly to the
host
Com port not operating Check to make sure that the
properly
baud rate, data bits, stops bits
and parity of the scanner and
the communication port match
and the program is looking for
"RS232" data
The host is
receiving data
but the data
does not look
correct
The scanner and host
may not be configured
for the same interface
font
Check that the scanner and the
host are configured for the same
interface font
Characters are
being dropped
Intercharacter delay
needs to be added to
the transmitted output
Add some Intercharacter delay to
the transmitted output by using
the MetroSelect Configuration
Guide (mlpn 00-02407)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A
Design Specifications
Operational
Light Source:
VLD 650 ± 10 nm, 0.681 milliwatts (PEAK)
0 mm to 176 mm (0” to 7”) for 0.33 mm
(13 mil) bar code at default setting
(programmable)
Depth of Field:
Scan Speed:
1000 scan lines/second
Scan Pattern:
Scan Lines:
5 fields of 4 parallel lines (omnidirectional)
20
Min Bar Width:
Decode capability:
0.145 mm (5.7 mil)
Autodiscriminates all standard bar codes; for
other symbologies call Metrologic
RS-232, Light Pen Emulation, Keyboard Wedge,
Stand Alone Keyboard
System Interfaces:
Print Contrast:
Roll, Pitch, Yaw:
Indicators:
35% minimum reflectance difference
360°, 60° ,60°
Green = laser on, ready to scan;
Red = good read, decoding
7 tones or no beep
Beeper Operation:
Mechanical
Length:
102 mm (4.0")
Width:
83 mm (3.25")
Height (front edge):
Height (back edge):
Weight:
70 mm (2.75")
55 mm (2.25")
298 g (10.5 oz)
Termination:
Mounting Holes:
10 Position Modular RJ45
3 mm threaded; maximum depth of
6 mm (0.24”)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A (CONTINUED)
Design Specifications
Electrical
Power:
1.0 W
Input Voltage:
Operating Current:
DC Transformers:
EMC:
5 VDC ± 0.25 V
200 mA typical @5VDC
Class 2; 5.2 VDC @ 650 mA
FCC, ICES-003 & EN 55022 Class A
CDRH Class IIa
Laser Class:
EN 60825-1:1994/A11: 1996 CLASS 1
Environmental
Operating Temperature:
Storage Temperature:
Humidity:
-20°C to 40°C (-4°F to 104°F)
-40°C to 60°C (-40°F to 140°F)
5% to 95% relative humidity, non-condensing
Up to 4840 Lux (450 footcandles)
Sealed to resist airborne particulate contaminants
None required
Light Levels:
Contaminants:
Ventilation:
Specifications subject to change without notice.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B
Default Settings
Many functions of the scanner can be "programmed" - that is, enabled or
disabled. The scanner is shipped from the factory programmed to a set of
default conditions. The default parameter of the scanner has an asterisk (*) in
the charts on the following pages. If an asterisk is not in the default column then
the default setting is Off or Disabled. Every communication does not support
every parameter. If the communication supports a parameter listed in the charts
on the following pages, a check mark will appear.
Light
Pen
Parameter
Default RS232*
KBW
UPC/EAN
Code 128
Code 93
Codabar
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
*
*
*
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Interleaved 2 of 5 (ITF)
MOD 10 Check on ITF
Code 11
*
*
Code 39
Full ASCII Code 39
MOD 43 Check on Code 39
MSI-Plessey
MSI-Plessey, 10/10 Check Digit
MSI-Plessey, MOD 10 Check Digit
Paraf Support
*
ITF Symbol Lengths
Minimum Symbol Length
Symbol Length Lock
Bars High as Code 39
Spaces High as Code 39
Bars High as Scanned
Spaces High as Scanned
DTS/SIEMENS
Variable
4
None
*
25
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B (CONTINUED)
Light
Pen
Parameter
Default RS232*
KBW
DTS/NIXDORF
NCR F
*
NCR S
Poll Light Pen Source
Beeper Tone
9
9
Normal
9
9
9
9
Before
Transmit
Beep/Transmit Sequence
9
Communication Timeout
Razzberry Tone on Timeout
Three Beeps on Timeout
No Beeps on Timeout
None
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
*
Enter Power Save Mode
10 mins.
Same Symbol Rescan
Timeout: 200 msecs
9
9
9
Same Symbol Rescan
Timeout: 500 msecs
Programmable in 50 msec steps
(MAX 6.35 seconds)
9
9
9
*
Same Symbol Rescan
Timeout: 1250 msecs
9
9
9
9
9
9
Same Symbol Rescan
Timeout: 2000 msecs
1 msecs
10 msecs
in KBW
Intercharacter Delay Programmable in
1 msec steps (MAX 255 msecs)
9
9
Number of Scan Buffers
1
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Transmit UPC-A Check Digit
Transmit UPC-E Check Digit
Expand UPC-E
*
Convert UPC-A to EAN-13
Transmit Lead Zero on UPC-E
Convert EAN-8 to EAN-13
Transmit UPC-A Number System
9
9
*
26
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B (CONTINUED)
Light
Pen
Parameter
Default
RS232*
KBW
Transmit UPC-A Manufacturer ID#
Transmit UPC-A Item ID#
Transmit Codabar Start/Stop Characters
CLSI Editing (Enable)
Transmit Mod 43 Check Digit on Code 39
Transmit Code 39 Stop/Start Characters
Transmit Mod 10/ITF
Transmit MSI-Plessey Check Characters
Parity
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
*
*
Space
9600
Baud Rate
8 Data Bits
7 Data Bits
*
Transmit Sanyo ID Characters
Nixdorf ID
9
9
9
9
9
9
9
9
9
9
9
9
LRC Enabled
UPC Prefix
UPC Suffix
Transmit AIM ID Characters
STX Prefix
ETX Suffix
Carriage Return
*
*
Line Feed
Tab Prefix
Tab Suffix
“DE” Disable Command
“FL” Laser Enable Command
DTR Handshaking Support
RTS/CTS Handshaking
Character RTS/CTS
*
27
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B (CONTINUED)
Light
Pen
Parameter
Default
RS232*
KBW
Message RTS/CTS
9
9
9
9
9
9
9
9
9
9
XON/XOFF Handshaking
ACK/NA K
Two Digit Supplements
Five Digit Supplements
Bookland
as code 39
9
9
9
9
9
9
9
as code 39
as code 39
977 (2 digit) Supplemental Requirement
Supplements are not Required
Two Digit Redundancy
Five Digit Redundancy
9
9
9
9
*
*
100 msec to Find Supplement
Programmable in 100 msec steps
(MAX 800 msec)
9
9
9
*
Coupon Code 128
as code 39
9
9
9
9
9
9
Programmable Code Lengths
Programmable Prefix Characters
Suffix Characters
7 avail.
9
10 avail.
Prefixes for individual Code Types
Editing
9
9
9
9
9
Inter Scan-Code Delay
Programmable (100 msec steps)
800 msec
Function/Control Key Support
Minimum Element Width
Programmable in 5.6 µsec steps
1 msec
Depth of Field
Optimal High Depth of Field
Normal Depth of Field
Optimal Low Depth of Field
Close Depth of Field
Far Depth of Field
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
*
28
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C
Scanner Pinout Connections
1
10
The IS6520/MS6520 scanner interfaces terminate
to a 10-pin modular jack. The serial # label
indicates the interface enabled when the scanner
is shipped from the factory.
IS6520-47 / MS6520-47
IS6520-41 / MS6520-41
Keyboard Wedge
RS-232/LTPN
Pin
1
Function
Pin
1
Function
Ground
Ground
2
3
4
RS-232 Transmit Output
RS-232 Receive Input
PC Data
2
3
4
RS-232 Transmit Output
RS-232 Receive Input
RTS Output
5
PC Clock
5
CTS Input
6
7
KB Clock
PC +5V
6
7
DTR Input/LTPN Source
Reserved
8
KB Data
8
LTPN Data
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground
Cable Connector Configurations
“Standard” PowerLink cable
(MLPN 53000 or 54000)
9
5
9-pin D-type female connector to the PC
Pin
Function
1
2
3
4
5
6
7
8
9
Shield Ground
RS-232 Transmit Output
RS-232 Receive Input
DTR Input
Power/Signal Ground
Light Pen Data
CTS Input
6
1
9-Pin D-Type Connector
RTS Output
+5VDC*
* If a PowerLink power supply is plugged into the PowerLink cable, +5V
will NOT be available on this pin. This pin is used when the host is
supplying +5V to the scanner.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C (CONTINUED)
Keyboard Wedge Powerlink and Adapter Cable (MLPN 54-54008)
The Keyboard Wedge PowerLink cable is terminated with a 5-pin DIN female
connector on one end, and a 6-pin mini DIN male on the other.
2
5
4
2
1
1
3
4
3
6
5
Keyboard Wedge
PowerLink Cable
5-Pin DIN, Female
6-Pin DIN, Male
Metrologic will supply an adapter cable with a 5-pin DIN male connector on one
end and a 6-pin mini DIN female connector on the other.
2
4
5
1
2
3
1
3
4
5
6
Adapter Cable
5-Pin Din, Male
6-pin Mini Din, Female
According to the termination required, connect the appropriate end of the adapter
cable to the PowerLink cable, leaving the necessary termination exposed for
connecting to the keyboard and the keyboard port on the PC.
The pin assignments are as follows:
PowerLink Cable
Adapter Cable
5-pin Female DIN
Function
5-pin Male DIN
Function
Pin
1
Pin
1
Keyboard Clock
Keyboard Data
No Connect
PC Clock
2
2
PC Data
3
3
No Connect
Power Ground
+5 Volts DC
4
Power Ground
+5 Volts DC
4
5
5
6-pin Male Mini-DIN
6-pin Female Mini-DIN
Pin
1
Function
PC Data
Pin
1
Function
Keyboard Data
No Connect
2
No Connect
Power Ground
+5 Volts DC
PC Clock
2
3
3
Power Ground
+5 Volts DC
4
4
5
5
Keyboard Clock
No Connect
6
No Connect
6
30
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX D
Warranty and Disclaimer
Limited Warranty
The IS6520/MS6520 Cubit® scanners are manufactured by Metrologic at its
Blackwood, New Jersey, U.S.A. facility. The IS6520/MS6520 Cubit® scanners
have a two (2) year limited warranty from the date of manufacture. Metrologic
warrants and represents that all IS6520/MS6520 Cubit® scanners are free of all
defects in material, workmanship and design, and have been produced and
labeled in compliance with all applicable U.S. Federal, state and local laws,
regulations and ordinances pertaining to their production and labeling.
This warranty is limited to repair, replacement of Product or refund of Product
price at the sole discretion of Metrologic. Faulty equipment must be returned to
the Metrologic facility in Blackwood, New Jersey, U.S.A. or Puchheim, Germany.
To do this, contact Metrologic’s Customer Service/Repair Department to obtain a
Returned Material Authorization (RMA) number.
In the event that it is determined the equipment failure is covered under this
warranty, Metrologic shall, at its sole option, repair the Product or replace the
Product with a functionally equivalent unit and return such repaired or replaced
Product without charge for service or return freight, whether distributor,
dealer/reseller, or retail consumer, or refund an amount equal to the original
purchase price.
This limited warranty does not extend to any Product which, in the sole
judgement of Metrologic, has been subjected to abuse, misuse, neglect,
improper installation, or accident, nor any damage due to use or misuse
produced from integration of the Product into any mechanical, electrical or
computer system. The warranty is void if the case of Product is opened by
anyone other than Metrologic’s repair department or authorized repair centers.
THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR
GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR
CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU
OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR
ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO
PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES
OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN
THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE
ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES
THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.
Metrologic Instruments, Inc.
90 Coles Road
Metrologic Instruments GmbH
Dornierstrasse 2
Blackwood, NJ 08012-4683
Customer Service Department:
1-800-ID-METRO (1-800-436-3876)
TEL: 856-228-8100
82178 Puchheim b
Munich, Germany
TEL: 49-89-89019-0
FAX: 49-89-89019-200
FAX: 856-228-6673
31
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX E
Notices
Notice
This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at his own expense. Any unauthorized changes or modifications to
this equipment could void the users authority to operate this device.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Notice
This Class A digital apparatus complies with Canadian ICES-003.
Remarque
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Caution
Use of controls or adjustments or performance of procedures other than those specified herein may result
in hazardous laser light exposure. Under no circumstances should the customer attempt to service the
laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser
light exposure. The use of optical instruments with the laser equipment will increase eye hazard.
Atención
La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los
especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario
deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando
este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede
conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser
puede incrementar el riesgo para la vista.
Attention
L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves
irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne
regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez
jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement
laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque
d'endommagement de la vision.
Achtung
Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann
eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den
Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß
der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie
dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte
mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.
Attenzione
L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente
Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente
tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che
lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo
potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi
laser, aumenta il rischio di danni alla vista.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX E (CONTINUED)
European Standard
Warning
This is a class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
Funkstöreigenschaften nach EN 55022:1998
Warnung!
Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im
Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber
verlangt werden, angemessene Maßnahmen durchführen.
Standard Europeo
Attenzione
Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private
potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore
opportune misure.
Attention
Ce produit est de classe “A”. Dans un environnement domestique, ce produit
peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être
amené à predre les mesures adéquates.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX F
Patents
35
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
A
F
AC input/outlet.............2, 3, 4, 5, 29
Accessories...................................2
Approvals ........................15, 32, 33
Assignments
pin ...........................................29
Audible ..........................................9
Autodiscriminates........................23
Failure indicator(s)........................ 9
Failure modes......................... 9, 10
G
Green LED............................ 11, 19
H
B
Host .............. 2, 3, 6, 11, 20, 22, 29
Bar code1, 9, 11, 12, 15, 16, 17,
18, 20, 21, 25
Bar width .....................................23
Beep..........9, 10, 11, 19, 20, 21, 26
I
Indicators .................... 9, 10, 11, 23
audible ...................................... 9
LED............... 7, 9, 10, 11, 19, 20
Visual...................................... 11
Input voltage ............................... 24
Installation............................. 3, 7, 8
Interfaces.............. 1, 19, 20, 21, 23
C
Cable.................................2, 22, 30
communication..................29, 30
detachable.................1, 6, 29, 30
pin assignments ................29, 30
powerlink .................3, 4, 5, 6, 30
Caution............3, 4, 5, 7, 15, 32, 33
CDRH..........................................24
CE................................................32
Communication ...........3, 11, 22, 25
Compliance ...........................32, 33
Current ..............................9, 19, 24
Customer service ....................2, 31
K
Keyboard wedge........... 1, 2, 29, 30
L
Labels ......................................... 15
Light levels.................................. 24
Light Pen......... 1, 23, 25, 26, 27, 28
Light source ................................ 23
List ................................................ 2
D
DC transformer............................24
Decode capability........................23
Default settings .........25, 26, 27, 28
Depth of field.......16, 17, 18, 23, 28
Design specifications ..................23
Disclaimer ...................................31
M
Maintenance ............................... 15
N
E
Notices.................................. 32, 33
Electrical......................................24
35
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
S
O
Scan lines ................................... 23
Scan pattern................................ 23
Scan speed................................. 23
Service.............................. 2, 10, 31
Specifications........................ 23, 24
System interfaces ....................... 23
Operating current ........................24
Operating temperture ..................24
Operation...........................9, 23, 32
Operational..................................23
Output window...............................7
P
T
Parts..........................................2, 7
PC .................................................4
Port..........................................5, 22
Power supply...................1, 2, 5, 29
Powerlink...........................2, 3, 4, 6
Programming guide .............3, 9, 12
Programming modes .......12, 13, 14
Termination............................. 5, 23
Tones................................ 9, 10, 23
Transformers............................... 24
Troubleshooting ........ 19, 20, 21, 22
V
Ventilation ................................... 24
Visual .......................................... 11
Voltage........................................ 24
Q
Quick start .....................................3
W
R
Warranty ............................... 19, 31
Weight......................................... 23
Window ................................... 7, 15
Razzberry tone............9, 10, 11, 26
Red LED............................9, 11, 20
Repair..........................................10
RMA ............................................31
RS-232 ..........22, 23, 25, 26, 27, 28
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
July 2004
Printed in the USA
0 0 - 0 2 4 2 1 B
Download from Www.Somanuals.com. All Manuals Search And Download.
|